Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 57
Filtrar
1.
J Zoo Wildl Med ; 50(2): 295-302, 2019 Jun 13.
Artigo em Inglês | MEDLINE | ID: mdl-31260192

RESUMO

Conservation efforts determining the health status of individuals can aid in assessing population health and sustainability. Body condition was determined in 65 free-ranging Eastern box turtles (Terrapene carolina carolina) from four locations in Vermilion County, Illinois, in the months of May, July, and September 2014, 2015, and 2016 using computed tomography (CT). Physical examinations were performed to determine morphometric measurements, and CT scans measured body fat. Twenty-three linear models were constructed to determine which morphometric measurements best correlated to fat content. The top two models of body fat included a relationship between mass and carapace width. Fat increases as both mass and carapace width increase. CT, while impractical for daily use, improved on previous methods of measuring body condition and created a calculation that can be applied broadly to Eastern box turtles. By understanding how measurements of mass and carapace width correlate to body condition, practitioners, researchers, and conservationists can evaluate chelonians with increased confidence in the accuracy of their assessment.


Assuntos
Tomografia Computadorizada por Raios X/veterinária , Tartarugas/fisiologia , Animais , Animais Selvagens , Composição Corporal , Feminino , Masculino , Estações do Ano , Fatores de Tempo
2.
Vet Radiol Ultrasound ; 59(4): 412-422, 2018 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-29659090

RESUMO

Arterial thromboembolism is a life-threatening condition in cats most commonly secondary to cardiac disease. Echocardiography is the reference standard to evaluate for presence of a thrombus. In humans, computed tomographic (CT) angiography is becoming widely used to detect left atrial thrombi precluding the use of sedation. The purpose of this prospective, controlled, methods comparison pilot study was threefold: (1) describe new CT angiography protocol used in awake cats with cardiac disease and congestive heart failure; (2) determine accuracy of continuous and dynamic acquisition CT angiography to identify and characterize cardiac thrombi from spontaneous echocardiographic contrast using transthoracic echocardiography as our reference standard; (3) identify known negative prognostic factors and comorbidities of the thorax that CT angiography may provide that complement or supersede echocardiographic examination. Fourteen cats with heart disease were recruited; 7 with thrombi and 7 with spontaneous echocardiographic contrast. Echocardiography and awake CT angiography were performed using a microdose of contrast. Six of 7 thrombi were identified on CT angiography as filling defects by at least one reviewer within the left auricle (n = 6) and right heart (n = 1). Highest sensitivity (71.4%) was in continuous phase and highest specificity (85.7%) was in dynamic studies with fair to moderate interobserver agreement (0.38 and 0.44). CT angiography identified prognostic cardiac information (left atrial enlargement, congestive heart failure, arterial thromboembolism) and comorbidities (suspected idiopathic pulmonary fibrosis, asthma). This study indicates CT angiography can readily identify cardiac thrombi, important prognostic information and comorbidities, and can be safely performed in cats with cardiac disease and congestive heart failure.


Assuntos
Doenças do Gato/diagnóstico por imagem , Angiografia por Tomografia Computadorizada/veterinária , Cardiopatias/veterinária , Animais , Gatos , Comorbidade , Angiografia por Tomografia Computadorizada/métodos , Cardiopatias/diagnóstico por imagem , Insuficiência Cardíaca/diagnóstico por imagem , Insuficiência Cardíaca/veterinária , Projetos Piloto , Prognóstico , Estudos Prospectivos , Sensibilidade e Especificidade , Tórax/diagnóstico por imagem
3.
Vet Radiol Ultrasound ; 56(4): 417-24, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-25857430

RESUMO

Abnormalities of the deep digital flexor tendon, navicular bone, and collateral sesamoidean ligament can be difficult to visualize using magnetic resonance imaging (MRI) if bursal fluid is absent. The use of saline podotrochlear bursography improves podotrochlear apparatus evaluation, however, the technique has disadvantages. The objective of this prospective feasibility study was to describe saline arthrography of the distal interphalangeal joint as an alternative technique for improving MRI visualization of the deep digital flexor tendon, navicular bone, collateral sesamoidean ligament, and podotrochlear bursa, and to compare this technique with saline podotrochlear bursography. Eight paired cadaver forelimbs were sampled. Saline podotrochlear bursography or saline arthrography techniques were randomly assigned to one limb, with the alternate technique performed on the contralateral limb. For precontrast and postcontrast studies using each technique, independent observers scored visualization of the dorsal aspect of the deep digital flexor tendon, palmar aspect of the navicular bone, collateral sesamoidean ligament, and podotrochlear bursa. Both contrast techniques improved visualization of structures over precontrast MR images and visualization scores for both techniques were similar. Findings from this study demonstrated that saline arthrography is feasible and comparable to saline podotrochlear bursography for producing podotrochlear bursa distension and separation of the structures of the podotrochlear apparatus on nonweight bearing limbs evaluated with low-field MRI. Clinical evaluation of saline arthrography on live animals is needed to determine if this technique is safe and effective as an alternative to saline podotrochlear bursography in horses with suspected pathology of the podotrochlear apparatus.


Assuntos
Artrografia/veterinária , Pé/diagnóstico por imagem , Membro Anterior/diagnóstico por imagem , Doenças dos Cavalos/diagnóstico por imagem , Animais , Bolsa Sinovial/diagnóstico por imagem , Cadáver , Ligamentos Colaterais/diagnóstico por imagem , Meios de Contraste , Estudos de Viabilidade , Cavalos , Imageamento por Ressonância Magnética/veterinária , Azul de Metileno , Estudos Prospectivos , Distribuição Aleatória , Cloreto de Sódio , Tendões/diagnóstico por imagem
4.
Rapid Commun Mass Spectrom ; 27(17): 1969-76, 2013 Sep 15.
Artigo em Inglês | MEDLINE | ID: mdl-23939964

RESUMO

RATIONALE: The addition of a dopant to an Atmospheric Pressure PhotoIonization (APPI) source of a mass spectrometer has been shown to enhance the degree of analyte ionization. A series of different dopants has been successfully utilized; however, there has been very little published on the characteristics of a good dopant. We have proposed carbon disulfide (CS2) as a novel new dopant based on its absorption cross-section for the VUV photon's energy used and its unique gas-phase ion chemistry, notably the fact that it does not contain a proton. METHODS: The ability of CS2 to enhance the ionization effectiveness of APPI was tested by using a group of compounds that have different proton affinities (PAs) and electron affinities (EAs). These results were compared to results obtained using the commonly used dopants, toluene and anisole. Particular attention was paid to the formation of [M](+) ions relative to [M+H](+) ions. Mass spectra were collected using a Waters Quattro Premier liquid chromatography/tandem mass spectrometry (LC/MS/MS) system equipped with a commercial Photomate™ photoionization source. RESULTS: The results show that CS2 increases the ionization efficiency of most of the analytes studied in this work comparably to toluene and anisole. CS2 promotes both ionization routes of [M](+) and [M+H](+). In addition, due to the higher ionization energy (IE) of CS2 (10.01) compared to the IEs of toluene (8.83) and anisole (8.20), CS2 can enhance the ionization efficiency of analytes that cannot be enhanced with toluene and anisole. CONCLUSIONS: We have determined that CS2 is a viable dopant for use in APPI sources. For some analytes, significant [M+H](+) ion signals are observed; therefore, the donated proton must come from either water clusters or solvents. In addition, CS2 promotes the ionization of analytes with low PAs and higher IEs than that of toluene and anisole.

5.
Vet Ophthalmol ; 16(5): 352-8, 2013 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-23998509

RESUMO

OBJECTIVE: To compare the diagnostic quality of computed tomography (CT) images of normal ocular and orbital structures acquired with and without the use of general anesthesia in the cat. ANIMAL STUDIED: Eleven privately owned cats with nasal disease presenting to a single referral hospital. PROCEDURES: All cats received a complete ophthalmic examination. A 16 multislice helical CT system was utilized to acquire images of the skull and neck with and without the use of general anesthesia. Images were acquired before and after the administration of intravenous iodinated contrast. Images of normal ocular and orbital structures were evaluated via consensus by two board-certified radiologists. Visibility of ocular and orbital structures, degree of motion, and streak artifact were assessed and scored for each image set in the transverse, dorsal, and sagittal planes. RESULTS: The use of general anesthesia did not significantly affect the diagnostic quality of images. No motion artifact was observed in any CT image. Streak artifact was significantly increased in scans performed in the transverse orientation but not in the dorsal orientation or sagittal orientation and did not affect the diagnostic quality of the images. Contrast enhancement did not significantly enhance the visibility of any ocular or orbital structures. CONCLUSION: Diagnostic CT images of normal ocular and orbital structures can be acquired without the use of general anesthesia in the cat.


Assuntos
Anestesia Geral/veterinária , Gatos/anatomia & histologia , Olho/diagnóstico por imagem , Órbita/diagnóstico por imagem , Tomografia Computadorizada por Raios X/veterinária , Animais , Olho/anatomia & histologia , Órbita/anatomia & histologia
6.
Vet Anaesth Analg ; 40(6): e48-56, 2013 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-23802592

RESUMO

OBJECTIVE: To evaluate the dexmedetomidine-induced reduction in organ blood flow with quantitative contrast-enhanced ultrasound (CEUS) method and to observe the influence of MK-467 on such reduction. STUDY DESIGN: Randomized cross-over study. ANIMALS: Six adult purpose-bred laboratory beagle dogs (mean body weight 15.3 ± 1.9 kg). METHODS: Contrast-enhanced ultrasound was performed on six conscious healthy laboratory beagles. The animals on separate occasions underwent three treatments: awake without any medication (CTRL), dexmedetomidine 10 µg kg(-1) (DEX) and DEX + MK-467 500 µg kg(-1) (DMK) intravenously (IV). The kidney (10-15 minutes post-treatment), spleen (25-30 minutes post-treatment), small intestine (40-45 minutes post-treatment) and liver (50-55 minutes post-treatment) were examined with CEUS. A time curve was generated and the following perfusion parameters were analysed: arrival time (AT), time to peak from injection (TTPinj), peak intensity (PI) and wash-in rate (Wi). In addition to CEUS, renal glomerular filtration rate was indirectly estimated by the rate of iohexol elimination. RESULTS: AT and TTPinj were significantly higher for DEX than for CTRL in all studied organs. The same parameters were significantly higher for DEX than for DMK in the kidney, spleen and small intestine. PI was significantly lower for DEX than for CTRL or DMK in the kidney. Wi was significantly lower for DEX than for CTRL or DMK in the kidney and significantly lower than for CTRL only in the small intestine. Plasma concentration of iohexol was significantly higher after DEX than CTRL administration. CONCLUSIONS: Contrast-enhanced ultrasound was effective in detecting DEX-induced changes in blood flow. MK-467 attenuated these changes. CLINICAL RELEVANCE: Clinicians should consider the effects of the sedation protocol when performing CEUS. Addition of MK-467 might beneficially impact the haemodynamic function of sedation with alpha-2 adrenoceptor agonists.


Assuntos
Agonistas de Receptores Adrenérgicos alfa 2/farmacologia , Dexmedetomidina/farmacologia , Hipnóticos e Sedativos/farmacologia , Quinolizinas/farmacologia , Fluxo Sanguíneo Regional/efeitos dos fármacos , Anestesia por Inalação/métodos , Anestesia por Inalação/veterinária , Animais , Meios de Contraste , Cães , Feminino , Intestino Delgado/irrigação sanguínea , Iohexol , Rim/irrigação sanguínea , Fígado/irrigação sanguínea , Masculino , Baço/irrigação sanguínea , Ultrassonografia/métodos , Ultrassonografia/veterinária
7.
Vet Radiol Ultrasound ; 54(6): 591-604, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-23919809

RESUMO

Contrast-enhanced multi-detector computed tomography (CE-MDCT) is used routinely in evaluating human patients with acute abdominal symptoms. Contrast-enhanced ultrasound (CEUS) continues to be in its infancy as it relates to evaluation of the acute abdomen. The purpose of this study was to compare survey radiography, B-mode ultrasound, CEUS, and CE-MDCT findings in canine patients presenting with acute abdominal signs; with a focus on the ability to differentiate surgical from non-surgical conditions. Nineteen dogs were prospectively enrolled. Inclusion required a clinical diagnosis of acute abdominal signs and confirmed surgical or non-surgical causes for the clinical signs. Agreement for the majority of recorded imaging features was at least moderate. There was poor agreement in the identification of pneumoperitoneum and in the comparison of pancreatic lesion dimensions for B-mode vs. CEUS. The CT feature of fat stranding was detected in cases including, but not limited to, gastric neoplasia with perforation, pancreatitis, and small intestinal foreign body. Ultrasound underestimated the size and number of specific lesions when compared with CE-MDCT. Contrast-enhanced ultrasound was successful in detecting bowel and pancreatic perfusion deficits that CE-MDCT failed to identify. Accuracy for differentiation of surgical vs. non-surgical conditions was high for all modalities; 100%, 94%, and 94% for CE-MDCT, ultrasonography and survey radiography respectively. Findings indicated that CE-MDCT is an accurate screening test for differentiating surgical from non-surgical acute abdominal conditions in dogs. Focused CEUS following CE-MDCT or B-mode ultrasonography may be beneficial for identifying potentially significant hypoperfused lesions.


Assuntos
Abdome Agudo/veterinária , Doenças do Cão/diagnóstico por imagem , Tomografia Computadorizada Multidetectores/veterinária , Ultrassonografia/veterinária , Abdome/diagnóstico por imagem , Abdome Agudo/diagnóstico por imagem , Abdome Agudo/patologia , Animais , Doenças do Cão/patologia , Cães , Feminino , Masculino , Estudos Prospectivos , Radiografia Abdominal/veterinária , Sensibilidade e Especificidade
8.
Games Health J ; 11(2): 79-84, 2022 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-35049380

RESUMO

Objective: Game-based interventions can easily disseminate health information to hard-to-reach populations, such as sexual and gender minority youth (SGMY; e.g., gay/lesbian, bisexual, and transgender youth). SGMY disproportionately experience health problems, which have been attributed to greater violence victimization, such as bullying. Nevertheless, few interventions exist to improve health outcomes for bullied SGMY. Since game-based interventions offer economically viable and easily scalable solutions, we explored why bullied SGMY play games, the gaming characteristics they enjoy, and their preferences for future game-based interventions. Materials and Methods: We conducted semistructured qualitative interviews with 20 14- to 18-year-old U.S.-residing bullied SGMY recruited from social media. We asked participants about their current gaming experiences, preferences, and suggestions for future games and then conducted thematic analysis. Results: The majority of SGMY reported playing games to experience positive feelings associated with higher degrees of agency. Through controlling in-game storyline and character customization settings, SGMY described feeling safe and engaged in game play. In addition, SGMY reported playing games as a distraction from the real world. Coping with stress and other negative emotions was a commonly reported motivation for playing games, as was gleaning happiness independent from stress management. Furthermore, SGMY mentioned using games to connect with people, both in-person and virtually, to develop and maintain friendships. Conclusion: This study highlights specific methods of tailoring games to the interests of bullied SGMY. In addition, our findings are preliminary indicators that SGMY may use games to achieve healthy psychosocial developmental milestones. This study may be integral in informing the development of future game-based interventions for SGMY.


Assuntos
Bullying , Minorias Sexuais e de Gênero , Jogos de Vídeo , Adolescente , Feminino , Humanos , Motivação , Pesquisa Qualitativa
9.
J Vet Intern Med ; 35(3): 1509-1518, 2021 May.
Artigo em Inglês | MEDLINE | ID: mdl-33811698

RESUMO

BACKGROUND: The origin of cough in dogs with heart murmurs is controversial, because the cough could be primary cardiac (eg, pulmonary edema, bronchi compression by left-sided cardiomegaly) or respiratory (eg, bronchomalacia, other bronchial or bronchiolar disease, interstitial lung disease) in origin. HYPOTHESIS/OBJECTIVES: To study the association between left atrium (LA) dilatation and cardiomegaly and bronchial narrowing in coughing dogs with heart murmurs using computed tomography (CT). ANIMALS: Twenty-one client-owned coughing dogs with heart murmurs and 14 historical control dogs. METHODS: Dogs with cough and murmur were prospectively recruited over 4 months. Cervical and thoracic radiography, echocardiography, and thoracic CT were performed in enrolled dogs. Control dogs, with no disease on thoracic CT and no records of heart murmur and coughing, were gathered from the institution's computerized database. Degree of bronchial narrowing was assessed using the bronchial-to-aorta (Ao) ratio, measured by 3 radiologists blinded to the clinical findings. After identifying bronchi that were significantly narrowed in dogs with murmur compared to controls, the relationship between degree of narrowing and LA/Ao ratio (measured echocardiographically) and vertebral heart scale (VHS) measured radiographically was studied in dogs with murmur using mixed-effects regression. RESULT: Significant narrowing was identified for all left-sided bronchi and the right principal, middle, and caudal bronchi in the coughing dogs, compared with controls. Increasing LA size and VHS were significantly inversely associated with diameter for all left-sided and right-sided bronchi indicated above. CONCLUSION AND CLINICAL IMPORTANCE: Results indicate an association between LA enlargement and cardiomegaly and bronchial narrowing and support heart size-associated exacerbation of cough in dogs with murmurs.


Assuntos
Tosse , Doenças do Cão , Animais , Brônquios/diagnóstico por imagem , Tosse/diagnóstico por imagem , Tosse/veterinária , Doenças do Cão/diagnóstico por imagem , Cães , Sopros Cardíacos/diagnóstico por imagem , Sopros Cardíacos/etiologia , Sopros Cardíacos/veterinária , Tomografia Computadorizada por Raios X/veterinária
10.
Am J Vet Res ; 71(11): 1305-11, 2010 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-21034321

RESUMO

OBJECTIVE: To evaluate perfusion of abdominal organs in healthy cats by use of contrast-enhanced ultrasonography. ANIMALS: 10 young healthy anesthetized cats. PROCEDURES: Contrast-enhanced ultrasonography of the liver, left kidney, pancreas, small intestine, and mesenteric lymph nodes was performed on anesthetized cats. RESULTS: Typical perfusion patterns were found for each of the studied organs. Differences in perfusion among organs were associated with specific physiologic features. The liver was enhanced gradually and had a more heterogeneous perfusion pattern because of its dual blood supply and close proximity to the diaphragm, compared with other organs. An obvious and significant difference in perfusion was detected between the renal cortex and medulla. No significant differences in perfusion were detected among the pancreas, small intestine, and mesenteric lymph nodes. CONCLUSIONS AND CLINICAL RELEVANCE: Results indicated that contrast-enhanced ultrasonography can be used in cats to estimate organ perfusion as in other species. Observed differences in perfusion variables can be mostly explained by physiologic differences in vascularity.


Assuntos
Intestino Delgado/diagnóstico por imagem , Rim/diagnóstico por imagem , Fígado/diagnóstico por imagem , Linfonodos/diagnóstico por imagem , Pâncreas/diagnóstico por imagem , Animais , Gatos , Aumento da Imagem , Intestino Delgado/fisiologia , Rim/fisiologia , Córtex Renal/diagnóstico por imagem , Medula Renal/diagnóstico por imagem , Fígado/fisiologia , Linfonodos/fisiologia , Microcirculação/fisiologia , Pâncreas/fisiologia , Perfusão , Valores de Referência , Ultrassonografia
11.
J Am Anim Hosp Assoc ; 46(3): 152-60, 2010.
Artigo em Inglês | MEDLINE | ID: mdl-20439937

RESUMO

The feline infectious peritonitis virus (FIPV) is a mutated form of the feline enteric coronavirus (FeCV) that can present with a variety of clinical signs. The purpose of this retrospective study was to analyze abdominal ultrasonographic findings associated with cats with confirmed FIPV infection. Sixteen cases were included in the study from a review of medical records at two academic institutions; inclusion was based either on necropsy lesions (n=13) or a combination of histopathological, cytological, and clinicopathological findings highly suggestive of FIPV infection (n=3). The liver was judged to be normal in echogenicity in 11 (69%) cats, diffusely hypoechoic in three cats, focally hyperechoic in one cat, and focally hypoechoic in one cat. Five cats had a hypoechoic subcapsular rim in one (n=3) or both (n=2) kidneys. Free fluid was present in the peritoneal cavity in seven cats and in the retroperitoneal space in one cat. Abdominal lymphadenopathy was noted in nine cats. The spleen was normal in echogenicity in 14 cats and was hypoechoic in two. One cat had bilateral orchitis with loss of normal testicular architecture. Although none of these ultrasonographic findings are specific for FIPV infection, a combination of these findings should increase the index of suspicion for FIPV infection when considered along with appropriate clinical signs.


Assuntos
Abdome/diagnóstico por imagem , Peritonite Infecciosa Felina/diagnóstico por imagem , Ultrassonografia/veterinária , Abdome/patologia , Animais , Gatos , Peritonite Infecciosa Felina/patologia , Feminino , Rim/diagnóstico por imagem , Rim/patologia , Rim/virologia , Fígado/diagnóstico por imagem , Fígado/patologia , Fígado/virologia , Masculino , Estudos Retrospectivos , Ultrassonografia/métodos
12.
J Vet Emerg Crit Care (San Antonio) ; 28(5): 429-435, 2018 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-29901282

RESUMO

OBJECTIVE: To determine the agreement between focused assessment with sonography for trauma (FAST) exams and computed tomography (CT) for the detection of pleural and peritoneal fluid and pneumothorax in animals that have sustained recent trauma. DESIGN: Prospective study. SETTING: University Teaching Hospital. ANIMALS: Thirteen dogs and 2 cats were enrolled into the study, with 10 having sustained blunt force trauma and 5 penetrating trauma. INTERVENTIONS: Abdominal FAST (AFAST) and thoracic FAST (TFAST) exams were performed by emergency room (ER) clinician or house officers and radiology house officers (radiology). TFAST evaluated for the presence of pneumothorax and pleural effusion, and AFAST evaluated for the presence of peritoneal effusion. A minimally sedated, full-body CT exam was performed on each patient and interpreted by a board-certified radiologist. The exams were performed in the same order for all patients: ER FAST, followed by radiology FAST, followed by CT, and operators were blinded to the results of the other exams. A kappa statistic was calculated to assess for agreement between the FAST exams and CT. MEASUREMENTS AND MAIN RESULTS: The median time to perform all 3 exams was 55 minutes (range 30-150 min). There was moderate to excellent agreement between AFAST and CT for detection of free peritoneal fluid (ER K = 0.82; radiology K = 0.53), fair to moderate agreement between TFAST and CT for detection of pleural free fluid (ER K = 0.53; radiology K = 0.36), and poor agreement between TFAST and CT for detection of pneumothorax (ER K = -0.06; radiology K = -0.12). CONCLUSIONS: FAST exams reliably identify the presence of free fluid in the peritoneal and pleural cavities; however, TFAST is not a reliable method to diagnose pneumothorax in dogs and cats following trauma.


Assuntos
Traumatismos Abdominais/veterinária , Doenças do Gato/diagnóstico por imagem , Doenças do Cão/diagnóstico por imagem , Ferimentos não Penetrantes/veterinária , Traumatismos Abdominais/diagnóstico por imagem , Animais , Gatos , Cães , Serviço Hospitalar de Emergência , Avaliação Sonográfica Focada no Trauma/veterinária , Valor Preditivo dos Testes , Estudos Prospectivos , Tomografia Computadorizada por Raios X/veterinária , Ultrassonografia/veterinária , Ferimentos não Penetrantes/diagnóstico por imagem
13.
Vet J ; 174(3): 501-12, 2007 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-17412620

RESUMO

The concept of contrast enhancement has significantly extended the usefulness of ultrasound imaging in human medicine and medical research over the past decade. The persistence and efficacy of ultrasound contrast agents has been improved and specific imaging sequences have been developed. Contrast ultrasound provides Doppler and grey-scale enhancement. Doppler examinations are improved when studying deep or small vessels and vessels with low flow velocities. Specific contrast imaging sequences allow detection of tissue enhancement with grey-scale ultrasound which enables assessment of tissue perfusion. Major clinical applications of contrast ultrasound in the human medicine field are the heart, the parenchymal organs such as the liver, spleen and kidneys, and vascular applications. Many other interesting applications have been identified and beside their diagnostic value, intensive research is currently investigating the use of ultrasound contrast agents for therapeutic applications such as targeted delivery of drug- or gene-loaded microbubbles. In the last few years, contrast ultrasound has also been introduced in veterinary medicine. Its usefulness has been shown in diseases of the liver, spleen, kidney, pancreas, lymph nodes and superficial tumours. In the present article, an overview of the physical principles, imaging techniques and image analyses is presented. In addition, a literature review details the current use in veterinary medicine and areas of potential utilization are discussed.


Assuntos
Meios de Contraste , Ultrassonografia/métodos , Ultrassonografia/veterinária , Doenças dos Animais/diagnóstico , Animais , Humanos
14.
J Am Anim Hosp Assoc ; 43(4): 179-86, 2007.
Artigo em Inglês | MEDLINE | ID: mdl-17615397

RESUMO

When performing abdominal ultrasonography in dogs, the right aspect of the liver, porta hepatis, right kidney, right adrenal gland, pancreas, and duodenum are often not fully visible from a ventral, or subcostal, approach. The right lateral intercostal plane is an alternative approach that allows evaluation of these structures. This report provides multiple case examples that demonstrate the sonographic anatomy via the right intercostal approach. Other cases are included to demonstrate indications for this approach. Animals in which the right intercostal approach may prove most useful include large- and giant-breed dogs; deep-chested dogs; dogs with gas distention of the stomach, duodenum, and colon; dogs with microhepatia; and those with abdominal effusion and pain.


Assuntos
Doenças do Cão/diagnóstico por imagem , Ultrassonografia/veterinária , Animais , Diagnóstico Diferencial , Cães , Postura , Ultrassonografia/métodos , Ultrassonografia/normas
15.
Clin Tech Small Anim Pract ; 22(3): 93-103, 2007 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-17844815

RESUMO

Technical improvements have made profound changes in diagnostic ultrasound imaging. Some of these changes, such as encoded pulses and receive focusing, occur in the background and are essentially nonadjustable. Others, including harmonics and compounding, are real-time options and are adjustable by the imager. New technologies that offer great promise for improved characterization of lesions include contrast ultrasound and elastography. This article will attempt to update the small animal imager on the clinical applications of these newer technologies.


Assuntos
Doenças dos Animais/diagnóstico por imagem , Ultrassonografia/veterinária , Doenças dos Animais/diagnóstico , Animais , Diagnóstico Diferencial , Processamento de Imagem Assistida por Computador , Imageamento Tridimensional , Processamento de Sinais Assistido por Computador , Transdutores , Ultrassonografia/instrumentação , Ultrassonografia/métodos , Ultrassonografia/tendências
16.
Clin Tech Small Anim Pract ; 22(3): 128-37, 2007 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-17844819

RESUMO

Ultrasound can be used to detect and evaluate both normal and abnormal lymph nodes, as well as aid in biopsy sampling procedures, an important part of staging procedures in cancer patients. Several parameters can be evaluated using ultrasound; lymph node size, margins, echogenicity, echopattern (echotexture), acoustic transmission, presence and distribution of vascular flow, and vascular flow indices. The most diagnostically helpful include the short/long axis ratio of the lymph node, the pattern of distribution of the blood vessels within the lymph node, and to some extent the resistive and pulsatility indices. This review discusses the use of ultrasound for detecting, evaluating, and sampling peripheral, abdominal and thoracic lymph nodes in small animals.


Assuntos
Doenças do Cão/diagnóstico por imagem , Linfonodos/diagnóstico por imagem , Ultrassonografia Doppler em Cores/veterinária , Animais , Doenças do Cão/diagnóstico , Cães , Linfonodos/anatomia & histologia , Metástase Linfática/diagnóstico , Metástase Linfática/diagnóstico por imagem , Biópsia de Linfonodo Sentinela/métodos , Biópsia de Linfonodo Sentinela/veterinária , Ultrassonografia Doppler em Cores/métodos
17.
J Zoo Wildl Med ; 38(2): 222-30, 2007 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-17679505

RESUMO

Iron overload was induced by iron dextran i.v. in clinically healthy adult pigeons, Columbia livia, (n = 8). Hemosiderosis was induced in all treated birds. Two control pigeons received no iron injections. Pigeons did not show clinical signs of iron overload during the 6-wk study. Ultrasound examination of the liver in the pigeons receiving iron dextran was performed on days 0, 13, 28, and 42. No ultrasound images were collected on the control pigeons. Magnetic resonance imaging was performed on days 0, 13, 28, and 42 on all study pigeons and imaging sequences were collected in three different imaging formats: T1, T2, and gradient-recalled echo (GRE). Surgical liver biopsies were performed on pigeons receiving iron dextran on days 2, 16, and 45 (at necropsy). A single liver sample was collected at necropsy from the control birds. Histologic examination, quantitative image analysis, and tissue iron analysis by thin-layer chromatography were performed on each liver sample and compared to the imaging studies. Although hemosiderosis was confirmed histologically in each experimental pigeon, no significant change in pixel intensity of the ultrasound images was seen at any point in the study. Signal intensity, in all magnetic resonance imaging formats, significantly decreased in a linear fashion as the accumulation of iron increased.


Assuntos
Doenças das Aves/diagnóstico , Columbidae , Hemossiderose/veterinária , Ferro/metabolismo , Fígado/patologia , Animais , Biópsia/veterinária , Doenças das Aves/diagnóstico por imagem , Doenças das Aves/patologia , Cromatografia em Camada Fina/métodos , Cromatografia em Camada Fina/normas , Cromatografia em Camada Fina/veterinária , Hemossiderose/diagnóstico , Hemossiderose/diagnóstico por imagem , Hemossiderose/patologia , Ferro/análise , Complexo Ferro-Dextran/toxicidade , Fígado/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Imageamento por Ressonância Magnética/normas , Imageamento por Ressonância Magnética/veterinária , Valor Preditivo dos Testes , Reprodutibilidade dos Testes , Fatores de Tempo , Ultrassonografia
18.
J Am Vet Med Assoc ; 229(11): 1743-8, 2006 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-17144819

RESUMO

OBJECTIVE: To evaluate the effect of oral administration of melatonin on clinical signs, tumor size, and serum steroid hormone concentrations in ferrets with adrenocortical disease. DESIGN: Noncontrolled clinical trial. ANIMALS: 10 adult ferrets with clinical signs of adrenocortical disease (confirmed via serum steroid hormone concentration assessments). PROCEDURES: Melatonin (0.5 mg) was administered orally to ferrets once daily for 1 year. At 4-month intervals, a complete physical examination; abdominal ultrasonographic examination (including adrenal gland measurement); CBC; serum biochemical analyses; and assessment of serum estradiol, androstenedione, and 17alpha-hydroxyprogesterone concentrations were performed. Serum prolactin and dehydroepiandrosterone sulfate concentrations were evaluated at the first, second, and last examinations, and serum cortisol concentration was evaluated at the first and last examinations. RESULTS: Daily oral administration of melatonin greatly affected clinical signs of adrenocortical disease in ferrets; changes included hair regrowth, decreased pruritus, increased activity level and appetite, and decreased vulva or prostate size. Mean width of the abnormally large adrenal glands was significantly increased after the 12-month treatment period. Recurrence of clinical signs was detected in 6 ferrets at the 8-month evaluation. Compared with pretreatment values, serum 17alpha-hydroxyprogesterone and prolactin concentrations were significantly increased and decreased after 12 months, respectively. CONCLUSIONS AND CLINICAL RELEVANCE: Results suggest that melatonin is a useful, easily administered, palliative treatment to decrease clinical signs associated with adrenocortical disease in ferrets, and positive effects of daily treatment were evident for at least an 8-month period. Oral administration of melatonin did not decrease adrenal gland tumor growth in treated ferrets.


Assuntos
Doenças do Córtex Suprarrenal/veterinária , Neoplasias do Córtex Suprarrenal/veterinária , Furões , Melatonina/uso terapêutico , Administração Oral , Doenças do Córtex Suprarrenal/sangue , Doenças do Córtex Suprarrenal/tratamento farmacológico , Doenças do Córtex Suprarrenal/patologia , Neoplasias do Córtex Suprarrenal/sangue , Neoplasias do Córtex Suprarrenal/tratamento farmacológico , Neoplasias do Córtex Suprarrenal/patologia , Animais , Feminino , Furões/sangue , Hormônios Esteroides Gonadais/sangue , Masculino , Tamanho do Órgão , Cuidados Paliativos , Fatores de Tempo
20.
Am J Vet Res ; 77(11): 1276-1287, 2016 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-27805443

RESUMO

OBJECTIVE To evaluate use of single manual alveolar recruitment maneuvers (ARMs) to eliminate atelectasis during CT of anesthetized foals. ANIMALS 6 neonatal Standardbred foals. PROCEDURES Thoracic CT was performed on spontaneously breathing anesthetized foals positioned in sternal (n = 3) or dorsal (3) recumbency when foals were 24 to 36 hours old (time 1), 4 days old (time 2), 7 days old (time 3), and 10 days old (time 4). The CT images were collected without ARMs (all times) and during ARMs with an internal airway pressure of 10, 20, and 30 cm H2O (times 2 and 3). Quantitative analysis of CT images measured whole lung and regional changes in attenuation or volume with ARMs. RESULTS Increased attenuation and an alveolar pattern were most prominent in the dependent portion of the lungs. Subjectively, ARMs did not eliminate atelectasis; however, they did incrementally reduce attenuation, particularly in the nondependent portion of the lungs. Quantitative differences in lung attenuation attributable to position of foal were not identified. Lung attenuation decreased significantly (times 2 and 3) and lung volume increased significantly (times 2 and 3) after ARMs. Changes in attenuation and volume were most pronounced in the nondependent portion of the lungs and at ARMs of 20 and 30 cm H2O. CONCLUSIONS AND CLINICAL RELEVANCE Manual ARMs did not eliminate atelectasis but reduced attenuation in nondependent portions of the lungs. Positioning of foals in dorsal recumbency for CT may be appropriate when pathological changes in the ventral portion of the lungs are suspected.


Assuntos
Artefatos , Doenças dos Cavalos/diagnóstico por imagem , Alvéolos Pulmonares , Atelectasia Pulmonar/veterinária , Tomografia Computadorizada por Raios X/veterinária , Animais , Animais Recém-Nascidos , Feminino , Cavalos , Pulmão/diagnóstico por imagem , Medidas de Volume Pulmonar , Masculino , Atelectasia Pulmonar/diagnóstico por imagem , Volume de Ventilação Pulmonar
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa