Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 54
Filtrar
1.
J Vasc Interv Radiol ; 34(5): 790-798, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-36563933

RESUMO

PURPOSE: To evaluate a software simulating the perfused liver volume from virtual selected embolization points on proximal enhanced cone-beam computed tomography (CT) liver angiography data set using selective cone-beam CT as a reference standard. MATERIALS AND METHODS: Seventy-eight selective/proximal cone-beam CT couples in 46 patients referred for intra-arterial liver treatment at 2 recruiting centers were retrospectively included. A reference selective volume (RSV) was calculated from the selective cone-beam CT by manual segmentation and was used as a reference standard. The virtual perfusion volume (VPV) was then obtained using Liver ASSIST Virtual Parenchyma software on proximal cone-beam CT angiography using the same injection point as for selective cone-beam CT. RSV and VPV were then compared as absolute, relative, and signed volumetric errors (ABSErr, RVErr, and SVErr, respectively), whereas their spatial correspondence was assessed using the Dice similarity coefficient. RESULTS: The software was technically successful in automatically computing VPV in 74 of 78 (94.8%) cases. In the 74 analyzed couples, the median RSV was not significantly different from the median VPV (394 mL [196-640 mL] and 391 mL [192-620 mL], respectively; P = .435). The median ABSErr, RVErr, SVErr, and Dice similarity coefficient were 40.9 mL (19.9-97.7 mL), 12.8% (5%-22%), 9.9 mL (-49.0 to 40.4 mL), and 80% (76%-84%), respectively. No significant ABSErr, RVErr, SVErr, and Dice similarity coefficient differences were found between the 2 centers (P = .574, P = .612, P = .416, and P = .674, respectively). CONCLUSIONS: Perfusion hepatic volumes simulated on proximal enhanced cone-beam CT using the virtual parenchyma software are numerically and spatially similar to those manually obtained on selective cone-beam CT.


Assuntos
Embolização Terapêutica , Neoplasias Hepáticas , Humanos , Neoplasias Hepáticas/terapia , Estudos Retrospectivos , Tomografia Computadorizada de Feixe Cônico/métodos
2.
J Thromb Thrombolysis ; 55(2): 297-303, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-36525155

RESUMO

In this study, we sought to investigate the effectiveness of inferior vena cava (IVC) filter placement in reducing the incidence of venous thromboembolism (VTE) in patients diagnosed with isolated calf deep vein thrombosis (DVT) after an intracranial hemorrhage or intracranial operation. A retrospective chart review (January 2000-December 2019) was performed to identify patients diagnosed with calf DVT after intracranial hemorrhage or intracranial operation. A total of 100 patients met the study criteria and were divided into groups based on treatment: IVC filter placement (n = 22), prophylactic anticoagulation (n = 42), or imaging surveillance (n = 36). Treatment-related complications were identified, and differences between groups in the primary endpoint (VTE occurrence after DVT diagnosis) were assessed using logistic regression. VTE occurred in 15 patients after calf DVT diagnosis. The rate of VTE was higher in the IVC filter group (9/22; 41%) than in the anticoagulation (2/42; 5%; p = 0.002) and surveillance (4/36; 11%; p = 0.013) groups. These treatment effects remained significant after adjustments were made for baseline characteristics (IVC filter vs anticoagulation, p = 0.009; IVC filter vs surveillance, p = 0.019). There was a single occurrence of pulmonary embolism in the surveillance group (3%). A single case of IVC filter thrombus was identified; no anticoagulation-related complications were reported. The findings of this study do not support IVC filter placement as a primary and solitary treatment for isolated calf DVT occurring after intracranial hemorrhage or intracranial operation.


Assuntos
Isquemia Mesentérica , Embolia Pulmonar , Filtros de Veia Cava , Tromboembolia Venosa , Trombose Venosa , Humanos , Tromboembolia Venosa/epidemiologia , Tromboembolia Venosa/etiologia , Tromboembolia Venosa/prevenção & controle , Estudos Retrospectivos , Filtros de Veia Cava/efeitos adversos , Incidência , Isquemia Mesentérica/complicações , Fatores de Risco , Trombose Venosa/terapia , Embolia Pulmonar/etiologia , Hemorragias Intracranianas/etiologia , Hemorragias Intracranianas/complicações , Resultado do Tratamento , Veia Cava Inferior/diagnóstico por imagem
3.
J Vasc Interv Radiol ; 33(9): 1113-1120, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-35871021

RESUMO

Artificial intelligence (AI)-based technologies are the most rapidly growing field of innovation in healthcare with the promise to achieve substantial improvements in delivery of patient care across all disciplines of medicine. Recent advances in imaging technology along with marked expansion of readily available advanced health information, data offer a unique opportunity for interventional radiology (IR) to reinvent itself as a data-driven specialty. Additionally, the growth of AI-based applications in diagnostic imaging is expected to have downstream effects on all image-guidance modalities. Therefore, the Society of Interventional Radiology Foundation has called upon 13 key opinion leaders in the field of IR to develop research priorities for clinical applications of AI in IR. The objectives of the assembled research consensus panel were to assess the availability and understand the applicability of AI for IR, estimate current needs and clinical use cases, and assemble a list of research priorities for the development of AI in IR. Individual panel members proposed and all participants voted upon consensus statements to rank them according to their overall impact for IR. The results identified the top priorities for the IR research community and provide organizing principles for innovative academic-industrial research collaborations that will leverage both clinical expertise and cutting-edge technology to benefit patient care in IR.


Assuntos
Inteligência Artificial , Radiologia Intervencionista , Consenso , Humanos , Pesquisa , Sociedades Médicas
4.
J Vasc Interv Radiol ; 32(8): 1240.e1-1240.e8, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-34332723

RESUMO

Recently developed endovascular techniques to create percutaneous arteriovenous fistulas are an alternative to surgical arteriovenous fistula creation, although there is currently a lack of high-level evidence regarding their creation, maturation, utilization, and long-term function. Recognizing this, the Society of Interventional Radiology Foundation sponsored a Research Consensus Panel and Summit for the prioritization of a research agenda to identify and address the gaps in current knowledge.


Assuntos
Fístula Arteriovenosa , Derivação Arteriovenosa Cirúrgica , Falência Renal Crônica , Fístula Arteriovenosa/diagnóstico por imagem , Fístula Arteriovenosa/terapia , Consenso , Humanos , Pesquisa Interdisciplinar , Falência Renal Crônica/diagnóstico , Falência Renal Crônica/terapia , Diálise Renal , Resultado do Tratamento , Grau de Desobstrução Vascular
5.
J Cell Physiol ; 235(9): 6167-6182, 2020 09.
Artigo em Inglês | MEDLINE | ID: mdl-31975386

RESUMO

Hepatocellular carcinoma (HCC) is a major health problem worldwide and in the United States as its incidence has increased substantially within the past two decades. HCC therapy remains a challenge, primarily due to underlying liver disorders such as cirrhosis that determines treatment approach and efficacy. Activated hepatic stellate cells (A-HSCs) are the key cell types involved in hepatic fibrosis/cirrhosis. A-HSCs are important constituents of HCC tumor microenvironment (TME) and support tumor growth, chemotherapy resistance, cancer cell migration, and escaping immune surveillance. This makes A-HSCs an important therapeutic target in hepatic fibrosis/cirrhosis as well as in HCC. Although many studies have reported the role of A-HSCs in cancer generation and investigated the therapeutic potential of A-HSCs reversion in cancer arrest, not much is known about inactivated or quiescent HSCs (Q-HSCs) in cancer growth or arrest. Here we report that Q-HSCs resist cancer cell growth by inducing cytotoxicity and enhancing chemotherapy sensitivity. We observed that the conditioned media from Q-HSCs (Q-HSCCM) induces cancer cell death through a caspase-independent mechanism that involves an increase in apoptosis-inducing factor expression, nuclear localization, DNA fragmentation, and cell death. We further observed that Q-HSCCM enhanced the efficiency of doxorubicin, as measured by cell viability assay. Exosomes present in the conditioned media were not involved in the mechanism, which suggests the role of other factors (proteins, metabolites, or microRNA) secreted by the cells. Identification and characterization of these factors are important in the development of effective HCC therapy.


Assuntos
Fator de Indução de Apoptose/genética , Carcinoma Hepatocelular/tratamento farmacológico , Células Estreladas do Fígado/metabolismo , Neoplasias Hepáticas/tratamento farmacológico , Apoptose/efeitos dos fármacos , Carcinoma Hepatocelular/genética , Carcinoma Hepatocelular/patologia , Caspases/genética , Linhagem Celular Tumoral , Movimento Celular/efeitos dos fármacos , Proliferação de Células/efeitos dos fármacos , Meios de Cultivo Condicionados/farmacologia , Fragmentação do DNA/efeitos dos fármacos , Doxorrubicina/farmacologia , Resistencia a Medicamentos Antineoplásicos/genética , Células Estreladas do Fígado/química , Humanos , Fígado/efeitos dos fármacos , Fígado/metabolismo , Fígado/patologia , Neoplasias Hepáticas/genética , Neoplasias Hepáticas/patologia , Microambiente Tumoral
6.
J Vasc Interv Radiol ; 31(11): 1866-1873.e2, 2020 11.
Artigo em Inglês | MEDLINE | ID: mdl-33129432

RESUMO

PURPOSE: To compare cellular uptake and cytotoxicity of fluorescein (FL)-labeled polyethylene glycols (PEGs) carrying 2 folate groups (targeted delivery vehicles [TDVs]) to non-PEGylated molecules with 1 or 2 folate groups. MATERIALS AND METHODS: Three PEGylated TDVs and 2 non-PEGylated folic acid (FA)-fluorescein (FL) conjugates (FA-FL and FA-FL-FA) were synthesized. Two triple-negative breast cancer cell lines (MDA-MB-231and MDA-MB-468) were cultured to 70% confluency and incubated for 2 h in a folate-depleted medium. Folate receptor (FR) expression was confirmed by immunocytochemistry. Cellular uptake and cytotoxicity of compounds were measured by flow cytometry. Intracellular localization was confirmed using confocal microscopy. RESULTS: MDA-MB-231 demonstrated 40% more FR staining than MD-MB-468. Intracellular localization of the 2 non-PEGylated molecules (FA-FL and FA-FL-FA) and the 3 PEGylated TDVs was confirmed with confocal microscopy. Cellular uptake was independent of concentration for FA-FL, but there was 26.8% more cytotoxicity at 30 µg/mL compared with no treatment (P ≤ .05). Uptake was > 90% for FA-FL-FA at 10 µg/mL and 30 µg/mL without significant cytotoxicity (P ≤ .005). Cellular uptake was > 80% for all TDVs. The molecule containing monodispersed PEG with Mn = 1,000 g/mol had the highest uptake in both cell lines without cytotoxicity. Maximum toxicity was demonstrated by the molecule containing PEG2,000 only at the highest dose of 30 µg/mL (8.66% ± 3.94% cytotoxicity; cut-off was 20%). CONCLUSIONS: The molecule containing monodispersed PEG with Mn = 1,000 g/mol and 2 FA targeting groups demonstrated better targetability and cellular uptake as a TDV.


Assuntos
Portadores de Fármacos , Ácido Fólico/metabolismo , Polietilenoglicóis/química , Neoplasias de Mama Triplo Negativas/metabolismo , Transporte Biológico , Linhagem Celular Tumoral , Sobrevivência Celular/efeitos dos fármacos , Feminino , Fluoresceína/metabolismo , Corantes Fluorescentes/metabolismo , Receptor 1 de Folato , Ácido Fólico/química , Humanos , Polietilenoglicóis/toxicidade
7.
Skeletal Radiol ; 49(3): 375-382, 2020 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-31377837

RESUMO

OBJECTIVE: While percutaneous osteoplasty is common for the treatment of vertebral fractures, low strength of fixation remains a major challenge for use in metastatic weight-bearing bones. With stent, wire, and cement augmentation, this study explores the feasibility of percutaneous reinforced osteoplasty for use in correcting long bone fractures. MATERIALS AND METHODS: Fifteen explanted swine femora were randomly assigned into three groups. Group 1 (n = 5) was native (intact) bones without any intervention (control), group 2 (n = 5) received cementoplasty, and group 3 (n = 5) received stent and wire scaffolding ("rebar") in addition to cementoplasty. All treatment procedures were performed under fluoroscopic guidance. Mechanical strength of fracture fixation was quantified by peak load to failure, stiffness, work done to fracture, and fatigue testing with four-point bend test. RESULTS: Percutaneous osteoplasty with or without reinforcement was successfully achieved in all specimens. The respective peak load at failure, flexural stiffness, and work done to fracture (mean ± SEM) for group 1 was 2245 ± 168 N, 14.77 ± 1.3 Nm/degree, and 4854 ± 541 Nmm; group 2 was 468 ± 81 N, 3.9 ± 0.5 Nm/degree, and 401 ± 56 Nmm; and group 3 was 594 ± 90 N, 4.42 ± 0.4 Nm/degree, and 522 ± 54 Nmm. The mean cyclic displacement for groups 1, 2, and 3 were 0.15, 0.58, and 0.48 mm, respectively, at 220-240 N loading. CONCLUSIONS: While percutaneous reinforced osteoplasty with stent, wire, and cement augmentation resulted in improved mechanical strength in restored bones, it did not differ significantly from specimens that underwent exclusive cementoplasty. With the improvement of fracture strength, the concept may be applicable for prevention or treatment of pathological fractures.


Assuntos
Neoplasias Ósseas/cirurgia , Cementoplastia/métodos , Fêmur/cirurgia , Fraturas Espontâneas/cirurgia , Animais , Fenômenos Biomecânicos , Modelos Animais de Doenças , Estudos de Viabilidade , Fluoroscopia , Suínos
8.
Vasa ; 49(6): 449-462, 2020 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-32660360

RESUMO

Inferior vena cava (IVC) filter has been used to manage patients with pulmonary embolism and deep venous thrombosis. Its ease of use and the expansion of relative indications have led to a dramatic increase in IVC filter placement. However, IVC filters have been associated with a platitude of complications. Therefore, there exists a need to examine the current indications and identify the patient population at risk. In this paper, we comprehensively reviewed the current indications and techniques of IVC filter placement. Further, we examined the various complications associated with either permanent or retrievable IVC filters. Lastly, we examined the current data on filter retrieval.


Assuntos
Embolia Pulmonar , Filtros de Veia Cava , Remoção de Dispositivo , Humanos , Embolia Pulmonar/etiologia , Embolia Pulmonar/prevenção & controle , Estudos Retrospectivos , Filtros de Veia Cava/efeitos adversos , Veia Cava Inferior/diagnóstico por imagem , Veia Cava Inferior/cirurgia
9.
J Vasc Interv Radiol ; 30(7): 1062-1068.e2, 2019 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-30928484

RESUMO

PURPOSE: To determine access blood flow (ABF) rate using 2D image sequences acquired with digital subtraction angiography (DSA) and fluoroscopy. MATERIALS AND METHODS: A total of 23 patients with known or suspected malfunctioning accesses were imaged using 2 filming modes: DSA at 3 or 6 frames/s (F/s), and fluoroscopy at 10 or 15 pulses/s (P/s). ABF rates were quantified using a bolus tracking method based on cross-correlation algorithm and compared with catheter-based thermal dilution (TD) flow measurements. The indicator-dilution curves were fitted with a gamma-variate (GV) curve fitting model to assess the effect on accuracy. Radiation doses were calculated to examine any increased susceptibility to tissue reactions and stochastic effects. RESULTS: For DSA images, the absolute percent deviations (mean ± standard error of mean) in computed flow vs TD flow measurements at 3 F/s and 6 F/s were 34% ± 4.5% and 20% ± 4.7%, respectively, without curve fitting, and 31% ± 3.3% and 20% ± 4.1%, respectively, with curve fitting. For fluoroscopic images, the deviations at 10 P/s and 15 P/s were 44% ± 7.3% and 68% ± 10.7%, respectively, without curve fitting and 36% ± 6.4% and 48% ± 7.1%, respectively, with curve fitting. The mean peak skin dose and effective dose at 6 F/s were 3.28 mGy and 75 µSv, respectively. CONCLUSIONS: Digital subtraction angiography images obtained at 6 F/s offered the highest accuracy for dialysis access blood flow quantification.


Assuntos
Algoritmos , Angiografia Digital/métodos , Derivação Arteriovenosa Cirúrgica , Falência Renal Crônica/terapia , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Diálise Renal , Grau de Desobstrução Vascular , Idoso , Velocidade do Fluxo Sanguíneo , Feminino , Humanos , Falência Renal Crônica/diagnóstico por imagem , Falência Renal Crônica/fisiopatologia , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Fluxo Sanguíneo Regional , Reprodutibilidade dos Testes , Termodiluição , Fatores de Tempo
10.
J Vasc Interv Radiol ; 28(7): 949-955, 2017 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-28416267

RESUMO

Hepatocellular carcinoma (HCC) is one of the most common cancers worldwide. HCC develops through a multistep process that involves the local tumor microenvironment, intracellular signaling pathways, and altered metabolic system that allows the cancer proliferation. Understanding the mechanisms of tumor development and progression is critical to developing improved therapies aimed at better survival. This article reviews the molecular mechanisms of HCC development and highlights the potential therapeutic targets for treatments.


Assuntos
Carcinoma Hepatocelular/terapia , Neoplasias Hepáticas/terapia , Terapia de Alvo Molecular , Antineoplásicos/uso terapêutico , Biomarcadores Tumorais , Carcinoma Hepatocelular/etiologia , Progressão da Doença , Humanos , Neoplasias Hepáticas/etiologia , Fatores de Risco , Transdução de Sinais , Microambiente Tumoral
11.
J Vasc Interv Radiol ; 28(10): 1371-1377, 2017 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-28689934

RESUMO

PURPOSE: To compare overall survival and toxicities after yttrium-90 (90Y) radioembolization and chemoembolization with drug-eluting embolics (DEE) in patients with infiltrative hepatocellular carcinoma (HCC). MATERIALS AND METHODS: Retrospective review of 50 patients with infiltrative HCC without main portal vein invasion who were treated with 90Y radioembolization (n = 26) or DEE chemoembolization (n = 24) between March 2007 and August 2012 was completed. Infiltrative tumors were defined by cross-sectional imaging as masses that lacked well-demarcated boundaries, and treatment allocations were made by a multidisciplinary tumor board. Median age was 63 years; median tumor diameter was 9.0 cm; and there were no significant differences between groups in performance status, severity of liver disease, or HCC stage. Toxicities were graded by Common Terminology Criteria for Adverse Events v4.03. Overall survival from treatment was assessed by Kaplan-Meier analysis, with analysis of potential predictors of survival with log-rank test. RESULTS: There was no difference in the average number of procedures performed in each treatment group (DEE, 1.5 ± 1.1; 90Y, 1.6 ± 0.5; P = .97), and technical success was achieved in all cases. Abdominal pain (73% vs 33%; P = .004) and fever (38% vs 8%; P = .01) were more frequent after DEE chemoembolization. There was no significant difference in median overall survival between treatment groups after treatment (DEE, 9.9 months; 90Y, 8.1 months; P = .11). CONCLUSIONS: 90Y radioembolization and DEE chemoembolization provided similar overall survival in the treatment of infiltrative HCC without main portal vein invasion. Abdominal pain and fever were more frequent after DEE chemoembolization.


Assuntos
Carcinoma Hepatocelular/terapia , Neoplasias Hepáticas/terapia , Biópsia , Carcinoma Hepatocelular/diagnóstico por imagem , Carcinoma Hepatocelular/radioterapia , Quimioembolização Terapêutica , Feminino , Humanos , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/radioterapia , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Compostos Radiofarmacêuticos , Estudos Retrospectivos , Taxa de Sobrevida , Resultado do Tratamento , Radioisótopos de Ítrio
14.
Semin Dial ; 28(4): E41-7, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-25800550

RESUMO

Translumbar tunneled dialysis catheter (TLDC) is a temporary dialysis access for patients exhausted traditional access for dialysis. While few small studies reported successes with TLDC, additional studies are warranted to understand the short- and long-term patency and safety of TLDC. We conducted a retrospective analysis of adult patients who received TLDC for hemodialysis access from June 2006 to June 2013. Patient demographics, comorbid conditions, dialysis details, catheter insertion procedures and associated complications, catheter patency, and patient survival data were collected. Catheter patency was studied using Kaplan-Meier curve; catheter functionality was assessed with catheter intervals and catheter-related complications were used to estimate catheter safety. There were 84 TLDCs inserted in 28 patients with 28 primary insertions and 56 exchanges. All TLDC insertions were technically successful with good blood flow during dialysis (>300 ml/minute) and no immediate complications (major bleeding or clotting) were noted. The median number of days in place for initial catheter, secondary catheter, and total catheter were 65, 84, and 244 respectively. The catheter patency rate at 3, 6, and 12 months were 43%, 25%, and 7% respectively. The main complications were poor blood flow (40%) and catheter-related infection (36%), which led to 30.8% and 35.9% catheter removal, respectively. After translumbar catheter, 42.8% of the patients were successfully converted to another vascular access or peritoneal dialysis. This study data suggest that TLDC might serve as a safe, alternate access for dialysis patients in short-term who have exhausted conventional vascular access.


Assuntos
Catéteres/efeitos adversos , Diálise Renal/instrumentação , Falha de Equipamento , Feminino , Humanos , Região Lombossacral , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos
15.
BJU Int ; 114(3): 412-7, 2014 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-24325283

RESUMO

OBJECTIVE: To present the outcomes of active surveillance (AS) for renal angiomyolipomas (AMLs) and to assess the clinical features predicting delayed intervention of this treatment option. PATIENTS AND METHODS: We retrospectively reviewed the outcomes of patients diagnosed with AMLs on computed tomography (CT) who were managed with AS at our institution. The AS protocol consisted of 6- and 12-month, then annual follow-up visits, each one including a physical examination and CT imaging. Discontinuation of AS was defined as the need or decision for an active procedure during the follow-up period. Causes of delayed intervention, as well as the type of active treatment (AT), were recorded. Clinical features at presentation of patients failing AS were compared with those who remained under AS at the time of the last follow-up. Predictive factors of delayed intervention were analysed using univariate and multivariate Cox regression models. RESULTS: Overall, 130 patients were included in the analysis, of whom 102 (78.5%) were incidentally diagnosed, while 15 (11.5%) and 13 patients (10%) presented with flank pain and haematuria, respectively. After a mean (sd) follow-up of 49 (40) months, 17 patients (13%) discontinued AS and underwent AT. Patients who underwent delayed intervention were more likely to present with a higher body mass index, larger tumours and symptomatic disease. Angioembolization represented the first-line AT after AS (64.7%), whereas partial nephrectomy was adopted in 29.4% of patients. On the univariate analysis, risk factors for delayed intervention included tumour size ≥4 cm, symptoms at diagnosis, and history of concomitant or contralateral kidney disease. On the multivariate analysis, only tumour size and symptoms remained independently associated with discontinuation of AS. CONCLUSIONS: Tumour size and symptoms at initial presentation were highly predictive of discontinuation of AS in the management of AMLs. Selective angioembolization was the first-line option used for AT after AS was discontinued.


Assuntos
Angiomiolipoma/patologia , Embolização Terapêutica , Dor no Flanco/patologia , Hematúria/patologia , Neoplasias Renais/patologia , Vigilância da População , Esclerose Tuberosa/patologia , Carga Tumoral , Adulto , Angiomiolipoma/epidemiologia , Angiomiolipoma/terapia , Feminino , Seguimentos , Humanos , Achados Incidentais , Neoplasias Renais/epidemiologia , Neoplasias Renais/terapia , Masculino , Pessoa de Meia-Idade , Exame Físico , Guias de Prática Clínica como Assunto , Valor Preditivo dos Testes , Estudos Retrospectivos , Fatores de Risco , Fatores de Tempo , Tomografia Computadorizada por Raios X , Resultado do Tratamento
16.
J Gastrointest Oncol ; 15(1): 356-367, 2024 Feb 29.
Artigo em Inglês | MEDLINE | ID: mdl-38482235

RESUMO

Background: 90Y radioembolization is an established treatment modality for hepatic malignancies. Successful radioembolization requires optimal dose delivery to tumors while minimizing dosages to parenchyma. Post-treatment positron emission tomography (PET)/computed tomography (CT) dosimetry is the established benchmark, whereas PET/magnetic resonance (MR) is an emerging modality. The goal of this study was to assess the intermodality agreement between PET/MR and PET/CT 90Y dosimetry. Methods: In this single-institution study, 18 patients (20 treatment sessions) with a primary or metastatic hepatic malignancy underwent both PET/MR and PET/CT after 90Y radioembolization. Patients were randomized to undergo one modality first, followed by the other. The region of interest was delineated using MR images and tumor and liver dosimetry was calculated. Intermodality agreement was assessed using the Bland-Altman method. A generalized linear model was used to assess the effect of baseline variables on intermodality dose differences. Results: PET/MR underestimated tumor and liver absorbed doses when compared to PET/CT by -3.7% (P=0.042) and -5.8% (P=0.029), respectively. A coverage probability plot demonstrated that 80% and 90% of tumor dose measurements fell within intermodality differences of 11% and 18%, respectively. PET/MR underestimated tumor dose at both low (<1 GBq) and high (>3 GBq) injected activity levels (P<0.001) by -22.3 [standard deviation (SD) =13.5] and -24.3 (SD =18.7), respectively. Conclusions: Although PET/MR significantly underestimated the absorbed dose when compared to PET/CT, the intermodality agreement was high and the degree of underestimation was better than previously reported. Intermodality differences were more pronounced at low and high injected doses. Additional studies are required to assess the clinical implications of these findings.

17.
N Engl J Med ; 362(6): 494-503, 2010 Feb 11.
Artigo em Inglês | MEDLINE | ID: mdl-20147715

RESUMO

BACKGROUND: The leading cause of failure of a prosthetic arteriovenous hemodialysis-access graft is venous anastomotic stenosis. Balloon angioplasty, the first-line therapy, has a tendency to lead to subsequent recoil and restenosis; however, no other therapies have yet proved to be more effective. This study was designed to compare conventional balloon angioplasty with an expanded polytetrafluoroethylene endovascular stent graft for revision of venous anastomotic stenosis in failing hemodialysis grafts. METHODS: We conducted a prospective, multicenter trial, randomly assigning 190 patients who were undergoing hemodialysis and who had a venous anastomotic stenosis to undergo either balloon angioplasty alone or balloon angioplasty plus placement of the stent graft. Primary end points included patency of the treatment area and patency of the entire vascular access circuit. RESULTS: At 6 months, the incidence of patency of the treatment area was significantly greater in the stent-graft group than in the balloon-angioplasty group (51% vs. 23%, P<0.001), as was the incidence of patency of the access circuit (38% vs. 20%, P=0.008). In addition, the incidence of freedom from subsequent interventions at 6 months was significantly greater in the stent-graft group than in the balloon-angioplasty group (32% vs. 16%, P=0.03 by the log-rank test and P=0.04 by the Wilcoxon rank-sum test). The incidence of binary restenosis at 6 months was greater in the balloon-angioplasty group than in the stent-graft group (78% vs. 28%, P<0.001). The incidences of adverse events at 6 months were equivalent in the two treatment groups, with the exception of restenosis, which occurred more frequently in the balloon-angioplasty group (P<0.001). CONCLUSIONS: In this study, percutaneous revision of venous anastomotic stenosis in patients with a prosthetic hemodialysis graft was improved with the use of a stent graft, which appears to provide longer-term and superior patency and freedom from repeat interventions than standard balloon angioplasty. (ClinicalTrials.gov number, NCT00678249.)


Assuntos
Angioplastia com Balão , Derivação Arteriovenosa Cirúrgica , Oclusão de Enxerto Vascular/terapia , Diálise Renal , Stents , Angioplastia com Balão/efeitos adversos , Derivação Arteriovenosa Cirúrgica/métodos , Cateteres de Demora/efeitos adversos , Feminino , Seguimentos , Oclusão de Enxerto Vascular/etiologia , Humanos , Análise de Intenção de Tratamento , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Recidiva , Stents/efeitos adversos , Falha de Tratamento , Grau de Desobstrução Vascular
18.
J Vasc Interv Radiol ; 24(6): 894-900, 2013 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-23566523

RESUMO

PURPOSE: This pilot trial assesses variability of apoptosis and response 1 day after hepatic intraarterial (IA) benzamide riboside (BR) in rodent hepatomas and its correlation to water apparent diffusion coefficient (ADC) and single-quantum (SQ) and triple-quantum-filtered (TQF) sodium-23 ((23)Na) magnetic resonance (MR) imaging. MATERIALS AND METHODS: Sprague-Dawley rats (n = 8) were inoculated with 10(6) N1-S1 cells. IA BR (20 mg/kg) was infused after 14 days. Animals were killed 1 day (n = 4) or 21 days (n = 4) after therapy. Imaging was performed 1 day before and after treatment. Volume was assessed over 2 weeks. Percentage apoptosis was counted from terminal deoxynucleotidyl transferase dUTP nick-end labeling-stained slides at 400×magnification. Kruskal-Wallis tests were used to compare apoptosis, and Wilcoxon signed-rank tests were used to compare MR signal intensity (SI). RESULTS: Apoptosis was marginally greater in tumor than in nontumor (6.7% vs 1.3%; P = .08), varying from 2% to 10%. Before treatment, MR SI was greater in tumor than in nontumor (ADC, 1.18 vs 0.76 [P = .0078]; SQ, 1.20 vs 1.04 [P = .03]; TQF, 0.55 vs 0.34 [P = .03]). After treatment, tumors increased in volume (0.62 vs 0.33; P = .016) variably over 2 weeks. MR SI remained greater in tumor than in nontumor (ADC, 1.20 vs 0.77 [P = .0078]; SQ, 1.76 vs 1.15 [P = .016]; TQF, 0.84 vs 0.49 [P = .03]). SQ and TQF SI increased by 47% (P = .016) and 53% (P = .016) in tumors, whereas ADC did not change. CONCLUSIONS: Apoptosis was marginal and varied from 2% to 10%. Water ADC, SQ, and TQF MR imaging distinguished tumor from nontumor. Changes in water ADC and sodium MR imaging correlated to apoptosis and volume in select cases, but additional animals are needed to validate this trend against tumor growth.


Assuntos
Apoptose/efeitos dos fármacos , Água Corporal/metabolismo , Carcinoma Hepatocelular/tratamento farmacológico , Carcinoma Hepatocelular/metabolismo , Imageamento por Ressonância Magnética/métodos , Nucleosídeos/uso terapêutico , Sódio/metabolismo , Animais , Antineoplásicos/uso terapêutico , Biomarcadores/metabolismo , Carcinoma Hepatocelular/patologia , Linhagem Celular Tumoral , Ratos , Ratos Sprague-Dawley , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Estatística como Assunto , Resultado do Tratamento
20.
Cardiovasc Diagn Ther ; 13(1): 260-264, 2023 Feb 28.
Artigo em Inglês | MEDLINE | ID: mdl-36864967

RESUMO

Dialysis access interventions have undergone significant developments over the last few decades. Angioplasty has been the mainstay of therapy since the early interventions in the 1980s and 1990s, but poor long-term patency and early loss of access has led investigators to assess other devices to treat stenoses associated with dialysis access failure. Multiple retrospective studies of stents for treatment of stenoses that did not respond to angioplasty demonstrated that the long-term outcomes were not improved over angioplasty alone. Cutting balloons have been studied in a prospective randomized fashion but also showed no long-term improvement over angioplasty alone. Prospective randomized trials have demonstrated that stent-grafts have superior primary patency of the access and the target lesions than angioplasty. The purpose of this review is to summarize the current state of knowledge regarding stent and stent graft use in dialysis access failure. We will discuss the early observational data related to stent use in dialysis access failure including the earliest reports of stent use in dialysis access failure. This review will then focus the review on the prospective randomized data that supports the use of stent-grafts in specific areas of access failure. These include venous outflow stenosis related to grafts, cephalic arch stenoses, native fistula intervention, and the use of stent-grafts to revise in-stent restenosis. Each of these applications will be summarized and the current status of the data will be reviewed.

SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa