Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 16 de 16
Filtrar
1.
Cereb Cortex ; 31(8): 3678-3700, 2021 07 05.
Artigo em Inglês | MEDLINE | ID: mdl-33749727

RESUMO

Despite ongoing advances in our understanding of local single-cellular and network-level activity of neuronal populations in the human brain, extraordinarily little is known about their "intermediate" microscale local circuit dynamics. Here, we utilized ultra-high-density microelectrode arrays and a rare opportunity to perform intracranial recordings across multiple cortical areas in human participants to discover three distinct classes of cortical activity that are not locked to ongoing natural brain rhythmic activity. The first included fast waveforms similar to extracellular single-unit activity. The other two types were discrete events with slower waveform dynamics and were found preferentially in upper cortical layers. These second and third types were also observed in rodents, nonhuman primates, and semi-chronic recordings from humans via laminar and Utah array microelectrodes. The rates of all three events were selectively modulated by auditory and electrical stimuli, pharmacological manipulation, and cold saline application and had small causal co-occurrences. These results suggest that the proper combination of high-resolution microelectrodes and analytic techniques can capture neuronal dynamics that lay between somatic action potentials and aggregate population activity. Understanding intermediate microscale dynamics in relation to single-cell and network dynamics may reveal important details about activity in the full cortical circuit.


Assuntos
Córtex Cerebral/fisiologia , Neurônios/fisiologia , Estimulação Acústica , Adulto , Animais , Estimulação Elétrica , Eletroencefalografia , Fenômenos Eletrofisiológicos , Epilepsia/fisiopatologia , Espaço Extracelular/fisiologia , Feminino , Humanos , Macaca mulatta , Imageamento por Ressonância Magnética , Masculino , Camundongos , Camundongos Endogâmicos C57BL , Camundongos Endogâmicos ICR , Microeletrodos , Pessoa de Meia-Idade , Córtex Somatossensorial/fisiologia , Análise de Ondaletas , Adulto Jovem
2.
Epilepsy Behav ; 32: 102-7, 2014 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-24531133

RESUMO

The intrarater and interrater reliability (I&IR) of EEG interpretation has significant implications for the value of EEG as a diagnostic tool. We measured both the intrarater reliability and the interrater reliability of EEG interpretation based on the interpretation of complete EEGs into standard diagnostic categories and rater confidence in their interpretations and investigated sources of variance in EEG interpretations. During two distinct time intervals, six board-certified clinical neurophysiologists classified 300 EEGs into one or more of seven diagnostic categories and assigned a subjective confidence to their interpretations. Each EEG was read by three readers. Each reader interpreted 150 unique studies, and 50 studies were re-interpreted to generate intrarater data. A generalizability study assessed the contribution of subjects, readers, and the interaction between subjects and readers to interpretation variance. Five of the six readers had a median confidence of ≥99%, and the upper quartile of confidence values was 100% for all six readers. Intrarater Cohen's kappa (κc) ranged from 0.33 to 0.73 with an aggregated value of 0.59. Cohen's kappa ranged from 0.29 to 0.62 for the 15 reader pairs, with an aggregated Fleiss kappa of 0.44 for interrater agreement. Cohen's kappa was not significantly different across rater pairs (chi-square=17.3, df=14, p=0.24). Variance due to subjects (i.e., EEGs) was 65.3%, due to readers was 3.9%, and due to the interaction between readers and subjects was 30.8%. Experienced epileptologists have very high confidence in their EEG interpretations and low to moderate I&IR, a common paradox in clinical medicine. A necessary, but insufficient, condition to improve EEG interpretation accuracy is to increase intrarater and interrater reliability. This goal could be accomplished, for instance, with an automated online application integrated into a continuing medical education module that measures and reports EEG I&IR to individual users.


Assuntos
Eletroencefalografia/métodos , Variações Dependentes do Observador , Convulsões/diagnóstico , Adulto , Humanos , Masculino , Reprodutibilidade dos Testes , Convulsões/etiologia
3.
Clin Neurophysiol Pract ; 8: 177-186, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37681118

RESUMO

Objective: Misinterpretation of EEGs harms patients, yet few resources exist to help trainees practice interpreting EEGs. We therefore sought to evaluate a novel educational tool to teach trainees how to identify interictal epileptiform discharges (IEDs) on EEG. Methods: We created a public EEG test within the iOS app DiagnosUs using a pool of 13,262 candidate IEDs. Users were shown a candidate IED on EEG and asked to rate it as epileptiform (IED) or not (non-IED). They were given immediate feedback based on a gold standard. Learning was analyzed using a parametric model. We additionally analyzed IED features that best correlated with expert ratings. Results: Our analysis included 901 participants. Users achieved a mean improvement of 13% over 1,000 questions and an ending accuracy of 81%. Users and experts appeared to rely on a similar set of IED morphologic features when analyzing candidate IEDs. We additionally identified particular types of candidate EEGs that remained challenging for most users even after substantial practice. Conclusions: Users improved in their ability to properly classify candidate IEDs through repeated exposure and immediate feedback. Significance: This app-based learning activity has great potential to be an effective supplemental tool to teach neurology trainees how to accurately identify IEDs on EEG.

4.
Brain ; 134(Pt 10): 2948-59, 2011 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-21903727

RESUMO

Transient high-frequency (100-500 Hz) oscillations of the local field potential have been studied extensively in human mesial temporal lobe. Previous studies report that both ripple (100-250 Hz) and fast ripple (250-500 Hz) oscillations are increased in the seizure-onset zone of patients with mesial temporal lobe epilepsy. Comparatively little is known, however, about their spatial distribution with respect to seizure-onset zone in neocortical epilepsy, or their prevalence in normal brain. We present a quantitative analysis of high-frequency oscillations and their rates of occurrence in a group of nine patients with neocortical epilepsy and two control patients with no history of seizures. Oscillations were automatically detected and classified using an unsupervised approach in a data set of unprecedented volume in epilepsy research, over 12 terabytes of continuous long-term micro- and macro-electrode intracranial recordings, without human preprocessing, enabling selection-bias-free estimates of oscillation rates. There are three main results: (i) a cluster of ripple frequency oscillations with median spectral centroid = 137 Hz is increased in the seizure-onset zone more frequently than a cluster of fast ripple frequency oscillations (median spectral centroid = 305 Hz); (ii) we found no difference in the rates of high frequency oscillations in control neocortex and the non-seizure-onset zone neocortex of patients with epilepsy, despite the possibility of different underlying mechanisms of generation; and (iii) while previous studies have demonstrated that oscillations recorded by parenchyma-penetrating micro-electrodes have higher peak 100-500 Hz frequencies than penetrating macro-electrodes, this was not found for the epipial electrodes used here to record from the neocortical surface. We conclude that the relative rate of ripple frequency oscillations is a potential biomarker for epileptic neocortex, but that larger prospective studies correlating high-frequency oscillations rates with seizure-onset zone, resected tissue and surgical outcome are required to determine the true predictive value.


Assuntos
Ondas Encefálicas/fisiologia , Epilepsia/fisiopatologia , Neocórtex/fisiopatologia , Adulto , Mapeamento Encefálico/métodos , Eletrodos Implantados , Eletroencefalografia/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos
5.
Expert Syst Appl ; 39(8): 7355-7370, 2012 Jun 15.
Artigo em Inglês | MEDLINE | ID: mdl-23105174

RESUMO

Localizing an epileptic network is essential for guiding neurosurgery and antiepileptic medical devices as well as elucidating mechanisms that may explain seizure-generation and epilepsy. There is increasing evidence that pathological oscillations may be specific to diseased networks in patients with epilepsy and that these oscillations may be a key biomarker for generating and indentifying epileptic networks. We present a semi-automated method that detects, maps, and mines pathological gamma (30-100 Hz) oscillations (PGOs) in human epileptic brain to possibly localize epileptic networks. We apply the method to standard clinical iEEG (<100 Hz) with interictal PGOs and seizures from six patients with medically refractory epilepsy. We demonstrate that electrodes with consistent PGO discharges do not always coincide with clinically determined seizure onset zone (SOZ) electrodes but at times PGO-dense electrodes include secondary seizure-areas (SS) or even areas without seizures (NS). In 4/5 patients with epilepsy surgery, we observe poor (Engel Class 4) post-surgical outcomes and identify more PGO-activity in SS or NS than in SOZ. Additional studies are needed to further clarify the role of PGOs in epileptic brain.

6.
Epileptic Disord ; 24(3): 496-506, 2022 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-35770748

RESUMO

OBJECTIVE: Interictal epileptiform discharges on EEG are integral to diagnosing epilepsy. However, EEGs are interpreted by readers with and without specialty training, and there is no accepted method to assess skill in interpretation. We aimed to develop a test to quantify IED recognition skills. METHODS: A total of 13,262 candidate IEDs were selected from EEGs and scored by eight fellowship-trained reviewers to establish a gold standard. An online test was developed to assess how well readers with different training levels could distinguish candidate waveforms. Sensitivity, false positive rate and calibration were calculated for each reader. A simple mathematical model was developed to estimate each reader's skill and threshold in identifying an IED, and to develop receiver operating characteristics curves for each reader. We investigated the number of IEDs needed to measure skill level with acceptable precision. RESULTS: Twenty-nine raters completed the test; nine experts, seven experienced non-experts and thirteen novices. Median calibration errors for experts, experienced non-experts and novices were -0.056, 0.012, 0.046; median sensitivities were 0.800, 0.811, 0.715; and median false positive rates were 0.177, 0.272, 0.396, respectively. The number of test questions needed to measure those scores was 549. Our analysis identified that novices had a higher noise level (uncertainty) compared to experienced non-experts and experts. Using calculated noise and threshold levels, receiver operating curves were created, showing increasing median area under the curve from novices (0.735), to experienced non-experts (0.852) and experts (0.891). SIGNIFICANCE: Expert and non-expert readers can be distinguished based on ability to identify IEDs. This type of assessment could also be used to identify and correct differences in thresholds in identifying IEDs.


Assuntos
Eletroencefalografia , Epilepsia , Eletroencefalografia/métodos , Epilepsia/diagnóstico , Humanos , Tempo
7.
Clin Neurophysiol ; 132(11): 2916-2931, 2021 11.
Artigo em Inglês | MEDLINE | ID: mdl-34419344

RESUMO

OBJECTIVE: Interictal discharges (IIDs) and high frequency oscillations (HFOs) are established neurophysiologic biomarkers of epilepsy, while microseizures are less well studied. We used custom poly(3,4-ethylenedioxythiophene) polystyrene sulfonate (PEDOT:PSS) microelectrodes to better understand these markers' microscale spatial dynamics. METHODS: Electrodes with spatial resolution down to 50 µm were used to record intraoperatively in 30 subjects. IIDs' degree of spread and spatiotemporal paths were generated by peak-tracking followed by clustering. Repeating HFO patterns were delineated by clustering similar time windows. Multi-unit activity (MUA) was analyzed in relation to IID and HFO timing. RESULTS: We detected IIDs encompassing the entire array in 93% of subjects, while localized IIDs, observed across < 50% of channels, were seen in 53%. IIDs traveled along specific paths. HFOs appeared in small, repeated spatiotemporal patterns. Finally, we identified microseizure events that spanned 50-100 µm. HFOs covaried with MUA, but not with IIDs. CONCLUSIONS: Overall, these data suggest that irritable cortex micro-domains may form part of an underlying pathologic architecture which could contribute to the seizure network. SIGNIFICANCE: These results, supporting the possibility that epileptogenic cortex comprises a mosaic of irritable domains, suggests that microscale approaches might be an important perspective in devising novel seizure control therapies.


Assuntos
Mapeamento Encefálico/métodos , Encéfalo/fisiopatologia , Eletroencefalografia/métodos , Epilepsia/fisiopatologia , Monitorização Neurofisiológica Intraoperatória/métodos , Microeletrodos , Adulto , Encéfalo/cirurgia , Eletroencefalografia/instrumentação , Epilepsia/diagnóstico , Epilepsia/cirurgia , Feminino , Humanos , Monitorização Neurofisiológica Intraoperatória/instrumentação , Masculino , Pessoa de Meia-Idade , Adulto Jovem
8.
JAMA Neurol ; 77(1): 103-108, 2020 01 01.
Artigo em Inglês | MEDLINE | ID: mdl-31633740

RESUMO

Importance: Interictal epileptiform discharges (IEDs) in electroencephalograms (EEGs) are a biomarker of epilepsy, seizure risk, and clinical decline. However, there is a scarcity of experts qualified to interpret EEG results. Prior attempts to automate IED detection have been limited by small samples and have not demonstrated expert-level performance. There is a need for a validated automated method to detect IEDs with expert-level reliability. Objective: To develop and validate a computer algorithm with the ability to identify IEDs as reliably as experts and classify an EEG recording as containing IEDs vs no IEDs. Design, Setting, and Participants: A total of 9571 scalp EEG records with and without IEDs were used to train a deep neural network (SpikeNet) to perform IED detection. Independent training and testing data sets were generated from 13 262 IED candidates, independently annotated by 8 fellowship-trained clinical neurophysiologists, and 8520 EEG records containing no IEDs based on clinical EEG reports. Using the estimated spike probability, a classifier designating the whole EEG recording as positive or negative was also built. Main Outcomes and Measures: SpikeNet accuracy, sensitivity, and specificity compared with fellowship-trained neurophysiology experts for identifying IEDs and classifying EEGs as positive or negative or negative for IEDs. Statistical performance was assessed via calibration error and area under the receiver operating characteristic curve (AUC). All performance statistics were estimated using 10-fold cross-validation. Results: SpikeNet surpassed both expert interpretation and an industry standard commercial IED detector, based on calibration error (SpikeNet, 0.041; 95% CI, 0.033-0.049; vs industry standard, 0.066; 95% CI, 0.060-0.078; vs experts, mean, 0.183; range, 0.081-0.364) and binary classification performance based on AUC (SpikeNet, 0.980; 95% CI, 0.977-0.984; vs industry standard, 0.882; 95% CI, 0.872-0.893). Whole EEG classification had a mean calibration error of 0.126 (range, 0.109-0.1444) vs experts (mean, 0.197; range, 0.099-0.372) and AUC of 0.847 (95% CI, 0.830-0.865). Conclusions and Relevance: In this study, SpikeNet automatically detected IEDs and classified whole EEGs as IED-positive or IED-negative. This may be the first time an algorithm has been shown to exceed expert performance for IED detection in a representative sample of EEGs and may thus be a valuable tool for expedited review of EEGs.


Assuntos
Eletroencefalografia , Epilepsia/diagnóstico , Redes Neurais de Computação , Processamento de Sinais Assistido por Computador , Software , Humanos , Sensibilidade e Especificidade
9.
JAMA Neurol ; 77(1): 49-57, 2020 01 01.
Artigo em Inglês | MEDLINE | ID: mdl-31633742

RESUMO

Importance: The validity of using electroencephalograms (EEGs) to diagnose epilepsy requires reliable detection of interictal epileptiform discharges (IEDs). Prior interrater reliability (IRR) studies are limited by small samples and selection bias. Objective: To assess the reliability of experts in detecting IEDs in routine EEGs. Design, Setting, and Participants: This prospective analysis conducted in 2 phases included as participants physicians with at least 1 year of subspecialty training in clinical neurophysiology. In phase 1, 9 experts independently identified candidate IEDs in 991 EEGs (1 expert per EEG) reported in the medical record to contain at least 1 IED, yielding 87 636 candidate IEDs. In phase 2, the candidate IEDs were clustered into groups with distinct morphological features, yielding 12 602 clusters, and a representative candidate IED was selected from each cluster. We added 660 waveforms (11 random samples each from 60 randomly selected EEGs reported as being free of IEDs) as negative controls. Eight experts independently scored all 13 262 candidates as IEDs or non-IEDs. The 1051 EEGs in the study were recorded at the Massachusetts General Hospital between 2012 and 2016. Main Outcomes and Measures: Primary outcome measures were percentage of agreement (PA) and beyond-chance agreement (Gwet κ) for individual IEDs (IED-wise IRR) and for whether an EEG contained any IEDs (EEG-wise IRR). Secondary outcomes were the correlations between numbers of IEDs marked by experts across cases, calibration of expert scoring to group consensus, and receiver operating characteristic analysis of how well multivariate logistic regression models may account for differences in the IED scoring behavior between experts. Results: Among the 1051 EEGs assessed in the study, 540 (51.4%) were those of females and 511 (48.6%) were those of males. In phase 1, 9 experts each marked potential IEDs in a median of 65 (interquartile range [IQR], 28-332) EEGs. The total number of IED candidates marked was 87 636. Expert IRR for the 13 262 individually annotated IED candidates was fair, with the mean PA being 72.4% (95% CI, 67.0%-77.8%) and mean κ being 48.7% (95% CI, 37.3%-60.1%). The EEG-wise IRR was substantial, with the mean PA being 80.9% (95% CI, 76.2%-85.7%) and mean κ being 69.4% (95% CI, 60.3%-78.5%). A statistical model based on waveform morphological features, when provided with individualized thresholds, explained the median binary scores of all experts with a high degree of accuracy of 80% (range, 73%-88%). Conclusions and Relevance: This study's findings suggest that experts can identify whether EEGs contain IEDs with substantial reliability. Lower reliability regarding individual IEDs may be largely explained by various experts applying different thresholds to a common underlying statistical model.


Assuntos
Epilepsia/diagnóstico , Eletroencefalografia , Feminino , Humanos , Masculino , Variações Dependentes do Observador , Estudos Prospectivos , Reprodutibilidade dos Testes
10.
Clin Neurophysiol ; 130(6): 1058-1065, 2019 06.
Artigo em Inglês | MEDLINE | ID: mdl-30930194

RESUMO

OBJECTIVE: Intraoperative mapping via electrical stimulation is the gold standard technique for surgeries close to the eloquent cortex. However, it can trigger seizures which immediately impact patient's safety. We studied whether administration of antiepileptic drugs (AED) prior to and/or at the beginning of the surgery decreases the probability of triggering seizures, while adjusting for other risk factors. METHODS: 544 consecutive intraoperative mapping cases performed at a tertiary care center for epilepsy and brain tumor surgery were included in the study. Using a multivariate logistic regression analysis, we analyzed the independent impacts of AED loading at time of surgery, preoperative AED maintenance, history of seizures, type of stimulation paradigm, lobar location of stimulation, age, opioid administration and pathology on the probability of triggering seizures. RESULTS: Seizures were identified in 135 patients. Intravenous loading with AED decreased the odds of triggering seizures by 45% (OR = 0.55, p = 0.01), Penfield (versus multipulse train) stimulation and diffuse (versus well circumscribed) pathology increased it twice (OR = 1.97, p = 0.01) and 2.4 times (OR = 2.42, p = 0.003) respectively. No other factors had a significant impact. CONCLUSIONS: Seizures triggered during mapping occur frequently and are multifactorial. SIGNIFICANCE: Loading with AED independently reduces the risk of their occurrence.


Assuntos
Mapeamento Encefálico/normas , Encéfalo/cirurgia , Complicações Intraoperatórias/prevenção & controle , Monitorização Neurofisiológica Intraoperatória/normas , Convulsões/cirurgia , Adulto , Encéfalo/fisiopatologia , Mapeamento Encefálico/efeitos adversos , Estimulação Elétrica/efeitos adversos , Feminino , Humanos , Complicações Intraoperatórias/etiologia , Complicações Intraoperatórias/fisiopatologia , Monitorização Neurofisiológica Intraoperatória/efeitos adversos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Fatores de Risco , Convulsões/diagnóstico , Convulsões/fisiopatologia
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa