Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 116
Filtrar
1.
Radiol Med ; 2024 Jun 27.
Artigo em Inglês | MEDLINE | ID: mdl-38935247

RESUMO

PURPOSE: To determine the optimal window setting for virtual monoenergetic images (VMI) reconstructed from dual-layer spectral coronary computed tomography angiography (DE-CCTA) datasets. MATERIAL AND METHODS: 50 patients (30 males; mean age 61.1 ± 12.4 years who underwent DE-CCTA from May 2021 to June 2022 for suspected coronary artery disease, were retrospectively included. Image quality assessment was performed on conventional images and VMI reconstructions at 70 and 40 keV. Objective image quality was assessed using contrast-to-noise ratio (CNR). Two independent observers manually identified the best window settings (B-W/L) for VMI 70 and VMI 40 visualization. B-W/L were then normalized with aortic attenuation using linear regression analysis to obtain the optimized W/L (O-W/L) settings. Additionally, subjective image quality was evaluated using a 5-point Likert scale, and vessel diameters were measured to examine any potential impact of different W/L settings. RESULTS: VMI 40 demonstrated higher CNR values compared to conventional and VMI 70. B-W/L settings identified were 1180/280 HU for VMI 70 and 3290/900 HU for VMI 40. Subsequent linear regression analysis yielded O-W/L settings of 1155/270 HU for VMI 70 and 3230/880 HU for VMI 40. VMI 40 O-W/L received the highest scores for each parameter compared to conventional (all p < 0.0027). Using O-W/L settings for VMI 70 and VMI 40 did not result in significant differences in vessel measurements compared to conventional images. CONCLUSION: Optimization of VMI requires adjustments in W/L settings. Our results recommend W/L settings of 1155/270 HU for VMI 70 and 3230/880 HU for VMI 40.

2.
Eur Radiol ; 33(9): 6339-6350, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37000215

RESUMO

OBJECTIVES: The purpose of this study was to evaluate the diagnostic accuracy of third-generation dual-source dual-energy CT (DECT) color-coded collagen reconstructions for the assessment of the cruciate ligaments compared to standard grayscale image reconstruction. METHODS: Patients who underwent third-generation dual-source DECT followed by either 3-T MRI or arthroscopy of the knee joint within 14 days between January 2016 and December 2021 were included in this retrospective study. Five radiologists independently evaluated conventional grayscale DECT for the presence of injury to the cruciate ligaments; after 4 weeks, readers re-evaluated the examinations using grayscale images and color-coded collagen reconstructions. A reference standard for MRI was provided by a consensus reading of two experienced readers and arthroscopy. Sensitivity and specificity were the primary metrics of diagnostic performance. RESULTS: Eighty-five patients (mean age, 44 years ± 16; 50 male) with injury to the ACL or PCL (n = 31) were ultimately included. Color-coded collagen reconstructions significantly increased overall sensitivity (94/105 [90%] vs. 67/105 [64%]), specificity (248/320 [78%] vs. 215/320 [67%]), PPV (94/166 [57%] vs. 67/162 [39%]), NPV (248/259 [96%] vs. 215/253 [85%]), and accuracy (342/425 [81%] vs. 282/425 [66%]) for the detection of injury to the anterior cruciate ligament (all parameters, p < .001). For injury to the posterior cruciate ligament, diagnostic accuracy increased for complete tears (p < .001). Color-coded collagen reconstructions achieved superior diagnostic confidence, image quality, and noise scores compared to grayscale CT (all parameters, p < .001) and showed good agreement with MRI examinations. CONCLUSIONS: DECT-derived color-coded collagen reconstructions yield substantially higher diagnostic accuracy and confidence for assessing the integrity of the cruciate ligaments compared to standard grayscale CT in patients with acute trauma. KEY POINTS: • Color-coded collagen reconstructions derived from dual-energy CT yield substantially higher diagnostic accuracy and confidence for the assessment of the cruciate ligaments compared to standard grayscale CT in patients with acute trauma. • Color-coded collagen reconstructions demonstrate good agreement with MRI for the assessment cruciate ligament injury. • Dual-energy CT may serve as a readily available screening approach for patients with acute trauma to the knee when injury to the cruciate ligaments is suspected.


Assuntos
Lesões do Ligamento Cruzado Anterior , Tomografia Computadorizada por Raios X , Humanos , Masculino , Adulto , Estudos Retrospectivos , Tomografia Computadorizada por Raios X/métodos , Articulação do Joelho , Ligamento Cruzado Anterior , Colágeno , Lesões do Ligamento Cruzado Anterior/diagnóstico por imagem , Sensibilidade e Especificidade , Imageamento por Ressonância Magnética/métodos
3.
Radiol Med ; 128(1): 16-26, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-36583843

RESUMO

BACKGROUND: The aim of the study was to provide radiologists and clinicians a rapid tool for assessment of intestinal inflammation in Crohn's disease (CD) patients through quantification of diffusion-weighted imaging (DWI) signal intensity while performing magnetic resonance enterography (MRE). MATERIALS AND METHODS: A monocentric retrospective study was conducted between September 2018 and July 2021 on CD patients who underwent MRE. Two radiologists measured signal intensity on DWI scans at the highest b-value (800 s/mm2) within pathologic intestinal walls, lymph nodes, spleen and psoas muscle and calculated the relative ratios. Spearman, Mann-Whitney and Jonckheere-Terpstra tests were applied for estimating correlation among ratios, significant differences between the two patient groups and determining the trend in relation to endoscopic classes. Wilcoxon's and Cronbach's alpha tests were employed for comparison of DWI measurements and ratios between the two observers. RESULTS: Fifty-nine patients were enrolled in the study. In the non-surgical group, correlation has been found among Simple Endoscopic Score for Crohn's Disease (SES-CD) classes and the different ratios: bowel/spleen (p = 0.034), bowel/psoas (p = 0.008) and bowel/lymph node (p = 0.010). Within the surgical group, positive correlation was found only between bowel/lymph node ratio and bowel/psoas ratio (p = 0.014). The J-T test demonstrated an increasing monotonic trend for bowel/psoas ratio and bowel/lymph node ratio and SES-CD classes. Inter-reader evaluation demonstrated no statistical differences for DWI measurements and high degree of concordance for the final ratios. CONCLUSION: DWI ratios correlate with endoscopic classes in non-surgical patients and have inter-observer reproducibility.


Assuntos
Doença de Crohn , Humanos , Doença de Crohn/diagnóstico por imagem , Doença de Crohn/patologia , Estudos Retrospectivos , Reprodutibilidade dos Testes , Imagem de Difusão por Ressonância Magnética/métodos , Imageamento por Ressonância Magnética/métodos , Espectroscopia de Ressonância Magnética
4.
Radiol Med ; 128(8): 891-899, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-37310558

RESUMO

PURPOSE: To compare conventional CT images and virtual monoenergetic images (VMI) at dual-layer dual-energy CT (dlDECT) in patients with colorectal cancer (CRC) through quantitative analysis and to investigate the added value of VMI. MATERIAL AND METHODS: Sixty-six consecutive patients with histologically documented CRC and available VMI reconstructions were retrospectively investigated. Subsequently, forty-two patients, without any colonic disease at colonoscopy, were selected as control group. Conventional CT images and VMI reconstructions at energy levels ranging from 40 (VMI40) to 100 keV (VMI100) in 10 keV increments, were obtained from the late arterial phase. First, signal-to-noise (SNR) and contrast-to-noise (CNR) ratios were obtained to select the best VMI reconstruction. Finally, the diagnostic accuracy of conventional CT and VMI40 in late arterial phase was evaluated. RESULTS: On quantitative analysis, SNR and CNR were higher for VMI40 (19.5 ± 7.7 and 11.8 ± 6.2, respectively) with statistically significant differences compared to conventional CT (P < 0.05) and all the other VMI reconstructions (P < 0.05), except for VMI50 (P > 0.05). The addition of VMI40 to conventional CT images significantly improved the area under the curve (AUC) for the diagnosis of CRC, increasing it from 0.875 to 0.943 for reader 1 (P < 0.05) and from 0.916 to 0.954 for reader 2 (P < 0.05). The improvement was greater in the less experienced radiologist (0.068) compared to the more experienced one (0.037). CONCLUSION: VMI40 has showed the highest quantitative image parameters. Furthermore, the use of VMI40 can lead to a significant improvement in the diagnostic performance for detecting CRC.


Assuntos
Neoplasias Colorretais , Imagem Radiográfica a Partir de Emissão de Duplo Fóton , Humanos , Tomografia Computadorizada por Raios X/métodos , Estudos Retrospectivos , Razão Sinal-Ruído , Imagem Radiográfica a Partir de Emissão de Duplo Fóton/métodos , Neoplasias Colorretais/diagnóstico por imagem , Interpretação de Imagem Radiográfica Assistida por Computador/métodos
5.
Eur Radiol ; 32(1): 561-571, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-34215940

RESUMO

OBJECTIVES: To compare dual-energy CT (DECT) and MRI for assessing presence and extent of traumatic bone marrow edema (BME) and fracture line depiction in acute vertebral fractures. METHODS: Eighty-eight consecutive patients who underwent dual-source DECT and 3-T MRI of the spine were retrospectively analyzed. Five radiologists assessed all vertebrae for presence and extent of BME and for identification of acute fracture lines on MRI and, after 12 weeks, on DECT series. Additionally, image quality, image noise, and diagnostic confidence for overall diagnosis of acute vertebral fracture were assessed. Quantitative analysis of CT numbers was performed by a sixth radiologist. Two radiologists analyzed MRI and grayscale DECT series to define the reference standard. RESULTS: For assessing BME presence and extent, DECT showed high sensitivity (89% and 84%, respectively) and specificity (98% in both), and similarly high diagnostic confidence compared to MRI (2.30 vs. 2.32; range 0-3) for the detection of BME (p = .72). For evaluating acute fracture lines, MRI achieved high specificity (95%), moderate sensitivity (76%), and a significantly lower diagnostic confidence compared to DECT (2.42 vs. 2.62, range 0-3) (p < .001). A cutoff value of - 0.43 HU provided a sensitivity of 89% and a specificity of 90% for diagnosing BME, with an overall AUC of 0.96. CONCLUSIONS: DECT and MRI provide high diagnostic confidence and image quality for assessing acute vertebral fractures. While DECT achieved high overall diagnostic accuracy in the analysis of BME presence and extent, MRI provided moderate sensitivity and lower confidence for evaluating fracture lines. KEY POINTS: • In the setting of spinal trauma, dual-energy CT (DECT) is highly accurate in the evaluation of acute vertebral fractures and bone marrow edema presence and extent. • MRI provides moderate sensitivity and lower diagnostic confidence for the depiction of acute fracture lines, when compared to DECT, which might result in potentially inaccurate and underestimated severity assessment of injuries in certain cases when no fracture lines are visible on MRI. • DECT may represent a valid imaging alternative to MRI in specific settings of acute spinal trauma and in follow-up examinations, especially in elderly or unstable patients and in cases of subtle or complex orientated fracture lines.


Assuntos
Fraturas da Coluna Vertebral , Idoso , Medula Óssea , Edema/diagnóstico por imagem , Humanos , Imageamento por Ressonância Magnética , Estudos Retrospectivos , Sensibilidade e Especificidade , Fraturas da Coluna Vertebral/diagnóstico por imagem , Tomografia Computadorizada por Raios X
6.
Eur Radiol ; 32(5): 3076-3084, 2022 May.
Artigo em Inglês | MEDLINE | ID: mdl-34713330

RESUMO

OBJECTIVES: To evaluate the predictive value of volumetric bone mineral density (BMD) assessment of the lumbar spine derived from phantomless dual-energy CT (DECT)-based volumetric material decomposition as an indicator for the 2-year occurrence risk of osteoporosis-associated fractures. METHODS: L1 of 92 patients (46 men, 46 women; mean age, 64 years, range, 19-103 years) who had undergone third-generation dual-source DECT between 01/2016 and 12/2018 was retrospectively analyzed. For phantomless BMD assessment, dedicated DECT postprocessing software using material decomposition was applied. Digital files of all patients were sighted for 2 years following DECT to obtain the incidence of osteoporotic fractures. Receiver operating characteristic (ROC) analysis was used to calculate cut-off values and logistic regression models were used to determine associations of BMD, sex, and age with the occurrence of osteoporotic fractures. RESULTS: A DECT-derived BMD cut-off of 93.70 mg/cm3 yielded 85.45% sensitivity and 89.19% specificity for the prediction to sustain one or more osteoporosis-associated fractures within 2 years after BMD measurement. DECT-derived BMD was significantly associated with the occurrence of new fractures (odds ratio of 0.8710, 95% CI, 0.091-0.9375, p < .001), indicating a protective effect of increased DECT-derived BMD values. Overall AUC was 0.9373 (CI, 0.867-0.977, p < .001) for the differentiation of patients who sustained osteoporosis-associated fractures within 2 years of BMD assessment. CONCLUSIONS: Retrospective DECT-based volumetric BMD assessment can accurately predict the 2-year risk to sustain an osteoporosis-associated fracture in at-risk patients without requiring a calibration phantom. Lower DECT-based BMD values are strongly associated with an increased risk to sustain fragility fractures. KEY POINTS: •Dual-energy CT-derived assessment of bone mineral density can identify patients at risk to sustain osteoporosis-associated fractures with a sensitivity of 85.45% and a specificity of 89.19%. •The DECT-derived BMD threshold for identification of at-risk patients lies above the American College of Radiology (ACR) QCT guidelines for the identification of osteoporosis (93.70 mg/cm3 vs 80 mg/cm3).


Assuntos
Osteoporose , Fraturas por Osteoporose , Absorciometria de Fóton , Adulto , Idoso , Idoso de 80 Anos ou mais , Densidade Óssea , Feminino , Humanos , Vértebras Lombares/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Osteoporose/complicações , Osteoporose/diagnóstico por imagem , Osteoporose/epidemiologia , Fraturas por Osteoporose/diagnóstico por imagem , Fraturas por Osteoporose/epidemiologia , Estudos Retrospectivos , Tomografia Computadorizada por Raios X , Adulto Jovem
7.
Eur Radiol ; 32(4): 2168-2177, 2022 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-34820684

RESUMO

OBJECTIVES: To investigate the diagnostic accuracy of color-coded contrast-enhanced dual-energy CT virtual noncalcium (VNCa) reconstructions for the assessment of lumbar disk herniation compared to unenhanced VNCa imaging. METHODS: A total of 91 patients were retrospectively evaluated (65 years ± 16; 43 women) who had undergone third-generation dual-source dual-energy CT and 3.0-T MRI within an examination interval up to 3 weeks between November 2019 and December 2020. Eight weeks after assessing unenhanced color-coded VNCa reconstructions for the presence and degree of lumbar disk herniation, corresponding contrast-enhanced portal venous phase color-coded VNCa reconstructions were independently analyzed by the same five radiologists. MRI series were additionally analyzed by one highly experienced musculoskeletal radiologist and served as reference standard. RESULTS: MRI depicted 210 herniated lumbar disks in 91 patients. VNCa reconstructions derived from contrast-enhanced CT scans showed similar high overall sensitivity (93% vs 95%), specificity (94% vs 95%), and accuracy (94% vs 95%) for the assessment of lumbar disk herniation compared to unenhanced VNCa images (all p > .05). Interrater agreement in VNCa imaging was excellent for both, unenhanced and contrast-enhanced CT (κ = 0.84 vs κ = 0.86; p > .05). Moreover, ratings for diagnostic confidence, image quality, and noise differed not significantly between unenhanced and contrast-enhanced VNCa series (all p > .05). CONCLUSIONS: Color-coded VNCa reconstructions derived from contrast-enhanced dual-energy CT yield similar diagnostic accuracy for the depiction of lumbar disk herniation compared to unenhanced VNCa imaging and therefore may improve opportunistic retrospective lumbar disk herniation assessment, particularly in case of staging CT examinations. KEY POINTS: • Color-coded dual-source dual-energy CT virtual noncalcium (VNCa) reconstructions derived from portal venous phase yield similar high diagnostic accuracy for the assessment of lumbar disk herniation compared to unenhanced VNCa CT series (94% vs 95%) with MRI serving as a standard of reference. • Diagnostic confidence, image quality, and noise levels differ not significantly between unenhanced and contrast-enhanced portal venous phase VNCa dual-energy CT series. • Dual-source dual-energy CT might have the potential to improve opportunistic retrospective lumbar disk herniation assessment in CT examinations performed for other indications through reconstruction of VNCa images.


Assuntos
Deslocamento do Disco Intervertebral , Imagem Radiográfica a Partir de Emissão de Duplo Fóton , Medula Óssea , Edema , Feminino , Humanos , Deslocamento do Disco Intervertebral/diagnóstico por imagem , Estudos Retrospectivos , Sensibilidade e Especificidade , Tomografia Computadorizada por Raios X/métodos
8.
J Clin Ultrasound ; 50(9): 1414-1431, 2022 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-36069404

RESUMO

Artificial intelligence is rapidly expanding in all technological fields. The medical field, and especially diagnostic imaging, has been showing the highest developmental potential. Artificial intelligence aims at human intelligence simulation through the management of complex problems. This review describes the technical background of artificial intelligence, machine learning, and deep learning. The first section illustrates the general potential of artificial intelligence applications in the context of request management, data acquisition, image reconstruction, archiving, and communication systems. In the second section, the prospective of dedicated tools for segmentation, lesion detection, automatic diagnosis, and classification of musculoskeletal disorders is discussed.


Assuntos
Aprendizado Profundo , Sistema Musculoesquelético , Humanos , Inteligência Artificial , Aprendizado de Máquina , Processamento de Imagem Assistida por Computador , Sistema Musculoesquelético/diagnóstico por imagem
9.
Eur Radiol ; 31(7): 4428-4437, 2021 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-33409799

RESUMO

OBJECTIVES: To investigate the diagnostic accuracy of color-coded dual-energy CT virtual non-calcium (VNCa) reconstructions for the assessment of bone marrow edema (BME) of the scaphoid in patients with acute wrist trauma. METHODS: Our retrospective study included data from 141 patients (67 women, 74 men; mean age 43 years, range 19-80 years) with acute wrist trauma who had undergone third-generation dual-source dual-energy CT and 3-T MRI within 7 days. Eight weeks after assessment of conventional grayscale dual-energy CT scans for the presence of fractures, corresponding color-coded VNCa reconstructions were independently analyzed by the same six radiologists for the presence of BME. CT numbers on VNCa reconstructions were evaluated by a seventh radiologist. Consensus reading of MRI series by two additional radiologists served as the reference standard. RESULTS: MRI depicted 103 scaphoideal zones with BME in 76 patients. On qualitative analysis, VNCa images yielded high overall sensitivity (580/618 [94%]), specificity (1880/1920 [98%]), and accuracy (2460/2538 [97%]) for assessing BME as compared with MRI as reference standard. The interobserver agreement was excellent (κ = 0.98). CT numbers derived from VNCa images were significantly different in zones with and without edema (p < 0.001). A cutoff value of - 46 Hounsfield units provided a sensitivity of 91% and specificity of 97% for differentiating edematous scaphoid lesions. Receiver operating characteristic curve analysis revealed an overall area under the curve of 0.98. CONCLUSIONS: Qualitative and quantitative analyses showed excellent diagnostic accuracy of color-coded VNCa reconstructions for assessing traumatic BME of the scaphoid compared to MRI. KEY POINTS: • Color-coded virtual non-calcium (VNCa) reconstructions yield excellent diagnostic accuracy in assessing bone marrow edema of the scaphoid. • VNCa imaging enables detection of non-displaced fractures that are occult on standard grayscale CT. • Diagnostic confidence is comparable between VNCa imaging and MRI.


Assuntos
Medula Óssea , Osso Escafoide , Adulto , Idoso , Idoso de 80 Anos ou mais , Medula Óssea/diagnóstico por imagem , Cálcio , Edema/diagnóstico por imagem , Feminino , Humanos , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Osso Escafoide/diagnóstico por imagem , Sensibilidade e Especificidade , Tomografia Computadorizada por Raios X , Adulto Jovem
10.
Eur Radiol ; 31(12): 9221-9231, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-34076743

RESUMO

OBJECTIVES: To determine the diagnostic accuracy of dual-energy CT (DECT) virtual noncalcium (VNCa) reconstructions for assessing thoracic disk herniation compared to standard grayscale CT. METHODS: In this retrospective study, 87 patients (1131 intervertebral disks; mean age, 66 years; 47 women) who underwent third-generation dual-source DECT and 3.0-T MRI within 3 weeks between November 2016 and April 2020 were included. Five blinded radiologists analyzed standard DECT and color-coded VNCa images after a time interval of 8 weeks for the presence and degree of thoracic disk herniation and spinal nerve root impingement. Consensus reading of independently evaluated MRI series served as the reference standard, assessed by two separate experienced readers. Additionally, image ratings were carried out by using 5-point Likert scales. RESULTS: MRI revealed a total of 133 herniated thoracic disks. Color-coded VNCa images yielded higher overall sensitivity (624/665 [94%; 95% CI, 0.89-0.96] vs 485/665 [73%; 95% CI, 0.67-0.80]), specificity (4775/4990 [96%; 95% CI, 0.90-0.98] vs 4066/4990 [82%; 95% CI, 0.79-0.84]), and accuracy (5399/5655 [96%; 95% CI, 0.93-0.98] vs 4551/5655 [81%; 95% CI, 0.74-0.86]) for the assessment of thoracic disk herniation compared to standard CT (all p < .001). Interrater agreement was excellent for VNCa and fair for standard CT (ϰ = 0.82 vs 0.37; p < .001). In addition, VNCa imaging achieved higher scores regarding diagnostic confidence, image quality, and noise compared to standard CT (all p < .001). CONCLUSIONS: Color-coded VNCa imaging yielded substantially higher diagnostic accuracy and confidence for assessing thoracic disk herniation compared to standard CT. KEY POINTS: • Color-coded VNCa reconstructions derived from third-generation dual-source dual-energy CT yielded significantly higher diagnostic accuracy for the assessment of thoracic disk herniation and spinal nerve root impingement compared to standard grayscale CT. • VNCa imaging provided higher diagnostic confidence and image quality at lower noise levels compared to standard grayscale CT. • Color-coded VNCa images may potentially serve as a viable imaging alternative to MRI under circumstances where MRI is unavailable or contraindicated.


Assuntos
Imagem Radiográfica a Partir de Emissão de Duplo Fóton , Tomografia Computadorizada por Raios X , Idoso , Medula Óssea , Edema , Feminino , Humanos , Estudos Retrospectivos , Sensibilidade e Especificidade
11.
Radiol Med ; 126(6): 761-767, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-33715036

RESUMO

OBJECTIVE: Fractional extracellular space has been validated as a marker of hepatic fibrotic in cirrhotic patients at CT-scan as well as on dual-energy CT, which takes advantage from iodine uptake. Since no consensus still exists between equilibrium phases performed at 3 or 10 min, the first aim of this work is to evaluate performances at the two different time points. Moreover, correlation between fractional extracellular space and oesophageal varices, directly related to liver fibrosis, has been assessed. MATERIALS AND METHODS: Dual-Energy equilibrium phases at 3 and 10 min were performed within a follow-up CT-protocol scan in cirrhotic patients. Oesophageal varices were endoscopically assessed according to their size. At the two different time points, correlation between iodine density of the right and left liver lobes and correlation between the fractional extracellular space values were assessed. Correlation between fractional extracellular space and endoscopic grade of oesophageal varices was calculated. RESULTS: No statistical differences were found between the iodine density values from the two liver lobes at the two time points (p = 0.8 at 3'; p = 0.5 at 10'). No statistical difference about fractional extracellular space estimation was found between the two time points (p = 0.17). Correlation between fractional extracellular space values and oesophageal varices was moderate (ρ = 0.45, IC 0.08-0.71, p < 0.05). CONCLUSION: Fractional extracellular space assessed on dual-energy CT at equilibrium phases with different timing was substantially similar. The moderate correlation found between fractional extracellular space and endoscopic grade of oesophageal varices confirms that CT-scan is not currently reliable as endoscopy.


Assuntos
Varizes Esofágicas e Gástricas/diagnóstico , Espaço Extracelular/diagnóstico por imagem , Cirrose Hepática/complicações , Fígado/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Idoso , Idoso de 80 Anos ou mais , Varizes Esofágicas e Gástricas/etiologia , Feminino , Seguimentos , Humanos , Cirrose Hepática/diagnóstico , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Curva ROC
12.
Radiol Med ; 126(7): 901-909, 2021 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-33954899

RESUMO

Vesicoureteral reflux (VUR) is a pathological condition contradistinguished by monolateral or bilateral retrograde flow of urine from the bladder to the ureter and to the kidney. If not properly recognized and treated, VUR can potentially be associated to several complications such as recurrent infections and possible secondary scars with Chronic Kidney Disease (CKD). Furthermore, it represents an important risk factor for nephrovascular hypertension. During the last 20 years, the diagnostic approach to this entity has passed through several, drastic changes: indeed, since its introduction in 1994 contrast-enhanced voiding urosonography (ceVUS) has gradually accompanied the voiding cystourethrography (VCUG) as alternative imaging technique for the diagnosis and staging of VUR. Despite a large number of papers has strongly encouraged its use in clinical practice, due to the lack of ionizing radiations and its high sensitivity rate, to date almost all the guidelines only include the VCUG for VUR diagnosis. The introduction of technologically advanced US software and the approval of the intravesical administration of ultrasound contrast agents by the Food and Drug Administration (FDA) and by the European Medicine Agency (EMA) have to induce the Scientific Community to a deep revaluation of the role of ceVUS in the diagnosis and follow-up of VUR: urosonography might extensively replace VCUG as the reference method, reserving to cystourethrography a role in the most complex anatomic settings for pre-surgical evaluation.


Assuntos
Meios de Contraste/intoxicação , Ultrassonografia/métodos , Bexiga Urinária/diagnóstico por imagem , Micção/fisiologia , Refluxo Vesicoureteral/diagnóstico , Humanos , Bexiga Urinária/fisiopatologia , Refluxo Vesicoureteral/fisiopatologia
13.
Radiol Med ; 125(4): 384-397, 2020 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-31925704

RESUMO

Unlike conventional computed tomography, dual-energy computed tomography is a relatively novel technique that exploits ionizing radiations at different energy levels. The separate radiation sets can be achieved through different technologies, such as dual source, dual layers or rapid switching voltage. Body tissue molecules vary for their specific atomic numbers and electron density, and the interaction with different sets of radiations results in different attenuations, allowing to their final distinction. In particular, iodine recognition and quantification have led to important information about intravenous contrast medium delivery within the body. Over the years, useful post-processing algorithms have also been validated for improving tissue characterization. For instance, contrast resolution improvement and metal artifact reduction can be obtained through virtual monoenergetic images, dose reduction by virtual non-contrast reconstructions and iodine distribution highlighting through iodine overlay maps. Beyond the evaluation of the abdominal organs, dual-energy computed tomography has also been successfully employed in other anatomical districts. Although lung perfusion is one of the most investigated, this evaluation has been extended to narrowly fields of application, such as musculoskeletal, head and neck, vascular and cardiac. The potential pool of information provided by dual-energy technology is already wide and not completely explored, yet. Therefore, its performance continues to raise increasing interest from both radiologists and clinicians.


Assuntos
Extremidades/diagnóstico por imagem , Imagem Radiográfica a Partir de Emissão de Duplo Fóton/métodos , Tomografia Computadorizada por Raios X/métodos , Abdome/diagnóstico por imagem , Humanos
14.
Radiol Med ; 125(1): 7-14, 2020 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-31587181

RESUMO

BACKGROUND: One of the main features of liver fibrosis is the expansion of the interstitial space. All water-soluble CT contrast agents remain confined in the vascular and interstitial space constituting the fractional extracellular space (fECS). Indirect measure of its expansion can be quantified during equilibrium phase with CT. The goal of this prospective study was to assess the feasibility of dual-energy CT (DECT) with iodine quantification at equilibrium phase in the evaluation of significant fibrosis or cirrhosis. METHODS: Thirty-eight cirrhotic patients (according to Child-Pugh and MELD scores), scheduled for liver CT, were enrolled in the study group. Twenty-four patients undergoing CT urography with a 10-min excretory phase were included in the control group. fECS was calculated as the ratio of the iodine concentration of liver parenchyma to that of the aorta, multiplied by 1 minus hematocrit. RESULTS: Final study and control group were, respectively, composed of 22 and 20 patients. Mean hepatic fECS value was statistically greater in study group (P < 0.05). Positive correlation was observed between hepatic fECS value and MELD score (r = 0.64, P < 0.05). Analysis of variance showed statistical differences between control group and the Child-Pugh grades and between Child-Pugh A and B patients and Child-Pugh C patients (P < 0.05). ROC curves analysis yielded an optimum fECS cutoff value of 26.3% for differentiation of control group and cirrhotic patients (AUC 0.88; 86% sensitivity, 85% specificity). CONCLUSIONS: Dual-source DECT is a feasible, noninvasive method for the assessment of significant liver fibrosis or cirrhosis.


Assuntos
Espaço Extracelular/diagnóstico por imagem , Cirrose Hepática/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Idoso , Idoso de 80 Anos ou mais , Estudos de Casos e Controles , Estudos de Viabilidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Curva ROC
15.
Surg Radiol Anat ; 42(4): 449-452, 2020 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-31707433

RESUMO

The biliary tree and the pancreatic ducts originate from different buds of the primitive foregut. A plethora of anatomical variants and congenital anomalies have been described for both the biliary and the pancreatic duct systems, although they are usually asymptomatic. However, in some cases, these abnormalities can lead to serious clinical scenarios, especially when involving the biliopancreatic junction, with consequent mixing and reflux of the two different juices. To the best of our knowledge, we present the first case of pancreas divisum ducts draining into a choledochal cyst, with the lower third of the choledochus configuring a common biliopancreatic duct, in a child suffering from cholelithiasis and acute pancreatitis.


Assuntos
Cisto do Colédoco/diagnóstico por imagem , Colelitíase/diagnóstico por imagem , Pâncreas/anormalidades , Pancreatite/diagnóstico por imagem , Pré-Escolar , Colangiopancreatografia por Ressonância Magnética , Cisto do Colédoco/etiologia , Colelitíase/etiologia , Feminino , Humanos , Pancreatite/etiologia
16.
Rep Pract Oncol Radiother ; 25(3): 299-306, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32194349

RESUMO

Limited liver metastases represent a clinical challenge. Surgical approach is the most frequently reported treatment option, however, some patients are not eligible for surgical interventions. Relatively recent technologic advances have permitted the safe use of ablative techniques employed in the cure of hepatic metastases. Among these, radiofrequency ablation (RFA) and stereotactic body radiotherapy (SBRT) have emerged as valid treatments in a significant proportion of patients with intrahepatic oligometastatic disease. This review offers an up-to-date of current available literature on this issue focusing on the use and outcomes of RFA and SBRT, according to the PICO (Population, Intervention, Comparison and Outcomes) criteria.

17.
Eur Radiol ; 28(4): 1393-1401, 2018 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-29018926

RESUMO

OBJECTIVES: To define optimal window settings for displaying virtual monoenergetic images (VMI) of dual-energy CT pulmonary angiography (DE-CTPA). METHODS: Forty-five patients who underwent clinically-indicated third-generation dual-source DE-CTPA were retrospectively evaluated. Standard linearly-blended (M_0.6), 70-keV traditional VMI (M70), and 40-keV noise-optimised VMI (M40+) reconstructions were analysed. For M70 and M40+ datasets, the subjectively best window setting (width and level, B-W/L) was independently determined by two observers and subsequently related with pulmonary artery attenuation to calculate separate optimised values (O-W/L) using linear regression. Subjective evaluation of image quality (IQ) between W/L settings were assessed by two additional readers. Repeated measures of variance were performed to compare W/L settings and IQ indices between M_0.6, M70, and M40+. RESULTS: B-W/L and O-W/L for M70 were 460/140 and 450/140, and were 1100/380 and 1070/380 for M40+, respectively, differing from standard DE-CTPA W/L settings (450/100). Highest subjective scores were observed for M40+ regarding vascular contrast, embolism demarcation, and overall IQ (all p<0.001). CONCLUSIONS: Application of O-W/L settings is beneficial to optimise subjective IQ of VMI reconstructions of DE-CTPA. A width slightly less than two times the pulmonary trunk attenuation and a level approximately of overall pulmonary vessel attenuation are recommended. KEY POINTS: • Application of standard window settings for VMI results in inferior image perception. • No significant differences between B-W/L and O-W/L for M70/M40+ were observed. • O-W/L for M70 were 450/140 and were 1070/380 for M40+. • Improved subjective IQ characteristics were observed for VMI displayed with O-W/L.


Assuntos
Angiografia por Tomografia Computadorizada/métodos , Processamento de Imagem Assistida por Computador/métodos , Embolia Pulmonar/diagnóstico por imagem , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Artéria Pulmonar/diagnóstico por imagem , Imagem Radiográfica a Partir de Emissão de Duplo Fóton/métodos , Reprodutibilidade dos Testes , Estudos Retrospectivos , Razão Sinal-Ruído
18.
J Cardiovasc Magn Reson ; 19(1): 83, 2017 Nov 06.
Artigo em Inglês | MEDLINE | ID: mdl-29110679

RESUMO

BACKGROUND: Reducing time and contrast agent doses are important goals to provide cost-efficient cardiovascular magnetic resonance (CMR) imaging. Limited information is available regarding the feasibility of evaluating left ventricular (LV) function after gadobutrol injection as well as defining the lowest dose for high quality scar imaging. We sought to evaluate both aspects separately and systematically to provide an optimized protocol for contrast-enhanced CMR (CE-CMR) using gadobutrol. METHODS: This is a prospective, randomized, single-blind cross-over study performed in two different populations. The first population consisted of 30 patients with general indications for a rest CE-CMR who underwent cine-imaging before and immediately after intravenous administration of 0.1 mmol/kg body-weight of gadobutrol. Quantitative assessment of LV volumes and function was performed by the same reader in a randomized and blinded fashion. The second population was composed of 30 patients with indication to late gadolinium enhancement (LGE) imaging, which was performed twice at different gadobutrol doses (0.1 mmol/kg vs. 0.2 mmol/kg) and at different time delays (5 and 10 min vs. 5, 10, 15 and 20 min), within a maximal interval of 21 days. LGE images were analysed qualitatively (contrast-to-noise ratio) and quantitatively (LGE%-of-mass). RESULTS: Excellent correlation between pre- and post-contrast cine-imaging was found, with no difference of LV stroke volume and ejection fraction (p = 0.538 and p = 0.095, respectively). End-diastolic-volume and end-systolic-volume were measured significantly larger after contrast injection (p = 0.008 and p = 0.001, respectively), with a mean difference of 3.7 ml and 2.9 ml, respectively. LGE imaging resulted in optimal contrast-to-noise ratios 10 min post-injection for a gadobutrol dose of 0.1 mmol/kg body-weight and 20 min for a dose of 0.2 mmol/kg body-weight. At these time points LGE quantification did not significantly differ (0.1 mmol/kg: 11% (16.4); 0.2 mmol/kg: 12% (14.5); p = 0.059), showing excellent correlation (ICC = 0.957; p < 0.001). CONCLUSION: A standardized CE-CMR rest protocol giving a dose of 0.1 mmol/kg of gadobutrol before cine-imaging and performing LGE 10 min after injection represents a fast low-dose protocol without significant loss of information in comparison to a longer protocol with cine-imaging before contrast injection and a higher dose of gadobutrol. This approach allows to reduce examination time and costs as well as minimize contrast-agent exposure.


Assuntos
Meios de Contraste/administração & dosagem , Cardiopatias/diagnóstico por imagem , Imagem Cinética por Ressonância Magnética/métodos , Miocárdio/patologia , Compostos Organometálicos/administração & dosagem , Volume Sistólico , Função Ventricular Esquerda , Fluxo de Trabalho , Administração Intravenosa , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Cardiopatias/patologia , Cardiopatias/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Estudos Prospectivos , Reprodutibilidade dos Testes , Método Simples-Cego , Fatores de Tempo , Sobrevivência de Tecidos
19.
Radiol Med ; 121(1): 19-26, 2016 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-26231253

RESUMO

PURPOSE: The aim of this article is to correlate the radiological features of pleuro-pulmonary damage caused by inhalation of pumice (an extrusive volcanic rock classified as a non-fibrous, amorphous, complex silicate) with exposure conditions. MATERIALS AND METHODS: 36 subjects employed in the pumice quarries were evaluated for annual follow-up in a preventive medical surveillance program including spirometry, chest CT lasting from 1999 to 2014. They were only male subjects, mean age 56.92 ± 16.45 years. Subjects had worked in the quarries for an average of 25.03 ± 9.39 years. Domestic or occupational exposure to asbestos or other mineral dusts other than pumice was excluded. Subjects were also classified as smokers, former smokers and nonsmokers. RESULTS: Among the 36 workers examined, we identified four CT patterns which resulted to be dependent on exposure duration and intensity, FVC, FEV1 and FEF25-75, but not on cigarette smoking. The most common symptoms reported by clinical examination were dyspnoea, cough and asthenia. In no case it was proven an evolution of CT findings during follow-up for 10 years. CONCLUSIONS: Liparitosis, caused by pumice inhalation, can be considered a representative example of pneumoconiosis derived by amorphous silica compounds, which are extremely widespread for industrial manufacturing as well as for applicative uses, such as nano-materials. Moreover, being pumice free of quartz contamination, it can represent a disease model for exposure to pure non-fibrous silicates.


Assuntos
Exposição por Inalação/efeitos adversos , Exposição Ocupacional/efeitos adversos , Pneumoconiose/diagnóstico por imagem , Pneumoconiose/etiologia , Silicatos/toxicidade , Tomografia Computadorizada por Raios X/métodos , Adulto , Idoso , Poeira , Humanos , Itália , Masculino , Microscopia Eletrônica de Varredura , Pessoa de Meia-Idade , Pneumoconiose/fisiopatologia , Testes de Função Respiratória
20.
Radiology ; 296(2): E127-E128, 2020 08.
Artigo em Inglês | MEDLINE | ID: mdl-32484417
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa