Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
J Appl Physiol (1985) ; 96(5): 1899-908, 2004 May.
Artigo em Inglês | MEDLINE | ID: mdl-14966018

RESUMO

A respiration-gated synchrotron radiation computed tomography (SRCT) technique, which allows visualization and direct quantification of inhaled stable xenon gas, was used to study the effect of tidal volume (Vt) on regional lung ventilation. High-resolution maps (pixel size 0.35 x 0.35 mm) of local washin time constants (tau) and regional specific ventilation were obtained in five anesthetized, paralyzed, and mechanically ventilated rabbits in upright body position at the fourth, sixth, and eighth dorsal vertebral levels with a Vt from 4.9 +/- 0.3 to 7.9 +/- 0.4 ml/kg (means +/- SE). Increasing Vt without an increase in minute ventilation resulted in a proportional increase of mean specific ventilation up to 65% in all studied lung levels and reduced the scattering of washin tau values. The tau values had log-normal distributions. The results indicate that an increase in Vt decreases nonuniformity of intraregional ventilatory gas exchange. The findings suggest that (SRCT) provides a new quantitative tool with high spatial discrimination ability for assessment of changes in peripheral pulmonary gas distribution during mechanical ventilation.


Assuntos
Pulmão/fisiologia , Respiração , Mecânica Respiratória , Volume de Ventilação Pulmonar , Animais , Pulmão/diagnóstico por imagem , Masculino , Postura , Troca Gasosa Pulmonar , Coelhos , Respiração Artificial , Síncrotrons , Tomografia Computadorizada por Raios X , Xenônio
2.
Phys Med Biol ; 46(12): 3287-99, 2001 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-11768506

RESUMO

Small airways play a key role in the distribution of ventilation and in the matching of ventilation to perfusion. The purpose of this study was to introduce an imaging method that allows measurement of regional lung ventilation and evaluation of the function of airways with a small diameter. The experiments were performed at the Medical Beamline of the European Synchrotron Radiation Facility. Monochromatic synchrotron radiation beams were used to obtain quantitative respiration-gated images of lungs and airways in two anaesthetized and mechanically ventilated rabbits using inhaled stable xenon (Xe) gas as a contrast agent. Two simultaneous images were acquired at two different energies, above and below the K-edge of Xe. Logarithmic subtraction of the two images yields absolute Xe concentrations. This technique is known as K-edge subtraction (KES) radiography. Two-dimensional planar and CT images were obtained showing spatial distribution of Xe concentrations within the airspaces, as well as the dynamics of filling with Xe. Bronchi down to 1 mm in diameter were visible both in the subtraction radiographs and in tomographic images. Absolute concentrations of Xe gas were calculated within the tube carrying the inhaled gas mixture, small and large bronchi, and lung tissue. Local time constants of ventilation with Xe were obtained by following the evolution of gas concentration in sequential computed tomography images. The results of this first animal study indicate that KES imaging of lungs with Xe gas as a contrast agent has great potential in studies of the distribution of ventilation within the lungs and of airway function, including airways with a small diameter.


Assuntos
Meios de Contraste/farmacologia , Pulmão/patologia , Radiografia Torácica/métodos , Síncrotrons , Xenônio , Administração por Inalação , Animais , Meios de Contraste/administração & dosagem , Coelhos , Radiometria , Fatores de Tempo , Xenônio/administração & dosagem
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa