Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Int Ophthalmol ; 44(1): 151, 2024 Mar 20.
Artigo em Inglês | MEDLINE | ID: mdl-38507136

RESUMO

PURPOSE: To identify the rate and characteristics of cataract surgery candidates suitable for multifocal intraocular lens implantation among patients undergoing preoperative evaluation in a public hospital. MATERIALS AND METHODS: Screening was performed based on the patient's medical records, comprehensive ophthalmic examination, optical biometry (Zeiss, IOL Master 700) and optical coherence tomography (OCT) (Heidelberg, OCT Spectralis) in accordance with the relevant indications and contraindications mentioned in the pertinent literature. Patients were included in the present study if they were eligible for bilateral cataract surgery. The exclusion criteria were the presence of central nervous system or motility issues, prior refractive surgery, the presence of astigmatism greater than 1 dioptre and/or the presence of important ocular comorbidities in either eye. RESULTS: The study evaluated 1200 consecutive patients. Four hundred thirty-two patients (36%) were not eligible for bilateral surgery and were excluded from the study. Of the 768 patients included in the present study, 346 (45.1%) were considered suitable candidates. Four hundred twenty-two patients (54.9%) were excluded for one or both eyes. Among them, 121 (28.7%) were excluded because of retinal disease, 120 (28.4%) because of regular astigmatism (> 1.0 D of corneal astigmatism), 32 (7.5%) because of pseudoexfoliation or zonular instability, and 30 (7.1%) because of glaucoma or ocular hypertension; in addition, 90 (21.3%) patients were excluded for multiple reasons. Suitable candidates were significantly younger (70 and 75 years, respectively) (p < 0.001). After being informed about the potential risks and benefits of MOIL implantation, 212 of 346 (83.8%) eligible patients provided consent. CONCLUSION: Close to half of cataract patients in a public hospital were eligible for MOIL implantation, and the majority of patients would proceed to surgery. The most prevalent contraindication was macular disease.


Assuntos
Astigmatismo , Catarata , Lentes Intraoculares , Facoemulsificação , Humanos , Implante de Lente Intraocular/métodos , Lentes Intraoculares/efeitos adversos , Acuidade Visual , Facoemulsificação/métodos , Catarata/complicações , Catarata/epidemiologia , Refração Ocular
2.
Saudi J Ophthalmol ; 36(2): 229-236, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36211320

RESUMO

PURPOSE: The purpose of the study is to evaluate the comparability of corneal power measurements, anterior chamber depth (ACD), and white-to-white (WTW) distance between a high-resolution Scheimpflug-based tomography (Pentacam HR; Oculus GmbH, Wetzlar, Germany) and a swept-source optical biometry, IOL Master 700; Carl Zeiss Meditec AG, Jena, Germany) in patients having undergone a myopic refractive surgery. METHODS: This prospective, interinstrument reliability analysis included 31 individuals with a previous myopic laser refractive correction. Standard keratometry and total keratometry (TK) of the flattest and steepest axis of the IOL Master 700 were compared with standard keratometry (simulated keratometry [SimK]), true net power (TNP), equivalent keratometer readings (EKR), and total corneal refractive power of the Pentacam. The Bland-Altman analysis evaluated the agreement between the measurements of both devices. A paired t-test was performed to compare the mean values of the variables obtained by the two devices. RESULTS: Mean age of the participants was 31.87 ± 13.17 years. Ten patients (32.3%) had undergone laser in situ keratomileusis surgery, and 21 (67.7%) had undergone photorefractive keratectomy surgery. The two devices generated statistically significant differences in almost all the comparisons between their corneal keratometry values, ACD, and WTW. The two devices agreed in some of the flat axis values and more specifically on SimK1 and K1, EKR K1 along 1 mm-zone and K1, as well as on the comparison between the EKR keratometry values along 1, 2, and 3 mm-zone with their corresponding TKs. CONCLUSION: IOL Master 700 and Pentacam HR do not show good concordance and cannot be used interchangeably when measuring keratometry values in postrefractive eyes, rendering the IOL power calculation in postrefractive eyes really challenging.

3.
Ther Adv Ophthalmol ; 14: 25158414211063283, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35387236

RESUMO

Background: Cataract surgery in keratoconic patients is challenging because of the corneal distortion, which can lead to inaccurate keratometry readings. This study is a comparison of the accuracy of keratometry readings by two types of devices in a tertiary hospital. Purpose: To evaluate the comparability of corneal power measurements, anterior chamber depth (ACD), and white-to-white (WTW) distance between Scheimpflug-based tomography (Pentacam AXL; OCULUS GmbH, Wetzlar, Germany) and swept-source optical biometry (IOLMaster 700; Carl Zeiss Meditec AG, Jena, Germany) in patients with keratoconus. Methods: This pilot, prospective, interinstrument reliability study included 30 keratoconic eyes of 15 individuals who had not undergone any kind of corneal surgery. Standard K and total refractive power (TK®) of the flattest and steepest axes of the IOLMaster 700 were compared with the standard keratometry (SimK), true net power (TNP), equivalent keratometer readings (EKR), and total corneal refractive power (TCRP) of the Pentacam. The Bland-Altman analysis was used to evaluate the agreement between the measurements of both devices. The paired-samples t-test and the Wilcoxon signed-rank test were performed to compare the mean values of the variables obtained with the devices. Results: The K1 value of the IOLMaster 700 was significantly higher from EKR K1 along the 3-mm (mean difference: 0.79 diopters, p = 0.01), 4-mm (mean difference: 1.01 D, p = 0.01), and 4.5-mm zones (mean difference: 1.20 D, p = 0.01) and TNP K1 along the 3-mm (mean difference: 0.88 D, p < 0.001) and 4-mm zones (mean difference: 0.97 D, p < 0.001). The TK1 value was significantly higher from EKR K1 along the 2-mm (mean difference: 0.42 D, p = 0.04), 3-mm (mean difference: 0.83 D, p = 0.003), 4-mm (mean difference: 1.05 D, p = 0.004), and 4.5-mm zones (mean difference: 1.24 D, p = 0.005) and TNP K1 along the 3-mm (mean difference: 0.92 D, p < 0.001) and 4-mm zones (mean difference: 1.01 D, p < 0.001). The K2 value of the IOLMaster 700 was significantly higher from TK2 (mean difference: 0.11 D, p = 0.04) and all the corresponding variables of the Pentacam device. The TK2 value was significantly higher from all the corresponding variables of the Pentacam device. The Pentacam also yielded significantly lower values for the WTW distance (mean difference: 0.31 mm, p < 0.001) and no significant difference in terms of ACD values (p = 0.9). Conclusion: The IOLMaster measured significantly greater keratometry readings in the steep axis for all the variables studied. The keratometry and WTW measurements of the investigated devices cannot be used interchangeably in keratoconus.

4.
Cornea ; 41(1): 60-68, 2022 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-33797466

RESUMO

PURPOSE: To investigate correlations between specular microscopy endothelial parameters and age with corneal densitometry values, as they are presented from a Scheimpflug device, in different levels of the cornea. METHODS: Two hundred eighty-four eyes of 142 healthy subjects were included in this observational, prospective study. Corneal densitometry was evaluated with Scheimpflug imaging system in the central 0- to 2-mm annular zone of the cornea, whereas the endothelial cell properties were assessed with the use of a noncontact specular microscope. RESULTS: Corneal densitometry values of all corneal layers were statistically significant and positively correlated with age. In univariate linear regression analysis among corneal densitometry values and the endothelial parameters, only endothelial cell density (CD) was statistically significant and inversely correlated with densitometry values in all corneal layers. In stepwise multivariate linear regression analysis, after adjustment for age, hexagonality was statistically significant and inversely correlated with posterior densitometry values, whereas coefficient of variation was positively and significantly correlated with the anterior densitometry values. When repeating stepwise multivariate linear regression analysis without adjusting for age, CD was negatively and significantly correlated with corneal densitometry values of all layers, whereas coefficient of variation was positively and significantly correlated with anterior and total corneal densitometry values. CONCLUSIONS: Corneal densitometry increases with age. It is also inversely correlated with CD, and this might be used as an indirect way to assess the status of the corneal endothelium.


Assuntos
Córnea/citologia , Paquimetria Corneana/métodos , Topografia da Córnea/métodos , Densitometria/métodos , Microscopia/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Estudos Transversais , Feminino , Voluntários Saudáveis , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Acuidade Visual , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa