Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 75
Filtrar
1.
Artigo em Inglês | MEDLINE | ID: mdl-38924232

RESUMO

INTRODUCTION: Identifying the origin of nonpulmonary vein atrial fibrillation (AF) triggers (NPVTs) after pulmonary vein isolation (PVI) can be challenging. We aimed to determine if noninvasive electrocardiographic imaging (ECGi) could localize pacing from common NPVT sites. ECGi combines measured body surface potentials with heart-torso geometry acquired from computed tomography (CT) to generate an activation map. METHODS: In 12 patients with AF undergoing first time ablation, the ECGi vest was fitted for preprocedural CT scan and worn during the procedure. After PVI, we performed steady-state pacing from 15 typical anatomic NPVT sites at a cycle length of 700-800 ms. We co-registered the invasive anatomic map with the CT-based ECGi epicardial activation map to compare ECGi predicted to true pacing origin. RESULTS: In the study cohort (67% male, 58% persistent AF, and 67% with left atrial dilation), 148 (82%) pacing sites had both capture and adequate anatomy acquired from the three-dimensional mapping system to co-register with ECGi activation map. Median distance between true pacing sites and point of earliest epicardial activation derived from the ECGi maps for all sites was 17 mm (interquartile range, 10-22 mm). Assuming paced sites treated as regions with a radius of 2.5 cm, the earliest activation site on ECGi map falls within the region with 94% accuracy. CONCLUSION: ECGi can approximate the origin of paced beats from common NPVT sites to within a median distance of 17 mm. A rapidly identified region may then be the focus of more detailed catheter-based mapping techniques to facilitate successful localization and ablation of NPVTs.

2.
Europace ; 26(7)2024 Jul 02.
Artigo em Inglês | MEDLINE | ID: mdl-38954426

RESUMO

AIMS: Prior case series showed promising results for cardioneuroablation in patients with vagally induced atrioventricular blocks (VAVBs). We aimed to examine the acute procedural characteristics and intermediate-term outcomes of electroanatomical-guided cardioneuroablation (EACNA) in patients with VAVB. METHODS AND RESULTS: This international multicentre retrospective registry included data collected from 20 centres. Patients presenting with symptomatic paroxysmal or persistent VAVB were included in the study. All patients underwent EACNA. Procedural success was defined by the acute reversal of atrioventricular blocks (AVBs) and complete abolition of atropine response. The primary outcome was occurrence of syncope and daytime second- or advanced-degree AVB on serial prolonged electrocardiogram monitoring during follow-up. A total of 130 patients underwent EACNA. Acute procedural success was achieved in 96.2% of the cases. During a median follow-up of 300 days (150, 496), the primary outcome occurred in 17/125 (14%) cases with acute procedural success (recurrence of AVB in 9 and new syncope in 8 cases). Operator experience and use of extracardiac vagal stimulation were similar for patients with and without primary outcomes. A history of atrial fibrillation, hypertension, and coronary artery disease was associated with a higher primary outcome occurrence. Only four patients with primary outcome required pacemaker placement during follow-up. CONCLUSION: This is the largest multicentre study demonstrating the feasibility of EACNA with encouraging intermediate-term outcomes in selected patients with VAVB. Studies investigating the effect on burden of daytime symptoms caused by the AVB are required to confirm these findings.


Assuntos
Bloqueio Atrioventricular , Sistema de Registros , Humanos , Masculino , Feminino , Estudos Retrospectivos , Idoso , Pessoa de Meia-Idade , Resultado do Tratamento , Bloqueio Atrioventricular/fisiopatologia , Bloqueio Atrioventricular/terapia , Bloqueio Atrioventricular/cirurgia , Ablação por Cateter/métodos , Fatores de Tempo , Estimulação do Nervo Vago/métodos , Técnicas Eletrofisiológicas Cardíacas , Síncope/etiologia , Recidiva , Nó Atrioventricular/cirurgia , Nó Atrioventricular/fisiopatologia
3.
Circulation ; 144(20): 1590-1597, 2021 11 16.
Artigo em Inglês | MEDLINE | ID: mdl-34780252

RESUMO

BACKGROUND: Prescription opioids are a major contributor to the ongoing epidemic of persistent opioid use (POU). The incidence of POU among opioid-naïve patients after cardiac implantable electronic device (CIED) procedures is unknown. METHODS: This retrospective cohort study used data from a national administrative claims database from 2004 to 2018 of patients undergoing CIED procedures. Adult patients were included if they were opioid-naïve during the 180-day period before the procedure and did not undergo another procedure with anesthesia in the next 180 days. POU was defined by filling an additional opioid prescription >30 days after the CIED procedure. RESULTS: Of the 143 400 patients who met the inclusion criteria, 15 316 (11%) filled an opioid prescription within 14 days of surgery. Among these patients, POU occurred in 1901 (12.4%) patients 30 to 180 days after surgery. The likelihood of developing POU was increased for patients who had a history of drug abuse (odds ratio, 1.52; P=0.005), preoperative muscle relaxant (odds ratio, 1.52; P<0.001) or benzodiazepine (odds ratio, 1.23; P=0.001) use, or opioid use in the previous 5 years (OR, 1.76; P<0.0001). POU did not differ after subcutaneous implantable cardioverter defibrillator or other CIED procedures (11.1 versus 12.4%; P=0.5). In a sensitivity analysis excluding high-risk patients who were discharged to a facility or who had a history of drug abuse or previous opioid, benzodiazepine, or muscle relaxant use, 8.9% of the remaining cohort had POU. Patients prescribed >135 mg of oral morphine equivalents had a significantly increased risk of POU. CONCLUSIONS: POU is common after CIED procedures, and 12% of patients continued to use opioids >30 days after surgery. Higher initially prescribed oral morphine equivalent doses were associated with developing POU.


Assuntos
Analgésicos Opioides/uso terapêutico , Desfibriladores Implantáveis , Cuidados Pós-Operatórios , Analgésicos Opioides/administração & dosagem , Analgésicos Opioides/efeitos adversos , Tomada de Decisão Clínica , Bases de Dados Factuais , Gerenciamento Clínico , Prescrições de Medicamentos/normas , Prescrições de Medicamentos/estatística & dados numéricos , Duração da Terapia , Pesquisas sobre Atenção à Saúde , Humanos , Vigilância em Saúde Pública
4.
Europace ; 23(4): 520-528, 2021 04 06.
Artigo em Inglês | MEDLINE | ID: mdl-33555014

RESUMO

Catheter ablation is increasingly utilized to treat patients with atrial fibrillation (AF). Despite progress in technology and procedural strategy, there remain significant limitations with suboptimal outcomes. The role of imaging has continued to evolve, and multimodality imaging now presents an important opportunity to make substantial progress in the safety and efficacy of ablation. In this review, we discuss the history of imaging in the ablation of AF with a specific focus on the ability of cardiac computed tomography and magnetic resonance imaging to characterize anatomy, arrhythmogenic substrate, and guide ablation strategy. We will review the progress that has been made and highlight many of the limitations as well as future directions for the field.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/cirurgia , Coração , Humanos , Imagem Multimodal , Tomografia Computadorizada por Raios X , Resultado do Tratamento
5.
J Cardiovasc Electrophysiol ; 31(11): 2883-2888, 2020 11.
Artigo em Inglês | MEDLINE | ID: mdl-32757450

RESUMO

INTRODUCTION: Functional tricuspid regurgitation (TR) remains a challenging clinical problem with poor outcomes and few effective treatments. Atrial fibrillation (AF) has been associated with functional TR. We sought to determine whether restoring sinus rhythm through catheter ablation of AF can decrease the degree of TR. METHODS AND RESULTS: A retrospective cohort study of patients undergoing AF ablation between 2011 and 2017 at a single center was conducted. We included patients with at least moderate TR on echocardiogram within the year preceding ablation, who underwent repeat echocardiogram within the year following ablation. Formal quantitative analysis was performed by an experienced research echocardiographer, blinded to arrhythmia outcomes. Arrhythmia-free survival was correlated to the extent of improvement in TR. Thirty-six patients met the inclusion criteria. A baseline echocardiogram was performed 37 ± 68 days before ablation and follow-up echocardiogram 139 ± 112 days following ablation. Patients were 63.7 ± 11.1 years old with a mean CHA2 DS2 -VASc score of 2.7 ± 1.7. The degree of TR improved by at least one grade in 23 patients (64%). TR area decreased from 11.6 ± 3.4 to 7.0 ± 3.5 cm2 (p < .001) following ablation. Freedom from AF postablation was associated with a greater likelihood of improvement in TR by at least one grade (100% vs. 41%, p = .02). CONCLUSIONS: In patients with AF and at least moderate TR, catheter ablation is associated with substantial improvement in TR severity.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Insuficiência da Valva Tricúspide , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Criança , Humanos , Recidiva , Estudos Retrospectivos , Resultado do Tratamento , Insuficiência da Valva Tricúspide/diagnóstico por imagem , Insuficiência da Valva Tricúspide/cirurgia
6.
J Electrocardiol ; 56: 29-33, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31247443

RESUMO

BACKGROUND: The mechanism of ST elevation on baseline electrocardiograms (ECG) unknown but it may be associated with abnormal myocardial substrate. This paper evaluates whether clinically unrecognized myocardial scar on cardiac magnetic resonance imaging (CMR) is associated with ST elevation at baseline. METHODS: The Multi-Ethnic Study of Atherosclerosis (MESA) study is a population-based cohort in the United States. Participants were aged 45 through 84 years and free of clinical cardiovascular disease at enrollment in 2000-2002. Our cohort included 1365 participants who underwent both ECG and contrast enhanced CMR in the 5th examination (2010-2012). Multivariable logistic regression examined the association of ST elevation and CMR defined regional myocardial scar after adjusting for cardiovascular risk factors. RESULTS: Of 1365 participants (58 ±9 years, 52% men), 105 (8%) had scar on CMR. Of these, the scar in 40 participants followed an ischemic pattern and in the other 65 participants followed a non-ischemic pattern. ST elevation at the 5th examination was present in 435 participants: 40 (0.9%) had ST elevations in inferior and 427 (98%) in lateral leads. 2/40 (5%) and 22/427 (5%) participants with inferior and lateral ST elevations, respectively, had evidence of scar. 15 (1.0%) had myocardial scar noted in the basal anterior region. In the fully adjusted models, ST elevation was associated with scar in basal anterior region (OR 18.2, p = 0.031). CONCLUSIONS: In a community population, ST elevation at baseline in the inferior or lateral leads was associated with myocardial scar in the basal inferior and anterior segments. The previously described association between ST elevation and increased mortality may be mediated by myocardial scar.


Assuntos
Aterosclerose , Infarto do Miocárdio com Supradesnível do Segmento ST , Cicatriz/patologia , Eletrocardiografia , Feminino , Humanos , Masculino , Miocárdio/patologia
8.
Pediatr Blood Cancer ; 64(11)2017 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-28453898

RESUMO

BACKGROUND: Anthracycline use is limited by cardiotoxicity, including arrhythmias and left ventricular (LV) dysfunction. We aim to characterize the association between electrophysiological changes and LV dysfunction. METHODS: A retrospective chart review was conducted, including all 147 pediatric cancer survivors at our institution over 18 years of age and treated with an anthracycline. One hundred thirty-four patients who had at least one electrocardiogram (ECG) and echocardiogram were analyzed. The association between dysfunction and baseline characteristics, treatment history, and electrocardigraphic parameters were analyzed using multivariable logistic regression. Additionally, a longitudinal generalized estimating equation (GEE) model was used to examine the temporal association between repeated measure corrected QT (QTc) intervals and subsequent LV function. RESULTS: In our population, 24% of patients had LV dysfunction. The initial posttreatment QTc interval was longer in patients with LV dysfunction (438 ± 35 vs. 420 ± 20 msec, P = 0.002). In logistic regression analysis, QTc interval (P < 0.001) and cumulative radiation dose (P = 0.027) were associated with LV dysfunction. On ECGs performed prior to evidence of LV dysfunction, the QTc was longer than on ECGs preceding a normal echocardiogram (451 ± 32 msec vs. 423 ± 25 msec, P < 0.001). Mean time from QTc ≥ 450 msec to evidence of LV dysfunction was 1.8 ± 2.9 years. In the longitudinal GEE model, QTc prolongation was associated with subsequent decreased fractional shortening. CONCLUSIONS: Among adult survivors of pediatric cancer treated with anthracyclines, prolongation of the QTc interval was associated with subsequent LV dysfunction.


Assuntos
Antraciclinas/efeitos adversos , Neoplasias/complicações , Disfunção Ventricular Esquerda/induzido quimicamente , Adulto , Criança , Eletrocardiografia , Fenômenos Eletrofisiológicos , Feminino , Seguimentos , Humanos , Masculino , Neoplasias/tratamento farmacológico , Prognóstico , Estudos Retrospectivos , Taxa de Sobrevida , Sobreviventes
10.
Oncology ; 91(2): 61-8, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27256307

RESUMO

IMPORTANCE: Cardiotoxicity is an important limiting factor in the use of antineoplastic agents. The risk of arrhythmia and the electrophysiological effects of these agents are poorly characterized though increasing evidence suggests a high prevalence of complications. OBSERVATIONS: Patients with substantial cardiovascular risk factors are often excluded from clinical trials, while the aging population of patients actually receiving therapies may have an underlying arrhythmogenic substrate due to comorbidities. Risk stratification of patients before the selection of a therapeutic regimen is essential. Given the regular use of combination therapies, the potential for arrhythmia of each agent must be fully understood. Despite limited data and understanding in clinical practice, decisions on whether to initiate specific therapies in high-risk patients and how to manage the associated complications are made regularly. CONCLUSIONS AND RELEVANCE: This review describes the observed arrhythmias and proposed mechanisms for several major classes of antineoplastic agents. It also provides recommendations for risk stratification, monitoring, prophylaxis, and therapy, emphasizing the need for a collaborative relationship between oncologists and cardiologists and areas for future research.


Assuntos
Antineoplásicos/efeitos adversos , Arritmias Cardíacas/induzido quimicamente , Arritmias Cardíacas/fisiopatologia , Cardiotoxicidade/fisiopatologia , Antraciclinas/efeitos adversos , Antimetabólitos Antineoplásicos/efeitos adversos , Antineoplásicos Alquilantes/efeitos adversos , Trióxido de Arsênio , Arsenicais/efeitos adversos , Humanos , Óxidos/efeitos adversos , Inibidores de Proteínas Quinases/efeitos adversos , Medição de Risco , Taxoides/efeitos adversos
12.
Curr Oncol Rep ; 16(8): 396, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-24992733

RESUMO

As antineoplastic treatment options expand at an increasing rate, both traditional and novel agents continue to be limited by their cardiotoxic effects. While functional decline becomes clinically apparent at late states of toxicity, little is known about early stages during which treatment or prevention may still be an option. Several imaging modalities,including echocardiography, multiple gated acquisition, and cardiac magnetic resonance imaging have the ability to identify cardiac effects before they produce clinical symptoms.Here we discuss the current and future role of cardiac imaging in the assessment of cardiotoxicity of antineoplastic agents. effects on cardiac tissue, resulting in myocardial cellular damage,and ultimately lead to a wide range of effects including electrophysiological abnormalities, symptomatic heart failure(HF), and even death. This represents a limiting factor in the therapy of several otherwise treatable neoplasms [2].The cardiotoxicity of antineoplastic agents raises several important questions regarding the actual prevalence of cardiac toxicity, the ability to effectively treat or prevent such effects with pharmaceutical interventions, and the availability of a means for early diagnosis. Here, we focus on the latter, specifically examining current and potential future imaging strategies to detect the cardiac effects of chemotherapeutic agents.


Assuntos
Antineoplásicos/efeitos adversos , Técnicas de Imagem Cardíaca , Cardiopatias/induzido quimicamente , Cardiotoxicidade/diagnóstico , Cardiopatias/diagnóstico , Humanos , Neoplasias/tratamento farmacológico
13.
JACC Clin Electrophysiol ; 10(6): 1206-1222, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38639702

RESUMO

Premature ventricular complexes (PVCs) are common arrhythmias in clinical practice. Although benign and asymptomatic in most cases, PVCs may result in disabling symptoms, left ventricular systolic dysfunction, or PVC-induced ventricular fibrillation. Catheter ablation has emerged as a first-line therapy in such cases, with high rates of efficacy and low risk of complications. Significant progress in mapping and ablation technology has been made in the past 2 decades, along with the development of a growing body of knowledge and accumulated experience regarding PVC sites of origin, anatomical relationships, electrocardiographic characterization, and mapping/ablation strategies. This paper provides an overview of the main indications for catheter ablation of PVCs, electrocardiographic features, PVC mapping techniques, and contemporary ablation approaches. The authors also review the most common sites of PVC origin and the main considerations and challenges with ablation in each location.


Assuntos
Ablação por Cateter , Eletrocardiografia , Complexos Ventriculares Prematuros , Complexos Ventriculares Prematuros/cirurgia , Complexos Ventriculares Prematuros/fisiopatologia , Humanos , Ablação por Cateter/métodos , Técnicas Eletrofisiológicas Cardíacas
14.
JACC Clin Electrophysiol ; 10(7 Pt 1): 1489-1507, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38661601

RESUMO

Electrophysiologic testing with programmed ventricular stimulation (PVS) has been utilized to induce ventricular tachycardia (VT), thereby improving risk stratification for patients with ischemic and nonischemic cardiomyopathies and determining the effectiveness of antiarrhythmic therapies, especially catheter ablation. A variety of procedural aspects can be modified during PVS in order to alter the sensitivity and specificity of the test including the addition of multiple baseline pacing cycle lengths, extrastimuli, and pacing locations. The definition of a positive result is also critically important, which has varied from exclusively sustained monomorphic VT (>30 seconds) to any ventricular arrhythmia regardless of morphology. In this review, we discuss the history of PVS and evaluate its role in sudden cardiac death risk stratification in a variety of patient populations. We propose an approach to future investigations that will capitalize on the unique ability to vary the sensitivity and specificity of this test. We then discuss the application of PVS during and following catheter ablation. The strategies that have been utilized to improve the efficacy of intraprocedural PVS are highlighted during a discussion of the limitations of this probabilistic strategy. The role of noninvasive programmed stimulation is also reviewed in predicting recurrent VT and informing management decisions including repeat ablations, modifications in antiarrhythmic drugs, and implantable cardioverter-defibrillator programming. Based on the available evidence and guidelines, we propose an approach to future investigations that will allow clinicians to optimize the use of PVS for risk stratification and assessment of therapeutic efficacy.


Assuntos
Ablação por Cateter , Taquicardia Ventricular , Humanos , Taquicardia Ventricular/terapia , Taquicardia Ventricular/fisiopatologia , Medição de Risco , Ablação por Cateter/métodos , Morte Súbita Cardíaca/prevenção & controle , Técnicas Eletrofisiológicas Cardíacas , Antiarrítmicos/uso terapêutico , Ventrículos do Coração/fisiopatologia
15.
Artigo em Inglês | MEDLINE | ID: mdl-39365212

RESUMO

BACKGROUND: Atrial conduction velocity (CV) is influenced by autonomic tone and contributes to the pathophysiology of re-entrant arrhythmias and atrial fibrillation. Cardiac sympathetic nerve activation has been reported via electrical stimulation within the vertebral vein (VV). OBJECTIVES: This study sought to characterize changes in right atrial (RA) CV associated with sympathetic stimulation from pharmacologic (isoproterenol) or direct electrical (VV stimulation) approaches. METHODS: Subjects undergoing catheter ablation for atrial fibrillation had baseline RA electroanatomic maps performed in sinus rhythm (SR). RA mapping was repeated during right VV stimulation (20 Hz; up to 20 mA) and again with both RA pacing and during isoproterenol infusion, each titrated to the heart rate achieved with VV stimulation. RESULTS: A total of 100 RA maps were analyzed from 25 subjects (mean age: 58 ± 14 years; 56% male), and CV was calculated from 51,534 electroanatomic map points. VV stimulation increased heart rate from baseline in all subjects (22.5 ± 5.5 beats/min). The average CV increased with VV stimulation (82.0 ± 34.5 cm/s) or isoproterenol (83.7 ± 35.0 cm/s) when compared to SR (70.8 ± 32.5 cm/s; P < 0.001). Heterogeneity of CV decreased with VV stimulation or isoproterenol when compared to SR (coefficient of variation: 0.33 ± 0.21 vs 0.35 ± 0.23 vs 0.57 ± 0.29; P < 0.001). There was no difference in CV or CV heterogeneity between SR and RA pacing, suggesting that these changes were independent of heart rate. CONCLUSIONS: Global RA CV is enhanced, and heterogeneity of CV is reduced, with either pharmacologic or direct electrical sympathetic stimulation via the right VV.

16.
Artigo em Inglês | MEDLINE | ID: mdl-39066979

RESUMO

BACKGROUND: Cardioneuroablation targeting the autonomic nerves within ganglionated plexus (GP) has been used to treat atrial fibrillation (AF). Incidental cardioneuroablation may be an important mechanism by which pulmonary vein isolation (PVI) is effective. Automated fractionation mapping software can identify regions of fractionation correlating with GP locations. OBJECTIVE: To examine the overlap between standard PVI ablation lesions and fractionated electrograms suggestive of GP. METHODS: We retrospectively examined AF ablations performed from 2021 to 2023 that included only PVI performed using wide antral circumferential isolation without prospective evaluation of fractionation. Retrospectively, a fractionation map was created (width 10 ms, refractory time 30 ms, roving sensitivity 0.1 mv, and threshold of 2). We evaluated the anatomic overlap between PVI lesions and fractionation in regions associated with GP. RESULTS: Among 52 patients (mean 65 (IQR 46-74) years, 82% male, and 69% paroxysmal AF), sites of fractionation corresponding to GP locations were seen in all cases. PVI ablation incidentally overlapped with fractionation in 50 (96%) patients. On average, 26% of the fractionation corresponding with GP locations were incidentally ablated. The highest proportion of fractionated areas were ablated in the left superior (36%) and right superior (31%) GP regions. More complete incidental ablation of these regions was associated with a greater intraprocedural increase in heart rate (ρ = 0.46, p < 0.001), which was subsequently associated with freedom from AF during 15.9 ± 5.2 months of follow-up. CONCLUSION: Patients undergoing AF ablation universally have fractionated electrograms corresponding to anticipated sites of GP. Partial ablation of these regions frequently occurs incidentally during PVI.

17.
J Interv Card Electrophysiol ; 67(6): 1353-1357, 2024 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-38105353

RESUMO

BACKGROUND: Pectoral nerve (PECs) blocks are established regional anesthesia techniques that can provide analgesia to the anterior chest wall. Although commonly performed preoperatively by anesthesiologists, the feasibility of electrophysiologist-performed PECs blocks from within cardiac implantable electronic device (CIED) pockets at the time of implantation has not been established. The objective of this study is to assess the feasibility of routine PECs blocks performed by the electrophysiologist from within the exposed device pocket at the time of CIED procedures. METHODS: Patients undergoing CIED procedures underwent a PECs I block (15 cc of 1% lidocaine/0.25% bupivacaine) injected between the pectoralis major and minor muscles guided by ultrasound placed in the device pocket, or PECs II block, which included a second injection (15 cc) between pectoralis minor and serratus anterior muscles. Postoperatively, pain was assessed on a numeric scale (0-10) at 1, 2, 4, and 24 h, and 2 weeks after the procedure. RESULTS: Among 20 patients (age 65 ± 16 years, 70% male, 55% with history of chronic pain), PECs I (75%) and PECs II (25%) blocks were performed. The procedures were de novo implantation (n = 17) or device revision (n = 3). The average pain score in the first 4 h was 0.4 ± 0.8 and 0.3 ± 0.6 at 24 h after the procedure. During the 24-h postoperative period, 4 patients received opioids. Two patients were discharged with opioids for pain unrelated to the procedure. CONCLUSIONS: Intraoperative PECs blocks can be feasibly performed from within an exposed pocket at the time of CIED procedures with minimal postoperative pain.


Assuntos
Desfibriladores Implantáveis , Bloqueio Nervoso , Nervos Torácicos , Ultrassonografia de Intervenção , Humanos , Masculino , Feminino , Idoso , Bloqueio Nervoso/métodos , Dor Pós-Operatória/prevenção & controle , Anestésicos Locais/administração & dosagem , Estudos de Viabilidade , Bupivacaína/administração & dosagem , Pessoa de Meia-Idade , Resultado do Tratamento , Medição da Dor , Lidocaína/administração & dosagem , Marca-Passo Artificial , Músculos Peitorais/inervação , Músculos Peitorais/cirurgia
18.
J Interv Card Electrophysiol ; 67(3): 559-569, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37592198

RESUMO

BACKGROUND: The use of a multi-electrode Optrell mapping catheter during ventricular tachycardia (VT) or premature ventricular complex (PVC) ablation procedures has not been widely reported. OBJECTIVES: We aim to describe the feasibility and safety of using the Optrell multipolar mapping catheter (MPMC) to guide catheter ablation of VT and PVCs. METHODS: We conducted a single-center, retrospective evaluation of patients who underwent VT or PVC ablation between June and November 2022 utilizing the MPMC. RESULTS: A total of 20 patients met the inclusion criteria (13 VT and 7 PVC ablations, 80% male, 61 ± 15 years). High-density mapping was performed in the VT procedures with median 2753 points [IQR 1471-17,024] collected in the endocardium and 12,830 points [IQR 2319-30,010] in the epicardium. Operators noted challenges in manipulation of the MPMC in trabeculated endocardial regions or near valve apparatus. Late potentials (LPs) were detected in 11 cases, 7 of which had evidence of isochronal crowding demonstrated during late annotation mapping. Two patients who also underwent entrainment mapping had critical circuitry confirmed in regions of isochronal crowding. In the PVC group, high-density voltage and activation mapping was performed with a median 1058 points [IQR 534-3582] collected in the endocardium. CONCLUSIONS: This novel MPMC can be used safely and effectively to create high-density maps in LV endocardium or epicardium. Limitations of the catheter include a longer wait time for matrix formation prior to starting point collection and challenges in manipulation in certain regions.


Assuntos
Ablação por Cateter , Taquicardia Ventricular , Complexos Ventriculares Prematuros , Humanos , Masculino , Feminino , Estudos Retrospectivos , Taquicardia Ventricular/diagnóstico por imagem , Taquicardia Ventricular/cirurgia , Complexos Ventriculares Prematuros/cirurgia , Eletrodos , Catéteres , Ablação por Cateter/métodos
19.
J Interv Card Electrophysiol ; 67(3): 617-623, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37700118

RESUMO

BACKGROUND: There is growing interest in the possibility of discontinuing oral anticoagulation following successful catheter ablation of atrial fibrillation (AF). However, it remains unknown whether patients can accurately detect arrhythmia recurrences following ablation. We therefore sought to characterize the accuracy of pulse checking and arrhythmia symptoms for the identification of AF following ablation. METHODS: This prospective cohort study included patients at the Hospital of the University of Pennsylvania with an insertable cardiac monitor (ICM) treated with catheter ablation for AF who recorded the results from minimum twice daily pulse checks and additionally with arrhythmia symptoms into a diary for 2 months following their procedure. Accuracy of this self-assessment protocol was determined by comparison to ICM-detected AF. RESULTS: A total of 55 patients (age 69 ± 8 years, 30 (55%) male, CHA2DS2VASc score 3.2 ± 1. 5) were included. Patients recorded a total of 5911 pulse checks, and there were 280 episodes of ICM-documented AF among 26 patients with an average duration of 2.5 ± 3.3 h. Among 362 episodes of patient-suspected AF, 134 correlated with ICM-identified AF (37% true positive rate). Of the 5549 pulse checks that did not identify AF, 196 correlated with ICM-identified AF (4% false negative rate). Twice daily pulse checking had a sensitivity of 47% and a specificity of 96% for identifying each episode of AF. CONCLUSIONS: Our data indicate that a strategy of pulse checks and symptom assessment is insufficient to identify all episodes of AF in many patients following catheter ablation.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Humanos , Masculino , Pessoa de Meia-Idade , Idoso , Feminino , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Estudos Prospectivos , Eletrocardiografia Ambulatorial/métodos , Frequência Cardíaca , Ablação por Cateter/métodos
20.
Heart Rhythm ; 2024 Sep 19.
Artigo em Inglês | MEDLINE | ID: mdl-39304007

RESUMO

BACKGROUND: Radiofrequency ablation (RFA) of cavotricuspid isthmus (CTI)-dependent atrial flutter requires ablation of the tricuspid annulus overlying the right coronary artery (RCA). Although it is considered safe, reports of acute and subacute RCA injury in human and animal studies raise the possibility of late RCA stenosis. OBJECTIVE: The objective of this study was to compare the incidence and severity of angiographic RCA stenoses in patients who have undergone CTI RFA with a control group to assess the long-term risk of RCA damage. METHODS: A 2-center retrospective case-cohort study was performed including all patients from 2002 to 2018 undergoing atrial fibrillation (AF) with CTI ablation (CTI + AF) or AF ablation alone with subsequent coronary angiography (CAG). The AF alone group served as controls because of anticipated similarity of baseline characteristics. Coronary arteries that are anatomically remote to the CTI were examined as prespecified falsification end points. CAG was scored by a blinded observer. RESULTS: There were 156 patients who underwent pulmonary vein isolation with subsequent CAG (CTI + AF, n = 81; AF alone, n = 75) with no difference in baseline characteristics including age, sex, comorbidities, and medications. Mean time from ablation to CAG was similar (CTI + AF, 5.0 ± 3.7 years; AF alone, 5.4 ± 3.9 years; P = .5). The mid and distal RCA showed no difference in the average number of angiographic stenoses or lesion severity. In regression analysis, CTI ablation was not a predictor of RCA stenosis severity (P = .6). There was no difference in coronary disease at sites remote to the CTI ablation (P = NS for all). CONCLUSION: There was no observed relationship between CTI RFA and the number or severity of angiographically apparent RCA stenoses in long-term follow-up.

SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa