Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Luminescence ; 35(8): 1217-1222, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-32515166

RESUMO

The relative energy responses of three indigenously developed optically stimulated luminescence (OSL) phosphors in the disc form were studied in therapeutic photon and electron beams. Calibration in terms of absorbed dose was carried out in the dose range 5-500 cGy in 60 Co gamma rays, high energy X-rays, and electron beams used in radiotherapy. The combined standard uncertainty in the estimation of absorbed dose using these OSL discs (OSLDs) was 3.3%. Dose-response curves of these OSLDs in 60 Co gamma rays, 6 and 10 MV (flat and unflat), 15 MV and 6 and 15 MeV electron beams were found to be linear. Furthermore, these OSLDs exhibited a relative energy-dependent response for both photon and electron beams. The relative energy response correction factor for photon and electron beams were in the range 1.01-1.05 and 1.03-1.06, respectively.


Assuntos
Dosimetria por Luminescência Estimulada Opticamente , Dosímetros de Radiação , Elétrons , Luminescência , Fótons , Radiometria
2.
Luminescence ; 34(4): 444-449, 2019 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-31025441

RESUMO

Dental orthopantogram (OPG)/cone beam computed tomography (CBCT) scanners are gaining popularity due to their 3D imaging with multiplanar view that provides clinical benefits over conventional dental radiography systems. Dental OPG/CBCT provides optimal visualization of adjacent overlaying anatomical structures that will be superpositioned in any single projection. The characteristics of indigenously developed optically stimulated luminescence dosimeters, namely, aluminium oxide doped with carbon (Al2 O3 :C), lithium magnesium phosphate doped with terbium and boron (LiMgPO4 :Tb,B) and lithium calcium aluminium fluoride doped with europium and yttrium (LiCaAlF6 :Eu,Y) were evaluated for their use in dental dosimetry. The dose-response of these dosimeters was studied at X-ray energies 60 kV, 70 kV and 81 kV. Radiation doses were also measured using Gafchromic film for comparison. Radiation dose was measured at eight different locations of a polymethyl methacrylate (PMMA) head phantom including eyes. The optically stimulated luminescence (OSL) sensitivity of LiMgPO4 :Tb,B is about 1.5 times and LiCaAlF6 :Eu, is about 20 times higher than the sensitivity of Al2 O3 :C. It was found that measured radiation doses by the three optically stimulated luminescence dosimeters (OSLDs) and Gafchromic film in the occipital region (back side) of a PMMA phantom, were consistent but variations in dose at other locations were significantly higher. The three OSLDs used in this study were found to be suitable for radiation dose measurement in dental units.


Assuntos
Tomografia Computadorizada de Feixe Cônico , Equipamentos Odontológicos , Dosimetria por Luminescência Estimulada Opticamente , Dosímetros de Radiação , Tomografia Computadorizada de Feixe Cônico/instrumentação , Humanos , Dosimetria por Luminescência Estimulada Opticamente/instrumentação , Óptica e Fotônica , Doses de Radiação
3.
J Cancer Res Ther ; 19(Supplement): S0, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37147959

RESUMO

Aim: The aim of this study was to carried out the audit of radiotherapy centers practicing conformal radiotherapy techniques and demonstrate the suitability of this indigenous optically stimulated luminescence (OSL) disc dosimeters in beam quality audit and verification of patient-specific dosimetry in conventional and conformal treatments in radiotherapy. Materials and Methods: Dose audit in conventional and conformal (intensity-modulated radiotherapy and volumetric-modulated arc therapy) radiotherapy techniques was conducted using in-house developed Al2O3:C-based OSL disc dosimeter and commercially available Gafchromic EBT3 film in 6 MV (flat and unflat) photon and 6 and 15 MeV electron beams. OSL disc dosimeter and Gafchromic EBT3 film measured dose values were verified using the ionization chamber measurements. Results: Percentage variations of doses measured by OSL disc dosimeters and EBT3 Gafchromic film for conventional radiotherapy technique were in the range of 0.15%-4.6% and 0.40%-5.45%, respectively, with respect to the treatment planning system calculated dose values. For conformal radiotherapy techniques, the percentage variations of OSL disc and EBT3 film measured doses were in the range of 0.1%-4.9% and 0.3%-5.0%, respectively. Conclusion: The results of this study supported by statistical evidence provided the confidence that indigenously developed Al2O3:C-based OSL disc dosimeters are suitable for dose audit in conventional and advanced radiotherapy techniques.


Assuntos
Dosimetria por Luminescência Estimulada Opticamente , Dosímetros de Radiação , Humanos , Luminescência , Radiometria , Óxido de Alumínio
4.
Radiat Prot Dosimetry ; 189(1): 127-135, 2020 Jul 07.
Artigo em Inglês | MEDLINE | ID: mdl-32140728

RESUMO

Circular discs of diameter 5 mm were made from three indigenously developed optically stimulated luminescent (OSL) phosphors for medical dosimetry. Dosimetric characteristics of these discs were evaluated for their use in machine and patient-specific dosimetry in radiotherapy. Uncertainty in dosimetric measurements using these discs was also estimated, and combined standard uncertainty in measurement of absorbed dose was found to be 3.34%. Characterisation studies indicate that OSL discs are suitable for dosimetric application in radiotherapy. These discs were also used for patient-specific dosimetry in conventional and conformal radiotherapy treatments (five different cases) vis-à-vis ionisation chamber and Gafchromic EBT3 film. Doses measured by OSL discs were found comparable to ionisation chamber and Gafchromic EBT3 film measured values and radiotherapy treatment planning system (TPS) calculated dose values in all the cases. The variation between TPS calculated dose values and OSL discs measured dose values was found within the measurement uncertainty.


Assuntos
Dosimetria Fotográfica , Radiometria , Humanos , Luminescência
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa