RESUMO

PURPOSE: Vegetation size is a prognostic predictor in infective endocarditis (IE) and guides surgical management. The aim of this study was to evaluate the accuracy of real-time 3-dimensional transesophageal echocardiography (RT3DTEE) compared to 2DTEE in the diagnosis and characterization of vegetation, as well as its potential clinical impact. METHODS: Two hundred and three consecutive patients with IE were recruited (2009-2016) and retrospectively analyzed. Vegetation diameters and area from 68 patients were measured by 2DTEE and RT3DTEE at admission. The association between size and systemic embolisms was evaluated with logistic regression models. Differences in the discriminative power for the best dimensions' cutoff points were assessed by comparing the area under the ROC curves (AUC). RESULTS: Vegetation size and area were larger by RT3DTEE (P < 0.001) than by 2DTEE, and RT3DTEE was especially relevant in the characterization of nonfiliform vegetation, Morphology was strongly associated with friability, being sessile vegetation less likely to embolize, compared to filiform and raceme-shaped ones (15.4% vs 46% vs 50%). Major diameter by RT3DTEE had better embolic predictive performance than 2DTEE (AUC 0.76 [0.57-0.89] vs 0.71 [0.53-0.86]; P = 0.611). The best cutoff points associated with embolic events during the infection were 17 mm for RT3DTEE and 15 mm for 2DTEE. Based exclusively on vegetation size, the proportion of patients meeting a surgical indication according to current guidelines is higher using RT3DTEE. CONCLUSIONS: RT3DTEE allows a better characterization of IE vegetation than 2DTEE, what may have a clinical impact on surgical management and also prognostic due to a more accurate prediction of embolic risk.


Assuntos
Ecocardiografia Tridimensional/métodos , Ecocardiografia Transesofagiana/métodos , Endocardite/diagnóstico por imagem , Idoso , Endocárdio/diagnóstico por imagem , Endocárdio/microbiologia , Feminino , Humanos , Masculino , Reprodutibilidade dos Testes , Estudos Retrospectivos , Índice de Gravidade de Doença
2.
Circ J ; 82(11): 2880-2886, 2018 10 25.
Artigo em Inglês | MEDLINE | ID: mdl-30135324

RESUMO

BACKGROUND: Prosthesis-patient mismatch (PPM) after transcatheter aortic valve replacement (TAVR) remains an important issue. The aim of this study was to assess the value of a new discongruence index, to predict PPM after TAVR.Methods and Results: A total of 185 patients with severe aortic stenosis who underwent TAVR with the Edwards Sapien prosthesis or CoreValve Revalving system were included (Edwards valve, n=119; Core Valve Revalving system, n=66). Discongruence index was calculated pre-procedurally as the ratio of selected transcatheter valve size (mm) to body surface area (cm2). PPM was defined as effective orifice area (EOA) ≤0.85 cm2/m2 on transthoracic echocardiography before hospital discharge. Mean age was 82±5 years and 72 patients (38.9%) were men. The overall incidence of post-TAVR PPM was 35.1% (n=65). Discongruence index correlated with post-TAVR indexed EOA (y=0.18+0.057x; P<0.001). On multivariate logistic regression analysis, discongruence index was the only independent predictor of post-TAVR PPM (OR, 0.15; 95% CI: 0.03-0.66; P=0.012), and the area under the receiver operating characteristic curve was 0.62 (95% CI: 0.54-0.70, P=0.003), with an optimal cut-off point of 15.02 (sensitivity, 86.2%; specificity, 72.5%; positive predictive value, 74.3%; negative predictive value, 83.4%). CONCLUSIONS: The new discongruence index may be useful tool to predict PPM after TAVR.


Assuntos
Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Ecocardiografia , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino
3.
Echocardiography ; 35(11): 1812-1817, 2018 11.
Artigo em Inglês | MEDLINE | ID: mdl-30079468

RESUMO

INTRODUCTION: Mitral regurgitation severity assessment is usually carried out using qualitative, semiquantitative, and quantitative parameters. The mitral valve navigation (MVN) tool allows to measure the mitral effective regurgitant orifice (MERO) from 3D echo datasets. Our aim was to validate the MVN as a new tool to quantify MERO. A secondary aim was to assess the intra- and interobserver variability. METHODS: This is a retrospective study in which consecutive subjects undergoing a transoesophageal echocardiogram for more than mild mitral regurgitation evaluation were included. MERO measurement obtained by means of 3D color Doppler was used as the gold standard method for comparison. In every patient, MERO was also obtained using the MVN tool. RESULTS: Fifty-nine consecutive patients were analyzed (47.5% female; mean age 50.8 years). Mitral regurgitation was moderate in 23 (39%) and severe in 36 (61%) patients. Forty patients (67.8%) had a primary and 19 (32.2%) a secondary mitral regurgitation. The intraclass correlation coefficient (ICC) between 3D color Doppler and MVN was excellent (ICC: 0.95; 95% CI: 0.82 to 0.98; P < 0.001) in the total group and for patients with primary and secondary mitral regurgitation. Intra- and interobserver agreements were also good. CONCLUSIONS: Mitral valve navigator shows an excellent accuracy for measuring MERO when the transoesophageal 3D color Doppler is used as the reference method, either primary or secondary mitral regurgitation. Intraobserver reproducibility and interobserver reproducibility are also excellent. These findings make this software a good alternative method to measure mitral regurgitation severity.


Assuntos
Ecocardiografia Tridimensional/instrumentação , Ecocardiografia Tridimensional/métodos , Ecocardiografia Transesofagiana/instrumentação , Ecocardiografia Transesofagiana/métodos , Insuficiência da Valva Mitral/diagnóstico por imagem , Estudos de Coortes , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valva Mitral/diagnóstico por imagem , Valva Mitral/fisiopatologia , Insuficiência da Valva Mitral/fisiopatologia , Variações Dependentes do Observador , Reprodutibilidade dos Testes , Estudos Retrospectivos , Sensibilidade e Especificidade , Índice de Gravidade de Doença
4.
Echocardiography ; 32(4): 644-53, 2015 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-25091933

RESUMO

BACKGROUND/OBJECTIVES: Atrial fibrillation (AF) is the most common cardiac arrhythmia and is associated with a significantly high risk of stroke and systemic embolism. The aim of our study was to assess the association between left atrium (LA) mechanics measured by 3D wall-motion tracking (3DWMT) technology and the most common thromboembolic risk scores (CHADS2, CHA2DS2-VASc). METHODS: A total of 101 consecutive patients with permanent AF referred were included. Conventional bidimensional (2D) LA parameters, and LA mechanics by means of 3DWMT were studied. Association between LA 2D and 3DWMT parameters and both risk scores was evaluated as well as its correlation with every component of the score individually. RESULTS: Mean age was 78 ± 10 years. Mean CHADS2 was 2.7 ± 1.3 and mean CHA2DS2-VASc was 4.4 ± 1.7. Values of 2D and 3DWTM LA parameters were: 2D area 26.4 ± 9.7 cm(2) , 2D volume index 49.4 ± 10.1 mL/m(2) , 3DWMT left atrial emptying fraction (LAEF) 15.9 ± 8.4%, longitudinal strain 9.1 ± 4.5% and area strain 14.9 ± 8.8%. Linear regression analysis showed statistically significant correlation between LA longitudinal strain and LAEF with CHADS2 and CHA2DS2-VASc scores. For each 10% variation in longitudinal strain, CHADS2 and CHA2DS2-VASc scores change in 0.7 and 0.8 points, respectively. CONCLUSIONS: Left atrial longitudinal strain and emptying fraction assessed by 3D WMT technology have correlation with both CHADS2 and CHA2DS2-VASc scores. Each 10% of variation in longitudinal strain represents a 0.7 and 0.8 points change in those risk scores. LA mechanics evaluation might provide additional value to risk scores and could be considered to be a predictor of stroke in patients with AF.


Assuntos
Fibrilação Atrial/epidemiologia , Ecocardiografia Tridimensional/estatística & dados numéricos , Átrios do Coração/diagnóstico por imagem , Átrios do Coração/fisiopatologia , Tromboembolia/diagnóstico por imagem , Tromboembolia/epidemiologia , Idoso , Fibrilação Atrial/diagnóstico por imagem , Causalidade , Comorbidade , Ecocardiografia Tridimensional/métodos , Feminino , Humanos , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Incidência , Masculino , Reprodutibilidade dos Testes , Medição de Risco , Sensibilidade e Especificidade , Espanha/epidemiologia
5.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-38844072

RESUMO

INTRODUCTION AND OBJECTIVES: There is limited evidence to identify the most accurate method for measuring the mitral valve area (MVA) after percutaneous edge-to-edge mitral repair. Our objective was to evaluate the optimal method in this context and its correlation with the mean transmitral gradient. METHODS: A registry of patients undergoing percutaneous mitral repair was conducted, analyzing different methods of measuring MVA and their correlation with the mean gradient. RESULTS: We analyzed data from 167 patients. The mean age was 76±10.3 years, 54% were men, and 46% were women. Etiology was degenerative in 45%, functional in 39%, and mixed in 16%. Postclip MVA measurements were 1.89±0.60 cm2 using pressure half-time (PHT), 2.87±0.83 cm2 using 3D planimetry, and the mean gradient was 3±1.19mmHg. MVA using 3D planimetry showed a stronger correlation with the mean gradient (r=0.46, P<.001) than MVA obtained by PHT (r=0.19, P=.048). Interobserver agreement was also higher with 3D planimetry than with PHT (intraclass correlation coefficient of 0.90 vs 0.81 and variation coefficient of 9.6 vs 19.7%, respectively). CONCLUSIONS: Our study demonstrates that the PHT method significantly underestimates MVA after clip implantation compared with direct measurement using transesophageal 3D planimetry. The latter method also correlates better with postimplantation gradients and has less interobserver variability. These results suggest that 3D planimetry is a more appropriate method for assessing postclip mitral stenosis.

6.
Echocardiography ; 30(6): 667-71, 2013 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-23336434

RESUMO

BACKGROUND: Current guidelines do not recommend routine assessment of right atrial volume due to the lack of standardized data. Three-dimensional wall-motion tracking (3D-WMT) is a new technology that allows us to calculate volumes without any geometric assumptions. The aim of this study was to define the indexed reference values for two-dimensional echocardiography (2D-echo) and 3D-WMT in adult healthy population and to assess the intermethod, intra- and interobserver agreement. METHODS: Prospective study. Nonselected healthy subjects were enrolled. Every patient underwent a 2D-echo and a 3D-WMT examination. 2D-echo right atrial volume was obtained by using the area-length method (A-L) from four- and two-chamber view. 3D-echo volumes were assessed by 3D-WMT. Values were indexed by the patient's body surface area. RESULTS: Sixty consecutive healthy subjects were enrolled. Mean age was 57 ± 12-years old and 27 patients (45%) were male. Average indexed right atrial volume obtained by 2D-echo and 3D-echo was 16.76 ± 8.15 mL/m(2) and 19.05 ± 6.87 mL/m(2) , respectively. Univariate linear regression analysis between 2D-echo and 3D-echo right atrial volumes shows a weak correlation between right atrial volume obtained with 2D-echo compared with 3D-WMT (r = 0.29, CI 95% 0.029-0.66, P = 0.033). The agreement analysis shows a similar result (intraclass correlation coefficient [ICC] = 0.28). The intra- and interobserver agreement analysis showed a better agreement when using 3D-WMT. CONCLUSIONS: This is the first study that reports the reference indexed right atrial volume values by means of 2D-echo and 3D-echo in healthy population. 3D-WMT is a feasible and reproducible method to determine right atrial volume.


Assuntos
Função Atrial/fisiologia , Ecocardiografia Tridimensional/estatística & dados numéricos , Ecocardiografia Tridimensional/normas , Átrios do Coração/diagnóstico por imagem , Tamanho do Órgão/fisiologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Valores de Referência , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Espanha/epidemiologia
7.
J Clin Med ; 12(24)2023 Dec 18.
Artigo em Inglês | MEDLINE | ID: mdl-38137816

RESUMO

This review article describes in depth the current usefulness of transesophageal echocardiography in patients who undergo transcatheter aortic valve replacement. Pre-intervention, 3D-transesophageal echocardiography allows us to accurately evaluate the aortic valve morphology and to measure the valve annulus, helping us to choose the appropriate size of the prosthesis, especially useful in cases where the computed tomography is not of adequate quality. Although it is not currently used routinely during the intervention, it remains essential in those cases of greater complexity, such as for patients with greater calcification and bicuspid valve, mechanical mitral prosthesis, and "valve in valve" procedures. Three-dimensional transesophageal echocardiography is the best technique to detect and quantify paravalvular regurgitation, a fundamental aspect to decide whether immediate valve postdilation is needed. It also allows to detect early any immediate complications such as cardiac tamponade, aortic hematoma or dissection, migration of the prosthesis, malfunction of the prosthetic leaflets, or the appearance of segmental contractility disorders due to compromise of the coronary arteries ostium. Transesophageal echocardiography is also very useful in follow-up, to check the proper functioning of the prosthesis and to rule out complications such as thrombosis of the leaflets, endocarditis, or prosthetic degeneration.

8.
Nat Commun ; 14(1): 4613, 2023 08 04.
Artigo em Inglês | MEDLINE | ID: mdl-37542075

RESUMO

Electromechanical characterization during atrial fibrillation (AF) remains a significant gap in the understanding of AF-related atrial myopathy. This study reports mechanistic insights into the electromechanical remodeling process associated with AF progression and further demonstrates its prognostic value in the clinic. In pigs, sequential electromechanical assessment during AF progression shows a progressive decrease in mechanical activity and early dissociation from its electrical counterpart. Atrial tissue samples from animals with AF reveal an abnormal increase in cardiomyocytes death and alterations in calcium handling proteins. High-throughput quantitative proteomics and immunoblotting analyses at different stages of AF progression identify downregulation of contractile proteins and progressive increase in atrial fibrosis. Moreover, advanced optical mapping techniques, applied to whole heart preparations during AF, demonstrate that AF-related remodeling decreases the frequency threshold for dissociation between transmembrane voltage signals and intracellular calcium transients compared to healthy controls. Single cell simulations of human atrial cardiomyocytes also confirm the experimental results. In patients, non-invasive assessment of the atrial electromechanical relationship further demonstrate that atrial electromechanical dissociation is an early prognostic indicator for acute and long-term rhythm control.


Assuntos
Fibrilação Atrial , Remodelamento Atrial , Doenças Musculares , Humanos , Animais , Suínos , Prognóstico , Cálcio/metabolismo , Átrios do Coração/metabolismo
10.
J Clin Med ; 11(9)2022 Apr 19.
Artigo em Inglês | MEDLINE | ID: mdl-35566402

RESUMO

Background: There is no consensus on the best intraprocedural parameter to evaluate residual mitral regurgitation (MR) after transcatheter edge-to-edge mitral repair (TEER). Thus, our aim was to evaluate the predictive value of different MR parameters from intraprocedural transesophageal echocardiogram (TEE) for grading in consecutive transthoracic echocardiogram (TTE) during the follow up. Methods: All the consecutive patients who underwent TEER with MitraClip between 2010 and 2020 in our center were considered. TEE-derived immediate postprocedural MR parameters were reassessed to blindly compare them with follow up MR grading in sequential TTE. Results: We finally included 88 patients (64.8% males; 76 ± 10 years-old). Significant MR was detected in 14.3% of the cases at 6 months, in similar proportion than at postprocedural at 1 month. Among all the intraprocedural TEE quantitative parameters only additive and maximum VC were associated with significant MR persistence. Moreover, on ROC analysis maximum VC demonstrated an excellent discriminatory power (AUC 0.96; p < 0.001) to identify MR ≥ III at 6 months. Thus, a cut-off point of 0.45 cm demonstrated 88% sensitivity and 89% specificity. Conclusion: Among intraprocedural TEE parameters to evaluate residual MR in TEER, maximum and additive VC were the most reliable to predict persistence of significant insufficiency.

11.
Eur J Echocardiogr ; 12(4): 335-7, 2011 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-21377977

RESUMO

Prosthesis deterioration rate, years after a previous surgical valve replacement, is rising. Usually, the standard management is reoperation, but for very high risk patients an alternative has arisen: the valve-in-valve approach. We present an 84-year-old Caucasian woman with a mitral bioprosthesis (Mosaic II, number 29) since 1994. Over the last few months the patient displayed worsening heart failure symptoms, until her current admission in NYHA III-IV functional class, because of a severely degenerated mitral prosthesis (severe regurgitation, severe pulmonary hypertension). The transapical access, conventionally used for transcatheter aortic valve implantation (Edwards SAPIEN THV 23) was chosen, guided by transoesophageal echocardiography (TOE) with a new three-dimensional (3D) probe. After the procedure, the mitral regurgitation completely disappeared, an appropriate valve opening was achieved (valve area >2 cm(2)) and the patient was discharged 6 days later, remaining well in the outpatient follow-up. Only a restricted number of patients have been submitted to mitral transcatheter valve-in-valve implantation and to the best of our knowledge this is the first accurate description of the 3D TOE part, focusing on the surgeon requirements.


Assuntos
Bioprótese/efeitos adversos , Ecocardiografia Tridimensional , Implante de Prótese de Valva Cardíaca/métodos , Próteses Valvulares Cardíacas/efeitos adversos , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/cirurgia , Ultrassonografia de Intervenção , Idoso de 80 Anos ou mais , Cateterismo Cardíaco , Feminino , Humanos , Insuficiência da Valva Mitral/etiologia , Estenose da Valva Mitral/diagnóstico por imagem , Estenose da Valva Mitral/cirurgia
12.
Eur J Echocardiogr ; 12(10): 790-7, 2011 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-21865229

RESUMO

AIMS: Data regarding the effects of TAVI on LV after are scarce and conflicting results have been reported immediately after aortic valvuloplasty. This study aimed to determine the acute haemodynamic effects of transcatheter aortic valve implantation (TAVI) in left ventricle (LV) diastolic performance, immediately after aortic valvuloplasty and prosthesis deployment. METHODS AND RESULTS: Sixty-one patients with severe aortic valve stenosis, and preserved LV systolic function submitted to successful TAVI, were included. All procedures were guided through transoesophageal echocardiography, and parameters of diastolic function were evaluated before and minutes after TAVI. The mean age was 83.5±6 years and mean log EuroSCORE was 18.2±9.4. Before the procedure, all patients presented LV diastolic dysfunction. Immediately after TAVI, fewer patients presented a restrictive pattern [27 (44.3%), before the procedure, vs. 20 (34.4%), after TAVI (P=0.047)], and an increase in E wave deceleration time (211.2±75.5 vs. 252.7±102.3 cm/s, P=0.001), in E wave velocity (109.5±41.2 vs. 120.3±43.6 cm/s, P=0.025), and in isovolumetric relaxation time (83±36.5 vs. 97.1±36.0 ms, P=0.013) was observed. On multivariate analysis of covariance (ANCOVA), adjusting to LV systolic function, heart rate, blood pressure, and haematocrit values, the results remained significant. Patients referred to percutaneous approach had invasive haemodynamic data collected, showing a decrease in LV end-diastolic pressure after valve implantation [18.8±5.7 vs. 14.7±4.7, mean difference -4.1 (95% CI: -5.9; -2.9)]. Patients with a restrictive pattern immediately after TAVI presented a smaller decrease in LV end diastolic pressure (-3.3±4.7) than those with diastolic dysfunction grade I or II (-9.5±4.7; P=0.017). CONCLUSION: This is the first study describing LV diastolic performance during TAVI. Our results show improvement in diastolic function parameters in patients with preserved LV systolic function, immediately after successful TAVI.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Implante de Prótese de Valva Cardíaca , Disfunção Ventricular Esquerda/cirurgia , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/fisiopatologia , Cateterismo Cardíaco , Diástole , Ecocardiografia Transesofagiana , Humanos , Disfunção Ventricular Esquerda/diagnóstico por imagem , Disfunção Ventricular Esquerda/fisiopatologia
13.
Expert Rev Cardiovasc Ther ; 19(8): 711-723, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-34275408

RESUMO

INTRODUCTION: Significant mitral regurgitation (MR) frequently coexists in patients with severe symptomatic aortic stenosis undergoing transcatheter aortic valve replacement (TAVR). These patients have worse clinical outcomes than those with non-significant MR, especially if MR persists after treatment of the aortic stenosis. The optimal treatment approach for this challenging high-risk population is not well defined. AREAS COVERED: This review aims to present the current literature on concomitant significant MR in the TAVR population, and to provide a comprehensive algorithmic approach for clinical decision-making in this challenging cohort of patients. EXPERT OPINION: Concomitant mitral and aortic valve disease is a complex clinical entity. An exhaustive and comprehensive assessment of patient's clinical characteristics and mitral valve anatomy and function is required in order to assess the surgical risk, predict the MR response after AVR and evaluate the feasibility of percutaneous MV treatment if necessary. Further developments in transcatheter techniques will expand the indications for double valve treatment in operable and inoperable patients with concomitant significant MR and aortic stenosis.


Assuntos
Estenose da Valva Aórtica , Insuficiência da Valva Mitral , Substituição da Valva Aórtica Transcateter , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/complicações , Estenose da Valva Aórtica/cirurgia , Humanos , Insuficiência da Valva Mitral/cirurgia , Índice de Gravidade de Doença , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
14.
Rev Esp Cardiol (Engl Ed) ; 74(2): 159-166, 2021 Feb.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-32198007

RESUMO

INTRODUCTION AND OBJECTIVES: Myocardial strain analysis could provide additional information to left ventricular ejection fraction (LVEF) in nonischemic dilated cardiomyopathy (NIDC). Our aim was to analyze the feasibility of left ventricular strain evaluation using cardiac magnetic resonance feature tracking (FT) in NIDC, and to determine its clinical and prognostic impact. METHODS: We retrospectively included consecutive patients with NIDC who underwent cardiac magnetic resonance. Left ventricular global longitudinal, circumferential and radial strain were obtained from standard cine sequences using FT analysis software. We evaluated their association with a composite endpoint (heart failure, implantable cardioverter-defibrillator in secondary prevention, or death). RESULTS: FT analysis could be performed in all of the 98 patients (mean age 68±13 years, 72% men). Intra- and interobserver concordance was good for global longitudinal and circumferential strain but was worse for radial strain. Global circumferential strain was independently associated (OR, 1.16; P=.045) with LVEF normalization during follow-up and was the only morphological parameter independently associated with the composite endpoint (OR, 1.15; P=.038). A cutoff value <-8.2% was able to predict the incidence of this event during follow-up (log-rank 4.6; P=.032). CONCLUSIONS: Left ventricular strain analysis with FT is feasible and reproducible in NIDC. Global circumferential strain was able to predict LVEF recovery and the appearance of major cardiovascular events during follow-up.


Assuntos
Cardiomiopatia Dilatada/diagnóstico por imagem , Imagem Cinética por Ressonância Magnética/métodos , Volume Sistólico/fisiologia , Função Ventricular Esquerda/fisiologia , Idoso , Idoso de 80 Anos ou mais , Cardiomiopatia Dilatada/complicações , Cardiomiopatia Dilatada/diagnóstico , Estudos de Viabilidade , Feminino , Humanos , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Prognóstico , Reprodutibilidade dos Testes , Estudos Retrospectivos
15.
Echocardiography ; 27(10): 1238-46, 2010 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-20584068

RESUMO

BACKGROUND: High blood pressure increases left ventricular (LV) after-load. Furthermore, LV response to that high blood pressure varies among different subjects. Nevertheless, myocardial deformation behavior in these different adaptative responses has not been analyzed until now. METHODS: Prospective study in which 66 consecutive hypertensive patients were enrolled in between May and August 2009. Every patient underwent a standard echocardiographic study and a three-dimensional-wall motion tracking (3D-WMT) study. The patients were classified according to parameters derived from echocardiography in four different groups: normal geometry, concentric remodelling, concentric hypertrophy, and eccentric hypertrophy. RESULTS: Mean age was 68 years (57-74.25; 51.5% male). Comparing the four groups, significant differences were found for the five 3D-WMT-derived parameters. When patients were compared with hypertensive patients with normal geometry, our finding show that: (a) LV average torsion is the only impaired parameter that is found in the LV concentric remodelling group (P < 0.05 vs. group 1); (b) there is a trend for an increase (P = 0.055) in LV average radial strain in the group with concentric hypertrophy and this increase is accompanied by a significant decrease in the remaining studied parameters (P < 0.05); and (c) in the LV eccentric hypertrophy group, there is a significant impairment in all the studied parameters (P < 0.05). CONCLUSIONS: LV adaptative response to hypertension is accompanied by a modification or even impairment, in LV myocardial deformation evaluated by 3D-WMT. This assessment might be useful to detect early and subtle deformation impairments in hypertensive patients and it could help optimize their clinical management.


Assuntos
Ecocardiografia Tridimensional/métodos , Técnicas de Imagem por Elasticidade/métodos , Ventrículos do Coração/diagnóstico por imagem , Ventrículos do Coração/fisiopatologia , Hipertensão/diagnóstico por imagem , Hipertensão/fisiopatologia , Adaptação Fisiológica , Idoso , Módulo de Elasticidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade
16.
Tex Heart Inst J ; 47(2): 165-167, 2020 04 01.
Artigo em Inglês | MEDLINE | ID: mdl-32603454

RESUMO

Anomalous origin of the left coronary artery from the opposite sinus of Valsalva with an intramural aortic course is a rare congenital anomaly with a poor prognosis. We report the case of a 14-year-old soccer player who briefly lost consciousness while sprinting. He had exertional chest pain, syncope, ischemic changes on his electrocardiogram, and elevated cardiac troponin levels. Computed tomographic angiograms showed an anomalous origin of the left coronary artery from the right sinus of Valsalva and a course through the aortic wall toward the left coronary sinus. A surgically created neo-ostium in the left coronary sinus relieved the patient's ischemia, and he resumed playing soccer after cardiac rehabilitation.


Assuntos
Atletas , Vasos Coronários/diagnóstico por imagem , Eletrocardiografia , Seio Aórtico/anormalidades , Adolescente , Procedimentos Cirúrgicos Cardíacos/métodos , Angiografia Coronária , Anomalias dos Vasos Coronários , Vasos Coronários/cirurgia , Humanos , Masculino , Seio Aórtico/diagnóstico por imagem , Seio Aórtico/cirurgia , Tomografia Computadorizada por Raios X
19.
Rev Esp Cardiol (Engl Ed) ; 72(9): 732-739, 2019 Sep.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-30042008

RESUMO

INTRODUCTION AND OBJECTIVES: Late functional tricuspid regurgitation after rheumatic left-sided valve surgery is an important predictor of poor prognosis. This study investigated the usefulness and accuracy of 3-dimensional transthoracic echocardiography tricuspid area compared with conventional 2-dimensional diameter (2DD) for assessing significant tricuspid annulus dilatation, providing cutoff values that could be used in clinical practice to improve patient selection for surgery. METHODS: We prospectively included 109 patients with rheumatic heart disease in the absence of previous valve replacement. Tricuspid regurgitation was divided into 3 groups: mild, moderate, and severe. Optimal 3-dimensional area (3DA) and 2DD cutoff points for identification of significant tricuspid annulus dilatation were obtained and compared with current guideline thresholds. Predictive factors for 3DA dilatation were also assessed. RESULTS: Optimal cutoff points for both absolute and adjusted to body surface area (BSA) tricuspid annulus dilatation were identified (3DA: 10.4 cm2, 6.5 cm2/m2; 2DD: 35 mm, 21 mm/m2); 3DA/BSA had the best diagnostic performance (AUC=0.83). Three-dimensional transthoracic echocardiography tricuspid area helped to reclassify surgical indication in 14% of patients with mild tricuspid regurgitation (95%CI, 1%-15%; P=.03) and 37% with moderate tricuspid regurgitation (95%CI, 22%-37%; P<.0001), whereas 3DA/BSA changed surgery criteria in cases of mild tricuspid regurgitation (17%; 95%CI, 3%-17%; P=.01) compared with 2DD/BSA. On multivariable analysis, right and left atrial volumes and basal right ventricle diameter were independently correlated with 3DA. CONCLUSIONS: The current 40 mm threshold underestimates tricuspid annulus dilatation. Although 21 mm/m2 seems to be a reasonable criterion, the combination with 3DA assessment improves patient selection for surgery.


Assuntos
Anuloplastia da Valva Cardíaca/métodos , Ecocardiografia Tridimensional/métodos , Seleção de Pacientes , Insuficiência da Valva Tricúspide/cirurgia , Valva Tricúspide/diagnóstico por imagem , Idoso , Feminino , Humanos , Masculino , Reprodutibilidade dos Testes , Estudos Retrospectivos , Valva Tricúspide/cirurgia , Insuficiência da Valva Tricúspide/diagnóstico
20.
Eur J Echocardiogr ; 9(1): 101-2, 2008 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-17588502

RESUMO

We present the case of a rare echocardiographic image of a giant cavitated myxoma and the pathologic findings of the cystic mass. The new echocardiographic equipment not only has improved the sensitivity for diagnosis of different pathologies but also has redefined its visual and morphologic characteristics. Although most myxomas are solid masses and some cystic myxomas have been reported, the presence of multiple cavities on echocardiographic exam has exceptionally been described. While cystic changes have been described at autopsy in 14% of cardiac myxomas, its identification with echocardiography is rare. Nowadays, the new echocardiographic equipment has improved the quality and the accuracy to detect and describe intracardiac masses, showing myxomas with cystic cavities in vivo that in the past was a pathologic finding.


Assuntos
Cistos/diagnóstico por imagem , Ecocardiografia Transesofagiana , Neoplasias Cardíacas/diagnóstico por imagem , Mixoma/diagnóstico por imagem , Feminino , Átrios do Coração , Humanos , Pessoa de Meia-Idade
SELEÇÃO DE REFERÊNCIAS