Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 68
Filtrar
1.
J Infect Dis ; 229(4): 1229-1238, 2024 Apr 12.
Artigo em Inglês | MEDLINE | ID: mdl-37788578

RESUMO

Positron emission tomography-computed tomography (PET-CT) has the potential to revolutionize research in infectious diseases, as it has done with cancer. There is growing interest in it as a biomarker in the setting of early-phase tuberculosis clinical trials, particularly given the limitations of current biomarkers as adequate predictors of sterilizing cure for tuberculosis. PET-CT is a real-time tool that provides a 3-dimensional view of the spatial distribution of tuberculosis within the lung parenchyma and the nature of lesions with uptake (ie, whether nodular, consolidative, or cavitary). Its ability to provide functional data on changes in metabolism, drug penetration, and immune control of tuberculous lesions has the potential to facilitate drug development and regimen selection for advancement to phase 3 trials in tuberculosis. In this narrative review, we discuss the role that PET-CT may have in evaluating responses to drug therapy in active tuberculosis treatment and the challenges in taking PET-CT forward as predictive biomarker of relapse-free cure in the setting of phase 2 clinical trials.


Assuntos
Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Tuberculose , Humanos , Tuberculose/diagnóstico por imagem , Tuberculose/tratamento farmacológico , Tuberculose/metabolismo , Pulmão/patologia , Recidiva , Biomarcadores , Fluordesoxiglucose F18/uso terapêutico , Tomografia por Emissão de Pósitrons , Ensaios Clínicos Fase II como Assunto
2.
Emerg Radiol ; 31(1): 73-82, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38224366

RESUMO

PURPOSE: Acute chest syndrome (ACS) is secondary to occlusion of the pulmonary vasculature and a potentially life-threatening complication of sickle cell disease (SCD). Dual-energy CT (DECT) iodine perfusion map reconstructions can provide a method to visualize and quantify the extent of pulmonary microthrombi. METHODS: A total of 102 patients with sickle cell disease who underwent DECT CTPA with perfusion were retrospectively identified. The presence or absence of airspace opacities, segmental perfusion defects, and acute or chronic pulmonary emboli was noted. The number of segmental perfusion defects between patients with and without acute chest syndrome was compared. Sub-analyses were performed to investigate robustness. RESULTS: Of the 102 patients, 68 were clinically determined to not have ACS and 34 were determined to have ACS by clinical criteria. Of the patients with ACS, 82.4% were found to have perfusion defects with a median of 2 perfusion defects per patient. The presence of any or new perfusion defects was significantly associated with the diagnosis of ACS (P = 0.005 and < 0.001, respectively). Excluding patients with pulmonary embolism, 79% of patients with ACS had old or new perfusion defects, and the specificity for new perfusion defects was 87%, higher than consolidation/ground glass opacities (80%). CONCLUSION: DECT iodine map has the capability to depict microthrombi as perfusion defects. The presence of segmental perfusion defects on dual-energy CT maps was found to be associated with ACS with potential for improved specificity and reclassification.


Assuntos
Síndrome Torácica Aguda , Anemia Falciforme , Iodo , Embolia Pulmonar , Humanos , Síndrome Torácica Aguda/diagnóstico por imagem , Estudos Retrospectivos , Angiografia/métodos , Reprodutibilidade dos Testes , Tomografia Computadorizada por Raios X/métodos , Pulmão , Embolia Pulmonar/diagnóstico por imagem , Anemia Falciforme/complicações , Anemia Falciforme/diagnóstico por imagem , Perfusão
3.
Pol J Radiol ; 89: e63-e69, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38371894

RESUMO

Purpose: Computed tomography (CT) pulmonary angiography is considered the gold standard for pulmonary embolism (PE) diagnosis, relying on the discrimination between contrast and embolus. Photon-counting detector CT (PCD-CT) generates monoenergetic reconstructions through energy-resolved detection. Virtual monoenergetic images (VMI) at low keV can be used to improve pulmonary artery opacification. While studies have assessed VMI for PE diagnosis on dual-energy CT (DECT), there is a lack of literature on optimal settings for PCD-CT-PE reconstructions, warranting further investigation. Material and methods: Twenty-five sequential patients who underwent PCD-CT pulmonary angiography for suspicion of acute PE were retrospectively included in this study. Quantitative metrics including signal-to-noise ratio (SNR) and contrast-to-noise (CNR) ratio were calculated for 4 VMI values (40, 60, 80, and 100 keV). Qualitative measures of diagnostic quality were obtained for proximal to distal pulmonary artery branches by 2 cardiothoracic radiologists using a 5-point modified Likert scale. Results: SNR and CNR were highest for the 40 keV VMI (49.3 ± 22.2 and 48.2 ± 22.1, respectively) and were inversely related to monoenergetic keV. Qualitatively, 40 and 60 keV both exhibited excellent diagnostic quality (mean main pulmonary artery: 5.0 ± 0 and 5.0 ± 0; subsegmental pulmonary arteries 4.9 ± 0.1 and 4.9 ± 0.1, respectively) while distal segments at high (80-100) keVs had worse quality. Conclusions: 40 keV was the best individual VMI for the detection of pulmonary embolism by quantitative metrics. Qualitatively, 40-60 keV reconstructions may be used without a significant decrease in subjective quality. VMIs at higher keV lead to reduced opacification of the distal pulmonary arteries, resulting in decreased image quality.

4.
Radiology ; 307(2): e222030, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-36719292

RESUMO

Background Photon-counting detector (PCD) CT provides comprehensive spectral data with every acquisition, but studies evaluating myocardial extracellular volume (ECV) quantification with use of PCD CT compared with an MRI reference remain lacking. Purpose To compare ECV quantification for myocardial tissue characterization between a first-generation PCD CT system and cardiac MRI. Materials and Methods In this single-center prospective study, adults without contraindication to iodine-based contrast media underwent same-day cardiac PCD CT and MRI with native and postcontrast T1 mapping and late gadolinium enhancement for various clinical indications for cardiac MRI (the reference standard) between July 2021 and January 2022. Global and midventricular ECV were assessed with use of three methods: single-energy PCD CT, dual-energy PCD CT, and MRI T1 mapping. Quantitative comparisons among all techniques were performed. Correlation and reliability between different methods of ECV quantification were assessed with use of the Pearson correlation coefficient (r) and the intraclass correlation coefficient. Results The final sample included 29 study participants (mean age ± SD, 54 years ± 17; 15 men). There was a strong correlation of ECV between dual- and single-energy PCD CT (r = 0.91, P < .001). Radiation dose was 40% lower with dual-energy versus single-energy PCD CT (volume CT dose index, 10.1 mGy vs 16.8 mGy, respectively; P < .001). In comparison with MRI, dual-energy PCD CT showed strong correlation (r = 0.82 and 0.91, both P < .001) and good to excellent reliability (intraclass correlation coefficients, 0.81 and 0.90) for midventricular and global ECV quantification, but it overestimated ECV by approximately 2%. Single-energy PCD CT showed similar relationship with MRI but underestimated ECV by 3%. Conclusion Myocardial tissue characterization with photon-counting detector CT-based quantitative extracellular volume analysis showed a strong correlation to MRI. © RSNA, 2023 Supplemental material is available for this article.


Assuntos
Meios de Contraste , Gadolínio , Masculino , Adulto , Humanos , Estudos Prospectivos , Reprodutibilidade dos Testes , Tomografia Computadorizada por Raios X/métodos , Imageamento por Ressonância Magnética/métodos
5.
Eur Radiol ; 33(4): 2469-2477, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-36462045

RESUMO

OBJECTIVES: To assess the impact of scan modes and reconstruction kernels using a novel dual-source photon-counting detector CT (PCD-CT) on lumen visibility and sharpness of different stent sizes. METHODS: A phantom containing six balloon-expandable stents (2.5 to 9 mm diameter) in silicone tubing was scanned on a PCD-CT with standard (0.6 mm and 0.4 mm thicknesses) and ultra-high-resolution (0.2 mm thickness) modes. With the use of increasing contrast medium concentrations, densities of 0, 200, 400, and 600 HU were achieved. Standard-resolution scans were reconstructed using increasing sharpness kernels, using both polyenergetic quantitative soft tissue "conventional" ((Qr40c(0.6 mm), Qr40c(0.4 mm), Qr72c(0.2 mm)) and vascular (Bv) virtual monoenergetic reconstructions (Bv44m(0.4 mm), Bv60m(0.4 mm)) at 70 keV. In-stent lumen visibility, sharpness (max. ΔHU of the stent measured in profile plots), and in-stent noise (standard deviation of HU) were measured. RESULTS: In-stent lumen visibility was highest for Qr72c(0.2 mm) (86.5 ± 2.8% to 88.3 ± 2.6%) and in Bv60m(0.4 mm) reconstructions (77.3 ± 2.9 to 82.7 ± 2.5%). Lumen visibility was lowest in the smallest stent (2.5 mm) ranging from 54.1% in Qr40c(0.6 mm) to 74.1% in Qr72c(0.2 mm) and highest in the largest stent (9 mm) ranging from 93.8% in Qr40c(0.6 mm) to 99.1% in the Qr72c(0.2 mm) series. Lumen visibility decreased by 2.1% for every 200-HU increase in lumen attenuation. Max. ΔHU between stents and stent lumen was highest in Qr72c(0.2 mm) (ΔHU 892 ± 504 to 1526 ± 517) and Bv60m(0.4 mm) series (ΔHU 480 ± 357 to 1030 ± 344). Improvement of lumen visibility and sharpness in UHR and Bv60m(0.4 mm) series was strongest in smaller stent sizes. CONCLUSION: UHR acquisition mode and sharp reconstruction kernels on a novel PCD-CT system significantly improve in-stent lumen visibility and sharpness-especially for smaller stent sizes. KEY POINTS: • In-stent lumen visibility and sharpness of stents significantly improve using sharp reconstruction kernels (Bv60) and ultra-high-resolution mode in photon-counting detector computed tomography. • The observed improvement of stent-lumen visibility was highest in smaller stent sizes.


Assuntos
Stents , Tomografia Computadorizada por Raios X , Humanos , Angiografia Coronária/métodos , Tomografia Computadorizada por Raios X/métodos , Meios de Contraste , Imagens de Fantasmas
6.
Eur J Nucl Med Mol Imaging ; 48(6): 1842-1853, 2021 06.
Artigo em Inglês | MEDLINE | ID: mdl-33415430

RESUMO

PURPOSE: Standardized uptake value ratio (SUVr) used to quantify amyloid-ß burden from amyloid-PET scans can be biased by variations in the tracer's nonspecific (NS) binding caused by the presence of cerebrovascular disease (CeVD). In this work, we propose a novel amyloid-PET quantification approach that harnesses the intermodal image translation capability of convolutional networks to remove this undesirable source of variability. METHODS: Paired MR and PET images exhibiting very low specific uptake were selected from a Singaporean amyloid-PET study involving 172 participants with different severities of CeVD. Two convolutional neural networks (CNN), ScaleNet and HighRes3DNet, and one conditional generative adversarial network (cGAN) were trained to map structural MR to NS PET images. NS estimates generated for all subjects using the most promising network were then subtracted from SUVr images to determine specific amyloid load only (SAßL). Associations of SAßL with various cognitive and functional test scores were then computed and compared to results using conventional SUVr. RESULTS: Multimodal ScaleNet outperformed other networks in predicting the NS content in cortical gray matter with a mean relative error below 2%. Compared to SUVr, SAßL showed increased association with cognitive and functional test scores by up to 67%. CONCLUSION: Removing the undesirable NS uptake from the amyloid load measurement is possible using deep learning and substantially improves its accuracy. This novel analysis approach opens a new window of opportunity for improved data modeling in Alzheimer's disease and for other neurodegenerative diseases that utilize PET imaging.


Assuntos
Doença de Alzheimer , Aprendizado Profundo , Amiloide/metabolismo , Peptídeos beta-Amiloides , Compostos de Anilina , Encéfalo/metabolismo , Humanos , Tomografia por Emissão de Pósitrons
7.
Mol Pharm ; 18(9): 3616-3622, 2021 09 06.
Artigo em Inglês | MEDLINE | ID: mdl-34328338

RESUMO

Accurate determination of human epidermal growth factor receptor 2 (HER2) expression is essential for HER2-targeted therapy in patients with cancer. HER2 expression in a complex environment, such as in a heterogeneous tumor, makes the precise assessment of the HER2 status difficult using current methods. In this study, we developed a novel 99mTc-labeled anti-HER2 single-domain antibody (99mTc-NM-02) as a molecular imaging tracer for the noninvasive detection of HER2 expression and investigated its safety, radiation dosimetry, biodistribution, and tumor-targeting potential in 10 patients with breast cancer. Our data showed that no drug-related adverse reactions occurred. The tracer mainly accumulated in the kidneys and liver with mild uptake in the spleen, intestines, and thyroid; however, only background tracer levels were observed in other organs where primary tumors and metastases typically occurred. The mean effective dose was 6.56 × 10-3 mSv/MBq, and tracer uptake was visually observed in the primary tumors and metastases. A maximal standard uptake value of 1.5 was determined as a reasonable cutoff for identifying HER2 positivity using SPECT/CT imaging. Our 99mTc-NM-02 tracer is safe for use in breast cancer imaging, with reasonable radiation doses, favorable biodistribution, and imaging characteristics. 99mTc-NM-02 SPECT imaging may be an accurate and noninvasive method to detect the HER2 status in patients with breast cancer.


Assuntos
Neoplasias da Mama/diagnóstico , Compostos Radiofarmacêuticos/administração & dosagem , Receptor ErbB-2/análise , Anticorpos de Domínio Único/administração & dosagem , Adulto , Neoplasias da Mama/patologia , Feminino , Humanos , Pessoa de Meia-Idade , Imagem Molecular/métodos , Compostos Radiofarmacêuticos/farmacocinética , Receptor ErbB-2/antagonistas & inibidores , Receptor ErbB-2/metabolismo , Tomografia Computadorizada com Tomografia Computadorizada de Emissão de Fóton Único/métodos , Tecnécio , Distribuição Tecidual
8.
J Nucl Cardiol ; 24(1): 282-290, 2017 02.
Artigo em Inglês | MEDLINE | ID: mdl-27435278

RESUMO

ABSTACT: OBJECTIVES: Myocardial blood flow (MBF) imaging is used in patients with suspected cardiac sarcoidosis, and also in stress/rest studies. The accuracy of MBF is dependent on imaging parameters such as new reconstruction methodologies. In this work, we aim to assess the impact of a novel PET reconstruction algorithm (Bayesian-penalized likelihood-BPL) on the values determined from the calculation of [13N]-NH3 MBF values. METHODS: Data from 21 patients undergoing rest MBF evaluation [13N]-NH3 as part of sarcoidosis imaging were retrospectively analyzed. Each scan was reconstructed with a range of BPL coefficients (1-500), and standard clinical FBP and OSEM reconstructions. MBF values were calculated via an automated software routine for all datasets. RESULTS: Reconstruction of [13N]-NH3 dynamic data using the BPL, OSEM, or FBP reconstruction showed no quantitative differences for the calculation of territorial or global MBF (P = .97). Image noise was lower using OSEM or BPL reconstructions than FBP and noise from BPL reached levels seen in OSEM images between B = 300 and B = 400. Intrasubject differences between all reconstructions over all patients in respect of all cardiac territories showed a maximum coefficient of variation of 9.74%. CONCLUSION: Quantitation of MBF via kinetic modeling of cardiac rest MBF by [13N]-NH3 is minimally affected by the use of a BPL reconstruction technique, with BPL images presenting with less noise.


Assuntos
Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/fisiopatologia , Circulação Coronária , Interpretação de Imagem Assistida por Computador/métodos , Imagem de Perfusão do Miocárdio/métodos , Radioisótopos de Nitrogênio , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Algoritmos , Teorema de Bayes , Velocidade do Fluxo Sanguíneo , Interpretação Estatística de Dados , Feminino , Humanos , Aumento da Imagem/métodos , Funções Verossimilhança , Masculino , Pessoa de Meia-Idade , Compostos Radiofarmacêuticos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
9.
J Nucl Cardiol ; 21(5): 944-53, 2014 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-25080871

RESUMO

BACKGROUND: The technique of SPECT-RNV (radionuclide ventriculography) offers a greater amount of clinically usable data than its planar counterpart (P-RNV). In transitioning from planar to SPECT-only acquisition methodologies, reprojection of the SPECT data can provide a planar dataset which can be used as an interim technique. The aim of this study was to test if reprojected planar images could be used as a surrogate for true planar images in SPECT-only setting. METHODS: We performed SPECT-RNV and P-RNV on 47 patients on traditional sodium iodide (NaI) cameras, determining left ventricular ejection fractions (LVEF) for planar (EFP) and SPECT (EFS) techniques. We reprojected the SPECT-RNV data along the best septal separation angle determined from planar scanning. This creates a further planar dataset denoted 'reprojected P-RNV' (rP-RNV) giving a reprojected ejection fraction (EFR) which can be used as a validation variable in transitioning to SPECT-only acquisition. RESULTS: Performing t tests showed no statistical difference between EFP and EFR (P > .017) but bias was observed in EFS results compared to EFP and EFS compared to EFR results. An unblinded, comparison of parametric data between the three datasets for a subset of ten patients showed good clinical concordance. False negative and false positive rates were low for rP-RNV compared to P-RNV. CONCLUSIONS: The reprojected planar LVEF correlates well to P-RNV EF values. The rP-RNV dataset can aid clinicians in transitioning from planar RNV to SPECT-only acquisition.


Assuntos
Algoritmos , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Ventriculografia com Radionuclídeos/métodos , Volume Sistólico , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Disfunção Ventricular Esquerda/diagnóstico por imagem , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Adulto Jovem
10.
Clin Imaging ; 108: 110081, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38340435

RESUMO

We compared image quality of head and neck CT angiography (CTA) obtained with a photon-counting detector CT (PCD-CT), including virtual monoenergetic images and polyenergetic reconstructions, and conventional energy-integrating detectors CT (EID-CT) in three patients. PCD-CT monoenergetic reconstructions at 70 keV and lower provided excellent image quality, with improved signal-to-noise and contrast-to-noise compared to EID-CT and PCD-CT polyenergetic reconstructions. PCD-CT may enable radiation dose and iodinated contrast dose reduction for cerebrovascular imaging.


Assuntos
Angiografia por Tomografia Computadorizada , Tomografia Computadorizada por Raios X , Humanos , Angiografia por Tomografia Computadorizada/métodos , Tomografia Computadorizada por Raios X/métodos , Meios de Contraste , Cabeça/diagnóstico por imagem , Pescoço/diagnóstico por imagem , Imagens de Fantasmas
11.
Phys Med ; 117: 103192, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38052710

RESUMO

Absorbed radiation doses are essential in assessing the effects, e.g. safety and efficacy, of radiopharmaceutical therapy (RPT). Patient-specific absorbed dose calculations in the target or the organ at risk require multiple inputs. These include the number of disintegrations in the organ, i.e. the time-integrated activities (TIAs) of the organs, as well as other parameters describing the process of radiation energy deposition in the target tissue (i.e. mean energy per disintegration, radiation dose constants, etc). TIAs are then estimated by incorporating the area under the radiopharmaceutical's time-activity curve (TAC), which can be obtained by quantitative measurements of the biokinetics in the patient (typically based on imaging data such as planar scintigraphy, SPECT/CT, PET/CT, or blood and urine samples). The process of TAC determination/calculation for RPT generally depends on the user, e.g., the chosen number and schedule of measured time points, the selection of the fit function, the error model for the data and the fit algorithm. These decisions can strongly affect the final TIA values and thus the accuracy of calculated absorbed doses. Despite the high clinical importance of the TIA values, there is currently no consensus on processing time-activity data or even a clear understanding of the influence of uncertainties and variations in personalised RPT dosimetry related to user-dependent TAC calculation. As a first step towards minimising site-dependent variability in RPT dosimetry, this work provides an overview of quality assurance and uncertainty management considerations of the TIA estimation.


Assuntos
Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Compostos Radiofarmacêuticos , Humanos , Compostos Radiofarmacêuticos/uso terapêutico , Tomografia Computadorizada com Tomografia Computadorizada de Emissão de Fóton Único , Radiometria/métodos , Cintilografia
12.
J Thorac Imaging ; 39(2): 93-100, 2024 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-37889562

RESUMO

PURPOSE: To evaluate a novel deep learning (DL)-based automated coronary labeling approach for structured reporting of coronary artery disease according to the guidelines of the Society of Cardiovascular Computed Tomography (CT) on coronary CT angiography (CCTA). PATIENTS AND METHODS: A retrospective cohort of 104 patients (60.3 ± 10.7 y, 61% males) who had undergone prospectively electrocardiogram-synchronized CCTA were included. Coronary centerlines were automatically extracted, labeled, and validated by 2 expert readers according to Society of Cardiovascular CT guidelines. The DL algorithm was trained on 706 radiologist-annotated cases for the task of automatically labeling coronary artery centerlines. The architecture leverages tree-structured long short-term memory recurrent neural networks to capture the full topological information of the coronary trees by using a two-step approach: a bottom-up encoding step, followed by a top-down decoding step. The first module encodes each sub-tree into fixed-sized vector representations. The decoding module then selectively attends to the aggregated global context to perform the local assignation of labels. To assess the performance of the software, percentage overlap was calculated between the labels of the algorithm and the expert readers. RESULTS: A total number of 1491 segments were identified. The artificial intelligence-based software approach yielded an average overlap of 94.4% compared with the expert readers' labels ranging from 87.1% for the posterior descending artery of the right coronary artery to 100% for the proximal segment of the right coronary artery. The average computational time was 0.5 seconds per case. The interreader overlap was 96.6%. CONCLUSIONS: The presented fully automated DL-based coronary artery labeling algorithm provides fast and precise labeling of the coronary artery segments bearing the potential to improve automated structured reporting for CCTA.


Assuntos
Doença da Artéria Coronariana , Estenose Coronária , Aprendizado Profundo , Masculino , Humanos , Feminino , Angiografia por Tomografia Computadorizada/métodos , Inteligência Artificial , Estudos Retrospectivos , Angiografia Coronária/métodos , Tomografia Computadorizada por Raios X/métodos , Doença da Artéria Coronariana/diagnóstico por imagem
13.
Eur J Radiol ; 176: 111517, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38805884

RESUMO

PURPOSE: To assess the impact of different quantum iterative reconstruction (QIR) levels on objective and subjective image quality of ultra-high resolution (UHR) coronary CT angiography (CCTA) images and to determine the effect of strength levels on stenosis quantification using photon-counting detector (PCD)-CT. METHOD: A dynamic vessel phantom containing two calcified lesions (25 % and 50 % stenosis) was scanned at heart rates of 60, 80 and 100 beats per minute with a PCD-CT system. In vivo CCTA examinations were performed in 102 patients. All scans were acquired in UHR mode (slice thickness0.2 mm) and reconstructed with four different QIR levels (1-4) using a sharp vascular kernel (Bv64). Image noise, signal-to-noise ratio (SNR), sharpness, and percent diameter stenosis (PDS) were quantified in the phantom, while noise, SNR, contrast-to-noise ratio (CNR), sharpness, and subjective quality metrics (noise, sharpness, overall image quality) were assessed in patient scans. RESULTS: Increasing QIR levels resulted in significantly lower objective image noise (in vitro and in vivo: both p < 0.001), higher SNR (both p < 0.001) and CNR (both p < 0.001). Sharpness and PDS values did not differ significantly among QIRs (all pairwise p > 0.008). Subjective noise of in vivo images significantly decreased with increasing QIR levels, resulting in significantly higher image quality scores at increasing QIR levels (all pairwise p < 0.001). Qualitative sharpness, on the other hand, did not differ across different levels of QIR (p = 0.15). CONCLUSIONS: The QIR algorithm may enhance the image quality of CCTA datasets without compromising image sharpness or accurate stenosis measurements, with the most prominent benefits at the highest strength level.


Assuntos
Angiografia por Tomografia Computadorizada , Angiografia Coronária , Estenose Coronária , Imagens de Fantasmas , Fótons , Razão Sinal-Ruído , Humanos , Angiografia por Tomografia Computadorizada/métodos , Masculino , Feminino , Angiografia Coronária/métodos , Estenose Coronária/diagnóstico por imagem , Pessoa de Meia-Idade , Idoso , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Reprodutibilidade dos Testes , Algoritmos
14.
Diagnostics (Basel) ; 14(9)2024 Apr 23.
Artigo em Inglês | MEDLINE | ID: mdl-38732280

RESUMO

This study evaluated a deep neural network (DNN) algorithm for automated aortic diameter quantification and aortic dissection detection in chest computed tomography (CT). A total of 100 patients (median age: 67.0 [interquartile range 55.3/73.0] years; 60.0% male) with aortic aneurysm who underwent non-enhanced and contrast-enhanced electrocardiogram-gated chest CT were evaluated. All the DNN measurements were compared to manual assessment, overall and between the following subgroups: (1) ascending (AA) vs. descending aorta (DA); (2) non-obese vs. obese; (3) without vs. with aortic repair; (4) without vs. with aortic dissection. Furthermore, the presence of aortic dissection was determined (yes/no decision). The automated and manual diameters differed significantly (p < 0.05) but showed excellent correlation and agreement (r = 0.89; ICC = 0.94). The automated and manual values were similar in the AA group but significantly different in the DA group (p < 0.05), similar in obese but significantly different in non-obese patients (p < 0.05) and similar in patients without aortic repair or dissection but significantly different in cases with such pathological conditions (p < 0.05). However, in all the subgroups, the automated diameters showed strong correlation and agreement with the manual values (r > 0.84; ICC > 0.9). The accuracy, sensitivity and specificity of DNN-based aortic dissection detection were 92.1%, 88.1% and 95.7%, respectively. This DNN-based algorithm enabled accurate quantification of the largest aortic diameter and detection of aortic dissection in a heterogenous patient population with various aortic pathologies. This has the potential to enhance radiologists' efficiency in clinical practice.

15.
Int J Cardiol ; 399: 131684, 2024 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-38151162

RESUMO

BACKGROUND: Coronary computed tomography angiography (CCTA)-based fractional flow reserve (CT-FFR) allows for noninvasive determination of the functional severity of anatomic lesions in patients with coronary artery disease. The aim of this study was to intra-individually compare CT-FFR between photon-counting detector (PCD) and conventional energy-integrating detector (EID) CT systems. METHODS: In this single-center prospective study, subjects who underwent clinically indicated CCTA on an EID-CT system were recruited for a research CCTA on PCD-CT within 30 days. Image reconstruction settings were matched as closely as possible between EID-CT (Bv36 kernel, iterative reconstruction strength level 3, slice thickness 0.5 mm) and PCD-CT (Bv36 kernel, quantum iterative reconstruction level 3, virtual monoenergetic level 55 keV, slice thickness 0.6 mm). CT-FFR was measured semi-automatically using a prototype on-site machine learning algorithm by two readers. CT-FFR analysis was performed per-patient and per-vessel, and a CT-FFR ≤ 0.75 was considered hemodynamically significant. RESULTS: A total of 22 patients (63.3 ± 9.2 years; 7 women) were included. Median time between EID-CT and PCD-CT was 5.5 days. Comparison of CT-FFR values showed no significant difference and strong agreement between EID-CT and PCD-CT in the per-vessel analysis (0.88 [0.74-0.94] vs. 0.87 [0.76-0.93], P = 0.096, mean bias 0.02, limits of agreement [LoA] -0.14/0.19, r = 0.83, ICC = 0.92), and in the per-patient analysis (0.81 [0.60-0.86] vs. 0.76 [0.64-0.86], P = 0.768, mean bias 0.02, LoA -0.15/0.19, r = 0.90, ICC = 0.93). All included patients were classified into the same category (CT-FFR > 0.75 vs ≤0.75) with both CT systems. CONCLUSIONS: CT-FFR evaluation is feasible with PCD-CT and it shows a strong agreement with EID-CT-based evaluation when images are similarly reconstructed.


Assuntos
Angiografia por Tomografia Computadorizada , Reserva Fracionada de Fluxo Miocárdico , Humanos , Feminino , Angiografia por Tomografia Computadorizada/métodos , Estudos Prospectivos , Tomografia Computadorizada por Raios X/métodos , Angiografia Coronária/métodos , Imagens de Fantasmas
16.
Skin Res Technol ; 19(4): 368-74, 2013 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-23551145

RESUMO

BACKGROUND: In tissue viability imaging (TiVi), an assessment method for skin erythema, correct orientation of skin position from provocation to assessment optimizes data interpretation. Image processing algorithms could compensate for the effects of skin translation, torsion and rotation realigning assessment images to the position of the skin at provocation. METHODS: A reference image of a divergent, UVB phototest was acquired, as well as test images at varying levels of translation, rotation and torsion. Using 12 skin markers, an algorithm was applied to restore the distorted test images to the reference image. RESULTS: The algorithm corrected torsion and rotation up to approximately 35 degrees. The radius of the erythemal reaction and average value of the input image closely matched that of the reference image's 'true value'. CONCLUSION: The image 'de-warping' procedure improves the robustness of the response image evaluation in a clinical research setting and opens the possibility of the correction of possibly flawed images performed away from the laboratory setting by the subject/patient themselves. This opportunity may increase the use of photo-testing and, by extension, other late response skin testing where the necessity of a return assessment visit is a disincentive to performance of the test.


Assuntos
Eritema/patologia , Processamento de Imagem Assistida por Computador/métodos , Processamento de Imagem Assistida por Computador/normas , Espectroscopia Fotoeletrônica/métodos , Espectroscopia Fotoeletrônica/normas , Sobrevivência de Tecidos , Adulto , Algoritmos , Feminino , Antebraço , Voluntários Saudáveis , Humanos , Masculino , Pessoa de Meia-Idade , Modelos Biológicos , Reprodutibilidade dos Testes , Pele/patologia
17.
Tomography ; 9(5): 1876-1902, 2023 10 17.
Artigo em Inglês | MEDLINE | ID: mdl-37888741

RESUMO

Imaging biomarkers (IBs) have been proposed in medical literature that exploit images in a quantitative way, going beyond the visual assessment by an imaging physician. These IBs can be used in the diagnosis, prognosis, and response assessment of several pathologies and are very often used for patient management pathways. In this respect, IBs to be used in clinical practice and clinical trials have a requirement to be precise, accurate, and reproducible. Due to limitations in imaging technology, an error can be associated with their value when considering the entire imaging chain, from data acquisition to data reconstruction and subsequent analysis. From this point of view, the use of IBs in clinical trials requires a broadening of the concept of quality assurance and this can be a challenge for the responsible medical physics experts (MPEs). Within this manuscript, we describe the concept of an IB, examine some examples of IBs currently employed in clinical practice/clinical trials and analyze the procedure that should be carried out to achieve better accuracy and reproducibility in their use. We anticipate that this narrative review, written by the components of the EFOMP working group on "the role of the MPEs in clinical trials"-imaging sub-group, can represent a valid reference material for MPEs approaching the subject.


Assuntos
Diagnóstico por Imagem , Humanos , Biomarcadores , Prognóstico , Reprodutibilidade dos Testes , Ensaios Clínicos como Assunto
18.
Eur J Radiol ; 161: 110746, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-36821957

RESUMO

PURPOSE: To investigate the effect of using photon-counting detector (PCD)-CT with ultra-high resolution (UHR) on stenosis quantification accuracy and blooming artifacts from low to high heart rates in a dynamic motion phantom. METHOD: Two vessel phantoms (diameter: 4 mm) containing solid calcified lesions (25%, 50% stenoses), filled with different concentrations of iodine, inside an anthropomorphic thorax phantom attached to a coronary motion simulator were used. Scanning was performed on a PCD-CT system using an ECG-gated mode at UHR and standard resolution (SR) (0.2, 0.6 mm slice thickness, respectively). Images were reconstructed at 60, 80 and 100 beats per minute (bpm) (UHR: Bv56 kernel, quantum iterative reconstruction (QIR) level 3; SR: 55 keV, Bv40 kernel, QIR3). Percent diameter stenosis (PDS) and blooming artifacts were measured by two readers. RESULTS: PDS measurements derived from UHR were more accurate than SR for both lesions at every heart rate (p ≤ 0.005 for all, e.g. 50% lesion SR vs. UHR: at 60 bpm 57.1% [55.2-59.2] vs. 50.0% [48.5-51.2], at 100 bpm 61.0% [58.6-64.3] vs. 52.4% [51.3-54.3]). Overall mean difference across heart rates and lesions compared to the nominal stenoses was 9.2% (Limit of Agreement (LoA), 2.4%/16.0%) for SR vs. 2.4% (LoA, -2.8%/7.5%) for UHR. Blooming artifacts decreased with UHR compared to SR for both lesions at every heart rate (p < 0.001 for all, e.g. 50% lesion SR vs. UHR: at 60 bpm 63.8% [60.6-69.5] vs. 52.5% [50.0-57.5], at 100 bpm 70.2% [64.8-78.1] vs. 56.1% [51.2-60.8]). CONCLUSIONS: This motion phantom study demonstrates improved stenosis quantification accuracy and reduced blooming artifacts with UHR-PCD-CT compared to SR, independent of heart rate.


Assuntos
Angiografia por Tomografia Computadorizada , Estenose Coronária , Humanos , Constrição Patológica , Frequência Cardíaca , Tomografia Computadorizada por Raios X/métodos , Angiografia Coronária/métodos , Estenose Coronária/diagnóstico por imagem , Imagens de Fantasmas , Tórax
19.
Invest Radiol ; 58(9): 673-680, 2023 09 01.
Artigo em Inglês | MEDLINE | ID: mdl-36822677

RESUMO

OBJECTIVES: The aim of this study was to evaluate the impact of virtual monoenergetic imaging (VMI) and quantum iterative reconstruction (QIR) on the accuracy of coronary artery calcium scoring (CACS) using a virtual noniodine (VNI) reconstruction algorithm on a first-generation, clinical, photon counting detector computed tomography system. MATERIALS AND METHODS: Coronary artery calcium scoring was evaluated in an anthropomorphic chest phantom simulating 3 different patient sizes by using 2 extension rings (small: 300 × 200 mm, medium: 350 × 250 mm, large: 400 × 300 mm) and in patients (n = 61; final analyses only in patients with coronary calcifications [n = 34; 65.4 ± 10.0 years; 73.5% male]), who underwent nonenhanced and contrast-enhanced, electrocardiogram-gated, cardiac computed tomography on a photon counting detector system. Phantom and patient data were reconstructed using a VNI reconstruction algorithm at different VMI (55-80 keV) and QIR (strength 1-4) levels (CACS VNI ). True noncontrast (TNC) scans at 70 keV and QIR "off" were used as reference for phantom and patient studies (CACS TNC ). RESULTS: In vitro and in vivo CACS VNI showed strong correlation ( r > 0.9, P < 0.001 for all) and excellent agreement (intraclass correlation coefficient > 0.9 for all) with CACS TNC at all investigated VMI and QIR levels. Phantom and patient CACS VNI significantly increased with decreasing keV levels (in vitro: from 475.2 ± 26.3 at 80 keV up to 652.5 ± 42.2 at 55 keV; in vivo: from 142.5 [7.4/737.7] at 80 keV up to 248.1 [31.2/1144] at 55 keV; P < 0.001 for all), resulting in an overestimation of CACS VNI at 55 keV compared with CACS TNC at 70 keV in some cases (in vitro: 625.8 ± 24.4; in vivo: 225.4 [35.1/959.7]). In vitro CACS increased with rising QIR at low keV. In vivo scores were significantly higher at QIR 1 compared with QIR 4 only at 60 and 80 keV (60 keV: 220.3 [29.6-1060] vs 219.5 [23.7/1048]; 80 keV: 152.0 [12.0/735.6] vs 142.5 [7.4/737.7]; P < 0.001). CACS VNI was closest to CACS TNC at 60 keV, QIR 2 (+0.1%) in the small; 55 keV, QIR 1 (±0%) in the medium; 55 keV, QIR 4 (-0.1%) in the large phantom; and at 60 keV, QIR 1 (-2.3%) in patients. CONCLUSIONS: Virtual monoenergetic imaging reconstructions have a significant impact on CACS VNI . The effects of different QIR levels are less consistent and seem to depend on several individual conditions, which should be further investigated.


Assuntos
Cálcio , Vasos Coronários , Humanos , Masculino , Feminino , Razão Sinal-Ruído , Vasos Coronários/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Algoritmos
20.
Eur J Radiol ; 166: 111008, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37542817

RESUMO

PURPOSE: To intra-individually compare the objective and subjective image quality of coronary computed tomography angiography (CCTA) between photon-counting detector CT (PCD-CT) and energy-integrating detector CT (EID-CT). METHOD: Consecutive patients undergoing clinically indicated CCTA on an EID-CT system were prospectively enrolled for a research CCTA performed on a PCD-CT system within 30 days. Polychromatic images were reconstructed for both EID- and PCD-CT, while virtual monoenergetic images (VMI) were generated at 40, 45, 50, 55, 60 and 70 keV for PCD-CT. Two blinded readers calculated contrast-to-noise ratio (CNR) for each major coronary artery and rated image noise, vessel attenuation, vessel sharpness, and overall quality on a 1-5 Likert scale. Patients were then stratified by body mass index (BMI) [high (>30 kg/m2) vs low (<30 kg/m2)] for subgroup analysis. RESULTS: A total of 20 patients (67.5 ± 9.0 years, 75% male) were included in the study. Compared with EID-CT, coronary artery CNR values from PCD-CT monoenergetic and polychromatic reconstructions were all significantly higher than CNR values from EID-CT, with incrementally greater differences in obese subjects (all p < 0.008). Subjective image noise and sharpness were also significantly higher for all VMI reconstructions compared to EID-CT (all p < 0.008). All subjective scores were significantly higher for 55, 60, and 70 keV PCD-CT than EID-CT values (all p < 0.05). CONCLUSIONS: The improved objective and subjective image quality of PCD-CT compared to EID-CT may provide better visualization of the coronary arteries for a wide array of patients, especially those with a high BMI.


Assuntos
Vasos Coronários , Tomografia Computadorizada por Raios X , Humanos , Masculino , Feminino , Vasos Coronários/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Angiografia por Tomografia Computadorizada/métodos , Coração , Fótons , Imagens de Fantasmas
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa