Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
1.
Ann Thorac Surg ; 76(1): 276-7, 2003 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-12842559

RESUMO

We present a case of left main coronary arterial lesion in a 62-year-old man who had undergone mitral valve replacement and microwave epicardial ablation. On postoperative day 90, the patient had an anterior myocardial infarction. The coronary angiography displayed the diagnosis of the left main trunk lesion. A myocardial revascularization was urgently performed, the postoperative course was uneventful, and the patient was in sinus rhythm. The left atrial epicardial ablation represents the ultimate step in the surgical treatment of chronic atrial fibrillation; nevertheless, the left main trunk lesion may occur as an extremely severe complication. The incorrect placement of the microwave probe may be responsible for the development of critical coronary artery stenosis.


Assuntos
Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Próteses Valvulares Cardíacas , Micro-Ondas/efeitos adversos , Estenose da Valva Mitral/cirurgia , Infarto do Miocárdio/etiologia , Fibrilação Atrial/diagnóstico , Angiografia Coronária , Ponte de Artéria Coronária/métodos , Vasos Coronários/lesões , Seguimentos , Humanos , Masculino , Micro-Ondas/uso terapêutico , Pessoa de Meia-Idade , Estenose da Valva Mitral/complicações , Estenose da Valva Mitral/diagnóstico , Infarto do Miocárdio/diagnóstico por imagem , Infarto do Miocárdio/cirurgia , Complicações Pós-Operatórias/diagnóstico , Complicações Pós-Operatórias/cirurgia , Reoperação , Medição de Risco , Resultado do Tratamento
2.
Tex Heart Inst J ; 41(4): 443-4, 2014 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-25120404

RESUMO

Percutaneous closure of the left atrial appendage (LAA) is a new approach to the prevention of cardioembolic events in patients with atrial fibrillation. We implanted an LAA occlusion device (Amplatzer™ Cardiac Plug) in a 70-year-old woman via a transseptal approach. Upon her discharge from the hospital, a transthoracic echocardiogram showed stable anchoring of the device; 6 months after implantation, a routine transthoracic echocardiogram revealed migration of the occluder into the left ventricular outflow tract, in the absence of symptoms. We surgically removed the device from the mitral subvalvular apparatus and closed the LAA with sutures. This case shows that percutaneous LAA occlusion can result in serious adverse events, including device migration in the absence of signs or symptoms; therefore, careful follow-up monitoring is mandatory.


Assuntos
Apêndice Atrial , Fibrilação Atrial/terapia , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/instrumentação , Migração de Corpo Estranho/etiologia , Dispositivo para Oclusão Septal , Idoso , Doenças Assintomáticas , Apêndice Atrial/fisiopatologia , Apêndice Atrial/cirurgia , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/fisiopatologia , Procedimentos Cirúrgicos Cardíacos , Remoção de Dispositivo , Feminino , Migração de Corpo Estranho/diagnóstico , Migração de Corpo Estranho/cirurgia , Humanos , Desenho de Prótese , Técnicas de Sutura , Resultado do Tratamento
3.
Tex Heart Inst J ; 39(5): 744-6, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-23109784

RESUMO

We describe the performance, in one surgical session, of bilateral pulmonary endarterectomy and a button-technique Bentall operation in a 68-year-old man. The patient had chronic thromboembolic pulmonary hypertension and an ascending aortic aneurysm with moderate aortic regurgitation. The procedures were concurrently completed during short periods of systemic circulatory arrest, with antegrade cerebral perfusion maintained through the brachiocephalic artery at a flow rate of 10 mL/min/kg. The patient's cerebral perfusion was monitored with use of near-infrared spectroscopy, to prevent symmetric bilateral values from falling below 20% of the base value. The patient experienced no multiorgan failure or neurologic sequelae and, by the 6th postoperative day, improved from New York Heart Association functional class IV to class I.The reliable maintenance of continuous antegrade cerebral perfusion made the lengthy combined operation feasible, with low risk. The use of near-infrared spectroscopy enabled real-time monitoring of the patient's cerebral blood flow. Our experience shows the possibility of safely performing lengthy or multiple procedures in one surgical session.


Assuntos
Aneurisma Aórtico/cirurgia , Insuficiência da Valva Aórtica/cirurgia , Implante de Prótese Vascular , Endarterectomia , Implante de Prótese de Valva Cardíaca , Hipertensão Pulmonar/cirurgia , Artéria Pulmonar/cirurgia , Idoso , Aneurisma Aórtico/complicações , Aneurisma Aórtico/diagnóstico , Aneurisma Aórtico/fisiopatologia , Insuficiência da Valva Aórtica/complicações , Insuficiência da Valva Aórtica/diagnóstico , Insuficiência da Valva Aórtica/fisiopatologia , Ponte Cardiopulmonar , Circulação Cerebrovascular , Hipertensão Pulmonar Primária Familiar , Parada Cardíaca Induzida , Humanos , Hipertensão Pulmonar/complicações , Hipertensão Pulmonar/diagnóstico , Hipertensão Pulmonar/fisiopatologia , Hipotermia Induzida , Masculino , Monitorização Intraoperatória/métodos , Perfusão/métodos , Artéria Pulmonar/fisiopatologia , Espectroscopia de Luz Próxima ao Infravermelho , Resultado do Tratamento
4.
Transfusion ; 44(7): 1013-8, 2004 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-15225241

RESUMO

BACKGROUND: Chronic ulcers can benefit from topical treatment with growth factors (GFs). PLT gel provides tissue regeneration-inducing GFs. The aim of this study was to verify the effectiveness of autologous PLT gel in the treatment of nonhealing skin lesions. STUDY DESIGN AND METHODS: PLT gel was produced by treating PLTs with autologous thrombin. Two groups of patients were investigated: patients with dehiscent sternal wounds and patients with necrotic skin ulcers. Patients treated with PLT gel were retrospectively compared with patients having similar lesions but undergoing conventional treatment. The clinical endpoints of the study were the healing rate, the length of hospital stay, and/or the time required to bring about adequate tissue regeneration in order to undergo reconstructive plastic surgery. RESULTS: In patients with treated dehiscent sternal wounds the healing rate (3.5 vs. 6.0 wks, p = 0.0002) and hospital stay (31.5 vs. 52.5 days, p < 0.0001) were significantly reduced. Patients with treated necrotic skin ulcers required a notably shorter time to have surgery (median 15.0 vs. 35.5 wks, p < 0.0001). Neither adverse reactions nor in-situ recurrences were observed. CONCLUSIONS: Patients with chronic unhealing wounds showed substantial improvement when treated with PLT gel lesion dressings.


Assuntos
Plaquetas/fisiologia , Úlcera Cutânea/terapia , Cicatrização , Idoso , Feminino , Géis , Humanos , Masculino , Pessoa de Meia-Idade , Necrose , Projetos Piloto , Estudos Retrospectivos , Esterno/cirurgia
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa