Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 173
Filtrar
1.
Arterioscler Thromb Vasc Biol ; 44(5): 1065-1085, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38572650

RESUMO

Blood vessels are subjected to complex biomechanical loads, primarily from pressure-driven blood flow. Abnormal loading associated with vascular grafts, arising from altered hemodynamics or wall mechanics, can cause acute and progressive vascular failure and end-organ dysfunction. Perturbations to mechanobiological stimuli experienced by vascular cells contribute to remodeling of the vascular wall via activation of mechanosensitive signaling pathways and subsequent changes in gene expression and associated turnover of cells and extracellular matrix. In this review, we outline experimental and computational tools used to quantify metrics of biomechanical loading in vascular grafts and highlight those that show potential in predicting graft failure for diverse disease contexts. We include metrics derived from both fluid and solid mechanics that drive feedback loops between mechanobiological processes and changes in the biomechanical state that govern the natural history of vascular grafts. As illustrative examples, we consider application-specific coronary artery bypass grafts, peripheral vascular grafts, and tissue-engineered vascular grafts for congenital heart surgery as each of these involves unique circulatory environments, loading magnitudes, and graft materials.


Assuntos
Prótese Vascular , Hemodinâmica , Humanos , Animais , Modelos Cardiovasculares , Falha de Prótese , Estresse Mecânico , Fenômenos Biomecânicos , Mecanotransdução Celular , Implante de Prótese Vascular/efeitos adversos , Desenho de Prótese , Oclusão de Enxerto Vascular/fisiopatologia , Oclusão de Enxerto Vascular/etiologia , Remodelação Vascular
2.
Artigo em Inglês | MEDLINE | ID: mdl-38826864

RESUMO

Fluid-structure interaction with contact poses profound mathematical and numerical challenges, particularly when considering realistic contact scenarios and the influence of surface roughness. Computationally, contact introduces challenges in altering the fluid domain topology and preserving stress balance. This work introduces a new mathematical framework for a unified continuum description of fluid-porous-structure-contact interaction (FPSCI), leveraging the Navier-Stokes-Brinkman (NSB) equations to incorporate porous effects within the surface asperities in the contact region. Our approach maintains mechanical consistency during contact, circumventing issues associated with contact models and complex interface coupling conditions, allowing for the modeling of tangential creeping flows due to surface roughness. The unified continuum and variational multiscale formulation ensure robustness by enabling stable and unified integration of fluid, porous, and solid sub-problems. Computational efficiency and ease of implementation - key advantages of our approach - are demonstrated by solving two benchmark problems of a falling ball and an idealized heart valve. This research has broad implications for fields reliant on accurate fluid-structure interactions and promising advancements in modeling and numerical simulation techniques.

3.
Artigo em Inglês | MEDLINE | ID: mdl-38912105

RESUMO

We study the problem of multifidelity uncertainty propagation for computationally expensive models. In particular, we consider the general setting where the high-fidelity and low-fidelity models have a dissimilar parameterization both in terms of number of random inputs and their probability distributions, which can be either known in closed form or provided through samples. We derive novel multifidelity Monte Carlo estimators which rely on a shared subspace between the high-fidelity and low-fidelity models where the parameters follow the same probability distribution, i.e., a standard Gaussian. We build the shared space employing normalizing flows to map different probability distributions into a common one, together with linear and nonlinear dimensionality reduction techniques, active subspaces and autoencoders, respectively, which capture the subspaces where the models vary the most. We then compose the existing low-fidelity model with these transformations and construct modified models with an increased correlation with the high-fidelity model, which therefore yield multifidelity estimators with reduced variance. A series of numerical experiments illustrate the properties and advantages of our approaches.

4.
Artigo em Inglês | MEDLINE | ID: mdl-38523716

RESUMO

In numerical simulations of cardiac mechanics, coupling the heart to a model of the circulatory system is essential for capturing physiological cardiac behavior. A popular and efficient technique is to use an electrical circuit analogy, known as a lumped parameter network or zero-dimensional (0D) fluid model, to represent blood flow throughout the cardiovascular system. Due to the strong physical interaction between the heart and the blood circulation, developing accurate and efficient numerical coupling methods remains an active area of research. In this work, we present a modular framework for implicitly coupling three-dimensional (3D) finite element simulations of cardiac mechanics to 0D models of blood circulation. The framework is modular in that the circulation model can be modified independently of the 3D finite element solver, and vice versa. The numerical scheme builds upon a previous work that combines 3D blood flow models with 0D circulation models (3D fluid - 0D fluid). Here, we extend it to couple 3D cardiac tissue mechanics models with 0D circulation models (3D structure - 0D fluid), showing that both mathematical problems can be solved within a unified coupling scheme. The effectiveness, temporal convergence, and computational cost of the algorithm are assessed through multiple examples relevant to the cardiovascular modeling community. Importantly, in an idealized left ventricle example, we show that the coupled model yields physiological pressure-volume loops and naturally recapitulates the isovolumic contraction and relaxation phases of the cardiac cycle without any additional numerical techniques. Furthermore, we provide a new derivation of the scheme inspired by the Approximate Newton Method of Chan (1985), explaining how the proposed numerical scheme combines the stability of monolithic approaches with the modularity and flexibility of partitioned approaches.

5.
Artif Organs ; 47(7): 1133-1150, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-37042396

RESUMO

BACKGROUND: Infants with single-ventricle (SV) physiology undergo the 3-stage Fontan surgery. Norwood patients, who have completed the first stage, face the highest interstage mortality. The Berlin Heart EXCOR (BH), a pediatric pulsatile ventricular assist device, has shown promise in supporting these patients. However, clinical questions regarding device configurations prevent optimal support. METHODS: We developed a combined idealized mechanics-lumped parameter model of a Norwood patient and simulated two additional patient-specific cases: pulmonary hypertension (PH) and post-operative treatment with milrinone. We quantified the effects of BH support across different device volumes, rates, and inflow connections on patient hemodynamics and BH performance. RESULTS: Increasing device volume and rate increased cardiac output, but with unsubstantial changes in specific arterial oxygen content. We identified distinct SV-BH interactions that may impact patient myocardial health and contribute to poor clinical outcomes. Our results suggested BH settings for patients with PH and for patients treated post-operatively with milrinone. CONCLUSIONS: We present a computational model to characterize and quantify patient hemodynamics and BH support for infants with Norwood physiology. Our results emphasized that oxygen delivery does not increase with BH rate or volume, which may not meet patient needs and contribute to suboptimal clinical outcomes. Our findings demonstrated that an atrial BH may provide optimal cardiac loading for patients with diastolic dysfunction. Meanwhile, a ventricular BH decreased active stress in the myocardium and countered the effects of milrinone. Patients with PH showed greater sensitivity to device volume. In this work, we demonstrate the adaptability of our model to analyze BH support across varied clinical situations.


Assuntos
Coração Auxiliar , Milrinona , Lactente , Humanos , Criança , Milrinona/uso terapêutico , Resultado do Tratamento , Hemodinâmica , Simulação por Computador , Oxigênio , Coração Auxiliar/efeitos adversos
6.
J Biomech Eng ; 145(3)2023 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-36282508

RESUMO

We propose svMorph, a framework for interactive virtual sculpting of patient-specific vascular anatomic models. Our framework includes three tools for the creation of tortuosity, aneurysms, and stenoses in tubular vascular geometries. These shape edits are performed via geometric operations on the surface mesh and vessel centerline curves of the input model. The tortuosity tool also uses the physics-based Oriented Particles method, coupled with linear blend skinning, to achieve smooth, elastic-like deformations. Our tools can be applied separately or in combination to produce simulation-suitable morphed models. They are also compatible with popular vascular modeling software, such as simvascular. To illustrate our tools, we morph several image-based, patient-specific models to create a range of shape changes and simulate the resulting hemodynamics via three-dimensional, computational fluid dynamics. We also demonstrate the ability to quickly estimate the hemodynamic effects of the shape changes via the automated generation of associated zero-dimensional lumped-parameter models.


Assuntos
Hemodinâmica , Modelos Cardiovasculares , Humanos , Simulação por Computador , Modelos Anatômicos , Hidrodinâmica
7.
Comput Methods Appl Mech Eng ; 417(Pt B)2023 Dec 15.
Artigo em Inglês | MEDLINE | ID: mdl-38044957

RESUMO

We implement full, three-dimensional constrained mixture theory for vascular growth and remodeling into a finite element fluid-structure interaction (FSI) solver. The resulting "fluid-solid-growth" (FSG) solver allows long term, patient-specific predictions of changing hemodynamics, vessel wall morphology, tissue composition, and material properties. This extension from short term (FSI) to long term (FSG) simulations increases clinical relevance by enabling mechanobioloigcally-dependent studies of disease progression in complex domains.

8.
PLoS Comput Biol ; 17(9): e1009331, 2021 09.
Artigo em Inglês | MEDLINE | ID: mdl-34491991

RESUMO

Coronary artery thrombosis is the major risk associated with Kawasaki disease (KD). Long-term management of KD patients with persistent aneurysms requires a thrombotic risk assessment and clinical decisions regarding the administration of anticoagulation therapy. Computational fluid dynamics has demonstrated that abnormal KD coronary artery hemodynamics can be associated with thrombosis. However, the underlying mechanisms of clot formation are not yet fully understood. Here we present a new model incorporating data from patient-specific simulated velocity fields to track platelet activation and accumulation. We use a system of Reaction-Advection-Diffusion equations solved with a stabilized finite element method to describe the evolution of non-activated platelets and activated platelet concentrations [AP], local concentrations of adenosine diphosphate (ADP) and poly-phosphate (PolyP). The activation of platelets is modeled as a function of shear-rate exposure and local concentration of agonists. We compared the distribution of activated platelets in a healthy coronary case and six cases with coronary artery aneurysms caused by KD, including three with confirmed thrombosis. Results show spatial correlation between regions of higher concentration of activated platelets and the reported location of the clot, suggesting predictive capabilities of this model towards identifying regions at high risk for thrombosis. Also, the concentration levels of ADP and PolyP in cases with confirmed thrombosis are higher than the reported critical values associated with platelet aggregation (ADP) and activation of the intrinsic coagulation pathway (PolyP). These findings suggest the potential initiation of a coagulation pathway even in the absence of an extrinsic factor. Finally, computational simulations show that in regions of flow stagnation, biochemical activation, as a result of local agonist concentration, is dominant. Identifying the leading factors to a pro-coagulant environment in each case-mechanical or biochemical-could help define improved strategies for thrombosis prevention tailored for each patient.


Assuntos
Anticoagulantes/uso terapêutico , Plaquetas/patologia , Biologia Computacional/métodos , Vasos Coronários/patologia , Síndrome de Linfonodos Mucocutâneos/complicações , Trombose/complicações , Difosfato de Adenosina/química , Coagulação Sanguínea , Simulação por Computador , Humanos , Síndrome de Linfonodos Mucocutâneos/sangue , Ativação Plaquetária , Agregação Plaquetária , Trombose/sangue , Trombose/tratamento farmacológico
9.
J Cardiovasc Magn Reson ; 24(1): 59, 2022 11 14.
Artigo em Inglês | MEDLINE | ID: mdl-36372884

RESUMO

BACKGROUND: Four-dimensional flow cardiovascular magnetic resonance imaging (4D flow CMR) allows comprehensive assessment of pulmonary artery (PA) flow dynamics. Few studies have characterized longitudinal changes in pulmonary flow dynamics and right ventricular (RV) recovery following a pulmonary endarterectomy (PEA) for patients with chronic thromboembolic pulmonary hypertension (CTEPH). This can provide novel insights of RV and PA dynamics during recovery. We investigated the longitudinal trajectory of 4D flow metrics following a PEA including velocity, vorticity, helicity, and PA vessel wall stiffness. METHODS: Twenty patients with CTEPH underwent pre-PEA and > 6 months post-PEA CMR imaging including 4D flow CMR; right heart catheter measurements were performed in 18 of these patients. We developed a semi-automated pipeline to extract integrated 4D flow-derived main, left, and right PA (MPA, LPA, RPA) volumes, velocity flow profiles, and secondary flow profiles. We focused on secondary flow metrics of vorticity, volume fraction of positive helicity (clockwise rotation), and the helical flow index (HFI) that measures helicity intensity. RESULTS: Mean PA pressures (mPAP), total pulmonary resistance (TPR), and normalized RV end-systolic volume (RVESV) decreased significantly post-PEA (P < 0.002). 4D flow-derived PA volumes decreased (P < 0.001) and stiffness, velocity, and vorticity increased (P < 0.01) post-PEA. Longitudinal improvements from pre- to post-PEA in mPAP were associated with longitudinal decreases in MPA area (r = 0.68, P = 0.002). Longitudinal improvements in TPR were associated with longitudinal increases in the maximum RPA HFI (r=-0.85, P < 0.001). Longitudinal improvements in RVESV were associated with longitudinal decreases in MPA fraction of positive helicity (r = 0.75, P = 0.003) and minimum MPA HFI (r=-0.72, P = 0.005). CONCLUSION: We developed a semi-automated pipeline for analyzing 4D flow metrics of vessel stiffness and flow profiles. PEA was associated with changes in 4D flow metrics of PA flow profiles and vessel stiffness. Longitudinal analysis revealed that PA helicity was associated with pulmonary remodeling and RV reverse remodeling following a PEA.


Assuntos
Hipertensão Pulmonar , Embolia Pulmonar , Humanos , Hipertensão Pulmonar/diagnóstico por imagem , Hipertensão Pulmonar/etiologia , Hipertensão Pulmonar/cirurgia , Embolia Pulmonar/complicações , Embolia Pulmonar/diagnóstico por imagem , Embolia Pulmonar/cirurgia , Valor Preditivo dos Testes , Endarterectomia/métodos , Artéria Pulmonar/diagnóstico por imagem , Artéria Pulmonar/cirurgia , Imageamento por Ressonância Magnética , Remodelação Ventricular , Espectroscopia de Ressonância Magnética , Função Ventricular Direita
10.
Cardiol Young ; 32(7): 1122-1128, 2022 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-34558399

RESUMO

INTRODUCTION: Cardiopulmonary resuscitation (CPR) in the shunted single-ventricle population is associated with poor outcomes. Interposed abdominal compression-cardiopulmonary resuscitation, or IAC-CPR, is an adjunct to standard CPR in which pressure is applied to the abdomen during the recoil phase of chest compressions. METHODS: A lumped parameter model that represents heart chambers and blood vessels as resistors and capacitors was used to simulate blood flow in both Blalock-Taussig-Thomas and Sano circulations. For standard CPR, a prescribed external pressure waveform was applied to the heart chambers and great vessels to simulate chest compressions. IAC-CPR was modelled by adding phasic compression pressure to the abdominal aorta. Differential equations for the model were solved by a Runge-Kutta method. RESULTS: In the Blalock-Taussig-Thomas model, mean pulmonary blood flow during IAC-CPR was 30% higher than during standard CPR; cardiac output increased 21%, diastolic blood pressure 16%, systolic blood pressure 8%, coronary perfusion pressure 17%, and coronary blood flow 17%. In the Sano model, pulmonary blood flow during IAC-CPR increased 150%, whereas cardiac output was improved by 13%, diastolic blood pressure 18%, systolic blood pressure 8%, coronary perfusion pressure 15%, and coronary blood flow 14%. CONCLUSIONS: In this model, IAC-CPR confers significant advantage over standard CPR with respect to pulmonary blood flow, cardiac output, blood pressure, coronary perfusion pressure, and coronary blood flow. These results support the notion that single-ventricle paediatric patients may benefit from adjunctive resuscitation techniques, and underscores the need for an in-vivo trial of IAC-CPR in children.


Assuntos
Reanimação Cardiopulmonar , Abdome , Reanimação Cardiopulmonar/métodos , Criança , Hemodinâmica , Humanos , Modelos Teóricos , Pressão
11.
Artigo em Inglês | MEDLINE | ID: mdl-34737480

RESUMO

We propose a novel approach to generate samples from the conditional distribution of patient-specific cardiovascular models given a clinically aquired image volume. A convolutional neural network architecture with dropout layers is first trained for vessel lumen segmentation using a regression approach, to enable Bayesian estimation of vessel lumen surfaces. This network is then integrated into a path-planning patient-specific modeling pipeline to generate families of cardiovascular models. We demonstrate our approach by quantifying the effect of geometric uncertainty on the hemodynamics for three patient-specific anatomies, an aorto-iliac bifurcation, an abdominal aortic aneurysm and a sub-model of the left coronary arteries. A key innovation introduced in the proposed approach is the ability to learn geometric uncertainty directly from training data. The results show how geometric uncertainty produces coefficients of variation comparable to or larger than other sources of uncertainty for wall shear stress and velocity magnitude, but has limited impact on pressure. Specifically, this is true for anatomies characterized by small vessel sizes, and for local vessel lesions seen infrequently during network training.

12.
Artigo em Inglês | MEDLINE | ID: mdl-34176992

RESUMO

We are interested in a reduced order method for the efficient simulation of blood flow in arteries. The blood dynamics is modeled by means of the incompressible Navier-Stokes equations. Our algorithm is based on an approximated domain-decomposition of the target geometry into a number of subdomains obtained from the parametrized deformation of geometrical building blocks (e.g., straight tubes and model bifurcations). On each of these building blocks, we build a set of spectral functions by Proper Orthogonal Decomposition of a large number of snapshots of finite element solutions (offline phase). The global solution of the Navier-Stokes equations on a target geometry is then found by coupling linear combinations of these local basis functions by means of spectral Lagrange multipliers (online phase). Being that the number of reduced degrees of freedom is considerably smaller than their finite element counterpart, this approach allows us to significantly decrease the size of the linear system to be solved in each iteration of the Newton-Raphson algorithm. We achieve large speedups with respect to the full order simulation (in our numerical experiments, the gain is at least of one order of magnitude and grows inversely with respect to the reduced basis size), whilst still retaining satisfactory accuracy for most cardiovascular simulations.

13.
Am J Physiol Heart Circ Physiol ; 319(2): H432-H442, 2020 08 01.
Artigo em Inglês | MEDLINE | ID: mdl-32618514

RESUMO

Pulmonary artery (PA) morphometry has been extensively explored in adults, with particular focus on intra-acinar arteries. However, scaling law relationships for length and diameter of extensive preacinar PAs by age have not been previously reported for in vivo human data. To understand preacinar PA growth spanning children to adults, we performed morphometric analyses of all PAs visible in the computed tomography (CT) and magnetic resonance (MR) images from a healthy subject cohort [n = 16; age: 1-51 yr; body surface area (BSA): 0.49-2.01 m2]. Subject-specific anatomic PA models were constructed from CT and MR images, and morphometric information-diameter, length, tortuosity, bifurcation angle, and connectivity-was extracted and sorted into diameter-defined Strahler orders. Validation of Murray's law, describing optimal scaling exponents of radii for branching vessels, was performed to determine how closely PAs conform to this classical relationship. Using regression analyses of vessel diameters and lengths against orders and patient metrics (BSA, age, height), we found that diameters increased exponentially with order and allometrically with patient metrics. Length increased allometrically with patient metrics, albeit weakly. The average tortuosity index of all vessels was 0.026 ± 0.024, average bifurcation angle was 28.2 ± 15.1°, and average Murray's law exponent was 2.92 ± 1.07. We report a set of scaling laws for vessel diameter and length, along with other morphometric information. These provide an initial understanding of healthy structural preacinar PA development with age, which can be used for computational modeling studies and comparison with diseased PA anatomy.NEW & NOTEWORTHY Pulmonary artery (PA) morphometry studies to date have focused primarily on large arteries and intra-acinar arteries in either adults or children, neglecting preacinar arteries in both populations. Our study is the first to quantify in vivo preacinar PA morphometry changes spanning infants to adults. For preacinar arteries > 1 mm in diameter, we identify scaling laws for vessel diameters and lengths with patient metrics of growth and establish a healthy PA morphometry baseline for most preacinar PAs.


Assuntos
Envelhecimento , Angiografia por Tomografia Computadorizada , Angiografia por Ressonância Magnética , Modelos Cardiovasculares , Modelagem Computacional Específica para o Paciente , Artéria Pulmonar/diagnóstico por imagem , Artéria Pulmonar/crescimento & desenvolvimento , Adolescente , Adulto , Fatores Etários , Estatura , Superfície Corporal , Criança , Pré-Escolar , Feminino , Humanos , Lactente , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Reprodutibilidade dos Testes , Adulto Jovem
14.
J Biomech Eng ; 142(2)2020 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-31074768

RESUMO

Wall shear stress (WSS) has been shown to be associated with myocardial infarction (MI) and progression of atherosclerosis. Wall elasticity is an important feature of hemodynamic modeling affecting WSS calculations. The objective of this study was to investigate the role of wall elasticity on WSS, and justify use of either rigid or elastic models in future studies. Digital anatomic models of the aorta and coronaries were created based on coronary computed tomography angiography (CCTA) in four patients. Hemodynamics was computed in rigid and elastic models using a finite element flow solver. WSS in five timepoints in the cardiac cycle and time averaged wall shear stress (TAWSS) were compared between the models at each 3 mm subsegment and 4 arcs in cross sections along the centerlines of coronaries. In the left main (LM), proximal left anterior descending (LAD), left circumflex (LCX), and proximal right coronary artery (RCA) of the elastic model, the mean percent radial increase 5.95 ± 1.25, 4.02 ± 0.97, 4.08 ± 0.94, and 4.84 ± 1.05%, respectively. WSS at each timepoint in the cardiac cycle had slightly different values; however, when averaged over the cardiac cycle, there were negligible differences between the models. In both the subsegments (n = 704) and subarc analysis, TAWSS in the two models were highly correlated (r = 0.99). In investigation on the effect of coronary wall elasticity on WSS in CCTA-based models, the results of this study show no significant differences in TAWSS justifying using rigid wall models for future larger studies.


Assuntos
Vasos Coronários , Hemodinâmica , Doença da Artéria Coronariana , Elasticidade , Humanos , Modelos Cardiovasculares , Resistência ao Cisalhamento , Estresse Mecânico
15.
J Biomech Eng ; 142(11)2020 11 01.
Artigo em Inglês | MEDLINE | ID: mdl-32529203

RESUMO

Computational modeling of cardiovascular flows is becoming increasingly important in a range of biomedical applications, and understanding the fundamentals of computational modeling is important for engineering students. In addition to their purpose as research tools, integrated image-based computational fluid dynamics (CFD) platforms can be used to teach the fundamental principles involved in computational modeling and generate interest in studying cardiovascular disease. We report the results of a study performed at five institutions designed to investigate the effectiveness of an integrated modeling platform as an instructional tool and describe "best practices" for using an integrated modeling platform in the classroom. Use of an integrated modeling platform as an instructional tool in nontraditional educational settings (workshops, study abroad programs, in outreach) is also discussed. Results of the study show statistically significant improvements in understanding after using the integrated modeling platform, suggesting such platforms can be effective tools for teaching fundamental cardiovascular computational modeling principles.


Assuntos
Hidrodinâmica , Software , Simulação por Computador , Modelos Cardiovasculares
16.
Artigo em Inglês | MEDLINE | ID: mdl-32675836

RESUMO

We develop a novel iterative solution method for the incompressible Navier-Stokes equations with boundary conditions coupled with reduced models. The iterative algorithm is designed based on the variational multiscale formulation and the generalized-α scheme. The spatiotemporal discretization leads to a block structure of the resulting consistent tangent matrix in the Newton-Raphson procedure. As a generalization of the conventional block preconditioners, a three-level nested block preconditioner is introduced to attain a better representation of the Schur complement, which plays a key role in the overall algorithm robustness and efficiency. This approach provides a flexible, algorithmic way to handle the Schur complement for problems involving multiscale and multiphysics coupling. The solution method is implemented and benchmarked against experimental data from the nozzle challenge problem issued by the US Food and Drug Administration. The robustness, efficiency, and parallel scalability of the proposed technique are then examined in several settings, including moderately high Reynolds number flows and physiological flows with strong resistance effect due to coupled downstream vasculature models. Two patient-specific hemodynamic simulations, covering systemic and pulmonary flows, are performed to further corroborate the efficacy of the proposed methodology.

17.
Artigo em Inglês | MEDLINE | ID: mdl-32336811

RESUMO

Standard approaches for uncertainty quantification in cardiovascular modeling pose challenges due to the large number of uncertain inputs and the significant computational cost of realistic three-dimensional simulations. We propose an efficient uncertainty quantification framework utilizing a multilevel multifidelity Monte Carlo (MLMF) estimator to improve the accuracy of hemodynamic quantities of interest while maintaining reasonable computational cost. This is achieved by leveraging three cardiovascular model fidelities, each with varying spatial resolution to rigorously quantify the variability in hemodynamic outputs. We employ two low-fidelity models (zero- and one-dimensional) to construct several different estimators. Our goal is to investigate and compare the efficiency of estimators built from combinations of these two low-fidelity model alternatives and our high-fidelity three-dimensional models. We demonstrate this framework on healthy and diseased models of aortic and coronary anatomy, including uncertainties in material property and boundary condition parameters. Our goal is to demonstrate that for this application it is possible to accelerate the convergence of the estimators by utilizing a MLMF paradigm. Therefore, we compare our approach to single fidelity Monte Carlo estimators and to a multilevel Monte Carlo approach based only on three-dimensional simulations, but leveraging multiple spatial resolutions. We demonstrate significant, on the order of 10 to 100 times, reduction in total computational cost with the MLMF estimators. We also examine the differing properties of the MLMF estimators in healthy versus diseased models, as well as global versus local quantities of interest. As expected, global quantities such as outlet pressure and flow show larger reductions than local quantities, such as those relating to wall shear stress, as the latter rely more heavily on the highest fidelity model evaluations. Similarly, healthy models show larger reductions than diseased models. In all cases, our workflow coupling Dakota's MLMF estimators with the SimVascular cardiovascular modeling framework makes uncertainty quantification feasible for constrained computational budgets.

18.
Mech Res Commun ; 1072020 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-32773906

RESUMO

In this work, we present a computational fluid-structure interaction (FSI) study for a healthy patient-specific pulmonary arterial tree using the unified continuum and variational multiscale (VMS) formulation we previously developed. The unified framework is particularly well-suited for FSI, as the fluid and solid sub-problems are addressed in essentially the same manner and can thus be uniformly integrated in time with the generalized-α method. In addition, the VMS formulation provides a mechanism for large-eddy simulation in the fluid sub-problem and pressure stabilization in the solid sub-problem. The FSI problem is solved in a quasi-direct approach, in which the pressure and velocity in the unified continuum body are first solved, and the solid displacement is then obtained via a segregated algorithm and prescribed as a boundary condition for the mesh motion. Results of the pulmonary arterial FSI simulation are presented and compared against those of a rigid wall simulation.

SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa