Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 62
Filtrar
1.
Braz J Cardiovasc Surg ; 38(5): e20220332, 2023 08 04.
Artigo em Inglês | MEDLINE | ID: mdl-37540601

RESUMO

INTRODUCTION: Risk factors and postoperative complications can worsen the condition of patients undergoing coronary artery bypass grafting; some of these factors and complications are closely related to mortality rate. OBJECTIVE: To describe clinical factors and outcomes related to mortality of patients undergoing coronary artery bypass grafting and on invasive mechanical ventilation. METHODS: This is a single-center retrospective data analysis of patients who underwent coronary artery bypass grafting on invasive mechanical ventilation between 2013 and 2019. Data regarding clinical characteristics, postoperative complications, intensive care unit and mechanical ventilation time, and their relationship with mortality were analyzed. RESULTS: Four hundred seventy-two patients who underwent coronary artery bypass grafting entered the study. Their mean age was 62.3 years, and mean body mass index was 27.3. The mortality rate was 4%. Fifty percent of the patients who had ventilator-associated pneumonia died. Considering the patients who underwent hemotherapy and hemodialysis, 20% and 33% died, respectively. Days of intensive care unit stay and high Acute Physiology and Chronic Health Evaluation score and Simplified Acute Physiology Score were significantly related to death. CONCLUSION: Factors and clinical conditions such as the patients' age, associated comorbidities, the occurrence of ventilator-associated pneumonia, length of stay in the intensive care unit, and mechanical ventilation time are related to higher mortality in patients undergoing coronary artery bypass grafting.


Assuntos
Pneumonia Associada à Ventilação Mecânica , Humanos , Pessoa de Meia-Idade , Estudos Retrospectivos , Revascularização Miocárdica , Complicações Pós-Operatórias , Período Pós-Operatório , Resultado do Tratamento , Tempo de Internação
2.
Lung India ; 39(6): 502-509, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36629228

RESUMO

Background: Bronchiectasis is frequently identified in patients with COPD, especially in severe patients, but the relevance of this finding remains unclear. We aimed to investigate the factors that would increase the chance of having bronchiectasis in patients with severe COPD. Methods: This is an analytical, observational, cross-sectional study. Patients with severe COPD with (BC group) and without bronchiectasis (NBC group) were clinically evaluated and performed spirometry, 6-minute walk test (6MWT), volumetric capnography (VCap) and high resolution computed tomography (CT). CT was scored for the findings, and multiple linear regression was performed to identify variables related to the score's severity and logistic regression in order to identify factors that could be associated with the presence of bronchiectasis. Results: There was no significant difference between BC and NBC groups regarding clinical variables, except in the smoking load, which was lower in the BC group. In functional evaluation, NBC patients walked shorter distances in 6MWT (P < 0.005). In the BC group the distribution of CT findings was mostly bilateral and in lower lobes. Using the multiple linear regression analysis within the BC group, we found that the higher the bronchiectasis score, the higher ΔSpO2 during the 6MWT and the lower the FVC. The chance of having bronchiectasis was 4.78 times higher in the presence of positive isolates (sputum) (CI 1.35-16.865; P = 0.023). The higher the distance covered (6MWT) and Slp3 (VCap), (OR 1.01, CI 1.004; 1.0202, P = 0.0036; OR 1.04, CI 1.003; 1.077; P = 0.036), the greater are likelihood of bronchiectasis. Conclusions: In patients with COPD and bronchiectasis, higher CT scores were associated with worse lung function and a greater drop in oxygenation during exercise.

3.
Arq Gastroenterol ; 59(3): 383-389, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36102436

RESUMO

BACKGROUND: Capnography and carbon dioxide (CO2) insufflation during gastrointestinal endoscopy under sedation are associated with safety and comfort improvements, respectively. Capnography can provide early detection of apnea and hypoxemia, whereas CO2 insufflation causes lower periprocedural discomfort. This is the first study to report the application of volumetric capnography in colonoscopy. OBJECTIVE: This study aimed to evaluate the use of volumetric capnography with room air (RA) and CO2 insufflation during routine colonoscopy. METHODS: In this prospective cohort study, 101 patients who underwent routine colonoscopy under sedation with volumetric capnography monitoring were included. Insufflation with RA was used to distend the intestinal lumen in group 1 (n=51), while group 2 (n=50) used CO2 insufflation. The primary endpoints were episodes of hypoxia, alveolar hypoventilation, and end-tidal CO2 (EtCO2). The secondary endpoints were tidal volume per minute, consumption of sedation medications, and post-procedure pain using the Gloucester modified pain scale. RESULTS: The number of episodes of hypoxia (SpO2<90%) was similar between the groups: four episodes in Group 1 and two episodes in Group 2. The duration of hypoxia was significantly longer in group 2 (P=0.02). Hypoalveolar ventilation (EtCO2) occurred more frequently in Group 2 than in Group 1 (27 vs 18 episodes, P=0.05). Regarding EtCO2, Group 2 showed higher values in cecal evaluation (28.94±4.68 mmHg vs 26.65±6.12 mmHg, P=0.04). Regarding tidal volume per minute, Group 2 had significantly lower values at the cecal interval compared to Group 1 (2027.53±2818.89 vs 970.88±1840.25 L/min, P=0.009). No episodes of hypercapnia (EtCO2 > 60 mmHg) occurred during the study. There was no difference in the consumption of sedation medications between the groups. Immediately after colonoscopy, Group 2 reported significantly less pain than Group 1 (P=0.05). CONCLUSION: In our study, volumetric capnography during colonoscopy was feasible and effective for monitoring ventilatory parameters and detecting respiratory complications. CO2 insufflation was safe and associated with less pain immediately after colonoscopy.


Assuntos
Insuflação , Capnografia , Dióxido de Carbono , Colonoscopia/efeitos adversos , Colonoscopia/métodos , Humanos , Hipóxia/diagnóstico , Insuflação/efeitos adversos , Insuflação/métodos , Dor , Estudos Prospectivos
4.
Hematol Transfus Cell Ther ; 43(4): 443-452, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-32967805

RESUMO

INTRODUCTION: Inspiratory muscle training (IMT) has been shown to be an efficient method of improving exercise tolerance and inspiratory and expiratory muscle strength in several diseases. The effects of IMT on patients with sickle cell anemia (SCD) are relatively unknown. Our study aimed to evaluate the effects of IMT on adult SCD patients, regarding respiratory muscle strength (RMS) variables, lung function, exercise tolerance, blood lactation concentration, limitation imposed by dyspnea during daily activities and impact of fatigue on the quality of life. METHODS: This was a randomized single-blind study, with an IMT design comprising true load (TG) and sham load (SG) groups. Initial assessment included spirometry, volumetric capnography (VCap) and measurement of RMS by maximal inspiratory and expiratory pressure (PImax and PEmax). The Medical Research Council dyspnea scale and modified fatigue impact scale were also applied and blood lactate concentration was measured before and after the 6-minute walk test. After this initial assessment, the patient used the IMT device at home daily, returning every 6 weeks for RMS reassessment. Both groups used the same device and were unaware of which group they were in. After a period totaling 18 weeks, patients underwent the final evaluation, as initially performed. RESULTS: Twenty-five patients in total participated until the end of the study (median age 42 years). There were no significant differences between TG and SG based on age, sex, body mass index or severity of genotype. At the end of the training, both groups showed a significant increase in PEmax and PImax, improvement in Vcap and in exercise tolerance and dyspnea reduction while performing daily life activities. The same was observed in patients grouped according to disease severity (HbSS and HbSß0vs HbSC and HbSß+), without differences between groups. CONCLUSION: Home-based inspiratory muscle training benefits outpatients with SCD, including the sham load group. TRIAL REGISTRATION: http://www.ensaiosclinicos.gov.br; registration number: RBR-6g8n92.

5.
Sao Paulo Med J ; 139(5): 505-510, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34378739

RESUMO

BACKGROUND: The mechanism of exercise limitation in idiopathic pulmonary arterial hypertension (IPAH) is not fully understood. The role of hemodynamic alterations is well recognized, but mechanical, ventilatory and gasometric factors may also contribute to reduction of exercise capacity in these individuals. OBJECTIVE: To investigate whether there is an association between ventilatory pattern and stress Doppler echocardiography (SDE) variables in IPAH patients. DESIGN AND SETTING: Single-center prospective study conducted in a Brazilian university hospital. METHODS: We included 14 stable IPAH patients and 14 age and sex-matched controls. Volumetric capnography (VCap), spirometry, six-minute walk test and SDE were performed on both the patients and the control subjects. Arterial blood gases were collected only from the patients. The IPAH patients and control subjects were compared with regard to the abovementioned variables. RESULTS: The mean age of the patients was 38.4 years, and 78.6% were women. The patients showed hypocapnia, and in spirometry 42.9% presented forced vital capacity (FVC) below the lower limit of normality. In VCap, IPAH patients had higher respiratory rates (RR) and lower elimination of CO2 in each breath. There was a significant correlation between reduced FVC and the magnitude of increases in tricuspid regurgitation velocity (TRV). In IPAH patients, VCap showed similar tidal volumes and a higher RR, which at least partially explained the hypocapnia. CONCLUSIONS: The patients with IPAH showed hypocapnia, probably related to their higher respiratory rate with preserved tidal volumes; FVC was reduced and this reduction was positively correlated with cardiac output.


Assuntos
Hipertensão Arterial Pulmonar , Adulto , Estudos Transversais , Ecocardiografia sob Estresse , Teste de Esforço , Hipertensão Pulmonar Primária Familiar , Feminino , Humanos , Pulmão/diagnóstico por imagem , Estudos Prospectivos
6.
J Pediatr (Rio J) ; 96(2): 255-264, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-30529075

RESUMO

OBJECTIVE: To compare the values of the markers for volumetric capnography and spirometry and their ability to classify children and adolescents with asthma, cystic fibrosis (CF), and healthy controls. METHODS: This was a cross-sectional study that included 103 patients with controlled persistent allergic asthma, 53 with CF and a healthy control group with 40 volunteers (aged 6 to 15 years), of both sexes. The individuals underwent volumetric capnography and spirometry. RESULTS: Phase III slope (SIII), SIII standardized by exhaled tidal volume (SIII/TV) and capnographic index (SIII/SII)×100 (KPIv) were different among the three groups assessed, with highest values for CF. The relation between the forced expiratory volume in one second and the forced vital capacity (FEV1/FVC) was the only spirometric marker that presented difference on the three groups. On individuals with normal spirometry, KPIv and FEV1/FVC were different among the three groups. The ROC curve identified the individuals with asthma or CF from the control group, both through volumetric capnography (better to identify CF in relation to the control using KPIv) and through spirometry (better to identify asthma in relation to the control). KPIv was the best parameter to distinguish asthma from CF, even in individuals with normal spirometry. CONCLUSION: Volumetric capnography and spirometry identified different alterations in lung function on asthma, CF, and healthy controls, allowing the three groups to be distinguished.


Assuntos
Asma , Fibrose Cística , Adolescente , Capnografia , Criança , Estudos Transversais , Feminino , Volume Expiratório Forçado , Humanos , Masculino , Espirometria , Capacidade Vital
7.
Blood Press ; 18(5): 255-60, 2009.
Artigo em Inglês | MEDLINE | ID: mdl-19919396

RESUMO

This study was designed to evaluate the changes in arterial blood pressure (BP) and heart rate (HR) in moderate smokers during smoking abstinence after 7 days of treatment with bupropion alone, transdermal nicotine or bupropion combined with transdermal nicotine. Twenty-four healthy moderate smokers (12 female/12 male; 40+/-7 years) were evaluated randomly on five occasions and their systolic, diastolic, mean arterial blood pressure (MAP) and HR were measured by a Finapres device for 10 h, immediately after smoking interruption. All of the 24 smokers participated on five protocols during 7 days: control group (C) - no drugs; placebo group (PL); bupropion group (BUP) 150-300 mg; transdermal nicotine group (TN) - 21 mg; and BUP+TN-nicotine patch. Concomitantly, the subjects were evaluated by ABPM (ambulatory BP monitoring). All of BP parameters monitored shown significant statistical differences in the BUP, TN and BUP+TN groups compared with the controls (p<0.05), when measured by Finapres. The HR remained unaltered in all of the groups. No significant differences were seen in the BP or HR during the 24-h ABPM. These findings indicate that in moderate smokers, bupropion, transdermal nicotine or bupropion associated with transdermal nicotine caused an elevation in the BP after acute smoking interruption.


Assuntos
Pressão Sanguínea/efeitos dos fármacos , Bupropiona/administração & dosagem , Nicotina/administração & dosagem , Abandono do Hábito de Fumar/métodos , Fumar/fisiopatologia , Adulto , Bupropiona/efeitos adversos , Estudos Cross-Over , Feminino , Frequência Cardíaca/efeitos dos fármacos , Humanos , Masculino , Pessoa de Meia-Idade , Nicotina/efeitos adversos , Método Simples-Cego , Fatores de Tempo , Resultado do Tratamento
8.
Einstein (Sao Paulo) ; 18: eAO4805, 2019.
Artigo em Inglês, Português | MEDLINE | ID: mdl-31644676

RESUMO

OBJECTIVE: To simulate different diameters of endotracheal tubes and to verify the fluid dynamics aspects by means of flow and resistance measurements. METHODS: Fluid dynamics software was used to calculate mean flow and airway resistance in endotracheal tube with a diameter of 6.0, 7.0, 7.5, 8.0, 9.0 and 10.0mm at normal body temperature and under constant pressure. The same measurements were taken in the fusion of the first 22cm of a 9.0mm endotracheal tube with 10.0mm diameter, and with the end part in 12cm of a 6.0mm endotracheal tube with 7.0mm diameter. RESULTS: The fusion of the first 22cm of an endotracheal tube of 10.0mm diameter with the terminal part in 12cm of an endotracheal tube of 6.0mm diameter, preserving the total length of 34cm, generated average flow and airway resistance similar to that of a conventional 7.5mm endotracheal tube. CONCLUSION: This simulation study demonstrates that a single-sized endotracheal tube may facilitate endotracheal intubation without causing increased airway resistance.


Assuntos
Simulação por Computador , Desenho de Equipamento/instrumentação , Intubação Intratraqueal/instrumentação , Resistência das Vias Respiratórias , Intubação Intratraqueal/métodos , Respiração Artificial/instrumentação
9.
Sao Paulo Med J ; 137(2): 177-183, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-29340500

RESUMO

BACKGROUND: Excess trunk body fat in obese individuals influences respiratory physiological function. The aims of this study were to compare volumetric capnography findings (VCap) between severely obese patients and normal-weight subjects and to assess whether there is any association between neck circumference (NC), waist-hip ratio (WHR) and VCap among grade III obese individuals. DESIGN AND SETTING: Analytical observational case-matched cross-sectional study, University of Campinas. METHODS: This cross-sectional study compared VCap variables between 60 stage III obese patients and 60 normal-weight individuals. RESULTS: In comparison with the normal-weight group, obese patients presented higher alveolar minute volume (8.92 ± 4.94 versus 6.09 ± 2.2; P = < 0.0001), CO2 production (278 ± 91.0 versus 209 ± 60.23; P < 0.0001), expiratory tidal volume (807 ± 365 versus 624 ± 202; P = 0.005), CO2 production per breath (21.1 ± 9.7 versus 16.7 ± 6.16; P = 0.010) and peak expiratory flow (30.9 ± 11.9 versus 25.5 ± 9.13; P = 0.004). The end-expiratory CO2 (PetCO2) concentration (33.5 ± 4.88 versus 35.9 ± 3.79; P = 0.013) and the phase 3 slope were normalized according to expired tidal volume (0.02 ± 0.05 versus 0.03 ± 0.01; P = 0.049) were lower in the obese group. CONCLUSIONS: The greater the NC was, the larger were the alveolar minute volume, anatomical dead space, CO2 production per minute and per breath and expiratory volume; whereas the smaller were the phase 2 slope (P2Slp), phase 3 slope (P3Slp) and pressure drop in the mouth during inspiration.


Assuntos
Obesidade Mórbida/fisiopatologia , Ventilação Pulmonar/fisiologia , Volume de Ventilação Pulmonar/fisiologia , Adulto , Idoso , Capnografia , Estudos de Casos e Controles , Estudos Transversais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Espirometria , Relação Cintura-Quadril , Adulto Jovem
10.
J Laparoendosc Adv Surg Tech A ; 29(10): 1271-1275, 2019 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-31483185

RESUMO

Background: Increased intra-abdominal pressure resulting from pneumoperitoneum can cause renal physiological changes, such as oliguria and anuria, in mammals. Although videolaparoscopic operations are common, the occurrence of renal lesions due to these procedures has not been precisely documented in the literature. The aim of this study was to evaluate the impact of pneumoperitoneum on renal blood flow using renal scintigraphy in a rabbit model. Methods: Six New Zealand male rabbits weighing 3 kg, previously anesthetized, were mechanically ventilated and underwent pneumoperitoneum. Each animal served as its own control and was analyzed in two different moments: [99mTc] diethylenetriaminepentaacetic acid (DTPA) renal blood flow evaluation in baseline conditions (T0) and 30 minutes after installation of 15 mmHg-pneumoperitoneum (T1). The animals were monitored throughout the study by capnography, oximetry, and arterial pressure median, and were euthanized at the end of the experiment. Results: The quantitative analysis of the scintigraphic images of renal uptake of the radiopharmaceutical evidence reduced renal arterial blood flow during pneumoperitoneum. Compared with baseline conditions, all animals presented a reduction of renal blood flow varying from 16% to 82%, with mean [±standard deviation] of 53% [±24%]. Conclusions: Pneumoperitoneum induces a significant reduction of the renal blood flow, as determined in this experimental method in rabbits and dynamic renal scintigraphy with [99mTc] DTPA is an adequate method to investigate this event in the experimental setting.


Assuntos
Rim/diagnóstico por imagem , Pneumoperitônio Artificial/efeitos adversos , Circulação Renal/fisiologia , Animais , Rim/irrigação sanguínea , Testes de Função Renal , Masculino , Coelhos , Cintilografia , Compostos Radiofarmacêuticos , Pentetato de Tecnécio Tc 99m
11.
Rev. bras. cir. cardiovasc ; 38(5): e20220332, 2023. tab, graf
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1449565

RESUMO

ABSTRACT Introduction: Risk factors and postoperative complications can worsen the condition of patients undergoing coronary artery bypass grafting; some of these factors and complications are closely related to mortality rate. Objective: To describe clinical factors and outcomes related to mortality of patients undergoing coronary artery bypass grafting and on invasive mechanical ventilation. Methods: This is a single-center retrospective data analysis of patients who underwent coronary artery bypass grafting on invasive mechanical ventilation between 2013 and 2019. Data regarding clinical characteristics, postoperative complications, intensive care unit and mechanical ventilation time, and their relationship with mortality were analyzed. Results: Four hundred seventy-two patients who underwent coronary artery bypass grafting entered the study. Their mean age was 62.3 years, and mean body mass index was 27.3. The mortality rate was 4%. Fifty percent of the patients who had ventilator-associated pneumonia died. Considering the patients who underwent hemotherapy and hemodialysis, 20% and 33% died, respectively. Days of intensive care unit stay and high Acute Physiology and Chronic Health Evaluation score and Simplified Acute Physiology Score were significantly related to death. Conclusion: Factors and clinical conditions such as the patients' age, associated comorbidities, the occurrence of ventilator-associated pneumonia, length of stay in the intensive care unit, and mechanical ventilation time are related to higher mortality in patients undergoing coronary artery bypass grafting.

12.
Arq. gastroenterol ; 59(3): 383-389, July-Sept. 2022. tab, graf
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1403491

RESUMO

ABSTRACT Background: Capnography and carbon dioxide (CO2) insufflation during gastrointestinal endoscopy under sedation are associated with safety and comfort improvements, respectively. Capnography can provide early detection of apnea and hypoxemia, whereas CO2 insufflation causes lower periprocedural discomfort. This is the first study to report the application of volumetric capnography in colonoscopy. Objective: This study aimed to evaluate the use of volumetric capnography with room air (RA) and CO2 insufflation during routine colonoscopy. Methods: In this prospective cohort study, 101 patients who underwent routine colonoscopy under sedation with volumetric capnography monitoring were included. Insufflation with RA was used to distend the intestinal lumen in group 1 (n=51), while group 2 (n=50) used CO2 insufflation. The primary endpoints were episodes of hypoxia, alveolar hypoventilation, and end-tidal CO2 (EtCO2). The secondary endpoints were tidal volume per minute, consumption of sedation medications, and post-procedure pain using the Gloucester modified pain scale. Results: The number of episodes of hypoxia (SpO2<90%) was similar between the groups: four episodes in Group 1 and two episodes in Group 2. The duration of hypoxia was significantly longer in group 2 (P=0.02). Hypoalveolar ventilation (EtCO2) occurred more frequently in Group 2 than in Group 1 (27 vs 18 episodes, P=0.05). Regarding EtCO2, Group 2 showed higher values in cecal evaluation (28.94±4.68 mmHg vs 26.65±6.12 mmHg, P=0.04). Regarding tidal volume per minute, Group 2 had significantly lower values at the cecal interval compared to Group 1 (2027.53±2818.89 vs 970.88±1840.25 L/min, P=0.009). No episodes of hypercapnia (EtCO2 > 60 mmHg) occurred during the study. There was no difference in the consumption of sedation medications between the groups. Immediately after colonoscopy, Group 2 reported significantly less pain than Group 1 (P=0.05). Conclusion: In our study, volumetric capnography during colonoscopy was feasible and effective for monitoring ventilatory parameters and detecting respiratory complications. CO2 insufflation was safe and associated with less pain immediately after colonoscopy.


RESUMO Contexto: A capnografia e a insuflação de gás carbônico (CO2) durante endoscopia digestiva sob sedação são associados à maior segurança e conforto do paciente, respectivamente. A capnografia pode detectar precocemente a apneia e hipoxemia, enquanto a insuflação de CO2 causa menor desconforto periprocedimento. Relatos da aplicação da capnografia volumétrica em colonoscopias são escassos. Objetivo: Avaliar o uso de capnograifa volumétrica durante colonoscopia diagnóstica com insuflação de ar comprimido e CO2. Métodos: Em estudo prospectivo de coorte, foram incluídos um total de 101 pacientes submetidos a colonoscopia diagnóstica sob sedação com monitoração respiratória por meio de capnografia volumétrica. Insuflação com ar comprimido foi usado para distender o lúmen intestinal no Grupo 1 (n=51), enquanto o Grupo 2 (n=50) utilizou CO2 para insuflação. Objetivos primários foram avaliar episódios de hipóxia, hipoventilação alveolar e CO2 expirado (EtCO2). Objetivos secundários foram avaliar o volume alveolar por minuto, consumo de sedativos e a dor pós-colonoscopia por meio da Escala de Dor Modificada de Gloucester. Resultados: O número de episódios de hipóxia (SpO2 <90%) foi semelhante entre os grupos: quatro episódios no Grupo 1 e dois episódios no Grupo 2. A duração da hipóxia foi significativamente maior no Grupo 2 (P=0,02). A hipoventilação alveolar (EtCO2 ≥25% do valor basal) ocorreu mais frequentemente no Grupo 2 quando comparado ao Grupo 1 (27 vs 18 episódios, P=0,05). Em relação ao EtCO2, o Grupo 2 apresentou valores maiores no momento de aferição cecal (28.94±4.68 vs 26.65±6.12 mmHg, P=0,04). Quanto ao volume alveolar por minuto, o Grupo 2 apresentou valores significativamente menores no momento de aferição cecal quando comparado ao Grupo 1 (2027.53±2818.89 vs 970.88±1840.25 L/min, P=0,009). Não houve ocorrência de hipercapnia durante o estudo (EtCO2 >60 mmHg). Não houve diferença em relação ao consumo de sedativos entre os dois grupos. Imediatamente após a colonoscopia, o Grupo 2 apresentou significativamente menos dor que o Grupo 1 (P=0,05). Conclusão: Em nosso estudo, a capnografia volumétrica durante colonoscopia foi factível e eficaz para monitorar parâmetros ventilatórios e detectar complicações respiratórias, e a insuflação com CO2 foi segura e associada a menor dor imediatamente pós-colonoscopia.

13.
Acta Cir Bras ; 32(12): 1036-1044, 2017 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-29319732

RESUMO

PURPOSE: To use blood lactate (BL) as an end-point metabolic marker for the begin resuscitation of volume replacement in experimental hemorrhagic shock. METHODS: Group I (n=7) was not bled (Control). Animals in Group II (n=7) were bled to a MAP of 30mmHg in thirty minutes. Hemodynamic and metabolic data were recorded at Baseline, at 30, 60 and 120 minutes after Baseline. The animals were intubated in spontaneous breathing (FIO2=0.21) with halothane. RESULTS: Group I all survived. In Group II all died; no mortality occurred before a BL<10mM/L. Beyond the end-point all animals exhibited severe acidemia, hyperventilation and clinical signs of shock. Without treatment all animals died within 70.43±24.51 min of hypotension shortly after reaching an average level of BL 17.01±3.20mM/L. CONCLUSIONS: Swine's breathing room air spontaneously in hemorrhagic shock not treated a blood lactate over 10mM/L results fatal. The predictable outcome of this shock model is expected to produce consistent information based on possible different metabolic and hemodynamic patterns as far as the type of fluid and the timing of resuscitation in near fatal hemorrhagic shock.


Assuntos
Hipotensão/metabolismo , Ácido Láctico/sangue , Ressuscitação/métodos , Choque Hemorrágico/metabolismo , Choque Hemorrágico/terapia , Animais , Biomarcadores , Grupos Controle , Modelos Animais de Doenças , Determinação de Ponto Final , Hemodinâmica , Hipotensão/fisiopatologia , Choque Hemorrágico/mortalidade , Choque Hemorrágico/fisiopatologia , Suínos , Fatores de Tempo
14.
Hematol., Transfus. Cell Ther. (Impr.) ; 43(4): 443-452, Oct.-Dec. 2021. tab, graf, ilus
Artigo em Inglês | LILACS | ID: biblio-1350818

RESUMO

ABSTRACT Introduction: Inspiratory muscle training (IMT) has been shown to be an efficient method of improving exercise tolerance and inspiratory and expiratory muscle strength in several diseases. The effects of IMT on patients with sickle cell anemia (SCD) are relatively unknown. Our study aimed to evaluate the effects of IMT on adult SCD patients, regarding respiratory muscle strength (RMS) variables, lung function, exercise tolerance, blood lactation concentration, limitation imposed by dyspnea during daily activities and impact of fatigue on the quality of life. Methods: This was a randomized single-blind study, with an IMT design comprising true load (TG) and sham load (SG) groups. Initial assessment included spirometry, volumetric capnography (VCap) and measurement of RMS by maximal inspiratory and expiratory pressure (PImax and PEmax). The Medical Research Council dyspnea scale and modified fatigue impact scale were also applied and blood lactate concentration was measured before and after the 6-minute walk test. After this initial assessment, the patient used the IMT device at home daily, returning every 6 weeks for RMS reassessment. Both groups used the same device and were unaware of which group they were in. After a period totaling 18 weeks, patients underwent the final evaluation, as initially performed. Results: Twenty-five patients in total participated until the end of the study (median age 42 years). There were no significant differences between TG and SG based on age, sex, body mass index or severity of genotype. At the end of the training, both groups showed a significant increase in PEmax and PImax, improvement in Vcap and in exercise tolerance and dyspnea reduction while performing daily life activities. The same was observed in patients grouped according to disease severity (HbSS and HbSβ0 vs HbSC and HbSβ+), without differences between groups. Conclusion: Home-based inspiratory muscle training benefits outpatients with SCD, including the sham load group. Trial registration:http://www.ensaiosclinicos.gov.br; registration number: RBR-6g8n92.


Assuntos
Humanos , Masculino , Feminino , Adulto , Pessoa de Meia-Idade , Exercícios Respiratórios , Anemia Falciforme , Capacidade Inspiratória , Tolerância ao Exercício , Capnografia , Pressões Respiratórias Máximas
15.
Artigo em Inglês | MEDLINE | ID: mdl-27042039

RESUMO

BACKGROUND: Computed tomography (CT) phenotypic characterization helps in understanding the clinical diversity of chronic obstructive pulmonary disease (COPD) patients, but its clinical relevance and its relationship with functional features are not clarified. Volumetric capnography (VC) uses the principle of gas washout and analyzes the pattern of CO2 elimination as a function of expired volume. The main variables analyzed were end-tidal concentration of carbon dioxide (ETCO2), Slope of phase 2 (Slp2), and Slope of phase 3 (Slp3) of capnogram, the curve which represents the total amount of CO2 eliminated by the lungs during each breath. OBJECTIVE: To investigate, in a group of patients with severe COPD, if the phenotypic analysis by CT could identify different subsets of patients, and if there was an association of CT findings and functional variables. SUBJECTS AND METHODS: Sixty-five patients with COPD Gold III-IV were admitted for clinical evaluation, high-resolution CT, and functional evaluation (spirometry, 6-minute walk test [6MWT], and VC). The presence and profusion of tomography findings were evaluated, and later, the patients were identified as having emphysema (EMP) or airway disease (AWD) phenotype. EMP and AWD groups were compared; tomography findings scores were evaluated versus spirometric, 6MWT, and VC variables. RESULTS: Bronchiectasis was found in 33.8% and peribronchial thickening in 69.2% of the 65 patients. Structural findings of airways had no significant correlation with spirometric variables. Air trapping and EMP were strongly correlated with VC variables, but in opposite directions. There was some overlap between the EMP and AWD groups, but EMP patients had signicantly lower body mass index, worse obstruction, and shorter walked distance on 6MWT. Concerning VC, EMP patients had signicantly lower ETCO2, Slp2 and Slp3. Increases in Slp3 characterize heterogeneous involvement of the distal air spaces, as in AWD. CONCLUSION: Visual assessment and phenotyping of CT in COPD patients is feasible and may help identify functional and clinically different subsets of patients. VC may provide useful information about the heterogeneous involvement of lung structures in COPD.


Assuntos
Doença Pulmonar Obstrutiva Crônica/genética , Doença Pulmonar Obstrutiva Crônica/fisiopatologia , Tomografia Computadorizada por Raios X , Estudos Transversais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Doença Pulmonar Obstrutiva Crônica/diagnóstico por imagem , Testes de Função Respiratória , Estudos Retrospectivos , Índice de Gravidade de Doença
16.
São Paulo med. j ; 139(5): 505-510, May 2021. tab
Artigo em Inglês | LILACS | ID: biblio-1290253

RESUMO

ABSTRACT BACKGROUND: The mechanism of exercise limitation in idiopathic pulmonary arterial hypertension (IPAH) is not fully understood. The role of hemodynamic alterations is well recognized, but mechanical, ventilatory and gasometric factors may also contribute to reduction of exercise capacity in these individuals. OBJECTIVE: To investigate whether there is an association between ventilatory pattern and stress Doppler echocardiography (SDE) variables in IPAH patients. DESIGN AND SETTING: Single-center prospective study conducted in a Brazilian university hospital. METHODS: We included 14 stable IPAH patients and 14 age and sex-matched controls. Volumetric capnography (VCap), spirometry, six-minute walk test and SDE were performed on both the patients and the control subjects. Arterial blood gases were collected only from the patients. The IPAH patients and control subjects were compared with regard to the abovementioned variables. RESULTS: The mean age of the patients was 38.4 years, and 78.6% were women. The patients showed hypocapnia, and in spirometry 42.9% presented forced vital capacity (FVC) below the lower limit of normality. In VCap, IPAH patients had higher respiratory rates (RR) and lower elimination of CO2 in each breath. There was a significant correlation between reduced FVC and the magnitude of increases in tricuspid regurgitation velocity (TRV). In IPAH patients, VCap showed similar tidal volumes and a higher RR, which at least partially explained the hypocapnia. CONCLUSIONS: The patients with IPAH showed hypocapnia, probably related to their higher respiratory rate with preserved tidal volumes; FVC was reduced and this reduction was positively correlated with cardiac output.


Assuntos
Humanos , Feminino , Adulto , Hipertensão Arterial Pulmonar , Estudos Transversais , Estudos Prospectivos , Ecocardiografia sob Estresse , Teste de Esforço , Hipertensão Pulmonar Primária Familiar , Pulmão/diagnóstico por imagem
17.
Einstein (Säo Paulo) ; 18: eAO4805, 2020. tab, graf
Artigo em Inglês | LILACS | ID: biblio-1039729

RESUMO

ABSTRACT Objective To simulate different diameters of endotracheal tubes and to verify the fluid dynamics aspects by means of flow and resistance measurements. Methods Fluid dynamics software was used to calculate mean flow and airway resistance in endotracheal tube with a diameter of 6.0, 7.0, 7.5, 8.0, 9.0 and 10.0mm at normal body temperature and under constant pressure. The same measurements were taken in the fusion of the first 22cm of a 9.0mm endotracheal tube with 10.0mm diameter, and with the end part in 12cm of a 6.0mm endotracheal tube with 7.0mm diameter. Results The fusion of the first 22cm of an endotracheal tube of 10.0mm diameter with the terminal part in 12cm of an endotracheal tube of 6.0mm diameter, preserving the total length of 34cm, generated average flow and airway resistance similar to that of a conventional 7.5mm endotracheal tube. Conclusion This simulation study demonstrates that a single-sized endotracheal tube may facilitate endotracheal intubation without causing increased airway resistance.


RESUMO Objetivo Simular diferentes diâmetros de tubos endotraqueais e verificar os aspectos fluidinâmicos, considerando medições de fluxo e resistência. Métodos Foi utilizado um software de fluidinâmica para calcular o fluxo médio e a resistência das vias aéreas nos tubos endotraqueais com diâmetro de 6,0, 7,0, 7,5, 8,0, 9,0 e 10,0mm, em temperatura corporal normal e pressão constante. As mesmas medidas foram realizadas na fusão dos primeiros 22cm de um tubo endotraqueal de 9,0 e 10,0mm de diâmetro, com a parte terminal em 12cm de um tubo endotraqueal de 6,0 e 7,0mm de diâmetro. Resultados A fusão dos primeiros 22cm de um tubo endotraqueal de diâmetro 10,0 mm com a parte terminal em 12cm de um tubo endotraqueal de 6,0mm de diâmetro, preservando o comprimento total de 34cm, gerou fluxo médio e resistência de vias aéreas semelhantes aos de um tubo endotraqueal convencional de 7,5mm. Conclusão Um tubo endotraqueal de tamanho único pode facilitar a intubação endotraqueal, sem causar aumento de resistência na via aérea.


Assuntos
Simulação por Computador , Desenho de Equipamento/instrumentação , Intubação Intratraqueal/instrumentação , Respiração Artificial/instrumentação , Resistência das Vias Respiratórias , Intubação Intratraqueal/métodos
18.
Braz J Cardiovasc Surg ; 30(6): 668-72, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26934410

RESUMO

OBJECTIVE: Mechanical ventilation is frequently necessary, in which case the use of an endotracheal tube is mandatory. The tube has an inflatable balloon in its distal extremity, whose aim is, among other functions, an efficient arterialization. However, serious injuries in the place of contact of the balloon with the trachea can be frequent. Some studies point out that balloons with permanent pressure may reduce this complication. Nevertheless, air scape, expressed by the inspiratory (IV) and expiratory volume (EV) variation (Δ IV-EV), may occur, possibly leading to hypoxemia. Thus, the goal of this study was to verify the efficiency of a modified endotracheal tube on arterializations compared to the traditional endotracheal tube. METHODS: The modified endotracheal tube presents intermittent insufflation, with three drillings in the internal region of the cuff, allowing for insufflation in the inspiratory phase of the mechanical ventilation. Three animals were used for the control group, with a cuff pressure of 30 cmH2O, and seven pigs had the modified endotracheal tube. Each animal was kept under mechanical ventilation (FIO2=0.21) for 6 hours. Arterial and venous gases were measured every three hours (T0; T3; T6). RESULTS: The gases confirmed the lack of hypoxia between the Groups, with a difference in the ΔIV-EV at T0 (P=0.0486). CONCLUSIONS: In this study, the lack of hypoxia showed the efficiency of the modified endotracheal tube. However, new studies are necessary, particularly in diseased lungs, in order to evaluate the real efficiency of the mentioned device on the pulmonary gas exchange.


Assuntos
Intubação Intratraqueal/instrumentação , Troca Gasosa Pulmonar/fisiologia , Respiração Artificial/instrumentação , Animais , Gasometria , Capnografia , Eficiência , Insuflação/métodos , Intubação Intratraqueal/métodos , Modelos Animais , Suínos
19.
Acta Cir Bras ; 30(8): 561-7, 2015 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-26352336

RESUMO

PURPOSE: To assess the efficacy of an adjustable inspiratory occlusion valve in experimental bronchopleural fistula during mechanical ventilation. METHODS: We studied six mechanically ventilated pigs in a surgically created, reproducible model of bronchopleural fistula managed with mechanical ventilation and water-sealed thoracic drainage. An adjustable inspiratory occlusion valve was placed between the thoracic drain and the endotracheal tube. Hemodynamic data, capnography and blood gases were recorded before and after the creation of the bronchopleural fistula as well as after every adjustment of the inspiratory occlusion valve. RESULTS: When compared with the standard water-sealed drainage treatment, the use of an adjustable inspiratory occlusion valve improved the alveolar tidal volume and reduced bronchopleural air leak (p<0.001), without hemodynamic compromise when compared with conventional water sealed drainage. CONCLUSION: The use of an adjustable inspiratory occlusion valve improved the alveolar tidal volume, reduced alveolar leak, in an experimental reproducible model of bronchopleural fistula, without causing any hemodynamic derangements when compared with conventional water sealed drainage.


Assuntos
Fístula Brônquica/terapia , Drenagem/instrumentação , Doenças Pleurais/terapia , Oclusão Terapêutica/instrumentação , Ventiladores Mecânicos , Animais , Pressão Arterial/fisiologia , Gasometria , Drenagem/métodos , Hemodinâmica/fisiologia , Intubação Intratraqueal/instrumentação , Ilustração Médica , Reprodutibilidade dos Testes , Respiração Artificial/métodos , Testes de Função Respiratória/métodos , Suínos , Oclusão Terapêutica/métodos , Resultado do Tratamento
20.
Rev Bras Cir Cardiovasc ; 30(1): 24-32, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-25859864

RESUMO

OBJECTIVE: A retrospective cohort study was preformed aiming to verify the presence of transient dysfunction of gas exchange in the postoperative period of cardiac surgery and determine if this disorder is linked to cardiorespiratory events. METHODS: We included 942 consecutive patients undergoing cardiac surgery and cardiac procedures who were referred to the Intensive Care Unit between June 2007 and November 2011. RESULTS: Fifteen patients had acute respiratory distress syndrome (2%), 199 (27.75%) had mild transient dysfunction of gas exchange, 402 (56.1%) had moderate transient dysfunction of gas exchange, and 39 (5.4%) had severe transient dysfunction of gas exchange. Hypertension and cardiogenic shock were associated with the emergence of moderate transient dysfunction of gas exchange postoperatively (P=0.02 and P=0.019, respectively) and were risk factors for this dysfunction (P=0.0023 and P=0.0017, respectively). Diabetes mellitus was also a risk factor for transient dysfunction of gas exchange (P=0.03). Pneumonia was present in 8.9% of cases and correlated with the presence of moderate transient dysfunction of gas exchange (P=0.001). Severe transient dysfunction of gas exchange was associated with patients who had renal replacement therapy (P=0.0005), hemotherapy (P=0.0001), enteral nutrition (P=0.0012), or cardiac arrhythmia (P=0.0451). CONCLUSION: Preoperative hypertension and cardiogenic shock were associated with the occurrence of postoperative transient dysfunction of gas exchange. The preoperative risk factors included hypertension, cardiogenic shock, and diabetes. Postoperatively, pneumonia, ventilator-associated pneumonia, renal replacement therapy, hemotherapy, and cardiac arrhythmia were associated with the appearance of some degree of transient dysfunction of gas exchange, which was a risk factor for reintubation, pneumonia, ventilator-associated pneumonia, and renal replacement therapy in the postoperative period of cardiac surgery and cardiac procedures.


Assuntos
Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/fisiopatologia , Troca Gasosa Pulmonar/fisiologia , Doenças Respiratórias/etiologia , Doenças Respiratórias/fisiopatologia , Adulto , Idoso , Complicações do Diabetes , Métodos Epidemiológicos , Feminino , Humanos , Hipertensão/complicações , Unidades de Terapia Intensiva , Tempo de Internação , Masculino , Pessoa de Meia-Idade , Síndrome do Desconforto Respiratório/etiologia , Índice de Gravidade de Doença , Choque Cardiogênico/complicações , Fatores de Tempo
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa