Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 17 de 17
Filtrar
1.
Catheter Cardiovasc Interv ; 93(3): 559-561, 2019 02 15.
Artigo em Inglês | MEDLINE | ID: mdl-30244527
2.
Catheter Cardiovasc Interv ; 92(2): 390-398, 2018 08 01.
Artigo em Inglês | MEDLINE | ID: mdl-29316204

RESUMO

BACKGROUND: Transfemoral transcatheter aortic valve replacement (TAVR) was superior to surgical aortic valve replacement (SAVR) in the placement of aortic transcatheter valves (PARTNER) 2A trial (P2). The generalizability of the trial results to the broader population of patients with intermediate surgical risk remains unknown. OBJECTIVE: To compare the outcomes of SAVR and TAVR among patients with intermediate surgical risk treated in the VA Healthcare System. METHODS: We retrospectively analyzed the clinical characteristics and outcomes on all SAVR (1987-2014) and TAVR procedures (2015-2017) performed at the Minneapolis VA Healthcare System. Patients were divided into three groups based on their estimated 30-day mortality risk. The primary outcome was a composite of death or stroke at 30-days. RESULTS: A total of 1,049 patients underwent SAVR with (n = 468, 45%) or without CABG (n = 581, 55%) and 110 underwent TAVR during the study period. Intermediate-risk patients represented 29.4% and 40% of patients undergoing SAVR and TAVR, respectively. The predicted 30-day mortality risk of intermediate-risk patients was 5.5% for the SAVR group and 5.2% for the TAVR group (P = 0.54). The observed combined rate of stroke or death at 30-days for intermediate-risk patients treated with SAVR and TAVR was 11% and 2.2%, respectively (P = 0.05). The results for SAVR and TAVR at the VA were comparable to the P2 trial and STS database (all P = NS). The results did not change when the analysis was restricted to a more contemporary (2005-2014) surgical cohort or isolated SAVR. The number needed to treat to prevent one death/stroke with TAVR was 10. CONCLUSIONS: Adoption of TAVR as the preferred treatment modality in intermediate-risk patients may result in significant improvements in morbidity and mortality.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Implante de Prótese de Valva Cardíaca/métodos , Substituição da Valva Aórtica Transcateter/métodos , United States Department of Veterans Affairs , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/mortalidade , Estenose da Valva Aórtica/fisiopatologia , Feminino , Próteses Valvulares Cardíacas , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/instrumentação , Implante de Prótese de Valva Cardíaca/mortalidade , Hemodinâmica , Humanos , Masculino , Pessoa de Meia-Idade , Recuperação de Função Fisiológica , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/mortalidade , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/instrumentação , Substituição da Valva Aórtica Transcateter/mortalidade , Resultado do Tratamento , Estados Unidos
4.
Pacing Clin Electrophysiol ; 34(3): 331-8, 2011 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-21208223

RESUMO

BACKGROUND: Approximately 20,000 permanent pacemakers (PPMs) are implanted annually for bradycardia or atrioventricular (AV) block after cardiac surgery. Little is known about the long-term pacing and mortality outcomes and the temporal trends of these patients. METHODS: We examined 6,268 consecutive patients who underwent cardiac surgery at the Minneapolis Veterans Administration Medical Center between 1987 and 2010. Patients who had a PPM within 30 days of cardiac surgery were identified. Pacemaker interrogation records were retrospectively reviewed and mortality was ascertained. RESULTS: Overall, 141 (2.2%) patients underwent PPM implantation for high-degree AV block (55%) and bradycardia (45%), 9 ± 6 days after surgery. Age, diuretic use, cardiopulmonary bypass time (CPBT), and valve surgery were independent predictors of PPM requirement. After 5.6 ± 4.2 years of follow-up, 40% of the patients were PPM dependent. Longer CPBT (P = 0.03), PR interval >200 ms (P = 0.03), and QRS interval > 120 ms (P = 0.04) on baseline electrocardiogram predicted PPM dependency . In univariable analysis, PPM patients had a higher long-term mortality than those without PPM (45% vs 36%; P = 0.02). However, after adjusting for age, sex, type of surgery, and CPBT, PPM requirement was not associated with long-term mortality (hazard ratio 1.3; 95% confidence interval 0.9-1.9; P = 0.17). Compared to before, incidence of PPM implantation increased after the year 2000 (1.9% vs 2.6%; P = 0.04). CONCLUSION: The majority of patients who require PPM after cardiac surgery are not PPM dependent in the long term. Requiring a PPM after surgery is not associated with long-term mortality after adjustment for patient-related risk factors and cardiac surgical procedure.


Assuntos
Estimulação Cardíaca Artificial/mortalidade , Procedimentos Cirúrgicos Cardiovasculares/mortalidade , Marca-Passo Artificial/estatística & dados numéricos , Implantação de Prótese/mortalidade , Idoso , Terapia Combinada , Segurança de Equipamentos , Feminino , Humanos , Itália/epidemiologia , Estudos Longitudinais , Masculino , Prevalência , Medição de Risco , Fatores de Risco , Análise de Sobrevida , Taxa de Sobrevida , Resultado do Tratamento , Estados Unidos/epidemiologia
5.
Cardiovasc Revasc Med ; 28S: 158-160, 2021 07.
Artigo em Inglês | MEDLINE | ID: mdl-32888838

RESUMO

Stroke remains an important risk during transcatheter aortic valve implantation (TAVI). Though the use of the double-filter Sentinel cerebral protection system (Boston Scientific, Marlborough, MA, USA) may lower the stroke risk, the deployment of this device requires manipulation within the aortic arch and cranial arch vessels potentially causing dislodgment of atherosclerotic debris in the process thereby possibly offsetting its benefit with regards to reducing cerebral embolization. Apart from patient selection, minimizing maneuvering during deployment may improve the safety of device deployment. In this context, we illustrate a case using three-dimensional computed tomography (CT) - overlay to facilitate Sentinel cerebral protection system deployment during TAVI. Emphasis in this case rests on demonstration of how aforementioned periprocedural imaging may facilitate negotiation of anatomical variants and avoid inadvertent cannulation of an anomalous left vertebral artery originating from the aortic arch. Imaging guidance with this concept may minimize device manipulation and reduce the risk of cerebral embolization. Further systematic evaluation is needed to demonstrate whether this approach improves clinical outcomes.


Assuntos
Estenose da Valva Aórtica , Embolia Intracraniana , Substituição da Valva Aórtica Transcateter , Aorta Torácica/diagnóstico por imagem , Aorta Torácica/cirurgia , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Humanos , Embolia Intracraniana/diagnóstico por imagem , Embolia Intracraniana/etiologia , Embolia Intracraniana/prevenção & controle , Imagem Multimodal , Tomografia Computadorizada por Raios X , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento , Artéria Vertebral/diagnóstico por imagem , Artéria Vertebral/cirurgia
6.
Cardiovasc Revasc Med ; 21(11S): 54-59, 2020 11.
Artigo em Inglês | MEDLINE | ID: mdl-32771400

RESUMO

Transcatheter mitral valve-in-ring implantation (TMViR) poses unique challenges when compared to valve-in-valve implantation due to the large variation in the different annuloplasty rings used. Annuloplasty rings are often classified according to whether they are complete or incomplete, rigid, semi-rigid, or flexible, and whether their three-dimensional geometry is saddle-shaped or flat. A limited number of annuloplasty rings are available which are adjustable allowing the surgeon to increase or decrease the size of the ring once it has been sutured in place. To our knowledge there has been no description of TMViR in such adjustable complete rings and recommendations on THV sizing and implantation are not available on the Valve-in-Valve application. Here we report a case of TMViR in an adjustable annuloplasty ring (Attune ring, Abbott, Chicago, IL, USA) and review the literature on TMViR.


Assuntos
Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Anuloplastia da Valva Mitral , Insuficiência da Valva Mitral , Chicago , Humanos , Valva Mitral/cirurgia , Insuficiência da Valva Mitral/cirurgia , Desenho de Prótese
7.
Cardiovasc Diagn Ther ; 10(2): 223-226, 2020 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-32420102

RESUMO

This is a case of an anomalous left circumflex coronary artery (LCX) originating from the right coronary cusp with a retroaortic course in a patient with severe aortic valve stenosis requiring transcatheter aortic valve implantation (TAVI). In the context of TAVI, an anomalous LCX has been described only in a few case reports. In some, the LCX remains unaffected. However, occlusion after TAVI valve deployment has been described. We report pre-procedural imaging and procedural precautions prior to valve deployment in our case in which the LCX remained unaffected by the TAVR valve. More case reports or series are needed to help assess which characteristics are associated with an increased risk of anomalous LCX obstruction.

8.
J Invasive Cardiol ; 31(6): 166-170, 2019 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-30865913

RESUMO

BACKGROUND: The optimal timing of aortic valve replacement (AVR) among patients with asymptomatic severe aortic stenosis (AS) remains uncertain and controversial. METHODS: We conducted a cohort study of consecutive patients with severe AS (mean gradient, 40 mm Hg; aortic valve area <1 cm², or peak velocity ≥4 m/s) who were asymptomatic at the time of echocardiography (2005-2015). Outcomes included mortality, AVR, or AS symptoms. Kaplan-Meier curves and the log-rank test were used to compare the outcomes of patients treated with AVR compared with conservative management. Cox proportional-hazards regression analysis was performed to identify predictors of long-term mortality. RESULTS: Of 1181 echocardiograms and medical records reviewed, a total of 324 patients met inclusion criteria. The mean age of the study cohort was 78 ± 10 years and 97% were male. The median follow-up time was 8 years (interquartile range [IQR], 7-10 years), during which 147 patients (51%) underwent AVR and 94 patients (29%) died. The median survival for patients treated with AVR was 10 years (IQR, 9-10 years) and for patients managed conservatively was 4.8 years (IQR, 3.7-5.7 years; P<.001). A total of 47 patients (14% of the cohort and 48% of deaths) expired before AS symptoms were documented in their medical records. Independent predictors of mortality were age (hazard ratio [HR] per increase in decile, 1.14; 95% CI, 1.05-1.24; P<.01) and performance of AVR during follow-up (HR, 0.15; 95% CI, 0.9-0.28; P<.01). CONCLUSION: A significant proportion of elderly patients with initially asymptomatic severe AS died before symptoms were identified. Our study highlights the difficulty of relying on symptoms alone for timely referral to AVR surgery.


Assuntos
Estenose da Valva Aórtica/diagnóstico , Valva Aórtica/diagnóstico por imagem , Doenças Assintomáticas , Ecocardiografia/métodos , Implante de Prótese de Valva Cardíaca/métodos , Sistema de Registros , Função Ventricular Esquerda/fisiologia , Idoso , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/cirurgia , Feminino , Humanos , Masculino , Prognóstico , Estudos Retrospectivos , Fatores de Risco , Índice de Gravidade de Doença , Veteranos
9.
Sci Rep ; 9(1): 16584, 2019 11 12.
Artigo em Inglês | MEDLINE | ID: mdl-31719596

RESUMO

Amyloid infiltration of the atrium is described in patients with valvular heart disease and is associated with an increased risk for atrial fibrillation(AF) while amyloid deposits in the ventricles is increasingly being diagnosed in patients with HFpEF. The role of amyloid deposits in patients with AF without valvular heart disease, which represents the most common form of AF globally, is undefined. In this study, we sought to assess the prevalence of sub-clinical isolated cardiac amyloidosis (ICA) at autopsy and the odds of AF in these patients. A total of 1083 patients were included in the study and 3.1% of patients were found to have asymptomatic ICA. Patients with ICA were older and had a higher odds of AF independent of age and CHA2DS2VASc score. Amongst patients with AF, those with ICA were more likely to have persistent forms of AF and had a lower sinus rhythm P-wave amplitude. Further studies are required to further define this entity, identify imaging modalities to aid in antemortem diagnosis of ICA and to establish the optimal management strategies in these patients.


Assuntos
Amiloide/química , Amiloidose/epidemiologia , Fibrilação Atrial/fisiopatologia , Cardiopatias/epidemiologia , Idoso , Idoso de 80 Anos ou mais , Amiloidose/diagnóstico , Feminino , Cardiopatias/diagnóstico , Humanos , Masculino , Minnesota/epidemiologia , Prognóstico
10.
Cardiovasc Revasc Med ; 19(5 Pt B): 626-631, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29352699

RESUMO

OBJECTIVES: The lower limit of the membranous septum (MS) is considered an anatomic landmark for the emergence of the Bundle of His into the left ventricle. Computed tomography (CT) assessment of MS anatomy may provide useful information about the risk of conduction abnormalities following transcatheter aortic valve replacement (TAVR). METHODS AND RESULTS: The study included 102 consecutive patients undergoing TAVR with the Edwards Sapien 3 (S3) valve. Using pre-TAVR CT and post-procedure angiography we evaluated for the presence of calcium in the left ventricular outflow tract (LVOT), calcium depth (CD), implantation depth (ID) and MS length. The MS length minus the prosthesis ID was calculated (Delta MSID). Outcomes included new left bundle branch block (LBBB) or permanent pacemaker (PPM) within 30days. Seventeen patients (17%) received a PPM and 28 (27%) developed new LBBB following TAVR. Mean (±SD) MS length and delta MSID were 7.5mm (2) and 0.9mm (4.5), respectively. Twenty-one patients (20%) had calcium in the device landing zone and the mean (SD) CD was 6.8mm (±4). Calcium in the device landing zone (37% versus 16%, p=0.02) and implantation depth (6mm (4-8) versus 4mm (4-5), p=0.02) predicted new conduction abnormalities after TAVR. CONCLUSIONS: The presence of calcium in the device landing zone is associated with increased risk of conduction abnormalities after TAVR with S3. In such cases, a more aortic deployment of the prosthesis may be warranted.


Assuntos
Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Aortografia/métodos , Valvuloplastia com Balão , Angiografia por Tomografia Computadorizada/métodos , Angiografia Coronária/métodos , Septos Cardíacos/diagnóstico por imagem , Próteses Valvulares Cardíacas , Tomografia Computadorizada Multidetectores/métodos , Substituição da Valva Aórtica Transcateter/instrumentação , Idoso , Idoso de 80 Anos ou mais , Pontos de Referência Anatômicos , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/etiologia , Arritmias Cardíacas/terapia , Valvuloplastia com Balão/efeitos adversos , Cálcio/análise , Estimulação Cardíaca Artificial , Tomada de Decisão Clínica , Eletrocardiografia , Feminino , Septos Cardíacos/química , Humanos , Masculino , Marca-Passo Artificial , Valor Preditivo dos Testes , Desenho de Prótese , Fatores de Risco , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
11.
Cardiovasc Revasc Med ; 19(5 Pt B): 621-625, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29276174

RESUMO

BACKGROUND: Subclinical leaflet thrombosis (SCLT) can be seen in up to 12% of patients after transcatheter aortic valve replacement (TAVR). Anticoagulation appears to prevent and reverse SCLT but concerns exist about bleeding risk. METHODS: Our program adopted a strategy of routine anticoagulation after TAVR, starting warfarin on post-procedure day 0 and continuing for 3months in 10/2015. We report the initial safety and efficacy outcomes of this approach. Bleeding events were assessed using Valve Academic Research Consortium (VARC) and Bleeding Academic Research Consortium (BARC) definitions. RESULTS: The median (IQR) age of the population (n=191) was 82years (72-87) and the median (IQR) STS score was 5.6% (3-8). A total of 101 (53%) patients were discharged on anticoagulation (warfarin 97%) while 90 (47%) received antiplatelet therapy alone. The mean duration of anticoagulation therapy was 81±17 days. During follow-up 7 patients (4%) had a stroke or TIA, 3 (3%) in the anticoagulation group and 4 (4%) in the antiplatelet group (p=0.71). A total of 8 patients (4.2%) had BARC bleeding events during follow-up, 3 patients in the anticoagulation group (2.9%) and 5 in the antiplatelet group (5.5%, p=0.48). All bleeding events (VARC and BARC) were numerically lower in the anticoagulation group (8% versus 13%, p=0.20). CONCLUSIONS: A strategy of routine anticoagulation for 3-months after TAVR is well tolerated and associated with similar or lower bleeding risk compared to antiplatelet therapy.


Assuntos
Anticoagulantes/administração & dosagem , Valva Aórtica/cirurgia , Fibrinolíticos/administração & dosagem , Doenças das Valvas Cardíacas/cirurgia , Trombose/prevenção & controle , Substituição da Valva Aórtica Transcateter , Varfarina/administração & dosagem , Idoso , Idoso de 80 Anos ou mais , Anticoagulantes/efeitos adversos , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Esquema de Medicação , Feminino , Fibrinolíticos/efeitos adversos , Doenças das Valvas Cardíacas/diagnóstico por imagem , Doenças das Valvas Cardíacas/fisiopatologia , Próteses Valvulares Cardíacas , Hemorragia/induzido quimicamente , Humanos , Masculino , Minnesota , Inibidores da Agregação Plaquetária/administração & dosagem , Medição de Risco , Fatores de Risco , Trombose/diagnóstico por imagem , Trombose/etiologia , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/instrumentação , Resultado do Tratamento , Varfarina/efeitos adversos
12.
J Invasive Cardiol ; 30(6): 207-211, 2018 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-29799425

RESUMO

BACKGROUND: United States veterans have substantially worse baseline health status than the general population, which may limit the health benefits of transcatheter aortic valve replacement (TAVR). The aim of this study is to quantify the health benefits of TAVR in veterans undergoing the procedure within the United States Department of Veterans Affairs (VA) health-care system. METHODS: We prospectively evaluated heath status in 131 elderly veterans undergoing TAVR in the VA healthcare system between 2015 and 2017. Health status was assessed at baseline and 30 days post procedure using the Kansas City Cardiomyopathy Questionnaire 12 (KCCQ-12). Totals and domain-specific (physical limitation, symptoms, quality of life, and social limitation) health statuses were measured and analyzed with a paired t-test. We also conducted stratified analysis by baseline New York Heart Association functional class and N-terminal pro-b type natriuretic peptide levels. RESULTS: Mean patient age was 77 ± 8 years and average Society of Thoracic Surgeons (STS) score was 4.4 (interquartile range, 3-7). Transfemoral access and balloon-expandable valves were used in 118 cases (92%) and 108 cases (83%), respectively. At baseline, overall health status was poor (overall score, 43 ± 19). After TAVR, significant improvements in overall health status (30 ± 18) and domain-specific health status were seen (improvements in physical limitation, 12 ± 20; symptoms, 23 ± 23; quality of life, 20 ± 17; social limitation, 22 ± 21; all P<.001). The majority of patients (88%) had moderate to large improvements in health status. A favorable outcome (alive with KCCQ-12 overall score >60 at 30 days) was seen in 78% of patients. CONCLUSION: Among elderly veterans with severe aortic stenosis, TAVR is associated with significant improvements in short-term health status.


Assuntos
Estenose da Valva Aórtica/cirurgia , Cateterismo Cardíaco/métodos , Nível de Saúde , Substituição da Valva Aórtica Transcateter/métodos , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/cirurgia , Feminino , Hospitais de Veteranos , Humanos , Masculino , Estudos Prospectivos , Qualidade de Vida , Inquéritos e Questionários , Resultado do Tratamento , Estados Unidos , Veteranos
13.
Cardiovasc Revasc Med ; 19(2): 192-195, 2018 03.
Artigo em Inglês | MEDLINE | ID: mdl-28923694

RESUMO

BACKGROUND: Transcatheter Aortic Valve Replacement (TAVR) is increasingly performed using a minimalist approach under monitored anesthesia care (MAC). The safety of this approach remains controversial and adoption has been low in the US. METHODS: The study cohort was comprised of 130 patients (98% male) who underwent TAVR between 4/2015 and 4/2017 at the Minneapolis VA. We compared the outcomes of 81 patients who underwent TAVR using a standard approach (standard TAVR) and 49 who underwent TAVR using a minimalist approach (minimalist TAVR). Outcome measures included device and procedural success, procedural efficiency, length of intensive care unit (ICU) and hospital stay, procedural complications and hospital readmissions. RESULTS: Mean age was 80 (±9) years and median (IQR) STS score was 5 (4-6). Access included transfemoral (n = 111, 85%) and alternative (n = 19, 15%). Minimalist TAVR was associated with reduced procedural time: median 101 min (IQR: 78-135) versus 127 min (IQR: 97-182, p = 0.03), fluoroscopy time: median 18 min (IQR: 12-26) versus 24 min (IQR: 16-38), p = 0.001), contrast volume 90 ml (IQR: 70-120 ml) versus 140 ml (IQR: 86-213 ml, p < 0.001). CONCLUSIONS: A minimalistic approach to TAVR is associated with improved procedural efficiency and reduced length of stay without compromising procedural success or clinical outcomes.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Substituição da Valva Aórtica Transcateter/métodos , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/mortalidade , Estenose da Valva Aórtica/fisiopatologia , Feminino , Mortalidade Hospitalar , Hospitais de Veteranos , Humanos , Tempo de Internação , Masculino , Equipe de Assistência ao Paciente , Readmissão do Paciente , Complicações Pós-Operatórias/mortalidade , Complicações Pós-Operatórias/terapia , Desenvolvimento de Programas , Recuperação de Função Fisiológica , Fatores de Risco , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/instrumentação , Substituição da Valva Aórtica Transcateter/mortalidade , Resultado do Tratamento , Estados Unidos , Fluxo de Trabalho
14.
JACC Clin Electrophysiol ; 3(9): 1037-1045, 2017 09.
Artigo em Inglês | MEDLINE | ID: mdl-29759708

RESUMO

OBJECTIVES: The study examined the frequency in which a right coronary artery (RCA) anomaly resulting in intra-atrialization of the vessel might increase risk of RCA damage during routine radiofrequency ablation in the right atrium even with low power or temperature. BACKGROUND: Right coronary artery (RCA) injury with endocardial RF ablation of the right atrium is a rare complication. METHODS: This prospective observational study comprised an analysis of coronary artery anatomies in 331 patients who underwent autopsies at our institution from 2005 to 2014. The presence of intra-atrial RCA including the number and length of intra-atrial RCA segments with accompanying atherosclerosis and coronary anomalies were evaluated. RESULTS: The authors report a case series of 6 of 331 (1.8%) patients in whom autopsies showed evidence of an intra-atrial RCA. The patients were all men (average 69 ± 12 years of age). They observed 3 variations of the intra-atrial RCA course. In 2 similar variations, the RCA entered the anterolateral aspect of the right atrium, returning to its normal distribution to supply the distal RCA (case 4 of 6) and the atrioventricular nodal artery (case 1 of 6). In the sixth case, the atrialized artery was an anterior branch of the RCA, in which the artery similarly coursed across the pectinate muscles, extending to the region of the anterior crista terminalis, before diving into the muscle. CONCLUSIONS: The prevalence and variants of the intra-atrial RCA have not been reported before. In the presence of an intra-atrial artery, RCA damage may occur due to direct injury rather than collateral injury due to transmural extension of an ablation lesion.


Assuntos
Ablação por Cateter/métodos , Doença da Artéria Coronariana/cirurgia , Átrios do Coração/patologia , Idoso , Idoso de 80 Anos ou mais , Autopsia , Doença da Artéria Coronariana/patologia , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa