RESUMO
BACKGROUND: Pocket hematoma is the most prevalent complication with cardiac implantable electronic devices (CIEDs), especially in patients who are undergoing oral anticoagulation and/or antiplatelet therapy. OBJECTIVE: To evaluate the efficacy of hypothermic compression bandaging versus conventional compression bandaging for the prevention of surgical wound hematoma of CIEDs in patients who are undergoing chronic anticoagulant drug use and/or antiplatelet therapy. METHODS: This was a single-center randomized prospective study. The intervention group received a hypothermic compression bandage, and the control group received a conventional compression bandage. The primary endpoint was the appearance of hematoma 10 days after the intervention. RESULTS: A total of 310 patients participated in the study. The mean age of the participants was 73.77 ± 10.68 years, and 74.8% were men. In the intervention group, 5.88% (n = 18) of patients developed ecchymosis, and 1.3% (n = 4) developed mild hematoma. In the control group, 5.88% (n = 18) of patients developed ecchymosis, and 2.9% (n = 9) developed mild hematoma. No patient in either group had a severe hematoma. No significant differences were observed between the two types of dressing in any of the three degrees of hematoma. CONCLUSIONS: This study demonstrated that compression bandaging with or without hypothermic therapy effectively prevents pocket hematoma of CIEDs in patients at high risk of bleeding.
Assuntos
Bandagens Compressivas , Humanos , Masculino , Feminino , Idoso , Estudos Prospectivos , Pessoa de Meia-Idade , Hematoma/prevenção & controle , Hematoma/etiologia , Idoso de 80 Anos ou mais , Ferida Cirúrgica/terapia , Ferida Cirúrgica/complicações , Hipotermia Induzida/métodos , Hipotermia Induzida/instrumentação , Hipotermia Induzida/efeitos adversos , Desfibriladores Implantáveis/efeitos adversos , Marca-Passo Artificial/efeitos adversos , Resultado do TratamentoRESUMO
AIMS: To define a stepwise application of left bundle branch pacing (LBBP) criteria that will simplify implantation and guarantee electrical resynchronization. Left bundle branch pacing has emerged as an alternative to biventricular pacing. However, a systematic stepwise criterion to ensure electrical resynchronization is lacking. METHODS AND RESULTS: A cohort of 24 patients from the LEVEL-AT trial (NCT04054895) who received LBBP and had electrocardiographic imaging (ECGI) at 45 days post-implant were included. The usefulness of ECG- and electrogram-based criteria to predict accurate electrical resynchronization with LBBP were analyzed. A two-step approach was developed. The gold standard used to confirm resynchronization was the change in ventricular activation pattern and shortening in left ventricular activation time, assessed by ECGI. Twenty-two (91.6%) patients showed electrical resynchronization on ECGI. All patients fulfilled pre-screwing requisites: lead in septal position in left-oblique projection and W paced morphology in V1. In the first step, presence of either right bundle branch conduction delay pattern (qR or rSR in V1) or left bundle branch capture Plus (QRS ≤120â ms) resulted in 95% sensitivity and 100% specificity to predict LBBP resynchronization, with an accuracy of 95.8%. In the second step, the presence of selective capture (100% specificity, only 41% sensitivity) or a spike-R <80â ms in non-selective capture (100% specificity, sensitivity 46%) ensured 100% accuracy to predict resynchronization with LBBP. CONCLUSION: Stepwise application of ECG and electrogram criteria may provide an accurate assessment of electrical resynchronization with LBBP (Graphical abstract).
Assuntos
Fascículo Atrioventricular , Terapia de Ressincronização Cardíaca , Humanos , Bloqueio de Ramo/diagnóstico , Bloqueio de Ramo/terapia , Estimulação Cardíaca Artificial/métodos , Terapia de Ressincronização Cardíaca/métodos , Eletrocardiografia/métodos , Sistema de Condução Cardíaco , Resultado do TratamentoRESUMO
BACKGROUND: It is unknown whether His-Purkinje conduction system pacing (HPCSP), as either His bundle or left bundle branch pacing, could be an alternative to cardiac resynchronization therapy (BiVCRT) for patients with left ventricular dysfunction needing ventricular pacing due to atrioventricular block. The aim of the study is to compare the echocardiographic response and clinical improvement between HPCSP and BiVCRT. METHODS: Consecutive patients who successfully received HPCSP were compared with a historical cohort of BiVCRT patients. Patients were 1:1 matched by age, LVEF, atrial fibrillation, renal function and cardiomyopathy type. Responders were defined as patients who survived, did not require heart transplantation and increased LVEF ≥5 points at 6-month follow-up. RESULTS: HPCSP was successfully achieved in 92.5% (25/27) of patients. During follow-up, 8% (2/25) of HPCSP patients died and 4% (1/25) received a heart transplant, whereas 4% (1/25) of those in the BiVCRT cohort died. LVEF improvement was 10% ± 8% HPCSP versus 7% ± 5% BiVCRT (p = .24), and the percentage of responders was 76% (19/25) HPCSP versus 64% (16/25) BiVCRT (p = .33). Among survivors, the percentage of patients who improved from baseline II-IV mitral regurgitation (MR) to 0-I MR was 9/11 (82%) versus 2/8 (25%) (p = .02). Compared to those with BiVCRT, patients with HPCSP achieved better NYHA improvement: 1 point versus 0.5 (OR 0.34; p = .02). CONCLUSION: HPCSP in patients with LVEF ≤45% and atrioventricular block improved the LVEF and induced a response similar to that of BiVCRT. HPCSP significantly improved MR and NYHA functional class. HPCSP may be an alternative to BiVCRT in these patients. (Figure 1. Central Illustration). [Figure: see text].
Assuntos
Bloqueio Atrioventricular , Terapia de Ressincronização Cardíaca , Insuficiência Cardíaca , Disfunção Ventricular , Fascículo Atrioventricular , Doença do Sistema de Condução Cardíaco , Estimulação Cardíaca Artificial/efeitos adversos , Terapia de Ressincronização Cardíaca/efeitos adversos , Insuficiência Cardíaca/terapia , Humanos , Volume Sistólico , Resultado do Tratamento , Disfunção Ventricular/etiologia , Disfunção Ventricular/terapia , Função Ventricular EsquerdaRESUMO
BACKGROUND: His-Purkinje conduction system pacing (HPCSP) has been proposed as an alternative to Cardiac Resynchronization Therapy (CRT); however, predictors of echocardiographic response have not been described in this population. Septal flash (SF), a fast contraction and relaxation of the septum, is a marker of intraventricular dyssynchrony. METHODS: The study aimed to analyze whether HPCSP corrects SF in patients with CRT indication, and if correction of SF predicts echocardiographic response. This retrospective analysis of prospectively collected data included 30 patients. Left ventricular ejection fraction (LVEF) was measured with echocardiography at baseline and at 6-month follow-up. Echocardiographic response was defined as increase in five points in LVEF. RESULTS: HPCSP shortened QRS duration by 48 ± 21 ms and SF was significantly decreased (baseline 3.6 ± 2.2 mm vs. HPCSP 1.5 ± 1.5 mm p < .0001). At 6-month follow-up, mean LVEF improvement was 8.6% ± 8.7% and 64% of patients were responders. There was a significant correlation between SF correction and increased LVEF (r = .61, p = .004). A correction of ≥1.5 mm (baseline SF - paced SF) had a sensitivity of 81% and 80% specificity to predict echocardiographic response (area under the curve 0.856, p = .019). CONCLUSION: HPCSP improves intraventricular dyssynchrony and results in 64% echocardiographic responders at 6-month follow-up. Dyssynchrony improvement with SF correction may predict echocardiographic response at 6-month follow-up.
Assuntos
Terapia de Ressincronização Cardíaca , Insuficiência Cardíaca , Disfunção Ventricular Esquerda , Estimulação Cardíaca Artificial , Terapia de Ressincronização Cardíaca/métodos , Ecocardiografia , Insuficiência Cardíaca/terapia , Ventrículos do Coração , Humanos , Estudos Retrospectivos , Volume Sistólico/fisiologia , Resultado do Tratamento , Disfunção Ventricular Esquerda/prevenção & controle , Função Ventricular EsquerdaRESUMO
AIMS: Riata® implantable cardioverter-defibrillator (ICD) leads from St. Jude Medical are prone to malfunction. This study aimed to describe the rate of this lead's malfunction in a very long-term follow-up. METHODS: This single-centre observational study included 50 patients who received a Riata 7Fr dual-coil lead between 2003 and 2008. Follow-up was conducted both in person and remotely, and analysed at 8-month intervals. We evaluated the rates of cable externalization (CE), electrical failure (EF), and the interaction of these two complications. Structural lead failure was defined as radiographic CE. Oversensing of non-cardiac signal or sudden changes in impedance, sensing, or pacing thresholds constituted EF. RESULTS: During a mean follow-up of 10.2⯱â¯2.9 years, 16 patients (32%) died. We observed lead malfunction in 13 patients (26%): three (23%) due to CE, six (46%) to EF and four (31%) to both complications. Of the malfunctioning leads, 77% failed after seven years of follow-up. The incidence rate (IR) of overall malfunction per 100 patients per year was 0.9 during the first seven years post-implantation, increased to 7.0 after the 7th year and more than doubled (to 16.7) after 10 years. Beyond seven years post-implantation, IR per 100 patient-years increased in both EF and CE (from 0.6 to 5.6 vs. 0.3 to 4.2, respectively). Presence of CE was associated with a 4-fold increase in the proportion of EF. CONCLUSION: The incidence of Riata ICD lead malfunction, both for EF and CE, increased dramatically after seven years and then more than doubled after 10 years post-implantation.
RESUMO
AIMS: Longitudinal dyssynchrony correction and 'strain' improvement by comparable cardiac resynchronization therapy (CRT) techniques is unreported. Our purpose was to compare echocardiographic dyssynchrony correction and 'strain' improvement by conduction system pacing (CSP) vs. biventricular pacing (BiVP) as a marker of contractility improvement during 1-year follow-up. METHODS AND RESULTS: A treatment-received analysis was performed in patients included in the LEVEL-AT trial (NCT04054895), randomized to CSP or BiVP, and evaluated at baseline (ON and OFF programming) and at 6 and 12â months (n = 69, 32% women). Analysis included intraventricular (septal flash), interventricular (difference between left and right ventricular outflow times), and atrioventricular (diastolic filling time) dyssynchrony and 'strain' parameters [septal rebound, global longitudinal 'strain' (GLS), LBBB pattern, and mechanical dispersion). Baseline left ventricular ejection fraction (LVEF) was 27.5 ± 7%, and LV end-systolic volume (LVESV) was 138 ± 77â mL, without differences between groups. Longitudinal analysis showed LVEF and LVESV improvement (P < 0.001), without between-group differences. At 12-month follow-up, adjusted mean LVEF was 46% with CSP (95% CI 42.2 and 49.3%) vs. 43% with BiVP (95% CI 39.6 and 45.8%), (P = 0.31), and LVESV was 80â mL (95% CI 55.3 and 104.5â mL) vs. 100â mL (95% CI 78.7 and 121.6â mL), respectively (P = 0.66). Longitudinal analysis showed a significant improvement of all dyssynchrony parameters and GLS over time (P < 0.001), without differences between groups. Baseline GLS significantly correlated with LVEF and LVESV at 12-month follow-up. CONCLUSION: CSP and BiVP provided similar dyssynchrony and 'strain' correction over time. Baseline global longitudinal 'strain' predicted ventricular remodelling at 12-month follow-up.
Assuntos
Terapia de Ressincronização Cardíaca , Humanos , Feminino , Masculino , Terapia de Ressincronização Cardíaca/métodos , Idoso , Pessoa de Meia-Idade , Resultado do Tratamento , Ecocardiografia , Insuficiência Cardíaca/terapia , Insuficiência Cardíaca/fisiopatologia , Insuficiência Cardíaca/diagnóstico por imagem , Volume Sistólico/fisiologia , Disfunção Ventricular Esquerda/diagnóstico por imagem , Disfunção Ventricular Esquerda/terapia , Disfunção Ventricular Esquerda/fisiopatologia , Estudos Longitudinais , SeguimentosRESUMO
BACKGROUND: Left bundle branch pacing (LBBP) is considered an alternative to cardiac resynchronization therapy (CRT). However, LBBP is not suitable for all patients with heart failure. OBJECTIVE: The aim of our study was to identify predictors of unsuccessful LBBP implantation in CRT candidates. METHODS: A cohort of consecutive patients with indications for CRT were included. Clinical, echocardiographic, and electrocardiographic variables were prospectively recorded. RESULTS: A total of 187 patients were included in the analysis. LBBP implantation was successful in 152 of 187 patients (81.2%) and failed in 35 of 187 patients (18.7%). The causes of unsuccessful implantation were unsatisfactory paced QRS morphology (28 of 35 [80%]), inability to screw the helix (4 of 35 [11.4%]), lead instability (2 of 35 [5.7%]), and high pacing thresholds (1 of 35 [2.8%]). The left ventricular end-diastolic diameter (LVEDD), non-LBBB (left bundle branch block) QRS morphology, and QRS width were predictors of failed implantation according to the univariate analysis. According to the multivariate regression analysis, LVEDD (odds ratio 1.31 per 5-mm increase; 95% confidence interval 1.05-1.63 per 5-mm increase; P = .02) and non-LBBB (odds ratio 3.07; 95% confidence interval 1.08-8.72; P = .03) were found to be independent predictors of unsuccessful LBBP implantation. An LVEDD of 60 mm has 60% sensitivity and 71% specificity for predicting LBBP implant failure. CONCLUSION: When LBBP was used as CRT, LVEDD and non-LBBB QRS morphology predicted unsuccessful implantation. Non-LBBB triples the likelihood of failed implantation independent of LVEDD. Caution should be taken when considering these parameters to plan the best pacing strategy for patients.
RESUMO
BACKGROUND: Conduction system pacing (CSP) has emerged as an alternative to biventricular pacing (BiVP). Randomized studies comparing both therapies are scarce and do not include left bundle branch pacing. OBJECTIVES: This study aims to compare ventricular resynchronization achieved by CSP vs BiVP in patients with cardiac resynchronization therapy indication. METHODS: LEVEL-AT (Left Ventricular Activation Time Shortening with Conduction System Pacing vs Biventricular Resynchronization Therapy) was a randomized, parallel, controlled, noninferiority trial. Seventy patients with cardiac resynchronization therapy indication were randomized 1:1 to BiVP or CSP, and followed up for 6 months. Crossover was allowed when primary allocation procedure failed. Primary endpoint was the change in left ventricular activation time, measured using electrocardiographic imaging. Secondary endpoints were left ventricular reverse remodeling and the combined endpoint of heart failure hospitalization or death at 6-month follow-up. RESULTS: Thirty-five patients were allocated to each group. Eight (23%) patients crossed over from CSP to BiVP; 2 patients (6%) crossed over from BiVP to CSP. Electrocardiographic imaging could not be performed in 2 patients in each group. A similar decrease in left ventricular activation time was achieved by CSP and BiVP (-28 ± 26 ms vs -21 ± 20 ms, respectively; mean difference -6.8 ms; 95% CI: -18.3 ms to 4.6 ms; P < 0.001 for noninferiority). Both groups showed a similar change in left ventricular end-systolic volume (-37 ± 59 mL CSP vs -30 ± 41 mL BiVP; mean difference: -8 mL; 95% CI: -33 mL to 17 mL; P = 0.04 for noninferiority) and similar rates of mortality or heart failure hospitalizations (2.9% vs 11.4%, respectively) (P = 0.002 for noninferiority). CONCLUSIONS: Similar degrees of cardiac resynchronization, ventricular reverse remodeling, and clinical outcomes were attained by CSP as compared to BiVP. CSP could be a feasible alternative to BiVP. (LEVEL-AT [Left Ventricular Activation Time Shortening With Conduction System Pacing vs Biventricular Resynchronization Therapy]; NCT04054895).
Assuntos
Terapia de Ressincronização Cardíaca , Insuficiência Cardíaca , Humanos , Terapia de Ressincronização Cardíaca/métodos , Sistema de Condução Cardíaco , Bloqueio de Ramo , Doença do Sistema de Condução Cardíaco/terapia , Remodelação VentricularRESUMO
BACKGROUND: The Micra transcatheter pacing system (Micra TPS) is often implanted in patients with atrial fibrillation and thus with increased thromboembolic risk. It is unknown whether the use of anticoagulants, associated with the use of a large venous introducer, implies an increased risk of bleeding in this group of patients. OBJECTIVE: The purpose of this study was to assess the incidence of bleeding and thromboembolic complications after Micra TPS implantation with and without therapeutic anticoagulation. METHODS: This single-center observational study included 107 consecutive patients receiving the Micra TPS from 2014 to 2018. At procedure completion, a figure-of-eight suture was placed at the femoral puncture site after sheath withdrawal and was maintained for 24 hours. In patients receiving enoxaparin or new oral anticoagulants, treatment was discontinued 12 or 24 hours before the procedure, respectively, and was reinitiated 4-6 hours postprocedure. In those receiving vitamin K antagonists (VKAs), dosing was not discontinued and the procedure was performed if the international normalized ratio was less than 3. RESULTS: Sixty-four patients (60%) did not receive anticoagulants. Of the 43 (40%) who did, 29 (67%) received VKAs, 8 (19%) received new oral anticoagulants, and 6 (14%) received enoxaparin. Two patients presented hemorrhagic or thromboembolic complications during short-term follow-up: 1 woman receiving VKAs presented hemorrhagic pericardial effusion without tamponade and 1 woman not receiving anticoagulants presented thrombosis of the ipsilateral saphenous vein. CONCLUSION: Bleeding and thromboembolic complications after receiving Micra TPSs are infrequent. The use of anticoagulant therapy, regardless of the type, does not increase the complications associated with the procedure.