1.
Orthopade ; 47(1): 39-51, 2018 Jan.
Artigo em Alemão | MEDLINE | ID: mdl-29238859

RESUMO

BACKGROUND: The reconstruction of bony defects during endoprosthesis revision surgery using "impaction bone grafting" leads to the possibility of a longstanding osseous integration to achieve good clinical results. Native allogeneic cancellous bone is often used for the procedure. This study examines the influence of thermodisinfection on the impaction behaviour of cancellous bone of different geometries and on the cement distribution. METHODS: The cancellous bone was obtained from the femoral heads of 7­month old pigs. One half of the head was thermodisinfected while the other remained native. Bone chips with sizes of 3-5, 5-8 and 8-10 mm were produced. The impaction was performed in a cylinder model with an internal diameter of 30 mm and with standardized impaction force using an impactor with a weight of 1450 g. The best particle combination was used for the subsequent computer tomography examination of the cement distribution and the contact surface to the bone in different parts of the shaft in seven investigations. For statistic measurements two-dimensional variance analysis including repetitions of measurement and Bonferroni correction, the LSD post-hoc-zest and the Mann Whitney U Test were used. The error probability was set at α = 5%. The SPSS® for Windows software was used for the statistical analysis. RESULTS: The distribution of the cancellous and compacted bone also along the shaft revealed no significant difference between thermodisinfected and native cancellous bone at different levels (p > 0.05). Impacted native cancellous bone showed less inclusion of air, which resulted in a better distribution of density compared with thermodisinfected bone overall (p < 0.001). In the distal shaft area the cement volume was significantly larger in conjunction with the native bone. The overall area of cement penetration appeared to be significantly larger for native cancellous bone (p < 0.001). CONCLUSIONS: The impaction of thermodisinfected and native cancellous bone showed greater deformation of the processed bone without any significant difference in the maximum density reached at different levels. Cement volume and cement penetration were pronounced proximally in native and processed cancellous bone. The cement distribution was significantly more distal for the native bone. Distally, the stabilization of the shaft appears to be increasingly dependent on the density of the impacted spongiosa, while proximally, the penetration of the cement into cancellous bone seems to correlate with porosity.


Assuntos
Antibacterianos/administração & dosagem , Transplante Ósseo/métodos , Portadores de Fármacos , Procedimentos Ortopédicos/métodos , Osteomielite/tratamento farmacológico , Procedimentos de Cirurgia Plástica/métodos , Antibacterianos/efeitos adversos , Transplante Ósseo/efeitos adversos , Portadores de Fármacos/efeitos adversos , Seguimentos , Infecções Relacionadas à Prótese/cirurgia , Reoperação
2.
Rofo ; 188(2): 146-54, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-26815120

RESUMO

UNLABELLED: Nano-computed tomography (nano-CT) is an emerging, high-resolution cross-sectional imaging technique and represents a technical advancement of the established micro-CT technology. Based on the application of a transmission target X-ray tube, the focal spot size can be decreased down to diameters less than 400 nanometers (nm). Together with specific detectors and examination protocols, a superior spatial resolution up to 400 nm (10 % MTF) can be achieved, thereby exceeding the resolution capacity of typical micro-CT systems. The technical concept of nano-CT imaging as well as the basics of specimen preparation are demonstrated exemplarily. Characteristics of atherosclerotic plaques (intraplaque hemorrhage and calcifications) in a murine model of atherosclerosis (ApoE (-/-)/LDLR(-/-) double knockout mouse) are demonstrated in the context of superior spatial resolution in comparison to micro-CT. Furthermore, this article presents the application of nano-CT for imaging cerebral microcirculation (murine), lung structures (porcine), and trabecular microstructure (ovine) in contrast to micro-CT imaging. This review shows the potential of nano-CT as a radiological method in biomedical basic research and discusses the application of experimental, high resolution CT techniques in consideration of other high resolution cross-sectional imaging techniques. KEY POINTS: Nano-computed tomography is a high resolution CT-technology for 3D imaging at sub-micrometer resolution. The technical concept bases on a further development of the established ex-vivo-micro-CT technology. By improvement of the spatial resolution, structures at a cellular level become visible (e.g. osteocyte lacunae).


Assuntos
Imageamento Tridimensional/instrumentação , Imageamento Tridimensional/métodos , Nanotecnologia/instrumentação , Nanotecnologia/métodos , Tomografia Computadorizada por Raios X/instrumentação , Tomografia Computadorizada por Raios X/métodos , Microtomografia por Raio-X/instrumentação , Microtomografia por Raio-X/métodos , Animais , Aterosclerose/patologia , Pesquisa Biomédica , Encéfalo/irrigação sanguínea , Modelos Animais de Doenças , Humanos , Pulmão/patologia , Microcirculação/fisiologia , Osteócitos/patologia , Osteoporose/patologia , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa