Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Artigo em Inglês | MEDLINE | ID: mdl-32824908

RESUMO

Several epidemiological studies found an association between acute exposure to fine particulate matter of less than 2.5 µm and 10 µm in aerodynamic diameter (PM2.5 and PM10) and cardiovascular diseases, ventricular fibrillation incidence and mortality. The effects of pollution on atrial fibrillation (AF) beyond the first several hours of exposure remain controversial. A total of 145 patients with implantable cardioverter-defibrillators (ICDs), cardiac resynchronization therapy defibrillators (ICD-CRT), or pacemakers were enrolled in this multicentric prospective study. Daily levels of PM2.5 and PM10 were collected from monitoring stations within 20 km of the patient's residence. A Firth Logistic Regression model was used to evaluate the association between AF and daily exposure to PM2.5 and PM10. Exposure levels to PM2.5 and PM10 were moderate, being above the World Health Organization (WHO) PM2.5 and PM10 thresholds of 25 µg/m3 and 50 µg/m3, respectively, on 26% and 18% of the follow-up days. An association was found between daily levels of PM2.5 and PM10 and AF (95% confidence intervals (CIs) of 1.34-2.40 and 1.44-4.28, respectively) for an increase of 50 µg/m3 above the WHO threshold. Daily exposure to moderate PM2.5 and PM10 levels is associated with AF in patients who are not prone to AF.


Assuntos
Poluentes Atmosféricos , Poluição do Ar , Fibrilação Atrial , Material Particulado , Idoso , Poluentes Atmosféricos/análise , Poluentes Atmosféricos/toxicidade , Poluição do Ar/análise , Fibrilação Atrial/epidemiologia , Exposição Ambiental , Feminino , Humanos , Masculino , Material Particulado/análise , Material Particulado/toxicidade , Pacientes , Estudos Prospectivos
2.
J Arrhythm ; 35(3): 562-564, 2019 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-31293710

RESUMO

We reported a case of inappropriate implantable cardioverter defibrillator shocks, due to atrial far-field on the tip-to-ring channel of the fast electrical activity during atrial fibrillation, caused by lead dislocation in the right ventricle outflow tract. During these episodes the can-to-right ventricle coil signal correctly recorded the ventricular activity. The shock storm stopped when an antitachycardia pacing restored sinus rhythm.

SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa