1.
J Am Coll Cardiol ; 23(7): 1666-70, 1994 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-8195529

RESUMO

OBJECTIVES: This study intended to evaluate application of transcatheter occlusion of the patent ductus arteriosus in children < 10 kg body weight. BACKGROUND: Transcatheter occlusion of the patent ductus arteriosus in the child weighing > 10 kg has been proved safe and effective. METHODS: We reviewed 74 consecutive patients weighing < 10 kg (median 8.1 kg, range 3.98 to 10) and aged 4 to 30 months (median 13 months) who underwent patent ductus arteriosus occlusion between June 1986 and November 1992. A modification of the delivery system to facilitate application in small children is described. RESULTS: A 12-mm device was implanted in 50 patients and a 17-mm device in 24. Three device embolizations occurred early in the experience, and one required removal because of hemolysis associated with a moderate residual shunt. One 17-mm device was removed at catheterization because of acute compromise to left pulmonary artery flow after implantation. Prevalence of residual shunting was 33% at 6 months, 20% at 12 to 18 months and 17% at 2-year follow-up and was not related to device, age, weight or size of the patent ductus. Altered flow to the left pulmonary artery was noted in seven patients (9.9%), with more significant compromise associated with the 17-mm device. CONCLUSIONS: Transcatheter patent ductus arteriosus occlusion is feasible in the small child < 10 kg, particularly with the use of a modified delivery system. However, implantation of a 17-mm device in this patient population may impair flow to the left lung and should be reserved for the symptomatic child.


Assuntos
Cateterismo Cardíaco/métodos , Permeabilidade do Canal Arterial/terapia , Pré-Escolar , Permeabilidade do Canal Arterial/fisiopatologia , Feminino , Seguimentos , Humanos , Lactente , Masculino , Artéria Pulmonar/fisiopatologia
2.
J Am Coll Cardiol ; 30(4): 1061-6, 1997 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-9316540

RESUMO

OBJECTIVES: We sought to compare anterograde and retrograde balloon dilation of severe aortic valve stenosis in neonates. BACKGROUND: There is a high incidence of iliofemoral artery complications after retrograde balloon dilation of the aortic valve in the neonate. Therefore, a nonarterial technique of catheter access to the aortic valve would be worth exploring. METHODS: Group 1 included 11 consecutive patients (median age 6 days, range 1 to 42; median weight 3.5 kg, range 2.16 to 4.25) undergoing attempted anterograde dilation through a femoral venous approach. Group 2 included 15 patients (median age 3 days, range 1 to 35; median weight 3.4 kg, range 2.5 to 4.4 kg) who underwent attempted retrograde dilation, including 2 in whom attempted anterograde approach had failed. RESULTS: The valve was successfully crossed in 9 of 11 anterograde and 13 of 15 retrograde dilations. In both groups, the peak gradient across the valve decreased significantly (both p = 0.001). On echocardiography, the jet width of the aortic incompetence/ annulus diameter ratio was 0.16 +/- 0.08 (mean +/- SD) after anterograde and 0.51 +/- 0.24 after retrograde dilation (p = 0.03), possibly because of unrecognized valve leaflet perforation. Two patients in group 1 developed persistent, mild mitral insufficiency. Femoral artery thrombosis developed in one patient after anterograde dilation and in eight after retrograde dilation (p = 0.03). CONCLUSIONS: This series demonstrates that an anterograde approach for balloon angioplasty of severe neonatal aortic valve stenosis is feasible, achieves good hemodynamic relief and lessens morbidity compared with retrograde arterial techniques.


Assuntos
Estenose da Valva Aórtica/terapia , Cateterismo/métodos , Fatores Etários , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/fisiopatologia , Cateterismo/efeitos adversos , Cateterismo/instrumentação , Ecocardiografia Doppler , Feminino , Artéria Femoral/lesões , Hemodinâmica , Humanos , Artéria Ilíaca/lesões , Lactente , Recém-Nascido , Masculino , Índice de Gravidade de Doença
3.
J Am Coll Cardiol ; 30(3): 811-6, 1997 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-9283545

RESUMO

OBJECTIVES: This study was undertaken to investigate the long-term outcome of balloon angioplasty for recurrent coarctation of the aorta in a large series of patients. BACKGROUND: Balloon angioplasty has become the standard treatment for residual or recurrent aortic coarctation. Despite the widespread use of this treatment modality, there are few data outlining the long-term outcome of a large patient cohort. METHODS: Clinical, echocardiographic, hemodynamic and angiographic data on 90 consecutive patients who underwent balloon angioplasty between January 1984 and January 1996 were reviewed. RESULTS: Mean systolic pressure gradients were reduced from 31 +/- 21 to 8 +/- 9 mm Hg after dilation (p = 0.0001). The mean diameter of the stenotic site, measured in the frontal and lateral views, increased by 38% and 35%, respectively (p = 0.001). Neurologic events occurred in two patients, with one death. An aortic tear occurred in one patient, requiring surgical intervention. Optimal results were defined as a postprocedure gradient < 20 mm Hg and were obtained acutely in 88% of patients. At long-term follow-up (12 years), 53 (72%) of 74 patients with an early optimal result remained free from reintervention. Transverse arch hypoplasia, defined as an arch dimension < 2 SD below the mean for age, was the primary predictor of the need for reintervention. CONCLUSIONS: Although the majority of patients undergoing percutaneous balloon angioplasty for recoarctation of the aorta will achieve long-term benefit, the need for further surgical intervention in those with transverse arch hypoplasia remains high.


Assuntos
Angioplastia com Balão , Coartação Aórtica/terapia , Adolescente , Adulto , Angioplastia com Balão/efeitos adversos , Angioplastia com Balão/métodos , Aorta/fisiologia , Coartação Aórtica/fisiopatologia , Coartação Aórtica/cirurgia , Pressão Sanguínea , Criança , Pré-Escolar , Intervalo Livre de Doença , Feminino , Seguimentos , Humanos , Lactente , Masculino , Recidiva , Resultado do Tratamento
4.
J Am Coll Cardiol ; 35(4): 988-96, 2000 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-10732899

RESUMO

OBJECTIVES: We sought to investigate the clinical impact of balloon angioplasty for native coarctation of the aorta (CoA) and determine predictors of outcome. BACKGROUND: Balloon dilation of native CoA remains controversial and more information on its long-term impact is required. METHODS: Hemodynamic, angiographic and follow-up data on 69 children who underwent balloon angioplasty of native CoA between 1988 and 1996 were reviewed. Stretch, recoil and gain of CoA circumference and area were calculated and related to outcomes. RESULTS: Initial systolic gradients (mean +/- SD, 31+/-12 mm Hg) fell by -74+/-27% (p < 0.001), with an increase in mean CoA diameters of 128+/-128% in the left anterior oblique and 124+/-87% in the lateral views (p < 0.001). Two deaths occurred, one at the time of the procedure and one 23 months later, both as a result of an associated cardiomyopathy. Seven patients had residual gradients of >20 mm Hg. One patient developed an aneurysm, stable in follow-up, and four patients had mild dilation at the site of the angioplasty. Freedom from reintervention was 90% at one year and 87% at five years with follow-up ranging to 8.5 years. Factors significantly associated with decreased time to reintervention included: a higher gradient before dilation, a smaller percentage change in gradient after dilation, a small transverse arch and a greater stretch and gain, but not recoil. CONCLUSION: Balloon dilation is a safe and efficient treatment of native CoA in children. Greater stretch and gain are factors significantly associated with reintervention, possibly related to altered elastic properties and vessel scarring.


Assuntos
Angioplastia com Balão , Coartação Aórtica/terapia , Aortografia , Hemodinâmica/fisiologia , Coartação Aórtica/fisiopatologia , Criança , Pré-Escolar , Feminino , Seguimentos , Humanos , Masculino , Retratamento , Sístole/fisiologia , Resultado do Tratamento , Resistência Vascular/fisiologia
5.
J Am Coll Cardiol ; 27(2): 473-8, 1996 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-8557923

RESUMO

OBJECTIVES: This study sought to evaluate ventricular and valvular morphologic changes, hemodynamic consequences and clinical outcomes of pulmonary balloon valvotomy performed in the neonatal period. BACKGROUND: Previous studies support percutaneous balloon valvotomy as the management option of choice for infants and children with valvular pulmonary stenosis. Less information is available to define the impact of valvotomy on the clinical course when performed in the neonatal period. METHODS: Patient records, catheterization data, cineangiograms and selected echocardiograms (initial and most recent studies) of 37 consecutive neonates undergoing attempted balloon dilation were reviewed. RESULTS: Dilation was accomplished in 35 (94%) of 37 attempts. Immediately after dilation, the transvalvular peak to peak systolic gradient decreased from 60 +/- 22 mm Hg (mean +/- SD, range 20 to 100) to 11 +/- 10 mm Hg (range 0 to 45) (p < 0.0001), and the right ventricular/aortic systolic pressure ratio decreased from 1.25 +/- 0.43 (range 0.5 to 2.6) to 0.66 +/- 0.22 (range 0.2 to 1) (p < 0.0001). Oxygen saturation measured by percutaneous oximetry increased from 80 +/- 7% to 92 +/- 4% (p < 0.0001). Three patients died (8%), and two required repeat balloon dilation. At the follow-up visit (median 31 months, range 6 months to 8 years), the estimated peak instantaneous Doppler gradient was 15 +/- 9 mm Hg (range 6 to 36). Thickening of valve leaflets, initially present in 93% of patients, was found in only 4%, and leaflet mobility improved in all. Hypoplasia of the right ventricle, initially present in 31%, was found in only 4% at the latest evaluation. Pulmonary annulus diameter Z score increased from -3 +/- 1.0 to 0 +/- 0.1 (p < 0.0001). Freedom from reintervention was 90%, 84% and 84% at 1, 2 and 8 years, respectively. CONCLUSIONS: These data support the application of balloon valvotomy as the initial intervention in the treatment algorithm for neonates with critical pulmonary valve stenosis. Medium-term follow-up observations demonstrate sustained hemodynamic relief and support maturation of the right ventricle and pulmonary valve annulus, with the expectation of a good long-term outcome.


Assuntos
Cateterismo , Estenose da Valva Pulmonar/terapia , Algoritmos , Cateterismo/efeitos adversos , Cateterismo/estatística & dados numéricos , Feminino , Seguimentos , Hemodinâmica/fisiologia , Humanos , Recém-Nascido , Masculino , Valva Pulmonar/patologia , Estenose da Valva Pulmonar/epidemiologia , Estenose da Valva Pulmonar/fisiopatologia , Fatores de Tempo , Resultado do Tratamento , Função Ventricular Direita/fisiologia
6.
J Am Coll Cardiol ; 32(5): 1433-40, 1998 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-9809959

RESUMO

OBJECTIVES: The aim of this study was to determine the relative risks of pediatric diagnostic, interventional and electrophysiologic catheterizations. BACKGROUND: The role of the pediatric catheterization laboratory has evolved in the last decade as a therapeutic modality, although remaining an important tool for anatomic and hemodynamic diagnosis. METHODS: A study of 4,952 consecutive pediatric catheterization procedures was undertaken. RESULTS: Patient ages ranged from 1 day to 20 years (median 2.9 years). One or more complications occurred in 436 studies (8.8%) and were classified as major in 102 and minor in 458, with vascular complications (n=189; 3.8% of procedures) the most common adverse event. Arrhythmic complications (n=24) were the most common major complication. Death occurred in seven cases (0.14%) as a direct complication of the procedure and was more common in infants (n=5). Independent risk factors for complications included a young patient age and undergoing an interventional procedure. CONCLUSIONS: Complications continue to be associated with pediatric cardiac catheterization. Efforts should be directed to improving equipment for flexibility and size, and finding alternative methods for vascular access. Patient age and interventional studies are risk factors for morbidity and mortality.


Assuntos
Cateterismo Cardíaco/efeitos adversos , Pediatria/métodos , Adolescente , Adulto , Arritmias Cardíacas/etiologia , Cateterismo Cardíaco/mortalidade , Estudos de Casos e Controles , Causas de Morte , Criança , Pré-Escolar , Feminino , Seguimentos , Traumatismos Cardíacos/etiologia , Hemorragia/etiologia , Humanos , Lactente , Recém-Nascido , Masculino , Estudos Prospectivos , Fatores de Risco , Taxa de Sobrevida , Trombose/etiologia
7.
Am J Cardiol ; 77(10): 889-92, 1996 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-8623750

RESUMO

The clinical impact of transcatheter closure of the isolated secundum atrial septal defect was reviewed. Closure by echocardiographic evaluation was 23 +/- 14% at 6 months, 49 +/- 16% at 2 years, and 64 +/- 16% at 4 years, and right ventricular end-diastolic dimensions in patients without residual shunts did not differ significantly from those with residual shunts.


Assuntos
Cateterismo Cardíaco , Comunicação Interatrial/terapia , Próteses e Implantes , Adolescente , Cateterismo Cardíaco/instrumentação , Criança , Pré-Escolar , Ecocardiografia Transesofagiana , Comunicação Interatrial/diagnóstico por imagem , Comunicação Interatrial/fisiopatologia , Hemodinâmica , Humanos , Estudos Retrospectivos , Análise de Sobrevida , Resultado do Tratamento
8.
Am J Cardiol ; 71(13): 1198-203, 1993 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-8480646

RESUMO

Recently, a case of right isomerism with totally anomalous pulmonary venous connection (TAPVC) to the innominate vein through a vertical vein that ascended in the mediastinum posterior to the left-sided main bronchus was encountered. This retrobronchial vertical vein that has not been described previously in patients with TAPVC to the innominate vein prompted the performance of a retrospective analysis of 44 cases with TAPVC to the innominate vein in which angiography had been performed. The 44 cases consisted of 36 patients with situs solitus, 7 with right isomerism, and 1 with left isomerism. The spatial relation of the vertical vein to the adjacent pulmonary artery and main bronchus could be defined in 41 cases. The vertical vein was retrobronchial in 4 of 5 cases with right isomerism in which the location of the vertical vein could be defined with certainty. No case with situs solitus or left isomerism was associated with a retrobronchial vertical vein. In all 4 patients with a retrobronchial vertical vein, angiographic evidence of obstruction of pulmonary venous drainage was present, and was due to an extrinsic bronchial compression in 2 and to an intrinsic narrowing of the vertical vein in 2.


Assuntos
Anormalidades Múltiplas/diagnóstico por imagem , Veias Braquiocefálicas/anormalidades , Cardiopatias Congênitas/diagnóstico por imagem , Veias Pulmonares/anormalidades , Adolescente , Veias Braquiocefálicas/diagnóstico por imagem , Criança , Pré-Escolar , Feminino , Humanos , Lactente , Recém-Nascido , Masculino , Veias Pulmonares/diagnóstico por imagem , Radiografia , Estudos Retrospectivos
9.
Am J Cardiol ; 87(1): 76-81, 2001 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-11137838

RESUMO

A randomized trial of arterial duct occlusion with a double umbrella (DU) or wire coil (WC) was undertaken for patients <18 years of age, weighing >10 kg with isolated ducts < or = 3 mm in diameter. Baseline, procedural, and outcome characteristics were compared in an intention-to-treat analysis according to randomization group. From 40 consecutively screened patients, 2 were not enrolled due to a ductal diameter of >3 mm on initial aortography, 38 patients were randomized to either the DU (n = 20) or WC (n = 18) groups. The groups did not differ significantly with respect to age, weight, gender, duct size, type, or branch pulmonary artery diameters. Crossover occurred only in the DU group, where 4 patients (20%) had a ductal diameter of < or = 1 mm and could not be entered for umbrella placement. All remaining DU group patients had ductal diameters of > or = 1.3 mm (p <0.0001). There were no embolizations or secondary implants in the DU group, but in the WC group there was 1 early and 1 late embolization, with 6 patients (33%) with > or = 2 coils. Mean times for the procedure (DU 68+/-19 minutes; WC 65+/-27 minutes; p = 0.70) and fluoroscopy (DU 14+/-4 minutes; WC 11+/-6 minutes; p = 0.22) did not differ significantly. Angiographic duct closure was documented in 4 of 13 patients (31%) of the DU group and 4 of 18 patients (22%) of the WC group (p = 0.69). Combined with an echocardiogram, closure in 11 of 17 patients with DU (65%) and 13 of 18 patients with WC (72%) (p = 0.64) was documented before hospital discharge. One WC group patient received thrombolytic therapy for a femoral artery thrombus. Follow-up at a median of 6.5 months (range 3.2 to 37) showed closure by Doppler echocardiography in 15 of 19 patients with DU (79%) versus 14 of 18 patients with WC (78%) (p = 1.0). Thus, with a tendency toward similar procedural characteristics and outcomes, the higher cost of the DU system compared with coil implants favors the use of coils for closure of the small arterial duct.


Assuntos
Cateterismo Cardíaco/instrumentação , Cateterismo Cardíaco/métodos , Permeabilidade do Canal Arterial/terapia , Próteses e Implantes , Análise de Variância , Cateterismo Cardíaco/efeitos adversos , Pré-Escolar , Constrição Patológica/etiologia , Angiografia Coronária , Permeabilidade do Canal Arterial/diagnóstico por imagem , Ecocardiografia Doppler , Falha de Equipamento , Humanos , Lactente , Próteses e Implantes/efeitos adversos , Artéria Pulmonar/patologia , Método Simples-Cego , Estatísticas não Paramétricas , Resultado do Tratamento
10.
J Thorac Cardiovasc Surg ; 118(5): 886-93, 1999 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-10534694

RESUMO

OBJECTIVE: Extracardiac conduits between the right ventricle and pulmonary arteries commit patients to multiple reoperations. We reviewed our experience with stent implantation in obstructed conduits. METHODS: Between 1990 and 1997, stents were implanted across 43 conduits. The median age at procedure was 6 years (0.5-17 years), and the median interval between conduit insertion and stent implantation was 2.4 years (0.3-14 years). RESULTS: Mean systolic right ventricular pressures and gradients, respectively, decreased from 71 +/- 18 mm Hg and 48 +/- 19 mm Hg before to 48 +/- 15 mm Hg and 19 +/- 13 mm Hg after stent placement. Mean percentage of predicted valve area for body surface area increased from 26% +/- 12% to 48% +/- 17% after stent placement. Fifteen patients underwent a second transcatheter intervention (dilation or additional stent), and 2 patients, a third, allowing further postponement of surgery in 8 patients. One sudden death occurred 2.8 years after stent placement. Surgical conduit replacement has occurred in 20 patients. Body growth was maintained during follow-up. Freedom from surgical reintervention was 86% at 1 year, 72% at 2 years, and 47% at 4 years. Higher right ventricular pressure and gradient before and after stent placement and lower percentage of predicted valve area for body surface area after stent placement were associated with shorter palliation. CONCLUSION: Endovascular stent placement across obstructed conduits is a safe and effective palliation that allows for normal body growth.


Assuntos
Stents , Obstrução do Fluxo Ventricular Externo/terapia , Cateterismo Cardíaco , Criança , Feminino , Seguimentos , Cardiopatias Congênitas/cirurgia , Humanos , Masculino , Cuidados Paliativos/métodos , Complicações Pós-Operatórias/cirurgia , Complicações Pós-Operatórias/terapia , Implantação de Prótese , Fatores de Tempo , Obstrução do Fluxo Ventricular Externo/etiologia , Obstrução do Fluxo Ventricular Externo/cirurgia
11.
J Thorac Cardiovasc Surg ; 110(5): 1513-9; discussion 1519-20, 1995 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-7475204

RESUMO

The use of endovascular devices as an adjunct to repair of congenital heart anomalies represents a novel but unproven therapeutic approach. Intraoperative implantation of pulmonary arterial stents (5 to 15 mm diameter) was done in 11 patients with pulmonary atresia with ventricular septal defect (n = 4), classic tetralogy of Fallot (n = 2), truncus arteriosus (n = 1), hypoplastic left heart syndrome (stage II [n = 1] and stage III [n = 1] Norwood procedure), and miscellaneous pulmonary arterial stenoses (n = 3), as well as in patients with congenital (n = 1) and postoperative (n = 3) pulmonary venous obstruction and in 1 patient with combined pulmonary arterial and venous obstruction. The stents were effective at achieving immediate patency in all patients. There were two early deaths, one related to acute thrombosis of a small-diameter left pulmonary artery stent. Reintervention because of stent-related pulmonary arterial stenosis was frequently necessary. In five of seven patients who survived more than 1 month after implantation of stent size 8 mm or smaller severe stent-related pulmonary arterial obstruction developed. In four of the five patients with pulmonary vein stent implantation intractable obstruction developed, resulting in death in all three patients who had bilateral pulmonary vein stent implantation. Intraoperative occlusion of apical muscular ventricular septal defect with use of a clamshell device inserted from the right atrial approach was accomplished in four patients. One patient who underwent associated aortic arch reconstruction died as a result of left ventricular hypoplasia. The results in the remaining three patients were favorable on the basis of absence of significant late residual intraventricular shunting, left ventricular dysfunction, or arrhythmia. We conclude that recurrent intraluminal obstruction as a result of neointimal hyperplasia appears to be an eventual certainty in currently designed small-diameter endovascular stents. For this reason, we would recommend standard surgical techniques for repair of obstructive lesions of the pulmonary arterial confluence to maximize growth potential. Device occlusion of muscular ventricular septal defects is feasible but probably only indicated for complex cases of ventricular septal deficiency that otherwise necessitate a left ventriculotomy.


Assuntos
Cardiopatias Congênitas/cirurgia , Artéria Pulmonar/cirurgia , Stents , Adolescente , Criança , Pré-Escolar , Seguimentos , Cardiopatias Congênitas/mortalidade , Comunicação Interventricular/complicações , Humanos , Síndrome do Coração Esquerdo Hipoplásico/cirurgia , Lactente , Recém-Nascido , Complicações Pós-Operatórias , Atresia Pulmonar/cirurgia , Estenose da Valva Pulmonar/cirurgia , Veias Pulmonares/cirurgia , Tetralogia de Fallot/cirurgia , Persistência do Tronco Arterial/cirurgia
12.
Ann Thorac Surg ; 66(2): 664-7, 1998 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-9725449

RESUMO

This article reviews the indications for the bidirectional cavopulmonary connection and demonstrates its efficacy in reducing mortality for the Fontan procedure. The indications for adding an additional source of pulmonary blood flow to the bidirectional cavopulmonary connection are discussed, but this issue remains controversial. Also unclear is whether the bidirectional cavopulmonary connection promotes symmetric growth of the pulmonary arteries, or whether growth of the left pulmonary artery is disadvantaged. Finally, systemic venous collateralization is a well-recognized sequel after cavopulmonary connection. The clinical implications of this collateralization are reviewed.


Assuntos
Anastomose Cirúrgica/métodos , Artéria Pulmonar/cirurgia , Veia Cava Superior/cirurgia , Pré-Escolar , Técnica de Fontan/mortalidade , Cardiopatias Congênitas/cirurgia , Humanos
13.
Ann Thorac Surg ; 72(2): 416-23, 2001 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-11515876

RESUMO

BACKGROUND: The surgical management of muscular ventricular septal defects (mVSD) in the small infant is a challenge particularly when multiple and associated with complex cardiac lesions. Devices for percutaneous implantation have the advantage of ease of placement and for the double umbrella designs a wide area of coverage. We reviewed our experience and clinical outcomes of intraoperative mVSD device closure for such defects in small infants. METHODS: Since October 1989, intraoperative VSD device closure was a component of the surgical strategy in 14 consecutive patient implants (median age, 5.5 months; range, 3 to 11 kg), whose defects were thought difficult to approach using conventional techniques. Nine patients had associated complex cardiac lesions, 10 multiple mVSDs, and 4 patients had a previous pulmonary artery banding. RESULTS: There were 2 early deaths, 1 in a severely ill child who preoperatively had pulmonary hypertension and left ventricular failure and another in a patient with a hypoplastic left heart. Mean pulmonary to systemic flow ratio before device insertion was 3.5:1. Complete closure was achieved in 5 patients and clinically insignificant residual shunts persisted in 7. In 2 infants with significant residual lesions concomitant pulmonary artery banding was required. Postoperative mean pulmonary to systemic flow ratio was 1.7:1. In follow-up of the 12 surviving infants (mean, 41 months), 8 had complete closure and 3 persistent residual shunts. One patient with no residual shunting required heart transplantation for progressive ventricular failure 9 years after operation. All devices were well positioned on postoperative echocardiograms. There was 1 late death due to aspiration in a patient with a tiny residual shunt. CONCLUSIONS: Infants requiring operative intervention with mVSDs are difficult to manage and have an increased mortality and morbidity. Intraoperative VSD device placement for closure of mVSDs is feasible, can avoid ventriculotomy, division of intracardiac muscle bands, and is ideally suited for the neonate or infant.


Assuntos
Cardiopatias Congênitas/cirurgia , Comunicação Interventricular/cirurgia , Complicações Pós-Operatórias/diagnóstico por imagem , Implantação de Prótese , Ecocardiografia , Ecocardiografia Transesofagiana , Feminino , Seguimentos , Cardiopatias Congênitas/diagnóstico por imagem , Cardiopatias Congênitas/mortalidade , Comunicação Interventricular/diagnóstico por imagem , Comunicação Interventricular/mortalidade , Humanos , Lactente , Recém-Nascido , Masculino , Complicações Pós-Operatórias/mortalidade , Reoperação , Taxa de Sobrevida
14.
Ann Thorac Surg ; 71(5): 1541-6, 2001 May.
Artigo em Inglês | MEDLINE | ID: mdl-11383797

RESUMO

BACKGROUND: Outcomes of the Fontan operation in children initially palliated with the modified Norwood procedure are incompletely defined. METHODS: From August 1993 to January 2000, 45 patients (mean age 2.6 +/- 1.1 years, weight 12.7 +/- 2.8 kg) who were palliated with staged Norwood procedures (hypoplastic left heart syndrome, n = 32; nonhypoplastic left heart syndrome, n = 13) underwent a modified Fontan operation. Preoperative features included moderate/severe atrioventricular valve regurgitation (n = 5, 11%), reduced ventricular function on echocardiography in 11 patients, McGoon index 1.56 +/- 0.38, and pulmonary artery distortion in 18 patients (40%). RESULTS: A lateral tunnel (n = 16) or an extracardiac conduit (n = 29) connection with fenestration in 38 patients (84%) was used. Concomitant procedures included pulmonary artery reconstruction (n = 24, 53%), atrioventricular valve repair (n = 4, 9%) or replacement (n = 1). Before Fontan, 12 patients (27%) had an intervention to address neoaortic obstruction, and 7 patients required balloon dilation/stenting of the left (n = 5) or right pulmonary artery (n = 5). Intraoperatively, left (n = 5) or right pulmonary artery (n = 1) stenting was performed in 5 patients (11%). On follow-up, 8 patients required additional interventional procedures to address left pulmonary artery narrowing (n = 5), or venous (n = 5) or arteriopulmonary collaterals (n = 1). Perioperative mortality was 4.4% (n = 2). There were 2 late deaths at a mean follow-up of 39 +/- 20 months. CONCLUSIONS: In relatively high-risk patients, midterm results of the Fontan operation for children initially palliated with the Norwood procedure were good. Combined interventional-surgical treatment algorithms can lead to improved outcomes.


Assuntos
Técnica de Fontan , Derivação Cardíaca Direita/métodos , Cardiopatias Congênitas/cirurgia , Síndrome do Coração Esquerdo Hipoplásico/cirurgia , Criança , Pré-Escolar , Feminino , Seguimentos , Cardiopatias Congênitas/mortalidade , Hemodinâmica/fisiologia , Mortalidade Hospitalar , Humanos , Síndrome do Coração Esquerdo Hipoplásico/mortalidade , Lactente , Masculino , Cuidados Paliativos , Complicações Pós-Operatórias/mortalidade , Complicações Pós-Operatórias/cirurgia , Reoperação , Taxa de Sobrevida
15.
Heart ; 79(5): 509-12, 1998 May.
Artigo em Inglês | MEDLINE | ID: mdl-9659202

RESUMO

Persistent left superior vena cava (SVC) is a not uncommon finding in patients with congenital heart disease. This anatomical variant must be recognised before doing a Glenn anastomosis, bidirectional cavopulmonary connection or a Fontan-type procedure. Following these procedures, reopening of a left SVC leading to clinical cyanosis can occur. Five cases are described in whom persisting left SVCs were excluded before performing a bidirectional cavopulmonary connection or Fontan procedure but (re-)opened after surgery, leading to cyanosis either by reducing effective pulmonary blood flow (bidirectional cavopulmonary connection) or by an obligatory right to left shunt (Fontan). These observations suggest that, embryologically, the lumen of the left SVC obliterates rather than disappears. Balloon occlusion angiography of the innominate vein before cavopulmonary connections or Fontan procedures might improve detection of these collateral vessels.


Assuntos
Circulação Colateral , Derivação Cardíaca Direita , Complicações Pós-Operatórias/diagnóstico , Veia Cava Superior/anormalidades , Pré-Escolar , Cianose/diagnóstico por imagem , Cianose/etiologia , Técnica de Fontan , Humanos , Complicações Pós-Operatórias/cirurgia , Radiografia , Veia Cava Superior/diagnóstico por imagem
16.
Can J Cardiol ; 19(13): 1493-7, 2003 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-14760439

RESUMO

OBJECTIVES: To assess the efficacy and safety of transcatheter reocclusion of persistent leaks following previously attempted transcatheter occlusion of persistent arterial duct. DESIGN: Retrospective study. SETTING: Tertiary pediatric cardiology centre. PATIENTS: From February 1987 through October 1996, trans-catheter occlusion of a residual ductal shunt was attempted in 42 consecutive patients at a median age of 5.0 years (range 1.6 years to 16.2 years). INTERVENTIONS: Fourty patients had successful placement of a double umbrella occluder (n=27) or coils (n=13) across residual shunts. Complications included device embolization in two patients and hemolysis in one patient. OUTCOME MEASURES AND RESULTS: Mean z-score for left ventricular end-diastolic dimension (LVEDD) at initial echocardiography was +2.55 +/- 1.89 (P<0.0001 versus normal); z-score for left pulmonary artery (LPA) diameter was +2.00 +/- 1.52 (P<0.0001). Mean LPA to right pulmonary artery (RPA) diameter ratio was 1.05 +/- 0.18. At follow-up echocardiogram, a median of two years (range six months to 7.7 years) after the second procedure, a shunt was persistent in 3% of the patients. Mean LVEDD and LPA diameter z-value, and mean LPA to RPA diameter had dropped significantly to +0.42 +/- 1.31, +0.07 +/- 1.15 and 0.86 +/- 0.14 (P<0.001), respectively. LPA flow acceleration was present in 25% of patients. Three of nine patients, in whom lung perfusion scan was performed, had left lung perfusion below 40%. Small weight and age at catheterization were significant risk factors for LPA flow disturbance. CONCLUSIONS: Repeat transcatheter occlusion is safe and successful in eliminating residual shunt across the arterial duct. Attention should, however, be addressed to the potential for LPA stenosis and growth, and flow should be regularly assessed.


Assuntos
Cateterismo , Permeabilidade do Canal Arterial/terapia , Embolização Terapêutica , Adolescente , Velocidade do Fluxo Sanguíneo , Cateterismo/efeitos adversos , Criança , Pré-Escolar , Permeabilidade do Canal Arterial/diagnóstico por imagem , Permeabilidade do Canal Arterial/fisiopatologia , Ecocardiografia , Feminino , Humanos , Lactente , Masculino , Artéria Pulmonar/diagnóstico por imagem , Retratamento , Estudos Retrospectivos
17.
Pediatr Clin North Am ; 46(2): 441-64, 1999 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-10218085

RESUMO

Over the past decade, transcatheter interventions have become increasingly important in the treatment of patients with congenital heart lesions. These procedures may be broadly grouped as dilations (e.g., septostomy, valvuloplasty, angioplasty, and endovascular stenting) or as closures (e.g., vascular embolization and device closure of defects). Balloon valvuloplasty has become the treatment of choice for patients in all age groups with simple valvar pulmonic stenosis and, although not curative, seems at least comparable to surgery for congenital aortic stenosis in newborns to young adults. Balloon angioplasty is successfully applied to a wide range of aortic, pulmonary artery, and venous stenoses. Stents are useful in dilating lesions of which the intrinsic elasticity results in vessel recoil after balloon dilation alone. Catheter-delivered coils are used to embolize a wide range of arterial, venous, and prosthetic vascular connections. Although some devices remain investigational, they have been successfully used for closure of many arterial ducts and atrial and ventricular septal defects. In the therapy for patients with complex CHD, best results may be achieved by combining cardiac surgery with interventional catheterization. The cooperation among interventional cardiologists and cardiac surgeons was highlighted in a report of an algorithm to manage patients with tetralogy of Fallot or pulmonary atresia with diminutive pulmonary arteries, involving balloon dilation, coil embolization of collaterals, and intraoperative stent placement. In this setting, well-planned catheterization procedures have an important role in reducing the overall number of procedures that patients may require over a lifetime, with improved outcomes.


Assuntos
Cateterismo Cardíaco/métodos , Cateterismo/métodos , Cardiopatias/diagnóstico , Cardiopatias/terapia , Radiografia Intervencionista/métodos , Adolescente , Adulto , Algoritmos , Procedimentos Cirúrgicos Cardíacos , Criança , Pré-Escolar , Terapia Combinada , Humanos , Lactente , Recém-Nascido , Pediatria , Stents , Resultado do Tratamento