Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 51
Filtrar
1.
Ophthalmic Physiol Opt ; 43(4): 860-873, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-37083081

RESUMO

PURPOSE: To evaluate the feasibility and repeatability of IOLMaster 700 biometry measurements in an adult population. Furthermore, to assess the value of the Quality Indicators (QIs) provided by the device. METHOD: As part of the large population-based Leipzig Research Centre for Civilization Diseases (LIFE) Adult-Study, randomly selected participants from Leipzig, Germany were evaluated with the ZEISS IOLMaster 700. Age range was 26-85 years, with 53% of participants above 70 years of age. Axial length (AL), central corneal thickness (CCT), anterior chamber depth (ACD), lens thickness (LT) and keratometry (K) were assessed in 1767 right eyes. Measurements were repeated twice and in a subset of 1331 eyes, three times. Measurement feasibility was evaluated for three levels; successful, with warnings and failed, using the inbuilt QIs. Repeatability was assessed as within-subject standard deviation (SD) and repeatability limits were calculated. RESULTS: First measurement success rate for phakic eyes was over 99% for AL, CCT, ACD, over 98% for LT and over 97% for K. K had 16% eyes with warnings and the recommendation to repeat the measurement. Excluding the measurements with warnings resulted in a reduction of mean SD for AL from 48 to 4 µm and for mean K from 0.08 to 0.04 D. Repeatability for phakic eyes was 8 µm for AL, CCT, ACD and LT and 2.3 µm for CCT; 0.07 D and 0.12 D for mean K and delta K, respectively, for phakic cases without warnings (two measurements). CONCLUSIONS: In our population-based sample, the IOLMaster 700 collected data for AL, CCT, ACD, LT and K from the vast majority of eyes. Considering the built-in QIs improved the measurement variability substantially. Repeatability measurements indicate that clinically meaningful changes can be detected reliably with this instrument.


Assuntos
Comprimento Axial do Olho , Tomografia de Coerência Óptica , Adulto , Humanos , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais , Estudos de Viabilidade , Comprimento Axial do Olho/anatomia & histologia , Tomografia de Coerência Óptica/métodos , Reprodutibilidade dos Testes , Estudos Prospectivos , Córnea/diagnóstico por imagem , Córnea/anatomia & histologia , Biometria/métodos , Câmara Anterior/diagnóstico por imagem
2.
Mol Ther ; 29(2): 804-821, 2021 02 03.
Artigo em Inglês | MEDLINE | ID: mdl-33264643

RESUMO

Cell therapy approaches hold great potential for treating retinopathies, which are currently incurable. This study addresses the problem of inadequate migration and integration of transplanted cells into the host retina. To this end, we have identified the chemokines that were most upregulated during retinal degeneration and that could chemoattract mesenchymal stem cells (MSCs). The results were observed using a pharmacological model of ganglion/amacrine cell degeneration and a genetic model of retinitis pigmentosa, from both mice and human retinae. Remarkably, MSCs overexpressing Ccr5 and Cxcr6, which are receptors bound by a subset of the identified chemokines, displayed improved migration after transplantation in the degenerating retina. They also led to enhanced rescue of cell death and to preservation of electrophysiological function. Overall, we show that chemokines released from the degenerating retinae can drive migration of transplanted stem cells, and that overexpression of chemokine receptors can improve cell therapy-based regenerative approaches.


Assuntos
Células-Tronco Mesenquimais/metabolismo , Receptores CCR5/genética , Receptores CXCR6/genética , Degeneração Retiniana/etiologia , Degeneração Retiniana/metabolismo , Animais , Biomarcadores , Movimento Celular , Suscetibilidade a Doenças , Expressão Gênica , Humanos , Camundongos , Receptores CCR5/metabolismo , Receptores CXCR6/metabolismo , Degeneração Retiniana/patologia
3.
Int J Mol Sci ; 23(21)2022 Oct 31.
Artigo em Inglês | MEDLINE | ID: mdl-36362082

RESUMO

Soemmerring's rings consist of a ring of lens epithelial derived cells that grow along the periphery of an aphakic lens capsule, or around an intraocular lens. These rings when visualized frontally, appear opaque, however, in some cases the cells that compose these rings are organized in the same fashion as those in normal transparent adult lenses. Thus, our purpose was to test whether any part of the adult Soemmerring's ring could be transparent and how this related to morphological factors. To study this, 16 Soemmerring's rings were extracted from donor eye globes. After imaging, they were thickly sectioned sagittally in order to analyze the degrees of transparency of different areas. All samples were also histologically analyzed using alpha smooth muscle actin, Vimentin, wheat germ agglutinin and DAPI. Our results showed that many samples had some transparent areas, mostly towards the center of their cross-section. Of the factors that we analyzed, only lens fiber organization at the bow region and an increased area of mature lens fiber cells had a significant relation to the degree of transparency at the center. Thus, we can conclude that as Soemmerring's rings mature, they can develop organized and transparent areas of lens cells.


Assuntos
Cápsula do Cristalino , Cristalino , Lentes Intraoculares , Humanos , Epitélio
4.
Ophthalmic Physiol Opt ; 41(3): 512-522, 2021 05.
Artigo em Inglês | MEDLINE | ID: mdl-33772832

RESUMO

PURPOSE: To evaluate the feasibility and repeatability of Lenstar LS 900 biometry measurements in a paediatric population. METHODS: Children were examined as part of the LIFE Child Study (Leipzig Research Centre for Civilization Diseases), a population-based study in Leipzig, Germany. Altogether, 1917 children, aged from 3.5 to 17.5 years, were assessed with the Haag Streit Lenstar LS 900. Three consecutive measurements of the right eye were analysed for axial length, central corneal thickness, anterior chamber depth, aqueous depth, lens thickness and flat and steep corneal radii. The number of successful measurements and repeatability were evaluated for each parameter and three age bands (3.5 to 6.5 years, 6.5 to 10.5 years and 10.5 to 17.5 years). RESULTS: Best measurement feasibility was found for axial length and central corneal thickness (91% to 100%), followed by flat and steep corneal radii (86% to 100%), anterior chamber and aqueous depth (76% to 92%) and lens thickness (50% to 81%), with higher numbers for older children. Repeatability values (in mm) were: axial length 0.025 to 0.035; central corneal thickness 0.003 to 0.027; aqueous depth 0.024 to 0.058; anterior chamber 0.024 to 0.054; lens thickness 0.034 to 0.067. An overall trend showed better repeatability for older children, especially for central corneal thickness, aqueous depth and lens thickness. CONCLUSIONS: For ocular biometry in the paediatric population, axial length, central corneal thickness, flat and steep corneal radii can be measured very reliably even in children from 4 years old onward using the Lenstar LS 900. Lens thickness can be quantified in a limited number of younger children. Repeatability was high for all variables investigated. Repeatability improved with age, reaching adult values in the adolescent age band. Established repeatability limits can be applied in future studies as a quality parameter.


Assuntos
Comprimento Axial do Olho/diagnóstico por imagem , Biometria/instrumentação , Córnea/diagnóstico por imagem , Erros de Refração/diagnóstico , Adolescente , Adulto , Criança , Pré-Escolar , Topografia da Córnea , Desenho de Equipamento , Estudos de Viabilidade , Feminino , Humanos , Interferometria/métodos , Masculino , Pessoa de Meia-Idade , Erros de Refração/fisiopatologia , Adulto Jovem
5.
Ophthalmic Physiol Opt ; 41(3): 496-511, 2021 05.
Artigo em Inglês | MEDLINE | ID: mdl-33960004

RESUMO

PURPOSE: To evaluate ocular biometry in a large paediatric population as a function of age and sex in children of European descent. METHODS: Children were examined as part of the LIFE Child Study (Leipzig Research Centre for Civilization Disease), a population-based study in Leipzig, Germany. Altogether, 1907 children, aged from 4 to 17 years, were examined with the Lenstar LS 900. Data from the right eye was analysed for axial length, central corneal thickness, flat and steep corneal radii, aqueous depth, lens thickness and vitreous depth. Wavefront-based autorefraction was employed for analysis. RESULTS: Axial length increased in girls from 21.6 mm (4 years) up to 23.4 mm (17 years); this increase (0.174 mm per year) was statistically significant up to age 14 (23.3 mm). Axial length increased in boys from 22.2 mm (4 years) up to 23.9 mm (17 years); this increase (0.178 mm per year) was statistically significant up to age 10 (23.3 mm). No change was observed for central corneal thickness (average: girls 550 µm; boys 554 µm). Corneal curvature in girls was somewhat flatter at age 4 (7.70 mm) compared to age 10 (7.78 mm), whereas it was constant in boys (7.89 mm). Aqueous depth at age 4 was 2.73 mm for girls and 2.86 mm for boys, with the same rate of increase per year (girls: 0.046 mm; boys: 0.047 mm) from age 4 to 10. At age 17, aqueous depth was 3.06 mm in girls and 3.20 mm in boys. Lens thickness was reduced from age 4 (3.75 mm) to age 10 (3.47 mm) in girls and from age 4 (3.73 mm) to age 10 (3.44 mm) in boys, with the same rate of decrease per year of 0.046 and 0.047 mm, respectively. At age 17, lens thickness was 3.52 mm in girls and 3.50 mm in boys. Vitreous depth at age 4 was 14.51 mm for girls and 15.08 mm for boys; with 0.156 mm (girls) or 0.140 mm (boys) increase per year until age 14 (girls: 16.08 mm; boys: 16.48 mm). At age 17, vitreous depth was 16.29 mm in girls and 16.62 mm in boys. CONCLUSIONS: Eye growth (axial length) in girls showed a lag of about four years compared to boys. Aqueous depth increase matches the lens thickness decrease from ages 4 to 10 years in girls and boys. Lens thickness minimum is reached at 11 years in girls and at 12 years in boys. All dimensions of the optical ocular components are closely correlated with axial length. These data may serve as normative values for the assessment of eye growth in central European children and will provide a basis for monitoring refractive error development.


Assuntos
Câmara Anterior/diagnóstico por imagem , Comprimento Axial do Olho/fisiopatologia , Biometria/métodos , Refração Ocular/fisiologia , Erros de Refração/diagnóstico , Adolescente , Fatores Etários , Comprimento Axial do Olho/diagnóstico por imagem , Criança , Pré-Escolar , Estudos Transversais , Feminino , Seguimentos , Alemanha/epidemiologia , Humanos , Incidência , Lactente , Masculino , Erros de Refração/epidemiologia , Erros de Refração/fisiopatologia , Fatores Sexuais
6.
Exp Eye Res ; 188: 107807, 2019 11.
Artigo em Inglês | MEDLINE | ID: mdl-31539543

RESUMO

In order to study the mechanisms involved in the development of posterior capsule opacification (PCO) we compared in vivo developed PCO with PCO formed in tissue culture with focus on the periphery of the lens capsule to evaluate lens regeneration potential. We studied three human tissue groups: Cultured lens capsules after mock cataract surgery (n = 6, 30 days), lens capsules from donors that had previously undergone cataract surgery (IOL capsules) (n = 12) and intact lenses (n = 6). All samples were stained with Vimentin, alpha Smooth Muscle Actin, Picro Sirius Red (for collagen) and Paired box protein (Pax6). We found that cultured capsules and less developed IOL capsules consisted mainly of monolayers of mesenchymal cells, while more developed IOL capsules, contained lens epithelial cells (LECs), globular cells and lens fiber cells. Many IOL capsule samples expressed collagen I and III in areas where cells were in contact with the IOL. Pax6 had a similar dispersed distribution in less developed IOL capsules and cultured capsules, while more developed IOL capsules and intact lenses, concentrated Pax6 in LECs at the equatorial lens bow. The similarities between cultured capsules and less developed IOL capsules indicate that our in vitro developed PCO is comparable to early in vivo developed PCO. The similar morphology of more developed IOL capsules and intact lenses seems to indicate an attempt at lens regeneration.


Assuntos
Opacificação da Cápsula/patologia , Cápsula Posterior do Cristalino/patologia , Actinas/metabolismo , Adulto , Idoso , Idoso de 80 Anos ou mais , Biomarcadores/metabolismo , Opacificação da Cápsula/metabolismo , Extração de Catarata , Feminino , Humanos , Técnicas Imunoenzimáticas , Implante de Lente Intraocular , Masculino , Pessoa de Meia-Idade , Técnicas de Cultura de Órgãos , Cápsula Posterior do Cristalino/metabolismo , Doadores de Tecidos , Vimentina/metabolismo
7.
Ophthalmic Res ; 62(3): 157-165, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-30921809

RESUMO

PURPOSE: To evaluate the relationship between the presence of cortical cataract and accommodation effort, using refractive error as a proxy. METHODS: Patients between 50 and 90 years, scheduled for cataract surgery, were selected with the help of a photographic database. Nuclear and cortical cataract were graded and patients grouped having no cataract, pure cortical, mixed or pure nuclear cataract. Refraction data at the time of the photograph was converted to estimated spherical equivalent refractive error each patient would have had at the age of 45 years. RESULTS: From the initial 239 eyes from 239 patients, cases with myopia below -6.5 dpt and hyperopia above 6.5 dpt were excluded, resulting in 199 cases for final analysis. Eyes with no cataract showed the lowest median refractive error (-3.65 dpt), followed by the pure nuclear group (-2.69 dpt). The median refractive error for pure cortical (-0.23 dpt) and mixed cataracts (-0.87 dpt) were close to emmetropia. Cortical cataracts were found in 37% of myopes, 82% of emmetropes, and 85% of hyperopes. CONCLUSION: Emmetropes and hyperopes tend to develop more cortical cataract than myopes. These cortical cataracts might be caused by shear stress inside the crystalline lens due to accommodation efforts at the time of onset of presbyopia.


Assuntos
Catarata/fisiopatologia , Refração Ocular/fisiologia , Erros de Refração/fisiopatologia , Idoso , Idoso de 80 Anos ou mais , Catarata/complicações , Emetropia/fisiologia , Feminino , Humanos , Hiperopia/fisiopatologia , Masculino , Pessoa de Meia-Idade , Miopia/fisiopatologia , Erros de Refração/etiologia
8.
Postgrad Med J ; 95(1124): 323-327, 2019 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-31177191

RESUMO

There is a major problem with medical recruitment and retention in the UK. The 2018 General Medical Council (GMC) report 'The state of medical education and practice in the UK' has indicated that a high proportion of doctors are thinking of either giving up medical practice or reducing their hours in the next 3 years. If this trend continues the shortage of doctors in the UK will increase despite a modest increase in the supply of doctors.This paper investigates the evidence that increasing the academic component of medical posts may help retain doctors in practice by providing experience and support in an area of medical practice, which appears to fulfil a significant number of doctors' aspirations. The paper shows that this aspect of medical practice is poorly represented in medical workforce strategic thinking and should be considered as an integral aspect of policy and practice in medical workforce delivery.


Assuntos
Docentes de Medicina , Seleção de Pessoal , Médicos/provisão & distribuição , Aposentadoria , Escolha da Profissão , Educação de Pós-Graduação em Medicina , Humanos , Medicina Estatal , Reino Unido
9.
Exp Eye Res ; 168: 19-27, 2018 03.
Artigo em Inglês | MEDLINE | ID: mdl-29288023

RESUMO

Experimental protocols have been developed to measure the spatial variation of the mechanical strains induced in the lens capsule during ex vivo lens stretching. The paper describes the application of these protocols to porcine lenses. The deformations and mechanical strains developed in the anterior capsule during each experiment were determined using full field digital image correlation techniques, by means of a speckle pattern applied to the lens surface. Several speckling techniques and illumination methods were assessed before a suitable combination was found. Additional data on the cross section shape of the anterior lens surface were obtained by Scheimpflug photography, to provide a means of correcting for lens curvature effects in the determination of the strains developed in the plane of the capsule. The capsule strains in porcine lenses exhibit non-linear behaviour, and hysteresis during loading and unloading. Peripheral regions experience higher magnitude strains than regions near the lens pole. The paper demonstrates the successful application of a procedure to make direct measurements of capsule strains simultaneously with ex vivo radial lens stretching. This experimental technique is applicable to future investigations on the mechanical characteristics of human lenses.


Assuntos
Acomodação Ocular/fisiologia , Cápsula Anterior do Cristalino/fisiologia , Cápsula do Cristalino/fisiologia , Animais , Comprimento Axial do Olho/fisiologia , Modelos Animais , Suínos
10.
Ophthalmic Res ; 57(4): 247-251, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28288454

RESUMO

PURPOSE: To evaluate a new nuclear cataract grading system which is intended as a surgical guidance system to predict lens hardness before cataract surgery. METHODS: The new BCN 10 grading system consists of frontal and cross-sectional slit-lamp images of human eye lenses, ranging from a completely transparent lens nucleus to a totally black nuclear cataract. Validation was done with 9 observers for 110 cases. Two modalities were applied, and observers were asked to use only whole digits and then half digits for grading. RESULTS: Repeatability with regard to test-retest differences showed a mean limit of agreement of 1.70 for whole digits and 1.32 for half digits. The absolute test-retest difference was close to zero for low as well high degrees of cataracts. Reliability for the entire group of 9 observers yielded an intraclass correlation coefficient which was within the same confidence interval, i.e., 0.991-0.995, for whole digits and half digits. CONCLUSIONS: BCN 10 grading repeatability was not affected by the severity of the cataract. It showed very good repeatability. Repeatability was significantly higher when the observers used half digits compared to whole digits. Reliability was found to be very good as well, independently of the use of whole or half digits.


Assuntos
Envelhecimento , Catarata/congênito , Núcleo do Cristalino/diagnóstico por imagem , Idoso , Catarata/classificação , Catarata/diagnóstico , Estudos Transversais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Índice de Gravidade de Doença
11.
Exp Eye Res ; 145: 100-109, 2016 04.
Artigo em Inglês | MEDLINE | ID: mdl-26611157

RESUMO

A combination of Raman spectroscopy, imaging, hierarchical cluster analysis (HCA) and peak ratio analysis was used to analyze protein profiles in the superficial cortex (SC), deep cortex (DC) and nucleus of old human lenses with cortical, nuclear and mixed cataracts. No consistent differences were observed in protein spectra and after cluster analysis between the three locations irrespective of the presence or absence of cortical opacities and/or coloration. A sharp increase (∼15%-∼33%) in protein content from SC to DC, normal for human lenses, was found in 7 lenses. In 4 lenses, characterized by the absence of cortical opacities, the SC has a protein content of ∼35%. A significant increase in the disulfide-to-protein ratio is found only in the SC of the 7 cortical cataracts. No changes were found in sulfhydryl-to-protein ratio. The relative contents of α-helices and ß-sheets increase from SC to nucleus. ß-Sheets are more common in the SC of lenses with cortical cataract. The absence of significant and consistent changes in protein profiles between nucleus and cortex even in cases of severe coloration is not favoring the prevailing concept that ubiquitous protein oxidation is a key factor for age related nuclear (ARN) cataracts. The observations favor the idea that multilamellar bodies or protein aggregates at very low volume densities are responsible for the rise in Mie light scatter as a main cause of ARN cataracts leaving the short-range-order of the fiber cytoplasm largely intact. The absence of significant changes in the protein spectra of the deep cortical opacities, milky white as a result of the presence of vesicle-like features, indicate they are packed with relatively undisturbed crystallins.


Assuntos
Catarata/metabolismo , Cristalinas/metabolismo , Córtex do Cristalino/metabolismo , Núcleo do Cristalino/metabolismo , Doadores de Tecidos , Idoso , Idoso de 80 Anos ou mais , Catarata/diagnóstico , Feminino , Humanos , Masculino , Análise Espectral Raman
12.
Ophthalmic Res ; 56(4): 202-206, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27160090

RESUMO

PURPOSE: To evaluate the corneal button of primary penetrating keratoplasty of patients diagnosed with congenital aniridia. The study took place at the Instituto Universitario Barraquer and the Centro de Oftalmología Barraquer. METHODS: A retrospective analysis of cases diagnosed with congenital aniridia was carried out. We analyzed 13 corneal buttons of 11 eyes with congenital aniridia. We only included those patients who underwent penetrating keratoplasty for the first time. The corneal buttons were analyzed for histological characteristics of the presence of vascularization, the presence or not of Bowman's layer, the thickness of the stroma and Descemet's membrane, and endothelium layer alterations. RESULTS: We found alterations in the epithelium and stroma in all patients, although this loss of architecture was not seen in Descemet's membrane and the endothelial population. CONCLUSION: Patients with advanced congenital aniridic keratopathy may be good candidates for deep or superficial anterior lamellar keratoplasty for the preservation of normal endothelium and Descemet's membrane, along with limbal stem cell transplantation, to address epithelial and stromal pathology.


Assuntos
Aniridia/patologia , Córnea/patologia , Ceratoplastia Penetrante , Adulto , Aniridia/cirurgia , Contagem de Células , Córnea/cirurgia , Lâmina Limitante Posterior/patologia , Endotélio Corneano/patologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Acuidade Visual , Adulto Jovem
13.
Exp Eye Res ; 119: 44-53, 2014 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-24333259

RESUMO

We have compared the protein profiles in plaques and tangles in the hippocampus of post-mortem Alzheimer brains and in opaque and clear regions in the deep cortex of eye lenses of the same donors. From the 7 Alzheimer donors studied, 1 had pronounced bilateral cortical lens opacities, 1 moderate and 5 only minor or no cortical opacities. We focused on beta-sheet levels, a hallmarking property of amyloid-beta, the major protein of plaques and tau protein, the major protein of tangles in Alzheimer brains. Confocal Raman microspectroscopy and imaging was used in combination with hierarchical cluster analysis. Plaques and tangles show high levels of beta-sheets with a beta-sheet to protein ratio of 1.67. This ratio is 1.12 in unaffected brain tissue surrounding the plaques and tangles. In the lenses this ratio is 1.17 independently of the presence or absence of opacities. This major difference in beta-sheet conformation between hippocampus and lens is supported by Congo red and immunostaining of amyloid-beta and tau which were positive for plaques and tangles in the hippocampus but fully negative for the lens irrespective of the presence or absence of opacities. In line with a previous study (Michael et al., 2013) we conclude that cortical lens opacities are not typical for Alzheimer patients and are not hallmarked by accumulation of amyloid-beta, and can thus not be considered as predictors or indicators of Alzheimer disease as claimed by Goldstein et al. (2003).


Assuntos
Doença de Alzheimer/metabolismo , Peptídeos beta-Amiloides/análise , Catarata/metabolismo , Cristalino/química , Placa Amiloide/química , Análise Espectral Raman/métodos , Idoso , Idoso de 80 Anos ou mais , Doença de Alzheimer/complicações , Doença de Alzheimer/patologia , Catarata/complicações , Catarata/patologia , Feminino , Hipocampo/química , Hipocampo/patologia , Humanos , Imuno-Histoquímica , Masculino , Pessoa de Meia-Idade
14.
Graefes Arch Clin Exp Ophthalmol ; 252(1): 83-90, 2014 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-24390466

RESUMO

PURPOSE: To describe the outcome of patients with Boston type 1 keratoprosthesis, with regard to anatomical and visual success. METHODS: Retrospective case series of patients who underwent Boston type I keratoprosthesis surgery at the Centro de Oftalmología Barraquer in Barcelona and at the University Eye Clinic in Salzburg between May 2006 and December 2011. Sixty-seven eyes were included. Anatomical success, visual acuity, and complication rate were evaluated and correlated with the initial diagnosis. RESULTS: The mean age of patients was 54 years; 62 % were male and 38 % were female. Eleven patients underwent Type I Boston Kpro implantation as a primary procedure, while the other 52 patients had previous graft failure. The most frequent diagnoses were autoimmune diseases (16 eyes), severe chemical or thermal burn (12 eyes), leukoma post-infectious keratitis (seven eyes) and bullous keratopathy (six eyes). The mean follow-up time was 26 months. Retention of the prosthesis was achieved in 95 % at 1 year and 78 % at 4.5 years. Two eyes suffered extrusion of the KPro, six underwent successful exchange of the prosthesis either due to infection, necrosis or extrusion, three KPro's had to be explantated, and two eyes ended up in enucleation due to panophthalmitis. The outcome of the autoimmune cases was similar to the group with "other diagnoses" and better than those with chemical/thermal burn. The most frequent complication was development of a retroprosthetic membrane in 21 eyes (34 %). Visual acuity (LogMAR) in the chemical/thermal burn group was 2.30 preoperatively, 0.69 at 1 year, 0.52 at 2 years and 0.39 at 3 years; in the autoimmune group visual acuity was 2.3 preoperatively, 0.65 at 1 year, 0.15 at 2 years, and 1.5 at 3 years. CONCLUSIONS: Boston type 1 keratoprosthesis is a viable option for patients with repeated graft failure, even for those with challenging diagnoses such as ocular burns and autoimmune syndromes.


Assuntos
Bioprótese , Córnea , Doenças da Córnea/cirurgia , Sobrevivência de Enxerto/fisiologia , Implantação de Prótese , Acuidade Visual/fisiologia , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias , Prognóstico , Estudos Retrospectivos , Adulto Jovem
15.
Ophthalmic Res ; 52(1): 9-16, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-24853485

RESUMO

PURPOSE: To analyse how primary diagnosis and complications affect the evolution of post-operative visual acuity (VA). METHODS: We performed retrospective chart analysis on 59 eyes in 57 patients with various diagnoses, most of which were non-standard indications for Boston type 1 keratoprosthesis (Kpro) implantation. The follow-up period was at least 3 months. Patients were classified based on the evolution of post-operative VA: group A demonstrated stable VA improvement, group B lost VA improvement and group C no significant VA improvement. RESULTS: We assigned 46% of our cases to group A with stable VA improvement, 32% to group B with lost VA improvement, and 22% to group C with no VA improvement. The number of graft failures before Kpro implantation did not influence VA outcome. Except for the relatively good VA outcome in chemical burn and radiation injury patients, there seems to be no association between primary diagnosis and positive or negative VA outcome. Only 9% of patients with posterior segment complications and 20% with infections and associated pathologies were assigned to group A. CONCLUSION: Most cases (78%) showed improvement in VA after Boston type 1 Kpro (groups A and B). Posterior segment complications and infections mostly resulted in persistent loss of vision. These complications should be prevented and carefully treated.


Assuntos
Órgãos Bioartificiais , Córnea , Doenças da Córnea/diagnóstico , Doenças da Córnea/cirurgia , Complicações Pós-Operatórias , Acuidade Visual/fisiologia , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Criança , Pré-Escolar , Doenças da Córnea/fisiopatologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Prognóstico , Estudos Retrospectivos , Adulto Jovem
16.
Exp Eye Res ; 106: 5-13, 2013 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-23142516

RESUMO

Eye lenses from human donors with and without Alzheimer's disease (AD) were studied to evaluate the presence of amyloid in cortical cataract. We obtained 39 lenses from 21 postmortem donors with AD and 15 lenses from age-matched controls provided by the Banco de Ojos para Tratamientos de la Ceguera (Barcelona, Spain). For 17 donors, AD was clinically diagnosed by general physicians and for 4 donors the AD diagnosis was neuropathologically confirmed. Of the 21 donors with AD, 6 had pronounced bilateral cortical lens opacities and 15 only minor or no cortical opacities. As controls, 7 donors with pronounced cortical opacities and 8 donors with almost transparent lenses were selected. All lenses were photographed in a dark field stereomicroscope. Histological sections were analyzed using a standard and a more sensitive Congo red protocol, thioflavin staining and beta-amyloid immunohistochemistry. Brain tissue from two donors, one with cerebral amyloid angiopathy and another with advanced AD-related changes and one cornea with lattice dystrophy were used as positive controls for the staining techniques. Thioflavin, standard and modified Congo red staining were positive in the control brain tissues and in the dystrophic cornea. Beta-amyloid immunohistochemistry was positive in the brain tissues but not in the cornea sample. Lenses from control and AD donors were, without exception, negative after Congo red, thioflavin, and beta-amyloid immunohistochemical staining. The results of the positive control tissues correspond well with known observations in AD, amyloid angiopathy and corneas with lattice dystrophy. The absence of staining in AD and control lenses with the techniques employed lead us to conclude that there is no beta-amyloid in lenses from donors with AD or in control cortical cataracts. The inconsistency with previous studies of Goldstein et al. (2003) and Moncaster et al. (2010), both of which demonstrated positive Congo red, thioflavin, and beta-amyloid immunohistochemical staining in AD and Down syndrome lenses, is discussed.


Assuntos
Doença de Alzheimer/metabolismo , Peptídeos beta-Amiloides/metabolismo , Catarata/metabolismo , Córtex do Cristalino/metabolismo , Idoso , Idoso de 80 Anos ou mais , Doença de Alzheimer/patologia , Catarata/patologia , Angiopatia Amiloide Cerebral/metabolismo , Angiopatia Amiloide Cerebral/patologia , Feminino , Humanos , Imuno-Histoquímica , Córtex do Cristalino/patologia , Masculino , Coloração e Rotulagem , Doadores de Tecidos
17.
Graefes Arch Clin Exp Ophthalmol ; 251(1): 195-202, 2013 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-22527312

RESUMO

BACKGROUND: The aim of this study was to evaluate if iris color is associated with differences in visual functions such as intraocular straylight (IOSL), contrast sensitivity (CS), or best-corrected visual acuity (BCVA). METHODS: In this retrospective cohort study, which is a subgroup analysis of a large prospective trial about visual impairments in European car drivers, we included 853 persons between 20 and 80 years of age and without a history of ocular surgery or any eye disease including cataract. Subjects participated in an ophthalmological examination, grading of lens opacity, and the measurement of visual functions such as IOSL, CS, and BCVA. Dependent on iris color, participants were divided into four groups: light-blue, blue-grey, green-hazel, and brown. RESULTS: Independent of age, IOSL was significantly (all p values < 0.0001, Fisher's LSD test) higher in participants with light-blue colored iris (1.14 log(IOSL) [95 % CI: 1.11-1.17]) compared to participants with blue-grey (1.07 log(IOSL) [95 % CI: 1.05-1.09]), green-hazel (1.06 log(IOSL) [95 % CI: 1.04-1.08]) or brown (1.06 log(IOSL) [95 % CI: 1.04-1.08]) iris color. CS was also lower in participants with light-blue pigmented irises (1.60 log(CS) [95 % CI: 1.58-1.62]) than in the other groups, but statistically significant (p = 0.013, Fisher's LSD test) only compared to brown iris color. For BCVA we could not found any difference between the four groups. CONCLUSIONS: We could show in this study that iris color has a significant impact on IOSL and to a lower degree on CS, but not on BCVA. Persons with light-blue iris color who showed significantly higher IOSL values therefore may experience disability glare in daily situations such as driving at night more often than others.


Assuntos
Sensibilidades de Contraste/fisiologia , Cor de Olho/fisiologia , Espalhamento de Radiação , Acuidade Visual/fisiologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Estudos de Coortes , Feminino , Ofuscação , Humanos , Luz , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Adulto Jovem
18.
Invest Ophthalmol Vis Sci ; 62(1): 12, 2021 01 04.
Artigo em Inglês | MEDLINE | ID: mdl-33427852

RESUMO

Purpose: Human cortical opacities are most commonly accompanied by changes in lens fiber structure in the equatorial region at the lens nucleus-cortex interface. Cortex and nucleus have different elastic properties, which change with age. We therefore subjected ex vivo lenses to simulated accommodation and studied the internal deformations to better understand the mechanism of cortical cataract formation. Methods: Nine human donor lenses (33-88 years old) were tested using a bespoke radial stretching device for anterior eye segments. Seven of the lenses exhibited cortical cataracts. The other two lenses, without cataract, were used as controls. Frontal and cross-sectional images of the lens obtained during stretching facilitated measurements on equatorial lens diameter and central lens thickness in the stretched and unstretched states. Results: Stretching caused the lens equatorial diameter to increase in all cases. Conversely, the lens central thickness showed no systematic variation during stretching. For four of the lenses with cortical cataract, ruptures were observed during stretching at the nucleus-cortex boundary adjacent to the cortical cataracts. Ruptures were not observed in the control lenses or in the three other lenses with cortical cataract. Conclusions: Internal ruptures can occur in aged ex vivo lenses subjected to simulated disaccommodation. These ruptures occur at the nucleus-cortex interface; at this location, a significant stiffness discontinuity is expected to develop with age. It is hypothesized that ruptures occur in in vivo lenses during accommodation-or attempted accommodation.


Assuntos
Acomodação Ocular/fisiologia , Catarata/fisiopatologia , Córtex do Cristalino/fisiopatologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Fenômenos Biomecânicos , Catarata/diagnóstico por imagem , Estudos Transversais , Humanos , Córtex do Cristalino/diagnóstico por imagem , Pessoa de Meia-Idade , Fotografação , Ruptura Espontânea , Estresse Fisiológico , Doadores de Tecidos
19.
Acta Ophthalmol ; 99(6): e922-e928, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-33421330

RESUMO

PURPOSE: To identify the causes of failure of the different surgical corneal graft techniques: penetrating keratoplasty (PK), deep anterior lamellar keratoplasty (DALK), Descemet stripping automated endothelial keratoplasty (DSAEK) and Descemet membrane endothelial keratoplasty (DMEK). METHODS: This multicentric retrospective study enrolled a consecutive cohort of patients who had undergone any type of keratoplasty between 2001 and 2016. The clinical data were obtained from the patient's medical records, following ethical guidelines, permissions and data protection. The main outcome measured in the study was the cause of graft failure, defined as any irreversible loss of graft transparency capable of compromising vision. The main causes of graft failure were classified as follows: (A) primary graft failure (PGF), (B) immunological rejection, (C) non-rejection (which includes endothelial decompensation without rejection, IOP elevation/glaucoma, diseases of the ocular surface, recurrence of the primary disease, wound dehiscence/hypotonia and trauma, among others) and (D) specific causes of lamellar keratoplasty failure. A descriptive study of the obtained data was carried out. The distribution of the causes of failure was evaluated according to the type of corneal transplant. RESULTS: Our research included a cohort of 571 keratoplasty failures, of which 509 met the inclusion criteria. The analysis of the causes of the PK failure showed that immunological allograft rejection represented the main cause, with 28.2% of the failures, followed by surface diseases (17.8%) and endothelial decompensation without rejection (17.3%). For the PK re-grafts group, the main cause of failure was immunological allograft rejection (34.0%), followed by diseases of the ocular surface (18.5%). For the DALK group, the failures mainly occurred due to surface diseases such as limbal stem cell insufficiency, infectious keratitis, keratolysis or persistent epithelial defect (37.8%). However, the main reason for failure in the DSAEK group was endothelial decompensation without rejection (31.9%) while primary graft failure was the main cause of failure in the DMEK group (64.1%). CONCLUSION: The main reason for failure in PK was immunological allograft rejection, both in primary and secondary transplants. The leading causes for failure were diseases of the ocular surface in the DALK population, endothelial decompensation without rejection in DSAEK and primary graft failure in DMEK.


Assuntos
Doenças da Córnea/cirurgia , Transplante de Córnea/efeitos adversos , Previsões , Rejeição de Enxerto/etiologia , Acuidade Visual , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Aloenxertos/imunologia , Feminino , Seguimentos , Rejeição de Enxerto/diagnóstico , Rejeição de Enxerto/imunologia , Sobrevivência de Enxerto , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Adulto Jovem
20.
Biomater Sci ; 8(22): 6414, 2020 Nov 21.
Artigo em Inglês | MEDLINE | ID: mdl-33079082

RESUMO

Correction for 'Bacterial nanocellulose as a corneal bandage material: a comparison with amniotic membrane' by Irene Anton-Sales et al., Biomater. Sci., 2020, 8, 2921-2930, DOI: .

SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa