J Ultrasound Med ; 40(3): 569-581, 2021 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-33410183

RESUMO

OBJECTIVES: To quantify the bias of shear wave speed (SWS) measurements between different commercial ultrasonic shear elasticity systems and a magnetic resonance elastography (MRE) system in elastic and viscoelastic phantoms. METHODS: Two elastic phantoms, representing healthy through fibrotic liver, were measured with 5 different ultrasound platforms, and 3 viscoelastic phantoms, representing healthy through fibrotic liver tissue, were measured with 12 different ultrasound platforms. Measurements were performed with different systems at different sites, at 3 focal depths, and with different appraisers. The SWS bias across the systems was quantified as a function of the system, site, focal depth, and appraiser. A single MRE research system was also used to characterize these phantoms using discrete frequencies from 60 to 500 Hz. RESULTS: The SWS from different systems had mean difference 95% confidence intervals of ±0.145 m/s (±9.6%) across both elastic phantoms and ± 0.340 m/s (±15.3%) across the viscoelastic phantoms. The focal depth and appraiser were less significant sources of SWS variability than the system and site. Magnetic resonance elastography best matched the ultrasonic SWS in the viscoelastic phantoms using a 140 Hz source but had a - 0.27 ± 0.027-m/s (-12.2% ± 1.2%) bias when using the clinically implemented 60-Hz vibration source. CONCLUSIONS: Shear wave speed reconstruction across different manufacturer systems is more consistent in elastic than viscoelastic phantoms, with a mean difference bias of < ±10% in all cases. Magnetic resonance elastographic measurements in the elastic and viscoelastic phantoms best match the ultrasound systems with a 140-Hz excitation but have a significant negative bias operating at 60 Hz. This study establishes a foundation for meaningful comparison of SWS measurements made with different platforms.


Assuntos
Técnicas de Imagem por Elasticidade , Biomarcadores , Elasticidade , Humanos , América do Norte , Imagens de Fantasmas
2.
Ultraschall Med ; 39(3): 260-283, 2018 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-29879750

RESUMO

As a continuation of parts 1 1 and 2 2, this article discusses artifacts as caused by insufficient temporal resolution, artifacts in color and spectral Doppler sonography, and information regarding artifacts in sonography with contrast agents. There are artifacts that occur in B-mode sonography as well as in Doppler imaging methods and sonography with contrast agents, such as slice thickness artifacts and bow artifacts, shadows, mirroring, and artifacts due to refraction that appear, for example, as double images, because they are based on the same formation mechanisms. In addition, there are artifacts specific to Doppler sonography, such as the twinkling artifact, and method-based motion artifacts, such as aliasing, the ureteric jet, and due to tissue vibration. The artifacts specific to contrast mode include echoes from usually highly reflective structures that are not contrast bubbles ("leakage"). Contrast agent can also change the transmitting signal so that even structures not containing contrast agent are echogenic ("pseudoenhancement"). While artifacts can cause problems regarding differential diagnosis, they can also be useful for determining the diagnosis. Therefore, effective use of sonography requires both profound knowledge and skilled interpretation of artifacts.


Assuntos
Artefatos , Ultrassonografia , Diagnóstico Diferencial , Humanos , Ureter
3.
Artigo em Inglês | MEDLINE | ID: mdl-22254537

RESUMO

Transdermal iontophoresis is an active drug delivery method that has the potential to transform treatment of conditions such as acute pain that require a succession of on-demand metered-dose drug deliveries. However, current monophasic iontophoresis methods fail to meet these requirements due to their inability to halt the passive diffusion of active agents when therapy is not required. We have developed a biphasic iontophoretic system to overcome these limitations. The viability of this system was assessed in an in vitro porcine skin preparation using FeCl(2) (127 Daltons), a charged molecule which can undergo both active and passive transdermal diffusion. The transport properties of the system were modeled using a Fourier Transform-derived optimum estimate transfer function. Using this model, experimental results showed good correlation to predicted values for both cumulative dose (R(2)=0.912, n=10), and density dose (R(2)=0.802, n=10). Results also showed the ability to effectively deliver the compound during active periods while minimizing delivery during inactive periods. While preliminary, our results suggest biphasic iontophoresis is a viable means of delivering on-demand drug therapy while minimizing unwanted off-demand delivery.


Assuntos
Quimioterapia Assistida por Computador/instrumentação , Eletrodos , Iontoforese/instrumentação , Técnicas Analíticas Microfluídicas/instrumentação , Processamento de Sinais Assistido por Computador/instrumentação , Absorção Cutânea/fisiologia , Administração Cutânea , Animais , Desenho de Equipamento , Análise de Falha de Equipamento , Técnicas In Vitro , Suínos
4.
Ultrasonics ; 44 Suppl 1: e43-6, 2006 Dec 22.
Artigo em Inglês | MEDLINE | ID: mdl-17056083

RESUMO

A constant sound speed of 1.54 mm/micros is generally used by ultrasound imaging systems for delay and timing. However, the body's sound speed in-homogeneity can lead to defocusing and increased clutter. To provide an improvement using standard transducers, the sound speed used in delay and timing was computed using different sound speeds. We observed improvement in lateral resolution and clutter in phantom, OB, abdominal, and breast imaging. In OB and abdominal imaging using a 4 MHz curved array, 1.48 mm/micros provided higher image quality in many situations. In breast with an 8 MHz linear array, 1.44 mm/micros provided better images in some cases. To provide an automated way to determine and adjust the sound speed used by the imaging system, an algorithm was developed that determines the sound speed that produces the best overall lateral image quality by analyzing the spatial frequency content in a single B-mode frame of channel data using images reconstructed using various trial sound speeds. The metric produced correlates well with the observed best lateral image quality.


Assuntos
Algoritmos , Artefatos , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Modelos Biológicos , Ultrassonografia/métodos , Simulação por Computador , Humanos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade