Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 23
Filtrar
1.
Int Ophthalmol ; 42(3): 1013-1020, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-34709501

RESUMO

PURPOSE: It is well reported that dry eye symptoms can increase after many refractive surgery procedures. This study aims to provide a clinical understanding of the correlation of fluorescein tear film breakup time (FTBUT) with quality of vision (QoV) and dry eye symptoms following small incision lenticule extraction surgery (SMILE). METHODS: Patients electing to have SMILE surgery were subdivided into 2 groups: Group 1 included short preoperative FTBUTs of 3 to 6 seconds (s); Group 2 included long FTBUTs of ≥ 8 s. Uncorrected distance visual acuity, corrected distance visual acuity, manifest refraction, FTBUT, QoV and Ocular Surface Disease Index (OSDI) questionnaires were recorded 1 and 6 months postoperatively. RESULTS: Thirty-nine subjects were included in each group. There was no significant difference in visual outcomes between the 2 groups at both the 1- and 6-month postoperative assessments. FTBUT remained significantly lower in group 1. Oxford staining was initially higher for group 1 at 1 month (P = 0.007), but there was no significant difference at 6 months (P = 0.180). There was no significant difference in QoV or OSDI scores between the 2 groups at both postoperative visits. CONCLUSIONS: Low preoperative FTBUT (3-6 s) does not appear to negatively affect postoperative visual outcomes or results in a greater likelihood of dry eye symptoms and poor ocular surface compared to eyes with a longer preoperative FTBUT. These results suggest that a low preoperative FTBUT does not necessarily increase the likelihood of poor visual acuity, dry eyes symptoms, or poor ocular surface outcomes following SMILE surgery.


Assuntos
Síndromes do Olho Seco , Miopia , Procedimentos Cirúrgicos Refrativos , Síndromes do Olho Seco/diagnóstico , Síndromes do Olho Seco/etiologia , Síndromes do Olho Seco/cirurgia , Humanos , Lasers de Excimer , Miopia/cirurgia , Refração Ocular , Procedimentos Cirúrgicos Refrativos/métodos , Lágrimas
2.
Int Ophthalmol ; 41(12): 3985-3998, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-34546493

RESUMO

PURPOSE: To assess the 1-month and 12-month postoperative visual performance and subjective outcomes following combined implantation of an extended depth of focus (EDOF) intraocular lens (IOL) and a trifocal IOL. METHODS: The study enrolled consecutive patients undergoing refractive lens extraction or cataract surgery with combined implantation of an EDOF IOL (dominant eye) and trifocal IOL. Uncorrected (UDVA) and best-corrected (CDVA) distance visual acuities, uncorrected intermediate (UIVA) and near (UNVA) visual acuities, and subjective questionnaires were evaluated 1 month and 12 months postoperatively. RESULTS: The study enrolled 58 consecutive patients. Binocular UDVA, UIVA and UNVA were - 0.08 ± 0.07 logMAR, 0.15 ± 0.14 logMAR and 0.17 ± 0.11 logMAR at 1 month, compared to - 0.09 ± 0.06 logMAR (P = .323), 0.11 ± 0.10 logMAR (P = .030) and 0.13 ± 0.10 logMAR (P = 0.008) at 12 months. Satisfaction was high with 93.1% of patients fulfilled or more than fulfilled postoperatively, and 84.5% and 86.3% reported spectacle independence for near at the respective postoperative assessments. The mean daytime and nighttime quality of vision (QoV) scores were 9.12 ± 0.94 and 7.88 ± 1.74 at 1 month, compared to 9.24 ± 0.78 (P = .183) and 8.26 ± 1.38 (P = .043) at 12 months. CONCLUSIONS: This IOL combination provides good unaided visual acuity at 1 and 12 months postoperatively, with high functional vision and postoperative satisfaction reported at 1 and 12 months. However, a significant improvement in overall nighttime QoV at the 12 months assessment was found.


Assuntos
Lentes Intraoculares , Facoemulsificação , Óculos , Humanos , Implante de Lente Intraocular , Satisfação do Paciente , Estudos Prospectivos , Desenho de Prótese , Refração Ocular , Visão Binocular
3.
Curr Opin Ophthalmol ; 28(1): 9-15, 2017 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-27828894

RESUMO

PURPOSE OF REVIEW: The manuscript presents a review of recently published studies reporting objective and subjective outcomes and preoperative considerations of asymmetrical multifocal intraocular lenses (IOLs). RECENT FINDINGS: Current publications suggest that asymmetrical multifocal IOLs provide good, distance, intermediate and near vision for cataract and clear lens extraction patients. The contrast sensitivity achieved is similar to monofocal IOLs. Photopic phenomenon such as glare and halos has been reduced through the use of these IOLs leading to better patient satisfaction. Centration plays a critical role and the lack of a gold standard assessment tool has led to a minority of patients experiencing lower quality of vision and side-effects such as glare and hazy vision. The frequency of dissatisfied patients can be minimized by appropriate patient selection. This is achieved by assessing pupil parameters which guides the surgeon to align the IOL accordingly. SUMMARY: Asymmetric multifocal IOLs provide the surgeon with an IOL that achieves excellent visual and refractive outcomes enabling patients to see clearly at a range of distances. Subjectively patients report low levels of photopic phenomena and high levels of spectacle independence resulting in high overall patient satisfaction.


Assuntos
Extração de Catarata , Sensibilidades de Contraste/fisiologia , Lentes Intraoculares , Humanos , Implante de Lente Intraocular , Facoemulsificação , Cuidados Pós-Operatórios , Cuidados Pré-Operatórios , Pseudofacia/fisiopatologia , Acuidade Visual/fisiologia
4.
Am J Ophthalmol ; 266: 26-36, 2024 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-38705551

RESUMO

PURPOSE: To assess whether the use of measured posterior corneal astigmatism (PCA) values improves the prediction accuracy of toric intraocular lens power formulas, compared to predicted PCA values, when the orientation of the steep axis of PCA is non-vertical. DESIGN: Retrospective observational cohort study. METHODS: Four hundred eighteen eyes of 344 patients were included in the study. Prediction errors (PE) for postoperative refractive astigmatism at 4 weeks postoperatively were determined using vector analysis and compared for the following toric intraocular lens power formulas: Barrett Toric with predicted posterior corneal astigmatism (PPCA); Barrett Toric with measured posterior corneal astigmatism (MPCA); EVO Toric PPCA; EVO Toric MPCA; Holladay I with Abulafia-Koch regression. Subgroup analysis compared PEs for eyes with a vertically orientated steep axis of PCA (60-120°) to eyes with a non-vertically orientated steep axis of PCA. SETTING: Cathedral Eye Clinic, Belfast, United Kingdom and Tan Tock Seng Hospital, Singapore. RESULTS: Standard keratometry was with-the-rule in 48% of eyes, while the steep PCA axis was vertically orientated in 91% of eyes. For all eyes, EVO-PPCA had a smaller mean absolute error than Barrett-MPCA, Barrett-PPCA, and Abulafia-Koch (P < .01 for all). EVO-PPCA had the highest percentage of eyes within 0.50D of predicted postoperative astigmatism for eyes with vertical PCA (61%), while EVO-MPCA had the highest percentage for eyes with non-vertical PCA (54%). EVO-MPCA had the smallest centroid error for all eyes, and the subgroups (P < .01 for all). Eyes with non-vertical PCA had a lower percentage within 0.50D than eyes with vertical PCA when using PPCA (43% vs 61%, P = .034), but there was no significant difference between these groups when MPCA is used for eyes with non-vertical PCA (54% vs 61%, P = .40). CONCLUSIONS: When the steep axis of posterior corneal astigmatism is not vertically orientated, the use of measured posterior keratometry values improves prediction accuracy.


Assuntos
Astigmatismo , Córnea , Implante de Lente Intraocular , Lentes Intraoculares , Óptica e Fotônica , Facoemulsificação , Refração Ocular , Acuidade Visual , Humanos , Astigmatismo/fisiopatologia , Astigmatismo/diagnóstico , Estudos Retrospectivos , Masculino , Feminino , Refração Ocular/fisiologia , Idoso , Acuidade Visual/fisiologia , Pessoa de Meia-Idade , Córnea/fisiopatologia , Reprodutibilidade dos Testes , Biometria/métodos , Topografia da Córnea , Pseudofacia/fisiopatologia , Idoso de 80 Anos ou mais
5.
Vision (Basel) ; 8(3)2024 Aug 28.
Artigo em Inglês | MEDLINE | ID: mdl-39311317

RESUMO

A comparison of the accuracy of intraocular lens (IOL) power calculation formulae, including SRK/T, HofferQ, Holladay 1, Haigis, MM, Barrett Universal II (BUII), Emmetropia Verifying Optical (EVO), and AS-OCT ray tracing, was performed. One hundred eyes implanted with either the Rayone EMV RAO200E (Rayner Intraocular Lenses Limited, Worthing, UK) or the Artis Symbiose (Cristalens Industrie, Lannion, France) IOL were included. Biometry was obtained using IOLMaster 700 (Carl Zeiss Meditec AG, Jena, Germany) and MS-39 AS-OCT (CSO, Firenze, Italy). Mean (MAE) and median (MedAE) absolute errors and percentage of eyes within ±0.25D, ±0.50D, ±0.75D, and ±1.00D of the target were compared, with ±0.75D considered a key metric. The highest percentage within ±0.75D was found with MM (96%) followed by the Haigis (94%) for the enhanced monofocal IOL. SRK/T (94%) had the highest percentage within ±0.75D, followed by Holladay 1, MM, BUII, and ray tracing (all 90%) for the multifocal IOL. No statistically significant difference in MAE was found with both IOLs. EVO showed the lowest MAE for the enhanced monofocal and ray tracing for the multifocal IOL. EVO and ray tracing showed the lowest MedAE for the two respective IOLs. A similar performance with high accuracy across formulae was found. MM and ray tracing appear to have similar accuracy to the well-established formulae and displayed a high percentage of eyes within ±0.75D.

6.
J Cataract Refract Surg ; 49(9): 921-928, 2023 09 01.
Artigo em Inglês | MEDLINE | ID: mdl-37291750

RESUMO

PURPOSE: To assess the 3-month and 12-month postoperative visual performance and subjective quality of vision (QoV) after combined implantation of complementary continuous phase multifocal intraocular lenses (IOLs). SETTING: Private practice, United Kingdom. DESIGN: Case series. METHODS: The study enrolled 44 patients undergoing phacoemulsification with implantation of an Artis Symbiose Mid in the dominant eye and an Artis Symbiose Plus in the nondominant eye. Refraction, uncorrected distance visual acuity (UDVA), corrected distance visual acuity, uncorrected intermediate visual acuity (UIVA), uncorrected near visual acuity (UNVA), electronic reading desk, and a QoV questionnaire were evaluated at 3 months and 12 months postoperatively. RESULTS: The mean binocular UDVA was -0.06 ± 0.08 logMAR and -0.07 ± 0.06 logMAR at 3 months and 12 months ( P = .097), respectively. The mean binocular UIVA was 0.03 ± 0.13 logMAR and 0.03 ± 0.10 logMAR ( P = 1.0), respectively. The mean binocular UNVA was 0.07 ± 0.10 logMAR and 0.07 ± 0.08 logMAR ( P = .875), respectively. There was a significant improvement in QoV for both day and night between 3 and 12 months, with a significant reduction in halos at 12 months. Spectacle independence was reported in 93.2% of cases at 12 months. CONCLUSIONS: The Artis Symbiose Mid and Plus IOL combined implantation provided an excellent range of uncorrected vision at 3 and 12 months. There was a significant improvement in QoV and less halos at 12 months. This IOL combination provided very high rates of complete spectacle independence.


Assuntos
Lentes Intraoculares , Lentes Intraoculares Multifocais , Facoemulsificação , Humanos , Implante de Lente Intraocular , Satisfação do Paciente , Desenho de Prótese , Refração Ocular , Visão Binocular
7.
Clin Ophthalmol ; 16: 1883-1891, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35706684

RESUMO

Purpose: To assess the visual and refractive outcomes following exchange of an opacified multifocal intraocular lens (IOL). Patients and Methods: A consecutive series of 37 eyes (31 patients) that underwent IOL exchange between November 2015 and May 2021 were included in this study. The indication for surgery in all cases was opacification of a multifocal IOL. Outcome measures included design and anatomical location of the secondary IOL, intraoperative and postoperative complications, visual acuity and refractive accuracy. Results: An opacified Lentis Mplus multifocal IOL was explanted from all eyes and replaced with a monofocal IOL in 21 eyes (57%) and multifocal IOL in 16 eyes (43%). Secondary IOLs were implanted in the capsular bag or sulcus or were iris-fixated. IOL exchange was performed at a mean interval of 7 years after the primary surgery. Anterior vitrectomy was required for vitreous prolapse in 9 eyes (24%). Mean corrected distance visual acuity (CDVA) postoperatively was -0.02 ± 0.08 logMAR for eyes with a monofocal secondary IOL and 0.02 ± 0.08 logMAR for eyes with a multifocal secondary IOL. Mean refractive prediction error was -0.57 ± 0.67 D in the multifocal-monofocal group and -0.33 ± 0.59 D in the multifocal-multifocal group. Conclusion: An opacified multifocal IOL can be exchanged for a monofocal or multifocal IOL, depending on available capsular support and the patient's desired refractive outcome. Vitreous prolapse requiring anterior vitrectomy is the most common intraoperative complication. An improvement in visual acuity and a low postoperative complication rate were achieved in this cohort of patients.

8.
J Refract Surg ; 36(5): 326-333, 2020 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-32396644

RESUMO

PURPOSE: To evaluate postoperative visual performance and patient-reported outcomes following combined implantation of an extended depth of focus (EDOF) intraocular lens (IOL) and a trifocal IOL. METHODS: The study enrolled consecutive patients undergoing refractive lens extraction or cataract surgery with combined implantation of an EDOF IOL (dominant eye) and a trifocal IOL in the nondominant eye. Uncorrected (UDVA) and corrected (CDVA) distance visual acuities, uncorrected intermediate (UIVA) and near (UNVA) visual acuities, defocus curves, and subjective questionnaires were evaluated 1 month postoperatively. RESULTS: The study enrolled 100 consecutive patients (200 eyes). The postoperative mean binocular UDVA, UIVA, and UNVA were -0.08 ± 0.07, 0.13 ± 0.12, and 0.17 ± 0.11 logMAR, respectively. The percentage of eyes within ±0.50 and ±1.00 diopters of the refractive target was 65% and 96% with EDOF IOLs, and 76% and 99% with trifocal IOLs, respectively. Of all patients, 91% were satisfied or more than satisfied with the procedure, and 87% of patients were spectacle free for near vision. On a scale from 0 (not at all) to 3 (very), mean scores of 0.52 ± 0.83, 0.71 ± 0.83, and 0.34 ± 0.73 were reported for glare, halos, and starbursts. The mean daytime and nighttime Quality of Vision scores were 9.13 ± 0.91 and 7.96 ± 1.57, respectively. CONCLUSIONS: The combination of an EDOF IOL and a trifocal IOL provides good unaided visual acuity for distance and near. This IOL combination provides high postoperative satisfaction and functional vision, but some early visual side effects were reported. [J Refract Surg. 2020;36(5):326-333.].


Assuntos
Percepção de Profundidade/fisiologia , Implante de Lente Intraocular , Lentes Intraoculares Multifocais , Facoemulsificação , Pseudofacia/fisiopatologia , Refração Ocular/fisiologia , Acuidade Visual/fisiologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Satisfação do Paciente , Estudos Prospectivos , Inquéritos e Questionários , Visão Binocular/fisiologia
9.
J Cataract Refract Surg ; 45(2): 236-241, 2019 02.
Artigo em Inglês | MEDLINE | ID: mdl-30573402

RESUMO

A 23-year-old man developed unilateral corneal ectasia after bilateral small-incision lenticule extraction (SMILE). The preoperative corneal topography was normal, with a minimum corneal thickness of 582 µm and 586 µm in the right eye and left eye, respectively. The refractive correction was -3.00 diopters (D) sphere in the right eye and -3.50 D sphere in the left eye. At the 12-month postoperative visit, corneal topography showed early signs of ectasia in the right eye; the ectasia had deteriorated by the 15-month examination. Corneal crosslinking was performed to arrest further progression. At the last examination, the uncorrected distance visual acuity in the right eye was 0.1 logarithm of the minimum angle of resolution (logMAR) and the corrected distance visual acuity, -0.1 logMAR.


Assuntos
Substância Própria/cirurgia , Cirurgia da Córnea a Laser/métodos , Topografia da Córnea/métodos , Lasers de Excimer/uso terapêutico , Miopia/cirurgia , Refração Ocular/fisiologia , Acuidade Visual , Substância Própria/diagnóstico por imagem , Humanos , Masculino , Miopia/diagnóstico , Miopia/fisiopatologia , Tomografia de Coerência Óptica , Adulto Jovem
10.
Stud Health Technol Inform ; 131: 23-38, 2008.
Artigo em Inglês | MEDLINE | ID: mdl-18305320

RESUMO

Telemedicine and telehealth programs are inherently complex compared with their traditional on-site health care delivery counterparts. Relatively few organizations have developed sustainable, multi-specialty telemedicine programs, although single service programs, such as teleradiology and telepsychiatry programs, are common. A number of factors are barriers to the development of sustainable telemedicine and telehealth programs. First, starting programs is often challenging since relatively few organizations have, in house, a critical mass of individuals with the skill sets required to organize and manage a telemedicine program. Therefore, it is necessary to "boot strap" many of the start-up activities using available personnel. Another challenge is to assemble a management team that has time to champion telemedicine and telehealth while dealing with the broad range of issues that often confront telemedicine programs. Telemedicine programs housed within a single health care delivery system have advantages over programs that serve as umbrella telehealth organizations for multiple health care systems. Planning a telemedicine program can involve developing a shared vision among the participants, including the parent organizations, management, customers and the public. Developing shared visions can be a time-consuming, iterative process. Part of planning includes having the partnering organizations and their management teams reach a consensus on the initial program goals, priorities, strategies, and implementation plans. Staffing requirements of telemedicine and telehealth programs may be met by sharing existent resources, hiring additional personnel, or outsourcing activities. Business models, such as the Application Service Provider (ASP) model used by the Arizona Telemedicine Program, are designed to provide staffing flexibility by offering a combination of in-house and out-sourced services, depending on the needs of the individual participating health care organizations. Telemedicine programs should perform ongoing assessments of activities, ranging from service usage to quality of service assessments, to ongoing analyses of financial performance. The financial assessments should include evaluations of costs and benefits, coding issues, reimbursement, account receivables, bad debt and network utilization. Long-range strategic planning for a telemedicine and telehealth program should be carried out on an on-going basis and should include the program's governing board. This planning process should include goal setting and the periodic updating of the program's vision and mission statements. There can be additional special issues for multi-organization telemedicine and telehealth programs. For example, authority management can require the use of innovative approaches tailored to the realities of the organizational structures of the participating members. Inter-institutional relations may introduce additional issues when competing health care organizations are utilizing shared resources. Branding issues are preferably addressed during the initial planning of a multi-organizational telemedicine and telehealth program. Ideally, public policy regarding telemedicine and telehealth within a service region will complement the objectives of telemedicine and telehealth programs within that service area.


Assuntos
Redes de Comunicação de Computadores/organização & administração , Prestação Integrada de Cuidados de Saúde/métodos , Telemedicina/organização & administração , Medicina Baseada em Evidências , Humanos , Telemedicina/métodos , Telemedicina/tendências
11.
PLoS One ; 13(6): e0197503, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29928004

RESUMO

PURPOSE: To highlight the potential shortcomings associated with the current use Rasch analysis for validation of ophthalmic questionnaires, and to present an alternative application of Rasch analysis to derive insights specific to the cohort of patients under investigation. METHODS: An alternative application of Rasch analysis was used to investigate the quality of vision (QoV) for a cohort of 481 patients. Patients received multifocal intraocular lenses and completed a QoV questionnaire one and twelve months post-operatively. The rating scale variant of the polytomous Rasch model was utilized. The parameters of the model were estimated using the joint maximum likelihood estimation. Analysis was performed on data at both post-operative assessments, and the outcomes were compared. RESULTS: The distribution of the location of symptoms altered between assessments with the most annoyed patients completely differing. One month post-operatively, the most prevalent symptom was starbursts compared to glare at twelve months. The visual discomfort from the most annoyed patients is substantially higher at twelve months. The current most advocated approach for validating questionnaires using Rasch analysis found that the questionnaire was "Rasch-valid" one month post-operatively and "Rasch-invalid" twelve months post-operatively. CONCLUSION: The proposed alternative application of Rasch analysis to questionnaires can be used as an effective decision support tool at population and individual level. At population level, this new approach enables one to investigate the prevalence of symptoms across different cohorts of patients. At individual level, the new approach enables one to identify patients with poor QoV over time. This study highlights some of the potential shortcomings associated with the current use of Rasch analysis to validate questionnaires.


Assuntos
Olho/fisiopatologia , Medidas de Resultados Relatados pelo Paciente , Transtornos da Visão/epidemiologia , Idoso , Feminino , Humanos , Lentes Intraoculares , Masculino , Pessoa de Meia-Idade , Satisfação do Paciente , Psicometria , Qualidade de Vida , Inquéritos e Questionários , Transtornos da Visão/patologia
12.
Eye Vis (Lond) ; 5: 7, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29736407

RESUMO

BACKGROUND: To investigate the impact of the orientation of preoperative corneal astigmatism on achieving the postoperative target refraction following monofocal intraocular lens (IOL) implantation. METHODS: This study enrolled 339 eyes who had uneventful cataract surgery or refractive lens exchange (RLE) with subsequent monofocal IOL implantation. Eyes were initially categorized dependent upon axial length and then on the orientation of preoperative anterior corneal astigmatism. Group 1 had against-the-rule (ATR) anterior corneal astigmatism, group 2 had with-the-rule (WTR) anterior corneal astigmatism, and group 3 had oblique (OB) anterior corneal astigmatism. The preoperative corneal astigmatism was determined by the IOLMaster (Carl Zeiss Meditec AG). Postoperative refraction was completed for all eyes, and the results were calculated and compared for the separate groups. RESULTS: In eyes with axial lengths greater than 22.0 mm and less than 25.0 mm there was a significant difference between the magnitude of preoperative corneal astigmatism between groups 2 and 3 with 0.827 ± 0.376 D in group 2, and 0.677 ± 0.387 D in group 3. The mean postoperative spherical equivalent (SE) prediction error was - 0.132 ± 0.475 D in group 1, 0.026 ± 0.497 D in group 2, and - 0.130 ± 0.477 D in group 3. There was a significant difference between groups 1 and 2. There was no significant difference in the magnitude of preoperative corneal astigmatism and postoperative SE prediction error between the anterior corneal astigmatism orientation groups in eyes with axial lengths of less than or equal to 22.0 mm and greater than or equal to 25.0 mm. CONCLUSIONS: The orientation of preoperative anterior corneal astigmatism significantly affected the postoperative biometry prediction error in eyes with astigmatism of 1.75 D or less in eyes with the axial length between 22.0 mm and 25.0 mm. However, the results were not clinically significant.

13.
J Cataract Refract Surg ; 43(11): 1420-1429, 2017 11.
Artigo em Inglês | MEDLINE | ID: mdl-29223231

RESUMO

PURPOSE: To evaluate the influences of preoperative pupil parameters on the visual outcomes of the SBL-3, a rotationally asymmetric multifocal intraocular lens (IOL) with a surface-embedded near segment. SETTING: Cathedral Eye Clinic, Belfast, Northern Ireland, United Kingdom. DESIGN: Retrospective comparative case series. METHODS: Postoperatively, patients divided into 4 groups according to their pupil size as follows: Group A: 2.50 to 2.99 mm, Group B: 3.00 to 3.50 mm, Group C: 3.51 to 4.00 mm, and Group D: 4.01 to 4.50 mm. The uncorrected distance (UDVA), intermediate (UIVA), and near (UNVA) visual acuities, IOL centration and tilt, and quality of vision (QoV) questionnaires were compared between the 4 groups for 18 months postoperatively. RESULTS: The study comprised 90 patients (180 eyes). The mean preoperative pupil (photopic and mesopic) diameter was 4.3 mm ± 0.3 (SD) and 5.6 ± 1.4 mm, respectively, which decreased to 3.8 ± 0.7 mm and 4.9 ± 1.2 mm, respectively, at 18 months. Eighteen months postoperatively, both photopic and mesopic pupil groups had a statistically significant reduction in size from preoperative levels. No significant differences in UDVA, UIVA, and UNVA were found between the groups (P > .001). Significant differences in the QoV questionnaire day scores and night scores were found between the 4 groups (P < .001). CONCLUSIONS: The rotationally asymmetric multifocal IOL provided excellent optical performance during 18-months follow-up. The preoperative photopic pupil is an important parameter for consideration of this type of IOL because smaller pupils have a significant negative subjective impact on QoV.


Assuntos
Lentes Intraoculares Multifocais , Acuidade Visual , Visão de Cores , Humanos , Estudos Retrospectivos
14.
J Cataract Refract Surg ; 43(5): 633-638, 2017 05.
Artigo em Inglês | MEDLINE | ID: mdl-28602324

RESUMO

PURPOSE: To assess the 3-month and 12-month postoperative visual performance and subjective patient satisfaction after refractive lens exchange (RLE) with implantation of a rotationally asymmetric multifocal intraocular lens (IOL). SETTING: Cathedral Eye Clinic, Belfast, United Kingdom. DESIGN: Prospective case series. METHODS: The refraction, uncorrected (UDVA) and corrected distance visual acuities, uncorrected intermediate (UIVA) and near (UNVA) visual acuities, distance-corrected intermediate and near visual acuities, and a quality of vision (QoV) questionnaire were evaluated 3 months and 12 months after implantation of an SBL-3 IOL. RESULTS: The study enrolled 100 eyes of 50 patients. The mean monocular UDVA was -0.02 logarithm of minimum angle of resolution (logMAR) ± 0.12 (SD) 3 months postoperatively and -0.01 ± 0.10 logMAR at 12 months (P = .393). The mean monocular UIVA was 0.39 ± 0.11 logMAR and 0.41 ± 0.12 logMAR, respectively (P = .06). The mean monocular UNVA was 0.12 ± 0.13 logMAR and 0.14 ± 0.12 logMAR, respectively (P = .077). The mean QoV score was 8.26 ± 1.16 at 3 months with a significant improvement at 12 months, at which time the mean QoV score was 8.84 ± 1.08 (P ≤ .001). CONCLUSIONS: This asymmetric multifocal IOL provided excellent unaided vision with no significant difference in near, intermediate, and distance vision 3 months and 12 months postoperatively. However, there was a significant improvement in subjective outcomes at the second postoperative assessment, during which patients reported a significantly better QoV score and less blurred vision.


Assuntos
Implante de Lente Intraocular , Lentes Intraoculares , Satisfação do Paciente , Humanos , Estudos Prospectivos , Erros de Refração , Acuidade Visual
15.
J Cataract Refract Surg ; 43(8): 1020-1026, 2017 08.
Artigo em Inglês | MEDLINE | ID: mdl-28917400

RESUMO

PURPOSE: To compare the 12-month postoperative quality of vision and visual performance of 2 different refractive rotationally asymmetric multifocal intraocular lenses (IOLs). SETTING: Cathedral Eye Clinic, Belfast, Northern Ireland, United Kingdom. DESIGN: Retrospective case series. METHODS: Refractive lens exchange (RLE) patients were divided into 2 groups. Group A comprised eyes receiving a Lentis Mplus LS-312 MF30 IOL and Group B, eyes receiving a Lenstec SBL-3 IOL. Refraction, uncorrected (UDVA) and corrected distance visual acuities, uncorrected intermediate (UIVA) and near (UNVA) visual acuities, distance-corrected intermediate and near (DCNVA) visual acuities, and quality of vision were evaluated preoperatively and up to 12 months postoperatively. RESULTS: Each group comprised 90 eyes. Both groups had a high level of quality of vision 12 months postoperatively with no significant difference between the 2 groups (P = .919). There was no significant between-group difference in mean monocular and binocular UDVA, monocular UIVA, or monocular UNVA. Group B had statistically significantly better mean monocular DCNVA (P = .049), binocular UNVA (P = .011), and binocular DCNVA (P = .035). Group B had a higher percentage of complete spectacle independence. CONCLUSIONS: Both refractive rotationally asymmetric multifocal IOLs provided an excellent level of quality of vision 12 months postoperatively. Both IOL models restored distance, intermediate, and near visual function; however the IOLs in Group B provided better near visual performance.


Assuntos
Implante de Lente Intraocular , Lentes Intraoculares Multifocais , Refração Ocular , Acuidade Visual , Humanos , Lentes Intraoculares
16.
J Refract Surg ; 32(7): 494-6, 2016 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-27400082

RESUMO

PURPOSE: To report improved visual outcome after rotation of an asymmetrical multifocal intraocular lens (IOL). METHODS: Case report. RESULTS: A 58-year-old patient underwent bilateral phacoemulsification with asymmetrical multifocal IOL implantation. Postoperative uncorrected distance visual acuity (UDVA) was 0.0 logMAR (20/20 Snellen) and uncorrected near visual acuity was 0.0 logMAR (20/20 Snellen) in both eyes. Quality of vision questionnaire scores for day and night were 5 and 7, respectively. The center of the multifocal IOL in the dominant eye was initially found to be 0.2 mm superotemporally displaced, increasing the percentage area of 'near-add' compared to 'distance-add' within the physiological pupil. Rotation of this IOL 120° clockwise greatly improved the IOL centration within the pupil center and resulted in an immediate improvement in UDVA to -0.1 logMAR (20/16 Snellen) and quality of vision questionnaire scores to 8 and 9, respectively. CONCLUSIONS: Assessment of the centration of an asymmetrical multifocal IOL is important, particularly if there are dysphotoptic or other visual complaints. [J Refract Surg. 2016;32(7):494-496.].


Assuntos
Implante de Lente Intraocular , Lentes Intraoculares , Facoemulsificação , Pseudofacia/fisiopatologia , Rotação , Transtornos da Visão/reabilitação , Acuidade Visual/fisiologia , Humanos , Masculino , Pessoa de Meia-Idade , Satisfação do Paciente , Reoperação , Inquéritos e Questionários , Transtornos da Visão/fisiopatologia
17.
J Cataract Refract Surg ; 42(8): 1126-34, 2016 08.
Artigo em Inglês | MEDLINE | ID: mdl-27531287

RESUMO

PURPOSE: To determine the degree of tolerance toward different magnitudes of residual refractive astigmatism and corneal astigmatism and the angles of corneal astigmatism after implantation of an asymmetric multifocal intraocular lens (IOL). SETTING: Cathedral Eye Clinic, Belfast, United Kingdom. DESIGN: Retrospective comparative case series. METHODS: The study enrolled patients having refractive lens exchange and implantation of a Lentis Mplus LS-312 MF30 IOL. Uncorrected (UDVA) and corrected distance visual acuities, uncorrected near and intermediate visual acuities, and quality-of-vision questionnaires were evaluated. Groups were categorized based on the magnitude of refractive astigmatism and corneal residual astigmatism. Refractive astigmatism of less than 0.50 diopter (D) and more than 0.50 D and corneal astigmatism of 0.50 D or less, 0.51 to 0.75 D, 0.76 to 1.00 D, and more than 1.00 D were categorized. RESULTS: The study comprised 117 patients (234 eyes). There was a significant difference in UDVA (P = .003), refractive sphere (P = .001), and defocus equivalent (P ≤ .001) between the residual refractive astigmatism groups; however, there was no difference in quality of vision (P = .28). The same was found for corneal astigmatism with UDVA (P ≤ .001) and quality of vision (P = .16). The angle of corneal astigmatism in relation to IOL placement did not statistically affect postoperative outcomes. CONCLUSIONS: The IOL appeared to subjectively tolerate residual astigmatism well despite a statistically significant difference in UDVA with higher magnitudes of residual astigmatism. The angle of residual corneal astigmatism in relation to IOL placement did not have a significant effect on postoperative outcomes. FINANCIAL DISCLOSURE: None of the authors has a financial or proprietary interest in any material or method mentioned.


Assuntos
Implante de Lente Intraocular , Lentes Intraoculares , Facoemulsificação , Astigmatismo , Humanos , Satisfação do Paciente , Estudos Prospectivos , Refração Ocular , Estudos Retrospectivos , Reino Unido
18.
J Cataract Refract Surg ; 42(12): 1721-1729, 2016 12.
Artigo em Inglês | MEDLINE | ID: mdl-28007103

RESUMO

PURPOSE: To compare the postoperative quality of vision between different bilateral placements of near segments of rotationally asymmetric refractive multifocal intraocular lenses (IOLs) and to determine how this affects visual performance. SETTING: Cathedral Eye Clinic, Belfast, Northern Ireland, United Kingdom. DESIGN: Retrospective comparative case series. METHODS: The study enrolled consecutive patients having refractive lens exchange and implantation of rotationally asymmetric multifocal IOLs. Group 1 received bilateral SBL-3 IOLs and Group 2 received bilateral Lentis Mplus LS-312 MF30 IOLs, with the near segments placed inferonasally in each group. Group 3 received a Lentis Mplus LS-312 MF20 IOL in the dominant eye with the near segment positioned superotemporal and a Lenstec SBL-3 IOL positioned inferonasally in the fellow eye. Binocular uncorrected (UDVA) and corrected distance visual acuities, binocular uncorrected near (UNVA) and intermediate (UIVA) visual acuities, binocular distance-corrected near and intermediate visual acuities, and quality of vision were evaluated over 3 months postoperatively. RESULTS: The study enrolled 180 patients (360 eyes). There was no significant difference between the groups in binocular UDVA, UIVA, and UNVA; however, there was a significant difference between the groups in quality of vision (P ≤ .001). Group 3 had significantly better overall quality of vision. CONCLUSION: When implanting rotationally asymmetric multifocal IOLs, a combination of superotemporal placement of the near segment (+2.00 diopter [D] addition [add]) in the dominant eye with inferonasal placement of the near segment (+3.00 D add) in the fellow eye yielded consistent, high overall quality of vision and uncorrected visual acuity. FINANCIAL DISCLOSURE: None of the authors has a financial or proprietary interest in any material or method mentioned.


Assuntos
Implante de Lente Intraocular , Lentes Intraoculares Multifocais , Acuidade Visual , Sensibilidades de Contraste , Humanos , Lentes Intraoculares , Facoemulsificação , Desenho de Prótese , Pseudofacia , Estudos Retrospectivos , Reino Unido
19.
J Telemed Telecare ; 11(8): 397-402, 2005.
Artigo em Inglês | MEDLINE | ID: mdl-16356313

RESUMO

The Arizona Telemedicine Program (ATP) was established in 1996 when state funding was provided to implement eight telemedicine sites. Since then the ATP has expanded to connect 55 health-care organizations through a membership programme formalized through legal contracts. The ATP's membership model is based on an application service provider (ASP) concept, whereby organizations can share services at lower cost; that is, the ATP acts as a broker for services. The membership fee schedule is flexible, allowing clients to purchase only those services desired. An annual membership fee is paid by every user, based on the services requested. The membership programme income has provided a steady revenue stream for the ATP. The membership-derived revenue represented 30% of the ATP's 2.6 million dollars total income during fiscal year 2003/04.


Assuntos
Atenção à Saúde/organização & administração , Desenvolvimento de Programas , Telemedicina/organização & administração , Arizona , Atenção à Saúde/economia , Humanos , Modelos Econômicos , Serviços de Saúde Rural/organização & administração , Telemedicina/economia
20.
J Cataract Refract Surg ; 45(10): 1524-1525, 2019 10.
Artigo em Inglês | MEDLINE | ID: mdl-31564336
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa