Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
1.
Acta Radiol ; 54(6): 628-33, 2013 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-23474766

RESUMO

BACKGROUND: Dual-energy perfusion CT (DEpCT) directly represents the iodine distribution in lung parenchyma and low perfusion areas caused by intrapulmonary clots (IPCs) are visualized as low attenuation areas. PURPOSE: To evaluate if volumetric evaluation of DEpCT can be used as a predictor of right heart strain by the presence of IPCs. MATERIAL AND METHODS: One hundred and ninety-six patients suspected of having acute pulmonary embolism (PE) underwent DEpCT using a 64-slice dual-source CT. DEpCT images were three-dimensionally reconstructed with four threshold ranges: 1-120 HU (V120), 1-15 HU (V15), 1-10 HU (V10), and 1-5 HU (V5). Each relative ratio per V120 was expressed as the %V15, %V10, and %V5. Volumetric data-sets were compared with D-dimer, pulmonary arterial (PA) pressure, right ventricular (RV) diameter, RV/left ventricular (RV/LV) diameter ratio, PA diameter, and PA/aorta (PA/Ao) diameter ratio. The areas under the ROC curves (AUCs) were examined for their relationship to the presence of IPCs. This study was approved by the local ethics committee. RESULTS: PA pressure and D-dimer were significantly higher in the patients who had IPCs. In the patients with IPCs, V15, V10, V5, %V15, %V10, and %V5 were also significantly higher than those without IPC (P ≤ 0.001). %V5 had a better correlation with D-dimer (r = 0.30, P < 0.001) and RV/LV diameter ratio (r = 0.27, P < 0.001), and showed a higher AUC (0.73) than the other CT measurements. CONCLUSION: The volumetric evaluation by DEpCT had a correlation with D-dimer and RV/LV diameter ratio, and the relative ratio of volumetric CT measurements with a lower attenuation threshold might be recommended for the analysis of acute PE.


Assuntos
Embolia Pulmonar/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Feminino , Produtos de Degradação da Fibrina e do Fibrinogênio/análise , Ventrículos do Coração/diagnóstico por imagem , Humanos , Imageamento Tridimensional , Iohexol , Masculino , Pessoa de Meia-Idade , Curva ROC
2.
Br J Radiol ; 95(1135): 20210854, 2022 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-35348358

RESUMO

OBJECTIVE: Major liver resection is an effective treatment option for patients with liver malignancy. The future liver remnant (FLR) volume and complications after portal vein embolization (PVE) were compared between the ipsilateral right portal vein (PTPE) and transileocolic (TIPE) approaches. METHODS: A total of 42 patients (TIPE, n = 22; PTPE, n = 20) underwent right lobectomy after PVE. CT and hepatobiliary scintigraphy were repeated before and after PVE. The blood examination findings and the FLR values (FLRCT: calculated from CT, %FLRCT: FLRCT ratio, %FLRSPECT: FLR ratio using single photon emission CT, FLRCT/BS: FLRCT to body surface ratio) were compared between two approach sites. The complications and mortality were also analyzed after PVE and major right hepatectomy. RESULTS: There were no significant differences in the patient characteristics, blood examination findings or FLR values between two groups. Adequate liver regeneration was observed without significant differences between PTPE and TIPE (increased ratio of FLRCT: 8.7% vs 19.2%, p = 0.15 [25-75 percentile: 17.1-60.4], %FLRCT: 11.2% vs 8.3%, p = 0.25 [6.3-13.3], %FLRSPECT: 15.4% vs 19.2%, p = 0.09 [16.0-22.4], FLRCT/BS: 33.6% vs 47.1%, p = 0.19 [17.2-60.4], respectively), but TIPE required a significantly longer procedure time than PTPE [181.4 min vs 108.7 min, p < 0.01 (103.3-193.5)]. However, one patient was converted to TIPE due to bleeding during PTPE. After right lobectomy, portal vein stenosis or thrombosis was noted in three patients [two with TIPE (9.1%) and one with PTPE (5%)] and three TIPE patients died within 90 days (13.6%) after right hepatectomy. CONCLUSION: FLR volume significantly increased after PVE, regardless of the approach sites; however, PTPE is a useful technique with a shorter procedure time.


Assuntos
Embolização Terapêutica , Neoplasias Hepáticas , Embolização Terapêutica/métodos , Hepatectomia/métodos , Humanos , Fígado/diagnóstico por imagem , Fígado/patologia , Fígado/cirurgia , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/cirurgia , Veia Porta/patologia , Resultado do Tratamento
3.
Jpn J Radiol ; 39(9): 857-867, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-34021462

RESUMO

Granulocyte colony-stimulating factor (G-CSF)-producing tumors have an aggressive clinical course. Here, we report five cases of G-CSF-producing tumors and review the literature, focusing on imaging findings related to tumor-produced G-CSF. In addition to our cases, we identified 30 previous reports of G-CSF-producing tumors on which 18F-fluorodeoxyglucose positron emission tomography (FDG-PET)/CT, bone scintigraphy, or evaluation of bone marrow MR findings was performed. White blood cell count, serum C-reactive protein, and serum interleukin-6 were elevated in all cases for which these parameters were measured. G-CSF-producing tumors presented large necrotic masses (mean diameter 83.2 mm, range 17-195 mm) with marked FDG uptake (mean maximum standardized uptake value: 20.09). Diffuse FDG uptake into the bone marrow was shown in 28 of the 31 cases in which FDG-PET/CT was performed. The signal intensity of bone marrow suggested marrow reconversion in all seven MRI-assessable cases. Bone scintigraphy demonstrated no significant uptake, except in two cases with bone metastases. Splenic FDG uptake was increased in 8 of 10 cases in which it was evaluated. These imaging findings may reflect the effects of tumor-produced G-CSF. The presence of G-CSF-producing tumors should be considered in patients with cancer who show these imaging findings and marked inflammatory features of unknown origin.


Assuntos
Neoplasias Ósseas , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Fluordesoxiglucose F18 , Fator Estimulador de Colônias de Granulócitos , Humanos , Tomografia Computadorizada por Raios X
4.
Abdom Radiol (NY) ; 45(11): 3755-3762, 2020 11.
Artigo em Inglês | MEDLINE | ID: mdl-32382819

RESUMO

PURPOSE: To compare the image quality of multiphasic (arterial, portal, and equilibrium phases) dynamic computed tomography (CT) of the abdomen obtained by a low tube voltage (70kVp) in combination with a half-dose iodine load using low-concentration contrast agent in high tube output dual-source CT with a standard tube voltage (120kVp) and full-dose iodine load using the same group of adult patients. METHODS: Fifty-five patients who underwent both low-tube-voltage (70kVp) abdominal CT with a half-dose iodine load and standard-tube-voltage (120kVp) CT with a full-dose iodine load were analyzed. The mean CT values and signal-to-noise ratio (SNR) of the liver, aorta and portal veins were quantitatively assessed. In addition, the contrast enhancement of the abdominal organs and overall image quality were qualitatively evaluated. RESULTS: The mean CT values and SNR of the liver parenchyma were significantly higher in 70-kVp protocol than in 120-kVp protocol in all 3 phases (p = 0.018 ~ < 0.001). Regarding the qualitative analysis, the overall image quality in the 70-kVp protocol was significantly better than in the 120-kVp protocol in all 3 phases (p < 0.001). In addition, the contrast enhancement scores of the liver parenchyma and hepatic vein in the equilibrium phase were also significantly higher in the 70-kVp protocol than in the 120-kVp protocol (p < 0.001). CONCLUSION: A low tube voltage (70kVp) in combination with a half-dose iodine load using a low-concentration contrast agent and an iterative reconstruction algorithm in high tube output dual-source CT may improve the contrast enhancement and image quality in multiphasic dynamic CT of the abdomen in patients under 71 kg of body weight.


Assuntos
Redução da Medicação , Interpretação de Imagem Radiográfica Assistida por Computador , Abdome/diagnóstico por imagem , Adulto , Meios de Contraste , Humanos , Doses de Radiação , Tomografia Computadorizada por Raios X
5.
Abdom Radiol (NY) ; 45(3): 774-781, 2020 03.
Artigo em Inglês | MEDLINE | ID: mdl-31832740

RESUMO

PURPOSE: To determine imaging findings of pancreatic adenocarcinomas incidentally detected on contrast-enhanced multiphasic dynamic computed tomography (CT) obtained during the follow-up for other diseases. METHODS: From January 2007 to December 2018, 14 patients with pancreatic adenocarcinomas incidentally detected on CT obtained during the follow-up for other diseases (incidental group) and 105 patients with pancreatic adenocarcinomas symptomatically detected on ultrasound or CT (non-incidental group) were included. Imaging characteristics of the tumor were compared between the two groups. Additionally, imaging findings prior to the detection of a tumor on previous CT images in the incidental group were also assessed. RESULTS: In cancers of the pancreas body/tail, there was a significantly smaller tumor size (median, 17 mm vs. 42 mm, p < 0.001), a significantly lower incidence of loss of fatty marbling (p = 0.025), vascular involvement (p < 0.001), lymph node metastasis (p = 0.046) and distant metastasis (p = 0.017), and a significantly higher incidence of preserved lobulation (p < 0.001) in the incidental group than in the non-incidental group. Regarding the cancers of the pancreas head, there were no significant differences in the radiological findings between the two groups. On previous CT images, small pancreatic nodules, secondary signs, and loss of fatty marbling tended to be the preceding findings of incidental pancreatic adenocarcinomas. CONCLUSION: Incidentally detected pancreatic adenocarcinomas in the pancreas body/tail were characterized by an earlier tumor stage than in cases of symptomatically detected pancreatic adenocarcinoma. Several CT findings prior to the detection of a tumor may be useful for the early detection of pancreatic adenocarcinoma during the follow-up for other diseases.


Assuntos
Adenocarcinoma/diagnóstico por imagem , Achados Incidentais , Neoplasias Pancreáticas/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Adenocarcinoma/patologia , Idoso , Idoso de 80 Anos ou mais , Meios de Contraste , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Estadiamento de Neoplasias , Neoplasias Pancreáticas/patologia , Estudos Retrospectivos
6.
Jpn J Radiol ; 37(9): 651-659, 2019 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-31321619

RESUMO

PURPOSE: To determine the consistency of major hepatocellular carcinoma (HCC) features between CT and MRI based on Liver Imaging Reporting and Data System (LI-RADS) v2018 and to investigate the additional value on gadoxetic acid-enhanced MRI. MATERIALS AND METHODS: Patients who underwent dynamic CT and gadoxetic acid-enhanced MRI within 1 month were investigated. Two radiologists evaluated the presence of major HCC features and categorized observations using LI-RADS v2018 algorithm. In addition, each observation was recorded as hyper-, iso-, or hypo-intensity on hepatobiliary-phase (HBP) images. RESULTS: Sixty-one patients with 110 observations were identified. Among 88 observations classified as LR-3, 4 or 5, arterial phase hyper-enhancement and washout appearance showed higher frequencies on CT than on MRI (75.0% vs. 58.0%, P < 0.001, and 60.2% vs. 44.3%, P = 0.014, respectively). Of the 59 LR-3 observations categorized on MRI, 70.0% of observations with hypo-intensity on HBP images were HCCs, whereas 89.5% of observations with iso- or hyper-intensity on HBP images were non-HCCs (P < 0.001) CONCLUSION: The frequencies of arterial phase hyper-enhancement and washout appearances were higher on CT than on gadoxetic acid-enhanced MRI. For LR-3 observations, adding the hepatobiliary-phase hypo-intensity to major features improved the diagnostic performance of MRI in distinguishing HCCs from non-HCC lesions.


Assuntos
Carcinoma Hepatocelular/diagnóstico por imagem , Gadolínio DTPA , Aumento da Imagem/métodos , Neoplasias Hepáticas/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Sistemas de Informação em Radiologia , Tomografia Computadorizada por Raios X/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Algoritmos , Meios de Contraste , Feminino , Humanos , Fígado/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Sensibilidade e Especificidade
7.
Eur J Radiol ; 84(8): 1614-1620, 2015 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-26037265

RESUMO

OBJECTIVES: Factors affecting the improvement in the lung perfused blood volume (LPBV) were evaluated based on the presence of intrapulmonary clots (IPCs) after anti-coagulation therapy using 64-slice dual-energy CT. MATERIALS AND METHODS: 96 patients exhibiting venous thromboembolism underwent initial and repeated LPBV examinations between December 2008 and July 2014. Fifteen patients were excluded due to pulmonary comorbidities, and a total of 81 patients were included in this study. Acute pulmonary embolism (PE) was diagnosed in 46 of the patients (56.7%). LPBV images were three-dimensionally reconstructed with two threshold ranges: 1-120 HU (V120) and 1-5 HU (V5), and the relative value of V5 per V120 expressed as %V5. These values were subsequently compared with indicators of the severity of PE, such as the D-dimer level, heart rate and CT measurements. This study was approved by the local ethics committee. RESULTS: In patients with IPCs, the D-dimer, V5 and %V5values were significantly larger (p≤0.01) in the initial LPBV, although these differences disappeared in subsequent LPBV after treatment. The right ventricular (RV) diameter, RV/left ventricular (RV/LV) diameter ratio and %V5 values were also significantly reduced, whereas the V5 value did not significantly decrease (p=0.07), but V120 value significantly increased (p<0.001) after treatment. However, in patients with IPCs the change rate in %V5 [(subsequent-initial)/initial %V5] showed a better correlation with that in V5 (r=0.94, p<0.001) rate than that in V120 (r=0.19, p=0.19) after treatment. CONCLUSIONS: Increased whole lung perfusion (V120) and a decreased low perfusion volume (V5) affect the improvement in the %V5 values after treatment.


Assuntos
Anticoagulantes/uso terapêutico , Coagulação Sanguínea/efeitos dos fármacos , Volume Sanguíneo/fisiologia , Embolia Pulmonar/tratamento farmacológico , Embolia Pulmonar/fisiopatologia , Tomografia Computadorizada por Raios X/métodos , Coagulação Sanguínea/fisiologia , Volume Sanguíneo/efeitos dos fármacos , Feminino , Humanos , Imageamento Tridimensional , Pulmão/diagnóstico por imagem , Pulmão/fisiopatologia , Masculino , Pessoa de Meia-Idade , Circulação Pulmonar/efeitos dos fármacos , Circulação Pulmonar/fisiologia , Embolia Pulmonar/diagnóstico por imagem , Índice de Gravidade de Doença
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa