Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 109
Filtrar
1.
Europace ; 26(3)2024 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-38375690

RESUMO

AIMS: Late gadolinium enhancement cardiac magnetic resonance (LGE-CMR) detects myocardial scarring, a risk factor for ventricular arrhythmias (VAs) in hypertrophic cardiomyopathy (HCM). The LGE-CMR distinguishes core, borderzone (BZ) fibrosis, and BZ channels, crucial components of re-entry circuits. We studied how scar architecture affects inducibility and electrophysiological traits of VA in HCM. METHODS AND RESULTS: We correlated scar composition with programmed ventricular stimulation-inducible VA features using LGE intensity maps. Thirty consecutive patients were enrolled. Thirteen (43%) were non-inducible, 6 (20%) had inducible non-sustained, and 11 (37%) had inducible sustained mono (MMVT)- or polymorphic VT/VF (PVT/VF). Of 17 induced VA, 13 (76%) were MMVT that either ended spontaneously, persisted as sustained monomorphic, or degenerated into PVT/VF. Twenty-seven patients (90%) had LGE. Of these, 17 (57%) had non-sustained or sustained inducible VA. Scar mass significantly increased (P = 0.002) from non-inducible to inducible non-sustained and sustained VA patients in both the BZ and core components. Borderzone channels were found in 23%, 67%, and 91% of non-inducible, inducible non-sustained, and inducible sustained VA patients (P = 0.003). All 13 patients induced with MMVT or monomorphic-initiated PVT/VF had LGE. The origin of 10/13 of these VTs matched scar location, with 8/10 of these LGE regions showing BZ channels. During follow-up (20 months, interquartile range: 7-37), one patient with BZ channels and inducible PVT had an ICD shock for VF. CONCLUSION: Scar architecture determines inducibility and electrophysiological traits of VA in HCM. Larger studies should explore the role of complex LGE patterns in refining risk assessment in HCM patients.


Assuntos
Cardiomiopatia Hipertrófica , Canal de Sódio Disparado por Voltagem NAV1.5/deficiência , Taquicardia Ventricular , Fibrilação Ventricular , Humanos , Cicatriz/complicações , Cicatriz/patologia , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/etiologia , Meios de Contraste , Gadolínio/farmacologia , Cardiomiopatia Hipertrófica/complicações , Cardiomiopatia Hipertrófica/diagnóstico por imagem , Arritmias Cardíacas/etiologia , Arritmias Cardíacas/complicações
2.
Europace ; 26(4)2024 Mar 30.
Artigo em Inglês | MEDLINE | ID: mdl-38652090

RESUMO

AIMS: Pulmonary vein isolation (PVI) for paroxysmal atrial fibrillation (PAF) using very high-power short-duration (vHPSD) radiofrequency (RF) ablation proved to be safe and effective. However, vHPSD applications result in shallower lesions that might not be always transmural. Multidetector computed tomography-derived left atrial wall thickness (LAWT) maps could enable a thickness-guided switching from vHPSD to the standard-power ablation mode. The aim of this randomized trial was to compare the safety, the efficacy, and the efficiency of a LAWT-guided vHPSD PVI approach with those of the CLOSE protocol for PAF ablation (NCT04298177). METHODS AND RESULTS: Consecutive patients referred for first-time PAF ablation were randomized on a 1:1 basis. In the QDOT-by-LAWT arm, for LAWT ≤2.5 mm, vHPSD ablation was performed; for points with LAWT > 2.5 mm, standard-power RF ablation titrating ablation index (AI) according to the local LAWT was performed. In the CLOSE arm, LAWT information was not available to the operator; ablation was performed according to the CLOSE study settings: AI ≥400 at the posterior wall and ≥550 at the anterior wall. A total of 162 patients were included. In the QDOT-by-LAWT group, a significant reduction in procedure time (40 vs. 70 min; P < 0.001) and RF time (6.6 vs. 25.7 min; P < 0.001) was observed. No difference was observed between the groups regarding complication rate (P = 0.99) and first-pass isolation (P = 0.99). At 12-month follow-up, no significant differences occurred in atrial arrhythmia-free survival between groups (P = 0.88). CONCLUSION: LAWT-guided PVI combining vHPSD and standard-power ablation is not inferior to the CLOSE protocol in terms of 1-year atrial arrhythmia-free survival and demonstrated a reduction in procedural and RF times.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Átrios do Coração , Tomografia Computadorizada Multidetectores , Veias Pulmonares , Humanos , Veias Pulmonares/cirurgia , Veias Pulmonares/diagnóstico por imagem , Fibrilação Atrial/cirurgia , Fibrilação Atrial/fisiopatologia , Feminino , Masculino , Ablação por Cateter/métodos , Pessoa de Meia-Idade , Idoso , Átrios do Coração/cirurgia , Átrios do Coração/diagnóstico por imagem , Fatores de Tempo , Resultado do Tratamento , Recidiva , Frequência Cardíaca , Potenciais de Ação
3.
Eur Radiol ; 33(10): 6948-6958, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37195432

RESUMO

OBJECTIVES: To evaluate at 1.5 and 3 T MRI the safety and performance of trademarked ENO®, TEO®, or OTO® pacing systems with automated MRI Mode and the image quality of non-enhanced MR examinations. METHODS: A total of 267 implanted patients underwent MRI examination (brain, cardiac, shoulder, cervical spine) at 1.5 (n = 126) or 3 T (n = 141). MRI-related device complications, lead electrical performances stability at 1-month post-MRI, proper functioning of the automated MRI mode and image quality were evaluated. RESULTS: Freedom from MRI-related complications at 1 month post-MRI was 100% in both 1.5 and 3 T arms (both p < 0.0001). The stability of pacing capture threshold was respectively at 1.5 and 3 T (atrial:: 98.9% (p = 0.001) and 100% (p < 0.0001); ventricular: both 100% (p < 0001)). The stability of sensing was respectively at 1.5 and 3 T (atrial: 100% (p = 0.0001) and 96.9% (p = 0.01); ventricular: 100% (p < 0.0001) and 99.1% (p = 0.0001)). All devices switched automatically to the programmed asynchronous mode in the MRI environment and to initially programmed mode after the MRI exam. While all MR examinations were assessed as interpretable, artifacts deteriorated a subset of examinations including mostly cardiac and shoulder ones. CONCLUSION: This study demonstrates the safety and electrical stability of ENO®, TEO®, or OTO® pacing systems at 1 month post-MRI at 1.5 and 3 T. Even if artifacts were noticed in a subset of examinations, overall interpretability was preserved. CLINICAL RELEVANCE STATEMENT: ENO®, TEO®, and OTO® pacing systems switch to MR-mode when detecting magnetic field and switch back on conventional mode after MRI. Their safety and electrical stability at 1 month post MRI were shown at 1.5 and 3 T. Overall interpretability was preserved. KEY POINTS: • Patients implanted with an MRI conditional cardiac pacemaker can be safely scanned under 1.5 or 3 Tesla MRI with preserved interpretability. • Electrical parameters of the MRI conditional pacing system remain stable after a 1.5 or 3 Tesla MRI scan. • The automated MRI mode enabled the automatic switch to asynchronous mode in the MRI environment and to initial settings after the MRI scan in all patients.


Assuntos
Fibrilação Atrial , Marca-Passo Artificial , Humanos , Segurança de Equipamentos/métodos , Estudos Prospectivos , Imageamento por Ressonância Magnética/métodos
4.
Europace ; 25(12)2023 12 06.
Artigo em Inglês | MEDLINE | ID: mdl-38011712

RESUMO

AIMS: Epicardial adipose tissue might promote atrial fibrillation (AF) in several ways, including infiltrating the underlying atrial myocardium. However, the role of this potential mechanism has been poorly investigated. The aim of this study is to evaluate the presence of left atrial (LA) infiltrated adipose tissue (inFAT) by analysing multi-detector computer tomography (MDCT)-derived three-dimensional (3D) fat infiltration maps and to compare the extent of LA inFAT between patients without AF history, with paroxysmal, and with persistent AF. METHODS AND RESULTS: Sixty consecutive patients with AF diagnosis (30 persistent and 30 paroxysmal) were enrolled and compared with 20 age-matched control; MDCT-derived images were post-processed to obtain 3D LA inFAT maps for all patients. Volume (mL) and mean signal intensities [(Hounsfield Units (HU)] of inFAT (HU -194; -5), dense inFAT (HU -194; -50), and fat-myocardial admixture (HU -50; -5) were automatically computed by the software. inFAT volume was significantly different across the three groups (P = 0.009), with post-hoc pairwise comparisons showing a significant increase in inFAT volume in persistent AF compared to controls (P = 0.006). Dense inFAT retained a significant difference also after correcting for body mass index (P = 0.028). In addition, more negative inFAT radiodensity values were found in AF patients. Regional distribution analysis showed a significantly higher regional distribution of LA inFAT at left and right superior pulmonary vein antra in AF patients. CONCLUSION: Persistent forms of AF are associated with greater degree of LA intramyocardial adipose infiltration, independently of body mass index. Compared to controls, AF patients present higher LA inFAT volume at left and right superior pulmonary vein antra.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Ablação por Cateter , Humanos , Fibrilação Atrial/diagnóstico , Átrios do Coração/diagnóstico por imagem , Angiografia por Tomografia Computadorizada , Angiografia , Ablação por Cateter/métodos
5.
Europace ; 25(5)2023 05 19.
Artigo em Inglês | MEDLINE | ID: mdl-37125968

RESUMO

AIMS: Pulmonary vein (PV) antrum isolation proved to be effective for treating persistent atrial fibrillation (PeAF). We sought to investigate the results of a personalized approach aimed at adapting the ablation index (AI) to the local left atrial wall thickness (LAWT) in a cohort of consecutive patients with PeAF. METHODS AND RESULTS: Consecutive patients referred for PeAF first ablation were prospectively enrolled. The LAWT three-dimensional maps were obtained from pre-procedure multidetector computed tomography and integrated into the navigation system. Ablation index was titrated according to the local LAWT, and the ablation line was personalized to avoid the thickest regions while encircling the PV antrum. A total of 121 patients (69.4% male, age 64.5 ± 9.5 years) were included. Procedure time was 57 min (IQR 50-67), fluoroscopy time was 43 s (IQR 20-71), and radiofrequency (RF) time was 16.5 min (IQR 14.3-18.4). The median AI tailored to the local LAWT was 387 (IQR 360-410) for the anterior wall and 335 (IQR 300-375) for the posterior wall. First-pass PV antrum isolation was obtained in 103 (85%) of the right PVs and 103 (85%) of the left PVs. Median LAWT values were higher for PVs without first-pass isolation as compared to the whole cohort (P = 0.02 for left PVs and P = 0.03 for right PVs). Recurrence-free survival was 79% at 12 month follow-up. CONCLUSION: In this prospective study, LAWT-guided PV antrum isolation for PeAF was effective and efficient, requiring low procedure, fluoroscopy, and RF time. A randomized trial comparing the LAWT-guided ablation with the standard of practice is in progress (ClinicalTrials.gov, NCT05396534).


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Humanos , Masculino , Pessoa de Meia-Idade , Idoso , Feminino , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/cirurgia , Veias Pulmonares/diagnóstico por imagem , Veias Pulmonares/cirurgia , Estudos Prospectivos , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Átrios do Coração/diagnóstico por imagem , Átrios do Coração/cirurgia , Resultado do Tratamento
6.
Europace ; 25(4): 1284-1295, 2023 04 15.
Artigo em Inglês | MEDLINE | ID: mdl-36879464

RESUMO

The EU Horizon 2020 Framework-funded Standardized Treatment and Outcome Platform for Stereotactic Therapy Of Re-entrant tachycardia by a Multidisciplinary (STOPSTORM) consortium has been established as a large research network for investigating STereotactic Arrhythmia Radioablation (STAR) for ventricular tachycardia (VT). The aim is to provide a pooled treatment database to evaluate patterns of practice and outcomes of STAR and finally to harmonize STAR within Europe. The consortium comprises 31 clinical and research institutions. The project is divided into nine work packages (WPs): (i) observational cohort; (ii) standardization and harmonization of target delineation; (iii) harmonized prospective cohort; (iv) quality assurance (QA); (v) analysis and evaluation; (vi, ix) ethics and regulations; and (vii, viii) project coordination and dissemination. To provide a review of current clinical STAR practice in Europe, a comprehensive questionnaire was performed at project start. The STOPSTORM Institutions' experience in VT catheter ablation (83% ≥ 20 ann.) and stereotactic body radiotherapy (59% > 200 ann.) was adequate, and 84 STAR treatments were performed until project launch, while 8/22 centres already recruited VT patients in national clinical trials. The majority currently base their target definition on mapping during VT (96%) and/or pace mapping (75%), reduced voltage areas (63%), or late ventricular potentials (75%) during sinus rhythm. The majority currently apply a single-fraction dose of 25 Gy while planning techniques and dose prescription methods vary greatly. The current clinical STAR practice in the STOPSTORM consortium highlights potential areas of optimization and harmonization for substrate mapping, target delineation, motion management, dosimetry, and QA, which will be addressed in the various WPs.


Assuntos
Ablação por Cateter , Taquicardia Ventricular , Humanos , Estudos Prospectivos , Arritmias Cardíacas , Ventrículos do Coração , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Resultado do Tratamento
7.
Europace ; 23(3): 456-463, 2021 03 08.
Artigo em Inglês | MEDLINE | ID: mdl-33595062

RESUMO

AIMS: During the COVID-19 pandemic, concern regarding its effect on the management of non-communicable diseases has been raised. However, there are no data on the impact on cardiac implantable electronic devices (CIED) implantation rates. We aimed to determine the impact of SARS-CoV2 on the monthly incidence rates and type of pacemaker (PM) and implantable cardiac defibrillator (ICD) implantations in Catalonia before and after the declaration of the state of alarm in Spain on 14 March 2020. METHODS AND RESULTS: Data on new CIED implantations for 2017-20 were prospectively collected by nine hospitals in Catalonia. A mixed model with random intercepts corrected for time was used to estimate the change in monthly CIED implantations. Compared to the pre-COVID-19 period, an absolute decrease of 56.5% was observed (54.7% in PM and 63.7% in ICD) in CIED implantation rates. Total CIED implantations for 2017-19 and January and February 2020 was 250/month (>195 PM and >55 ICD), decreasing to 207 (161 PM and 46 ICD) in March and 131 (108 PM and 23 ICD) in April 2020. In April 2020, there was a significant fall of 185.25 CIED implantations compared to 2018 [95% confidence interval (CI) 129.6-240.9; P < 0.001] and of 188 CIED compared to 2019 (95% CI 132.3-243.7; P < 0.001). No significant differences in the type of PM or ICD were observed, nor in the indication for primary or secondary prevention. CONCLUSIONS: During the first wave of the COVID-19 pandemic, a substantial decrease in CIED implantations was observed in Catalonia. Our findings call for measures to avoid long-term social impact.


Assuntos
COVID-19 , Desfibriladores Implantáveis/tendências , Marca-Passo Artificial/tendências , Padrões de Prática Médica/tendências , Implantação de Prótese/tendências , Humanos , Segurança do Paciente , Estudos Prospectivos , Implantação de Prótese/instrumentação , Espanha , Fatores de Tempo
8.
Curr Cardiol Rep ; 23(3): 20, 2021 02 20.
Artigo em Inglês | MEDLINE | ID: mdl-33611699

RESUMO

PURPOSE OF REVIEW: Obstructive sleep apnea syndrome (OSAS) has a high prevalence in western countries. Many papers have been published with the purpose of demonstrating that OSAS acts as an arrhythmia trigger and is responsible for an increase in cardiovascular morbidity and mortality. The aim of this study was to review our knowledge on this topic. RECENT FINDINGS: There is a lot of evidence demonstrating the relationship between OSAS and arrhythmias, but there remains a lack of an interventional randomized trial to demonstrate that by treating OSAS we can reduce arrhythmia burden. OSAS is a highly prevalent illness in western countries and is clearly related to an increase in cardiovascular mortality and morbidity. Cardiac arrhythmias are triggered by a repetitive hypoxemia, hypercapnia, acidosis, intrathoracic pressure fluctuations, reoxygenation, and arousals during apnea and hypopnea episodes. Early diagnosis and treatment of these patients can reduce further cardiovascular morbidity and mortality.


Assuntos
Apneia Obstrutiva do Sono , Arritmias Cardíacas/etiologia , Humanos , Hipóxia , Prevalência , Apneia Obstrutiva do Sono/complicações
9.
Int J Mol Sci ; 22(19)2021 Sep 26.
Artigo em Inglês | MEDLINE | ID: mdl-34638717

RESUMO

MicroRNAs (miRNAs) participate in atrial remodeling and atrial fibrillation (AF) promotion. We determined the circulating miRNA profile in patients with AF and heart failure with reduced ejection fraction (HFrEF), and its potential role in promoting the arrhythmia. In plasma of 98 patients with HFrEF (49 with AF and 49 in sinus rhythm, SR), differential miRNA expression was determined by high-throughput microarray analysis followed by replication of selected candidates. Validated miRNAs were determined in human atrial samples, and potential arrhythmogenic mechanisms studied in HL-1 cells. Circulating miR-199a-5p and miR-22-5p were significantly increased in HFrEF patients with AF versus those with HFrEF in SR. Both miRNAs, but particularly miR-199a-5p, were increased in atrial samples of patients with AF. Overexpression of both miRNAs in HL-1 cells resulted in decreased protein levels of L-type Ca2+ channel, NCX and connexin-40, leading to lower basal intracellular Ca2+ levels, fewer inward currents, a moderate reduction in Ca2+ buffering post-caffeine exposure, and a deficient cell-to-cell communication. In conclusion, circulating miR-199a-5p and miR-22-5p are higher in HFrEF patients with AF, with similar findings in human atrial samples of AF patients. Cells exposed to both miRNAs exhibited altered Ca2+ handling and defective cell-to-cell communication, both findings being potential arrhythmogenic mechanisms.


Assuntos
Fibrilação Atrial/sangue , Sinalização do Cálcio , Comunicação Celular , MicroRNA Circulante/sangue , Insuficiência Cardíaca/sangue , MicroRNAs/sangue , Idoso , Idoso de 80 Anos ou mais , Fibrilação Atrial/etiologia , Linhagem Celular , Feminino , Insuficiência Cardíaca/complicações , Humanos , Masculino
10.
J Cardiovasc Electrophysiol ; 31(7): 1649-1657, 2020 07.
Artigo em Inglês | MEDLINE | ID: mdl-32400073

RESUMO

BACKGROUND: The diagnostic accuracy of incremental atrial pacing (IP) to determine complete cavo-tricuspid isthmus (CTI) block during typical atrial flutter (AFL) ablation is limited by both an extensive/nonlinear ablation and/or the presence of intra-atrial conduction delay elsewhere in the right atrium. We examined the diagnostic performance of an IP variant based on the assessment of the atrial potentials adjacent to the ablation line which aims at overcoming both limitations. METHODS: From a prospective population of 108 consecutive patients, 15 were excluded due to observation of inconclusive CTI ablation potentials precluding for a straight comparison between the IP maneuver and its variant. In the remaining 93, IP was performed from the low lateral right atrium and the coronary sinus ostium, with the ablation catheter positioned both at the CTI line and adjacent (<5 mm) to its septal and lateral aspect. The IP variant consisted of measuring the interval between the two atrial electrograms situated on the same side of the ablation line, opposite to the pacing site, a ≤10 ms increase indicating complete CTI block. RESULTS: The IP maneuver and its variant were consistent with complete CTI block in 82/93 (88%) and 87/93 (93%) patients, respectively. Four patients had AFL recurrence during follow-up: 2/4 and 4/4 had been adequately classified as incomplete block by the IP maneuver and its variant, respectively. Twenty-three patients (24%) had significant intra-atrial conduction delay elsewhere in the right atrium. The IP maneuver and its variant were suggestive of an incomplete CTI block in 11/23 and 4/23 in this setting (P = .028), with the later best predicting subsequent AFL relapses (2/12 vs 2/4, P = .01). CONCLUSIONS: The IP variant, which was designed to overcome the limitations of the conventional IP maneuver, accurately distinguishes complete from incomplete CTI block and helps to predict AFL recurrences after ablation.


Assuntos
Flutter Atrial , Ablação por Cateter , Flutter Atrial/diagnóstico , Flutter Atrial/cirurgia , Técnicas Eletrofisiológicas Cardíacas , Humanos , Estudos Prospectivos , Resultado do Tratamento
11.
Europace ; 22(9): 1391-1400, 2020 09 01.
Artigo em Inglês | MEDLINE | ID: mdl-32898254

RESUMO

AIMS: Sudden cardiac death (SCD) risk estimation in patients referred for cardiac resynchronization therapy (CRT) remains a challenge. By CRT-mediated improvement of left ventricular ejection fraction (LVEF), many patients loose indication for primary prevention implantable cardioverter-defibrillator (ICD). Increasing evidence shows the importance of myocardial scar for risk prediction. The aim of this study was to investigate the prognostic impact of myocardial scar depending on the echocardiographic response in patients undergoing CRT. METHODS AND RESULTS: Patients with indication for CRT were prospectively enrolled. Decision about ICD or pacemaker implantation was based on clinical criteria. All patients underwent delayed-enhancement cardiac magnetic resonance imaging. Median follow-up duration was 45 (24-75) months. Primary outcome was a composite of sustained ventricular arrhythmia, appropriate ICD therapy, or SCD. A total of 218 patients with LVEF 25.5 ± 6.6% were analysed [158 (73%) male, 64.9 ± 10.7 years]. Myocardial scar was observed in 73 patients with ischaemic cardiomyopathy (ICM) (95% of ICM patients); in 62 with non-ischaemic cardiomyopathy (45% of these patients); and in all but 1 of 36 (17%) patients who reached the primary outcome. Myocardial scar was the only significant predictor of primary outcome [odds ratio 27.7 (3.8-202.7)], independent of echocardiographic CRT response. A total of 55 (25%) patients died from any cause or received heart transplant. For overall survival, only a combination of the absence of myocardial scar with CRT response was associated with favourable outcome. CONCLUSION: Malignant arrhythmic events and SCD depend on the presence of myocardial scar but not on CRT response. All-cause mortality improved only with the combined absence of myocardial scar and CRT response.


Assuntos
Terapia de Ressincronização Cardíaca , Desfibriladores Implantáveis , Insuficiência Cardíaca , Arritmias Cardíacas , Cicatriz/diagnóstico por imagem , Cicatriz/patologia , Morte Súbita Cardíaca/prevenção & controle , Insuficiência Cardíaca/terapia , Humanos , Masculino , Fatores de Risco , Volume Sistólico , Resultado do Tratamento , Função Ventricular Esquerda
12.
Europace ; 22(2): 274-280, 2020 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-31942618

RESUMO

AIMS: Frequent premature ventricular complexes (PVCs) can induce or worsen left ventricular systolic dysfunction. We aimed to investigate the influence of the baseline QRS in the response after PVC ablation in patients with depressed left ventricular ejection fraction (LVEF). METHODS AND RESULTS: Two hundred and fifteen [59 ± 13 years old, 152 (71%) men] consecutive patients with left ventricular (LV) systolic dysfunction and frequent PVCs referred for ablation were included and followed-up for 12 months. Echocardiographic response was defined as an improvement of at least five absolute points in LVEF. Clinical, electrocardiogram, and electrophysiological characteristics were analysed. Mean baseline QRS duration was 110 ms [97-140]. Premature ventricular complex burden significantly decreased after ablation from 23% [16-33] at baseline to 1% [0-8] at 12 months, P < 0.001. Mean PVC burden reduction was 18 [8-30] points. There was a significant improvement of LVEF from 35% [29-40] at baseline to 44% [35-55] at 12 months, P < 0.001. One hundred and thirty (61%) patients were considered as echocardiographic responders. Baseline QRS duration (ms) [odds ratio (OR) 0.98 (0.97-0.99), P = 0.01] was an independent predictor of echocardiographic response. Mean LVEF improvement was 16 [10-21] points when the baseline QRS duration was <90 ms; 12 [4-20] when it was 90-110 ms; 5 [0-15] when it was 110 ± 130 ms; and 0 [0-6] points when it was >130 ms. CONCLUSIONS: In patients with LV systolic dysfunction, intrinsic QRS duration is inversely related to the probability and the degree of echocardiographic response after frequent PVC ablation. Patients with a QRS duration >130 ms at baseline have the poorer response after ablation.


Assuntos
Ablação por Cateter , Disfunção Ventricular Esquerda , Complexos Ventriculares Prematuros , Idoso , Eletrocardiografia , Humanos , Masculino , Pessoa de Meia-Idade , Volume Sistólico , Disfunção Ventricular Esquerda/diagnóstico por imagem , Disfunção Ventricular Esquerda/cirurgia , Função Ventricular Esquerda , Complexos Ventriculares Prematuros/diagnóstico , Complexos Ventriculares Prematuros/cirurgia
13.
J Cardiovasc Electrophysiol ; 30(9): 1483-1490, 2019 09.
Artigo em Inglês | MEDLINE | ID: mdl-31115940

RESUMO

INTRODUCTION: Recurrences after atrial fibrillation (AF) ablation are still common. Among the reported clinical and imaging predictors of recurrences, diagnosis-to-ablation time (DAT) has been defined as a predictor of ablation outcome in single-center studies. We aimed to validate DAT in a multicenter real-life cohort. METHODS: This was a multicenter study including consecutive patients undergoing first paroxysmal and persistent AF ablation with radiofrequency or cryoballoon catheters during 2013. Cox proportional hazard regression models were performed to identify predictors of recurrence. RESULTS: In total, 309 patients were included across nine centers (71% men, 57 ± 10 years old, 46% with hypertension, and 66% with CHA2 DS2 -VASc ≤ 1). Most patients had paroxysmal AF (67%) and underwent radiofrequency ablation (68%) with a median DAT of 51 (43) months. Patients with DAT ≤ 1 year (16.6%) were less likely to have repeat procedures (4% vs 18%; P = .017). The adjusted proportional hazards Cox model identified hypertension (P = .005), heart failure (P = .011), nonparoxysmal AF (P = .038), DAT > 1 year (P = .007), and LA diameter (P = .026) as independent predictors for AF recurrence. DAT > 1 year was the only modifiable factor independently associated with recurrence (HR 4.2 [95% CI, 1.5-11.9]) CONCLUSION: Diagnosis-to-ablation time is a modifiable factor independently associated with recurrent arrhythmia and repeat ablation after first AF ablation. An early intervention strategy during the first year from AF diagnosis might improve outcomes.


Assuntos
Fibrilação Atrial/cirurgia , Ablação por Cateter , Criocirurgia , Veias Pulmonares/cirurgia , Tempo para o Tratamento , Potenciais de Ação , Idoso , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/fisiopatologia , Ablação por Cateter/efeitos adversos , Criocirurgia/efeitos adversos , Feminino , Frequência Cardíaca , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Veias Pulmonares/fisiopatologia , Recidiva , Medição de Risco , Fatores de Risco , Espanha , Fatores de Tempo , Resultado do Tratamento
14.
Europace ; 21(7): 1079-1087, 2019 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-30904923

RESUMO

AIMS: Ablation of frequent premature ventricular complexes (PVCs) improves left ventricular ejection fraction in patients with left ventricular (LV) systolic dysfunction. This study aims to evaluate the long-term hard outcomes and potential prognostic variables in this population. METHODS AND RESULTS: Prospective multicentre study including 101 consecutive patients [56 ± 12 years old, 62 (61%) men] with LV systolic dysfunction and frequent PVCs who underwent PVC ablation before November 2015. The last evaluation performed was considered the long-term follow-up (LTFUP) evaluation. Mean follow-up was 34 ± 16 months (range 24-84 months). Ablation was successful in 95 (94%) patients. There was a significant reduction in the PVC burden from 21 ± 12% at baseline to 3.8 ± 6% at LTFUP, P < 0.001. Left ventricular ejection fraction improved from 32 ± 8% at baseline to 39 ± 12% at LTFUP (P < 0.001) and New York Heart Association class from 2.2 ± 0.6% to 1.3 ± 0.6% (P < 0.001). Brain natriuretic peptide levels decreased from 136 (78-321) to 68 (32-144) pg/mL (P = 0.007). Most of this improvement occurs during the first 6 months after ablation. Persistent abolition of at least 18 points of the baseline PVC burden was independently and inversely associated with the composite endpoint of cardiac mortality, cardiac transplantation, or hospitalization for heart failure during follow-up [hazard ratio 0.18 (0.05-0.66), P = 0.01]. CONCLUSION: In patients with LV systolic dysfunction, ablation of frequent PVCs induces a significant improvement in functional, structural, and neurohormonal status, which persists at LTFUP. A sustained reduction in the baseline PVC burden is associated with a lower risk of cardiac mortality, cardiac transplantation, or hospitalization for heart failure during follow-up.


Assuntos
Ablação por Cateter/métodos , Disfunção Ventricular Esquerda/cirurgia , Complexos Ventriculares Prematuros/cirurgia , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Prognóstico , Estudos Prospectivos , Volume Sistólico , Sístole , Disfunção Ventricular Esquerda/mortalidade , Disfunção Ventricular Esquerda/fisiopatologia , Complexos Ventriculares Prematuros/mortalidade , Complexos Ventriculares Prematuros/fisiopatologia
15.
BMC Cardiovasc Disord ; 17(1): 54, 2017 Feb 07.
Artigo em Inglês | MEDLINE | ID: mdl-28173757

RESUMO

BACKGROUND: The AMI code is a regional network enhancing a rapid and widespread access to reperfusion therapy (giving priority to primary angioplasty) in patients with acute ST-segment elevation myocardial infarction (STEMI). We aimed to assess the long-term control of conventional cardiovascular risk factors after a STEMI among patients included in the AMI code registry. DESIGN AND METHODS: Four hundred and fifty-four patients were prospectively included between June-2009 and April-2013. Clinical characteristics were collected at baseline. The long-term control of cardiovascular risk factors and cardiovascular morbidity/mortality was assessed among the 6-months survivors. RESULTS: A total of 423 patients overcame the first 6 months after the STEMI episode, of whom 370 (87%) underwent reperfusion therapy (363, 98% of them, with primary angioplasty). At 1-year follow-up, only 263 (62%) had adequate blood pressure control, 123 (29%) had LDL-cholesterol within targeted levels, 126/210 (60%) smokers had withdrawn from their habit and 40/112 (36%) diabetic patients had adequate glycosylated hemoglobin levels. During a median follow-up of 20 (11-30) months, cumulative mortality of 6 month-survivors was 6.1%, with 9.9% of hospital cardiovascular readmissions. The lack of assessment of LDL and HDL-cholesterol were significantly associated with higher mortality and cardiovascular readmission rates. CONCLUSIONS: Whereas implementation of the AMI code resulted in a widespread access to rapid reperfusion therapy, its long-term therapeutic benefit may be partially counterbalanced by a manifestly suboptimal control of cardiovascular risk factors. Further efforts should be devoted to secondary prevention strategies after STEMI.


Assuntos
Intervenção Coronária Percutânea , Infarto do Miocárdio com Supradesnível do Segmento ST/terapia , Prevenção Secundária/métodos , Idoso , Idoso de 80 Anos ou mais , Anti-Hipertensivos/uso terapêutico , Prestação Integrada de Cuidados de Saúde , Feminino , Humanos , Hipoglicemiantes/uso terapêutico , Hipolipemiantes/uso terapêutico , Masculino , Pessoa de Meia-Idade , Readmissão do Paciente , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/mortalidade , Avaliação de Programas e Projetos de Saúde , Estudos Prospectivos , Recidiva , Sistema de Registros , Medição de Risco , Fatores de Risco , Comportamento de Redução do Risco , Infarto do Miocárdio com Supradesnível do Segmento ST/diagnóstico , Infarto do Miocárdio com Supradesnível do Segmento ST/mortalidade , Infarto do Miocárdio com Supradesnível do Segmento ST/fisiopatologia , Fumar/efeitos adversos , Abandono do Hábito de Fumar , Prevenção do Hábito de Fumar , Fatores de Tempo , Resultado do Tratamento
16.
J Cardiovasc Electrophysiol ; 27(6): 694-8, 2016 06.
Artigo em Inglês | MEDLINE | ID: mdl-26915806

RESUMO

INTRODUCTION: The incremental pacing (IP) maneuver is a highly specific technique that improves the ability to confirm complete CTI conduction block during typical atrial flutter (AFL) ablation, and reduces long-term AFL recurrences. The purpose of this study is to assess the performance of new catheters equipped with additional high precision bipoles (AHPB) to allow the visualization of the cavotricuspid isthmus (CTI) conduction gap and to compare them with the IP maneuver. METHODS AND RESULTS: Twenty consecutive patients undergoing catheter ablation of the CTI for AFL were included. The IP maneuver confirmed functional versus complete CTI block. Local electrogram analysis using AHPB was then used to assess the presence or absence of gaps across the CTI line. Mean age was 67 years and 80% were male. At the end of the procedure CTI block was achieved in all patients. A transient stage of functional CTI block was observed in 40%. In all cases a continuous fragmented electrogram was present between the double potentials in the CTI in the AHPB channels. In contrast, no electrogram was observed between the CTI double potentials in any of the 20 patients once complete block was confirmed by the IP maneuver. When both techniques were compared a significant association and correlation were observed (chi-square <0.01, Spearman's rho = 1, P < 0.01). CONCLUSION: Catheters equipped with AHPB can aid in the assessment of complete CTI block during AFL ablation procedures by detecting conduction gaps that correlate with incomplete functional block diagnosed by the IP maneuver.


Assuntos
Flutter Atrial/cirurgia , Cateteres Cardíacos , Estimulação Cardíaca Artificial , Ablação por Cateter , Técnicas Eletrofisiológicas Cardíacas/instrumentação , Marca-Passo Artificial , Valva Tricúspide/cirurgia , Potenciais de Ação , Idoso , Flutter Atrial/diagnóstico , Flutter Atrial/fisiopatologia , Ablação por Cateter/efeitos adversos , Desenho de Equipamento , Feminino , Frequência Cardíaca , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Recidiva , Resultado do Tratamento , Valva Tricúspide/fisiopatologia
20.
Heart Rhythm ; 20(9): 1279-1286, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37329936

RESUMO

BACKGROUND: Cardioneuroablation (CNA) is a novel treatment for reflex syncope. The effect of aging on CNA efficacy is not fully understood. OBJECTIVE: The purpose of this study was to assess the impact of aging on candidacy and efficacy of CNA for treating vasovagal syncope (VVS), carotid sinus syndrome (CSS), and functional bradyarrhythmia. METHODS: The ELEGANCE (cardionEuroabLation: patiEnt selection, imaGe integrAtioN and outComEs) multicenter study assessed CNA in patients with reflex syncope or severe functional bradyarrhythmia. Patients underwent pre-CNA Holter electrocardiography (ECG), head-up tilt testing (HUT), and electrophysiological study. CNA candidacy and efficacy was assessed in 14 young (18-40 years), 26 middle-aged (41-60 years), and 20 older (>60 years) patients. RESULTS: Sixty patients (37 men; mean age 51 ± 16 years) underwent CNA. The majority (80%) had VVS, 8% had CSS, and 12% had functional bradycardia/atrioventricular block. Pre-CNA Holter ECG, HUT, and electrophysiological findings did not differ across age groups. Acute CNA success was 93%, without differences between age groups (P = .42). Post-CNA HUT response was negative in 53%, vasodepressor in 38%, cardioinhibitory in 7%, and mixed in 2%, without differences across age groups (P = .59). At follow-up (8 months, interquartile range 4-15), 53 patients (88%) were free of symptoms. Kaplan-Meier curves did not show differences in event-free survival between age groups (P = .29). The negative predictive value of a negative HUT was 91.7%. CONCLUSION: CNA is a viable treatment for reflex syncope and functional bradyarrhythmia in all ages, and is highly effective in mixed VVS. HUT is a key step in postablation clinical assessment.


Assuntos
Síncope Vasovagal , Masculino , Pessoa de Meia-Idade , Humanos , Adulto , Idoso , Síncope Vasovagal/diagnóstico , Síncope Vasovagal/cirurgia , Bradicardia/diagnóstico , Bradicardia/cirurgia , Seleção de Pacientes , Síncope/diagnóstico , Teste da Mesa Inclinada/métodos , Envelhecimento , Reflexo
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa