Resultados 1 - 20 de 35
Filtrar
1.
J Ultrasound Med ; 40(3): 569-581, 2021 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-33410183

RESUMO

OBJECTIVES: To quantify the bias of shear wave speed (SWS) measurements between different commercial ultrasonic shear elasticity systems and a magnetic resonance elastography (MRE) system in elastic and viscoelastic phantoms. METHODS: Two elastic phantoms, representing healthy through fibrotic liver, were measured with 5 different ultrasound platforms, and 3 viscoelastic phantoms, representing healthy through fibrotic liver tissue, were measured with 12 different ultrasound platforms. Measurements were performed with different systems at different sites, at 3 focal depths, and with different appraisers. The SWS bias across the systems was quantified as a function of the system, site, focal depth, and appraiser. A single MRE research system was also used to characterize these phantoms using discrete frequencies from 60 to 500 Hz. RESULTS: The SWS from different systems had mean difference 95% confidence intervals of ±0.145 m/s (±9.6%) across both elastic phantoms and ± 0.340 m/s (±15.3%) across the viscoelastic phantoms. The focal depth and appraiser were less significant sources of SWS variability than the system and site. Magnetic resonance elastography best matched the ultrasonic SWS in the viscoelastic phantoms using a 140 Hz source but had a - 0.27 ± 0.027-m/s (-12.2% ± 1.2%) bias when using the clinically implemented 60-Hz vibration source. CONCLUSIONS: Shear wave speed reconstruction across different manufacturer systems is more consistent in elastic than viscoelastic phantoms, with a mean difference bias of < ±10% in all cases. Magnetic resonance elastographic measurements in the elastic and viscoelastic phantoms best match the ultrasound systems with a 140-Hz excitation but have a significant negative bias operating at 60 Hz. This study establishes a foundation for meaningful comparison of SWS measurements made with different platforms.


Assuntos
Técnicas de Imagem por Elasticidade , Biomarcadores , Elasticidade , Humanos , América do Norte , Imagens de Fantasmas
2.
World J Urol ; 38(7): 1643, 2020 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-31960107

RESUMO

The Eqs. 1, 2 and 3 come under the section "Kidney cortex testing" as per the original manuscript, but they have been incorrectly moved and separated into different sections in the original publication of the article.

3.
World J Urol ; 38(7): 1631-1641, 2020 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-31679063

RESUMO

INTRODUCTION AND OBJECTIVES: There is a scarcity of high-fidelity, life-like, standardized and anatomically correct polymer-based kidney models for robot-assisted partial nephrectomy (RAPN) simulation training. The purpose of this technical report is to present mechanical and functional testing data as evidence for utilizing a perfused hydrogel kidney model created utilizing 3D printed injection casts for RAPN simulation and training. METHODS: Anatomically correct, tumor-laden kidney models were created from 3D-printed casts designed from a patient's CT scan and injected with poly-vinyl alcohol (PVA). A variety of testing methods quantified Young's modulus in addition to comparing the functional effects of bleeding and suturing among fresh porcine kidneys and various formulations of PVA kidneys. RESULTS: 7% PVA at three freeze-thaw cycles (7%-3FT) was found to be the formula that best replicates the mechanical properties of fresh porcine kidney tissue, where mean(± SD) values of Young's modulus of porcine tissue vs 7%-3FT samples were calculated to be 85.97(± 35) kPa vs 80.97(± 9.05) kPa, 15.7(± 1.6) kPa vs 74.56(± 10) kPa and 87.46(± 2.97) kPa vs 83.4(± 0.7) kPa for unconfined compression, indentation and elastography testing, respectively. No significant difference was seen in mean suture tension during renorrhaphy necessary to achieve observable hemostasis and capsular violation during a simulated perfusion at 120 mmHg. CONCLUSIONS: This is the first study to utilize extensive material testing analyses to determine the mechanical and functional properties of a perfused, inanimate simulation platform for RAPN, fabricated using a combination of image segmentation, 3D printing and PVA casting.


Assuntos
Hidrogéis , Rim , Modelos Anatômicos , Nefrectomia/métodos , Impressão Tridimensional , Procedimentos Cirúrgicos Robóticos , Animais , Hidrogéis/administração & dosagem , Perfusão , Suínos
4.
Ultrason Imaging ; 41(5): 251-270, 2019 09.
Artigo em Inglês | MEDLINE | ID: mdl-31271117

RESUMO

Measurement of corneal biomechanical properties can aid in predicting corneal responses to diseases and surgeries. For delineation of spatially resolved distribution of corneal elasticity, high-resolution elastography system is required. In this study, we demonstrate a high-resolution elastography system using high-frequency ultrasound for ex-vivo measurement of intraocular pressure (IOP)-dependent corneal wave speed. Tone bursts of 500 Hz vibrations were generated on the corneal surface using an electromagnetic shaker. A 35-MHz single-element transducer was used to track the resulting anti-symmetrical Lamb wave in the cornea. We acquired spatially resolved wave speed images of the cornea at IOPs of 7, 11, 15, 18, 22, and 29 mmHg. The IOP dependence of corneal wave speed is apparent from these images. Statistical analysis of measured wave speed as a function of IOP revealed a linear relation between wave speed and IOP cs = 0.37 + 0.22 × IOP, with the coefficient of determination R2 = 0.86. We also observed depth-dependent variations of wave speed in the cornea, decreasing from anterior toward posterior. This depth dependence is more pronounced at higher IOP values. This study demonstrates the potential of high-frequency ultrasound elastography in the characterization of spatially resolved corneal biomechanical properties.


Assuntos
Córnea/fisiologia , Técnicas de Imagem por Elasticidade/métodos , Pressão Intraocular/fisiologia , Animais , Córnea/diagnóstico por imagem , Modelos Animais , Suínos
5.
J Acoust Soc Am ; 138(2): EL138-44, 2015 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-26328739

RESUMO

The physical environment of engineered tissues can influence cellular functions that are important for tissue regeneration. Thus, there is a critical need for noninvasive technologies capable of monitoring mechanical properties of engineered tissues during fabrication and development. This work investigates the feasibility of using single tracking location shear wave elasticity imaging (STL-SWEI) for quantifying the shear moduli of tissue-mimicking phantoms and engineered tissues in tissue engineering environments. Scholte surface waves were observed when STL-SWEI was performed through a fluid standoff, and confounded shear moduli estimates leading to an underestimation of moduli in regions near the fluid-tissue interface.


Assuntos
Técnicas de Imagem por Elasticidade/métodos , Engenharia Tecidual , Ultrassom , Animais , Células Cultivadas , Colágeno Tipo I , Módulo de Elasticidade , Estudos de Viabilidade , Fibroblastos/citologia , Gelatina , Hidrogéis , Camundongos , Oscilometria , Imagens de Fantasmas , Resistência ao Cisalhamento , Amido , Transdutores de Pressão , Água
6.
J Acoust Soc Am ; 135(5): 2836-46, 2014 May.
Artigo em Inglês | MEDLINE | ID: mdl-24815265

RESUMO

Shear wave induced phase encoding (SWIPE) imaging generates ultrasound backscatter images of tissue-like elastic materials by using traveling shear waves to encode the lateral position of the scatters in the phase of the received echo. In contrast to conventional ultrasound B-scan imaging, SWIPE offers the potential advantages of image formation without beam focusing or steering from a single transducer element, lateral resolution independent of aperture size, and the potential to achieve relatively high lateral resolution with low frequency ultrasound. Here a Fourier series description of the phase modulated echo signal is developed, demonstrating that echo harmonics at multiples of the shear wave frequency reveal target k-space data at identical multiples of the shear wavenumber. Modulation transfer functions of SWIPE imaging systems are calculated for maximum shear wave acceleration and maximum shear constraints, and compared with a conventionally focused aperture. The relative signal-to-noise ratio of the SWIPE method versus a conventionally focused aperture is found through these calculations. Reconstructions of wire targets in a gelatin phantom using 1 and 3.5 MHz ultrasound and a cylindrical shear wave source are presented, generated from the fundamental and second harmonic of the shear wave modulation frequency, demonstrating weak dependence of lateral resolution with ultrasound frequency.


Assuntos
Acústica , Diagnóstico por Imagem/métodos , Técnicas de Imagem por Elasticidade , Som , Ultrassom/métodos , Aceleração , Algoritmos , Desenho de Equipamento , Análise de Fourier , Gelatina , Periodicidade , Imagens de Fantasmas , Razão Sinal-Ruído
7.
IEEE Trans Biomed Eng ; 71(3): 916-928, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37801375

RESUMO

OBJECTIVE: Viscoelasticity is mapped by dispersion in shearwave elastography. Incomplete spectral information of shearwaves is therefore used to estimate mechanical stiffness. We propose capturing the "full-waveform-information" of the shear wave spectra to better resolve complex shear modulus µ* (ω). Approach is validated on phantom models, animal tissues, and feasibility demonstrated on human post-delivery placenta. METHODS: We captured robust estimates of µ* in ex-vivo livers subjected to water bath ablation, glutaraldehyde exposure and in the placenta. RESULTS: Complex modulus at 200 Hz is more reflective of tissue stiffness than cross-correlation estimate. Bias increased in phantoms with higher gelatin (G) (0.65: 6% G) and oil (O) (0.58: 6% G and 40% O) concentration, compared to elastic phantoms with low stiffness (0.33: 3% G). Actual tissues also reported higher bias in cross-correlation estimate (rabbit liver: 0.61, porcine liver: 2.20, and human placenta: 0.63). Stiffness is sensitive to ablation temperature, where the overall modulus changed from 3.02 KPa at 16 °C to 2.75 KPa at 56 °C in water bath. With exposure to Glutaraldehyde, the overall modulus increased from 2.37 to 9.03 KPa. Reconstruction errors in the loss modulus decreased by 68% with the power law compared to a Maxwell model in porcine livers with Cole-Cole inverse fitting. CONCLUSION: Omitting Shear wave attenuation leads to bias. Reconstruction of rheological response with a model is sensitive to its architecture and also the framework. SIGNIFICANCE: We use "full spectral information" in ultrasound shear wave elastography to better map µ*(ω) changes in viscoelastic tissues.


Assuntos
Técnicas de Imagem por Elasticidade , Humanos , Animais , Suínos , Coelhos , Glutaral , Ultrassonografia , Técnicas de Imagem por Elasticidade/métodos , Viscosidade , Imagens de Fantasmas , Análise Espectral , Água
8.
Appl Opt ; 52(17): 4024-34, 2013 Jun 10.
Artigo em Inglês | MEDLINE | ID: mdl-23759852

RESUMO

Stereotactically placed guidewires are used for indicating the location of a nonpalpable carcinoma in breast-conserving surgery. Pathologists use the end of the embedded guidewire to guide sectioning during intraoperative margin assessment, but they do not currently have a tool to indicate the location of the guidewire end for informed sectioning. We present analysis and experimental testing of two optical methods for localizing the end of an embedded fiber-optic guidewire: the first uses irradiance emitted from the fiber to indicate the location of the guidewire end, while the second system uses the fiber optic to create a photoacoustic pulse for localization. Both systems locate the end of the guidewire within ±5 mm, which ensures that the lesion of interest is bisected during sectioning. The accuracy of the irradiance-based beacon is influenced by standard margin paints, so the photoacoustic beacon proved more useful under current tissue-handling protocols.


Assuntos
Tecnologia de Fibra Óptica/instrumentação , Marcadores Fiduciais , Lasers , Iluminação/instrumentação , Mastectomia Segmentar/instrumentação , Fotometria/instrumentação , Técnicas Estereotáxicas/instrumentação , Cirurgia Assistida por Computador/métodos , Animais , Desenho de Equipamento , Análise de Falha de Equipamento , Suínos
9.
Artigo em Inglês | MEDLINE | ID: mdl-34986096

RESUMO

Imaging tissue mechanical properties has shown promise in noninvasive assessment of numerous pathologies. Researchers have successfully measured many linear tissue mechanical properties in laboratory and clinical settings. Currently, multiple complex mechanical effects such as frequency-dependence, anisotropy, and nonlinearity are being investigated separately. However, a concurrent assessment of these complex effects may enable more complete characterization of tissue biomechanics and offer improved diagnostic sensitivity. In this work, we report for the first time a method to map the frequency-dependent nonlinear parameters of soft tissues on a local scale. We recently developed a nonlinear elastography model that combines strain measurements from arbitrary tissue compression with radiation-force-based broadband shear wave speed (WS) measurements. Here, we extended this model to incorporate local measurements of frequency-dependent shear modulus. This combined approach provides a local frequency-dependent nonlinear parameter that can be obtained with arbitrary, clinically realizable tissue compression. Initial assessments using simulations and phantoms validate the accuracy of this approach. We also observed improved contrast in nonlinearity parameter at higher frequencies. Results from ex-vivo liver experiments show 32, 25, 34, and 38 dB higher contrast in elastograms than traditional linear elasticity, elastic nonlinearity, viscosity, and strain imaging methods, respectively. A lesion, artificially created by injection of glutaraldehyde into a liver specimen, showed a 59% increase in the frequency-dependent nonlinear parameter and a 17% increase in contrast ratio.


Assuntos
Técnicas de Imagem por Elasticidade , Anisotropia , Elasticidade , Técnicas de Imagem por Elasticidade/métodos , Imagens de Fantasmas , Viscosidade
10.
Artigo em Inglês | MEDLINE | ID: mdl-34236961

RESUMO

The acoustic radiation force impulse (ARFI) has been widely used in transient shear wave elasticity imaging (SWEI). For SWEI based on focused ARFI, the highest image quality exists inside the focal zone due to the limitation of the depth of focus and diffraction. Consequently, the areas outside the focal zone and in the near field present poor image quality. To address the limitations of the focused beam, we introduce Bessel apodized ARFI that enhances image quality and improves the depth of focus. The objective of this study is to evaluate the feasibility of SWEI based on Bessel ARF in simulation and experiment. We report measurements of elastogram image quality and depth of field in tissue-mimicking phantoms and ex vivo liver tissue. Our results demonstrate improved depth of field, image quality, and shear wave speed (SWS) estimation accuracy using Bessel push beams. As a result, Bessel ARF enlarges the field of view of elastograms. The signal-to-noise ratio (SNR) of Bessel SWEI is improved 26% compared with focused SWEI in homogeneous phantom. The estimated SWS by Bessel SWEI is closer to the measured SWS from a clinical scanner with an error of 0.3% compared to 2.4% with a focused beam. In heterogeneous phantoms, the contrast-to-noise ratios (CNRs) of shallow and deep inclusions are improved by 8.79 and 3.33 dB, respectively, under Bessel ARF. We also compare the results between Bessel SWEI and supersonic shear imaging (SSI), and the SNR of Bessel SWEI is improved by 8.1%. Compared with SSI, Bessel SWEI shows more accurate SWS estimates in high stiffness inclusions. Finally, Bessel SWEI can generate higher quality elastograms with less energy than conventional SSI.


Assuntos
Técnicas de Imagem por Elasticidade , Acústica , Elasticidade , Imagens de Fantasmas , Razão Sinal-Ruído
11.
Phys Med Biol ; 66(22)2021 11 18.
Artigo em Inglês | MEDLINE | ID: mdl-34715685

RESUMO

Compressional or quasi-static elastography has demonstrated the capability to detect occult cancers in a variety of tissue types, however it has a serious limitation in that the resulting elastograms are generally qualitative whereas other forms of elastography, such as shear-wave, can produce absolute measures of elasticity for histopathological classification. We address this limitation by introducing a stochastic method using an extended Kalman filter and robot-assistance to obtain quantitative elastograms which are resilient to measurement noise and system uncertainty. In this paper, the probabilistic framework is described, which utilizes many ultrasound acquisitions obtained from multiple palpations, to fuse data and uncertainty from a robotic manipulator's joint encoders and force/torque sensor directly into the inverse reconstruction of the elastogram. Quantitative results are demonstrated over homogeneous and inclusion gelatin phantoms using a seven degree of freedom manipulator for a range of initial elasticity assumptions. Results imply resilience to poorly assumed initial conditions as all trials were within 5 kPa of the elasticity measured by a mechanical testing system. Moreover, the presence or absence of an inclusion is clear in all reconstructed elastograms even when artifacts are present in displacement fields, indicating further robustness to measurement noise. The proposed stochastic method allows fusion of data from a robot's sensors directly into compressional elastography image reconstruction which may stabilize optimization and improve accuracy. This approach provides a mathematical framework to readily incorporate measurements from additional sensors in future applications which may extend the capabilities of compressional elastography beyond that of producing quantitative elasticity measurements.


Assuntos
Técnicas de Imagem por Elasticidade , Robótica , Elasticidade , Técnicas de Imagem por Elasticidade/métodos , Imagens de Fantasmas , Ultrassonografia
12.
IEEE Trans Med Imaging ; 39(11): 3559-3570, 2020 11.
Artigo em Inglês | MEDLINE | ID: mdl-32746104

RESUMO

The goal of non-linear ultrasound elastography is to characterize tissue mechanical properties under finite deformations. Existing methods produce high contrast non-linear elastograms under conditions of pure uni-axial compression, but exhibit bias errors of 10-50% when the applied deformation deviates from the uni-axial condition. Since freehand transducer motion generally does not produce pure uniaxial compression, a motion-agnostic non-linearity estimator is desirable for clinical translation. Here we derive an expression for measurement of the Non-Linear Shear Modulus (NLSM) of tissue subject to combined shear and axial deformations. This method gives consistent nonlinear elasticity estimates irrespective of the type of applied deformation, with a reduced bias in NLSM values to 6-13%. The method combines quasi-static strain imaging with Single-Track Location-Shear Wave Elastography (STL-SWEI) to generate local estimates of axial strain, shear strain, and Shear Wave Speed (SWS). These local values were registered and non-linear elastograms reconstructed with a novel nonlinear shear modulus estimation scheme for general deformations. Results on tissue mimicking phantoms were validated with mechanical measurements and multiphysics simulations for all deformation types with an error in NLSM of 6-13%. Quantitative performance metrics with the new compound-motion tracking strategy reveal a 10-15 dB improvement in Signal-to-Noise Ratio (SNR) for simple shear versus pure compressive deformation for NLSM elastograms of homogeneous phantoms. Similarly, the Contrast-to-Noise Ratio (CNR) of NLSM elastograms of inclusion phantoms improved by 25-30% for simple shear over pure uni-axial compression. Our results show that high fidelity NLSM estimates may be obtained at ~30% lower strain under conditions of shear deformation as opposed axial compression. The reduction in strain required could reduce sonographer effort and improve scan safety.


Assuntos
Técnicas de Imagem por Elasticidade , Elasticidade , Movimento (Física) , Imagens de Fantasmas , Razão Sinal-Ruído
13.
Artigo em Inglês | MEDLINE | ID: mdl-31150340

RESUMO

Nonlinear elasticity imaging provides additional information about tissue behavior that is potentially diagnostic and avoids errors inherent in applying a linear elastic model to tissue under large strains. Nonlinear elasticity imaging is challenging to perform due to the large deformations required to obtain sufficient tissue strain to elicit nonlinear behavior. This work uses a method of axial and lateral displacement tracking to estimate local axial strain with simultaneous measurement of shear modulus at multiple compression levels. By following the change in apparent shear modulus and the stress deduced from the strain maps, we are able to accurately quantify nonlinear shear modulus (NLSM). We have validated our technique with a mechanical NLSM measurement system. Our results demonstrate that 2-D tracking provides more consistent NLSM estimates than those obtained by 1-D (axial) tracking alone, especially where lateral motion is significant. The elastographic contrast-to-noise ratio in heterogeneous phantoms was 12.5%-60% higher using our method than that of 1-D tracking. Our method is less susceptible to mechanical variations, with deviations in mean elastic values of 2%-4% versus 5%-37% for 1-D tracking.


Assuntos
Técnicas de Imagem por Elasticidade/métodos , Algoritmos , Módulo de Elasticidade , Processamento de Imagem Assistida por Computador , Movimento (Física) , Imagens de Fantasmas , Processamento de Sinais Assistido por Computador , Razão Sinal-Ruído
14.
Autism ; 23(2): 359-370, 2019 02.
Artigo em Inglês | MEDLINE | ID: mdl-29212345

RESUMO

We developed an iOS-based app with a transmitter/disposable sensor and corresponding manualized intervention for children with autism spectrum disorder. The app signaled the onset of urination, time-stamped accidents for analysis, reminded parents to reinforce intervals of continence, provided a visual outlet for parents to communicate reinforcement, and afforded opportunity for timely feedback from clinicians. We compared this intervention with an intervention that uses standard behavioral treatment in a pilot randomized controlled trial of 33 children with autism spectrum disorder aged 3-6 years with urinary incontinence. Parents in both groups received initial training and four booster consultations over 3 months. Results support the feasibility of parent-mediated toilet training studies (e.g., 84% retention rate, 92% fidelity of parent-implemented intervention). Parents used the app and related technology with few difficulties or malfunctions. There were no statistically significant group differences for rate of urine accidents, toilet usage, or satisfaction at close of intervention or 3-month follow-up; however, the alarm group trended toward greater rate of skill acquisition with significantly less day-to-day intervention. Further development of alarm and related technology and future comparative studies with a greater number of participants are warranted.


Assuntos
Transtorno do Espectro Autista/reabilitação , Enurese/reabilitação , Aplicativos Móveis , Pais , Treinamento no Uso de Banheiro , Criança , Pré-Escolar , Estudos de Viabilidade , Feminino , Humanos , Masculino , Projetos Piloto , Reforço Psicológico , Tecnologia sem Fio
15.
Artigo em Inglês | MEDLINE | ID: mdl-29993543

RESUMO

Single-track location shear wave elasticity imaging (STL-SWEI) is immune to speckle bias, but the quality of the images is depth dependent. We hypothesize that plane-wave imaging can reduce the depth dependence of STL-SWEI. To test this hypothesis, we developed a novel technique known as plane-wave STL-SWEI (pSTL-SWEI). To evaluate the pSTL-SWEI's potential, we performed studies on phantoms and excised murine pancreatic tumors. The mean shear wave speeds measured with STL-SWEI and pSTL-SWEI were similar. However, the elastographic signal-to-noise ratio (SNRe) of pSTL-SWEI elastograms was noticeably higher than that produced with STL-SWEI. Specifically, we observed an improvement in SNRe ranging from 39.9%-55.1%, depending on tissue stiffness. The spatial resolution of pSTL-SWEI elastograms was 2.7%-12.1% lower than that produced with STL-SWEI. pSTL-SWEI elastograms displayed higher contrast-to-noise ratio (CNRe) than those produced with STL-SWEI, especially when imaging was performed with low push pulse intensities and low pulse durations.


Assuntos
Técnicas de Imagem por Elasticidade/métodos , Processamento de Imagem Assistida por Computador/métodos , Animais , Camundongos , Neoplasias Pancreáticas/diagnóstico por imagem , Imagens de Fantasmas , Processamento de Sinais Assistido por Computador , Razão Sinal-Ruído
16.
Ultrasound Med Biol ; 43(11): 2629-2639, 2017 11.
Artigo em Inglês | MEDLINE | ID: mdl-28830643

RESUMO

The clinical use of elastography for monitoring fibrosis progression is challenged by the subtle changes in liver stiffness associated with early-stage fibrosis and the comparatively large variance in stiffness estimates provided by elastography. Single-tracking-location (STL) shear wave elasticity imaging (SWEI) is an ultrasound elastography technique previously found to provide improved estimate precision compared with multiple-tracking-location (MTL) SWEI. Because of the improved precision, it is reasonable to expect that STL-SWEI would provide improved ability to differentiate liver fibrosis stage compared with MTL-SWEI. However, this expectation has not been previously challenged rigorously. In this work, the performance of STL- and MTL-SWEI in the setting of a rat model of liver fibrosis is characterized, and the advantages of STL-SWEI in staging fibrosis are explored. The purpose of this study was to determine what advantages, if any, arise from using STL-SWEI instead of MTL-SWEI in the characterization of fibrotic liver. Thus, the ability of STL-SWEI to differentiate livers at various METAVIR fibrosis scores, for ex vivo postmortem measurements, is explored. In addition, we examined the effect of the common confounding factor of fluid versus solid boundary conditions in SWEI experiments. Sprague-Dawley rats were treated with carbon tetrachloride over several weeks to produce liver disease of varying severity. STL and MTL stiffness measurements were performed ex vivo and compared with the METAVIR scores from histological analysis and the duration of treatment. A strong association was observed between liver stiffness and weeks of treatment with the liver toxin carbon tetrachloride. Direct comparison of STL- and MTL-SWEI measurements revealed no significant difference in ability to differentiate fibrosis stages based on SWEI mean values. However, image interquartile range was greatly improved in the case of STL-SWEI, compared with MTL-SWEI, at small beam spacing.


Assuntos
Técnicas de Imagem por Elasticidade/métodos , Hepatopatias/diagnóstico por imagem , Hepatopatias/patologia , Fígado/patologia , Animais , Modelos Animais de Doenças , Masculino , Ratos , Ratos Sprague-Dawley
17.
Artigo em Inglês | MEDLINE | ID: mdl-16889337

RESUMO

The use of ultrasonic methods to track the tissue deformation generated by acoustic radiation force is subject to jitter and displacement underestimation errors, with displacement underestimation being primarily caused by lateral and elevation shearing within the point spread function (PSF) of the ultrasonic beam. Models have been developed using finite element methods and Field II, a linear acoustic field simulation package, to study the impact of focal configuration, tracking frequency, and material properties on the accuracy of ultrasonically tracking the tissue deformation generated by acoustic radiation force excitations. These models demonstrate that lateral and elevation shearing underneath the PSF of the tracking beam leads to displacement underestimation in the focal zone. Displacement underestimation can be reduced by using tracking beams that are narrower than the spatial extent of the displacement fields. Displacement underestimation and jitter decrease with time after excitation as shear wave propagation away from the region of excitation reduces shearing in the lateral and elevation dimensions. The use of higher tracking frequencies in broadband transducers, along with 2D focusing in the elevation dimension, will reduce jitter and improve displacement tracking accuracy. Relative displacement underestimation remains constant as a function of applied force, whereas jitter increases with applied force. Underdeveloped speckle (SNR < 1.91) leads to greater levels of jitter and peak displacement underestimation. Axial shearing is minimal over the tracking kernel lengths used in acoustic radiation force impulse imaging and thus does not impact displacement tracking.


Assuntos
Acústica , Algoritmos , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Modelos Biológicos , Movimento , Estimulação Física/métodos , Animais , Simulação por Computador , Humanos , Imageamento Tridimensional/métodos , Armazenamento e Recuperação da Informação/métodos , Movimento (Física) , Doses de Radiação , Radiometria/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
18.
Artigo em Inglês | MEDLINE | ID: mdl-17091842

RESUMO

Acoustic radiation force impulse imaging has been used clinically to study the dynamic response of lesions relative to their background material to focused, impulsive acoustic radiation force excitations through the generation of dynamic displacement field images. Dynamic displacement data are typically displayed as a set of parametric images, including displacement immediately after excitation, maximum displacement, time to peak displacement, and recovery time from peak displacement. To date, however, no definitive trends have been established between these parametric images and the tissues' mechanical properties. This work demonstrates that displacement magnitude, time to peak displacement, and recovery time are all inversely related to the Young's modulus in homogeneous elastic media. Experimentally, pulse repetition frequency during displacement tracking limits stiffness resolution using the time to peak displacement parameter. The excitation pulse duration also impacts the time to peak parameter, with longer pulses reducing the inertial effects present during impulsive excitations. Material density affects tissue dynamics, but is not expected to play a significant role in biological tissues. The presence of an elastic spherical inclusion in the imaged medium significantly alters the tissue dynamics in response to impulsive, focused acoustic radiation force excitations. Times to peak displacement for excitations within and outside an elastic inclusion are still indicative of local material stiffness; however, recovery times are altered due to the reflection and transmission of shear waves at the inclusion boundaries. These shear wave interactions cause stiffer inclusions to appear to be displaced longer than the more compliant background material. The magnitude of shear waves reflected at elastic lesion boundaries is dependent on the stiffness contrast between the inclusion and the background material, and the stiffness and size of the inclusion dictate when shear wave reflections within the lesion will interfere with one another. Jitter and bias associated with the ultrasonic displacement tracking also impact the estimation of a tissue's dynamic response to acoustic radiation force excitation.


Assuntos
Acústica , Tecido Conjuntivo/diagnóstico por imagem , Tecido Conjuntivo/fisiologia , Interpretação de Imagem Assistida por Computador/métodos , Microscopia Acústica/métodos , Modelos Biológicos , Fenômenos Biomecânicos/métodos , Simulação por Computador , Elasticidade , Humanos , Estimulação Física/métodos , Estresse Mecânico
19.
Artigo em Inglês | MEDLINE | ID: mdl-17036791

RESUMO

Constructing an ultrasonic imaging system capable of compensating for phase errors in real-time is a significant challenge in adaptive imaging. We present a versatile adaptive imaging system capable of updating arrival time profiles at frame rates of approximately 2 frames per second (fps) with 1-D arrays and up to 0.81 fps for 1.75-D arrays, depending on the desired near-field phase correction algorithm. A novel feature included in this system is the ability to update the aberration profile at multiple beam locations for 1-D arrays. The features of this real-time adaptive imaging system are illustrated in tissue-mimicking phantoms with physical near-field phase screens and evaluated in clinical breast tissue with a 1.75-D array. The contrast-to-noise ratio (CNR) of anechoic cysts was shown to improve dramatically in the tissue-mimicking phantoms. In breast tissue, the width of point-like targets showed significant improvement: a reduction of 26.2% on average. Brightness of these targets, however, marginally decreased by 3.9%. For larger structures such as cysts, little improvement in features and CNR were observed, which is likely a result of the system assuming an infinite isoplanatic patch size for the 1.75-D arrays. The necessary requirements for constructing a real-time adaptive imaging system are also discussed.


Assuntos
Aumento da Imagem/instrumentação , Interpretação de Imagem Assistida por Computador/instrumentação , Ultrassonografia/instrumentação , Gravação em Vídeo/instrumentação , Sistemas Computacionais , Desenho de Equipamento , Análise de Falha de Equipamento , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Ultrassonografia/métodos , Gravação em Vídeo/métodos
20.
Artigo em Inglês | MEDLINE | ID: mdl-27295662

RESUMO

Elastography provides tissue stiffness information that attempts to characterize the elastic properties of tissue. However, there is still limited literature comparing elastographic modalities for tissue characterization. This study focuses on two quantitative techniques using different vibration sources that have not been compared to date: crawling wave sonoelastography (CWS) and single tracking location shear wave elasticity imaging (STL-SWEI). To understand each technique's performance, shear wave speed (SWS) was measured in homogeneous phantoms and ex vivo beef liver tissue. Then, the contrast, contrast-to-noise ratio (CNR), and lateral resolution were measured in an inclusion and two-layer phantoms. The SWS values obtained with both modalities were validated with mechanical measurements (MM) which serve as ground truth. The SWS results for the three different homogeneous phantoms (10%, 13%, and 16% gelatin concentrations) and ex vivo beef liver tissue showed good agreement between CWS, STL-SWEI, and MM as a function of frequency. For all gelatin phantoms, the maximum accuracy errors were 2.52% and 2.35% using CWS and STL-SWEI, respectively. For the ex vivo beef liver, the maximum accuracy errors were 9.40% and 7.93% using CWS and STL-SWEI, respectively. For lateral resolution, contrast, and CNR, both techniques obtained comparable measurements for vibration frequencies less than 300 Hz (CWS) and distances between the push beams ( ∆x ) between 3 mm and 5.31 mm (STL-SWEI). The results obtained in this study agree over an SWS range of 1-6 m/s. They are expected to agree in perfectly linear, homogeneous, and isotropic materials, but the SWS overlap is not guaranteed in all materials because each of the three methods have unique features.


Assuntos
Técnicas de Imagem por Elasticidade , Fígado/diagnóstico por imagem , Imagens de Fantasmas , Animais , Bovinos , Elasticidade , Fenômenos Eletromagnéticos , Gelatina
SELEÇÃO DE REFERÊNCIAS