Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Acute Med Surg ; 11(1): e969, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38774150

RESUMO

Background: Median sternotomy is a common surgical procedure during cardiac and pulmonary surgeries. There are many reports of patient injury associated with wire breakage. However, there are only a few reports of healthcare worker injuries by sternal wire. Case Presentation: A patient in his 70s, having a history of thoracic aorta replacement, collapsed suddenly and paramedics started mechanical chest compression. On hospital arrival, the emergency department nurse attempted to initiate manual chest compression but was injured by a sternal wire protrusion on the patient's chest. The emergency physician placed gauze on the sternal wire and continued manual chest compression, but the patient died. Conclusion: To prevent this injury, cardiopulmonary resuscitation (CPR) providers should consciously check the patient's chest. If they observe wire exposure, they should immediately place a gauze, pad or consider performing mechanical chest compression. Safety measures such as the installing rubber pads in the AED should be considered.

2.
Acute Med Surg ; 11(1): e965, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38828078

RESUMO

Background: Cannabidiol (CBD) products have increased in popularity in Japan in recent years, particularly among young people. Some CBD products contain tetrahydrocannabinol (THC), the main ingredient of cannabis, and its analogs, which are illegal in Japan and have become a social issue. This report discusses the safety of CBD products. Case Presentation: Five patients with symptoms of CBD ingestion, including nausea, presented to our hospital. Three of the products these patients ingested contained THC. Metabolites of THC were detected in the blood and urine of all three patients, although there were some discrepancies in the urine drug screening test (DS10®). These examination results differed even when the same product was consumed. Conclusion: CBD products are unsafe and may unintentionally contain THC. It is also important to understand that CBD can turn into THC, and the effective time needed to conduct urine drug screening.

3.
BMJ Case Rep ; 16(12)2023 Dec 23.
Artigo em Inglês | MEDLINE | ID: mdl-38142055

RESUMO

A woman in her 50s was transported to our hospital after experiencing a road traffic crash that led to a massive haemothorax and haemorrhagic shock due to a cervical vascular injury caused by the seat belt. Contrast-enhanced CT of the chest showed extravascular leakage of the contrast medium from the vicinity of the right subclavicular area and fluid accumulation in the thoracic cavity. The patient was intubated, and a thoracic drainage catheter was placed. She underwent angiography and embolisation of the right costocervical trunk, right thyrocervical trunk and right suprascapular artery using a gelatine sponge and 25% N-butylcyanoacrylate-Lipiodol. She was extubated on the second day after stabilisation of the respiratory and circulatory status. In cases where the bleeding vessel is known and an emergency thoracotomy can serve as a backup, embolisation by interventional radiology should be considered the initial treatment approach.


Assuntos
Choque Hemorrágico , Lesões do Sistema Vascular , Feminino , Humanos , Hemotórax/diagnóstico por imagem , Hemotórax/etiologia , Hemotórax/terapia , Cintos de Segurança/efeitos adversos , Choque Hemorrágico/etiologia , Choque Hemorrágico/terapia , Lesões do Sistema Vascular/diagnóstico por imagem , Lesões do Sistema Vascular/etiologia , Lesões do Sistema Vascular/terapia , Hemorragia/complicações , Acidentes de Trânsito
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa