Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
1.
Int J Oral Maxillofac Surg ; 48(6): 779-786, 2019 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-30595235

RESUMO

The aim of this study was to evaluate whether a correlation exists between temporal bone pneumatization and the morphology of the articular eminence and glenoid fossa. A sample of 100 cone beam computed tomography scans was used, for a total of 200 temporomandibular joints (TMJ). Paracoronal and parasagittal images of the TMJ were evaluated by two examiners. For all TMJ, pneumatization was classified in the mid-lateral direction using a score of 0 or 1, and in the anteroposterior direction using a score ranging from 0 to 3. The inclination and height of the articular eminence and the thickness of the roof of the glenoid fossa were obtained. Pneumatization was found in the mid-lateral direction in 83.5% of the cases and in the anteroposterior direction in 88%. The age of the patient and side did not influence the prevalence or degree of pneumatization (P=0.051-0.953), but female patients showed more pneumatization in the mid-lateral direction than male patients (P=0.014). The presence of pneumatization did not affect articular eminence and mandibular fossa morphology. It is concluded that the presence and extent of pneumatization of the TMJ temporal component does not affect its morphology. However, professionals should be aware of the high prevalence of pneumatization and take this into account when performing TMJ assessment.


Assuntos
Tomografia Computadorizada de Feixe Cônico , Articulação Temporomandibular , Feminino , Humanos , Masculino , Osso Temporal
2.
Animal ; 11(12): 2184-2192, 2017 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-28571587

RESUMO

The appropriate supply of nutrients in pregnant cows has been associated with the optimal development of foetal tissues, performance of their progeny and their meat quality. The aim of this study was to evaluate supplementation effects of grazing cows in different stages of gestation on skeletal muscle development and performance of the progeny. Thereby, 27 Nellore cows were divided into three groups (n=9 for each group) and their progeny as follows: UNS, unsupplemented during gestation; MID, supplemented from 30 to 180 days of gestation; LATE, supplemented from 181 to 281 days of gestation. The percentage composition of the supplement provided for the matrices was the following: ground corn (26.25%), wheat bran (26.25%) and soya bean meal (47.5%). The supplement was formulated to contain 30% CP. Supplemented matrices received 150 kg of supplement (1 and 1.5 kg/day for cows in the MID and LATE groups, respectively). After birth, a biopsy was performed to obtain samples of skeletal muscle tissue from calves to determine number and size of muscle fibres and for messenger RNA (mRNA) expression analysis. The percentage composition of the supplement provided for the progeny was the following: ground corn grain (30%), wheat bran (30%), soya bean meal (35%) and molasses (5%). The supplement was formulated to contain 25% CP and offered in an amount of 6 g/kg BW. Performance of the progeny was monitored throughout the suckling period. Means were submitted to ANOVA and regression, and UNS, MID and LATE periods of supplementation were compared. Differences were considered at P0.10). Similarly, no differences were observed between calves for nutrient intake (P>0.10). However, greater subcutaneous fat thickness (P=0.006) was observed in the calves of LATE group. The ribeye area (P=0.077) was greater in calves born from supplemented compared with UNS cows. The supplementation of pregnant cows did not affect the muscle fibre size of their progeny (P=0.208). On the other hand, calves born from dams supplemented at mid-gestation had greater muscle fibre number (P=0.093) compared with calves from UNS group. Greater mRNA expression of peroxysome proliferator-activated receptor α (P=0.073) and fibroblast growth factor 2 (P=0.003) was observed in the calves born from MID cows. Although strategic supplementation did not affect the BW of offspring, it did cause changes in carcass traits, number of myofibres, and mRNA expression of a muscle hypertrophy and lipid oxidation markers in skeletal muscle of the offspring.


Assuntos
Ração Animal/análise , Bovinos/fisiologia , Dieta/veterinária , Desenvolvimento Muscular/efeitos dos fármacos , Fenômenos Fisiológicos da Nutrição Pré-Natal/efeitos dos fármacos , Animais , Suplementos Nutricionais/análise , Ingestão de Energia , Feminino , Gravidez , Estações do Ano
3.
Anal Chim Acta ; 826: 1-11, 2014 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-24793847

RESUMO

In-tube solid-phase microextraction (in-tube SPME) coupled with high performance liquid chromatography (HPLC) or liquid chromatography coupled to mass spectrometry (LC-MS) successfully determines drugs or biomarkers in biological samples by direct sample injection or by simple sample treatment. This technique uses a capillary column as extraction device. Several capillaries (wall-coated open tubular, sorbent-packed, porous monolithic rods, or fiber-packed) with unique phases have been developed and evaluated, aiming to improve the efficiency and selectivity of the in-tube SPME-LC technique. This review describes new developments and applications occurred in recent years, and discusses future trends with emphasis on new extraction devices and current technology used for the synthesis of selective sorbents for bioanalysis, such as (i) polypyrrole, (ii) restricted-access materials, (iii) immunosorbents, (iv) molecular imprinting polymers, (v) monolithic polymers, and (vi) bi-functional materials.


Assuntos
Cromatografia Líquida/métodos , Microextração em Fase Sólida/instrumentação , Microextração em Fase Sólida/métodos , Animais , Biomarcadores , Preparações Farmacêuticas/análise
4.
J Chromatogr B Analyt Technol Biomed Life Sci ; 879(24): 2454-8, 2011 Aug 15.
Artigo em Inglês | MEDLINE | ID: mdl-21778122

RESUMO

A sensitive and automated method is described for determination of rifampicin in plasma samples for therapeutic drug monitoring by in-tube solid-phase microextraction coupled with liquid chromatography (in-tube SPME/LC). Important factors in the optimization of in-tube SPME are discussed, such as coating type, sample pH, sample draw/eject volume, number of draw/eject cycles, and draw/eject flow rate. Analyte pre-concentrated in the polyethylene glycol phase was directly transferred to the liquid chromatographic column by percolation of the mobile phase, without carryover. The method was linear over the 0.1-100 µg/mL range, with a linear coefficient value (r(2)) of 0.998. The inter-assay precision presented coefficient of variation ≤ 1.7%. The effectiveness and practicability of the proposed method are proven by analysis of plasma samples from ageing patients undergoing therapy with rifampicin.


Assuntos
Cromatografia Líquida/métodos , Rifampina/sangue , Rifampina/isolamento & purificação , Microextração em Fase Sólida/métodos , Automação , Humanos
6.
Anal Chim Acta ; 633(1): 57-64, 2009 Feb 02.
Artigo em Inglês | MEDLINE | ID: mdl-19110116

RESUMO

A new polymeric coating consisting of a dual-phase, polydimethylsiloxane (PDMS) and polypyrrole (PPY) was developed for the stir bar sorptive extraction (SBSE) of antidepressants (mirtazapine, citalopram, paroxetine, duloxetine, fluoxetine and sertraline) from plasma samples, followed by liquid chromatography analysis (SBSE/LC-UV). The extractions were based on both adsorption (PPY) and sorption (PDMS) mechanisms. SBSE variables, such as extraction time, temperature, pH of the matrix, and desorption time were optimized, in order to achieve suitable analytical sensitivity in a short time period. The PDMS/PPY coated stir bar showed high extraction efficiency (sensitivity and selectivity) toward the target analytes. The quantification limits (LOQ) of the SBSE/LC-UV method ranged from 20 ng mL(-1) to 50 ng mL(-1), and the linear range was from LOQ to 500 ng mL(-1), with a determination coefficient higher than 0.99. The inter-day precision of the SBSE/LC-UV method presented a variation coefficient lower than 15%. The efficiency of the SBSE/LC-UV method was proved by analysis of plasma samples from elderly depressed patients.


Assuntos
Antidepressivos/sangue , Dimetilpolisiloxanos/síntese química , Polímeros/síntese química , Pirróis/síntese química , Extração em Fase Sólida/métodos , Adsorção , Cromatografia Líquida/métodos , Concentração de Íons de Hidrogênio , Reprodutibilidade dos Testes , Temperatura , Fatores de Tempo
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa