Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 42
Filtrar
1.
J Cardiovasc Electrophysiol ; 34(3): 728-737, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-36477909

RESUMO

INTRODUCTION: Lead dwell time >10 years is a recognized predictor for transvenous lead extraction (TLE) failure and complications. Data on the efficacy and safety of TLE using the bidirectional rotational mechanical sheaths in patients with very old leads are lacking. In this multicenter study, we reported the outcomes of transvenous rotational mechanical lead extraction in patients with leads implanted for ≥10 years. METHODS: A total of 441 leads (median: 159 months [135-197]; range: 120-487) in 189 consecutive patients were removed with the Evolution RL sheaths (Cook Medical, Bloomingtom, IN, USA) and mechanical ancillary tools supporting the procedures. RESULTS: The main indication for TLE was infection in 74% of cases. Complete procedural success rate, clinical success rate, per lead were 94.8% and 98.2%, respectively. Failure of lead extraction was seen in 1.8% of leads. The additional use of a snare via the femoral approach was required in 9% of patients. Lead dwell time was the only predictor of incomplete led removal (odds ratio: 1.009; 95% confidence interval [CI]: 1.003-1.014; p = .002). Four major complication (2%) were encountered. During a mean time follow-up of 31 ± 27 months, 21 patients (11%) died. No procedure-related mortality occurred. Predictors of mortality included severe left ventricular systolic dysfunction (hazard ratio [HR]: 8.06; 95% CI: 2.99-21.73; p = .001), TLE for infection (HR: 8.0; 95% CI: 1.04-62.5; p = .045), diabetes (HR: 3.7; 95% CI: 1.48-9.5; p = .005), and previous systemic infection (HR: 3.1; 95% CI: 1.17-8.24; p = .022). Incomplete lead removal or failure lead extraction did not impact on survival during follow-up. CONCLUSION: Our findings demonstrated that the use of bidirectional rotational TLE mechanical sheaths combined with different mechanical tools and femoral approach allows reasonable success and safety in patients with very old leads at experienced specialized centers.


Assuntos
Desfibriladores Implantáveis , Marca-Passo Artificial , Humanos , Remoção de Dispositivo/métodos , Eletrodos Implantados , Estudos Retrospectivos , Resultado do Tratamento
2.
Pacing Clin Electrophysiol ; 45(6): 752-760, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-35403246

RESUMO

BACKGROUND: Little is known regarding the characterization of electrical substrate in both atria in patients with atrial fibrillation (AF). METHODS: Eight consecutive patients undergoing AF ablation (five paroxysmal, three persistent) underwent electrical substrate characterization during sinus rhythm. Mapping of the left (LA) and right atrium (RA) was performed with the use of the HD Grid catheter (Abbott). Bipolar voltage maps were analyzed to search for low voltage areas (LVA), the following electrophysiological phenomena were assessed: (1) slow conduction corridors, and (2) lines of block. EGMs were characterized to search for fractionation. Electrical characteristics were compared between atria and between paroxysmal versus persistent AF patients. RESULTS: In the RA, LVAs were present in 60% of patients with paroxysmal AF and 100% of patients with persistent AF. In the LA, LVAs were present in 40% of patients with paroxysmal AF and 66% of patients with persistent AF. The areas of LVA in the RA and LA were 4.8±7.3 cm2 and 7.8±13.6 cm2 in patients with paroxysmal AF versus 11.7±3.0 cm2 and 2.1±1.8 cm2 in patients with persistent AF. In the RA, slow conduction corridors were present in 40.0% (paroxysmal AF) versus 66.7% (persistent AF) whereas in the LA, slow conduction corridors occurred in 20.0% versus 33.3% respectively (p = ns). EGM analysis showed more fractionation in persistent AF patients than paroxysmal (RA: persistent AF 10.8 vs. paroxysmal AF 4.7%, p = .036, LA: 10.3 vs. 4.1%, p = .108). CONCLUSION: Bi-atrial involvement is present in patients with paroxysmal and persistent AF. This is expressed by low voltage areas and slow conduction corridors whose extension progresses as the arrhythmia becomes persistent. This electrophysiological substrate demonstrates the important interplay with the pulmonary vein triggers to constitute the substrate for persistent arrhythmia.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Fibrilação Atrial/cirurgia , Técnicas Eletrofisiológicas Cardíacas , Átrios do Coração , Humanos , Veias Pulmonares/cirurgia
3.
Pacing Clin Electrophysiol ; 45(5): 658-665, 2022 05.
Artigo em Inglês | MEDLINE | ID: mdl-35417049

RESUMO

BACKGROUND: With an increasing number of cardiac implantable electronic devices (CIEDs), there has been a paralleled increase in demand for transvenous lead extraction (TLE). Cardiac surgeons (CS) and cardiologists perform TLE; however, data comparing the two groups of operators is scarce. OBJECTIVE: We compared the outcomes of TLE performed by cardiologists and CS from six European lead extraction units. METHOD: Data was collected retrospectively of 2205 patients who had 3849 leads extracted (PROMET) between 2005 and 2018. Patient demographics and procedural outcomes were compared between the CS and cardiologist groups, using propensity score matching. A multivariate regression analysis was also performed for variables associated with 30-day mortality. RESULTS: CS performed the majority of extractions (59.8%), of leads with longer dwell times (90 [57-129 interquartile range (IQR)] vs. 62 [31-102 IQR] months, CS vs. cardiologists, p < .001) and with pre-dominantly non-infectious indications (57.4% vs. 50.2%, CS vs. cardiologists, p < .001). CS achieved a higher complete success per lead than the cardiologists (98.1% vs. 95.7%, respectively, p < .01), with a higher number of minor complications (5.51% vs. 2.1%, p < .01) and similar number of major complications (0.47% vs. 1.3%, p = .12). Thirty-day mortality was similarly low in the CS and cardiologist groups (1.76% vs. 0.94%, p = .21). Unmatched data multivariate analysis revealed infection indication (OR 6.12 [1.9-20.3], p < .01), procedure duration (OR 1.01 [1.01-1.02], p < .01) and CS operator (OR 2.67, [1.12-6.37], p = .027) were associated with 30-day mortality. CONCLUSION: TLE by CS was performed with similar safety and higher efficacy compared to cardiologists in high and medium-volume lead extraction centers.


Assuntos
Desfibriladores Implantáveis , Marca-Passo Artificial , Remoção de Dispositivo/métodos , Humanos , Prometazina , Estudos Retrospectivos , Resultado do Tratamento
4.
Pacing Clin Electrophysiol ; 45(1): 23-34, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-34841552

RESUMO

BACKGROUND: Left atrial appendage (LAA) thrombosis increases the risk of stroke and its management has to be assessed. The aim of the present study is to evaluate short and long-term safety and efficacy of a standardized approach of percutaneous LAA closure (LAAC) routinely using a cerebral protection device (CPD) in patients with LAA thrombosis or sludge (LAAT). METHODS: We prospectively enrolled 14 consecutive patients with atrial fibrillation complicated by LAAT presenting in a high-volume tertiary center. In seven patients (50%) LAAT was found after anticoagulant withdrawal for severe bleedings and in the remaining half LAAT was found despite appropriate anticoagulant therapy. All patients were treated with a standardized interventional approach of LAAC routinely using a CPD and guided by transoesophageal echocardiography. RESULTS: Mean age was 68 ± 14 years and nine patients (64%) were male. Mean CHA2 DS2 -VASc and HAS-BLED scores were 3.3 ± 1.6 and 2.3 ± 1.1, respectively. Six patients (42.8%) presented organized thrombi while eight LAA sludge (57.1%). In 13 patients (92.8%) CPD was positioned through a right radial arterial access. Procedural success was achieved in all patients. In one patient we assisted to embolization of the thrombus during deployment of the device in the absence of neurological consequences. During a mean follow up of 426 ± 307 days, one patient died for non-cardiac cause while no embolic event or major bleeding were reported. CONCLUSION: In an unselected cohort, LAAC with the systematic use of CPD was a feasible, safe and effective therapeutic option for LAAT both acutely and after long-term follow-up.


Assuntos
Apêndice Atrial/cirurgia , Fibrilação Atrial/cirurgia , Procedimentos Cirúrgicos Cardíacos , Dispositivos de Proteção Embólica , Acidente Vascular Cerebral/prevenção & controle , Trombose/cirurgia , Idoso , Ecocardiografia Transesofagiana , Feminino , Humanos , Masculino , Estudos Prospectivos , Dispositivo para Oclusão Septal
5.
Pacing Clin Electrophysiol ; 44(9): 1540-1548, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-34235772

RESUMO

BACKGROUND: Cardiac implantable electronic device (CIED) therapy contributes to an improvement in morbidity and mortality across all patient demographics. Patient age is a recognized risk factor for unfavorable outcomes in invasive procedures. This is the largest series of non-laser transvenous lead extraction (TLE) evaluating the association between patient age and procedure outcomes. METHODS: Data of 2205 (3849 leads) patients was collected retrospectively from six European TLE centers between January 2005-December 2018 in the PROMET study. Of these, 153 patients with 319 leads were excluded for incomplete data. A comparison of outcomes was performed between the age groups young [< 50 years], young intermediate [50-69 years], older intermediate [70-79 years], and octogenarian [≥80 years]. RESULTS: Infection was most common indication for TLE in the octogenarian cohort, less common in the younger population (60.1% vs. 33.2%, respectively, p < .01). High-voltage leads were extracted most frequently from young patients, less frequently from octogenarians (31.6% vs. 10%, p < .001), while the opposite was evident for pacemaker leads (p < .001). Rotational sheath use was equally prevalent across all patient groups (p = .79). Minor and major complications across all the age groups were statistically similar, as was procedural success; the 30-day mortality was most significant in the octogenarian and least in the young patients (4.9% vs. 0.4%, p = .005). Propensity matching multivariate analysis found systemic infection, lead dwell time, and patient age (p = .013, OR 1.064 [1.013-1.116]) increased risk of 30-day mortality. CONCLUSION: TLE is safe and effective across all age groups. 30-day mortality risk is significantly higher in the older patients.


Assuntos
Remoção de Dispositivo/métodos , Eletrodos Implantados , Adulto , Fatores Etários , Idoso , Idoso de 80 Anos ou mais , Europa (Continente) , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos
6.
Europace ; 22(4): 613-621, 2020 04 01.
Artigo em Inglês | MEDLINE | ID: mdl-32087025

RESUMO

AIMS: A validated risk stratification schema for transvenous lead extraction (TLE) could improve the management of these procedures. We aimed to derive and validate a scoring system to efficiently predict the need for advanced tools to achieve TLE success. METHODS AND RESULTS: Between November 2013 and March 2018, 1960 leads were extracted in 973 consecutive TLE procedures in two national referral sites using a stepwise approach. A procedure was defined as advanced extraction if required the use of powered sheaths and/or snares. The study population was a posteriori 1:1 randomized in derivation and validation cohorts. In the derivation cohort, presence of more than two targeted leads (odds ratio [OR] 1.76, P = 0.049), 3-year-old (OR 3.04, P = 0.001), 5-year-old (OR 3.48, P < 0.001), 10-year-old (OR 3.58, P = 0.008) oldest lead, implantable cardioverter-defibrillator (OR 3.84, P < 0.001), and passive fixation lead (OR 1.91, P = 0.032) were selected by a stepwise procedure and constituted the MB score showing a C-statistics of 0.82. In the validation group, the MB score was significantly associated with the risk of advanced extraction (OR 2.40, 95% confidence interval 2.02-2.86, P < 0.001) and showed an increase in event rate with increasing score. A low value (threshold = 1) ensured 100% sensibility and 100% negative predictive value, while a high value (threshold = 5) allowed a specificity of 92.8% and a positive predictive value of 91.9%. CONCLUSION: In this study, we developed and tested a simple point-based scoring system able to efficiently identify patients at low and high risk of needing advanced tools during TLE procedures.


Assuntos
Desfibriladores Implantáveis , Marca-Passo Artificial , Criança , Pré-Escolar , Remoção de Dispositivo , Falha de Equipamento , Humanos , Estudos Retrospectivos , Medição de Risco
7.
Europace ; 22(7): 1103-1110, 2020 07 01.
Artigo em Inglês | MEDLINE | ID: mdl-32447388

RESUMO

AIMS: Several large studies have documented the outcome of transvenous lead extraction (TLE), focusing on laser and mechanical methods. To date there has been no large series addressing the results obtained with rotational lead extraction tools. This retrospective multicentre study was designed to investigate the outcomes of mechanical and rotational techniques. METHODS AND RESULTS: Data were collected on a total of 2205 patients (age 66.0 ± 15.7 years) with 3849 leads targeted for extraction in six European lead extraction centres. The commonest indication was infection (46%). The targeted leads included 2879 pacemaker leads (74.8%), 949 implantable cardioverter-defibrillator leads (24.6%), and 21 leads for which details were unknown; 46.6% of leads were passive fixation leads. The median lead dwell time was 74 months [interquartile range (IQR) 41-112]. Clinical success was obtained in 97.0% of procedures, and complete extraction was achieved for 96.5% of leads. Major complications occurred in 22/2205 procedures (1%), with a peri-operative or procedure-related mortality rate of 4/2205 (0.18%). Minor complications occurred in 3.1% of procedures. A total of 1552 leads (in 992 patients) with a median dwell time of 106 months (IQR 66-145) were extracted using the Evolution rotational TLE tool. In this subgroup, complete success was obtained for 95.2% of leads with a procedural mortality rate of 0.4%. CONCLUSION: Patient outcomes in the PROMET study compare favourably with other large TLE trials, underlining the capability of rotational TLE tools and techniques to match laser methods in efficacy and surpass them in safety.


Assuntos
Desfibriladores Implantáveis , Marca-Passo Artificial , Idoso , Idoso de 80 Anos ou mais , Desfibriladores Implantáveis/efeitos adversos , Remoção de Dispositivo , Humanos , Pessoa de Meia-Idade , Estudos Retrospectivos , Resultado do Tratamento
8.
Pacing Clin Electrophysiol ; 42(7): 989-997, 2019 07.
Artigo em Inglês | MEDLINE | ID: mdl-30997679

RESUMO

BACKGROUND: In addition to the Evolution RL sheath, tools by Cook Medical (Bloomington, IN, USA), supporting lead extraction (LE), are available. Data on their use are not reported in detail in previous studies. Moreover, data regarding outcome are lacking. The aim was to evaluate the safety and effectiveness of the Evolution sheath (Evolution RL and Evolution Shortie, Cook Medical) by using a stepwise approach with the available extraction tools and the outcome. METHODS: A total of 393 leads in 198 consecutive patients were removed with the Evolution RL sheath and ancillary tools using a stepwise approach. RESULTS: The main indication for LE was infection in 125 (63.1%) cases. The mean implant duration was 95.4 ± 59.7 months. According to our stepwise approach, the Evolution Shortie RL sheath was used in all cases and complete LE was achieved in 24 (12.2%) cases. The Evolution RL was used in 174 (87.8%) cases and the SteadySheath Evolution tissue stabilization sheath (Cook Medical) in 87 (44%) because of tenacious fibrosis anchored targeted leads. Compression coil (OneTie, Cook Medical) was used in 141 (71%) cases. Complete procedural success rate, clinical success rate, and lead removal with clinical success rate were 97%, 99%, and 99.5%, respectively. One major complication (0.5%) and 10 (5%) minor complications were encountered. During a mean time follow-up of 12 ± 9 months, 14 (7%) patients died. Predictors of mortality included impaired renal function (HR 5.7; 95% CI 1.9-17.6; P = 0.002), extraction because of infection (hazard ratio [HR] 4.0; 95% confidence interval [CI] 1-18.1; P = 0.045), and diabetes (HR 3.2; 95% CI 1.1-9.8; P = 0.036). CONCLUSIONS: Lead extraction using the Evolution RL bidirectional rotational mechanical sheath and ancillary tools in a systematic stepwise approach was effective and safe.


Assuntos
Remoção de Dispositivo/instrumentação , Eletrodos Implantados , Marca-Passo Artificial , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Criança , Ecocardiografia Transesofagiana , Desenho de Equipamento , História do Século XVII , Humanos , Segurança do Paciente , Fatores de Risco , Ultrassonografia de Intervenção
9.
J Cardiovasc Electrophysiol ; 29(8): 1119-1124, 2018 08.
Artigo em Inglês | MEDLINE | ID: mdl-29543365

RESUMO

INTRODUCTION: Late potentials (LP) abolition is recognized as an effective strategy for substrate ablation of ventricular tachycardia (VT). The presence of a chronic total occlusion in a coronary artery responsible for a previous myocardial infarction (infarct related artery CTO, IRA-CTO) is emerging as a predictor of ventricular arrhythmias and VT recurrence after ablation. We sought to analyze the effects of LP abolition, focusing on the high-risk subgroup of patients with IRA-CTO. METHODS AND RESULTS: This was a single-center, observational study that screened all patients with prior myocardial infarction and clinical VT, referred for VT ablation at San Raffaele Hospital between 2010 and June 2013. Patients were then included in the study if they had a coronary diagnostic angiography (without revascularization) performed during the index hospitalization. The main endpoint was VT recurrence after ablation. Eighty-four patients formed the population of the study. An IRA-CTO was present in 47 patients (56%) and the presence of an IRA-CTO was a predictor of VT recurrence (HR 3.7, P = 0.005). LP were observed in 51 patients and successfully abolished in 38 cases. LP abolition was associated with lower VT recurrence especially among patients with IRA-CTO (24% vs. 65%, P = 0.005). The presence of an IRA-CTO, in combination with no LP abolition, was the strongest predictor of VT recurrence (HR 4.4, P < 0.001). CONCLUSIONS: Late potentials abolition is an effective strategy for substrate ablation of ventricular tachycardia. The additional reduction of VT recurrence achieved with LP abolition on top of noninducibility is especially significant among high-risk patients with IRA-CTO.


Assuntos
Ablação por Cateter/tendências , Oclusão Coronária/cirurgia , Eletrocardiografia/tendências , Infarto do Miocárdio/cirurgia , Taquicardia Ventricular/cirurgia , Idoso , Oclusão Coronária/fisiopatologia , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/fisiopatologia , Estudos Prospectivos , Fatores de Risco , Taquicardia Ventricular/fisiopatologia , Resultado do Tratamento
10.
Europace ; 20(5): 829-834, 2018 05 01.
Artigo em Inglês | MEDLINE | ID: mdl-28339758

RESUMO

Aims: The aim of this prospective multicentre study is to evaluate safety and efficacy of the new bidirectional rotational mechanical lead extraction (LE) sheath (Evolution RL, Cook Medical, USA) in chronically implanted leads (>1-year-old leads). Methods and results: Between September 2013 and June 2016, a total of 238 leads in 124 consecutive patients were removed by using the new Evolution RL rotational mechanical sheath. Indications for LE were cardiac device infection in 63 (50.8%) cases, lead malfunction in 41 (33.1%), upgrade in 1 (0.8%) case and for other reasons in the remaining 19 cases (15.3%). Ninety-one leads (38.2%) were implantable cardioverter defibrillator leads (81 dual coil vs. 10 single coil), 38 (16%) right ventricular leads, 86 (36.1%) right atrial leads, and 23 (9.7%) coronary sinus leads. The mean implant duration was 92.2 ± 52.9 months (range 12-336). 91.6% of the leads (218/238) were extracted completely with the Evolution RL alone, with the complete success rate rising to 98.7% (235/238 leads) with combined use of a snare. Overall clinical success rate was 100%. No Evolution sheath-related complications were noted. There were no deaths or major complications. Five minor complications (4%) were encountered. In cases of companion leads no wrapping or lead damage were observed. Conclusion: On the basis of our prospective multicentre study, the new hand-powered bidirectional rotational mechanical LE sheath is an effective and safe tool for the extraction of chronically implanted leads without major complications and lead wrapping or lead damage.


Assuntos
Desfibriladores Implantáveis/efeitos adversos , Remoção de Dispositivo , Marca-Passo Artificial/efeitos adversos , Infecções Relacionadas à Prótese/cirurgia , Idoso , Remoção de Dispositivo/efeitos adversos , Remoção de Dispositivo/instrumentação , Remoção de Dispositivo/métodos , Feminino , Humanos , Itália , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Sistema de Registros/estatística & dados numéricos , Resultado do Tratamento
11.
Catheter Cardiovasc Interv ; 89(4): 763-772, 2017 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-27567013

RESUMO

OBJECTIVES: To compare indications and clinical outcomes of two contemporary left atrial appendage (LAA) percutaneous closure systems in a "real-world" population. BACKGROUND: Percutaneous LAA occlusion is an emerging therapeutic option for stroke prevention in atrial fibrillation. Some questions however remain unanswered, such as the applicability of results of randomized trials to current clinical practice. Moreover, currently available devices have never been directly compared. METHODS: We retrospectively analyzed consecutive patients who underwent LAA closure at San Raffaele Hospital, Milan, Italy between 2009 and 2015. Clinical indications and device selection were left to operators' decision; routine clinical and transesophageal echocardiography (TEE) follow-up was performed. RESULTS: One-hundred and sixty-five patients were included in the study, of which 99 were treated with the Amplatzer Cardiac Plug (ACP) and 66 with the Watchman system. During the follow-up period (median 15 months, interquartile range 6-26 months) five patients died. The incidence of ischemic events was low, with one patient suffering a transient ischemic attack and no episodes recorded of definitive strokes. Twenty-six leaks ≥1 mm were detected (23%); leaks were less common with the ACP and with periprocedural three-dimensional TEE evaluation, but were not found to correlate with clinical events. Clinical outcomes were comparable between the two devices. CONCLUSIONS: Our data show excellent safety and efficacy of LAA closure, irrespectively of the device utilized, in a population at high ischemic and hemorrhagic risk. The use of ACP and 3D-TEE minimized the incidence of residual leaks; however, the clinical relevance of small peri-device flow warrants further investigation. © 2016 Wiley Periodicals, Inc.


Assuntos
Apêndice Atrial/cirurgia , Fibrilação Atrial/cirurgia , Cateterismo Cardíaco/métodos , Procedimentos Cirúrgicos Cardíacos/métodos , Dispositivo para Oclusão Septal , Acidente Vascular Cerebral/prevenção & controle , Cirurgia Assistida por Computador/métodos , Idoso , Apêndice Atrial/diagnóstico por imagem , Fibrilação Atrial/complicações , Fibrilação Atrial/diagnóstico , Ecocardiografia Doppler em Cores , Ecocardiografia Tridimensional , Ecocardiografia Transesofagiana , Feminino , Seguimentos , Humanos , Incidência , Itália/epidemiologia , Masculino , Desenho de Prótese , Estudos Retrospectivos , Acidente Vascular Cerebral/epidemiologia , Acidente Vascular Cerebral/etiologia , Fatores de Tempo , Resultado do Tratamento
12.
J Cardiovasc Electrophysiol ; 26(5): 532-9, 2015 May.
Artigo em Inglês | MEDLINE | ID: mdl-25598359

RESUMO

INTRODUCTION: In patients with a prior myocardial infarction (MI), angiographic predictors of ventricular tachycardia (VT) recurrence after ablation are lacking. Recently, a proarrhythmic effect of a chronic total occlusion (CTO) in a coronary artery has been suggested. METHODS AND RESULTS: A total of 191 patients with prior MI were referred to our Hospital between 2010 and June 2013 for a first ablation of VT. Of these, 84 patients (44%) with stable coronary artery disease that underwent a coronary angiography during the index hospitalization were included in this study. A CTO in an infarct-related artery (IRA-CTO) was present in 47 patients (56%). Patients with and without IRA-CTO did not differ in terms of comorbidities, severity of heart failure, presentation of VT or acute outcome of ablation, that was completely successful in 93% of cases. At electroanatomic mapping, IRA-CTO was associated with greater scar and especially with greater area of border zone (34 cm(2) vs. 19 cm(2) , P = 0.001). Median follow-up was 19 months (IQR 18). At follow-up, patients with IRA-CTO had a significantly higher rate of VT recurrence (47% vs. 16%, P = 0.003). At multivariate analysis, IRA-CTO resulted to be an independent predictor of VT recurrence after ablation (HR 4.05, P = 0.004). CONCLUSIONS: IRA-CTO is an independent predictor of VT recurrence after ablation and identifies a subgroup of patients with high recurrence rate despite a successful procedure. IRA-CTO is associated with greater scars and border zone area; however, this association does not completely justify its proarrhythmic effect.


Assuntos
Ablação por Cateter , Oclusão Coronária/complicações , Infarto do Miocárdio/etiologia , Taquicardia Ventricular/cirurgia , Idoso , Ablação por Cateter/efeitos adversos , Ablação por Cateter/mortalidade , Doença Crônica , Comorbidade , Angiografia Coronária , Oclusão Coronária/diagnóstico , Oclusão Coronária/mortalidade , Técnicas Eletrofisiológicas Cardíacas , Feminino , Mortalidade Hospitalar , Humanos , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/diagnóstico , Infarto do Miocárdio/mortalidade , Modelos de Riscos Proporcionais , Estudos Prospectivos , Recidiva , Estudos Retrospectivos , Fatores de Risco , Espanha , Taquicardia Ventricular/complicações , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/mortalidade , Fatores de Tempo , Resultado do Tratamento
13.
Can J Cardiol ; 2024 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-38492735

RESUMO

BACKGROUND: In patients with atrial fibrillation (AF) on vitamin K antagonist (VKA) therapy and therapeutic international normalized ratio (INR) range, the incidence of cardiac thromboembolism is not negligible, and the subgroup of patients who have a mechanical prosthetic mitral valve (PMV) has the highest risk. We aimed to assess the long-term effects of left atrial appendage closure (LAAC) in AF patients with a mechanical PMV who experienced a failure of VKA therapy. METHODS: In this retrospective, multicentre study, patients underwent LAAC because of thrombotic events including transient ischemic attack and/or stroke, systemic embolism, and evidence of left atrial appendage thrombosis and/or sludge, despite VKA therapy, were enrolled. Patients with a mechanical PMV were included and compared with those affected by nonvalvular AF. The primary endpoint was the composite of all-cause death, major cardiovascular events, and major bleedings at follow-up. The feasibility and safety of LAAC also were assessed. RESULTS: A total of 55 patients (42% female; mean age, 70 ± 9 years), including 12 with a mechanical PMV, were enrolled. The most-frequent indication to LAAC (71%) was LAA thrombosis or sludge. Procedural success was achieved in 96% of overall cases, and in 100% of patients with a PMV. In 35 patients, a cerebral protection device was used. During a median follow-up of 6.1 ± 4.3 years, 4 patients with a PMV, and 20 patients without a PMV, reported adverse events (hazard ratio 0.73 [95% confidence interval 0.25-2.16, P = 0.564]). CONCLUSIONS: LAAC seems to be a valuable alternative in patients with AF who have a mechanical PMV, with failure of VKA therapy. This off-label, real-world clinical practice indication deserves validation in further studies.

14.
Europace ; 15(12): 1771-6, 2013 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-23645529

RESUMO

AIM: The evolution mechanical dilator sheath has been reported to be an effective tool for chronic lead extraction (LE). We examined safety and efficacy of evolution system as compared with laser system. METHODS AND RESULTS: From 2005 to 2009, all extractions requiring the use of a powered sheath were performed using the excimer laser system (n = 73). Since 2009, laser system was no longer available and the evolution system was introduced as the first-line method for powered extraction (n = 48). All procedures were performed by a single first operator. Success and complications were defined according to the current guidelines. Patients of the evolution group compared with those of the laser group had a greater number of extracted leads per patient (2.77 vs. 2.4, P = 0.049) and a longer implant duration (101.1 vs. 62.4 months, P = 0.001). Additional use of snare was required in 27.1% of the evolution group and 8.2% of the laser group (P = 0.005). Complete procedural success was achieved in 91.7% of the evolution group and 97.3% of the laser group (P = 0.16). There was also no difference between evolution and laser groups in clinical success (97.9 vs. 98.6%, P = 0.76), as well as regarding major (4.2 vs. 2.7%, P = 0.66) or minor complications (4.2 vs. 5.5%, P = 0.76). CONCLUSION: Use of the recently introduced evolution system for LE exhibit acceptably high levels of safety, as well as of procedural and clinical success, although additional use of snare was required more frequently in the evolution compared with the laser group.


Assuntos
Desfibriladores Implantáveis , Remoção de Dispositivo/métodos , Dilatação , Terapia a Laser , Marca-Passo Artificial , Idoso , Cateteres Cardíacos , Remoção de Dispositivo/efeitos adversos , Remoção de Dispositivo/instrumentação , Dilatação/efeitos adversos , Dilatação/instrumentação , Desenho de Equipamento , Feminino , Humanos , Terapia a Laser/efeitos adversos , Terapia a Laser/instrumentação , Lasers de Excimer , Masculino , Pessoa de Meia-Idade , Radiografia Intervencionista , Estudos Retrospectivos , Fatores de Tempo , Resultado do Tratamento
15.
Pacing Clin Electrophysiol ; 36(7): 837-44, 2013 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-23510021

RESUMO

BACKGROUND: Lead extraction (LE) techniques have evolved from simple traction to extraction with dilators and powered sheaths with very high success rates. On the basis of the systematic implementation of a stepwise approach, we aimed to identify those characteristics that can predict the need for advanced LE techniques. METHODS: Between April 2005 and March 2012, 208 consecutive LE procedures were performed and 456 leads were extracted using an initial superior approach. Advanced techniques for LE (step 4 according to our stepwise approach) were used in 122 patients (58.7%). RESULTS: Younger patient age (odds ratio [OR] = 0.963, P = 0.002), longer duration of the initial implantation (OR = 1.013, P = 0.002), the number of extracted leads (OR = 2.184, P < 0.001), and the presence of right ventricular defibrillator leads (OR = 2.144, P = 0.049) independently predicted the necessity of using step 4 in multivariate analysis. A prediction tool was created taking into account four categorical variables derived even from Receiver Operating Curve analysis of quantitative characteristics (age < 70.7 years, implant duration > 37 months, extraction of at least two leads, one of them being a defibrillator lead). The absence of all the four characteristics was accompanied by 0% positive predictive value for the requirement of step 4 for LE, whereas the coexistence of all four risk factors is characterized by 87% requirement of advanced LE. CONCLUSION: In most of the patients with indication for LE, use of a powered sheath extraction is necessary in order to obtain clinical success. We have identified four patient and lead characteristics that may help the operator plan the means of extraction.


Assuntos
Algoritmos , Remoção de Dispositivo/estatística & dados numéricos , Eletrodos Implantados/estatística & dados numéricos , Falha de Equipamento/estatística & dados numéricos , Cardiopatias/epidemiologia , Cardiopatias/prevenção & controle , Complicações Pós-Operatórias/epidemiologia , Adulto , Distribuição por Idade , Idoso , Idoso de 80 Anos ou mais , Remoção de Dispositivo/instrumentação , Feminino , Humanos , Itália/epidemiologia , Masculino , Pessoa de Meia-Idade , Prevalência , Prognóstico , Estudos Retrospectivos , Fatores de Risco , Distribuição por Sexo , Resultado do Tratamento , Adulto Jovem
16.
J Clin Med ; 12(4)2023 Feb 16.
Artigo em Inglês | MEDLINE | ID: mdl-36836084

RESUMO

BACKGROUND: Cerebral protection devices (CPD) are designed to prevent cardioembolic stroke and most evidence that exists relates to TAVR procedures. There are missing data on the benefits of CPD in patients that are considered high risk for stroke undergoing cardiac procedures like left atrial appendage (LAA) closure or catheter ablation of ventricular tachycardia (VT) when cardiac thrombus is present. PURPOSE: This work aimed to examine the feasibility and safety of the routine use of CPD in patients with cardiac thrombus undergoing interventions in the electrophysiology (EP) lab of a large referral center. METHODS: The CPD was placed under fluoroscopic guidance in all procedures in the beginning of the intervention. Two different CPDs were used according to the physician's discretion: (1) a capture device consisting of two filters for the brachiocephalic and left common carotid arteries placed over a 6F sheath from a radial artery; or (2) a deflection device covering all three supra-aortic vessels placed over an 8F femoral sheath. Retrospective periprocedural and safety data were obtained from procedural reports and discharge letters. Long-term safety data were obtained by clinical follow-up in our institution and telephone consultations. RESULTS: We identified 30 consecutive patients in our EP lab who underwent interventions (21 LAA closure, 9 VT ablation) with placement of a CPD due to cardiac thrombus. Mean age was 70 ± 10 years and 73% were male, while mean LVEF was 40 ± 14%. The location of the cardiac thrombus was the LAA in all 21 patients (100%) undergoing LAA-closure, whereas, in the 9 patients undergoing VT ablation, thrombus was present in the LAA in 5 cases (56%), left ventricle (n = 3, 33%) and aortic arch (n = 1, 11%). The capture device was used in 19 out of 30 (63%) and the deflection device in 11 out of 30 cases (37%). There were no periprocedural strokes or transitory ischemic attacks (TIA). CPD-related complications comprised the vascular access and were as follows: two cases of pseudoaneurysm of the femoral artery not requiring surgery (7%), 1 hematoma at the arterial puncture site (3%) and 1 venous thrombosis (3%) resolved by warfarin. At long-term follow-up, 1 TIA and 2 non-cardiovascular deaths occurred, with a mean follow-up time of 660 days. CONCLUSIONS: Placement of a cerebral protection device prior to LAA closure or VT ablation in patients with cardiac thrombus proved feasible, but possible vascular complications needed to be taken into account. A benefit in periprocedural stroke prevention for these interventions seemed plausible but has yet to be proven in larger and randomized trials.

17.
JACC Case Rep ; 28: 102090, 2023 Dec 20.
Artigo em Inglês | MEDLINE | ID: mdl-38204541

RESUMO

We report a case of patient with a single-chamber Hisian pacemaker who developed complete atrioventricular block and significant deterioration of the ventricular threshold and sensing after transcatheter aortic valve replacement. Revision of the implantation was required, with ventricular lead extraction and replacement.

18.
Panminerva Med ; 65(2): 227-233, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-34664480

RESUMO

BACKGROUND: Patients with non-valvular atrial fibrillation (nvAF) who experienced a cardioembolic (CE) event despite adequate oral anticoagulation (OAC) are at high risk of recurrence, and further prevention strategies are deemed necessary. The present study aimed to evaluate the safety and efficacy of off-label use of left atrial appendage closure (LAAC) in this subset of patients. METHODS: Seventy-five consecutive patients with nvAF who experienced a CE event despite adequate OAC therapy were retrospectively enrolled from two Italian centers. Patients were divided according to the treatment strategy following the index event: DOAC group (49 patients who continued OAC therapy with DOACs) and LAAC group (26 patients who underwent LAAC procedure). 1:1 propensity-score matching between the two groups was performed. LAAC group was made up of two subgroups according to the post-procedural pharmacological regimen: 1) dual antiplatelet therapy (DAPT) for 3 months followed by indefinite single antiplatelet therapy (LAAC+SAPT); or 2) aspirin plus DOAC for 3 months followed by indefinite DOAC therapy (LAAC+DOAC). The primary endpoint was a composite of CE event, major bleeding, or procedure-related major complication. RESULTS: During a median follow-up of 3.4 years (IQR: 2.0-5.3), LAAC was a predictor of primary endpoint-free survival (HR=0.28, 95% CI: 0.08-0.97; P=0.044); within LAAC group, no procedure-related major complication occurred. Moreover, a trend toward a lower rate of both CE events and major bleedings was observed in LAAC group, particularly in the subgroup LAAC+DOAC. CONCLUSIONS: LAAC is a reasonable therapeutic option in nvAF patients who suffered a CE event despite adequate OAC therapy.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Acidente Vascular Cerebral , Humanos , Acidente Vascular Cerebral/prevenção & controle , Acidente Vascular Cerebral/complicações , Estudos Retrospectivos , Apêndice Atrial/cirurgia , Aspirina/efeitos adversos , Fibrilação Atrial/complicações , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/tratamento farmacológico , Hemorragia/induzido quimicamente , Hemorragia/complicações , Anticoagulantes/efeitos adversos , Resultado do Tratamento
19.
J Arrhythm ; 38(2): 192-198, 2022 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-35387138

RESUMO

Background: Temporary pacing is necessary in pacemaker-dependent patients after transvenous lead extraction (TLE) for cardiac implantable electronic device infection. In case of unavailability of other accesses, we propose to use the ipsilateral subclavian access (ISA) combined with a standard permanent active fixation lead for the temporary pacemaker and present preliminary data. Methods: We consecutively enrolled patients undergoing TLE who received a temporary pacemaker using the ISA between August 2016 and April 2020 at our centre. Results: During the observation period, 36 patients undergoing TLE for pocket infection (72.2%), endocarditis (25.0%) or other causes received a temporary pacemaker over the ISA. Their mean age was 77.0 ± 10.7 years, and 13.9% were female. Complete TLE was achieved in 94.4%. There were no major periprocedural complications. Intra-hospital mortality was 11.1%. Pocket revision was performed in 19.4%. During long-term follow-up (23 ± 13 months), 8.3% had a relapse of local pocket infection and 2.8% needed rehospitalization for reintervention. Conclusions: Temporary pacing using a standard permanent active fixation lead using the ISA is a convenient alternative to conventional venous accesses. However, risks of implanting a lead into a previously infected area have to be taken into account.

20.
J Clin Med ; 11(16)2022 Aug 19.
Artigo em Inglês | MEDLINE | ID: mdl-36013123

RESUMO

Background: Limited data is available about the outcome of TLE in patients with vs. without high energy leads in the last decade. Methods: This is an analysis of consecutive patients undergoing TLE at a high-volume TLE centre from 2001 to 2021 using the stepwise approach. Baseline characteristics, procedural details and outcome of patients with high energy lead (ICD group) vs. without high energy lead (non-ICD group) were compared. Results: Out of 667 extractions, 991 leads were extracted in 405 procedures (60.7%) in the ICD group and 439 leads in 262 procedures (39.3%) in the non-ICD group. ICD patients were significantly younger (median 67 vs. 74 years) and were significantly less often female (18.1% vs. 27.7%, p < 0.005 for both). Advanced extraction tools were used significantly more often in the ICD group (73.2% vs. 37.5%, p < 0.001), but there were no significant differences in the successful removal (98.8% vs. 99.2%) or complications (4.7% vs. 3.1%) between the groups (p > 0.2 for both). Discussion: Using the stepwise approach, overall procedural success was high and complication rate was low in a high-volume centre. In patients with a high energy lead, the TLE procedure was more complex, but outcome was similar to comparator patients.

SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa