Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 31
Filtrar
1.
Cytokine ; 162: 156118, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-36584453

RESUMO

Cancer develops when multiple systems fail to suppress uncontrolled cell proliferation. Breast cancers and oesophageal squamous cell carcinoma (OSCC) are common cancers prone to genetic instability. They typically occur in acidic microenvironments which impacts on cell proliferation, apoptosis, and their influence on surrounding cells to support tumour growth and immune evasion. This study aimed to evaluate the impact of the acidic tumour microenvironment on the production of pro-tumorigenic and immunomodulatory factors in cancer cell lines. Multiple factors that may mediate immune evasion were secreted including IL-6, IL-8, G-CSF, IP-10, GDF-15, Lipocalin-2, sICAM-1, and myoglobin. Others, such as VEGF, FGF, and EGF that are essential for tumour cell survival were also detected. Treatment with moderate acidity did not significantly affect secretion of most proteins, whereas very low pH did. Distinct differences in apoptosis were noted between the cell lines, with WHCO6 being better adapted to survive at moderate acid levels. Conditioned medium from acid-treated cells stimulated increased cell viability and proliferation in WHCO6, but increased cell death in MCF-7. This study highlights the importance of acidic tumour microenvironment in controlling apoptosis, cell proliferation, and immune evasion which may be different at different anatomical sites. Immunomodulatory molecules and growth factors provide therapeutic targets to improve the prognosis of individuals with cancer.


Assuntos
Neoplasias da Mama , Neoplasias Esofágicas , Humanos , Feminino , Sobrevivência Celular , Linhagem Celular Tumoral , Neoplasias da Mama/patologia , Proliferação de Células/genética , Neoplasias Esofágicas/metabolismo , Ciclo Celular , Microambiente Tumoral
2.
Cytokine ; 165: 156174, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-36996538

RESUMO

BACKGROUND: Human immunodeficiency virus (HIV) infection is prevalent in Africa and causes morbidity and mortality despite antiretroviral therapy (ART). Non-communicable complications of HIV infection include cardiovascular disease (CVD) with thromboses throughout the vascular tree. Ongoing inflammation and endothelial dysfunction in people living with HIV (PLWH) probably contribute significantly to HIV-related CVD. OBJECTIVES: A systematic review was conducted to inform interpretation of 5 biomarkers commonly measured in PLWH namely interleukin-6 (IL-6), tumour necrosis factor alpha (TNF-α), D-dimers, and soluble intracellular and vascular adhesion molecules-1 (sICAM-1 and sVCAM-1) to attempt to define a range for these values in ART naïve PLWH without overt CVD or additional comorbid diseases. METHODS: A systematic search was conducted for all studies documenting the levels of the above biomarkers in ART naïve PLWH published on the PubMed database from 1994 to 2020. RESULTS: The number of publications that reported medians above the assay values was: 4/15 for D-dimer; 0/5 for TNF-α, 8/16 for IL-6, 3/6 for sVCAM-1, and 4/5 for sICAM-1. CONCLUSION: The clinical utility of biomarkers is reduced by the lack of standardisation of the measurement of these parameters, absence of normal reference indices and the lack of uniformity of study protocols in different research centres. This review supports the ongoing use of D-dimers to predict thrombotic and bleeding events in PLWH since the weighted averages across study assays suggest that the median levels do not exceed the reference range. The role of inflammatory cytokine monitoring and measurement of endothelial adhesion markers is less clear.


Assuntos
Doenças Cardiovasculares , Infecções por HIV , Humanos , Infecções por HIV/tratamento farmacológico , Interleucina-6 , Fator de Necrose Tumoral alfa/uso terapêutico , Biomarcadores , HIV
3.
Adv Exp Med Biol ; 1412: 159-173, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37378766

RESUMO

Current biomarkers to assess the risk of complications of both acute and chronic viral infection are suboptimal. Prevalent viral infections like human immunodeficiency virus (HIV), hepatitis B and C virus, herpes viruses, and, more recently, severe acute respiratory syndrome coronavirus-2 (SARS-CoV-2) may be associated with significant sequelae including the risk of cardiovascular disease, other end-organ diseases, and malignancies. This review considers some biomarkers which have been investigated in diagnosis and prognosis of key viral infections including inflammatory cytokines, markers of endothelial dysfunction and activation and coagulation, and the role that more conventional diagnostic markers, such as C-reactive protein and procalcitonin, can play in predicting these secondary complications, as markers of severity and to distinguish viral and bacterial infection. Although many of these are still only available in the research setting, these markers show promise for incorporation in diagnostic algorithms which may assist to predict adverse outcomes and to guide therapy.


Assuntos
COVID-19 , Viroses , Humanos , COVID-19/diagnóstico , SARS-CoV-2 , Viroses/diagnóstico , Biomarcadores , Citocinas
4.
Cytokine ; 157: 155945, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-35841826

RESUMO

Coeliac disease (CD) is an autoimmune disorder and one of the few gastroenteropathies with accurate serological testing. CD serology has decreased accuracy for patients on a gluten-free diet and for monitoring mucosal healing. New ancillary tests would, therefore, be useful. Intestinal Fatty Acid Binding Protein (I-FABP) and CX3CL1 (Fractalkine) are two promising biomarkers for CD but haven't been examined in patients who are at a high-risk for CD such as patients with type one diabetes (TID). This study, therefore, aimed to investigate serum levels of I-FABP and CX3CL1 in a cohort of South African patients with TID at a high-risk of developing CD. The serum I-FABP levels were significantly higher in CD-positive patients compared to CD-negative individuals (p = 0.03). No significant differences in the serum CX3CL1 levels were detected although this may reflect the impact of the comorbid autoimmune diseases had on the serum CX3CL1 levels. In conclusion, this study is the first to assess the levels of these biomarkers in a multiethnic population with comorbid autoimmune disease and determined I-FABP to be the more promising biomarker in such clinical contexts. Future research should focus on a diverse biomarker panel and longitudinal follow-up of patients at a high-risk for CD.


Assuntos
Doença Celíaca , Biomarcadores , Doença Celíaca/diagnóstico , Quimiocina CX3CL1 , Dieta Livre de Glúten , Proteínas de Ligação a Ácido Graxo , Humanos , África do Sul
5.
Clin Lab ; 65(7)2019 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-31307171

RESUMO

BACKGROUND: Verification of the performance of analytical platforms is indicated prior to adoption of new Technology for patient sample analysis. Acceptance criteria for the performance of coagulation analytical platforms are not always readily available and is complicated by the multiple assays and test principles in this section of the clinical laboratory. Coagulation samples are also prone to pre-analytical, post-sample collection variables potentially interfering with accuracy analysis. METHODS: This verification study assessed the accuracy of the automated STAGO STA-R Max® coagulation analyzers by means of a comparison study of results obtained on the previously validated STAGO STA-R Evolution® analyzer for 22 coagulation parameters on 40 individual patient samples for each parameter. Within- and between- run reproducibility on commercial control material, carry-over from abnormal to normal samples and the interference of bilirubin, hemoglobin and lipids on the chromogenic analytical channel were also assessed. Ongoing evaluation of the analyzer performance was assessed by External Quality Assurance (EQA) scheme participation. RESULTS: The reproducibility (precision) on 2 levels (Normal and Pathological) commercial control material was acceptable with co-efficient of variance (CV) results below the manufacturer target % CVs. The correlation study demonstrated accuracy of results obtained on the analyzers for all parameters except for D-dimers and coagulation Factor VII. Subsequent EQA performance for these two parameters were however satisfactory. Interference from bilirubin, hemoglobin and lipids did occur in the chromogenic channel. No clinically significant carry over from abnormal to normal samples were observed. CONCLUSIONS: The performance of the STAGO STA-R Max® analyzer is acceptable across the full coagulation test repertoire with the exception of the von Willebrand activity assay. Participation in EQA scheme assessments will be an integral part of ongoing monitoring of the performance of this automated analyzer.


Assuntos
Automação Laboratorial/instrumentação , Testes de Coagulação Sanguínea/instrumentação , Coagulação Sanguínea , Técnicas de Laboratório Clínico/instrumentação , Garantia da Qualidade dos Cuidados de Saúde , Automação Laboratorial/métodos , Automação Laboratorial/normas , Testes de Coagulação Sanguínea/métodos , Testes de Coagulação Sanguínea/normas , Serviços de Laboratório Clínico/normas , Técnicas de Laboratório Clínico/métodos , Técnicas de Laboratório Clínico/normas , Humanos , Laboratórios/normas , Reprodutibilidade dos Testes , África do Sul
6.
Clin Lab ; 65(4)2019 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-30969088

RESUMO

BACKGROUND: Von Willebrand disease requires laboratory confirmation with quantitative and qualitative measurements of von Willebrand factor (VWF). Qualitative VWF-activity (VWF-Ac) tests have poor inter- and intra-laboratory reproducibility with coefficients of variation (CVs) as high as 64%, often lacking accuracy at low VWF-Ac levels. METHODS: This study evaluated the recently launched immunoturbidometric STAGO® STA-VWF:RCo® reagent for VWF-Ac. Accuracy was evaluated on 32 samples by comparing results using the Siemens® Innovance® reagent. An intra-run reproducibility study was performed on controls. Linearity and lower limit of detection was studied on external-quality-assurance (EQA) material with a known VWF-Ac level. RESULTS: STA-VWF:RCo® reagent results were within clinical interpretation agreement with Siemens® Innovance®. The reproducibility study yielded % CVs of 8.41 for normal and 11.46 for abnormal controls and the assay was linear between 73 and 14.6% and remained linear to 2% with extrapolation. CONCLUSIONS: The STAGO® STA-VWF:RCo® reagent showed clinically meaningful accuracy and acceptable precision.


Assuntos
Testes de Coagulação Sanguínea/métodos , Técnicas de Laboratório Clínico , Imunoturbidimetria/métodos , Doenças de von Willebrand/diagnóstico , Fator de von Willebrand/análise , Testes de Coagulação Sanguínea/normas , Feminino , Humanos , Imunoturbidimetria/normas , Limite de Detecção , Modelos Lineares , Masculino , Reprodutibilidade dos Testes , Doenças de von Willebrand/sangue
8.
Clin Lab ; 64(10): 1649-1654, 2018 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-30336513

RESUMO

BACKGROUND: Suitable laboratory testing prior to transplantation ensures that a patient's immunological risk is understood and allows the transplantation team to make the correct decisions on donor-recipient pairing. Preformed donor-specific anti-HLA antibodies mediate rejection in transplanted patients. Improved laboratory testing is needed to increase the chances of successful organ allocation. In this study, we show how Luminex™ single antigen assays are vital in determining immunological risk to transplantation and in predicting waiting time to transplantation. METHODS: Potential recipients awaiting renal transplantation (deceased donor) were tested using Luminex™ single antigen testing. HLA class I and II antibody specificities were determined, and patient demographics were analyzed for each blood group. Antibody reactivity was compared between patients who were transplanted or not transplanted in each blood group. Immunological risk to successful transplantation was determined retrospectively for all patients. RESULTS: Patient demographics were reported for the cohort. More males await renal transplantation than females (male:female ratio of 1.84:1). The median age of the patients was similar between the blood groups (between 41 and 44.5 years), as was the median time spent on the waiting list (between 3 - 4 years). Patients who were transplanted had significantly reduced HLA antibody expression compared to those who were not transplanted (total median reactivity 2 versus 8%, p = 0.0006). Patients were retrospectively stratified according to HLA antibody expression as a surrogate marker for immunological risk. Those in the high-risk group spent longer on the waiting list and had a low chance of being transplanted. CONCLUSIONS: Risk stratification can be used as a tool in predicting likelihood of successful transplantation. Laboratories in South Africa should move towards implementing highly sensitive, highly specific diagnostic assays in order to improve successful organ allocation. This will aid in standardizing testing algorithms in order to transplant more recipients.


Assuntos
Antígenos HLA/imunologia , Teste de Histocompatibilidade/métodos , Transplante de Rim/estatística & dados numéricos , Doadores de Tecidos , Listas de Espera , Adolescente , Adulto , Idoso , Criança , Feminino , Rejeição de Enxerto/imunologia , Rejeição de Enxerto/prevenção & controle , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , África do Sul , Adulto Jovem
9.
Clin Lab ; 64(7): 1317-1321, 2018 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-30146831

RESUMO

BACKGROUND: The validity of laboratory results depends on pre-analytical variables not detected by conventional quality control. Recommendations are for post-centrifugation coagulation samples to remain capped with cappiercing primary tube analysis. Total laboratory automation integrates analytical platforms with potential incompatibilities necessitating changes including pre-analytical uncapping of samples. METHODS: Samples analyzed for Prothrombin Time (PT), activated Partial Thromboplastin Time (aPTT), D-dimers, Antithrombin and Fibrinogen at baseline, and after 60 and 120 minutes were left at ambient temperature, either re-capped or uncapped, in order to simulate changes from baseline that could occur in uncapped samples on an automation track prior to analysis. Changes were compared to the maximal permissible bias. RESULTS: Sample uncapping for up to 120 minutes at ambient temperature post-centrifugation did not result in clinically significant changes in routine coagulation parameters. CONCLUSIONS: Routine coagulation parameters will not change significantly if the primary citrate tubes are uncapped after centrifugation prior to analysis.


Assuntos
Automação Laboratorial/métodos , Testes de Coagulação Sanguínea/métodos , Coagulação Sanguínea , Manejo de Espécimes/métodos , Antitrombinas/análise , Testes de Coagulação Sanguínea/instrumentação , Centrifugação/métodos , Produtos de Degradação da Fibrina e do Fibrinogênio/análise , Fibrinogênio/análise , Humanos , Tempo de Tromboplastina Parcial , Tempo de Protrombina , Controle de Qualidade , Reprodutibilidade dos Testes , Manejo de Espécimes/instrumentação , Temperatura , Fatores de Tempo
10.
Data Brief ; 54: 110460, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38711735

RESUMO

Cancer cells influence their microenvironment by secreting factors that promote tumour growth and survival while evading immune-mediated destruction. We previously determined the expression of secreted factors in breast and oesophageal squamous cell carcinoma cell lines (MCF-7 and WHCO6, respectively) using Luminex assays. These cells were subsequently treated with low pH medium to mimic in vivo acid exposure, and the effects on cell viability, proliferation, and secretion of cytokines, chemokines and growth factors were described [1]. Here, we present the datasets from these experiments in addition to data obtained from treating cell lines with conditioned medium from apoptotic cell cultures.

11.
PLoS One ; 17(6): e0270599, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35767593

RESUMO

Cell death is important in physiology, and can happen as a result of structural damage, or as a sequence of programmed cellular processes known as apoptosis. Pathogenic alterations in apoptosis occur in a number of diseases, including cancer, viral infections, autoimmune diseases, immunodeficiencies, and degenerative conditions. Developing accurate and reproducible laboratory methods for inducing and detecting apoptosis is vital for research into these conditions. A number of methods are employed to detect cell death, including DNA fragmentation, the TUNEL assay, and electron microscopy although each has its limitations. Flow cytometry allows for the distinction between live, early apoptotic, late apoptotic and necrotic cells. In this protocol we successfully induce apoptosis using chemical treatment and treatment with low pH in solid tumour cell lines, and have optimized detection using the Annexin V/PI apoptosis assay.


Assuntos
Apoptose , Anexina A5/metabolismo , Citometria de Fluxo/métodos , Humanos , Concentração de Íons de Hidrogênio , Necrose
12.
Hum Immunol ; 83(5): 399-408, 2022 May.
Artigo em Inglês | MEDLINE | ID: mdl-35216847

RESUMO

The success of cancer treatment relies on the composition of the tumour microenvironment which is comprised of tumour cells, blood vessels, stromal cells, immune cells, and extracellular matrix components. Barriers to effective cancer treatment need to be overcome, and the acidic microenvironment of the tumour provides a key target for treatment. This review intends to provide an overview of the effects that low extracellular pH has on components of the tumour microenvironment and how they contribute to immune escape. Further, potential therapeutic targets will be discussed.


Assuntos
Neoplasias , Microambiente Tumoral , Humanos , Imunidade , Neoplasias/terapia
13.
PLoS One ; 17(1): e0262306, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35061794

RESUMO

INTRODUCTION: Disseminated intravascular Coagulation (DIC) is a thrombotic microangiopathy which may complicate a number of severe disease processes including sepsis. Development of microvascular thromboses results in consumption of coagulation factors and platelets and ultimate bleeding. Patients with HIV infection (PWH) often present with baseline dysregulation of the coagulation system which may increase severity and derangement of DIC presentation. Previously, we have shown that HIV is a significant risk factor for development of DIC. METHODOLOGY: We conducted a retrospective record review of all DIC screens submitted to our tertiary coagulation laboratory in Johannesburg, South Africa, over a one year period and compared the laboratory presentation of DIC in PWH with presentation of DIC in patients without HIV infection. RESULTS: Over the year, 246 patients fulfilled the International Society of Thrombosis and Haemostasis (ISTH) diagnostic criteria for DIC- 108 were confirmed HIV-infected and 77 were confirmed uninfected. PWH and DIC presented at a significantly earlier age (41 vs 46 years respectively, p<0.02). The prothrombin time was significantly more prolonged (30.1s vs 26.s), the d-dimer levels were substantially higher (5.89mg/L vs 4.52mg/L) and the fibrinogen (3.92g/L vs 1.73g/L) and platelet levels (64.8 vs 114.8x109/l) were significantly lower in PWH. PWH also showed significant synthetic liver dysfunction and higher background inflammation. CONCLUSION: PWH who fulfil the diagnostic criteria for DIC show significantly more dysregulation of the haemostatic system. This may reflect baseline abnormalities including endothelial dysfunction in the context of inflammation and liver dysfunction.


Assuntos
Coagulação Intravascular Disseminada/diagnóstico , Infecções por HIV/complicações , Adulto , Coagulação Sanguínea/fisiologia , Testes de Coagulação Sanguínea , Plaquetas/química , Coagulação Intravascular Disseminada/virologia , Feminino , Fibrinogênio/análise , HIV/patogenicidade , Humanos , Masculino , Pessoa de Meia-Idade , Tempo de Protrombina , Estudos Retrospectivos , Índice de Gravidade de Doença , África do Sul/epidemiologia , Centros de Atenção Terciária , Trombose/complicações
14.
AIDS ; 36(10): 1345-1354, 2022 08 01.
Artigo em Inglês | MEDLINE | ID: mdl-35608117

RESUMO

OBJECTIVE: Investigate the presence of inflammation, endothelial dysfunction and complement activation in patients with HIV-associated thrombotic thrombocytopenic purpura (HIV-TTP) to support the hypothesis that these processes probably contribute to the development of this thrombotic microangiopathy. DESIGN: A prospective, investigational cohort study of 35 consecutive patients diagnosed with HIV-associated TTP presenting to three academic, tertiary care hospitals in Johannesburg, South Africa over 2 years. METHODS: The patients with HIV-TTP received therapeutic plasma therapy and supportive treatment. Demographic data, the results of routine investigations and patient outcomes were recorded. Peripheral blood samples were collected prior to and on completion of plasma therapy and the following additional parameters were assessed at both time points: activity of the von Willebrand factor (VWF) cleaving protease, a-disintegrin-and-metalloproteinase-with-thrombospondin-motifs 13 (ADAMTS-13) and the presence of ADAMTS-13 autoantibodies, levels of pro-inflammatory cytokines, interleukin-6 and tumour necrosis factor-alpha, and two endothelial cell adhesion molecules. Complement activation was assessed by sequential measurement of C3 and C4 as well as levels of the complement inhibitor, factor H. RESULTS: The inflammatory and endothelial activation markers were significantly ( P  < 0.001) elevated in the cohort of patients prior to plasma therapy compared with levels on discharge. Complement was activated and normalized with therapy. The ADAMTS-13 levels were reduced with significant auto-antibodies to this protease at presentation. CONCLUSION: Inflammation in HIV mediates endothelial damage and complement activation. This study proposes that these processes are probably contributory to the development of HIV-TTP, which can therefore be characterized in part as a complementopathy, resembling TTP-like syndrome.


Assuntos
Infecções por HIV , Púrpura Trombocitopênica Trombótica , Proteína ADAMTS13 , Estudos de Coortes , Infecções por HIV/complicações , Humanos , Inflamação , Metaloendopeptidases/metabolismo , Estudos Prospectivos , Púrpura Trombocitopênica Trombótica/complicações , Púrpura Trombocitopênica Trombótica/terapia , África do Sul , Fator de von Willebrand
15.
Methods Mol Biol ; 2511: 133-147, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35838957

RESUMO

SARS-CoV-2 causes generally mild symptoms, with approximately 10-20% of cases progressing to severe disease. The pathophysiologic mechanisms by which SARS-CoV-2 causes severe disease are largely unknown. Data have indicated the involvement of different immunogenetic markers such as HLA, T, and B cells, to be associated with disease outcome. This has led to interest in these genes as potential biomarkers of SARS-CoV-2 susceptibility and for predicting prognosis and response to vaccines and other therapeutic strategies. In this chapter, we discussed outline protocols for characterizing these potential biomarkers and methods for identifying SARS-CoV-2 biomarkers using the Luminex® 100/200 technology and next-generation sequencing.


Assuntos
COVID-19 , SARS-CoV-2 , Biomarcadores , COVID-19/diagnóstico , Sequenciamento de Nucleotídeos em Larga Escala , Humanos , Imunogenética , SARS-CoV-2/genética
16.
Methods Mol Biol ; 2511: 307-319, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35838970

RESUMO

Severe acute respiratory syndrome-coronavirus 2 (SARS-CoV-2) has been identified as the causative agent of COVID-19. Accurate detection of SARS-CoV-2 infection is not only important for management of infected individuals but also to break the chain of transmission. Although the polymerase chain reaction (PCR) is the gold standard for diagnosis of acute SARS-CoV-2 infection, there are a number of limitations of these assays, which include the inability to detect past infection and decline in sensitivity 14 days post-symptom onset. There are several serology tests developed for the detection of SARS-CoV-2 antibodies including high-throughput serology platforms and lateral flow immunoassays. These tests should be evaluated for their performance to meet local regulations acceptance criteria. To optimize the diagnostic algorithm for SARS-CoV-2, this protocol describes the evaluation of serological antibody testing using various automated serology platforms and lateral flow immunoassays. This protocol was evaluated in both serum and plasma samples. The sample preparation, procedure, and data analysis are described. The protocol can be adapted for any serological testing.


Assuntos
COVID-19 , SARS-CoV-2 , Anticorpos Antivirais , COVID-19/diagnóstico , Teste para COVID-19 , Humanos , Imunoensaio/métodos , Sensibilidade e Especificidade
17.
PLoS One ; 17(2): e0262442, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35120133

RESUMO

In late December 2019, pneumonia cases of unknown origin were reported in Wuhan, China. This virus was named SARS-CoV2 and the clinical syndrome was named coronavirus disease 19 (COVID-19). South Africa, despite strict and early lockdown has the highest infection rate in Africa. A key component of South Africa's response to SARSCoV2 was the rapid scale-up of diagnostic testing. The Abbott SARS-CoV2 assay detects IgG antibodies against the Nucleocapsid (N) protein of the SARS-CoV2 virus. This study undertook to validate and evaluate performance criteria of the Abbott assay and to establish whether this assay would show clinical utility in our population. Positive patients (n = 391) and negative controls (n = 139) were included. The Architect-i and Alinity-i systems were analyzers that were used to perform the SARS-CoV-2 IgG assay. In-house ELISA was incorporated into the study as a confirmatory serology test. A total of number of 530 participants was tested, 87% were symptomatic with infection and 13% were asymptomatic. When compared to RT-qPCR, the sensitivity of Architect and Alinity SARS-CoV2 assays was 69.5% and 64.8%, respectively. Specificity for Architect and Alinity assays was 95% and 90.3%, respectively. The Abbott assay was also compared to in house ELISA assay, with sensitivity for the Architect and Alinity assays of 94.7% and 92.5%, respectively. Specificity for Abbott Alinity assays was 91.7% higher than Abbott Architect 88.1%. Based on the current findings testing of IgG after 14 days is recommended in South Africa and supports other studies performed around the world.


Assuntos
Anticorpos Antivirais/sangue , Teste Sorológico para COVID-19/métodos , COVID-19/diagnóstico , Imunoglobulina G/sangue , SARS-CoV-2/isolamento & purificação , Adulto , Idoso , Idoso de 80 Anos ou mais , Anticorpos Antivirais/imunologia , COVID-19/sangue , COVID-19/epidemiologia , COVID-19/virologia , Ensaio de Imunoadsorção Enzimática , Feminino , Seguimentos , Humanos , Imunoglobulina G/imunologia , Masculino , Pessoa de Meia-Idade , Prognóstico , Estudos Retrospectivos , África do Sul/epidemiologia , Adulto Jovem
18.
J Immunol Methods ; 496: 113096, 2021 09.
Artigo em Inglês | MEDLINE | ID: mdl-34242653

RESUMO

Serology or antibody tests for COVID-19 are designed to detect antibodies (mainly Immunoglobulin M (IgM) and Immunoglobulin G (IgG) produced in response to Severe Acute Respiratory Syndrome Coronavirus 2 (SARS CoV-2) infection. In this study, 30 lateral flow immunoassays were tested using serum or plasma from patients with confirmed SARS CoV-2 infection. Negative serological controls were accessed from a well-characterised bank of sera which were stored prior to February 2020. Operational characteristics and ease of use of the assays are reported. 4/30 (13%) of kits (Zheihang Orient Gene COVID-19 IgG/IgM, Genrui Novel Coronavirus (2019-nCoV) IgG/IgM, Biosynex COVID-19 BSS IgG/IgM, Boson Biotech 2019-nCoV IgG/IgM) were recommended for SAHPRA approval based on kit sensitivity. Of these, only the Orientgene was recommended by SAHPRA in August 2020 for use within the approved national testing algorithm while the remaining three received limited authorization for evaluation. All kits evaluated work on the same basic principle of immunochromatography with minor differences noted in the shape and colour of cartridges, the amount of specimen volume required and the test duration. Performance of the lateral flow tests were similar to sensitivities and specificities reported in other studies. The cassettes of the majority of kits evaluated (90%) detected both IgG and IgM. Only 23% of kits evaluated contained all consumables required for point-of-care testing. The study highlights the need for thorough investigation of kits prior to implementation.


Assuntos
Anticorpos Antivirais/isolamento & purificação , Teste Sorológico para COVID-19/instrumentação , COVID-19/diagnóstico , Imunoensaio/instrumentação , Kit de Reagentes para Diagnóstico/estatística & dados numéricos , Anticorpos Antivirais/sangue , Anticorpos Antivirais/imunologia , COVID-19/sangue , COVID-19/imunologia , COVID-19/virologia , Teste de Ácido Nucleico para COVID-19/estatística & dados numéricos , Teste Sorológico para COVID-19/estatística & dados numéricos , Humanos , Imunoensaio/estatística & dados numéricos , Imunoglobulina G/sangue , Imunoglobulina G/imunologia , Imunoglobulina G/isolamento & purificação , Imunoglobulina M/sangue , Imunoglobulina M/imunologia , Imunoglobulina M/isolamento & purificação , Testes Imediatos/estatística & dados numéricos , RNA Viral/sangue , RNA Viral/isolamento & purificação , SARS-CoV-2/genética , SARS-CoV-2/imunologia , SARS-CoV-2/isolamento & purificação , Sensibilidade e Especificidade
19.
PLoS One ; 16(6): e0252317, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34161348

RESUMO

Severe Acute Respiratory Syndrome-Coronavirus 2 (SARS-CoV-2) has been identified as the causative agent for causing the clinical syndrome of COVID -19. Accurate detection of SARS-CoV-2 infection is not only important for management of infected individuals but also to break the chain of transmission. South Africa is the current epicenter of SARS-CoV-2 infection in Africa. To optimize the diagnostic algorithm for SARS-CoV-2 in the South African setting, the study aims to evaluate the diagnostic performance of the EUROIMMUN Anti-SARS-CoV-2 assays. This study reported the performance of EUROIMMUN enzyme-linked immunosorbent assay (ELISA) for semi-quantitative detection of IgA and IgG antibodies in serum and plasma samples targeting the recombinant S1 domain of the SARS-CoV-2 spike protein as antigen. Samples were collected from 391 individuals who had tested positive for SARS-CoV-2 and 139 SARS CoV-2 negative controls. Samples were stratified by number of days' post-PCR diagnosis and symptoms. The sensitivity of EUROIMMUN IgG was 64.1% (95% CI: 59.1-69.0%) and 74.3% (95% CI: 69.6-78.6%) for IgA and the specificity was lower for IgA [84.2% (95% CI: 77-89.2%)] than IgG [95.2% (95% CI: 90.8-98.4%)]. The EUROIMMUN Anti-SARS-CoV-2 ELISA Assay sensitivity was higher for IgA but low for IgG and improved for both assays in symptomatic individuals and at later timepoints post PCR diagnosis.


Assuntos
Teste Sorológico para COVID-19/métodos , Imunoglobulina A/sangue , Imunoglobulina G/sangue , Adulto , Idoso , Idoso de 80 Anos ou mais , Teste de Ácido Nucleico para COVID-19/métodos , Ensaio de Imunoadsorção Enzimática/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Testes Imediatos , Sensibilidade e Especificidade , África do Sul
20.
Front Plant Sci ; 12: 589940, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33868324

RESUMO

Background: The severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) pandemic has swept the world and poses a significant global threat to lives and livelihoods, with 115 million confirmed cases and at least 2.5 million deaths from Coronavirus disease 2019 (COVID-19) in the first year of the pandemic. Developing tools to measure seroprevalence and understand protective immunity to SARS-CoV-2 is a priority. We aimed to develop a serological assay using plant-derived recombinant viral proteins, which represent important tools in less-resourced settings. Methods: We established an indirect ELISA using the S1 and receptor-binding domain (RBD) portions of the spike protein from SARS-CoV-2, expressed in Nicotiana benthamiana. We measured antibody responses in sera from South African patients (n = 77) who had tested positive by PCR for SARS-CoV-2. Samples were taken a median of 6 weeks after the diagnosis, and the majority of participants had mild and moderate COVID-19 disease. In addition, we tested the reactivity of pre-pandemic plasma (n = 58) and compared the performance of our in-house ELISA with a commercial assay. We also determined whether our assay could detect SARS-CoV-2-specific IgG and IgA in saliva. Results: We demonstrate that SARS-CoV-2-specific immunoglobulins are readily detectable using recombinant plant-derived viral proteins, in patients who tested positive for SARS-CoV-2 by PCR. Reactivity to S1 and RBD was detected in 51 (66%) and 48 (62%) of participants, respectively. Notably, we detected 100% of samples identified as having S1-specific antibodies by a validated, high sensitivity commercial ELISA, and optical density (OD) values were strongly and significantly correlated between the two assays. For the pre-pandemic plasma, 1/58 (1.7%) of samples were positive, indicating a high specificity for SARS-CoV-2 in our ELISA. SARS-CoV-2-specific IgG correlated significantly with IgA and IgM responses. Endpoint titers of S1- and RBD-specific immunoglobulins ranged from 1:50 to 1:3,200. S1-specific IgG and IgA were found in saliva samples from convalescent volunteers. Conclusion: We demonstrate that recombinant SARS-CoV-2 proteins produced in plants enable robust detection of SARS-CoV-2 humoral responses. This assay can be used for seroepidemiological studies and to measure the strength and durability of antibody responses to SARS-CoV-2 in infected patients in our setting.

SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa