Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
1.
Circ J ; 88(4): 451-459, 2024 Mar 25.
Artigo em Inglês | MEDLINE | ID: mdl-36754386

RESUMO

BACKGROUND: This study investigated the impact and predictive factors of concomitant significant tricuspid regurgitation (TR) and evaluated the roles of right ventricle (RV) function and the etiology of TR in the clinical outcomes of patients with severe aortic stenosis undergoing transcatheter aortic valve implantation (TAVI).Methods and Results: We assessed grading of TR severity, TR etiology, and RV function in pre- and post-TAVI transthoracic echocardiograms for 678 patients at Keio University School of Medicine. TR etiology was divided into 3 groups: primary TR, ventricular functional TR (FTR), and atrial FTR. The primary outcomes were all-cause and cardiovascular death. At baseline, moderate or greater TR was found in 55 (8%) patients and, after adjustment for comorbidities, was associated with increased all-cause death (hazard ratio [HR] 2.11; 95% confidence interval [CI] 1.19-3.77; P=0.011) and cardiovascular death (HR 2.29; 95% CI 1.06-4.99; P=0.036). RV dysfunction (RVD) also remained an independent predictor of cardiovascular death (HR 2.06; 95% CI 1.03-4.14; P=0.042). Among the TR etiology groups, patients with ventricular FTR had the lowest survival rate (P<0.001). Patients with persistent RVD after TAVI had a higher risk of cardiovascular death than those with a normal or recovered RV function (P<0.001). CONCLUSIONS: The etiology of TR and RV function play an important role in predicting outcomes in concomitant TR patients undergoing TAVI.


Assuntos
Estenose da Valva Aórtica , Substituição da Valva Aórtica Transcateter , Insuficiência da Valva Tricúspide , Disfunção Ventricular Direita , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Insuficiência da Valva Tricúspide/cirurgia , Resultado do Tratamento , Disfunção Ventricular Direita/etiologia , Estenose da Valva Aórtica/complicações , Estenose da Valva Aórtica/cirurgia , Estudos Retrospectivos , Valva Aórtica/cirurgia
2.
J Am Heart Assoc ; 11(23): e026334, 2022 12 06.
Artigo em Inglês | MEDLINE | ID: mdl-36444836

RESUMO

Background Subclinical leaflet thrombosis, characterized by hypoattenuated leaflet thickening (HALT) on multidetector computed tomography, is common after transcatheter aortic valve replacement (TAVR). Because little is known about the long-term natural history of subclinical HALT, we aimed to investigate this in patients who underwent TAVR without using additional anticoagulation. Methods and Results We retrospectively evaluated patients who underwent TAVR with the Edwards SAPIEN-XT at our institute between October 2013 and December 2015. Patients were grouped according to the presence or absence of HALT within 1 year after TAVR (HALT and No-HALT groups). The primary outcome, defined as the composite of all-cause mortality, heart failure readmission, and ischemic stroke, was compared. Valve performance was assessed over time by transthoracic echocardiography. Among 124 patients (men: 29.1%; median age, 85 years), 27 (21.8%) showed HALT on multidetector computed tomography within 1 year after TAVR. No patient required additional anticoagulation for treating HALT because of the absence of valve-related symptomatic deterioration. During the median follow-up period of 4.7 years (interquartile range, 4.0-5.6), the rate of primary outcome and valve performance was not statistically different between the 2 groups (37.0% versus 38.1%; log-rank test P=0.92; mean pressure gradient, 9 mm Hg [8-14 mm Hg] versus 10 mm Hg [7-15 mm Hg]; P=0.51, respectively). Conclusions Approximately 20% of patients after TAVR had HALT within 1 year; however, that did not change the risk of subsequent adverse cardiovascular events or the valve performance with statistical significance for up to 5 years despite no additional anticoagulation therapy.


Assuntos
Substituição da Valva Aórtica Transcateter , Humanos , Idoso de 80 Anos ou mais , Substituição da Valva Aórtica Transcateter/efeitos adversos , Seguimentos , Estudos Retrospectivos
3.
Cardiovasc Interv Ther ; 37(4): 717-724, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-35129792

RESUMO

Several studies have demonstrated better hemodynamic stability of mechanically expanding valves following transcatheter aortic valve replacement (TAVR). This study aims to assess the expansion or recoil of transcatheter aortic valves using multidetector computed tomography (MDCT). This was a retrospective study. Among 873 patients who underwent TAVR with balloon-expandable (SAPIEN 3) or mechanically expanding valves (LOTUS) at Keio University Hospital between 2013 and 2020, those who underwent serial MDCT and echocardiographic assessment (pre-procedure, discharge, 6 months, 1 year, and 2 years post-TAVR) as our hospital protocol were included in this analysis (N = 30; LOTUS = 12; SAPIEN 3 = 18). The pre- and post-procedural echocardiographic data and the valve expansion rate evaluated by MDCT were compared between the groups. In LOTUS valves, late-phase expansion was observed on computed tomography (mean expansion rate, 83.8% at discharge and 86.8%, 2 years postoperative, p < 0.001), and a gradual increase in the aortic valve area was observed on echocardiography (aortic valve area: 1.45 cm2 at discharge and 1.51 cm2, 2 years postoperative, p = 0.01). Conversely, in SAPIEN 3, valve expansion was not seen in the late phase (mean expansion rate, 84.5% at discharge and 83.8%, 2 years postoperative) with a decrease in the aortic valve area (1.41 cm2 at discharge and 1.37 cm2, 2 years postoperative, p = 0.04). The expansion of the middle portion of the LOTUS valves was attributed to the increase in the aortic valve area. In conclusion, this study demonstrated the greater late-phase expansion and better valve performance of mechanically expanding valves.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/cirurgia , Humanos , Desenho de Prótese , Estudos Retrospectivos , Substituição da Valva Aórtica Transcateter/métodos , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa