1.
Biomaterials ; 29(9): 1147-58, 2008 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-18076983

RESUMO

We successfully fabricated transparent, robust hydrogels as corneal substitutes from concentrated recombinant human type I and type III collagen solutions crosslinked with 1-ethyl-3-(3-dimethyl aminopropyl) carbodiimide (EDC) and N-hydroxysuccinimide (NHS). White light transmission through these gels is comparable or superior to that of human corneas. Hydrogels from both type I and type III collagens supported in vitro epithelium and nerve over-growth. While both these biocompatible hydrogels have adequate tensile strength and elasticity for surgical manipulation, type III collagen hydrogels tended to be mechanically superior. Twelve-month post-implantation results of type I recombinant collagen-based corneal substitutes into mini-pigs showed retention of optical clarity, along with regeneration of corneal cells, nerves and tear film. For clinical use, implants based on fully characterized, recombinant human collagen eliminate the risk of pathogen transfer or xenogeneic immuno-responses posed by animal collagens.


Assuntos
Materiais Biocompatíveis , Colágeno/genética , Córnea , Engenharia Tecidual/métodos , Animais , Fenômenos Biomecânicos , Colágeno/isolamento & purificação , Colágeno Tipo I/genética , Colágeno Tipo I/isolamento & purificação , Colágeno Tipo III/genética , Colágeno Tipo III/isolamento & purificação , Córnea/fisiologia , Córnea/cirurgia , Transplante de Córnea , Reagentes de Ligações Cruzadas , Humanos , Hidrogéis , Teste de Materiais , Óptica e Fotônica , Proteínas Recombinantes/genética , Proteínas Recombinantes/isolamento & purificação , Regeneração , Suínos , Porco Miniatura , Termodinâmica
2.
Transl Vis Sci Technol ; 3(2): 6, 2014 04.
Artigo em Inglês | MEDLINE | ID: mdl-24749003

RESUMO

PURPOSE: Our aim was to determine the effect of a surgical technique on biomaterial implant performance, specifically graft retention. METHODS: Twelve mini pigs were implanted with cell-free, 1-ethyl-3-(3-dimethyl aminopropyl) carbodiimide (EDC)/N-hydroxysuccinimide (NHS) cross-linked recombinant human collagen type III (RHCIII) hydrogels as substitutes for donor corneal allografts using overlying sutures with or without human amniotic membrane (HAM) versus interrupted sutures with HAM. The effects of the retention method were compared as well as the effects of collagen concentration (13.7% to 15% RHCIII). RESULTS: All implanted corneas showed initial haze that cleared with time, resulting in corneas with optical clarity matching those of untreated controls. Biochemical analysis showed that by 12 months post operation, the initial RHCIII implants had been completely remodeled, as type I collagen, was the major collagenous protein detected, whereas no RHCIII could be detected. Histological analysis showed all implanted corneas exhibited regeneration of epithelial and stromal layers as well as nerves, along with touch sensitivity and tear production. Most neovascularization was seen in corneas stabilized by interrupted sutures. CONCLUSIONS: This showed that the surgical technique used does have a significant effect on the overall performance of corneal implants, overlying sutures caused less vascularization than interrupted sutures. TRANSLATIONAL RELEVANCE: Understanding the significance of the suturing technique can aid the selection of the most appropriate procedure when implanting artificial corneal substitutes. The same degree of regeneration, despite a higher collagen content indicates that future material development can progress toward stronger, more resistant implants.

3.
Biomaterials ; 35(8): 2420-7, 2014 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-24374070

RESUMO

We developed cell-free implants, comprising carbodiimide crosslinked recombinant human collagen (RHC), to enable corneal regeneration by endogenous cell recruitment, to address the worldwide shortage of donor corneas. Patients were grafted with RHC implants. Over four years, the regenerated neo-corneas were stably integrated without rejection, without the long immunosuppression regime needed by donor cornea patients. There was no recruitment of inflammatory dendritic cells into the implant area, whereas, even with immunosuppression, donor cornea recipients showed dendritic cell migration into the central cornea and a rejection episode was observed. Regeneration as evidenced by continued nerve and stromal cell repopulation occurred over the four years to approximate the micro-architecture of healthy corneas. Histopathology of a regenerated, clear cornea from a regrafted patient showed normal corneal architecture. Donor human cornea grafted eyes had abnormally tortuous nerves and stromal cell death was found. Implanted patients had a 4-year average corrected visual acuity of 20/54 and gained more than 5 Snellen lines of vision on an eye chart. The visual acuity can be improved with more robust materials for better shape retention. Nevertheless, these RHC implants can achieve stable regeneration and therefore, represent a potentially safe alternative to donor organ transplantation.


Assuntos
Materiais Biocompatíveis/uso terapêutico , Córnea/cirurgia , Proteínas Recombinantes/metabolismo , Regeneração/fisiologia , Alicerces Teciduais/química , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Colágeno/genética , Colágeno/metabolismo , Feminino , Humanos , Masculino , Microscopia Confocal , Pessoa de Meia-Idade , Próteses e Implantes , Proteínas Recombinantes/genética , Acuidade Visual , Adulto Jovem
4.
Methods Mol Biol ; 1014: 157-64, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-23690011

RESUMO

Human recombinant collagen can be cross-linked with a variety of chemical cross-linking agents. Cross-linking methods can be tuned to confer collagen-based scaffolds with specific physical properties, improved antigenicity and thermal stability without impeding the ability of the material to integrate into the surrounding tissue and to promote regeneration. Here, we describe a method to cross-link human recombinant collagen using a water soluble carbodiimide. Carbodiimides are referred to as zero-length cross-linking agents as they are not incorporated into the final cross-link and thus pose minimal risk with respect to cytotoxicity. The resulting collagen-based scaffold possesses properties comparable to that of the human cornea and is thus suitable for use as a corneal substitute.


Assuntos
Carbodi-Imidas/química , Colágeno/química , Engenharia Tecidual , Humanos , Organoides/transplante , Próteses e Implantes , Proteínas Recombinantes/química , Alicerces Teciduais
5.
Acta Biomater ; 9(8): 7796-805, 2013 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-23619290

RESUMO

We have previously shown that recombinant human collagen can be crosslinked with N-(3-dimethylaminopropyl)-N'-ethylcarbodiimide (EDC) to fabricate transparent hydrogels possessing the shape and dimensions of the human cornea. These corneal implants have been tested in a Phase I human clinical study. Although these hydrogels successfully promoted corneal tissue and nerve regeneration, the gelling kinetics were difficult to control during the manufacture of the implants. An alternative carbodiimide capable of producing hydrogels of similar characteristics as EDC in terms of strength and biocompatibility, but with a longer gelation time would be a desirable alternative. Here, we compared the crosslinking kinetics and properties of hydrogels crosslinked with a sterically bulky carbodiimide, N-Cyclohexyl-N'-(2-morpholinoethyl) carbodiimide metho-p-toluenesulfonate (CMC), with that of EDC. CMC crosslinking was possible at ambient temperature whereas the EDC reaction was too rapid to control and had to be carried out at low temperatures. The highest tensile strength obtained using optimized formulations were equivalent, although CMC crosslinked hydrogels were found to be stiffer. The collagenase resistance of CMC crosslinked hydrogels was superior to that of EDC crosslinked hydrogels while biocompatibility was similar. We are also able to substitute porcine collagen with recombinant human collagen and show that the in vivo performance of both resulting hydrogels as full-thickness corneal implants is comparable in a mouse model of an orthotopic corneal graft. In conclusion, CMC is a viable alternative to EDC as a crosslinker for collagen-based biomaterials for use as corneal implants, and potentially for use in other tissue engineering applications.


Assuntos
Carbodi-Imidas/química , Colágeno Tipo I/química , Córnea/cirurgia , Transplante de Córnea/instrumentação , Reagentes de Ligações Cruzadas/química , Hidrogéis/química , Próteses e Implantes , Animais , Córnea/citologia , Módulo de Elasticidade , Desenho de Equipamento , Análise de Falha de Equipamento , Dureza , Teste de Materiais , Camundongos , Camundongos Endogâmicos BALB C , Suínos , Resistência à Tração , Resultado do Tratamento
6.
J Funct Biomater ; 4(3): 162-77, 2013 Aug 28.
Artigo em Inglês | MEDLINE | ID: mdl-24956085

RESUMO

A bi-functional epoxy-based cross-linker, 1,4-Butanediol diglycidyl ether (BDDGE), was investigated in the fabrication of collagen based corneal substitutes. Two synthetic strategies were explored in the preparation of the cross-linked collagen scaffolds. The lysine residues of Type 1 porcine collagen were directly cross-linked using l,4-Butanediol diglycidyl ether (BDDGE) under basic conditions at pH 11. Alternatively, under conventional methodology, using both BDDGE and 1-Ethyl-3-(3-dimethyl aminopropyl) carbodiimide (EDC)/N-hydroxysuccinimide (NHS) as cross-linkers, hydrogels were fabricated under acidic conditions. In this latter strategy, Cu(BF4)2·XH2O was used to catalyze the formation of secondary amine bonds. To date, we have demonstrated that both methods of chemical cross-linking improved the elasticity and tensile strength of the collagen implants. Differential scanning calorimetry and biocompatibility studies indicate comparable, and in some cases, enhanced properties compared to that of the EDC/NHS controls. In vitro studies showed that human corneal epithelial cells and neuronal progenitor cell lines proliferated on these hydrogels. In addition, improvement of cell proliferation on the surfaces of the materials was observed when neurite promoting laminin epitope, IKVAV, and adhesion peptide, YIGSR, were incorporated. However, the elasticity decreased with peptide incorporation and will require further optimization. Nevertheless, we have shown that epoxy cross-linkers should be further explored in the fabrication of collagen-based hydrogels, as alternatives to or in conjunction with carbodiimide cross-linkers.

7.
Invest Ophthalmol Vis Sci ; 52(2): 651-7, 2011 Feb 03.
Artigo em Inglês | MEDLINE | ID: mdl-20847116

RESUMO

PURPOSE: To evaluate the performance of structurally reinforced, stabilized recombinant human collagen-phosphorylcholine (RHCIII-MPC) hydrogels as corneal substitutes in a rabbit model of severe corneal damage. METHODS: One eye each of 12 rabbits received a deep corneal alkali wound. Four corneas were implanted with RHCIII-MPC hydrogels. The other eight control corneas were implanted with either allografts or a simple cross-linked RHCIII hydrogel. In all cases, 6.25 mm diameter, 350 µm thick buttons were implanted by anterior lamellar keratoplasty to replace damaged corneal tissue. Implants were followed for nine months by clinical examination and in vivo confocal microscopy, after which implanted corneas were removed and processed for histopathological and ultrastructural examination. RESULTS: Alkali exposure induced extensive central corneal scarring, ocular surface irregularity, and neovascularization in one case. All implants showed complete epithelial coverage by four weeks postoperative, but with accompanying suture-induced vascularization in 6 out of 12 cases. A stable, stratified epithelium with hemidesmosomal adhesion complexes regenerated over all implants, and subbasal nerve regeneration was observed in allograft and RHCIII-MPC implants. Initially acellular biosynthetic implants were populated with host-derived keratocytes as stromal haze subsided and stromal collagen was remodeled. Notably, RHCIII-MPC implants exhibited resistance to vascular ingrowth while supporting endogenous cell and nerve repopulation. CONCLUSIONS: Biosynthetic implants based on RHC promoted cell and nerve repopulation in alkali burned rabbit eyes. In RHCIII-MPC implants, evidence of an enhanced resistance to neovascularization was additionally noted.


Assuntos
Órgãos Artificiais , Queimaduras Químicas/cirurgia , Córnea , Opacidade da Córnea/cirurgia , Transplante de Córnea , Queimaduras Oculares/induzido quimicamente , Animais , Queimaduras Químicas/patologia , Colágeno Tipo III/química , Neovascularização da Córnea/induzido quimicamente , Neovascularização da Córnea/metabolismo , Neovascularização da Córnea/cirurgia , Opacidade da Córnea/induzido quimicamente , Opacidade da Córnea/metabolismo , Epitélio Corneano/fisiologia , Hidrogéis , Metacrilatos/química , Microscopia Confocal , Microscopia Eletrônica de Transmissão , Modelos Animais , Fosforilcolina/análogos & derivados , Fosforilcolina/química , Coelhos , Regeneração/fisiologia , Hidróxido de Sódio , Transplante Homólogo
8.
Sci Transl Med ; 2(46): 46ra61, 2010 Aug 25.
Artigo em Inglês | MEDLINE | ID: mdl-20739681

RESUMO

Corneas from human donors are used to replace damaged tissue and treat corneal blindness, but there is a severe worldwide shortage of donor corneas. We conducted a phase 1 clinical study in which biosynthetic mimics of corneal extracellular matrix were implanted to replace the pathologic anterior cornea of 10 patients who had significant vision loss, with the aim of facilitating endogenous tissue regeneration without the use of human donor tissue. The biosynthetic implants remained stably integrated and avascular for 24 months after surgery, without the need for long-term use of the steroid immunosuppression that is required for traditional allotransplantation. Corneal reepithelialization occurred in all patients, although a delay in epithelial closure as a result of the overlying retaining sutures led to early, localized implant thinning and fibrosis in some patients. The tear film was restored, and stromal cells were recruited into the implant in all patients. Nerve regeneration was also observed and touch sensitivity was restored, both to an equal or to a greater degree than is seen with human donor tissue. Vision at 24 months improved from preoperative values in six patients. With further optimization, biosynthetic corneal implants could offer a safe and effective alternative to the implantation of human tissue to help address the current donor cornea shortage.


Assuntos
Córnea/fisiopatologia , Ceratocone/cirurgia , Regeneração , Doadores de Tecidos , Adolescente , Adulto , Idoso , Astigmatismo , Matriz Extracelular , Seguimentos , Humanos , Ceratocone/fisiopatologia , Pessoa de Meia-Idade , Acuidade Visual
9.
Biomaterials ; 30(29): 5403-8, 2009 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-19576630

RESUMO

Saturated neoglycopolymers, prepared via tandem ROMP-hydrogenation (ROMP=ring-opening metathesis polymerization) of carbohydrate-functionalized norbornenes, are investigated as novel collagen crosslinking agents in corneal tissue engineering. The neoglycopolymers were incorporated into recombinant human collagen type III (RHC III) as collagen crosslinking agents and glycosaminoglycan (GAG) mimics. The purely synthetic nature of these composites is designed to reduce susceptibility to immunological and allergic reactions, and to circumvent the transmission of animal infectious diseases. The collagen-neoglycopolymer biomaterials exhibit higher stability to collagenase-induced biodegradation than the control materials, composites of RHC III crosslinked using EDC/NHS (EDC=1-ethyl-3-(3-dimethyl aminopropyl) carbodiimide; NHS=N-hydroxysuccinimide). Even at this proof of concept stage, the thermal stability, enzymatic resistance, and permeability of the neoglycopolymer hydrogels are comparable or superior to those of these fully optimized control materials, which have successfully been tested clinically. Tensile strength is adequate for transplantation, but lower than that of the optimized control materials.


Assuntos
Materiais Biocompatíveis/química , Materiais Biomiméticos/química , Colágeno/química , Córnea/crescimento & desenvolvimento , Polímeros/química , Líquidos Corporais/química , Reagentes de Ligações Cruzadas/química , Módulo de Elasticidade , Humanos , Teste de Materiais , Proteínas Recombinantes/química
10.
Invest Ophthalmol Vis Sci ; 49(9): 3895-902, 2008 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-18408185

RESUMO

PURPOSE: To compare reinnervation in recombinant human collagen-based corneal substitutes with allografts during a 1-year postimplantation follow-up period in pigs. A retrospective comparison to innervation in porcine collagen-based biosynthetic grafts was also performed. METHODS: Pigs received a corneal allograft or a substitute made of either recombinant human type-I or -III collagen. In vivo confocal microscopic examination of the central cornea of surgical and untouched control eyes before surgery and at 2, 6, and 12 months after surgery was performed to quantify the number, density, and diameter of nerves at various corneal depths. RESULTS: By 12 months after surgery, the number and density of regenerated nerves in the anterior and deep anterior corneal stroma recovered to preoperative and control levels in both types of substitute grafts and in the allografts. In the subepithelial and subbasal regions, however, significantly fewer nerves were detected relative to those in control subjects at 12 months, regardless of graft type (P < 0.05), similar to the behavior of porcine collagen-based biosynthetic grafts. An absence of thick stromal nerve trunks (diameter, >10 mum) in all grafts, irrespective of material type, indicated that nerve regeneration in grafts was accompanied by persistent morphologic changes. CONCLUSIONS: Nerve regeneration in recombinant human collagen-based biosynthetic corneal grafts proceeded similarly to that in allograft tissue, demonstrating the suitability of recombinant human collagen constructs as nerve-friendly corneal substitutes. Furthermore, only minor differences were noted between type-I and -III collagen grafts, indicating an insensitivity of nerve regeneration to initial collagen type.


Assuntos
Órgãos Artificiais/normas , Colágeno/genética , Córnea/citologia , Córnea/fisiologia , Engenharia Tecidual/métodos , Animais , Transplante de Córnea/métodos , Humanos , Microscopia Confocal , Regeneração Nervosa/fisiologia , Nervo Óptico/fisiologia , Proteínas Recombinantes/metabolismo , Suínos , Transplante Heterólogo , Transplante Homólogo
11.
Invest Ophthalmol Vis Sci ; 49(9): 3887-94, 2008 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-18515574

RESUMO

PURPOSE: To compare the efficacies of recombinant human collagens types I and III as corneal substitutes for implantation. METHODS: Recombinant human collagen (13.7%) type I or III was thoroughly mixed with 1-ethyl-3-(3-dimethylaminopropyl)carbodiimide and N-hydroxysuccinimide. The final homogenous solution was either molded into sheets for in vitro studies or into implants with the appropriate corneal dimensions for transplantation into minipigs. Animals with implants were observed for up to 12 months after surgery. Clinical examinations of the cornea included detailed slit lamp biomicroscopy, in vivo confocal microscopy, and fundus examination. Histopathologic examinations were also performed on corneas harvested after 12 months. RESULTS: Both cross-linked recombinant collagens had refractive indices of 1.35, with optical clarity similar to that in human corneas. Their chemical and mechanical properties were similar, although RHC-III implants showed superior optical clarity. Implants into pig corneas over 12 months show comparably stable integration, with regeneration of corneal cells, tear film, and nerves. Optical clarity was also maintained in both implants, as evidenced by fundus examination. CONCLUSIONS: Both RHC-I and -III implants can be safely and stably integrated into host corneas. The simple cross-linking methodology and recombinant source of materials makes them potentially safe and effective future corneal matrix substitutes.


Assuntos
Órgãos Artificiais/estatística & dados numéricos , Materiais Biocompatíveis/química , Colágeno Tipo III/genética , Colágeno Tipo I/genética , Colágeno/fisiologia , Córnea/fisiologia , Transplante de Córnea/métodos , Fenômenos Biomecânicos , Humanos , Proteínas Recombinantes , Refratometria , Resistência à Tração , Engenharia Tecidual/métodos
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa