Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 14 de 14
Filtrar
1.
Clin Transplant ; 37(6): e14982, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-36988473

RESUMO

BACKGROUND: The frequency and significance of cytomegalovirus (CMV) infection in seropositive (R+) heart transplant recipients (HTR) is unclear, with preventative recommendations mostly extrapolated from other groups. We evaluated the incidence and severity of CMV infection in R+ HTR, to identify risk factors and describe outcomes. METHODS: R+ HTR from 2010 to 2019 were included. Antiviral prophylaxis was not routinely used, with clinically guided monitoring the local standard of care. The primary outcome was CMV infection within one-year post-transplant; secondary outcomes included other herpesvirus infections and mortality. RESULTS: CMV infection occurred in 27/155 (17%) R+ HTR. Patients with CMV had a longer hospitalization (27 vs. 20 days, unadjusted HR 1.02, 95% CI 1.00-1.02, p = .01), higher rate of intensive care readmission (26% vs. 9%, unadjusted HR 3.46, 1.46-8.20, p = .005), and increased mortality (33% vs. 8%, unadjusted HR 10.60, 4.52-24.88, p < .001). The association between CMV and death persisted after adjusting for multiple confounders (HR 24.19, 95% CI 7.47-78.30, p < .001). Valganciclovir prophylaxis was used in 35/155 (23%) and was protective against CMV (infection rate 4% vs. 27%, adjusted HR .07, .01-.72, p = .025), even though those receiving it were more likely to have received thymoglobulin (adjusted OR 10.5, 95% CI 2.01-55.0, p = .005). CONCLUSIONS: CMV infection is common in R+ HTR and is associated with a high burden of disease and increased mortality. Patients who received valganciclovir prophylaxis were less likely to develop CMV infection, despite being at higher risk. These findings support the routine use of antiviral prophylaxis following heart transplantation in all CMV R+ patients.


Assuntos
Infecções por Citomegalovirus , Transplante de Coração , Humanos , Valganciclovir/uso terapêutico , Antivirais/uso terapêutico , Ganciclovir/uso terapêutico , Incidência , Infecções por Citomegalovirus/epidemiologia , Infecções por Citomegalovirus/etiologia , Infecções por Citomegalovirus/prevenção & controle , Transplante de Coração/efeitos adversos , Transplantados , Estudos Retrospectivos
2.
Intern Med J ; 53(5): 830-834, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-37134235

RESUMO

This audit collates data on alcohol-related gastrointestinal (GI) admissions at Monash Health, Victoria, during the prolonged, coronavirus disease 2019 (COVID-19)-related lockdown July to October 2020 compared with the same periods in 2019 and 2021. We found a 58% increase in admissions in 2020 and a 16% increase in 2021, which also increased disproportionately to overall health service emergency presentations. Self-reported alcohol consumption increased by 2.5-fold and was greatest in 2020. Clinical severity was unchanged and cirrhosis was the only factor associated with severe disease. This study suggests an association between the pandemic-related lockdown, alcohol consumption and alcohol-related GI hospitalisation. Our study provides support for resourcing and adapting alcohol and other drug services during and beyond the COVID-19 lockdown.


Assuntos
COVID-19 , Pancreatite , Humanos , Controle de Doenças Transmissíveis , Hemorragia Gastrointestinal , Etanol , Consumo de Bebidas Alcoólicas , Hospitalização , Fígado
3.
AAPS PharmSciTech ; 22(7): 225, 2021 Aug 19.
Artigo em Inglês | MEDLINE | ID: mdl-34410557

RESUMO

Batch-to-batch pharmacokinetic (PK) variability of orally inhaled drug products has been documented and can render single-batch PK bioequivalence (BE) studies unreliable; results from one batch may not be consistent with a repeated study using a different batch, yet the goal of PK BE is to deliver a product comparison that is interpretable beyond the specific batches used in the study. We characterized four multiple-batch PK BE approaches to improve outcome reliability without increasing the number of clinical study participants. Three approaches include multiple batches directly in the PK BE study with batch identity either excluded from the statistical model ("Superbatch") or included as a fixed or random effect ("Fixed Batch Effect," "Random Batch Effect"). A fourth approach uses a bio-predictive in vitro test to screen candidate batches, bringing the median batch of each product into the PK BE study ("Targeted Batch"). Three of these approaches (Fixed Batch Effect, Superbatch, Targeted Batch) continue the single-batch PK BE convention in which uncertainty in the Test/Reference ratio estimate due to batch sampling is omitted from the Test/Reference confidence interval. All three of these approaches provided higher power to correctly identify true bioequivalence than the standard single-batch approach with no increase in clinical burden. False equivalence (type I) error was inflated above the expected 5% level, but multiple batches controlled type I error better than a single batch. The Random Batch Effect approach restored 5% type I error, but had low power for small (e.g., <8) batch sample sizes using standard [0.8000, 1.2500] bioequivalence limits.


Assuntos
Modelos Estatísticos , Preparações Farmacêuticas , Equivalência Terapêutica , Humanos , Reprodutibilidade dos Testes
4.
AAPS PharmSciTech ; 21(5): 147, 2020 May 20.
Artigo em Inglês | MEDLINE | ID: mdl-32435854

RESUMO

The objective of this work was to study the performance of the modified chi-square ratio statistic (mCSRS test) proposed for cascade impactor (CI) profile equivalence testing. The test (T) and reference (R) CI profile datasets were generated from different typical CI profile patterns either with or without inter-site correlation (ISC) through Monte Carlo simulations. The mCSRS test pass rate outcome employing previously published critical values was compared with that of critical values derived from different types of datasets. The influence of number of bootstrap iterations (B) on the consistency of the outcome was assessed within the range of 10-10,000 iterations. Power curves were constructed to study the effect of differences in T and R mean stage deposition, T/R variance ratios, differences between T and R profiles in high/low deposition sites, and sample size on the performance of the mCSRS test. The derived critical values exhibited trends based on R product variability: M1 rank-ordered without ISC (at low variability) and the previously published M8 critical values (at high variability) resulted in lowest pass rate outcomes. The precision of the outcome did not increase considerably beyond B = 2000 (default). The probability of showing equivalence between T and R CI profiles increased with (1) a decrease in mean deposition differences, (2) a decrease in T product variability, and (3) an increase in sample size. The mCSRS outcome is less sensitive to low deposition sites that are prone to analytical variability. In conclusion, the mCSRS test is a sensitive and robust method under most conditions.


Assuntos
Distribuição de Qui-Quadrado , Método de Monte Carlo , Equivalência Terapêutica , Humanos , Probabilidade
5.
AAPS PharmSciTech ; 20(7): 296, 2019 Aug 23.
Artigo em Inglês | MEDLINE | ID: mdl-31444601

RESUMO

This article extends previous work studying performance characteristics of the population bioequivalence (PBE) statistical test recommended by the US Food and Drug Administration (FDA) for orally inhaled and nasal drug products. Based on analysis of a metered dose inhaler database for impactor sized mass, a simulation study was designed to compare performance of the recommended PBE approach with several modified or alternative approaches. These included an extended PBE that separately modeled within-batch (can) and between-batch (batch) variability and average bioequivalence (ABE) tests that modeled with or without between-batch variability and with or without log-transformation. This work showed that separately modeling within- and between-batch variability while increasing the number of sampled batches addressed previously identified issues of the PBE approach when between-batch variability was present, namely, (a) increased risk for falsely concluding equivalence and (b) low probability of correctly concluding equivalence. The same modifications were also required of the ABE to achieve expected performance. However, these modifications did not successfully address the issue of equivalence conclusions that depended on the direction of product mean differences (asymmetric performance). This work highlights the importance of understanding decision-making error rates in developing regulatory recommendations to standardize bioequivalence outcomes across products.


Assuntos
Inaladores Dosimetrados/estatística & dados numéricos , Preparações Farmacêuticas/administração & dosagem , Equivalência Terapêutica , United States Food and Drug Administration/estatística & dados numéricos , Administração por Inalação , Bases de Dados Factuais/estatística & dados numéricos , Humanos , Nebulizadores e Vaporizadores/estatística & dados numéricos , Estados Unidos
6.
AAPS PharmSciTech ; 20(6): 249, 2019 Jul 08.
Artigo em Inglês | MEDLINE | ID: mdl-31286316

RESUMO

The performances of three statistical approaches for assessing in vitro equivalence was evaluated with a set of 55 scenarios of realistic test (T) and reference (R) cascade impactor (CI) profiles (originally employed by the Product Quality Research Institute to evaluate the chi-square ratio statistic: CSRS) by comparing the outcomes against experts' opinion (surrogate for the truth). The three methods were (A) a stepwise aerodynamic particle size distribution (APSD) equivalence test integrating population bioequivalence (PBE) testing of impactor-sized mass (ISM) with the CSRS (PBE-CSRS approach), previously suggested by the USFDA; (B) the combination of PBE testing of single actuation content and ISM with the newly suggested modified CSRS (PBE-mCSRS approach), a method employing reference variance scaling; and (C) EMA's average bioequivalence (ABE approach). Based on Monte-Carlo simulations, both PBE-CSRS and ABE approaches resulted in high misclassification rates, the former with highest false-pass rate and the latter with highest false-fail rate at both ≥ 50% and ≥ 80% classification threshold values (the % of simulations or experts necessary to judge a given scenario as equivalent). Based on DeLong's tests, the PBE-mCSRS approach showed significantly better overall agreement with experts' opinion compared to the other approaches. Comparison of CSRS with mCSRS (both without PBE) suggested that the more discriminatory characteristics of the mCSRS method is based on the integration of variance scaling into the mCSRS method. Contrary to the ABE approach, the application of PBE-mCSRS approach for assessing APSD profiles of three dry powder inhaler (DPI) formulations supported the pharmacokinetic bioequivalence assessment of these formulations.


Assuntos
Inaladores de Pó Seco , Equivalência Terapêutica , Administração por Inalação , Distribuição de Qui-Quadrado , Humanos , Método de Monte Carlo , Tamanho da Partícula , Estados Unidos
7.
AAPS PharmSciTech ; 19(3): 1410-1425, 2018 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-29435904

RESUMO

This article reports performance characteristics of the population bioequivalence (PBE) statistical test recommended by the US Food and Drug Administration (FDA) for orally inhaled products. A PBE Working Group of the International Pharmaceutical Aerosol Consortium on Regulation and Science (IPAC-RS) assembled and considered a database comprising delivered dose measurements from 856 individual batches across 20 metered dose inhaler products submitted by industry. A review of the industry dataset identified variability between batches and a systematic lifestage effect that was not included in the FDA-prescribed model for PBE. A simulation study was designed to understand PBE performance when factors identified in the industry database were present. Neglecting between-batch variability in the PBE model inflated errors in the equivalence conclusion: (i) The probability of incorrectly concluding equivalence (type I error) often exceeded 15% for non-zero between-batch variability, and (ii) the probability of incorrectly rejecting equivalence (type II error) for identical products approached 20% when product and between-batch variabilities were high. Neglecting a systematic through-life increase in the PBE model did not substantially impact PBE performance for the magnitude of lifestage effect considered. Extreme values were present in 80% of the industry products considered, with low-dose extremes having a larger impact on equivalence conclusions. The dataset did not support the need for log-transformation prior to analysis, as requested by FDA. Log-transformation resulted in equivalence conclusions that depended on the direction of product mean differences. These results highlight a need for further refinement of in vitro equivalence methodology.


Assuntos
Inaladores Dosimetrados , Modelos Estatísticos , Bases de Dados Factuais , Equivalência Terapêutica , Estados Unidos , United States Food and Drug Administration
8.
AAPS PharmSciTech ; 8(1): 5, 2007 Jan 19.
Artigo em Inglês | MEDLINE | ID: mdl-17408228

RESUMO

The purpose of this article is to present the thought process, methods, and interim results of a PQRI Working Group, which was charged with evaluating the chi-square ratio test as a potential method for determining in vitro equivalence of aerodynamic particle size distribution (APSD) profiles obtained from cascade impactor measurements. Because this test was designed with the intention of being used as a tool in regulatory review of drug applications, the capability of the test to detect differences in APSD profiles correctly and consistently was evaluated in a systematic way across a designed space of possible profiles. To establish a "base line," properties of the test in the simplest case of pairs of identical profiles were studied. Next, the test's performance was studied with pairs of profiles, where some difference was simulated in a systematic way on a single deposition site using realistic product profiles. The results obtained in these studies, which are presented in detail here, suggest that the chi-square ratio test in itself is not sufficient to determine equivalence of particle size distributions. This article, therefore, introduces the proposal to combine the chi-square ratio test with a test for impactor-sized mass based on Population Bioequivalence and describes methods for evaluating discrimination capabilities of the combined test. The approaches and results described in this article elucidate some of the capabilities and limitations of the original chi-square ratio test and provide rationale for development of additional tests capable of comparing APSD profiles of pharmaceutical aerosols.


Assuntos
Aerossóis/química , Interpretação Estatística de Dados , Avaliação Pré-Clínica de Medicamentos/normas , Teste de Materiais/métodos , Teste de Materiais/normas , Garantia da Qualidade dos Cuidados de Saúde/normas , Equivalência Terapêutica , Aprovação de Drogas/métodos , Avaliação Pré-Clínica de Medicamentos/métodos , Guias como Assunto , Tamanho da Partícula , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Estados Unidos , United States Food and Drug Administration
9.
AAPS PharmSciTech ; 8(1): 4, 2007 Jan 19.
Artigo em Inglês | MEDLINE | ID: mdl-17408227

RESUMO

The purpose of this article is 2-fold: (1) to document in the public domain the considerations that led to the development of a regulatory statistical test for comparison of aerodynamic particle size distribution (APSD) of aerosolized drug formulations, which was proposed in a US Food and Drug Administration (FDA) draft guidance for industry; and (2) to explain the background and process for evaluation of that test through a working group involving scientists from the FDA, industry, academia, and the US Pharmacopeia, under the umbrella of the Product Quality Research Institute (PQRI). The article and the referenced additional statistical information posted on the PQRI Web site explain the reasoning and methods used in the development of the APSD test, which is one of the key tests required for demonstrating in vitro equivalence of orally inhaled and nasal aerosol drug products. The article also describes the process by which stakeholders with different perspectives have worked collaboratively to evaluate properties of the test by drawing on statistical models, historical and practical information, and scientific reasoning. Overall, this article provides background information to accompany the companion article's discussion of the study's methods and results.


Assuntos
Aerossóis/química , Interpretação Estatística de Dados , Avaliação Pré-Clínica de Medicamentos/normas , Guias como Assunto , Teste de Materiais/métodos , Teste de Materiais/normas , Garantia da Qualidade dos Cuidados de Saúde/normas , Aprovação de Drogas/métodos , Avaliação Pré-Clínica de Medicamentos/métodos , Tamanho da Partícula , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Estados Unidos , United States Food and Drug Administration
10.
AAPS PharmSciTech ; 8(4): E90, 2007 Nov 02.
Artigo em Inglês | MEDLINE | ID: mdl-18181550

RESUMO

The purpose of this article is to report final results of the evaluation of a chi-square ratio test proposed by the US Food and Drug Administration (FDA) for demonstrating equivalence of aerodynamic particle size distribution (APSD) profiles of nasal and orally inhaled drug products. A working group of the Product Quality Research Institute previously published results demonstrating some limitations of the proposed test. In an effort to overcome the test's limited discrimination, the group proposed a supplemental test, a population bioequivalence (PBE) test for impactor-sized mass (ISM). In this final report the group compares the chi-square ratio test to the ISM-PBE test and to the combination of both tests. The basis for comparison is a set of 55 realistic scenarios of cascade impactor data, which were evaluated for equivalence by the statistical tests and independently by the group members. In many instances, the combined application of these 2 tests appeared to increase the discriminating ability of the statistical procedure compared with the chi-square ratio test alone. In certain situations the chi-square ratio test alone was sufficient to determine equivalence of APSD profiles, while in other situations neither of the tests alone nor their combination was adequate. This report describes all of these scenarios and results. In the end, the group did not recommend a statistical test for APSD profile equivalence. The group did not investigate other in vitro tests, in vivo issues, or other statistical tests for APSD profile comparisons. The studied tests are not intended for routine quality control of APSD.


Assuntos
Aerossóis , Nebulizadores e Vaporizadores , Preparações Farmacêuticas/química , Tecnologia Farmacêutica/instrumentação , Academias e Institutos , Administração por Inalação , Administração Intranasal , Distribuição de Qui-Quadrado , Interpretação Estatística de Dados , Desenho de Equipamento , Guias como Assunto , Tamanho da Partícula , Preparações Farmacêuticas/administração & dosagem , Controle de Qualidade , Reprodutibilidade dos Testes , Tecnologia Farmacêutica/métodos , Tecnologia Farmacêutica/normas , Equivalência Terapêutica , Estados Unidos , United States Food and Drug Administration
11.
AAPS J ; 17(4): 837-52, 2015 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-25940082

RESUMO

This article is part of a series of reports from the "Orlando Inhalation Conference-Approaches in International Regulation" which was held in March 2014, and coorganized by the University of Florida and the International Pharmaceutical Aerosol Consortium on Regulation and Science (IPAC-RS). The goal of the conference was to foster the exchange of ideas and knowledge across the global scientific and regulatory community in order to identify and help move towards strategies for internationally harmonized, science-based regulatory approaches for the development and marketing approval of inhalation medicines, including innovator and second entry products. This article provides an integrated perspective of case studies and discussion related to in vitro testing of orally inhaled products, including in vitro-in vivo correlations and requirements for in vitro data and statistical analysis that support quality or bioequivalence for regulatory applications.


Assuntos
Aprovação de Drogas , Desenho de Fármacos , Preparações Farmacêuticas/administração & dosagem , Administração por Inalação , Aerossóis , Humanos , Equivalência Terapêutica
12.
J Altern Complement Med ; 21(5): 288-93, 2015 May.
Artigo em Inglês | MEDLINE | ID: mdl-25893960

RESUMO

OBJECTIVES: Elevated blood cholesterol levels are a major risk factor for coronary artery disease, the leading cause of death worldwide. Probiotics have been investigated as potential cholesterol-lowering therapies, but no previous studies have assessed the effect of the probiotic yeast Saccharomyces boulardii on cholesterol levels in human volunteers. The objective of this study was to examine the effect of S. boulardii on serum cholesterol and lipoprotein particles in hypercholesterolemic adults. DESIGN: This study was a single-arm, open-label pilot study. SUBJECTS: Twelve hypercholesterolemic participants were recruited into the study; one dropped out. INTERVENTION: Participants took 5.6×10(10) colony forming unit (CFU) encapsulated S. boulardii (Saccharomyces cerevisiae var. boulardii CNCM I-1079) twice daily for an 8-week period. OUTCOME MEASURES: Fasting concentrations of cholesterol (total cholesterol, low-density lipoprotein-cholesterol [LDL-C], high-density lipoprotein-cholesterol [HDL-C], and triglycerides), lipoprotein particles (very-low-density lipoprotein-particle [VLDL-P], remnant lipoprotein particle [RLP-P], total LDL-P, LDL III-P, LDL IV-P, total HDL-P, and HDL 2b-P), and additional cardiovascular biomarkers (apo B-100, lipoprotein [a], high-sensitivity C-reactive protein, homocysteine, fibrinogen, and insulin) were measured at baseline, after 4 weeks, and after 8 weeks. RESULTS: Remnant lipoprotein particles decreased by 15.5% (p=0.03) over the 8-week period. The remaining outcome measures were not significantly altered. CONCLUSIONS: In this pilot study, 8 weeks of daily supplementation with S. boulardii lowered remnant lipoprotein, a predictive biomarker and potential therapeutic target in the treatment and prevention of coronary artery disease.


Assuntos
Colesterol/sangue , Hipercolesterolemia/sangue , Hipercolesterolemia/dietoterapia , Probióticos/administração & dosagem , Saccharomyces , Adulto , Idoso , Biomarcadores/sangue , Índice de Massa Corporal , Feminino , Humanos , Estilo de Vida , Lipoproteínas/sangue , Masculino , Pessoa de Meia-Idade , Projetos Piloto , Adulto Jovem
13.
J Sports Sci Med ; 2(3): 117-22, 2003 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-24627664

RESUMO

The influence of gender on aerobic energy expenditure (EE) during weight training has not been systematically researched. We determined the absolute and relative EE during the performance of two weight training programs of different intensities, durations and total work in males and females. Eight male and seven female recreational weight trainers (20-29 y) completed two randomly ordered weight training sessions involving 2 sets of 8 standard upper and lower body lifts at a set cadence separated by 45 seconds rest between sets and lifts (48 hrs apart). Heavy (H) at 100% 8 Repetition Maximum (8RM), 8 reps, ~19 min duration and light (L) at 85% 8RM, 15 reps, ~23 min duration. VO2 was determined continuously throughout the training sessions. Lean body mass (LBM) was estimated from skin fold measures and body weight. Energy expenditure was estimated from breath-by-breath metabolic measurements using portable metabolic assessment equipment (Cosmed K4b(2)). Absolute EE (total kJ) and rate of energy expenditure per minute (kJ per min) were not significantly different between H and L intensities and male and female subjects. The rate of EE averaged between approximately 10-12 kJ per min. However, relative EE (J per kg LBM per min per unit work) were significantly higher (p < 0.02) for females compared to males in both H: (26.46±8.06 females vs 14.36±3.02 males) and L: (19.91±4.28 females vs. 9.83±3.28 males), intensities. It was concluded that females rely on a greater relative aerobic EE than males when performing recreational type weight lifting programs.

14.
AAPS J ; 16(1): 89-100, 2014 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-24249218

RESUMO

Regulatory agencies, industry, and academia have acknowledged that in vitro assessments serve a role in establishing bioequivalence for second-entry drug product approvals as well as innovator post-approval drug product changes. For orally inhaled respiratory products (OIPs), the issues of correctly analyzing in vitro data and interpreting the results within the broader context of therapeutic equivalence have garnered significant attention. One of the recommended statistical tests for in vitro data is the population bioequivalence method (PBE). The current literature for assessing the PBE statistical approach for in vitro data assumes a log normal distribution. This paper focuses on an assessment of that assumption for in vitro delivered dose. Concepts in development of a statistical model are presented. The PBE criterion and hypotheses are written for the case when data follows a normal distribution, rather than log normal. Results of a simulation study are reported, characterizing the performance of the PBE approach when data are expected to be normally distributed, rather than log normal. In these cases, decisions using the PBE approach are not consistent for the same absolute mean difference that the test product is from the reference product. A conclusion of inequivalency will occur more often if the test product dose is lower than the reference product for the same deviation from target. These features suggest that more research is needed for statistical equivalency approaches for in vitro data.


Assuntos
Administração por Inalação , Modelos Estatísticos , Equivalência Terapêutica , Simulação por Computador , Cálculos da Dosagem de Medicamento , Humanos
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa