Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Europace ; 25(6)2023 06 02.
Artigo em Inglês | MEDLINE | ID: mdl-37314196

RESUMO

AIMS: The standard implantable cardioverter defibrillator (ICD) generator (can) is placed in the left pectoral area; however, in certain circumstances, right-sided cans may be required which may increase defibrillation threshold (DFT) due to suboptimal shock vectors. We aim to quantitatively assess whether the potential increase in DFT of right-sided can configurations may be mitigated by alternate positioning of the right ventricular (RV) shocking coil or adding coils in the superior vena cava (SVC) and coronary sinus (CS). METHODS AND RESULTS: A cohort of CT-derived torso models was used to assess DFT of ICD configurations with right-sided cans and alternate positioning of RV shock coils. Efficacy changes with additional coils in the SVC and CS were evaluated. A right-sided can with an apical RV shock coil significantly increased DFT compared to a left-sided can [19.5 (16.4, 27.1) J vs. 13.3 (11.7, 19.9) J, P < 0.001]. Septal positioning of the RV coil led to a further DFT increase when using a right-sided can [26.7 (18.1, 36.1) J vs. 19.5 (16.4, 27.1) J, P < 0.001], but not a left-sided can [12.1 (8.1, 17.6) J vs. 13.3 (11.7, 19.9) J, P = 0.099). Defibrillation threshold of a right-sided can with apical or septal coil was reduced the most by adding both SVC and CS coils [19.5 (16.4, 27.1) J vs. 6.6 (3.9, 9.9) J, P < 0.001, and 26.7 (18.1, 36.1) J vs. 12.1 (5.7, 13.5) J, P < 0.001]. CONCLUSION: Right-sided, compared to left-sided, can positioning results in a 50% increase in DFT. For right-sided cans, apical shock coil positioning produces a lower DFT than septal positions. Elevated right-sided can DFTs may be mitigated by utilizing additional coils in SVC and CS.


Assuntos
Seio Coronário , Desfibriladores Implantáveis , Humanos , Veia Cava Superior/diagnóstico por imagem , Simulação por Computador , Ventrículos do Coração
2.
Europace ; 25(2): 469-477, 2023 02 16.
Artigo em Inglês | MEDLINE | ID: mdl-36369980

RESUMO

AIMS: Existing strategies that identify post-infarct ventricular tachycardia (VT) ablation target either employ invasive electrophysiological (EP) mapping or non-invasive modalities utilizing the electrocardiogram (ECG). Their success relies on localizing sites critical to the maintenance of the clinical arrhythmia, not always recorded on the 12-lead ECG. Targeting the clinical VT by utilizing electrograms (EGM) recordings stored in implanted devices may aid ablation planning, enhancing safety and speed and potentially reducing the need of VT induction. In this context, we aim to develop a non-invasive computational-deep learning (DL) platform to localize VT exit sites from surface ECGs and implanted device intracardiac EGMs. METHODS AND RESULTS: A library of ECGs and EGMs from simulated paced beats and representative post-infarct VTs was generated across five torso models. Traces were used to train DL algorithms to localize VT sites of earliest systolic activation; first tested on simulated data and then on a clinically induced VT to show applicability of our platform in clinical settings. Localization performance was estimated via localization errors (LEs) against known VT exit sites from simulations or clinical ablation targets. Surface ECGs successfully localized post-infarct VTs from simulated data with mean LE = 9.61 ± 2.61 mm across torsos. VT localization was successfully achieved from implanted device intracardiac EGMs with mean LE = 13.10 ± 2.36 mm. Finally, the clinically induced VT localization was in agreement with the clinical ablation volume. CONCLUSION: The proposed framework may be utilized for direct localization of post-infarct VTs from surface ECGs and/or implanted device EGMs, or in conjunction with efficient, patient-specific modelling, enhancing safety and speed of ablation planning.


Assuntos
Ablação por Cateter , Aprendizado Profundo , Taquicardia Ventricular , Humanos , Técnicas Eletrofisiológicas Cardíacas , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/etiologia , Taquicardia Ventricular/cirurgia , Eletrocardiografia/métodos , Infarto/cirurgia
3.
Front Physiol ; 12: 682446, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34276403

RESUMO

Background: Focal ventricular tachycardia (VT) is a life-threating arrhythmia, responsible for high morbidity rates and sudden cardiac death (SCD). Radiofrequency ablation is the only curative therapy against incessant VT; however, its success is dependent on accurate localization of its source, which is highly invasive and time-consuming. Objective: The goal of our study is, as a proof of concept, to demonstrate the possibility of utilizing electrogram (EGM) recordings from cardiac implantable electronic devices (CIEDs). To achieve this, we utilize fast and accurate whole torso electrophysiological (EP) simulations in conjunction with convolutional neural networks (CNNs) to automate the localization of focal VTs using simulated EGMs. Materials and Methods: A highly detailed 3D torso model was used to simulate ∼4000 focal VTs, evenly distributed across the left ventricle (LV), utilizing a rapid reaction-eikonal environment. Solutions were subsequently combined with lead field computations on the torso to derive accurate electrocardiograms (ECGs) and EGM traces, which were used as inputs to CNNs to localize focal sources. We compared the localization performance of a previously developed CNN architecture (Cartesian probability-based) with our novel CNN algorithm utilizing universal ventricular coordinates (UVCs). Results: Implanted device EGMs successfully localized VT sources with localization error (8.74 mm) comparable to ECG-based localization (6.69 mm). Our novel UVC CNN architecture outperformed the existing Cartesian probability-based algorithm (errors = 4.06 mm and 8.07 mm for ECGs and EGMs, respectively). Overall, localization was relatively insensitive to noise and changes in body compositions; however, displacements in ECG electrodes and CIED leads caused performance to decrease (errors 16-25 mm). Conclusion: EGM recordings from implanted devices may be used to successfully, and robustly, localize focal VT sources, and aid ablation planning.

4.
Comput Biol Med ; 125: 104005, 2020 10.
Artigo em Inglês | MEDLINE | ID: mdl-32971325

RESUMO

BACKGROUND: Pace-mapping is a commonly used electrophysiological (EP) procedure which aims to identify exit sites of ventricular tachycardia (VT) by matching ventricular activation patterns (assessed by QRS morphology) at specific pacing locations with activation during VT. However, long procedure durations and the need for VT induction render this technique non-optimal. To demonstrate the potential of in-silico pace-mapping, using stored electrogram (EGM) recordings of clinical VT from implanted devices to guide pre-procedural ablation planning. METHOD: Six scar-related VT episodes were simulated in a 3D torso model reconstructed from computed tomography (CT) imaging data, including three different infarct anatomies mapped from infarcted porcine imaging data. In-silico pace-mapping was performed to localise VT exit sites and isthmuses by using 12-lead electrocardiogram (ECG) signals and different combinations of EGM sensing vectors from implanted devices, through the creation of conventional correlation maps and reference-less maps. RESULTS: Our in-silico platform was successful in identifying VT exit sites for a variety of different VT morphologies from both ECG correlation maps and corresponding EGM maps, with the latter dependent upon the number of sensing vectors used. We also showed the added utility of both ECG and EGM reference-less pace-mapping for the identification of slow-conducting isthmuses, uncovering the optimal algorithm parameters. Finally, EGM-based pace-mapping was shown to be more dependent upon the mapped surface (epicardial/endocardial), relative to the VT origin. CONCLUSIONS: In-silico pace-mapping can be used along with EGMs from implanted devices to localise VT ablation targets in pre-procedural planning.


Assuntos
Ablação por Cateter , Taquicardia Ventricular , Animais , Eletrocardiografia , Eletrônica , Suínos , Taquicardia Ventricular/diagnóstico por imagem , Taquicardia Ventricular/cirurgia , Tronco
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa