Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
1.
Clin Infect Dis ; 78(5): 1313-1320, 2024 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-38306491

RESUMO

BACKGROUND: Sputum-based testing is a barrier to increasing access to molecular diagnostics for tuberculosis (TB). Many people with TB are unable to produce sputum, and sputum processing increases assay complexity and cost. Tongue swabs are emerging as an alternative to sputum, but performance limits are uncertain. METHODS: From June 2022 to July 2023, we enrolled 397 consecutive adults with cough >2 weeks at 2 health centers in Kampala, Uganda. We collected demographic and clinical information, sputum for TB testing (Xpert MTB/RIF Ultra and 2 liquid cultures), and tongue swabs for same-day quantitative polymerase chain reaction (qPCR) testing. We evaluated tongue swab qPCR diagnostic accuracy versus sputum TB test results, quantified TB targets per swab, assessed the impact of serial swabbing, and compared 2 swab types (Copan FLOQSWAB and Steripack spun polyester). RESULTS: Among 397 participants, 43.1% were female, median age was 33 years, 23.5% were diagnosed with human immunodeficiency virus, and 32.0% had confirmed TB. Sputum Xpert Ultra and tongue swab qPCR results were concordant for 98.2% (95% confidence interval [CI]: 96.2-99.1) of participants. Tongue swab qPCR sensitivity was 92.6% (95% CI: 86.5 to 96.0) and specificity was 99.1% (95% CI: 96.9 to 99.8) versus microbiological reference standard. A single tongue swab recovered a 7-log range of TB copies, with a decreasing recovery trend among 4 serial swabs. Swab types performed equivalently. CONCLUSIONS: Tongue swabs are a promising alternative to sputum for molecular diagnosis of TB, with sensitivity approaching sputum-based molecular tests. Our results provide valuable insights for developing successful tongue swab-based TB diagnostics.


Assuntos
Mycobacterium tuberculosis , Reação em Cadeia da Polimerase em Tempo Real , Sensibilidade e Especificidade , Manejo de Espécimes , Escarro , Língua , Humanos , Feminino , Escarro/microbiologia , Masculino , Uganda , Adulto , Língua/microbiologia , Manejo de Espécimes/métodos , Mycobacterium tuberculosis/genética , Mycobacterium tuberculosis/isolamento & purificação , Reação em Cadeia da Polimerase em Tempo Real/métodos , Técnicas de Diagnóstico Molecular/métodos , Técnicas de Diagnóstico Molecular/normas , Tuberculose/diagnóstico , Tuberculose/microbiologia , Pessoa de Meia-Idade , Adulto Jovem , Tuberculose Pulmonar/diagnóstico , Tuberculose Pulmonar/microbiologia
2.
Lancet Glob Health ; 12(2): e226-e234, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38245113

RESUMO

BACKGROUND: Non-sputum-based triage tests for tuberculosis are a priority for ending tuberculosis. We aimed to evaluate the diagnostic accuracy of the late-prototype Xpert MTB Host Response (Xpert HR) blood-based assay. METHODS: We conducted a prospective diagnostic accuracy study among outpatients with presumed tuberculosis in outpatient clinics in Viet Nam, India, the Philippines, Uganda, and South Africa. Eligible participants were aged 18 years or older and reported cough lasting at least 2 weeks. We excluded those receiving tuberculosis treatment in the preceding 12 months and those who were unwilling to consent. Xpert HR was performed on capillary or venous blood. Reference standard testing included sputum Xpert MTB/RIF Ultra and mycobacterial culture. We performed receiver operating characteristic (ROC) analysis to identify the optimal cutoff value for the Xpert HR to achieve the target sensitivity of 90% or more while maximising specificity, then calculated diagnostic accuracy using this cutoff value. This study was prospectively registered with ClinicalTrials.gov, NCT04923958. FINDINGS: Between July 13, 2021, and Aug 15, 2022, 2046 adults with at least 2 weeks of cough were identified, of whom 1499 adults (686 [45·8%] females and 813 [54·2%] males) had valid Xpert HR and reference standard results. 329 (21·9%) had microbiologically confirmed tuberculosis. Xpert HR had an area under the ROC curve of 0·89 (95% CI 0·86-0·91). The optimal cutoff value was less than or equal to -1·25, giving a sensitivity of 90·3% (95% CI 86·5-93·3; 297 of 329) and a specificity of 62·6% (95% CI 59·7-65·3; 732 of 1170). Sensitivity was similar across countries, by sex, and by subgroups, although specificity was lower in people living with HIV (45·1%, 95% CI 37·8-52·6) than in those not living with HIV (65·9%, 62·8-68·8; difference of 20·8%, 95% CI 13·0-28·6; p<0·0001). Xpert HR had high negative predictive value (95·8%, 95% CI 94·1-97·1), but positive predictive value was only 40·1% (95% CI 36·8-44·1). Using the Xpert HR as a triage test would have reduced confirmatory sputum testing by 57·3% (95% CI 54·2-60·4). INTERPRETATION: Xpert HR did not meet WHO minimum specificity targets for a non-sputum-based triage test for pulmonary tuberculosis. Despite promise as a rule-out test that could reduce confirmatory sputum testing, further cost-effectiveness modelling and data on acceptability and usability are needed to inform policy recommendations. FUNDING: National Institute of Allergy and Infectious Diseases of the US National Institutes of Health. TRANSLATIONS: For the Vietnamese and Tagalog translations of the abstract see Supplementary Materials section.


Assuntos
Soropositividade para HIV , Mycobacterium tuberculosis , Tuberculose Pulmonar , Adulto , Feminino , Humanos , Masculino , Tosse , Índia , Filipinas , Estudos Prospectivos , Sensibilidade e Especificidade , África do Sul , Escarro/microbiologia , Triagem , Tuberculose Pulmonar/diagnóstico , Uganda , Vietnã
3.
medRxiv ; 2023 Aug 15.
Artigo em Inglês | MEDLINE | ID: mdl-37645869

RESUMO

Background: Reliance on sputum-based testing is a key barrier to increasing access to molecular diagnostics for tuberculosis (TB). Many people with TB are unable to produce and sputum processing increases the complexity and cost of molecular assays. Tongue swabs are emerging as an alternative to sputum, but performance limits are uncertain. Methods: From June 2022 to July 2023, we enrolled 397 consecutive adults with cough >2 weeks at two health centers in Kampala, Uganda. We collected routine demographic and clinical information, sputum for routine TB testing (one Xpert MTB/RIF Ultra® and two liquid cultures), and up to four tongue swabs for same-day qPCR. We evaluated tongue swab qPCR diagnostic accuracy in reference to sputum TB test results, quantified TB targets per swab, assessed the impact of serial swabbing, and compared two swab types (Copan FLOQSWAB® and Steripack® spun polyester swabs). Results: Among 397 participants, 43.1% were female, median age was 33 years, 23.5% were living with HIV (PLHIV) and 32.3% had confirmed TB. Sputum Xpert Ultra and tongue swab qPCR results were concordant for 98.2% [96.2-99.1] of participants. Tongue swab qPCR sensitivity was 91.0% [84.6-94.9] and specificity 98.9% [96.2-99.8] vs. microbiological reference standard (MRS). A single tongue swab recovered a seven-log range of TB copies, with a decreasing recovery trend among four serial swabs. We found no difference between swab types. Conclusions: Tongue swabs show promise as an alternative to sputum for TB diagnosis, with sensitivity approaching sputum-based molecular tests. Our results provide valuable insights for developing successful tongue swab-based TB diagnostics.

4.
PLoS One ; 16(7): e0254156, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34310609

RESUMO

Detection of tuberculosis at the point-of-care (POC) is limited by the low sensitivity of current commercially available tests. We describe a diagnostic accuracy field evaluation of a prototype urine Tuberculosis Lipoarabinomannan Lateral Flow Assay (TB-LAM LFA) in both HIV-positive and HIV-negative patients using fresh samples with sensitivity and specificity as the measures of accuracy. This prototype combines a proprietary concentration system with a sensitive LFA. In a prospective study of 292 patients with suspected pulmonary tuberculosis in Uganda, the clinical sensitivity and specificity was compared against a microbiological reference standard including sputum Xpert MTB/RIF Ultra and solid and liquid culture. TB-LAM LFA had an overall sensitivity of 60% (95%CI 51-69%) and specificity of 80% (95%CI 73-85%). When comparing HIV-positive (N = 86) and HIV-negative (N = 206) patients, there was no significant difference in sensitivity (sensitivity difference 8%, 95%CI -11% to +24%, p = 0.4351) or specificity (specificity difference -9%, 95%CI -24% to +4%, p = 0.2051). Compared to the commercially available Alere Determine TB-LAM Ag test, the TB-LAM LFA prototype had improved sensitivity in both HIV-negative (difference 49%, 95%CI 37% to 59%, p<0.0001) and HIV-positive patients with CD4+ T-cell counts >200cells/µL (difference 59%, 95%CI 32% to 75%, p = 0.0009). This report is the first to show improved performance of a urine TB LAM test for HIV-negative patients in a high TB burden setting. We also offer potential assay refinement solutions that may further improve sensitivity and specificity.


Assuntos
Infecções por HIV/urina , Soropositividade para HIV/urina , Lipopolissacarídeos/urina , Tuberculose/urina , Adulto , Feminino , HIV/patogenicidade , Infecções por HIV/complicações , Infecções por HIV/microbiologia , Infecções por HIV/virologia , Soropositividade para HIV/microbiologia , Soropositividade para HIV/virologia , Humanos , Masculino , Testes Imediatos , Escarro/microbiologia , Escarro/virologia , Tuberculose/complicações , Tuberculose/microbiologia , Tuberculose/virologia , Uganda/epidemiologia , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa