Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
1.
Acta Orthop ; 82(6): 685-91, 2011 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-22066559

RESUMO

BACKGROUND AND PURPOSE: To try to improve the outcome of our TKAs, we started to use the CKS prosthesis. However, in a retrospective analysis this design tended to give worse results. We therefore conducted a randomized, controlled trial comparing this CKS prosthesis and our standard PFC prosthesis. Because many randomized studies between different TKA concepts generally fail to show superiority of a particular design, we hypothesized that these seemingly similar designs would not lead to any difference in clinical outcome. PATIENTS AND METHODS: 82 patients (90 knees) were randomly allocated to one or other prosthesis, and 39 CKS prostheses and 38 PFC prostheses could be followed for mean 5.6 years. No patients were lost to follow-up. At each follow-up, patients were evaluated clinically and radiographically, and the KSS, WOMAC, VAS patient satisfaction scores and VAS for pain were recorded. RESULTS: With total Knee Society score (KSS) as primary endpoint, there was a difference in favor of the PFC group at final follow-up (p = 0.04). Whereas there was one revision in the PFC group, there were 6 revisions in the CKS group (p = 0.1). The survival analysis with any reoperation as endpoint showed better survival in the PFC group (97% (95% CI: 92-100) for the PFC group vs. 79% (95% CI: 66-92) for the CKS group) (p = 0.02). INTERPRETATION: Our hypothesis that there would be no difference in clinical outcome was rejected in this study. The PFC system showed excellent results that were comparable to those in previous reports. The CKS design had differences that had considerable negative consequences clinically. The relatively poor results have discouraged us from using this design.


Assuntos
Artroplastia do Joelho , Prótese do Joelho , Idoso , Idoso de 80 Anos ou mais , Artroplastia do Joelho/efeitos adversos , Artroplastia do Joelho/métodos , Feminino , Seguimentos , Humanos , Articulação do Joelho/diagnóstico por imagem , Prótese do Joelho/efeitos adversos , Masculino , Pessoa de Meia-Idade , Avaliação de Resultados em Cuidados de Saúde , Desenho de Prótese , Falha de Prótese , Radiografia , Amplitude de Movimento Articular , Reoperação , Resultado do Tratamento
2.
Acta Orthop ; 81(3): 337-43, 2010 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-20450422

RESUMO

BACKGROUND AND PURPOSE: In the reconstruction of unicondylar femoral bone defects with morselized bone grafts in revision total knee arthroplasty, a stem extension appears to be critical to obtain adequate mechanical stability. Whether stability is still assured by this reconstruction technique in bicondylar defects has not been assessed. The disadvantage of relatively stiff stem extensions is that bone resorption is promoted due to stress shielding. We therefore designed a stem that would permit axial sliding movements of the articulating part relative to the intramedullary stem. METHODS: This stem was used in the reconstruction with impaction bone grafting (IBG) of 5 synthetic distal femora with a bicondylar defect. A cyclically axial load was applied to the prosthetic condyles to assess the stability of the reconstruction. Radiostereometry was used to determine the migrations of the femoral component with a rigidly connected stem, a sliding stem, and no stem extension. RESULTS: We found a stable reconstruction of the bicondylar femoral defects with IBG in the case of a rigidly connected stem. After disconnecting the stem, the femoral component showed substantially more migrations. With a sliding stem, rotational migrations were similar to those of a rigidly connected stem. However, the sliding stem allowed proximal migration of the condylar component, thereby compressing the IBG. INTERPRETATION: The presence of a functional stem extension is important for the stability of a bicondylar reconstruction. A sliding stem provides adequate stability, while stress shielding is reduced because compressive contact forces are still transmitted to the distal femoral bone.


Assuntos
Artroplastia do Joelho , Transplante Ósseo , Artroplastia do Joelho/efeitos adversos , Artroplastia do Joelho/métodos , Fêmur/fisiologia , Fêmur/cirurgia , Prótese de Quadril , Humanos , Fotogrametria , Falha de Prótese , Reoperação , Rotação
3.
Arch Orthop Trauma Surg ; 129(10): 1361-5, 2009 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-19099309

RESUMO

INTRODUCTION: It is fascinating for both the patient and the surgeon to predict the outcome of a TKA at an early stage. Satisfaction after TKA is primarily determined by the preoperative expectations of the patient. The purpose of this study was to investigate if the peri-operative expectations of the surgeon predicted the outcome of a TKA. PATIENTS AND METHODS: A prospective study of 53 primary TKAs was performed. Preoperatively, the surgeon described the assessment of the difficulty of the TKA on a VAS. Immediately postoperative, the surgeon gave his satisfaction VAS about the procedure. After 1 year the surgeon's satisfaction VAS, the patient's satisfaction VAS and the KSCRS were determined. RESULTS: The Spearman's correlation coefficients between the preoperative difficulty assessment, the immediate postoperative satisfaction and the outcome measurements after 1 year were all very poor (-0.01 to 0.23). CONCLUSIONS: The outcome of a TKA depends on multiple factors. Both the surgeon's preoperative assessment of the difficulty and the surgeon's immediate postoperative satisfaction do not independently predict the outcome of a TKA.


Assuntos
Artroplastia do Joelho , Atitude do Pessoal de Saúde , Idoso , Idoso de 80 Anos ou mais , Feminino , Previsões , Humanos , Masculino , Pessoa de Meia-Idade , Medição da Dor , Prognóstico , Estudos Prospectivos , Resultado do Tratamento
4.
Acta Orthop ; 78(1): 123-7, 2007 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-17453403

RESUMO

BACKGROUND: A medialization of the femoral component in a total knee arthroplasty (TKA) causes abnormal patellar tracking, which could result in patellar instability, pain, wear, and failure. Previous reports defined medialization in relation to the neutral position of the femoral component, but omitted to compare it to the anatomical position of the trochlea. We assessed intraoperatively whether there is a systematic error of the position of the prosthetic groove relative to the anatomical trochlea. MATERIAL AND METHODS: A special instrument was developed to measure consecutively the mediolateral position of the anatomical trochlea and the mediolateral position of the prosthetic groove. 3 experienced knee surgeons determined the mediolateral error of the prosthetic groove in primary TKAs in 61 patients. RESULTS: There was a significant medial error of the prosthetic groove relative to the preoperative position of the trochlea, with a mean medial error of 2.5 mm (SD 3.3) INTERPRETATION: Our findings indicate that the trochlea is medialized by TKA. Because a conscious medialization of the femoral component in a TKA produces abnormal patellar tracking patterns, further investigations will be needed to analyze the clinical consequences of this medialization of the trochlea.


Assuntos
Artroplastia do Joelho , Patela , Artroplastia do Joelho/efeitos adversos , Fenômenos Biomecânicos , Humanos , Prótese do Joelho/efeitos adversos , Variações Dependentes do Observador , Patela/patologia , Patela/fisiopatologia , Estudos Prospectivos , Desenho de Prótese , Amplitude de Movimento Articular
5.
Clin Orthop Relat Res ; (421): 143-50, 2004 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-15123939

RESUMO

In a one-surgeon study the clinical and radiographic results of 30 cementless bipolar hip prostheses in 24 patients younger than 55 years were evaluated. Eleven noncoated prostheses (Noncoated Group) and 19 hydroxyapatite-coated prostheses (Hydroxyapatite Group) were compared after a mean followup of 10.4 years. The Harris hip score increased from a preoperative average of 41 points to 76 points at final followup (Noncoated Group, 70 points; Hydroxyapatite Group, 80 points). Thigh or groin pain was present in 15 patients (16 hips) (Noncoated Group, 55%; Hydroxyapatite Group, 53%). Radiographically, subsidence was the major problem at the noncoated prostheses (Noncoated Group, 91%; Hydroxyapatite Group, 5%), whereas osteolysis mainly was seen at the hydroxyapatite-coated prostheses (Noncoated Group, 18%; Hydroxyapatite Group, 89%). The obtained aseptic revision rate of 27% (Noncoated Group, 27%; Hydroxyapatite Group, 26%) is too high to use this implant in young patients. The large amounts of polyethylene wear debris generated by the bipolar system play an important role in this limited success. In the initially well-fixed hydroxyapatite-coated prostheses the sealing effect of a hydroxyapatite coating creates high concentrations of polyethylene in the limited joint space, resulting in massive proximal femoral osteolysis. Consequently, a hydroxyapatite coating introduces a new failure mechanism. Therefore, hydroxyapatite does not improve the outcome of a cementless bipolar hemiarthroplasty in the long-term.


Assuntos
Artroplastia de Quadril , Materiais Revestidos Biocompatíveis , Durapatita , Prótese de Quadril , Osteoartrite do Quadril/cirurgia , Falha de Prótese , Adolescente , Adulto , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Osteoartrite do Quadril/diagnóstico por imagem , Estudos Prospectivos , Desenho de Prótese , Radiografia , Fatores de Tempo , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa