Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
J Chromatogr A ; 1663: 462771, 2022 Jan 25.
Artigo em Inglês | MEDLINE | ID: mdl-34973481

RESUMO

In the first part of this study, a unified chromatography (UC) analysis method, which is similar to supercritical fluid chromatography (SFC) but with wide mobile phase gradients of pressurized CO2 and solvent, was developed to analyse short-chain peptides, with UV and mass spectrometry (MS) detection. In this second part, the method is compared to a reference reversed-phase ultra-high-performance liquid chromatography (RP-UHPLC) method, based on the analysis of 43 peptides, including 10 linear peptides and 33 cyclic ones. First, the orthogonality between the two methods was examined, based on the retention patterns. As the UC method was developed on a polar stationary phase (Ascentis Express OH5), the elution orders and selectivities were expected to be significantly different from RPLC on a non-polar stationary phase (ACQUITY CSH C18). Secondly, the success rate of the methods was examined, based on successful retention / elution of the peptides and the absence of observed co-elutions between the main peak and impurities. A successful analysis was obtained for 81% of the peptides in UC and 67% in RPLC. Thirdly, the performance of the methods for the intended application of impurity profiling of peptide drug candidates was assessed, based on the comparison of peak purities, the number of impurities detected and the thorough examination of impurity profiles. Excellent complementarity of the two methods for the specific task of impurity profiling, and for the separation of isomeric species was observed, with only one isomeric pair in this set remaining unresolved. The method sensitivity was however better with RPLC than UC. Finally, the operational costs in terms of solvent cost per analysis were the same between the two methods.


Assuntos
Cromatografia com Fluido Supercrítico , Espectrometria de Massas por Ionização por Electrospray , Cromatografia Líquida de Alta Pressão , Cromatografia de Fase Reversa , Peptídeos
2.
Artigo em Inglês | MEDLINE | ID: mdl-36370684

RESUMO

The chromatographic analysis of long-chain hydrophilic therapeutic peptides, with molecular weight mostly in the 3500-4500 Da range (31-34 amino acids), is explored with pressurized CO2 in the mobile phase. The optimal method was obtained on a Torus 2-PIC column, with a gradient elution of 50-90% co-solvent in CO2, which is relevant of enhanced-fluidity liquid chromatography (EFLC). Both UV (210 nm) and mass spectrometric detection modes were employed to assess the purity of the major peak and its resolution from impurities. Ten out of the eleven peptides in this set were basic, thus they were analyzed as acetate or trifluoroacetate salts. As significant peak distortion was observed in some cases, thorough examination of dilution solvent and injection volume was conducted to improve peak shape and resolution from impurities. Finally, the best injection volume was 1 µL, as any other volume (smaller or larger) yielded distorted peaks, and the best dilution solvent composition was the same as the mobile phase co-solvent (methanol comprising 5% water and 0.1 % methanesulfonic acid). However, not all peptide salts were fully soluble in this solvent so other alternatives (including more water in the dilution solvent), offering adequate dissolution but slightly inferior chromatographic performance should be chosen in such cases.


Assuntos
Dióxido de Carbono , Cromatografia com Fluido Supercrítico , Solventes/química , Dióxido de Carbono/química , Cromatografia com Fluido Supercrítico/métodos , Sais , Metanol/química , Água/química , Peptídeos
3.
J Chromatogr A ; 1658: 462631, 2021 Nov 22.
Artigo em Inglês | MEDLINE | ID: mdl-34700137

RESUMO

A method to analyse short-chain bioactive peptides (MW < 800 Da) and their impurities was developed with a unified chromatography (UC) analysis, including a wide mobile phase gradient ranging from supercritical fluid to near-liquid conditions, with UV and electrospray ionization mass spectrometry detection (ESI-MS). Four stationary phases and three mobile phase compositions were examined. Ten model peptides were first selected to identify the best operating conditions, including five linear tripeptides and five cyclic pentapeptides, with log P values ranging from -5.9 to 3.6, and including isomeric species. Derringer desirability functions were designed to identify optimal operating conditions based on 7 criteria, namely the number of peaks detected (including all impurities resolved), the proportion of the chromatogram occupied by target peaks, the least favourable resolution observed between the main peptide and impurities, peak shape features (asymmetry and peak width at half height), and finally the signal-to-noise ratio observed both with UV (210 nm) and ESI-MS in positive ionization mode. The optimum conditions were obtained on Ascentis Express OH5 stationary phase, with a mobile phase composed of carbon dioxide and methanol, comprising 2% water and 20 mM ammonium hydroxide. The final gradient program ranged from 5 to 80% co-solvent in CO2, with a reversed flow rate gradient ranging from 3.0 to 1.5 mL/min. Back-pressure was set at 120 bar and the column oven temperature at 60°C. Optimal conditions were applied to a large set of 76 peptides (34 linear tripeptides and 42 cyclic pentapeptides) and provided adequate scattering of the peaks in the retention space, together with some separation of isomeric species, particularly for the cyclic peptides.


Assuntos
Cromatografia com Fluido Supercrítico , Espectrometria de Massas por Ionização por Electrospray , Metanol , Peptídeos , Solventes
4.
J Pharm Biomed Anal ; 203: 114206, 2021 Sep 05.
Artigo em Inglês | MEDLINE | ID: mdl-34146950

RESUMO

Modern supercritical fluid chromatography (SFC) is now a well-established technique, especially in the field of pharmaceutical analysis. We recently demonstrated the transferability and the reproducibility of a SFC-UV method for pharmaceutical impurities by means of an inter-laboratory study. However, as this study involved only one brand of SFC instrumentation (Waters®), the present study extends the purpose to multi-instrumentation evaluation. Specifically, three instrument types, namely Agilent®, Shimadzu®, and Waters®, were included through 21 laboratories (n = 7 for each instrument). First, method transfer was performed to assess the separation quality and to set up the specific instrument parameters of Agilent® and Shimadzu® instruments. Second, the inter-laboratory study was performed following a protocol defined by the sending lab. Analytical results were examined regarding consistencies within- and between-laboratories criteria. Afterwards, the method reproducibility was estimated taking into account variances in replicates, between-days and between-laboratories. Reproducibility variance was larger than that observed during the first study involving only one single type of instrumentation. Indeed, we clearly observed an 'instrument type' effect. Moreover, the reproducibility variance was larger when considering all instruments than each type separately which can be attributed to the variability induced by the instrument configuration. Nevertheless, repeatability and reproducibility variances were found to be similar than those described for LC methods; i.e. reproducibility as %RSD was around 15 %. These results highlighted the robustness and the power of modern analytical SFC technologies to deliver accurate results for pharmaceutical quality control analysis.


Assuntos
Cromatografia com Fluido Supercrítico , Preparações Farmacêuticas , Controle de Qualidade , Reprodutibilidade dos Testes
5.
J Pharm Biomed Anal ; 170: 40-47, 2019 Jun 05.
Artigo em Inglês | MEDLINE | ID: mdl-30904738

RESUMO

A stressed degradation (oxidation) was employed to produce metabolites from an active pharmaceutical ingredient (API) with large molecular weight (about 900 g/mol). An analytical chromatographic method was desired to compare the products generated by different degradation methods while a multi-gram-scale preparative chromatographic method was necessary to purify the produced metabolites. Supercritical fluid chromatography (SFC) was selected for both tasks as no other chromatographic method had achieved the resolution of the API and metabolites (two isomeric mono-oxide species and one di-oxide). First, an analytical-scale method was developed with ultra-high performance supercritical fluid chromatography (UHPSFC). Achiral stationary phases containing sub-2 µm fully porous particles or sub-3 µm superficially porous particles, and chiral phases containing 3 and 5 µm fully porous particles were selected for a first screening with gradient elution (carbon dioxide - methanol containing additives). The stationary phase providing the most promising results was ACQUITY Torus 2-PIC (100 x 3 mm, 1.7 µm, Waters). A central composite design (CCD) was conducted to optimize the gradient program and oven temperature. Final gradient conditions were as follows: 50-70% methanol in 3.8 min with oven temperature set at 36 °C, back-pressure set at 11 MPa and flow-rate at 0.8 mL/min. The optimized method was employed to analyze samples obtained with different degradation conditions. Then the method was adapted and transferred to preparative-scale SFC on a 5 µm-particles Torus 2-PIC stationary phase (150 x 30 mm). The method was modified to comprise an isocratic step followed by a gradient, favoring peak shape of the last eluting compound and minimal volume of collected fractions. Batch injections in gradient mode were carried out to purify six grams of crude product.


Assuntos
Cromatografia com Fluido Supercrítico/métodos , Preparações Farmacêuticas/química , Dióxido de Carbono/química , Metanol/química , Tamanho da Partícula , Porosidade , Solventes/química , Temperatura
6.
J Pharm Biomed Anal ; 161: 414-424, 2018 Nov 30.
Artigo em Inglês | MEDLINE | ID: mdl-30216790

RESUMO

Supercritical Fluid Chromatography (SFC) has known a strong regain of interest for the last 10 years, especially in the field of pharmaceutical analysis. Besides the development and validation of the SFC method in one individual laboratory, it is also important to demonstrate its applicability and transferability to various laboratories around the world. Therefore, an inter-laboratory study was conducted and published for the first time in SFC, to assess method reproducibility, and evaluate whether this chromatographic technique could become a reference method for quality control (QC) laboratories. This study involved 19 participating laboratories from 4 continents and 9 different countries. It included 5 academic groups, 3 demonstration laboratories at analytical instrument companies, 10 pharmaceutical companies and 1 food company. In the initial analysis of the study results, consistencies within- and between-laboratories were deeply examined. In the subsequent analysis, the method reproducibility was estimated taking into account variances in replicates, between-days and between-laboratories. The results obtained were compared with the literature values for liquid chromatography (LC) in the context of impurities determination. Repeatability and reproducibility variances were found to be similar or better than those described for LC methods, and highlighted the adequacy of the SFC method for QC analyses. The results demonstrated the excellent and robust quantitative performance of SFC. Consequently, this complementary technique is recognized on equal merit to other chromatographic techniques.


Assuntos
Cromatografia com Fluido Supercrítico/normas , Contaminação de Medicamentos/prevenção & controle , Cooperação Internacional , Cromatografia Líquida/métodos , Cromatografia Líquida/normas , Cromatografia com Fluido Supercrítico/métodos , Controle de Qualidade , Reprodutibilidade dos Testes
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa