Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros

Tipo de documento
Intervalo de ano de publicação
1.
Sleep Breath ; 24(4): 1487-1494, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-31916123

RESUMO

OBJECTIVE: Due to the increasing prevalence of obstructive sleep apnea (OSA), more practical diagnostic methods than polysomnography (PSG) have become necessary. This research aims to analyze the performance of nocturnal oximetry (NO) in the diagnosis of OSA. METHODS: In this cross-sectional study, we analyzed 41 variables provided by the oximetry of all PSG performed by the LabSono of University Hospital Gaffrée and Guinle, a total of 83 exams. We evaluated the correlation coefficients (Spearman) between these data and the Apnea/Hypopnea Index (AHI) and then calculated the diagnostics performances, by the area under the curve (ROC) (AUC), of the best correlated variables and their respective cutoffs, in the identification of an AHI ≥ 15/h. RESULTS: Virtually all oximetric data showed good correlations with AHI, except for some temporal data. We chose 5 of them and calculated their diagnostic performances. T < 90% shows AUC of 0.904 (0.835-0.972) and, at cutoff > 19 min, a sensitivity (Sens.) of 75.68% and specificity (Spec.) of 95.65%. DO3/10Total, AUC 0.936 (0.888-0.989), and at the cutoff > 51 has Sens. 97.3% and Spec. 76.09%. ODI3/10/h has AUC 0.932 (0.884-0.988), at the cutoff > 7/h, Sens. 97.3% and Spec. 78.26%. DO4/5Total AUC 0.932 (0.882-0.981), at the cutoff > 64 has Sens. 86.49% and Spec. 82.61% and ODI4/5/h has AUC 0.930 (0.880-0.981), the cutoff > 5.69/h Sens. 97.3% and Spec. 73.91%. CONCLUSIONS: Our study concludes that NO is accurate in identifying AHI > 15/h, and provides reliable information on PSG replacement, which could make the diagnosis of OSA cheaper and more comfortable.


Assuntos
Oximetria/métodos , Apneia Obstrutiva do Sono/diagnóstico , Adulto , Brasil , Estudos Transversais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Prognóstico , Curva ROC , Apneia Obstrutiva do Sono/epidemiologia
2.
Arq Neuropsiquiatr ; 76(3): 177-182, 2018 03.
Artigo em Inglês | MEDLINE | ID: mdl-29809230

RESUMO

Objective The aim of this study was to obtain data on phrenic neuroconduction and electromyography of the diaphragm muscle in difficult-to-treat asthmatic patients and compare the results to those obtained in controls. Methods The study consisted of 20 difficult-to-treat asthmatic patients compared with 27 controls. Spirometry, maximal inspiratory and expiratory pressure, chest X-ray, phrenic neuroconduction and diaphragm electromyography data were obtained. Results The phrenic compound motor action potential area was reduced, compared with controls, and all the patients had normal diaphragm electromyography. Conclusion It is possible that a reduced phrenic compound motor action potential area, without electromyography abnormalities, could be related to diaphragm muscle fiber abnormalities due to overload activity.


Assuntos
Asma/fisiopatologia , Condução Nervosa/fisiologia , Nervo Frênico/fisiopatologia , Potenciais de Ação/fisiologia , Adulto , Fatores Etários , Idoso , Asma/diagnóstico por imagem , Estudos de Casos e Controles , Diafragma/fisiopatologia , Eletromiografia/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Nervo Frênico/diagnóstico por imagem , Doença Pulmonar Obstrutiva Crônica/fisiopatologia , Radiografia Torácica , Valores de Referência , Testes de Função Respiratória/métodos , Estatísticas não Paramétricas , Adulto Jovem
3.
Arq Neuropsiquiatr ; 75(12): 869-874, 2017 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-29236890

RESUMO

OBJECTIVE: The aim of the present study was to define normative data of phrenic nerve conduction parameters of a healthy population. METHODS: Phrenic nerve conduction studies were performed in 27 healthy volunteers. RESULTS: The normative limits for expiratory phrenic nerve compound muscle action potential were: amplitude (0.47 mv - 0.83 mv), latency (5.74 ms - 7.10 ms), area (6.20 ms/mv - 7.20 ms/mv) and duration (18.30 ms - 20.96 ms). Inspiratory normative limits were: amplitude (0.67 mv - 1.11 mv), latency (5.90 ms - 6.34 ms), area (5.62 ms/mv - 6.72 ms/mv) and duration (13.77 ms - 15.37 ms). CONCLUSION: The best point of phrenic nerve stimulus in the neck varies among individuals between the medial and lateral border of the clavicular head of the sternocleidomastoid muscle and stimulation of both sites, then choosing the best phrenic nerve response, seems to be the appropriate procedure.


Assuntos
Potenciais de Ação/fisiologia , Condução Nervosa/fisiologia , Nervo Frênico/fisiologia , Tempo de Reação/fisiologia , Adulto , Estimulação Elétrica , Eletromiografia , Feminino , Voluntários Saudáveis , Humanos , Masculino , Pessoa de Meia-Idade , Exame Neurológico , Adulto Jovem
4.
Arq. neuropsiquiatr ; 76(3): 177-182, Mar. 2018. tab, graf
Artigo em Inglês | LILACS | ID: biblio-888364

RESUMO

ABSTRACT Objective The aim of this study was to obtain data on phrenic neuroconduction and electromyography of the diaphragm muscle in difficult-to-treat asthmatic patients and compare the results to those obtained in controls. Methods The study consisted of 20 difficult-to-treat asthmatic patients compared with 27 controls. Spirometry, maximal inspiratory and expiratory pressure, chest X-ray, phrenic neuroconduction and diaphragm electromyography data were obtained. Results The phrenic compound motor action potential area was reduced, compared with controls, and all the patients had normal diaphragm electromyography. Conclusion It is possible that a reduced phrenic compound motor action potential area, without electromyography abnormalities, could be related to diaphragm muscle fiber abnormalities due to overload activity.


RESUMO Objetivo O objetivo do presente estudo foi obter dados da neurocondução do frênico e exame com agulha do diafragma em pacientes com asma de difícil controlee comparar com um grupo normal. Métodos O estudo consiste em realizar radiografia de tórax, espirometria, pressão máxima inspiratória e expiratória, neurocondução do nervo frênico e eletromiografia do músculo diafragma em 20 pacientes asmáticos de difícil controle e comparar com 27 controles. Resultados Encontramos redução da área do potencial de ação muscular composto do nervo frênico e a eletromiografia do musculo diafragma estava normal em todos os pacientes. Conclusão É possível que a redução da área do potencial de ação muscular composto do nervo frênico nos pacientes com asma de difícil controle associado a eletromiografia normal do músculo diafragma esteja relacionada as alterações da fibra muscular do mesmo devido à sobrecarga de atividade.


Assuntos
Humanos , Masculino , Feminino , Adulto , Pessoa de Meia-Idade , Idoso , Adulto Jovem , Nervo Frênico/fisiopatologia , Asma/fisiopatologia , Condução Nervosa/fisiologia , Nervo Frênico/diagnóstico por imagem , Valores de Referência , Testes de Função Respiratória/métodos , Asma/diagnóstico por imagem , Potenciais de Ação/fisiologia , Diafragma/fisiopatologia , Radiografia Torácica , Estudos de Casos e Controles , Fatores Etários , Estatísticas não Paramétricas , Doença Pulmonar Obstrutiva Crônica/fisiopatologia , Eletromiografia/métodos
5.
Arq. neuropsiquiatr ; 75(12): 869-874, Dec. 2017. tab, graf
Artigo em Inglês | LILACS | ID: biblio-888278

RESUMO

ABSTRACT Objective: The aim of the present study was to define normative data of phrenic nerve conduction parameters of a healthy population. Methods: Phrenic nerve conduction studies were performed in 27 healthy volunteers. Results: The normative limits for expiratory phrenic nerve compound muscle action potential were: amplitude (0.47 mv - 0.83 mv), latency (5.74 ms - 7.10 ms), area (6.20 ms/mv - 7.20 ms/mv) and duration (18.30 ms - 20.96 ms). Inspiratory normative limits were: amplitude (0.67 mv - 1.11 mv), latency (5.90 ms - 6.34 ms), area (5.62 ms/mv - 6.72 ms/mv) and duration (13.77 ms - 15.37 ms). Conclusion: The best point of phrenic nerve stimulus in the neck varies among individuals between the medial and lateral border of the clavicular head of the sternocleidomastoid muscle and stimulation of both sites, then choosing the best phrenic nerve response, seems to be the appropriate procedure.


RESUMO Objetivo: O objetivo do presente estudo foi definir os dados normativos de condução do nervo frênico de uma população saudável. Métodos: Foram realizados estudos de condução do nervo frênico em 27 voluntários saudáveis. Resultados: Os limites normais do potencial de ação muscular composto do nervo frênico durante a expiração foram: amplitude (0.47 mv - 0.83 mv), latência (5.74 ms - 7.10 ms), área (6.20 ms/mv - 7.20 ms/mv) e duração (18.30 ms - 20.96 ms). E durante a inspiração os limites normais foram: amplitude (0.67 mv - 1.11 mv), latência (5.90 ms - 6.34 ms), área (5.62 ms/mv - 6.72 ms/mv) e duração (13.77 ms - 15.37 ms). Conclusão: O melhor ponto de estímulo do nervo frênico no pescoço varia entre a borda medial e lateral da cabeça clavicular do músculo esternocleidomastóideo. Estimular ambos os locais e escolher a melhor resposta do nervo frênico parece ser o procedimento mais adequado.


Assuntos
Humanos , Masculino , Feminino , Adulto , Pessoa de Meia-Idade , Adulto Jovem , Nervo Frênico/fisiologia , Tempo de Reação/fisiologia , Potenciais de Ação/fisiologia , Condução Nervosa/fisiologia , Estimulação Elétrica , Eletromiografia , Voluntários Saudáveis , Exame Neurológico
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa