Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 24
Filtrar
1.
Circulation ; 122(19): 1928-36, 2010 Nov 09.
Artigo em Inglês | MEDLINE | ID: mdl-20975002

RESUMO

BACKGROUND: Patients with severe aortic stenosis and reduced left ventricular ejection fraction (LVEF) have a poor prognosis with conservative therapy but a high operative mortality when treated surgically. Recently, transcatheter aortic valve implantation (TAVI) has emerged as an alternative to surgical aortic valve replacement (SAVR) for patients considered at high or prohibitive operative risk. The objective of this study was to compare TAVI and SAVR with respect to postoperative recovery of LVEF in patients with severe aortic stenosis and reduced LV systolic function. METHODS AND RESULTS: Echocardiographic data were prospectively collected before and after the procedure in 200 patients undergoing SAVR and 83 patients undergoing TAVI for severe aortic stenosis (aortic valve area ≤1 cm(2)) with reduced LV systolic function (LVEF ≤50%). TAVI patients were significantly older (81±8 versus 70±10 years; P<0.0001) and had more comorbidities compared with SAVR patients. Despite similar baseline LVEF (34±11% versus 34±10%), TAVI patients had better recovery of LVEF compared with SAVR patients (ΔLVEF, 14±15% versus 7±11%; P=0.005). At the 1-year follow-up, 58% of TAVI patients had a normalization of LVEF (>50%) as opposed to 20% in the SAVR group. On multivariable analysis, female gender (P=0.004), lower LVEF at baseline (P=0.005), absence of atrial fibrillation (P=0.01), TAVI (P=0.007), and larger increase in aortic valve area after the procedure (P=0.01) were independently associated with better recovery of LVEF. CONCLUSION: In patients with severe aortic stenosis and depressed LV systolic function, TAVI is associated with better LVEF recovery compared with SAVR. TAVI may provide an interesting alternative to SAVR in patients with depressed LV systolic function considered at high surgical risk.


Assuntos
Estenose da Valva Aórtica/cirurgia , Implante de Prótese de Valva Cardíaca/métodos , Volume Sistólico/fisiologia , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/transplante , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/mortalidade , Estenose da Valva Aórtica/fisiopatologia , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/mortalidade , Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/cirurgia , Bioprótese , Ecocardiografia/métodos , Feminino , Próteses Valvulares Cardíacas , Implante de Prótese de Valva Cardíaca/mortalidade , Humanos , Masculino , Pessoa de Meia-Idade , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/mortalidade , Insuficiência da Valva Mitral/fisiopatologia , Insuficiência da Valva Mitral/cirurgia , Infarto do Miocárdio/complicações , Infarto do Miocárdio/epidemiologia , Caracteres Sexuais , Acidente Vascular Cerebral/epidemiologia , Acidente Vascular Cerebral/mortalidade , Resultado do Tratamento , Função Ventricular Esquerda/fisiologia
2.
Eur J Clin Invest ; 39(1): 1-10, 2009 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-19087125

RESUMO

BACKGROUND: Cardiac resynchronization therapy (CRT) has been shown to reduce heart failure related morbidity and mortality. However, approximately 30% of patients do not respond to CRT. We investigated the usefulness of Echo Doppler parameters to predict reverse remodelling, functional improvement and mortality following CRT. MATERIALS AND METHODS: Our population consists of 200 consecutive heart failure patients evaluated for ventricular dyssynchrony by echocardiography between February 1999 and May 2007 who subsequently received CRT. Patients were reassessed for signs of reverse remodelling after a mean follow-up of 10 months. Information on vital status was obtained from local registration authorities. RESULTS: Three parameters significantly predicted reverse remodelling in the logistic regression analysis: the Q-to-E-wave-delay (QED) at a cutoff of 550 ms (odds ratio 4.5, P-value 0.001), the interventricular mechanical delay (IVMD) at a cutoff of 60 ms (odds ratio 2.4, P-value 0.02), and the aortic electromechanical delay (A-EMD) at a cutoff of 140 ms (odds ratio 2.9, P-value 0.004). Furthermore, the QED and the IVMD also predicted all-cause mortality (hazard ratio 0.36, P-value 0.02 and 0.21, P-value 0.004, respectively). Adjustment for confounders did not alter the results. CONCLUSIONS: The QED and IVMD predict reverse remodelling and survival following CRT. These parameters are easy to obtain, provide valuable prognostic information, and should thus be measured in CRT candidates evaluated by echocardiography.


Assuntos
Estimulação Cardíaca Artificial , Ecocardiografia Doppler/métodos , Insuficiência Cardíaca/terapia , Remodelação Ventricular/fisiologia , Idoso , Ecocardiografia Doppler/normas , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Estudos Retrospectivos
3.
J Am Coll Cardiol ; 25(5): 1039-45, 1995 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-7897114

RESUMO

OBJECTIVES: This study sought to determine the feasibility of coronary sinus flow velocity analysis by transesophageal Doppler echocardiography for estimation of coronary flow reserve in patients with syndrome X and patients with coronary artery disease. BACKGROUND: Coronary flow reserve provides useful information in patients with coronary artery disease and patients with syndrome X. Current methods of measuring coronary flow reserve are invasive or require extensive laboratory equipment, or both. Transesophageal Doppler recordings of coronary sinus flow velocity before and after vasodilator application may allow noninvasive determination of coronary flow reserve. METHODS: We obtained coronary sinus flow velocity recordings before and after dipyridamole administration (0.6 mg/kg body weight per 5 min) in 9 patients with syndrome X, 14 with significant left coronary artery disease and 22 age-matched control patients. We used the formula anterograde minus retrograde flow velocity time integral times heart rate as an index of coronary sinus flow. Coronary flow reserve was calculated by dividing coronary sinus flow variables after dipyridamole administration by the respective baseline values. RESULTS: Technically adequate recordings were obtained in 44 (98%) of 45 patients. Compared with that in the control group (2.78 +/- 0.95 [mean +/- SD]), coronary flow reserve was significantly lower in patients with syndrome X (1.21 +/- 0.23, p < or = 0.001) as well as in those with coronary artery disease (1.47 +/- 0.7, p < or = 0.001). Using a cutoff coronary flow reserve value of 1.8, sensitivity, specificity and overall predictive value of coronary flow reserve determinations were, respectively, 100%, 91% and 94% for syndrome X and 86%, 91% and 89% for coronary artery disease. CONCLUSIONS: Coronary flow reserve calculation by transesophageal coronary sinus flow velocity recordings is feasible in a large proportion of patients and might be useful for the noninvasive evaluation of patients with syndrome X and patients with severe left coronary artery disease.


Assuntos
Circulação Coronária/fisiologia , Doença das Coronárias/diagnóstico por imagem , Ecocardiografia Doppler/métodos , Ecocardiografia Transesofagiana/métodos , Angina Microvascular/diagnóstico por imagem , Velocidade do Fluxo Sanguíneo/efeitos dos fármacos , Velocidade do Fluxo Sanguíneo/fisiologia , Circulação Coronária/efeitos dos fármacos , Doença das Coronárias/fisiopatologia , Dipiridamol , Eletrocardiografia , Estudos de Viabilidade , Feminino , Humanos , Masculino , Angina Microvascular/fisiopatologia , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Sensibilidade e Especificidade
4.
J Am Coll Cardiol ; 35(1): 230-7, 2000 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-10636285

RESUMO

OBJECTIVES: This study investigated the feasibility, accuracy and clinical potential of creating polymer hard copies of echocardiographic data using stereolithography. BACKGROUND: Three-dimensional (3D) echocardiography has so far been limited by the need to display reconstructed 3D objects on a two-dimensional screen. Thus, tangible stereolithographic polymer models created from echocardiographic data could enhance our spatial perception of cardiac anatomy and pathology. METHODS: Hard-copy replicas of water-filled latex balloon phantoms (n = 7) and porcine liver specimens (n = 12) were generated from echocardiographic images using stereolithography (computerized laser polymerization). In addition, we created 24 models of the mitral valve from 12 transesophageal studies (normal = 6, mitral stenosis n = 4, prolapse/flail leaflet n = 8, annular dilation n = 2, leaflet restriction n = 2 and following mitral valve repair n = 2). RESULTS: Excellent agreement was found for comparison of volumes (r = 0.98, SEE = 3.46 mm3, mean difference = 0.25 +/- 3.33 mm3) and maximal dimensions (r = 0.99, SEE = 0.16 cm, mean difference = 0.03 +/- 0.16 cm) between phantoms and their corresponding replicas. Visual and tactile examination of mitral valve models by two blinded observers allowed correct depiction of mitral valve anatomy and pathology in all cases. CONCLUSIONS: Stereolithographic modeling of echocardiographic images is feasible and provides tangible polyacrylic models that are true to scale, shape and volume. Such models offer accurate depiction of mitral valve anatomy and pathology in patients studied with transesophageal echocardiography. This technique could have substantial impact on diagnosis, management and preoperative planning in complex cardiovascular disorders.


Assuntos
Ecocardiografia Transesofagiana/instrumentação , Processamento de Imagem Assistida por Computador/instrumentação , Modelos Cardiovasculares , Polímeros , Sistemas Computacionais , Doenças das Valvas Cardíacas/diagnóstico por imagem , Doenças das Valvas Cardíacas/cirurgia , Humanos , Fígado/anatomia & histologia , Fígado/diagnóstico por imagem , Fígado/patologia , Valva Mitral/diagnóstico por imagem , Valva Mitral/patologia , Imagens de Fantasmas
5.
Cardiovasc Res ; 36(1): 21-7, 1997 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-9415268

RESUMO

OBJECTIVE: The present study was performed to compare coronary flow reserve by transesophageal Doppler echocardiography and intracoronary Doppler flow wire measurements in patients with LAD disease. METHODS: 17 patients with various degree of LAD stenosis were studied. Intracoronary LAD Doppler measurements were performed at baseline and after intracoronary injection of 18 micrograms adenosine. Transesophageal coronary sinus and LAD Doppler measurements were performed at baseline and after intravenous dipyridamole (0.6 mg/kg/5 min). Coronary flow reserve was calculated as the ratio of hyperemic to baseline average peak velocities. RESULTS: Coronary flow reserve was 2.44 +/- 0.62 and 2.19 +/- 0.76 for proximal and distal intracoronary measurements and was 2.25 +/- 0.64 and 1.74 +/- 0.63 for transesophageal LAD- and coronary sinus measurements. Proximal intracoronary flow reserve significantly correlated with transesophageal coronary sinus (r = 0.73, p < or = 0.001) and LAD (r = 0.70, p < or = 0.005) measurements, whereas distal intracoronary flow reserve only correlated with transesophageal coronary sinus flow reserve (r = 0.56, p < or = 0.02). Receiver operating characteristic curve analysis demonstrated similar diagnostic accuracy of all applied techniques for detection of a significant LAD stenosis. CONCLUSIONS: Coronary flow reserve by both transesophageal techniques correlated with intracoronary Doppler flow wire measurements, however considerable discrepancies may occur in the individual patient.


Assuntos
Circulação Coronária , Doença das Coronárias/fisiopatologia , Ecocardiografia Doppler , Ecocardiografia Transesofagiana , Ultrassonografia de Intervenção , Adenosina/administração & dosagem , Fármacos Cardiovasculares/administração & dosagem , Angiografia Coronária , Doença das Coronárias/diagnóstico por imagem , Dipiridamol/administração & dosagem , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Sensibilidade e Especificidade , Vasodilatadores/administração & dosagem
6.
Thromb Haemost ; 79(2): 378-82, 1998 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-9493594

RESUMO

The effects of the selective alpha-1-adrenoceptor antagonist doxazosin on metabolic and fibrinolytic parameters were studied in hypertensive patients with various degrees of fasting plasma insulin levels (Group A: 22.5 +/- 3 microU/ml, Group B: 8.1 +/- 1.5 microU/ml; p <0.01) to disclose a potential link between a doxazosin-induced alteration of insulin and/or lipid metabolism and possible changes of these parameters on the fibrinolytic system. Doxazosin treatment resulted in a dose-dependent reduction of basal insulin levels in group A to 16 +/- 3 microU/ml; p <0.05. This finding was paralleled by a dose-dependent increase in t-PAmass concentration in the same patient group (basal t-PAmass from 9.7 +/- 1 to 15.5 +/- 2 ng/ml; p <0.05). As PAI-1 "active" as well as total antigen levels were not altered in parallel, the net effect on the endogenous fibrinolytic system is an increase of the fibrinolytic potential.


Assuntos
Anti-Hipertensivos/farmacologia , Anti-Hipertensivos/uso terapêutico , Doxazossina/farmacologia , Doxazossina/uso terapêutico , Fibrinólise/efeitos dos fármacos , Hipertensão/tratamento farmacológico , Resistência à Insulina , Relação Dose-Resposta a Droga , Humanos , Hipertensão/sangue , Hipertensão/fisiopatologia , Insulina/sangue , Masculino , Pessoa de Meia-Idade
7.
Immunol Lett ; 38(2): 103-9, 1993 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-8294137

RESUMO

Serological markers of cell-mediated immunity, i.e., soluble CD4, soluble interleukin-2 (Il-2) receptor and beta 2-microglobulin, were determined in 60 patients with dilated cardiomyopathy. Compared with normal healthy donors (n = 30) and controls who had coronary artery disease with preserved left ventricular function (n = 20), significantly increased levels associated with the New York Heart Association functional classes have been found in the cardiomyopathy patients, irrespectively of the etiology. Out of the immunological variables tested, serum-soluble CD4 most closely reflected the clinical and hemodynamic stage, predicted the presence of lymphocytic aggregates in the myocardium and correlated with the CD4/CD8 ratios of endomyocardial lymphocytes (r = 0.6, P < 0.05). Conversely, focal mononuclear infiltration of the myocardium was associated with significantly elevated CD4/CD8 ratios (2.1 +/- 0.6 vs. 1.3 +/- 0.2, P < 0.05), higher total numbers and percentages of endomyocardial lymphocytes expressing the pan T-markers CD2 and CD3, more CD45RO/UCHL1-positive cells and more CD4-positive T-helper cells, compared with non-reactive cases the lymphocytes of which were scattered throughout the myocardium. In conclusion, in a subset of cardiomyopathy patients lymphocytic clusters in the myocardium indicated an enhanced cellular immune response predominantly mediated by CD4-positive T-helper lymphocytes with active memory function. This immunopathological condition in the heart can be monitored by serum-soluble CD4.


Assuntos
Cardiomiopatia Dilatada/imunologia , Linfócitos T/imunologia , Antígenos CD4/sangue , Relação CD4-CD8 , Antígenos CD8/sangue , Cardiomiopatia Dilatada/patologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Miocárdio/patologia , Valor Preditivo dos Testes , Receptores de Interleucina-2/análise , Microglobulina beta-2/análise
8.
Am J Cardiol ; 80(7): 951-5, 1997 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-9382016

RESUMO

Recent studies suggest prophylactic intraaortic balloon-pulsation (IABP) in patients undergoing coronary reperfusion therapy. However, variable effects of IABP on coronary blood flow are reported. It is suggested that augmentation of coronary flow is more effective in patients with a compromised hemodynamic status, which might have potential relevance in selecting IABP treatment in patients undergoing reperfusion therapy.


Assuntos
Circulação Coronária , Doença das Coronárias/fisiopatologia , Balão Intra-Aórtico , Idoso , Doença das Coronárias/terapia , Vasos Coronários/fisiopatologia , Feminino , Hemodinâmica , Humanos , Masculino , Pessoa de Meia-Idade
9.
Intensive Care Med ; 23(3): 297-300, 1997 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-9083232

RESUMO

OBJECTIVE: To demonstrate that emergency aortic valve replacement can be successfully performed in patients with critical aortic stenosis and reduced left ventricular function even in cardiogenic shock with associated severe multiple organ failure. DESIGN: Retrospective, consecutive case series. SETTING: Multidisciplinary intensive care unit of a tertiary care university hospital. PATIENTS: Five patients admitted to the intensive care unit with critical aortic stenosis (aortic valve area 0.56 +/- 0.13 cm2) and greatly reduced left ventricular ejection fraction (20 +/- 3%) in prolonged cardiogenic shock and associated multiple organ failure (Multiple organ failure score 6.8 +/- 0.5; Acute Physiology, Age, and Chronic Health Evaluation III score 91 +/- 27). INTERVENTION: Emergency aortic valve replacement. RESULTS: All patients survived with full recovery of organ function. At follow-up (18 +/- 10 months) all patients were in New York Heart Association functional class I or II with improvement of left ventricular ejection fraction to 48 +/- 25%. CONCLUSIONS: This excellent outcome suggests that emergency aortic valve replacement should be strongly considered in patients with critical aortic stenosis even in cardiogenic shock and multiple organ failure.


Assuntos
Estenose da Valva Aórtica/cirurgia , Próteses Valvulares Cardíacas , Insuficiência de Múltiplos Órgãos/complicações , Choque Cardiogênico/etiologia , Adulto , Idoso , Valva Aórtica , Estenose da Valva Aórtica/complicações , Emergências , Feminino , Hemodinâmica , Humanos , Masculino , Estudos Retrospectivos
10.
Clin Cardiol ; 20(3): 225-31, 1997 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-9068907

RESUMO

BACKGROUND: Currently used methods for assessment of coronary flow reserve are invasive and require extensive laboratory equipment. Recently, noninvasive assessment of coronary flow reserve by transesophageal Doppler evaluation of coronary sinus (CS) or left anterior descending coronary artery (LAD) flow has been proposed. Direct comparison between these two techniques is lacking. METHODS: Doppler recordings of CS and LAD flow velocity were obtained before and after 0.6 mg/kg/5 min dipyridamole in 16 patients with significant stenosis of the LAD (Group A) and in 14 control patients (Group B). Flow recordings and all measurements were performed in a blinded manner. For assessment of coronary flow reserve, Doppler measurements after dipyridamole were divided by the respective baseline values. RESULTS: Doppler studies of the CS and LAD were feasible in 30 of 30 (100%) and 23 of 30 (71%) patients, respectively. Analyzing the maximum flow velocities, coronary flow reserve in Groups A and B was 1.18 +/- 0.28 and 1.68 +/- 0.53 with CS recordings and 1.78 +/- 0.83 and 2.51 +/- 0.76 with LAD recordings, respectively. Analyzing the velocity time integrals, coronary flow reserve in Groups A and B was 1.53 +/- 0.68 and 2.59 +/- 0.74 with CS recordings and 1.77 +/- 0.38 and 2.68 +/- 0.93 with LAD recordings, respectively. Correlation between LAD and CS recordings was 0.69 (p < 0.001), when coronary flow reserve was calculated from the velocity time integral and 0.68 (p < 0.001) when the maximum flow velocities were used. CONCLUSION: Both transesophageal Doppler techniques might be useful for noninvasive assessment of coronary flow reserve.


Assuntos
Velocidade do Fluxo Sanguíneo , Circulação Coronária , Ecocardiografia Doppler , Ecocardiografia Transesofagiana , Adulto , Artérias , Velocidade do Fluxo Sanguíneo/efeitos dos fármacos , Doença das Coronárias/fisiopatologia , Vasos Coronários/fisiopatologia , Dipiridamol , Feminino , Hemodinâmica/efeitos dos fármacos , Humanos , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Veias
11.
Clin Cardiol ; 21(4): 247-52, 1998 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-9562934

RESUMO

BACKGROUND AND HYPOTHESIS: Recent studies demonstrate the feasibility of coronary flow reserve measurements by transesophageal echocardiographic (TEE) Doppler recordings of coronary sinus or left anterior descending (LAD) coronary artery flow velocity for detecting stenoses of the LAD artery. This study compares coronary flow reserve measurements by Doppler TEE with thallium-201 (201Tl) single-photon emission computed tomography (SPECT) in patients with proximal single-vessel LAD stenosis. METHODS: Nineteen patients with various degrees of LAD stenosis (mean area stenosis 71 +/- 24%; range 24-96%) were studied. Area stenosis by quantitative coronary angiography was < 75% in 7 patients and > 75% in 12 patients. Transesophageal LAD and coronary sinus Doppler measurements were performed at baseline and after intravenous dipyridamole. Coronary flow reserve was calculated as the ratio of hyperemic to baseline average peak velocities. Predefined coronary flow reserve cut-off values of 1.8 for the coronary sinus method and of 2.0 for the LAD method were used for diagnosis of significant LAD stenosis. Results were compared with qualitative 201Tl dipyridamole SPECT. RESULTS: Overall predictive accuracy for diagnosis of > 75% LAD stenosis was 79% for 201Tl SPECT, 77% for the transesophageal LAD and 79% for the transesophageal coronary sinus technique. Concordant results between 201Tl SPECT and the LAD and coronary sinus Doppler methods were observed in 79% and 71% of patients, respectively. CONCLUSIONS: Thallium-201 SPECT and transesophageal Doppler assessment of coronary flow reserve have similar accuracy for diagnosing significant proximal LAD stenosis. Therefore, both transesophageal Doppler techniques might constitute another widely available, noninvasive method for assessment of left coronary artery disease, if disease location is proximal.


Assuntos
Doença das Coronárias/diagnóstico , Vasos Coronários/fisiologia , Ecocardiografia Transesofagiana , Tomografia Computadorizada de Emissão de Fóton Único , Velocidade do Fluxo Sanguíneo , Angiografia Coronária , Doença das Coronárias/fisiopatologia , Ecocardiografia Doppler , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Radioisótopos de Tálio
12.
Wien Klin Wochenschr ; 110(12): 446-8, 1998 Jun 26.
Artigo em Inglês | MEDLINE | ID: mdl-9677665

RESUMO

Necrotizing fasciitis is a rare but life-threatening infection of the subcutaneous tissue. In addition to Group A streptococci, polymicrobial infection with various aerobic and anaerobic gram positive or gram negative bacteria is frequently observed. The present case illustrates that a high level of clinical suspicion is necessary for early diagnosis of this disease and confirms the value of computed tomography in patients with sepsis of unknown origin. Because of rapid progression of the disease early debridement of necrotic tissue is mandatory for survival.


Assuntos
Diabetes Mellitus Tipo 2/diagnóstico por imagem , Fasciite Necrosante/diagnóstico por imagem , Tomografia Computadorizada por Raios X , Antibacterianos , Terapia Combinada , Desbridamento , Diabetes Mellitus Tipo 2/cirurgia , Diagnóstico Diferencial , Quimioterapia Combinada/uso terapêutico , Fasciite Necrosante/cirurgia , Humanos , Masculino , Pessoa de Meia-Idade , Choque Séptico/diagnóstico por imagem , Choque Séptico/cirurgia , Infecções Estafilocócicas/diagnóstico por imagem , Infecções Estafilocócicas/cirurgia , Viagem
13.
Wien Klin Wochenschr ; 108(24): 775-80, 1996 Dec 27.
Artigo em Inglês | MEDLINE | ID: mdl-9017889

RESUMO

Large epidemiological studies demonstrate only moderate reduction in the incidence of coronary artery disease by antihypertensive drug treatment. This is attributed to the prevalence of multiple risk factors in hypertensive patients and to possible adverse metabolic effects of antihypertensive drugs which may counteract their ability to reduce the risk of cardiovascular disease. The choices for pharmacological blood pressure reduction are divided between five classes with similar antihypertensive efficacy but markedly different influence on coronary risk factors. Hence, the clinician has to consider the prevalence of coexisting coronary risk factors, comorbidity as well as the efficacy, side effects, and mechanisms of drug action.


Assuntos
Anti-Hipertensivos/efeitos adversos , Glicemia/metabolismo , Hipertensão/tratamento farmacológico , Lipídeos/sangue , Anti-Hipertensivos/uso terapêutico , Doença das Coronárias/sangue , Doença das Coronárias/prevenção & controle , Humanos , Hipertensão/sangue , Fatores de Risco
14.
Wien Klin Wochenschr ; 108(13): 404-6, 1996.
Artigo em Inglês | MEDLINE | ID: mdl-8766425

RESUMO

An attempt was made to insert a balloon-tipped pulmonary arterial catheter (Swan-Ganz catheter) in a patient in cardiogenic shock during circulatory support by intraaortic balloon pumping, with a right jugular central venous catheter in place. Due to the low cardiac output it was impossible to advance the catheter tip into the pulmonary artery and after several futile attempts it was decided to withdraw the catheter. However, this was impossible because a knot had formed between the central venous catheter and the Swan-Ganz catheter and surgical removal become necessary. This is the first report on intravasal knot formation between two different catheters. This rare complication has to be included in the long list of complications associated with Swan Ganz catheterisation.


Assuntos
Cateterismo Venoso Central/instrumentação , Cateterismo de Swan-Ganz/instrumentação , Balão Intra-Aórtico/instrumentação , Choque Cardiogênico/diagnóstico por imagem , Idoso , Desenho de Equipamento , Falha de Equipamento , Feminino , Humanos , Radiografia , Choque Cardiogênico/terapia
15.
Med Arh ; 64(5): 300-2, 2010.
Artigo em Inglês | MEDLINE | ID: mdl-21287957

RESUMO

PURPOSE: To present the importance of stress echocardiography in diagnosis of low flow-low gradient aortic stenosis (AS). MATERIAL AND METHOD: Two patients were tested, one male patient, aged 62, weight 72 kg, height 172 cm, and BSA 1.86 cm2, and the other one was female, aged 59, weight 83 kg, height 168 cm and BSA, were found to have at least moderate ASs with low flow and low gradients at rest. Dobutamine stress test was performed using standard protocol starting at 2.5 mcg/kg/min at rest as continuous infusion and increasing every five minutes intervals with stepwise increase up to 20 mcg/kg/min. Monitoring with 12-lead ECG and blood pressure measurements at each step was performed. After completing the test, transthoracic echocardiography (TTE) showed in male patient increasing in transvalvular flow and gradients across aortic valve and ejection fraction (EF) measured by Simpson method increased from 33% at rest up to 40% following Dobutamine administration. EOA (effective aortic valve area) from 0.8 cm2 at rest increased insignificantly to 0.85 cm, (0.425 m2) afterwards. CONCLUSION: Final diagnosis therefore was severe aortic stenosis with preserved contractile reserve. The patient was scheduled for surgical valve replacement. In female patient after DST, the area of aortic valve increased significantly from 0.75 cm2 up to 1.05 cm2, while all transvalvular gradients remained almost unchanged. Pseudo-Aortic Stenosis and surgical valve replacement had not been indicated at this time.


Assuntos
Estenose da Valva Aórtica/diagnóstico por imagem , Ecocardiografia sob Estresse , Estenose da Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/cirurgia , Dobutamina , Feminino , Humanos , Masculino , Pessoa de Meia-Idade
18.
Heart ; 94(12): 1627-33, 2008 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-18381378

RESUMO

BACKGROUND: Impairment of myocardial flow reserve (MFR) in aortic stenosis (AS) with normal left ventricular function relates to the haemodynamic severity. OBJECTIVES: To investigate whether myocardial blood flow (MBF) and MFR differ in low-flow, low-gradient AS depending on whether there is underlying true-severe AS (TSAS) or pseudo-severe AS (PSAS). METHODS: In 36 patients with low-flow, low-gradient AS, dynamic [13N]ammonia PET perfusion imaging was performed at rest (n = 36) and during dipyridamole stress (n = 20) to quantify MBF and MFR. Dobutamine echocardiography was used to classify patients as TSAS (n = 18) or PSAS (n = 18) based on the indexed projected effective orifice area (EOA) at a normal flow rate of 250 ml/s (EOAI(proj )0.55 cm(2)/m(2)). RESULTS: Compared with healthy controls (n = 14), patients with low-flow, low-gradient AS had higher resting mean (SD) MBF (0.83 (0.21) vs 0.69 (0.09) ml/min/g, p = 0.001), reduced hyperaemic MBF (1.16 (0.31) vs 2.71 (0.50) ml/min/g, p<0.001) and impaired MFR (1.44 (0.44) vs 4.00 (0.91), p<0.001). Resting MBF and MFR correlated with indices of AS severity in low-flow, low-gradient AS with the strongest relationship observed for EOAI(proj) (r(s) = -0.50, p = 0.002 and r(s) = 0.61, p = 0.004, respectively). Compared with PSAS, TSAS had a trend to a higher resting MBF (0.90 (0.19) vs 0.77 (0.21) ml/min/g, p = 0.06), similar hyperaemic MBF (1.16 (0.31) vs 1.17 (0.32) ml/min/g, p = NS), but a significantly smaller MFR (1.19 (0.26) vs 1.76 (0.41), p = 0.003). An MFR <1.8 had an accuracy of 85% for distinguishing TSAS from PSAS. CONCLUSIONS: Low-flow, low-gradient AS is characterised by higher resting MBF and reduced MFR that relates to the AS severity. The degree of MFR impairment differs between TSAS and PSAS and may be of value for distinguishing these entities.


Assuntos
Estenose da Valva Aórtica/diagnóstico , Circulação Coronária/fisiologia , Adulto , Idoso , Estenose da Valva Aórtica/fisiopatologia , Velocidade do Fluxo Sanguíneo/fisiologia , Estudos de Casos e Controles , Ecocardiografia sob Estresse , Feminino , Humanos , Masculino , Tomografia por Emissão de Pósitrons , Adulto Jovem
19.
Crit Care Med ; 28(7): 2231-7, 2000 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-10921545

RESUMO

OBJECTIVE: We examined whether intrathoracic blood volume (ITBV) and total end-diastolic volume (TEDV), determined by the transpulmonary indicator dilution technique, adequately reflect preload changes during fluid administration in patients with reduced left ventricular function. DESIGN: A prospective, controlled, clinical study. SETTING: Medical intensive care unit in a university hospital. PATIENTS: A total of 18 sedated, mechanically ventilated, and moderately hypovolemic intensive care unit patients, eight with reduced left ventricular function (ejection fraction area, 24.9+/-8.0%, group A), ten with normal left ventricular function (ejection fraction area, 57.6+/-13.0%, group B). INTERVENTIONS: Continuous crystalloid infusion over 120 mins at a constant rate of 8 mL/kg/30 mins. MEASUREMENTS AND MAIN RESULTS: Stroke volume index, central venous pressure, pulmonary artery occlusion pressure (PAOP), TEDV, and ITBV were determined simultaneously at baseline and serially every 30 mins during continuous crystalloid infusion. A similar series of measurements was obtained during control conditions. Performance of various variables during fluid administration was assessed by time correlation analysis. Sensitivity for various variables defined as the ability to detect increasing amounts of administered fluid in individual patients was calculated. All examined variables increased during fluid administration and were unaffected during the control period. Mean time correlation (r2) was significantly higher for pressure monitoring (central venous pressure, r2 = 0.8281; PAOP, r2 = 0.5476) than for volume variables (TEDV, r2 = 0.0256; ITBV, r2 = 0.0729) in group A and was high for all variables in group B (central venous pressure, r2 = 0.7056; PAOP, r2 = 0.6241; TEDV, r2 = 0.49; ITBV, r2 = 0.4225). Sensitivities for central venous pressure, PAOP, TEDV, and ITBV after 120 min were 63%, 75%, 25%, and 25% in group A and 90%, 100%, 60%, and 60% in group B, respectively. CONCLUSION: This study demonstrates limitations of the transpulmonary indicator dilution technique for monitoring of intravascular volume in patients with reduced left ventricular function.


Assuntos
Cuidados Críticos , Hidratação , Hemodinâmica , Hipovolemia/terapia , Técnicas de Diluição do Indicador , Feminino , Humanos , Unidades de Terapia Intensiva , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Reprodutibilidade dos Testes
20.
Anaesth Intensive Care ; 25(3): 255-9, 1997 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-9209606

RESUMO

The longterm effects of ketamine on haemodynamic parameters and exogenous catecholamine requirements were studied in twenty-five critically ill patients with catecholamine-dependent heart failure. Following sedation with midazolam (0.15 +/- 0.07, mg.kg-1.h-1) and sufentanil (0.88 +/- 0.33 microgram.kg-1.h-1), patients with impaired left ventricular function (left ventricular ejection fraction area 30 +/- 7%) were randomly assigned to receive ketamine (2.5 +/- 0.9 mg.kg-1.h-1) and midazolam (Group A) or remained on sufentanil/midazolam (Group B). Haemodynamic measurements were performed throughout the first 24 hours after randomization. In group A cardiac index decreased by 21% (P = 0.01), mean arterial pressure increased by 13% (P = 0.01), mean pulmonary artery pressure by 14% (P = 0.04), pulmonary capillary wedge pressure by 20% (P = 0.03), and systemic vascular resistance index by 38% (P < 0.001). No significant cardiovascular effects were observed in Group B. Neither group had significant changes of exogenous catecholamine requirement. In conclusion, ketamine exhibits potential negative cardiovascular effects in patients with catecholamine-dependent heart failure. Therefore, ketamine should not be considered a first line drug for longterm sedation of patients with impaired left ventricular function.


Assuntos
Anestésicos Dissociativos/efeitos adversos , Anestésicos Intravenosos/farmacologia , Catecolaminas/uso terapêutico , Insuficiência Cardíaca/fisiopatologia , Hemodinâmica/efeitos dos fármacos , Ketamina/efeitos adversos , Sufentanil/farmacologia , Idoso , Anestésicos Dissociativos/farmacologia , Cuidados Críticos , Interações Medicamentosas , Quimioterapia Combinada , Feminino , Humanos , Hipnóticos e Sedativos/farmacologia , Infusões Intravenosas , Masculino , Midazolam/farmacologia , Pessoa de Meia-Idade , Respiração Artificial
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa