Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 74
Filtrar
1.
Catheter Cardiovasc Interv ; 102(2): 310-317, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37232290

RESUMO

BACKGROUND: The relationship between high postprocedural mean gradient (ppMG) and clinical events following mitral valve transcatheter edge-to-edge repair (MV-TEER) in patients with degenerative mitral regurgitation (DMR) is still debated. AIM: The purpose of this study was to evaluate the effect of elevated ppMG after MV-TEER on clinical events in patients with DMR at 1-year follow-up. METHODS: The study included 371 patients with DMR treated with MV-TEER enrolled in the "Multi-center Italian Society of Interventional Cardiology (GISE) registry of trans-catheter treatment of mitral valve regurgitation" (GIOTTO) registry. Patients were stratified in tertiles according to ppMG. Primary endpoint was a composite of all-cause death and hospitalization due to heart failure at 1-year follow-up. RESULTS: Patients were stratified as follows: 187 with a ppMG ≤ 3 mmHg, 77 with a ppMG > 3/=4 mmHg, and 107 with a ppMG > 4 mmHg. Clinical follow-up was available in all subjects. At multivariate analysis, neither a ppMG > 4 mmHg nor a ppMG ≥ 5 mmHg were independently associated with the outcome. Notably, the risk of elevated residual MR (rMR > 2+) was significantly higher in patients belonging to the highest tertile of ppMG (p = 0.009). The association of ppMG > 4 mmHg and rMR ≥ 2+ was strongly and independently associated with adverse events (hazard ratio: 1.98; 95% confidence interval: [1.10-3.58]). CONCLUSIONS: In a real-world cohort of patients suffering DMR and treated with MV-TEER, isolated ppMG was not associated with the outcome at 1-year follow-up. A high proportion of patients showed both elevated ppMG and rMR and their combination appeared to be a strong predictor of adverse events.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Insuficiência Cardíaca , Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Mitral , Humanos , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/cirurgia , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Resultado do Tratamento , Implante de Prótese de Valva Cardíaca/efeitos adversos
3.
Catheter Cardiovasc Interv ; 100(3): 451-460, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-35644994

RESUMO

BACKGROUND: Mitral-valve transcatheter edge-to-edge repair (MV-TEER) is recommended in patients with severe functional mitral regurgitation (FMR) and in those with degenerative mitral regurgitation (DMR) not eligible to traditional surgery. Patients with a history of previous cardiac surgery are considered at high risk for surgical reintervention, but data are lacking regarding procedural and clinical outcomes. OBJECTIVE: aim of this study was to assess the efficacy and clinical results of MV-TEER in patients with previous cardiac surgery enrolled in the "multicentre Italian Society of Interventional Cardiology registry of transcatheter treatment of mitral valve regurgitation" (GIOTTO). METHODS: Patients with previous coronary artery bypass grafting (CABG), surgical aortic valve replacement (AVR), or mitral valve repair (MVR) were included. Those with multiple or combined previous cardiac surgeries were excluded. Clinical follow-up was performed at 30 days, 1 year, and 2 years. The primary endpoint was a composite of death or rehospitalization at 1- and 2-year follow-ups. RESULTS: A total of 330 patients enrolled in the GIOTTO registry were considered (CABG 77.9%, AVR 14.2%, and MVR 7.9%). Most patients showed FMR (66.9%), moderate reduction of left ventricular (LV) ejection fraction, and signs of LV dilation. Procedural and device successes were 94.8% and 97%. At 1 and 2 years, the composite endpoint occurred are 29.1% and 52.4%, respectively. The composite outcome rates were similar across the three subgroups of previous cardiac surgery (p = 0.928) and between the FMR and DMR subgroups (p = 0.850) at 2 years. In a multivariate analysis, residual mitral regurgitation (rMR) ≥2+ was the main predictor of adverse events at 1 year (hazard ratio: 1.54 [95% confidence interval, CI: 1.00-2.38]; p = 0.050). This association was confirmed at 2 years of Kaplan-Meier analysis (p = 0.001). CONCLUSIONS: MV-TEER is effective in these patients, regardless of the subtype of previous cardiac surgery and the MR etiology. An rMR ≥2+ is independently associated with adverse outcomes at 1-year follow-up.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Mitral , Cateterismo Cardíaco , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/métodos , Humanos , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/etiologia , Insuficiência da Valva Mitral/cirurgia , Resultado do Tratamento
4.
Eur Heart J Suppl ; 22(Suppl L): L82-L85, 2020 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-33654471

RESUMO

Silent myocardial ischaemia (SMI) is defined as objective evidence of ischaemia without angina (or equivalent symptoms) in the presence of coronary artery disease, differing from silent coronary artery disease. Silent myocardial ischaemia represents the majority of episodes of myocardial ischaemia at Holter monitoring. During transient myocardial ischaemia, the symptoms appear after the contraction anomalies of the left ventricle and after the ECG changes. The cause of silent myocardial ischaemia is still not well established. The severity and duration of ischaemia have been theorized as important elements in the SMI mechanism. Another possible mechanism responsible for SMI is represented by changes in the perception of painful stimuli with an increased pain threshold. Finally, a neuronal dysfunction of the diabetic, in post-infarction or a cardiac neuronal 'stunning' could play a role in SMI. In the pre-stent era, the SMI was associated with a worse prognosis. In patients with diabetes mellitus, SMI seems to be more represented because autonomic dysfunction is present in this category of patients. In conclusion, SMI is more frequent than symptomatic ischaemia. However, despite the presence of countless studies on the subject, it is not clear today whether medical therapy has equalized the risk and what the real prognosis of SMI is.

5.
J Mol Cell Cardiol ; 134: 98-106, 2019 09.
Artigo em Inglês | MEDLINE | ID: mdl-31278905

RESUMO

Aortic valve tissue is largely exposed to high blood flow. Cells belonging to aortic valve tissues are able to detect and respond to flow conditions changes. Bicuspid aortic valve (BAV) presents altered morphology, with only two abnormal cusps instead of three. This results in an alteration of blood flow dynamics on valve cusps and aortic wall, which may, in turn, increase the risk to develop aortic stenosis and/or regurgitation, endocarditis, aortopathy and/or aortic dissection. MicroRNAs (miRNAs) are short RNA strands regulating gene expression mainly through the inhibition of their target mRNAs. They are largely involved in cardiovascular pathophysiology and heart disease. More recently, it has been observed that the expression of specific miRNAs can be modulated in response to changes in hemodynamic conditions. Using a bioinformatic approach, this article analyses available scientific evidence about the differential expression of miRNAs in the bicuspid aortic valve, with a focus on the differential modulation compared to the calcific-degenerative tricuspid aortic valve.


Assuntos
Valva Aórtica/anormalidades , Valva Aórtica/metabolismo , Doenças das Valvas Cardíacas/metabolismo , MicroRNAs/metabolismo , Animais , Aorta/metabolismo , Valva Aórtica/patologia , Estenose da Valva Aórtica/metabolismo , Doença da Válvula Aórtica Bicúspide , Calcinose/metabolismo , Cardiopatias/metabolismo , Hemodinâmica/fisiologia , Humanos , Camundongos
6.
Eur Heart J Suppl ; 19(Suppl D): D354-D369, 2017 May.
Artigo em Inglês | MEDLINE | ID: mdl-28751850

RESUMO

Aortic stenosis is one of the most frequent valvular diseases in developed countries, and its impact on public health resources and assistance is increasing. A substantial proportion of elderly people with severe aortic stenosis is not eligible to surgery because of the advanced age, frailty, and multiple co-morbidities. Transcatheter aortic valve implantation (TAVI) enables the treatment of very elderly patients at high or prohibitive surgical risk considered ineligible for surgery and with an acceptable life expectancy. However, a significant percentage of patients die or show no improvement in quality of life (QOL) in the follow-up. In the decision-making process, it is important to determine: (i) whether and how much frailty of the patient influences the risk of procedures; (ii) how the QOL and the individual patient's survival are influenced by aortic valve disease or from other associated conditions; and (iii) whether a geriatric specialist intervention to evaluate and correct frailty or other diseases with their potential or already manifest disabilities can improve the outcome of surgery or TAVI. Consequently, in addition to risk stratification with conventional tools, a number of factors including multi-morbidity, disability, frailty, and cognitive function should be considered, in order to assess the expected benefit of both surgery and TAVI. The pre-operative optimization through a multidisciplinary approach with a Heart Team can counteract the multiple damage (cardiac, neurological, muscular, respiratory, and kidney) that can potentially aggravate the reduced physiological reserves characteristic of frailty. The systematic application in clinical practice of multidimensional assessment instruments of frailty and cognitive function in the screening and the adoption of specific care pathways should facilitate this task.

7.
BMC Cardiovasc Disord ; 15: 169, 2015 Dec 11.
Artigo em Inglês | MEDLINE | ID: mdl-26654975

RESUMO

BACKGROUND: Adequate expansion is critical to achieve optimal Bioresorbable Vascular Scaffolds (BVS) apposition to the vessel wall. However, compared to metallic stents, BVS present different mechanical properties. Hence, slow deployment and maintenance of balloon inflation for at least 30" is recommended for BVS implantation. However, since no evidences are available demonstrating the superiority of a longer balloon dilatation time, the implantation technique is highly variable among different centers. METHODS: A total of 24 BVS-treated lesions were included in the present analysis. After BVS deployment at 12 atmosphere (ATM) the balloon was rapidly deflated and scaffold expansion was documented with an angiogram. The same balloon was then inflated again and kept at 12 ATM for 30". Finally, a further angiogram was obtained to evaluate BVS expansion. Quantitative coronary angiography (QCA) was performed at each step. RESULTS: A significant increase of minimal luminal diameter (MLD)-to-reference scaffold diameter (RSD) ratio (MLD to RSD Ration, MR-Ratio) from 0.70 ± 0.10 after initial stent deployment to 0.79 ± 0.10 after the 30"-long balloon dilation was observed (p < 0.001). Of note, this result was consistent across all sub-segments, as well as across almost all lesion subgroups. A substantial reduction in the prevalence of residual stenosis from 29 % to 17 % was registered after the 30"-long dilation. CONCLUSIONS: Our results strongly support the maintenance of balloon inflation for at least 30" during BVS deployment to achieve optimal scaffold expansion and minimize the occurrence of residual stenosis.


Assuntos
Implantes Absorvíveis , Angioplastia Coronária com Balão/instrumentação , Cateteres Cardíacos , Doença da Artéria Coronariana/terapia , Vasos Coronários , Idoso , Angioplastia Coronária com Balão/efeitos adversos , Angiografia Coronária , Doença da Artéria Coronariana/diagnóstico por imagem , Vasos Coronários/diagnóstico por imagem , Vasos Coronários/patologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Desenho de Prótese , Fatores de Tempo , Tomografia de Coerência Óptica , Resultado do Tratamento
10.
Am J Cardiol ; 211: 219-227, 2024 Jan 15.
Artigo em Inglês | MEDLINE | ID: mdl-37944779

RESUMO

Atrial functional mitral regurgitation (aFMR) has a peculiar pathophysiology that may have distinctive outcomes. We investigated the impact of transcatheter edge-to-edge repair in aFMR compared with other FMR etiologies. The GIOTTO (GIse registry Of Transcatheter treatment of MR) is a multicenter, prospective study enrolling patients with symptomatic MR treated with MitraClip up to 2020. We categorized patients with FMR as aFMR, ischemic FMR (iFMR), and nonischemic ventricular FMR (niFMR). The clinical end points were defined according to the Mitral Valve Academic Research Consortium. Of 1,153 patients, 6% had aFMR, 47% iFMR, and 47% niFMR. Patients with aFMR were older, mostly women, and had a higher atrial fibrillation rate. They had better left ventricular ejection fraction and smaller left ventricular volumes, with no difference in mitral effective regurgitant orifice area. The acute device and procedural success rates were similar among the groups. At the longest available follow-up (median 478 days, interquartile range 91 to 741 days), the rate of MR ≥2+ was similar among the groups. Patients with aFMR had a lower rate of cardiovascular death and heart failure than patients with iFMR (hazard ratio [HR] 0.43, p = 0.02) and niFMR (HR 0.45, p = 0.03). The aFMR etiology remained independently associated with the composite outcome, together with postprocedural MR ≤1+ (HR 0.63, p <0.01) and peripheral arteriopathy (HR 1.82, p = 0.003). The results of this GIOTTO subanalysis suggested that aFMR is less prevalent and associated with better outcomes compared with other causes of FMR treated by transcatheter edge-to-edge repair. Postprocedural MR >1+, peripheral vasculopathy, non-aFMR were independent predictors of worse outcomes.


Assuntos
Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Mitral , Humanos , Feminino , Masculino , Valva Mitral/cirurgia , Volume Sistólico , Estudos Prospectivos , Função Ventricular Esquerda , Sistema de Registros , Resultado do Tratamento , Implante de Prótese de Valva Cardíaca/métodos
11.
J Invasive Cardiol ; 36(8)2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38598251

RESUMO

OBJECTIVES: Transcatheter edge-to-edge repair (TEER) has become an established minimally invasive treatment for significant mitral regurgitation. Ongoing refinements and the availability of different clipping devices have expanded the indications for and effectiveness of TEER, but comprehensive comparative data on this issue are lacking. In this study, we compared NT, NTr, and XTr MitraClip devices (Abbot) for TEER. METHODS: Details on patient, imaging, and procedural details, as well as short- and long-term outcomes, were sought from a national prospective clinical registry on TEER with MitraClip. The primary outcome of interest was discharge after procedural success without major clinical complications. RESULTS: A total of 2236 patients were included, 1228 (54.9%) in whom NT implantation only was attempted, 233 (10.4%) in whom NTr but not XTr implantation was attempted, and 775 (34.7%) in whom XTr implantation was attempted. Clinical and imaging features differed substantially across the groups, reflecting expanding indications with NTr and XTr devices. In-hospital outcomes were largely similar among the 3 groups, including death. Long-term unadjusted estimates of effect showed significant differences in several outcomes, including death, rehospitalization, and their composite, which demonstrated that NT was associated with more unfavorable outcomes compared with the other devices (all P less than .05). However, most differences depended on baseline features, as adjusted analysis showed no significant differences for early as well as long-term outcomes, including long-term death, rehospitalization, and their composite (all P greater than .05). CONCLUSIONS: New-generation MitraClip devices are associated with favorable procedural and clinical outcomes, despite being used in patients with more adverse features, when compared with patients treated with previous devices.


Assuntos
Cateterismo Cardíaco , Insuficiência da Valva Mitral , Valva Mitral , Humanos , Insuficiência da Valva Mitral/cirurgia , Insuficiência da Valva Mitral/diagnóstico , Feminino , Masculino , Cateterismo Cardíaco/métodos , Idoso , Valva Mitral/cirurgia , Valva Mitral/diagnóstico por imagem , Resultado do Tratamento , Implante de Prótese de Valva Cardíaca/métodos , Implante de Prótese de Valva Cardíaca/instrumentação , Implante de Prótese de Valva Cardíaca/efeitos adversos , Idoso de 80 Anos ou mais , Estudos Prospectivos , Sistema de Registros , Ecocardiografia Transesofagiana/métodos , Seguimentos , Próteses Valvulares Cardíacas
12.
Clin Res Cardiol ; 2024 Jul 24.
Artigo em Inglês | MEDLINE | ID: mdl-39046472

RESUMO

BACKGROUND: To assess the interaction between heart failure (HF) severity and optimal reduction of secondary mitral regurgitation (SMR) on mortality in patients undergoing transcatheter edge-to-edge repair (M-TEER). METHODS AND RESULTS: Among 1656 patients included in the Italian Society of Interventional Cardiology (GIse) registry Of Transcatheter treatment of mitral valve regurgitaTiOn (GIOTTO) 984 had SMR and complete data on advanced HF. Advanced HF was defined as NYHA class III or IV, left ventricular ejection fraction ≤ 30%, and > 1 HF hospitalization during the last 12 months. Optimal M-TEER was defined as residual SMR ≤ 1 + at discharge. One hundred sixteen patients (11.8%) had advanced HF. Achievement of an optimal SMR reduction was similar in patients with and without advanced HF (65% and 60% respectively). Advanced HF was an independent predictor of 2-year all-cause death (adjusted HR 1.52, 95% CI 1.09-2.10). Optimal M-TEER, as compared to a no-optimal M-TEER, was associated with a reduced risk of death both in patients with advanced (HR 0.55, 95% CI 0.32-0.97; p = 0.039) and no-advanced HF (HR 0.59, 95% CI 0.46-0.78; p < 0.001; p = 0.778 for interaction). CONCLUSIONS: Advanced HF is associated with poor outcome in patients undergoing M-TEER. However, an optimal SMR reduction reduces the risk of 2-year mortality regardless of HF severity.

13.
J Am Heart Assoc ; 13(10): e033605, 2024 May 21.
Artigo em Inglês | MEDLINE | ID: mdl-38742523

RESUMO

BACKGROUND: Minimally invasive mitral valve repair has a favorable risk-benefit profile in patients with significant de novo mitral regurgitation. Its role in patients with prior mitral valve repair is uncertain. We aimed to appraise the outcome of patients undergoing transcatheter edge-to-edge repair (TEER) with prior transcatheter or surgical mitral valve repair (SMVR). METHODS AND RESULTS: We queried the Italian multicenter registry on TEER with MitraClip, distinguishing naïve patients from those with prior TEER or (SMVR). Inhospital and long-term clinical/echocardiographic outcomes were appraised. The primary outcome was the occurrence of death or rehospitalization for heart failure. A total of 2238 patients were included, with 2169 (96.9%) who were naïve to any mitral intervention, 29 (1.3%) with prior TEER, and 40 (1.8%) with prior SMVR. Several significant differences were found in baseline clinical and imaging features. Respectively, device success was obtained in 2120 (97.7%), 28 (96.6%), and 38 (95.0%, P=0.261) patients; procedural success in 2080 (95.9%), 25 (86.2%), and 38 (95.0%; P=0.047); and inhospital death in 61 (2.8%), 1 (3.5%), and no (P=0.558) patients. Clinical follow-up after a mean of 14 months showed similar rates of death, cardiac death, rehospitalization, rehospitalization for heart failure, and their composite (all P>0.05). Propensity score-adjusted analysis confirmed unadjusted analysis, with lower procedural success for the prior TEER group (odds ratio, 0.28 [95% CI, 0.09-0.81]; P=0.019) but similar odds ratios and hazard ratios for all other outcomes in the naïve, TEER, and SMVR groups (all P>0.05). CONCLUSIONS: In carefully selected patients, TEER can be performed using the MitraClip device even after prior TEER or SMVR.


Assuntos
Cateterismo Cardíaco , Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Mitral , Valva Mitral , Sistema de Registros , Humanos , Insuficiência da Valva Mitral/cirurgia , Insuficiência da Valva Mitral/mortalidade , Insuficiência da Valva Mitral/fisiopatologia , Insuficiência da Valva Mitral/diagnóstico por imagem , Masculino , Feminino , Idoso , Cateterismo Cardíaco/instrumentação , Cateterismo Cardíaco/métodos , Valva Mitral/cirurgia , Valva Mitral/diagnóstico por imagem , Valva Mitral/fisiopatologia , Implante de Prótese de Valva Cardíaca/instrumentação , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/métodos , Itália/epidemiologia , Idoso de 80 Anos ou mais , Readmissão do Paciente/estatística & dados numéricos , Falha de Tratamento , Próteses Valvulares Cardíacas , Anuloplastia da Valva Mitral/instrumentação , Anuloplastia da Valva Mitral/efeitos adversos , Resultado do Tratamento , Fatores de Tempo , Fatores de Risco , Insuficiência Cardíaca/mortalidade , Insuficiência Cardíaca/fisiopatologia , Insuficiência Cardíaca/cirurgia
14.
Int J Cardiol ; 413: 132317, 2024 Oct 15.
Artigo em Inglês | MEDLINE | ID: mdl-38986745

RESUMO

AIM: The aims of this study were: i) to report the prevalence of low-risk patients with degenerative mitral regurgitation (DMR) undergoing mitral transcatheter edge-to-edge repair (M-TEER) in a real-world setting; ii) to evaluate the prognostic significance of EuroSCORE II; iii) to determine whether an optimal M-TEER provides a mortality benefit regardless of EuroSCORE-II. METHODS: We analyzed data from the GIOTTO registry that enrolled patients undergoing M-TEER in Italy. We included only patients with DMR. Two groups were defined: patients with EuroSCORE<4% and with EuroSCORE≥4%. A further stratification according to variables included in the EuroSCORE-II was made. Interaction between EuroSCORE-II and optimal procedural success was evaluated. Outcome of interest was all-cause death at 2-year. RESULTS: Among 1659 patients prospectively enrolled in the GIOTTO registry, 657 had DMR, 364 with an EuroSCORE<4% (53%) and 311 with an EuroSCORE≥4% (47%). Patients with lower EuroSCORE were older with less comorbidities. All-cause mortality was higher in patients with EuroSCORE≥ vs <4%. EuroSCORE II ≥ 4% was independently associated with an increased risk of mortality (HR 2.36, 95%CI 1.28-4.38, p = 0.007). Among variables included in the EuroSCORE-II, Left Ventricular Ejection Fraction<35% and systolic Pulmonary Artery Pressure ≥ 50mmhg were independent predictors of clinical outcome. Two-year all-cause death was higher in patients without optimal MR reduction regardless of the calculated surgical risk (p for interaction 0.3). CONCLUSION: More than half of patients with DMR undergoing M-TEER had a Euroscore<4% with a median age of 81. An optimally successful M-TEER was associated with a lower mortality regardless of EuroSCORE.


Assuntos
Cateterismo Cardíaco , Insuficiência da Valva Mitral , Sistema de Registros , Humanos , Insuficiência da Valva Mitral/cirurgia , Insuficiência da Valva Mitral/epidemiologia , Insuficiência da Valva Mitral/mortalidade , Masculino , Feminino , Idoso , Prevalência , Cateterismo Cardíaco/métodos , Itália/epidemiologia , Resultado do Tratamento , Idoso de 80 Anos ou mais , Estudos Prospectivos , Fatores de Risco , Seguimentos , Implante de Prótese de Valva Cardíaca/tendências
15.
Am J Cardiol ; 228: 24-33, 2024 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-39097151

RESUMO

Transcatheter mitral edge-to-edge repair (TEER) with transcatheter devices has become a mainstay in the minimally invasive treatment of patients with severe mitral regurgitation at increased surgical risk. Despite its apparently favorable risk profile, there is uncertainty on the risk and features of cerebrovascular accidents (CVAs) early and long after transcatheter mitral valve repair. We aimed to appraise the incidence and predictors of CVA in patients who underwent TEER. We explicitly queried the data set of an ongoing multicenter prospective observational study dedicated to TEER with MitraClip (Abbott Vascular, Santa Clara, California). The incidence of CVAs after TEER was formally appraised, and we explored potential predictors of such events. Descriptive, bivariate, and diagnostic accuracy analyses were performed. Of 2,238 patients who underwent TEER, CVAs occurred in 33 patients (1.47% [95% confidence interval 1.02% to 2.06%]), including 6 (0.27% [0.10% to 0.58%]) in-hospital strokes and 27 events after discharge (0.99% [0.66% to 1.44%]), over a median follow-up of 14 months. Most CVAs were major ischemic strokes during and after the in-hospital phase. Overall, CVAs were more common in patients with atrial fibrillation (p = 0.018), renal dysfunction (p = 0.032), higher EuroSCORE II (p = 0.033), and, as expected, higher CHA2DS2-VASc score (p = 0.033), despite the limited prognostic accuracy of the score. Notably, the occurrence of CVA did not confer a significantly increased risk of long-term (p = 0.136) or cardiac death (p = 0.397). The incidence of CVA in patients who underwent TEER is low, with most events occurring after discharge and being associated with preexisting risk features. These findings, although reassuring on the safety of TEER, call for proactive antithrombotic therapy whenever CVA risk is increased before and after TEER.


Assuntos
Cateterismo Cardíaco , Insuficiência da Valva Mitral , Acidente Vascular Cerebral , Humanos , Masculino , Feminino , Insuficiência da Valva Mitral/cirurgia , Insuficiência da Valva Mitral/epidemiologia , Incidência , Idoso , Acidente Vascular Cerebral/epidemiologia , Acidente Vascular Cerebral/etiologia , Idoso de 80 Anos ou mais , Complicações Pós-Operatórias/epidemiologia , Estudos Prospectivos , Implante de Prótese de Valva Cardíaca , Fatores de Risco , Valva Mitral/cirurgia
16.
Curr Vasc Pharmacol ; 2023 Dec 08.
Artigo em Inglês | MEDLINE | ID: mdl-38073100

RESUMO

Large bore accesses refer to accesses with a diameter of 10 French or greater and are necessary for various medical devices, including those used in transcatheter aortic valve replacement, endovascular aneurysm repair stent-grafts, and percutaneous mechanical support devices. Notably, the utilization of these devices via femoral access is steadily increasing due to advancements in technology and implantation techniques, which are expanding the pool of patients suitable for percutaneous procedures. However, procedures involving large bore devices carry a high risk of bleeding and vascular complications (VCs), impacting both morbidity and long-term mortality. In this review article, we will first discuss the incidence, determinants, and prognostic impact of VCs in patients undergoing large bore access procedures. Subsequently, we will explore the strategies developed in recent years to minimize VCs, including techniques for optimizing vascular puncture through femoral cannulation, such as the use of echo-guided access cannulation and fluoroscopic guidance. Additionally, we will evaluate existing vascular closure devices designed for large bore devices. Finally, we will consider new pharmacological strategies aimed at reducing the risk of periprocedural access-related bleeding.

17.
J Cardiovasc Med (Hagerstown) ; 24(5): 308-312, 2023 05 01.
Artigo em Inglês | MEDLINE | ID: mdl-36957987

RESUMO

BACKGROUND: The acute adaptation of the nitinol-based stent frame self expandable valve to the aortic root after deployment is poorly understood. Accordingly, this study aimed to assess the occurrence, degree and determinants of acute adaptation of the nitinol-based stent frame self-expandable valves after implantation. METHODS: This is a single-site prospective registry including patients undergoing transcatheter aortic valve replacement (TAVR) with a widely used second-generation nitinol-based self-expandable device (Evolut R, Medtronic, Minneapolis, Minnesota, USA). We measured valve diameters at three different sections: distal (aortic) level, central (annulus) level and proximal (ventricular) level. Valve expansion was estimated by the difference between the diameters calculated immediately after valve deployment (A) and at the end of the procedure (B). The absolute and relative stent changes were defined as B-A and (B-A)/B∗100, respectively. A linear regression model was performed to test the association between the degree of valve extension at each segment with baseline and procedural characteristics. RESULTS: A total of 58 consecutive TAVR patients were included in this analysis, with a mean age of 82.12 ±â€Š5.28 years. Out of the total, 46% of the patients had chronic kidney disease, 32% had diabetes and 76% had dyslipidaemia. The mean procedural time was 28.11 ±â€Š11.6 min, with 53.45% of predilation. Postdilation was performed only in 3.5% of patients. Final stent diameters were significantly higher than those achieved immediately after valve implantation - an observation that was consistent for all the segments: 0.50 ±â€Š0.51 mm and 2.48 ±â€Š2.57% ( P  < 0.01) in the proximal, 0.46 ±â€Š0.57 mm and 2.39 ±â€Š2.96% ( P  < 0.01) in the central, as well as 0.58 ±â€Š0.59 mm and 2.14 ±â€Š2.14% ( P  < 0.01) at the distal segments. Postdilation significantly affected the expansion of the central segment, and, albeit not significantly, the proximal one, while no changes were observed for the distal portion of the platform. CONCLUSION: This is the first study to have documented a significant degree of the Evolut R self-expandable valve expansion after deployment. However, further studies are required to assess the short- and long-term time course of self-expandable valve enlargement and the clinical relevance of this finding.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Humanos , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Resultado do Tratamento , Desenho de Prótese
18.
EuroIntervention ; 18(17): 1408-1417, 2023 Apr 24.
Artigo em Inglês | MEDLINE | ID: mdl-36809256

RESUMO

BACKGROUND: A risk score was recently derived from the Cardiovascular Outcomes Assessment of the MitraClip Percutaneous Therapy for Heart Failure Patients with Functional Mitral Regurgitation (COAPT) Trial. However, external validation of this score is still lacking. AIMS: We aimed to validate the COAPT risk score in a large multicentre population undergoing mitral transcatheter edge-to-edge repair (M-TEER) for secondary mitral regurgitation (SMR). METHODS: The Italian Society of Interventional Cardiology (GIse) Registry of Transcatheter Treatment of Mitral Valve RegurgitaTiOn (GIOTTO) population was stratified according to COAPT score quartiles. The performance of the COAPT score for 2-year all-cause death or heart failure (HF) hospitalisation was evaluated in the overall population and in patients with or without a COAPT-like profile. RESULTS: Among the 1,659 patients included in the GIOTTO registry, 934 had SMR and complete data for a COAPT risk score calculation. The incidence of 2-year all-cause death or HF hospitalisation progressively increased through the COAPT score quartiles in the overall population (26.4% vs 44.5% vs 49.4% vs 59.7%; log-rank p<0.001) and COAPT-like patients (24.7% vs 32.4% vs 52.3% vs. 53.4%; log-rank p=0.004), but not in those with a non-COAPT-like profile. The COAPT risk score had poor discrimination and good calibration in the overall population, moderate discrimination and good calibration in COAPT-like patients and very poor discrimination and poor calibration in non-COAPT-like patients. CONCLUSIONS: The COAPT risk score has a poor performance in the prognostic stratification of real-world patients undergoing M-TEER. However, after application to patients with a COAPT-like profile, moderate discrimination and good calibration were observed.


Assuntos
Insuficiência Cardíaca , Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Mitral , Humanos , Insuficiência da Valva Mitral/cirurgia , Fatores de Risco , Hospitalização , Resultado do Tratamento
19.
Am J Cardiol ; 200: 178-187, 2023 08 01.
Artigo em Inglês | MEDLINE | ID: mdl-37331223

RESUMO

Despite the growing experience with MitraClip in the broad spectrum of mitral regurgitation (MR), limited data are available regarding the independent prognostic role on survival of different mitral regurgitation etiology subtypes. We sought to evaluate the impact of flail leaflet etiology in a large series of patients with primary MR (PMR) who underwent MitraClip treatment. The study included 588 patients with significant PMR from the multicenter GIOTTO (Italian Society of Interventional Cardiology [GIse] registry Of Transcatheter treatment of mitral valve regurgitaTiOn), stratified into 2 groups according to MR etiology: flail+ (n = 300) and flail- (n = 288). The primary end point was a composite of cardiac death and first rehospitalization for heart failure (HF). To account for the baseline differences, patients were propensity score-matched 1:1. Flail leaflet etiology was present in about a half of the patients. Acute technical success was achieved in 98% of the overall cohort, with no significant differences between the study groups (p = 0.789). At the 2-year Kaplan-Meier analysis, the primary end point occurred in 13% of flail+ patients compared with 23% in flail- (p = 0.009). The flail+ group presented lower rates of both cardiac death and rehospitalization for HF, whereas a similar overall death rate was observed between the groups. A multivariate Cox regression analysis identified flail leaflet etiology as an independent predictor of favorable outcome in terms of the primary end point (hazard ratio 0.141, 95% confidence interval 0.049 to 0.401, p <0.001). After propensity score matching, flail+ patients had confirmed lower rates of cardiac mortality and rehospitalization for HF but similar rates of overall death. In conclusion, flail leaflet-related etiology was common in patients with PMR who underwent MitraClip treatment and was an independent predictor of midterm favorable clinical outcomes.


Assuntos
Insuficiência Cardíaca , Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Mitral , Humanos , Prognóstico , Resultado do Tratamento , Modelos de Riscos Proporcionais , Insuficiência Cardíaca/complicações , Morte , Implante de Prótese de Valva Cardíaca/efeitos adversos , Cateterismo Cardíaco/efeitos adversos
20.
Panminerva Med ; 65(4): 443-453, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37259492

RESUMO

BACKGROUND: The clinical impact of coronary artery disease (CAD) on the prognosis of patients undergoing MitraClip implantation is still unclear. METHODS: One thousand nine hundred fifty-three patients undergoing MitraClip implantation included in the multicenter GIOTTO Registry were stratified according to CAD. Endpoints were all-cause death, cardiac death, and re-hospitalization for heart failure at follow-up (median 15.8 months). RESULTS: Although younger, CAD patients were more symptomatic, had worse cardiovascular risk profile, higher burden of comorbidities, more frequently affected by functional MR, with higher left ventricle (LV) diameters and lower ejection fraction (EF). At follow-up, CAD patients showed higher rates of all-cause death (25.4% vs. 19.6%; P=0.002), cardiovascular death (14.0% vs. 10.1%; P=0.007) and re-hospitalization for heart failure (13.9% vs. 10.2%; P=0.011). Dividing the population according to mitral regurgitation (MR) etiology (functional vs. non-functional MR), no differences were observed between CAD and no-CAD patients. At multivariate logistic regression, NYHA III/IV class, prior heart failure hospitalization, severe chronic kidney disease, atrial fibrillation, LV end-diastolic diameter and LVEF<30% but not CAD resulted independent predictors of all-cause death. The same finding was confirmed even after propensity score adjustment. CONCLUSIONS: CAD did not show a relevant impact on mid-term prognosis per se, but seemed to identify a more complex and diseased cohort of patients with worse clinical and functional status.


Assuntos
Doença da Artéria Coronariana , Insuficiência Cardíaca , Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Mitral , Humanos , Doença da Artéria Coronariana/complicações , Doença da Artéria Coronariana/cirurgia , Insuficiência Cardíaca/complicações , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/métodos , Valva Mitral/cirurgia , Insuficiência da Valva Mitral/cirurgia , Insuficiência da Valva Mitral/etiologia , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa