Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
JACC Cardiovasc Interv ; 14(17): 1917-1923, 2021 09 13.
Artigo em Inglês | MEDLINE | ID: mdl-34391704

RESUMO

OBJECTIVES: The aim of this study was to evaluate the 1-year safety and efficacy of a dual-layered stent (DLS) for carotid artery stenting (CAS) in a multicenter registry. BACKGROUND: DLS have been proved to be safe and efficient during short-term follow-up. Recent data have raised the concern that the benefit of CAS performed with using a DLS may be hampered by a higher restenosis rate at 1 year. METHODS: From January 2017 to June 2019, a physician-initiated, prospective, multispecialty registry enrolled 733 consecutive patients undergoing CAS using the CGuard embolic prevention system at 20 centers. The primary endpoint was the occurrence of death and stroke at 1 year. Secondary endpoints were 1-year rates of transient ischemic attack, acute myocardial infarction, internal carotid artery (ICA) restenosis, in-stent thrombosis, and external carotid artery occlusion. RESULTS: At 1 year, follow-up was available in 726 patients (99.04%). Beyond 30 days postprocedure, 1 minor stroke (0.13%), four transient ischemic attacks (0.55%), 2 fatal acute myocardial infarctions (0.27%), and 6 noncardiac deaths (1.10%) occurred. On duplex ultrasound examination, ICA restenosis was found in 6 patients (0.82%): 2 total occlusions and 4 in-stent restenoses. No predictors of target ICA restenosis and/or occlusion could be detected, and dual-antiplatelet therapy duration (90 days vs 30 days) was not found to be related to major adverse cardiovascular event or restenosis occurrence. CONCLUSIONS: This real-world registry suggests that DLS use in clinical practice is safe and associated with minimal occurrence of adverse neurologic events up to 12-month follow-up.


Assuntos
Estenose das Carótidas , Artéria Carótida Interna , Estenose das Carótidas/diagnóstico por imagem , Estenose das Carótidas/terapia , Humanos , Estudos Prospectivos , Stents , Resultado do Tratamento
2.
JACC Cardiovasc Interv ; 13(18): 2170-2177, 2020 09 28.
Artigo em Inglês | MEDLINE | ID: mdl-32861633

RESUMO

OBJECTIVES: This study sought to evaluate 30-day safety and efficacy of dual-layer mesh-covered carotid stent systems for carotid artery stenting (CAS) in the clinical practice. BACKGROUND: When compared with carotid endarterectomy, CAS has been associated with a higher rate of post procedural neurologic events; these could be related to plaque's debris prolapsing through stent's mesh. Consequently, the need for increased plaque coverage has resulted in the development of dual-layer mesh-covered carotid stent systems. METHODS: From January 2017 to June 2019, a physician-initiated, prospective, multispecialty registry enrolled 733 consecutive patients undergoing CAS using the CGuard embolic prevention system in 20 centers. The primary endpoint was stroke up to 30 days; secondary endpoints were technical and procedural success; external carotid artery occlusion; and in-hospital and 30-day transient ischemic attack (TIA), acute myocardial infarction (AMI), and death rates. RESULTS: Symptoms were present in 131 (17.87%) patients. An embolic protection device was used in 731 (99.72%) patients. Procedural success was 100%, technical success was obtained in all but 1 (99.86%) patient, who died in hospital due to a hemorrhagic stroke. Six TIAs, 2 minor strokes, and 1 AMI occurred during in-hospital stay, and external carotid artery occlusion was evident in 8 (1.09%) patients. Between hospital discharge and 30-day follow-up, 2 TIAs, 1 minor stroke, and 3 AMIs occurred. Therefore, the cumulative stroke rate was 0.54%. CONCLUSIONS: This real-world registry suggests that use of CGuard embolic prevention system in clinical practice is safe and associated with a minimal occurrence of adverse neurological events up to 30-day follow-up.


Assuntos
Estenose das Carótidas , Acidente Vascular Cerebral , Humanos , Estudos Prospectivos , Stents , Fatores de Tempo , Resultado do Tratamento
3.
EJVES Short Rep ; 41: 8-9, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30426095

RESUMO

INTRODUCTION: Percutaneous endovascular abdominal aortic aneurysm repair (PEVAR) using the Perclose ProGlide suture mediated closure device is currently performed on a global scale. A safe, effective, and cheap technique for achieving haemostasis during PEVAR is described that allows the reversible downsizing of the arteriotomy, without using any other devices. TECHNIQUE: The procedure consists of pulling the blue thread of the pre-implanted ProGlide, advancing the knot close to the arterial wall by pushing it with the dilator of a small introducer sheath, and maintaining the system under tension by grasping the end of the blue thread with a haemostat until bleeding control is achieved. DISCUSSION: Seventeen PEVAR femoral access downsizing procedures have been performed between February and June 2018 and no complications were observed. The technique could be useful in everyday practice and has now become the author's standard practice.

4.
J Vasc Surg Cases Innov Tech ; 3(1): 30-34, 2017 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-29349370

RESUMO

Isolated and spontaneous superior mesenteric artery dissection is a rare cause of acute abdominal pain. Whereas there is widespread consensus on conservative treatment of asymptomatic forms, revascularization would seem indicated in symptomatic complicated cases. A 73-year-old man presented with worsening epigastric pain. A computed tomography scan revealed an isolated and spontaneous superior mesenteric artery dissection with aneurysmal evolution of the false lumen, involving multiple side branches. The postdissection aneurysm was treated by endovascular exclusion with flow-diverting stents. The abdominal pain was completely relieved, and the patient remained asymptomatic at follow-up.

SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa