Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 204
Filtrar
1.
BMC Cancer ; 24(1): 767, 2024 Jun 26.
Artigo em Inglês | MEDLINE | ID: mdl-38926864

RESUMO

BACKGROUND: Breast cancer (BrCa) is a predominant malignancy, with metastasis occurring in one in eight patients, nearly half of which target the bone, leading to serious complications such as pain, fractures, and compromised mobility. Structural rigidity, crucial for bone strength, becomes compromised with osteolytic lesions, highlighting the vulnerability and increased fracture risk in affected areas. Historically, two-dimensional radiographs have been employed to predict these fracture risks; however, their limitations in capturing the three-dimensional structural and material changes in bone have raised concerns. Recent advances in CT-based Structural Rigidity Analysis (CTRA), offer a promising, more accurate non-invasive 3D approach. This study aims to assess the efficacy of CTRA in monitoring osteolytic lesions' progression and response to therapy, suggesting its potential superiority over existing methodologies in guiding treatment strategies. METHODS: Twenty-seven female nude rats underwent femoral intra-medullary inoculation with MDA-MB-231 human breast cancer cells or saline control. They were divided into Control, Cancer Control, Ibandronate, and Paclitaxel groups. Osteolytic progression was monitored weekly using biplanar radiography, quantitative computed tomography (QCT), and dual-energy X-ray absorptiometry (DEXA). CTRA was employed to predict fracture risk, normalized using the contralateral femur. Statistical analyses, including Kruskal-Wallis and ANOVA, assessed differences in outcomes among groups and over time. RESULTS: Biplanar radiographs showed treatment benefits over time; however, only certain time-specific differences between the Control and other treatment groups were discernible. Notably, observer subjectivity in X-ray scoring became evident, with significant inter-operator variations. DEXA measurements for metaphyseal Bone Mineral Content (BMC) did not exhibit notable differences between groups. Although diaphyseal BMC highlighted some variance, it did not reveal significant differences between treatments at specific time points, suggesting a limited ability for DEXA to differentiate between treatment effects. In contrast, the CTRA consistently demonstrated variations across different treatments, effectively capturing bone rigidity changes over time, and the axial- (EA), bending- (EI), and torsional rigidity (GJ) outcomes from the CTRA method successfully distinguished differences among treatments at specific time points. CONCLUSION: Traditional approaches, such as biplanar radiographs and DEXA, have exhibited inherent limitations, notably observer bias and time-specific inefficacies. Our study accentuates the capability of CTRA in capturing real-time, progressive changes in bone structure, with the potential to predict fractures more accurately and provide a more objective analysis. Ultimately, this innovative approach may bridge the existing gap in clinical guidelines, ushering in enhanced Clinical Decision Support Tool (CDST) for both surgical and non-surgical treatments.


Assuntos
Neoplasias Ósseas , Neoplasias da Mama , Tomografia Computadorizada por Raios X , Animais , Feminino , Ratos , Humanos , Tomografia Computadorizada por Raios X/métodos , Neoplasias Ósseas/secundário , Neoplasias Ósseas/diagnóstico por imagem , Neoplasias da Mama/patologia , Neoplasias da Mama/diagnóstico por imagem , Absorciometria de Fóton/métodos , Densidade Óssea , Ratos Nus , Paclitaxel/uso terapêutico , Paclitaxel/farmacologia , Paclitaxel/administração & dosagem , Linhagem Celular Tumoral , Osteólise/diagnóstico por imagem , Ácido Ibandrônico/uso terapêutico , Ácido Ibandrônico/farmacologia , Conservadores da Densidade Óssea/uso terapêutico , Conservadores da Densidade Óssea/farmacologia
2.
J Magn Reson Imaging ; 2024 Mar 25.
Artigo em Inglês | MEDLINE | ID: mdl-38526032

RESUMO

BACKGROUND: Osteoporosis (OP) and osteomalacia (OM) are metabolic bone diseases characterized by mineral and matrix density changes. Quantitative bone matrix density differentiates OM from OP. MRI is a noninvasive and nonionizing imaging technique that can measure bone matrix density quantitatively in ex vivo and in vivo. PURPOSE: To demonstrate water + fat suppressed 1H MRI to compute bone matrix density in ex vivo rat femurs in the preclinical model. STUDY TYPE: Prospective. ANIMAL MODEL: Fifteen skeletally mature female Sprague-Dawley rats, five per group (normal, ovariectomized (OVX), partially nephrectomized/vitamin D (Vit-D) deficient), 250-275 g, ∼15 weeks old. FIELD STRENGTH/SEQUENCE: 7T, zero echo time sequence with water + fat (VAPOR) suppression capability, µCT imaging, and gravimetric measurements. ASSESSMENT: Cortical and trabecular bone segments from normal and disease models were scanned in the same coil along with a dual calibration phantom for quantitative assessment of bone matrix density. STATISTICAL TESTS: ANOVA and linear regression were used for data analysis, with P-values <0.05 statistically significant. RESULTS: The MRI-derived three-density PEG pellet densities have a strong linear relationship with physical density measures (r2 = 0.99). The Vit-D group had the lowest bone matrix density for cortical bone (0.47 ± 0.16 g cm-3), whereas the OVX had the lowest bone matrix density for trabecular bone (0.26 ± 0.04 g cm-3). Gravimetry results confirmed these MRI-based observations for Vit-D cortical (0.51 ± 0.07 g cm-3) and OVX trabecular (0.26 ± 0.03 g cm-3) bone groups. DATA CONCLUSION: Rat femur images were obtained using a modified pulse sequence and a custom-designed double-tuned (1H/31P) transmit-receive solenoid-coil on a 7T preclinical MRI scanner. Phantom experiments confirmed a strong linear relation between MRI-derived and physical density measures and quantitative bone matrix densities in rat femurs from normal, OVX, and Vit-D deficient/partially nephrectomized animals were computed. LEVEL OF EVIDENCE: 2 TECHNICAL EFFICACY: Stage 2.

3.
BMC Musculoskelet Disord ; 25(1): 396, 2024 May 21.
Artigo em Inglês | MEDLINE | ID: mdl-38773483

RESUMO

PURPOSE: This systematic review aims to provide an overview of the current knowledge on the role of the metaverse, augmented reality, and virtual reality in reverse shoulder arthroplasty. METHODS: A systematic review was performed using the PRISMA guidelines. A comprehensive review of the applications of the metaverse, augmented reality, and virtual reality in in-vivo intraoperative navigation, in the training of orthopedic residents, and in the latest innovations proposed in ex-vivo studies was conducted. RESULTS: A total of 22 articles were included in the review. Data on navigated shoulder arthroplasty was extracted from 14 articles: seven hundred ninety-three patients treated with intraoperative navigated rTSA or aTSA were included. Also, three randomized control trials (RCTs) reported outcomes on a total of fifty-three orthopedics surgical residents and doctors receiving VR-based training for rTSA, which were also included in the review. Three studies reporting the latest VR and AR-based rTSA applications and two proof of concept studies were also included in the review. CONCLUSIONS: The metaverse, augmented reality, and virtual reality present immense potential for the future of orthopedic surgery. As these technologies advance, it is crucial to conduct additional research, foster development, and seamlessly integrate them into surgical education to fully harness their capabilities and transform the field. This evolution promises enhanced accuracy, expanded training opportunities, and improved surgical planning capabilities.


Assuntos
Artroplastia do Ombro , Realidade Aumentada , Realidade Virtual , Humanos , Artroplastia do Ombro/métodos , Cirurgia Assistida por Computador/educação , Cirurgia Assistida por Computador/métodos , Articulação do Ombro/cirurgia
4.
BMC Musculoskelet Disord ; 25(1): 157, 2024 Feb 19.
Artigo em Inglês | MEDLINE | ID: mdl-38373917

RESUMO

BACKGROUND: Anterior cruciate ligament (ACL) rupture is a common orthopedic injury, occurring in roughly 68.6 per 100,000 persons annually, with the primary treatment option being ACL reconstruction. However, debate remains about the appropriate graft type for restoring the native biomechanical properties of the knee. Furthermore, plastic graft elongation may promote increased knee laxity and instability without rupture. This study aims to investigate the plastic properties of common ACL-R graft options. METHODS: Patellar tendon (PT), hamstring tendon (HT), and quadriceps tendon (QT) grafts were harvested from 11 cadaveric knees (6 male and 5 female) with a mean age of 71(range 55-81). All grafts were mechanically tested under uniaxial tension until failure to determine each graft's elastic and plastic biomechanical properties. RESULTS: Mechanically, the QT graft was the weakest, exhibiting the lowest failure force and the lowest failure stress (QT < HT, p = 0.032). The PT was the stiffest of the grafts, having a significantly higher stiffness (PT > QT, p = 0.0002) and Young's modulus (PT > QT, p = 0.001; PT > HT, p = 0.041). The HT graft had the highest plastic elongation at 4.01 ± 1.32 mm (HT > PT, p = 0.002). The post-yield behavior of the HT tendon shows increased energy storage capabilities with the highest plastic energy storage (HT > QT, p = 0.012) and the highest toughness (HT > QT, p = 0.032). CONCLUSION: Our study agrees with prior studies indicating that the failure load of all grafts is above the requirements for everyday activities. However, grafts may be susceptible to yielding before failure during daily activities. This may result in the eventual loss of functionality for the neo-ACL, resulting in increased knee laxity and instability.


Assuntos
Lesões do Ligamento Cruzado Anterior , Ligamento Patelar , Masculino , Humanos , Feminino , Idoso , Ligamento Cruzado Anterior/cirurgia , Autoenxertos/cirurgia , Transplante Autólogo , Articulação do Joelho/cirurgia , Ligamento Patelar/cirurgia , Lesões do Ligamento Cruzado Anterior/cirurgia
5.
Int Orthop ; 48(1): 37-47, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38078940

RESUMO

PURPOSE: Low-velocity gunshot fractures (LVGFs) are a common type of gunshot-induced trauma with the potential for complications such as infection and osteomyelitis. The effectiveness of antibiotic therapy in LVGFs remains uncertain, leading to ongoing debate about the appropriate treatment. In this review, we evaluate recent updates on the current understanding of antibiotic therapy in LVGFs, how previous studies have investigated the use of antibiotics in LVGFs, and the current state of institutional policies and protocols for treating LVGFs with antibiotics. METHODS: We conducted a review of PubMed, Embase, and Web of Science databases to identify studies that investigated the use of antibiotics in LVGFs after the last review in 2013. Due to the lack of quantitative clinical trial studies, we employed a narrative synthesis approach to analyze and present the findings from the included primary studies. We categorized the outcomes based on the anatomical location of the LVGFs. RESULTS: After evaluating 67 publications with the necessary qualifications out of 578 abstracts, 17 articles were included. The sample size of the studies ranged from 22 to 252 patients. The antibiotics used in the studies varied, and the follow-up period ranged from three months to ten years. The included studies investigated the use of antibiotics in treating LVGFs at various anatomic locations, including the humerus, forearm, hand and wrist, hip, femur, tibia, and foot and ankle. CONCLUSION: Our study provides updated evidence for the use of antibiotics in LVGFs and highlights the need for further research to establish evidence-based guidelines. We also highlight the lack of institutional policies for treating LVGFs and the heterogeneity in treatments among institutions with established protocols. A single-dose antibiotic approach could be cost-effective for patients with non-operatively treated LVGFs. We suggest that a national or international registry for gunshot injuries, antibiotics, and infections could serve as a valuable resource for collecting and analyzing data related to these important healthcare issues.


Assuntos
Fraturas Ósseas , Osteomielite , Ferimentos por Arma de Fogo , Humanos , Antibioticoprofilaxia/efeitos adversos , Antibacterianos/uso terapêutico , Fraturas Ósseas/complicações , Tíbia , Osteomielite/tratamento farmacológico , Ferimentos por Arma de Fogo/complicações
6.
BMC Musculoskelet Disord ; 24(1): 105, 2023 Feb 07.
Artigo em Inglês | MEDLINE | ID: mdl-36750786

RESUMO

BACKGROUND: The current understanding of glenohumeral joint stability is defined by active restrictions and passive stabilizers including naturally-occurring negative intraarticular pressure. Cadaveric specimens have been used to evaluate the role of intraarticular pressure on joint stability, although, while the shoulder's negative intraarticular pressure is universally acknowledged, it has been inconsistently accounted for. HYPOTHESIS: During continuous, passive humeral abduction, releasing the native intraarticular pressure increases joint translation, and restoring this pressure decreases joint translations. STUDY DESIGN: Descriptive Laboratory Study. METHODS: A validated shoulder testing system was used to passively abduct the humerus in the scapular plane and measure joint translations for seven (n = 7) cadaveric specimens. The pressure within the glenohumeral joint was measured via a 25-gauge needle during passive abduction of the arm, which was released and subsequently restored. During motion, the rotator cuff muscles were loaded using stepper motors in a force feedback loop and electromagnetic sensors were used to continuously measure the position of the humerus and scapula. Joint translation was defined according to the instant center of rotation of the glenohumeral head according to the recommendations by the International Society of Biomechanics. RESULTS: Area under the translation versus abduction angle curve suggests that releasing the pressure within the capsule results in significantly less posterior translation of the glenohumeral head as compared to intact (85-90˚, p < 0.05). Posterior and superior translations were reduced after 70˚ of abduction when the pressure within the joint was restored. CONCLUSION: With our testing system employing a smooth continuous passive motion, we were able to show that releasing intraarticular pressure does not have a major effect on the path of humeral head motion during glenohumeral abduction. However, both violating the capsule and restoring intraarticular pressure after releasing alter glenohumeral translations. Future studies should study the effect of simultaneous external rotation and abduction on the relationship between joint motion and IAP, especially in higher degrees of abduction. CLINICAL RELEVANCE: Thoroughly simulating the glenohumeral joint environment in the cadaveric setting may strengthen the conclusions that can be translated from this setting to the clinic.


Assuntos
Articulação do Ombro , Ombro , Humanos , Fenômenos Biomecânicos , Articulação do Ombro/fisiologia , Cabeça do Úmero , Amplitude de Movimento Articular/fisiologia , Cadáver
7.
Proc Natl Acad Sci U S A ; 117(22): 12029-12040, 2020 06 02.
Artigo em Inglês | MEDLINE | ID: mdl-32404427

RESUMO

Hutchinson-Gilford progeria syndrome (HGPS) is a uniformly fatal condition that is especially prevalent in skin, cardiovascular, and musculoskeletal systems. A wide gap exists between our knowledge of the disease and a promising treatment or cure. The aim of this study was to first characterize the musculoskeletal phenotype of the homozygous G608G BAC-transgenic progeria mouse model, and to determine the phenotype changes of HGPS mice after a five-arm preclinical trial of different treatment combinations with lonafarnib, pravastatin, and zoledronic acid. Microcomputed tomography and CT-based rigidity analyses were performed to assess cortical and trabecular bone structure, density, and rigidity. Bones were loaded to failure with three-point bending to assess strength. Contrast-enhanced µCT imaging of mouse femurs was performed to measure glycosaminoglycan content, thickness, and volume of the femoral head articular cartilage. Advanced glycation end products were assessed with a fluorometric assay. The changes demonstrated in the cortical bone structure, rigidity, stiffness, and modulus of the HGPS G608G mouse model may increase the risk for bending and deformation, which could result in the skeletal dysplasia characteristic of HGPS. Cartilage abnormalities seen in this HGPS model resemble changes observed in the age-matched WT controls, including early loss of glycosaminoglycans, and decreased cartilage thickness and volume. Such changes might mimic prevalent degenerative joint diseases in the elderly. Lonafarnib monotherapy did not improve bone or cartilage parameters, but treatment combinations with pravastatin and zoledronic acid significantly improved bone structure and mechanical properties and cartilage structural parameters, which ameliorate the musculoskeletal phenotype of the disease.


Assuntos
Conservadores da Densidade Óssea/uso terapêutico , Modelos Animais de Doenças , Lamina Tipo A/genética , Progéria , Envelhecimento/efeitos dos fármacos , Envelhecimento/patologia , Animais , Osso e Ossos/efeitos dos fármacos , Osso e Ossos/patologia , Cartilagem/efeitos dos fármacos , Cartilagem/patologia , Fêmur/efeitos dos fármacos , Fêmur/patologia , Glicosaminoglicanos/análise , Articulações/efeitos dos fármacos , Articulações/patologia , Lamina Tipo A/metabolismo , Camundongos , Camundongos Transgênicos , Mutação , Osteoartrite/tratamento farmacológico , Osteoartrite/patologia , Fenótipo , Piperidinas/uso terapêutico , Pravastatina/uso terapêutico , Progéria/tratamento farmacológico , Progéria/genética , Processamento de Proteína Pós-Traducional/efeitos dos fármacos , Piridinas/uso terapêutico , Microtomografia por Raio-X , Ácido Zoledrônico/uso terapêutico
8.
Knee Surg Sports Traumatol Arthrosc ; 31(5): 1771-1780, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-35819464

RESUMO

PURPOSE: Objectives are (1) to evaluate the biomechanical effect of isolated medial patellofemoral ligament (MPFL) reconstruction in the setting of increased tibial tuberosity-trochlear groove distance (TTTG), in terms of patella contact pressures, contact area and lateral displacement; (2) to describe the threshold of TTTG up to which MPFL reconstruction should be performed alone or in combination with tibial tuberosity transfer. METHODS: A finite element model of the knee was developed and validated. The model was modified to simulate isolated MPFL reconstruction, tibial tuberosity transfer and MPFL reconstruction combined with tibial tuberosity transfer for patella malalignment. Two TT-TG distances (17 mm and 22 mm) were simulated. Patella contact pressure, contact area and lateral displacement were analysed. RESULTS: Isolated MPFL reconstruction, at early degrees of flexion, restored normal patella contact pressure when TTTG was 17 mm, but not when TTTG was 22 mm. After 60° of flexion, the TTTG distance was the main factor influencing contact pressure. Isolated MPFL reconstruction for both TTTG 17 mm and 22 mm showed higher contact area and lower lateral displacement than normal throughout knee flexion. Tibial tuberosity transfer, at early degrees of flexion, reduced the contact pressure, but did not restore the normal contact pressure. After 60° of flexion, the TTTG distance was the main factor influencing contact pressure. Tibial tuberosity transfer maintained lower contact area than normal throughout knee flexion. The lateral displacement was higher than normal between 0° and 30° of flexion (< 0.5 mm). MPFL reconstruction combined with tibial tuberosity transfer produced the same contact mechanics and kinematics of the normal condition. CONCLUSION: This study highlights the importance of considering to correct alignment in lateral tracking patella to avoid focal patella overload. Our results showed that isolated MPFL reconstruction corrects patella kinematics regardless of TTTG distance. However, isolated MPFL reconstruction would not restore normal patella contact pressure when TTTG is 22 mm. For TTTG 22 mm, the combined procedure of MPFL reconstruction and tibial tuberosity transfer provided an adequate patellofemoral contact mechanics and kinematics, restoring normal biomechanics. This data supports the use of MPFL reconstruction when the patient has normal alignment and the use of combined MPFL reconstruction and tibial tuberosity transfer in patients with elevated TT-TG distances to avoid focal overload.


Assuntos
Patela , Articulação Patelofemoral , Humanos , Patela/cirurgia , Articulação Patelofemoral/cirurgia , Articulação do Joelho/cirurgia , Tíbia/cirurgia , Ligamentos Articulares/cirurgia
9.
Sensors (Basel) ; 23(15)2023 Aug 04.
Artigo em Inglês | MEDLINE | ID: mdl-37571723

RESUMO

Monitoring shoulder kinematics, including the scapular segment, is of great relevance in the orthopaedic field. Among wearable systems, magneto-inertial measurement units (M-IMUs) represent a valid alternative for applications in unstructured environments. The aim of this systematic literature review is to report and describe the existing methods to estimate 3D scapular movements through wearable systems integrating M-IMUs. A comprehensive search of PubMed, IEEE Xplore, and Web of Science was performed, and results were included up to May 2023. A total of 14 articles was included. The results showed high heterogeneity among studies regarding calibration procedures, tasks executed, and the population. Two different techniques were described, i.e., with the x-axis aligned with the cranial edge of the scapular spine or positioned on the flat surface of the acromion with the x-axis perpendicular to the scapular spine. Sensor placement affected the scapular motion and, also, the kinematic output. Further studies should be conducted to establish a universal protocol that reduces the variability among studies. Establishing a protocol that can be carried out without difficulty or pain by patients with shoulder musculoskeletal disorders could be of great clinical relevance for patients and clinicians to monitor 3D scapular kinematics in unstructured settings or during common clinical practice.


Assuntos
Articulação do Ombro , Dispositivos Eletrônicos Vestíveis , Humanos , Fenômenos Biomecânicos , Escápula , Ombro , Amplitude de Movimento Articular
10.
J Digit Imaging ; 36(3): 869-878, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-36627518

RESUMO

The purpose of this study was to pair computed tomography (CT) imaging and machine learning for automated bone tumor segmentation and classification to aid clinicians in determining the need for biopsy. In this retrospective study (March 2005-October 2020), a dataset of 84 femur CT scans (50 females and 34 males, 20 years and older) with definitive histologic confirmation of bone lesion (71% malignant) were leveraged to perform automated tumor segmentation and classification. Our method involves a deep learning architecture that receives a DICOM slice and predicts (i) a segmentation mask over the estimated tumor region, and (ii) a corresponding class as benign or malignant. Class prediction for each case is then determined via majority voting. Statistical analysis was conducted via fivefold cross validation, with results reported as averages along with 95% confidence intervals. Despite the imbalance between benign and malignant cases in our dataset, our approach attains similar classification performances in specificity (75%) and sensitivity (79%). Average segmentation performance attains 56% Dice score and reaches up to 80% for an image slice in each scan. The proposed approach establishes the first steps in developing an automated deep learning method on bone tumor segmentation and classification from CT imaging. Our approach attains comparable quantitative performance to existing deep learning models using other imaging modalities, including X-ray. Moreover, visual analysis of bone tumor segmentation indicates that our model is capable of learning typical tumor characteristics and provides a promising direction in aiding the clinical decision process for biopsy.


Assuntos
Neoplasias Ósseas , Tomografia Computadorizada por Raios X , Masculino , Feminino , Humanos , Estudos Retrospectivos , Tomografia Computadorizada por Raios X/métodos , Aprendizado de Máquina , Neoplasias Ósseas/diagnóstico por imagem , Biópsia , Processamento de Imagem Assistida por Computador/métodos
11.
BMC Musculoskelet Disord ; 23(1): 725, 2022 Jul 29.
Artigo em Inglês | MEDLINE | ID: mdl-35906570

RESUMO

Arthrofibrosis, or rigid contracture of major articular joints, is a significant morbidity of many neurodegenerative disorders. The pathogenesis depends on the mechanism and severity of the precipitating neuromuscular disorder. Most neuromuscular disorders, whether spastic or hypotonic, culminate in decreased joint range of motion. Limited range of motion precipitates a cascade of pathophysiological changes in the muscle-tendon unit, the joint capsule, and the articular cartilage. Resulting joint contractures limit functional mobility, posing both physical and psychosocial burdens to patients, economic burdens on the healthcare system, and lost productivity to society. This article reviews the pathophysiology of arthrofibrosis in the setting of neuromuscular disorders. We describe current non-surgical and surgical interventions for treating arthrofibrosis of commonly affected joints. In addition, we preview several promising modalities under development to ameliorate arthrofibrosis non-surgically and discuss limitations in the field of arthrofibrosis secondary to neuromuscular disorders.


Assuntos
Contratura , Artropatias , Contratura/complicações , Contratura/terapia , Fibrose , Humanos , Cápsula Articular/patologia , Artropatias/etiologia , Artropatias/patologia , Artropatias/terapia , Articulações/patologia , Articulação do Joelho/cirurgia , Amplitude de Movimento Articular/fisiologia
12.
BMC Musculoskelet Disord ; 23(1): 139, 2022 Feb 11.
Artigo em Inglês | MEDLINE | ID: mdl-35148741

RESUMO

OBJECTIVE: Medial patellofemoral ligament (MPFL) injury occurs in the majority of the cases of acute patellar dislocation. The role of concomitant lateral retinaculum release with MPFL reconstruction is not clearly understood. Even though the lateral retinaculum plays a role in both medial and lateral patellofemoral joint stability in MPFL intact knees, studies have shown mixed clinical outcomes following its release during MPFL reconstruction surgery. Better understanding of the biomechanical effects of the release of the lateral retinaculum during MPFL reconstruction is warranted. We hypothesize that performing a lateral release concurrent with MPFL reconstruction will disrupt the patellofemoral joint biomechanics and result in lateral patellar instability. METHODS: A previously developed and validated finite element (FE) model of the patellofemoral joint was used to understand the effect of lateral retinaculum release following MPFL reconstruction. Contact pressure (CP), contact area (CA) and lateral patellar displacement were recorded. abstract. RESULTS: FE modeling and analysis demonstrated that lateral retinacular release following MPFL reconstruction with tibial tuberosity-tibial groove distance (TT-TG) of 12 mm resulted in a 39% decrease in CP, 44% decrease in CA and a 20% increase in lateral patellar displacement when compared to a knee with an intact MPFL. In addition, there was a 45% decrease in CP, 44% decrease in CA and a 21% increase in lateral displacement when compared to a knee that only had an MPFL reconstruction. CONCLUSION: This FE-based analysis exhibits that concomitant lateral retinaculum release with MPFL reconstruction results in decreased PF CA, CP and increased lateral patellar displacement with increased knee flexion, which may increase the risk of patellar instability.


Assuntos
Instabilidade Articular , Luxação Patelar , Articulação Patelofemoral , Humanos , Instabilidade Articular/cirurgia , Ligamentos Articulares , Patela , Luxação Patelar/diagnóstico por imagem , Luxação Patelar/cirurgia , Articulação Patelofemoral/diagnóstico por imagem , Articulação Patelofemoral/cirurgia
13.
Proc Natl Acad Sci U S A ; 116(25): 12183-12192, 2019 06 18.
Artigo em Inglês | MEDLINE | ID: mdl-31160441

RESUMO

Arthrofibrosis is a prevalent condition affecting greater than 5% of the general population and leads to a painful decrease in joint range of motion (ROM) and loss of independence due to pathologic accumulation of periarticular scar tissue. Current treatment options are limited in effectiveness and do not address the underlying cause of the condition: accumulation of fibrotic collagenous tissue. Herein, the naturally occurring peptide hormone relaxin-2 is administered for the treatment of adhesive capsulitis (frozen shoulder) and to restore glenohumeral ROM in shoulder arthrofibrosis. Recombinant human relaxin-2 down-regulates type I collagen and α smooth muscle actin production and increases intracellular cAMP concentration in human fibroblast-like synoviocytes, consistent with a mechanism of extracellular matrix degradation and remodeling. Pharmacokinetic profiling of a bolus administration into the glenohumeral joint space reveals the brief systemic and intraarticular (IA) half-lives of relaxin-2: 0.96 h and 0.62 h, respectively. Furthermore, using an established, immobilization murine model of shoulder arthrofibrosis, multiple IA injections of human relaxin-2 significantly improve ROM, returning it to baseline measurements collected before limb immobilization. This is in contrast to single IA (sIA) or multiple i.v. (mIV) injections of relaxin-2 with which the ROM remains constrained. The histological hallmarks of contracture (e.g., fibrotic adhesions and reduced joint space) are absent in the animals treated with multiple IA injections of relaxin-2 compared with the untreated control and the sIA- and mIV-treated animals. As these findings show, local delivery of relaxin-2 is an innovative treatment of shoulder arthrofibrosis.


Assuntos
Bursite/tratamento farmacológico , Relaxina/uso terapêutico , Animais , Bursite/patologia , Linhagem Celular , Colágeno/metabolismo , Modelos Animais de Doenças , Feminino , Fibrose , Humanos , Injeções Intra-Articulares , Masculino , Camundongos , Amplitude de Movimento Articular/efeitos dos fármacos , Ratos , Ratos Sprague-Dawley , Relaxina/administração & dosagem , Articulação do Ombro/efeitos dos fármacos , Articulação do Ombro/patologia
14.
Arthroscopy ; 38(3): 953-964, 2022 03.
Artigo em Inglês | MEDLINE | ID: mdl-34411682

RESUMO

PURPOSE: The purpose of this study was to develop and validate a finite element (FE) model of the patellofemoral (PF) joint to characterize patellofemoral instability, and to highlight the effect of lateral retinacular release in combination with tibial tuberosity transfer with respect to contact pressures (CP), contact area (CA), and kinematics during knee flexion. METHODS: A comprehensive, dynamic FE model of the knee joint was developed and validated through parametric comparison of PF kinematics, CP, and CA between FE simulations and in vitro, cadaveric experiments. Using this FE model, we characterized the effect of patellar instability, lateral retinacular release (LR), and tibial tuberosity transfer (TTT) in the setting of medial patellofemoral ligament injury during knee flexion. RESULTS: There was a high level of agreement in CP, CA, lateral patellar displacement, anterior patellar displacement, and superior patellar displacement between the FE model and the in vitro data (P values 0.19, 0.16, 0.81, 0.10, and 0.36, respectively). Instability conditions demonstrated the greatest CP compared to all of the other conditions. During all degrees of flexion, TTT and concomitant lateral release (TTT + LR) decreased CP significantly. TTT alone shows a consistently lower CA compared to nonrelease conditions with subsequent lateral release further decreasing CA. CONCLUSIONS: The results of this study demonstrate that the FE model described reliably simulates PF kinematics and CP within 1 SD in uncomplicated cadaveric specimens. The FE model is able to show that tibial tubercle transfer in combination with lateral retinacular release markedly decreases patellofemoral CP and CA and increases lateral patellar displacement that may decrease bony stabilization of the patella within the trochlear groove and promote lateral patellar instability. CLINICAL RELEVANCE: The goal of surgical correction for patellar instability focuses on reestablishing normal PF kinematics. By developing an FE model that can demonstrate patient PF kinematics and the results of different surgical approaches, surgeons may tailor their treatment to the best possible outcome. Of the surgical approaches that have been described, the biomechanical effects of the combination of TTT with lateral retinacular release have not been studied. Thus, the FE analysis will help shed light on the effect of the combination of TTT with lateral retinacular release on PF kinematics.


Assuntos
Instabilidade Articular , Articulação Patelofemoral , Fenômenos Biomecânicos , Cadáver , Humanos , Instabilidade Articular/cirurgia , Modelos Anatômicos , Patela/cirurgia , Articulação Patelofemoral/cirurgia , Tíbia/cirurgia
15.
Nat Mater ; 19(1): 102-108, 2020 01.
Artigo em Inglês | MEDLINE | ID: mdl-31844276

RESUMO

Early insights into the unique structure and properties of native silk suggested that ß-sheet nanocrystallites in silk would degrade prior to melting when subjected to thermal processing. Since then, canonical approaches for fabricating silk-based materials typically involve solution-derived processing methods, which have inherent limitations with respect to silk protein solubility and stability in solution, and time and cost efficiency. Here we report a thermal processing method for the direct solid-state moulding of regenerated silk into bulk 'parts' or devices with tunable mechanical properties. At elevated temperature and pressure, regenerated amorphous silk nanomaterials with ultralow ß-sheet content undergo thermal fusion via molecular rearrangement and self-assembly assisted by bound water to form a robust bulk material that retains biocompatibility, degradability and machinability. This technique reverses presumptions about the limitations of direct thermal processing of silk into a wide range of new material formats and composite materials with tailored properties and functionalities.


Assuntos
Materiais Biocompatíveis/química , Nanoestruturas/química , Seda/química , Animais , Bombyx , Força Compressiva , Feminino , Fibroínas/química , Temperatura Alta , Espectroscopia de Ressonância Magnética , Estrutura Secundária de Proteína , Ratos , Ratos Sprague-Dawley , Solubilidade , Espectroscopia de Infravermelho com Transformada de Fourier , Estresse Mecânico , Resistência à Tração , Água/química , Microtomografia por Raio-X
16.
J Bone Miner Metab ; 39(5): 893-902, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-33991260

RESUMO

INTRODUCTION: Among the various hip fracture predictors explored to date, modifiable risk factors warrant special consideration, since they present promising targets for preventative measures. This systematic review and meta-analysis aims to assess various modifiable risk factors. MATERIAL AND METHODS: We searched four online databases in September 2017. We included studies that reported on modifiable lifestyle risk factors for sustaining fragility hip fractures. The quality of the included studies was assessed using the Newcastle-Ottawa Scale (NOS). The inclusion criteria consisted of (1) adult patients with osteoporotic hip fracture, (2) original study, (3) availability of full text articles in English, and (4) report of a modifiable lifestyle risk factor. RESULTS: Thirty-five studies, containing 1,508,366 subjects in total, were included in this study. The modifiable risk factors that were significantly associated with an increased risk of hip fracture were the following: weight < 58 kg (128 lbs) (pooled OR 4.01, 95% CI 1.62-9.90), underweight body mass index (BMI) (< 18.5) (pooled OR 2.83, 95% CI 1.82-4.39), consumption of ≥ 3 cups of coffee daily (pooled OR 2.27, 95% CI 1.04-4.97), inactivity (pooled OR 2.14, 95% CI 1.21-3.77), weight loss (pooled OR 1.88, 95% CI 1.32-2.68), consumption of ≥ 27 g (approx. > 2 standard drinks) alcohol per day (pooled OR 1.54, 95% CI 1.12-2.13), and being a current smoker (pooled OR 1.50, 95% CI 1.22-1.85). Conversely, two factors were significantly associated with a decreased risk of hip fracture: obese BMI (> 30) (pooled OR 0.58, 95% CI 0.34-0.99) and habitual tea drinking (pooled OR 0.72, 95% CI 0.66-0.80). CONCLUSION: Modifiable factors may be utilized clinically to provide more effective lifestyle interventions for at risk populations. We found that low weight and underweight BMI carried the highest risk, followed by high coffee consumption, inactivity, weight loss, and high daily alcohol consumption.


Assuntos
Fraturas do Quadril , Fraturas por Osteoporose , Adulto , Índice de Massa Corporal , Fraturas do Quadril/epidemiologia , Humanos , Estilo de Vida , Fraturas por Osteoporose/epidemiologia , Fatores de Risco
17.
BMC Musculoskelet Disord ; 22(1): 637, 2021 Jul 24.
Artigo em Inglês | MEDLINE | ID: mdl-34303366

RESUMO

BACKGROUND: The purpose of this systematic review and meta-analysis is to compare the conservative and accelerated rehabilitation protocols in patients who underwent arthroscopic rotator cuff repair in terms of clinical outcomes and range of motions at 3, 6, 12, and 24-month follow-up. METHODS: According to PRISMA guidelines, a systematic review of the literature was performed. For each included article, the following data has been extracted: authors, year, study design, level of evidence, demographic characteristics, follow-up, clinical outcomes, range of motions, and retear events. A meta-analysis was performed to compare accelerated versus conservative rehabilitation protocols after arthroscopic rotator cuff repair. The retear rate, postoperative Constant-Murley score and range of motions at 3, 6, 12, and 24 months of follow-up were the outcomes measured. RESULTS: The search strategy yielded 16 level I-II clinical studies. A total of 1424 patients, with 732 patients and 692 in the accelerated and conservative group, were included. The average age (mean ± standard deviation) was 56.1 ± 8.7 and 56.6 ± 9 in the accelerated and conservative group. The mean follow-up was 12.5 months, ranging from 2 to 24 months. The meta-analysis showed no statistically significant differences in terms of retear rate between the groups (P = 0.29). The superiority of the accelerated group was demonstrated in terms of external rotation (P < 0.05) at 3-month follow-up; in terms of forward elevation, external rotation, abduction (P < 0.05), but not in terms of Constant-Murley score at 6-month follow-up; in terms of forward elevation (P < 0.05) at 12-month follow-up. No significant differences between the two group were highlighted at 24-month follow-up. CONCLUSIONS: No statistically significant differences in the retear rate among the accelerated and conservative group have been demonstrated. On the other hand, statistically and clinically significant differences were found in terms of external rotation at 3 and 6 months of follow-up in favour of the accelerated group. However, no differences between the two groups were detected at 24 months follow-up.


Assuntos
Lesões do Manguito Rotador , Manguito Rotador , Artroscopia , Humanos , Amplitude de Movimento Articular , Manguito Rotador/cirurgia , Lesões do Manguito Rotador/diagnóstico , Lesões do Manguito Rotador/cirurgia , Resultado do Tratamento
18.
BMC Musculoskelet Disord ; 22(1): 625, 2021 Jul 15.
Artigo em Inglês | MEDLINE | ID: mdl-34266442

RESUMO

BACKGROUND: Knowledge regarding the biomechanics of the meniscus has grown exponentially throughout the last four decades. Numerous studies have helped develop this knowledge, but these studies have varied widely in their approach to analyzing the meniscus. As one of the subcategories of mechanical phenomena Medical Subject Headings (MeSH) terms, mechanical stress was introduced in 1973. This study aims to provide an up-to-date chronological overview and highlights the evolutionary comprehension and understanding of meniscus biomechanics over the past forty years. METHODS: A literature review was conducted in April 2021 through PubMed. As a result, fifty-seven papers were chosen for this narrative review and divided into categories; Cadaveric, Finite element (FE) modeling, and Kinematic studies. RESULTS: Investigations in the 1970s and 1980s focused primarily on cadaveric biomechanics. These studies have generated the fundamental knowledge basis for the emergence of FE model studies in the 1990s. As FE model studies started to show comparable results to the gold standard cadaveric models in the 2000s, the need for understanding changes in tissue stress during various movements triggered the start of cadaveric and FE model studies on kinematics. CONCLUSION: This study focuses on a chronological examination of studies on meniscus biomechanics in order to introduce concepts, theories, methods, and developments achieved over the past 40 years and also to identify the likely direction for future research. The biomechanics of intact meniscus and various types of meniscal tears has been broadly studied. Nevertheless, the biomechanics of meniscal tears, meniscectomy, or repairs in the knee with other concurrent problems such as torn cruciate ligaments or genu-valgum or genu-varum have not been extensively studied.


Assuntos
Menisco , Lesões do Menisco Tibial , Fenômenos Biomecânicos , Humanos , Meniscectomia , Meniscos Tibiais
19.
BMC Musculoskelet Disord ; 22(1): 512, 2021 Jun 04.
Artigo em Inglês | MEDLINE | ID: mdl-34088275

RESUMO

BACKGROUND: Nonunion following treatment of supracondylar femur fractures with lateral locked plates (LLP) has been reported to be as high as 21 %. Implant related and surgeon-controlled variables have been postulated to contribute to nonunion by modulating fracture-fixation construct stiffness. The purpose of this study is to evaluate the effect of surgeon-controlled factors on stiffness when treating supracondylar femur fractures with LLPs: 1. Does plate length affect construct stiffness given the same plate material, fracture working length and type of screws? 2. Does screw type (bicortical locking versus bicortical nonlocking or unicortical locking) and number of screws affect construct stiffness given the same material, fracture working length, and plate length? 3. Does fracture working length affect construct stiffness given the same plate material, length and type of screws? 4. Does plate material (titanium versus stainless steel) affect construct stiffness given the same fracture working length, plate length, type and number of screws? METHODS: Mechanical study of simulated supracondylar femur fractures treated with LLPs of varying lengths, screw types, fractureworking lenghts, and plate/screw material. Overall construct stiffness was evaluated using an Instron hydraulic testing apparatus. RESULTS: Stiffness was 15 % higher comparing 13-hole to the 5-hole plates (995 N/mm849N vs. /mm, p = 0.003). The use of bicortical nonlocking screws decreased overall construct stiffness by 18 % compared to bicortical locking screws (808 N/mm vs. 995 N/mm, p = 0.0001). The type of screw (unicortical locking vs. bicortical locking) and the number of screws in the diaphysis (3 vs. 10) did not appear to significantly influence construct stiffness (p = 0.76, p = 0.24). Similarly, fracture working length (5.4 cm vs. 9.4 cm, p = 0.24), and implant type (titanium vs. stainless steel, p = 0.12) did also not appear to effect stiffness. DISCUSSION: Using shorter plates and using bicortical nonlocking screws (vs. bicortical locking screws) reduced overall construct stiffness. Using more screws, using unicortical locking screws, increasing fracture working length and varying plate material (titanium vs. stainless steel) does not appear to significantly alter construct stiffness. Surgeons can adjust plate length and screw types to affect overall fracture-fixation construct stiffness; however, the optimal stiffness to promote healing remains unknown.


Assuntos
Fraturas do Fêmur , Cirurgiões , Fenômenos Biomecânicos , Parafusos Ósseos , Fraturas do Fêmur/diagnóstico por imagem , Fraturas do Fêmur/cirurgia , Fixação Interna de Fraturas/efeitos adversos , Humanos
20.
Calcif Tissue Int ; 107(1): 1-9, 2020 07.
Artigo em Inglês | MEDLINE | ID: mdl-32253446

RESUMO

Fragility hip fractures and their associated morbidity and mortality pose a global healthcare problem. Several pharmaceutical products have been postulated to alter bone architecture and contribute to fragility hip fractures. We searched four electronic databases from inception to September 2017. Inclusion criteria were the following: (1) adult patients with fragility hip fractures, (2) full text in English, (3) minimum one-year follow-up, and (4) reporting of at least one risk factor. To minimize heterogeneity among the studies, we performed subgroup analyses. Whenever heterogeneity remained significant, we employed random effect meta-analysis for data pooling. Thirty-eight studies were included, containing 1,244,155 subjects and 188,966 cases of fragility hip fractures. Following medications were significantly associated with fragility hip fractures: Antidepressants (OR 2.07, 95% CI 1.98-2.17), antiparkinsonian drugs (OR 2.21, 95% CI 1.15-4.24), antipsychotic drugs (OR 2.0, 95% CI 1.50-2.66), anxiolytic drugs (OR 1.44, 95% CI 1.19-1.75), benzodiazepines (OR 1.84, 95% CI 1.26-2.69), sedatives (OR 1.33, 95% CI 1.14-1.54), systemic corticosteroids (OR 1.65, 95% CI 1.37-1.99), H2 antagonists (OR 1.21, 95% CI 1.18-1.24), proton pump inhibitors (OR 1.41, 95% CI 1.16-1.71), and thyroid hormone (OR 1.29, 95% CI 1.13-1.47). Hormone replacement therapy with estrogen (HRT) was associated with decreased risk of hip fracture (OR 0.80, 95% CI 0.65-0.98). There are several medications associated with sustaining a fragility hip fracture. Medical interventions should be considered for patients on these medications, including information about osteoporosis and fracture prevention.


Assuntos
Efeitos Colaterais e Reações Adversas Relacionados a Medicamentos , Fraturas do Quadril , Fraturas por Osteoporose , Adulto , Fraturas do Quadril/induzido quimicamente , Humanos , Fraturas por Osteoporose/induzido quimicamente , Preparações Farmacêuticas , Fatores de Risco
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa