Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Opt Express ; 21(23): 28849-55, 2013 Nov 18.
Artigo em Inglês | MEDLINE | ID: mdl-24514398

RESUMO

We report the design and use of a megawatt peak power Nd:YAG/Cr4+:YAG microchip laser for efficient second to ninth harmonic generation. We show that the sub-nanosecond pulse width region, between 100 ps and 1 ns, is ideally suited for efficient wavelength conversion. Using this feature, we report 85% second harmonic generation efficiency using lithium triborate (LBO), 60% fourth harmonic generation efficiency usingß-barium borate, and 44% IR to UV third harmonic generation efficiency using Type I and Type II LBO. Finally, we report the first demonstration of 118 nm VUV generation in xenon gas using a microchip laser.

2.
Toxicol In Vitro ; 13(1): 139-51, 1999 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-20654472

RESUMO

Skin(2TM) ZK1100 (ZK1100) assay and tissue equivalent assay (TEA, Skin(2TM) ZK1200) are human dermal models. These assays were evaluated as alternatives to the Draize eye irritation test (Draize test) in rabbits. Thirty-nine cosmetic ingredients were selected and used as test substances. The ZK1100 assay was conducted according to an original protocol provided by Advanced Tissue Sciences, a kit supplier. The TEA assay followed a protocol developed by Osborne et al., (1995a). Coefficients of variation (CV) ranged from 11.7 to 133 in results from the ZK1100 assay; three test substances showed the CVs more than 100. These were cetyltrimethylammonium chloride (S3-7), domiphen bromide (S3-11) and di(2-ethylhexyl) sodium sulfosuccinate (S3-14). Acid Red 92 (S2-3) was excluded from data analysis because its absorbance interfered with the endpoint of ZK1100 assay. The CVs from the TEA assay ranged from 31.8 to 119; two test substances showed the CVs more than 100. These were acetic acid and glycolic acid (S3-13). Butanol (S3-9) was excluded from the analysis because it was assumed to volatilize during a sample preparation. Pearson's coefficient of correlation with maximum average Draize total score (MAS) and 24hr score from the Draize tests were -0.71 and -0.72 for the ZK1100 results and -0.63 and -0.60 for the TEA results. When a MAS of 15 was set as a breakpoint for the classification of eye irritancy on Cooper's plots comparing the in vitro and the Draize data, the ZK1100 results showed five false positives and four false negatives; the TEA results showed three false positives and no false negatives.

SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa