Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 77
Filtrar
1.
Cell ; 164(5): 859-71, 2016 Feb 25.
Artigo em Inglês | MEDLINE | ID: mdl-26898329

RESUMO

Identifying interventions that more effectively promote healthy growth of children with undernutrition is a pressing global health goal. Analysis of human milk oligosaccharides (HMOs) from 6-month-postpartum mothers in two Malawian birth cohorts revealed that sialylated HMOs are significantly less abundant in those with severely stunted infants. To explore this association, we colonized young germ-free mice with a consortium of bacterial strains cultured from the fecal microbiota of a 6-month-old stunted Malawian infant and fed recipient animals a prototypic Malawian diet with or without purified sialylated bovine milk oligosaccharides (S-BMO). S-BMO produced a microbiota-dependent augmentation of lean body mass gain, changed bone morphology, and altered liver, muscle, and brain metabolism in ways indicative of a greater ability to utilize nutrients for anabolism. These effects were also documented in gnotobiotic piglets using the same consortium and Malawian diet. These preclinical models indicate a causal, microbiota-dependent relationship between S-BMO and growth promotion.


Assuntos
Desenvolvimento Infantil , Desnutrição/dietoterapia , Leite Humano/química , Leite/química , Oligossacarídeos/metabolismo , Animais , Bacteroides fragilis/genética , Bifidobacterium/classificação , Bifidobacterium/genética , Química Encefálica , Modelos Animais de Doenças , Escherichia coli/genética , Fezes/microbiologia , Vida Livre de Germes , Humanos , Lactente , Malaui , Masculino , Metabolômica , Camundongos , Camundongos Endogâmicos C57BL , Microbiota
2.
N Engl J Med ; 387(14): 1292-1302, 2022 10 06.
Artigo em Inglês | MEDLINE | ID: mdl-36036522

RESUMO

BACKGROUND: The extravascular implantable cardioverter-defibrillator (ICD) has a single lead implanted substernally to enable pause-prevention pacing, antitachycardia pacing, and defibrillation energy similar to that of transvenous ICDs. The safety and efficacy of extravascular ICDs are not yet known. METHODS: We conducted a prospective, single-group, nonrandomized, premarket global clinical study involving patients with a class I or IIa indication for an ICD, all of whom received an extravascular ICD system. The primary efficacy end point was successful defibrillation at implantation. The efficacy objective would be met if the lower boundary of the one-sided 97.5% confidence interval for the percentage of patients with successful defibrillation was greater than 88%. The primary safety end point was freedom from major system- or procedure-related complications at 6 months. The safety objective would be met if the lower boundary of the one-sided 97.5% confidence interval for the percentage of patients free from such complications was greater than 79%. RESULTS: A total of 356 patients were enrolled, 316 of whom had an implantation attempt. Among the 302 patients in whom ventricular arrhythmia could be induced and who completed the defibrillation testing protocol, the percentage of patients with successful defibrillation was 98.7% (lower boundary of the one-sided 97.5% confidence interval [CI], 96.6%; P<0.001 for the comparison with the performance goal of 88%); 299 of 316 patients (94.6%) were discharged with a working ICD system. The Kaplan-Meier estimate of the percentage of patients free from major system- or procedure-related complications at 6 months was 92.6% (lower boundary of the one-sided 97.5% CI, 89.0%; P<0.001 for the comparison with the performance goal of 79%). No major intraprocedural complications were reported. At 6 months, 25 major complications were observed, in 23 of 316 patients (7.3%). The success rate of antitachycardia pacing, as assessed with generalized estimating equations, was 50.8% (95% CI, 23.3 to 77.8). A total of 29 patients received 118 inappropriate shocks for 81 arrhythmic episodes. Eight systems were explanted without extravascular ICD replacement over the 10.6-month mean follow-up period. CONCLUSIONS: In this prospective global study, we found that extravascular ICDs were implanted safely and were able to detect and terminate induced ventricular arrhythmias at the time of implantation. (Funded by Medtronic; ClinicalTrials.gov number, NCT04060680.).


Assuntos
Desfibriladores Implantáveis , Arritmias Cardíacas/terapia , Desfibriladores Implantáveis/efeitos adversos , Cardioversão Elétrica/efeitos adversos , Humanos , Estudos Prospectivos , Resultado do Tratamento
3.
Proc Natl Acad Sci U S A ; 118(21)2021 05 25.
Artigo em Inglês | MEDLINE | ID: mdl-34001614

RESUMO

The concept that gut microbiome-expressed functions regulate ponderal growth has important implications for infant and child health, as well as animal health. Using an intergenerational pig model of diet restriction (DR) that produces reduced weight gain, we developed a feature-selection algorithm to identify representative characteristics distinguishing DR fecal microbiomes from those of full-fed (FF) pigs as both groups consumed a common sequence of diets during their growth cycle. Gnotobiotic mice were then colonized with DR and FF microbiomes and subjected to controlled feeding with a pig diet. DR microbiomes have reduced representation of genes that degrade dominant components of late growth-phase diets, exhibit reduced production of butyrate, a key host-accessible energy source, and are causally linked to reduced hepatic fatty acid metabolism (ß-oxidation) and the selection of alternative energy substrates. The approach described could aid in the development of guidelines for microbiome stewardship in diverse species, including farm animals, in order to support their healthy growth.


Assuntos
Butiratos/metabolismo , Microbioma Gastrointestinal/fisiologia , Metabolismo dos Lipídeos/fisiologia , Desnutrição/metabolismo , Monoéster Fosfórico Hidrolases/metabolismo , alfa-Glucosidases/metabolismo , Algoritmos , Animais , Peso Corporal , Dieta/métodos , Dietoterapia/métodos , Modelos Animais de Doenças , Fezes/microbiologia , Vida Livre de Germes , Fígado/metabolismo , Masculino , Desnutrição/fisiopatologia , Camundongos , Camundongos Endogâmicos C57BL , Amido/metabolismo , Sacarose/metabolismo , Suínos , Ácido Taurocólico/metabolismo
4.
Heart Lung Circ ; 32(3): 373-378, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-36550006

RESUMO

BACKGROUND: Left ventricular (LV) dysfunction is known to occur after right ventricular (RV) pacing; the effect on RV function is less well studied. The aim of this study was to assess the impact of RV mid-septal pacing upon RV function using the novel parameters of speckle-tracking derived RV global longitudinal strain (RV GLS) and RV free wall strain (RV FWS), as well as the conventional parameters RV fractional area change (FAC), tricuspid annular plane systolic excursion (TAPSE), and tricuspid annular systolic velocity (RV S'). METHODS: Thirty-two (32) consecutive patients with normal baseline LV and RV function requiring permanent pacemaker insertion (for high-grade AV block or sinus node dysfunction) were prospectively recruited. Echocardiography was performed prior to implantation, at 1 day, 1 month and 1 year after implantation, with 29 patients completing follow-up. RESULTS: After 1 year, three patients (10%) with otherwise normal RV parameters developed abnormal RV strain patterns. Compared to 1 day after implantation, at 1 year significant reductions were observed in mean RV GLS (-24.8 to -21.8%) RV S' (15.1 to 12.2 cm/s), TAPSE (24.2 to 21.9 mm), RV GLS (-24.8 to -21.8%), left ventricular ejection fraction (LVEF) (66.0 to 57.9%), LV GLS (-19.9 to 17.0), all p<0.01. There was a non-significant reduction for RV FWS (-29.0 to -26.7%, p=0.06) and there was no change in RV FAC (49.1 to 46.9%, p=0.24). CONCLUSION: We report abnormalities of RV strain developing 1 year after pacemaker insertion. Measurement of myocardial strain is emerging as an additional method to detect patients at risk of RV dysfunction in those who have undergone pacemaker implantation.


Assuntos
Disfunção Ventricular Direita , Função Ventricular Esquerda , Humanos , Estudos Prospectivos , Volume Sistólico , Ecocardiografia/métodos , Ventrículos do Coração/diagnóstico por imagem , Função Ventricular Direita , Disfunção Ventricular Direita/diagnóstico por imagem , Disfunção Ventricular Direita/etiologia
5.
J Cardiovasc Electrophysiol ; 33(6): 1085-1095, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-35478368

RESUMO

INTRODUCTION: The extravascular implantable cardioverter-defibrillato (EV ICD) system with substernal lead placement is a novel nontransvenous alternative to current commercially available ICD systems. The EV ICD provides defibrillation and pacing therapies without the potential long-term complications of endovascular lead placement but requires a new procedure for implantation with a safety profile under evaluation. METHODS: This paper summarizes the development of the EV ICD, including the preclinical and clinical evaluations that have contributed to the system and procedural refinements to date. RESULTS: Extensive preclinical research evaluations and four human clinical studies with >140 combined acute and chronic implants have enabled the development and refinement of the EV ICD system, currently in worldwide pivotal study. CONCLUSION: The EV ICD may represent a clinically valuable solution in protecting patients from sudden cardiac death while avoiding the long-term consequences of transvenous hardware. The EV ICD offers advantages over transvenous and subcutaneous systems by avoiding placement in the heart and vasculature; relative to subcutaneous systems, EV ICD requires less energy for defibrillation, enabling a smaller device, and provides pacing features such as antitachycardia and asystole pacing in a single system.


Assuntos
Desfibriladores Implantáveis , Parada Cardíaca , Morte Súbita Cardíaca/etiologia , Morte Súbita Cardíaca/prevenção & controle , Parada Cardíaca/diagnóstico , Parada Cardíaca/etiologia , Parada Cardíaca/terapia , Humanos
6.
Europace ; 24(5): 762-773, 2022 05 03.
Artigo em Inglês | MEDLINE | ID: mdl-34662385

RESUMO

AIMS: The aim of this study is to provide a thorough, quantified assessment of the substernal space as the site of extravascular implantable cardioverter-defibrillator (ICD) lead placement using computed tomography (CT) scans and summarizing adverse events and defibrillation efficacy across anatomical findings. Subcutaneous ICDs are an alternative to transvenous defibrillators but have limitations related to ICD lead distance from the heart. An alternative extravascular system with substernal lead placement has the potential to provide defibrillation at lower energy and pacing therapies from a single device. METHODS AND RESULTS: A multi-centre, non-randomized, retrospective analysis of 45 patient CT scans quantitatively and qualitatively assessing bony, cardiac, vascular, and other organ structures from two human clinical studies with substernal lead placement. Univariate logistic regression was used to evaluate 15 anatomical parameters for impact on defibrillation outcome and adjusted for multiple comparisons. Adverse events were summarized. Substernal implantation was attempted or completed in 45 patients. Defibrillation testing was successful in 37 of 41 subjects (90%) using ≥10 J safety margin. There were two intra-procedural adverse events in one patient, including reaction to anaesthesia and an episode of transient atrial fibrillation during ventricular fibrillation induction. Anatomical factors associated with defibrillation failure included large rib cage width, myocardium extending very posteriorly, and a low heart position in the chest (P-values <0.05), though not significant adjusting for multiple comparisons. CONCLUSION: Retrospective analysis demonstrates the ability to implant within the substernal space with low intra-procedural adverse events and high defibrillation efficacy despite a wide range of anatomical variability.


Assuntos
Desfibriladores Implantáveis , Arritmias Cardíacas/terapia , Desfibriladores Implantáveis/efeitos adversos , Humanos , Estudos Retrospectivos , Fibrilação Ventricular/etiologia , Fibrilação Ventricular/terapia
7.
J Cardiovasc Electrophysiol ; 32(9): 2371-2378, 2021 09.
Artigo em Inglês | MEDLINE | ID: mdl-34322918

RESUMO

BACKGROUND: Transvenous implantable cardioverter defibrillators (TV ICD) provide life-saving therapy for millions of patients worldwide. However, they are susceptible to several potential short- and long- term complications including cardiac perforation and pneumothorax, lead dislodgement, venous obstruction, and infection. The extravascular ICD system's novel design and substernal implant approach avoids the risks associated with TV ICDs while still providing pacing features and similar generator size to TV ICDs. STUDY DESIGN: The EV ICD pivotal study is a prospective, multicenter, single-arm, nonrandomized, premarket clinical study designed to examine the safety and acute efficacy of the system. This study will enroll up to 400 patients with a Class I or IIa indication for implantation of an ICD. Implanted subjects will be followed up to approximately 3.5 years, depending on when the patient is enrolled. OBJECTIVE: The clinical trial is designed to demonstrate safety and effectiveness of the EV ICD system in human use. The safety endpoint is freedom from major complications, while the efficacy endpoint is defibrillation success. Both endpoints will be assessed against prespecified criteria. Additionally, this study will evaluate antitachycardia pacing performance, electrical performance, extracardiac pacing sensation, asystole pacing, appropriate and inappropriate shocks, as well as a summary of adverse events. CONCLUSION: The EV ICD pivotal study is designed to provide clear evidence addressing the safety and efficacy performance of the EV ICD System.


Assuntos
Desfibriladores Implantáveis , Parada Cardíaca , Desfibriladores Implantáveis/efeitos adversos , Humanos , Estudos Prospectivos , Resultado do Tratamento
8.
Pacing Clin Electrophysiol ; 44(10): 1663-1670, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-34319603

RESUMO

BACKGROUND: Cardiac resynchronization therapy (CRT) involves stimulation of both right ventricle (RV) and left ventricle (LV). LV pacing from the sites of delayed electrical activation improves CRT response. The RV-LV conduction is typically measured in intrinsic rhythm. The differences in RV-LV conduction patterns and timing between intrinsic rhythm and during paced RV activation, these differences are not fully understood. METHODS: Enrolled patients were implanted with a de novo CRT device and quadripolar LV lead, with lead implant locations at the implanting physician's discretion. QRS duration and conduction delay between the RV lead and each of the four LV electrodes (D1, M2, M3, and P4) were measured during intrinsic conduction and RV pacing. RESULTS: Conduction measurements were collected from 275 patients across 14 international centers (68 ± 13 years of age, 73% male, 45% ischemic, 158 ± 22 ms QRS duration). Mean RV-LV conduction time was shorter during intrinsic conduction versus RV pacing by 59.6 ms (106.5 ± 36.5 versus 166.1 ± 32.1 ms, p < 0.001). The intra-LV activation delay between the latest and earliest activating LV electrode was also shorter during intrinsic conduction versus RV pacing by 6.6 ms (20.6 ± 13.1 vs. 27.2 ± 21.2 ms, p < 0.001). Intrinsic conduction and RV pacing resulted in a different activation order in 72.7% of patients, and the same LV activation order in 27.3%. CONCLUSIONS: Differences in RV-LV conduction time, intra-LV conduction time, and activation pattern were observed between intrinsic conduction and RV pacing. These findings highlight the importance of evaluating intrinsic versus paced ventricular activation to guide LV pacing site selection in CRT patients.


Assuntos
Terapia de Ressincronização Cardíaca/métodos , Sistema de Condução Cardíaco/fisiopatologia , Ventrículos do Coração/fisiopatologia , Idoso , Dispositivos de Terapia de Ressincronização Cardíaca , Feminino , Humanos , Masculino , Desenho de Prótese
9.
Health Res Policy Syst ; 19(1): 112, 2021 Aug 11.
Artigo em Inglês | MEDLINE | ID: mdl-34380518

RESUMO

BACKGROUND: Health information systems are crucial to provide data for decision-making and demand for data is constantly growing. However, the link between data and decisions is not always rational or linear and the management of data ends up overloading frontline health workers, which may compromise quality of healthcare delivery. Despite limited evidence, there is an increasing push for the digitalization of health information systems, which poses enormous challenges, particularly in remote, rural settings in low- and middle-income countries. Paper-based tools will continue to be used in combination with digital solutions and this calls for efforts to make them more responsive to local needs. Paper-based Health Information Systems in Comprehensive Care (PHISICC) is a transdisciplinary, multi-country research initiative to create and test innovative paper-based health information systems in three sub-Saharan African countries. METHODS/DESIGN: The PHISICC initiative is being carried out in remote, rural settings in Côte d'Ivoire, Mozambique and Nigeria through partnership with ministries of health and research institutions. We began with research syntheses to acquire the most up-to-date knowledge on health information systems. These were coupled with fieldwork in the three countries to understand the current design, patterns and contexts of use, and healthcare worker perspectives. Frontline health workers, with designers and researchers, used co-creation methods to produce the new PHISICC tools. This suite of tools is being tested in the three countries in three cluster-randomized controlled trials. Throughout the project, we have engaged with a wide range of stakeholders and have maintained the highest scientific standards to ensure that results are relevant to the realities in the three countries. DISCUSSION: We have deployed a comprehensive research approach to ensure the robustness and future policy uptake of findings. Besides the innovative PHISICC paper-based tools, our process is in itself innovative. Rather than emphasizing the technical dimensions of data management, we focused instead on frontline health workers' data use and decision-making. By tackling the whole scope of primary healthcare areas rather than a subset of them, we have developed an entirely new design and visual language for a suite of tools across healthcare areas. The initiative is being tested in remote, rural areas where the most vulnerable live.


Assuntos
Sistemas de Informação em Saúde , Gerenciamento de Dados , Atenção à Saúde , Pessoal de Saúde , Humanos , Moçambique
10.
J Cardiovasc Electrophysiol ; 31(4): 825-833, 2020 04.
Artigo em Inglês | MEDLINE | ID: mdl-32009263

RESUMO

BACKGROUND: The AdaptivCRT (aCRT) algorithm continuously adjusts cardiac resynchronization therapy (CRT) according to intrinsic atrioventricular conduction, providing synchronized left ventricular pacing in patients with normal PR interval and adaptive BiV pacing in patients with prolonged PR interval. Previous analyses demonstrated an association between aCRT and clinical benefit. We evaluated the incidence of patient mortality and atrial fibrillation (AF) with aCRT compared with standard CRT in a real-world population. METHODS AND RESULTS: Patients enrolled in the Medtronic Personalized CRT Registry and implanted with a CRT from 2013-2018 were divided into aCRT ON or standard CRT groups based upon device-stored data. A Frailty survival model was used to evaluate the potential survival benefit of aCRT, accounting for patient heterogeneity and center variability. Daily AF burden and first device-detected AF episodes of various durations were recorded by the device during follow-up. A total of 1814 CRT patients with no reported long-standing AF history at implant were included. Mean follow-up time was 26.1 ± 16.5 months and 1162 patients (64.1%) had aCRT ON. Patient survival probability at 36 months was 88.3% for aCRT ON and 83.7% for standard CRT (covariate-adjusted hazard ratio [HR] = 0.71, 95% CI: 0.53-0.96, P = .028). Mean AF burden during follow-up was consistently lower in aCRT ON patients compared with standard CRT. At 36 months, the probability of AF was lower in patients with aCRT ON, regardless of which AF definition threshold was applied (6 minutes-30 days, all P < .001). CONCLUSION: Use of the AdaptivCRT algorithm was associated with improved patient survival and lower incidence of AF in a real-world, prospective, nonrandomized registry.


Assuntos
Algoritmos , Fibrilação Atrial/epidemiologia , Dispositivos de Terapia de Ressincronização Cardíaca , Terapia de Ressincronização Cardíaca/efeitos adversos , Insuficiência Cardíaca/terapia , Terapia Assistida por Computador/instrumentação , Idoso , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/mortalidade , Terapia de Ressincronização Cardíaca/mortalidade , Feminino , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/mortalidade , Insuficiência Cardíaca/fisiopatologia , Humanos , Incidência , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Sistema de Registros , Medição de Risco , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
11.
J Cardiovasc Electrophysiol ; 30(8): 1306-1312, 2019 08.
Artigo em Inglês | MEDLINE | ID: mdl-31045305

RESUMO

BACKGROUND: Postoperative heart block is common among patients undergoing surgery for infective endocarditis (IE). Limited data exists allowing cardiologists to predict who will require permanent pacemaker (PPM) implantation postoperatively. We aimed to determine the rate of postoperative PPM insertion, predictors for postoperative PPM, and describe PPM utilization and rates of device-related infection during follow-up. MATERIALS AND METHODS: A retrospective analysis was performed of 191 consecutive patients from a single institution who underwent cardiac surgery for IE between 2001 and 2017. Preoperative and operative predictors for postoperative PPM were evaluated using univariate and multivariate logistic regression. RESULTS: The rate of postoperative PPM implantation was 11% (17/154). The PPM group had more preoperative prolonged PR interval alone (33% vs 12%; P = .03), coexistent prolonged PR and QRS durations (13% vs 2%; P = .01), infection beyond the valve leaflets (82% vs 41%; P = .001), aortic root debridement (65% vs 23%; P = <.001), patch repair (47% vs 20%; P = .01), postoperative prolonged PR interval (50% vs 24%; P = .01), and prolonged QRS duration (47% vs 15%; P = .001). On multivariate analysis, infection beyond the valve leaflets emerged as an independent predictor for postoperative PPM (odds ratio, 1.94, 95% confidence interval, 1.14-3.28; P = .014). A reduction in PPM utilization was observed in five patients while eight patients continued to show significant ventricular pacing with no underlying rhythm at 12 months. There were no device-related infections. CONCLUSION: Postoperative PPM was required in 11% of patients undergoing surgery for IE over a 16-year period. Infection beyond the valve leaflet was an independent predictor for postoperative PPM insertion.


Assuntos
Estimulação Cardíaca Artificial , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Endocardite/cirurgia , Bloqueio Cardíaco/terapia , Frequência Cardíaca , Marca-Passo Artificial , Potenciais de Ação , Adulto , Idoso , Estimulação Cardíaca Artificial/efeitos adversos , Feminino , Bloqueio Cardíaco/diagnóstico , Bloqueio Cardíaco/etiologia , Bloqueio Cardíaco/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Marca-Passo Artificial/efeitos adversos , Infecções Relacionadas à Prótese/etiologia , Recuperação de Função Fisiológica , Sistema de Registros , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Centros de Atenção Terciária , Fatores de Tempo , Resultado do Tratamento , Vitória
12.
Europace ; 21(1): 80-90, 2019 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-29912306

RESUMO

AIMS: Atrio-oesophageal fistula (AOF) is a potentially lethal complication of atrial fibrillation (AF) ablation. Many studies have evaluated the presence and prevention of endoscopically-detected oesophageal lesions (EDOL) as a proxy measure for risk of AOF. This systematic review and meta-analysis sought to determine the prevalence of EDOL and effectiveness of general preventive measures during AF ablation. METHODS AND RESULTS: We searched electronic databases for studies reporting prevalence or prevention of EDOL post-AF ablation. Pooled prevalence were reported with 95% confidence intervals (CI) while studies evaluating preventive measures including oesophageal temperature monitoring (OTM), esophageal manipulation and type of anaesthesia were analyzed descriptively or by random-effects modeling. Twenty-five studies were included in the analysis. Any and ulcerated EDOL pooled prevalence was 11% (95%CI, 6-15%) and 5% (95%CI, 3-7%), respectively. In six studies, there was no difference in EDOL with or without OTM (pooled OR 1.65, 95%CI, 0.22-12.55). There was no difference using a multi-sensor versus single-sensor OTM (one study) nor when using a deflectable probe (two studies). Oesophageal displacement was associated with significant instrumentation injury in one study. Two studies evaluating Oesophageal cooling showed conflicting results. General anaesthesia was associated with more EDOL than conscious sedation in two studies. CONCLUSION: The pooled prevalence of any and ulcerated EDOL post-ablation was 11% and 5%, but varied between studies. Techniques such as OTM and oesophageal displacement or cooling have not conclusively demonstrated a reduction in EDEL, while general anaesthesia may be associated with higher EDOL risk. Further randomized data are critically needed to validate and develop measures to prevent EDOL and AOF.


Assuntos
Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Fístula Esofágica/epidemiologia , Fístula Esofágica/prevenção & controle , Esôfago/lesões , Átrios do Coração/lesões , Traumatismos Cardíacos/epidemiologia , Traumatismos Cardíacos/prevenção & controle , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/epidemiologia , Fístula Esofágica/diagnóstico , Esofagoscopia , Traumatismos Cardíacos/diagnóstico , Humanos , Prevalência , Fatores de Risco , Resultado do Tratamento
13.
J Cardiovasc Electrophysiol ; 29(6): 861-871, 2018 06.
Artigo em Inglês | MEDLINE | ID: mdl-29603477

RESUMO

INTRODUCTION: Atrioesophageal fistula (AEF) is a dire complication of atrial fibrillation ablation. The diagnostic yield of computed tomography (CT) chest, the role and timing of repeat testing, and the value of other investigations in the diagnosis of AEF is uncertain. METHODS: We systematically reviewed published AEF cases to evaluate radiological, bedside, and biochemical investigations for AEF (registered on PROSPERO [CRD42017077493]). RESULTS: Eighty-seven articles with 126 patients (median age, 59 years; male, 71%) were included in the analysis. CT chest was performed in 88% (111/126) and was abnormal in 87%. A clear diagnosis of AEF (fistula/perforation) was only detected in 35% (34/97). Other major findings included free air in mediastinum (26%), left atrium (LA), or LA wall (24%). In 11 patients with normal/nonspecific initial CT chest, major abnormalities were detected in 91% (10/11) of repeat CT chest performed 6 days (median; range, 4-22) after initial scan. Initial CT head was normal in 51%; diffuse air emboli was identified in 79% (22/28). Initial transthoracic echocardiography was normal in 61% of cases. The spectrum of radiological abnormalities included Air (mediastinum/LA), Effusion (pleural/pericardial), Fistula/Perforation, and Thickening (esophagus/LA) - "AEF-Tests." Esophagram demonstrated contrast extravasation in 87% (13/15). Blood culture was consistently positive (100%; 28/28), particularly for streptococcus species (93%; 26/28). CONCLUSION: The diagnosis of AEF remains challenging. Clinicians should be aware of the limitations in the yield of CT chest, the variety of major abnormalities reported, the need for repeat testing, unique brain imaging findings, and the importance of positive blood cultures and raised inflammatory markers.


Assuntos
Fibrilação Atrial/complicações , Fístula Esofágica/diagnóstico por imagem , Fístula/diagnóstico por imagem , Átrios do Coração/diagnóstico por imagem , Cardiopatias/diagnóstico por imagem , Tomografia Computadorizada por Raios X , Adulto , Idoso , Idoso de 80 Anos ou mais , Fibrilação Atrial/diagnóstico , Biomarcadores/sangue , Diagnóstico Diferencial , Ecocardiografia , Fístula Esofágica/sangue , Fístula Esofágica/etiologia , Feminino , Fístula/sangue , Fístula/etiologia , Cardiopatias/sangue , Cardiopatias/etiologia , Humanos , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Testes Imediatos , Valor Preditivo dos Testes , Prognóstico , Reprodutibilidade dos Testes , Fatores de Risco
15.
Europace ; 19(4): 588-595, 2017 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-28431058

RESUMO

AIMS: The aim of this study was to evaluate any benefits to the number of viable pacing vectors and maximal spatial coverage with quadripolar left ventricular (LV) leads when compared with tripolar and bipolar equivalents in patients receiving cardiac resynchronization therapy (CRT). METHODS AND RESULTS: A meta-analysis of five previously published clinical trials involving the Quartet™ LV lead (St Jude Medical, St Paul, MN, USA) was performed to evaluate the number of viable pacing vectors defined as capture thresholds ≤2.5 V and no phrenic nerve stimulation and maximal spatial coverage of viable vectors in CRT patients at pre-discharge (n = 370) and first follow-up (n = 355). Bipolar and tripolar lead configurations were modelled by systematic elimination of two and one electrode(s), respectively, from the Quartet lead. The Quartet lead with its four pacing electrodes exhibited the greatest number of pacing vectors per patient when compared with the best bipolar and the best tripolar modelled equivalents. Similarly, the Quartet lead provided the highest spatial coverage in terms of the distance between two furthest viable pacing cathodes when compared with the best bipolar and the best tripolar configurations (P < 0.05). Among the three modelled bipolar configurations, the lead configuration with the two most distal electrodes resulted in the highest number of viable pacing vectors. Among the four modelled tripolar configurations, elimination of the second proximal electrode (M3) resulted in the highest number of viable pacing options per patient. There were no significant differences observed between pre-discharge and first follow-up analyses. CONCLUSION: The Quartet lead with its four electrodes and the capability to pace from four anatomical locations provided the highest number of viable pacing vectors at pre-discharge and first follow-up visits, providing more flexibility in device programming and enabling continuation of CRT in more patients when compared with bipolar and tripolar equivalents.


Assuntos
Desfibriladores Implantáveis/estatística & dados numéricos , Eletrodos Implantados/estatística & dados numéricos , Insuficiência Cardíaca/epidemiologia , Insuficiência Cardíaca/prevenção & controle , Marca-Passo Artificial/estatística & dados numéricos , Terapia Assistida por Computador/instrumentação , Terapia Assistida por Computador/estatística & dados numéricos , Idoso , Desenho de Equipamento , Análise de Falha de Equipamento , Feminino , Ventrículos do Coração , Humanos , Masculino , Prevalência , Resultado do Tratamento
16.
Heart Lung Circ ; 26(8): e48-e49, 2017 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-28242289

RESUMO

Implantable cardioverter-defibrillator (ICD) and cardiac resynchronisation therapy (CRT) is generally limited to transvenous techniques especially in pacing-dependant patients. We describe a novel case in which an epicardial CRT-D system was successfully implanted with a two-year follow-up in a pacing-dependant patient.


Assuntos
Terapia de Ressincronização Cardíaca , Desfibriladores Implantáveis , Pericárdio , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Pericárdio/diagnóstico por imagem , Pericárdio/fisiopatologia
17.
Heart Lung Circ ; 25(8): 814-9, 2016 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-27320854

RESUMO

Cardiac implantable electronic devices (pacemakers and defibrillators) are increasingly common in modern cardiology practice, and health professionals from a variety of specialties will encounter patients with such devices on a frequent basis. This article will focus on the subset of patients who may request, or be appropriate for, device deactivation and discuss the issues surrounding end-of-life decisions, along with the ethical and legal implications of device deactivation.


Assuntos
Dispositivos de Terapia de Ressincronização Cardíaca , Desfibriladores Implantáveis , Assistência Terminal/métodos , Austrália , Humanos , Assistência Terminal/legislação & jurisprudência
19.
Appl Opt ; 52(8): 1693-701, 2013 Mar 10.
Artigo em Inglês | MEDLINE | ID: mdl-23478774

RESUMO

It has been a long-standing goal to precisely measure water-leaving radiance (L(w), or its equivalent property, remote-sensing reflectance) in the field, but reaching this goal is quite a challenge. This is because conventional approaches do not provide a direct measurement of L(w), but rather measure various related components and subsequently derive this core property from these components. Due to many uncontrollable factors in the measurement procedure and imprecise post-measurement processing routines, the resulting L(w) is inherently associated with various levels of uncertainties. Here we present a methodology called the skylight-blocked approach (SBA) to measure L(w) directly in the field, along with results obtained recently in the Laurentian Great Lakes. These results indicate that SBA can measure L(w) in high precision. In particular, there is no limitation of water types for the deployment of SBA, and the requirement of post-measurement processing is minimum; thus high-quality L(w) for a wide range of aquatic environments can be acquired.

20.
Science ; 379(6628): eadd1236, 2023 01 13.
Artigo em Inglês | MEDLINE | ID: mdl-36634180

RESUMO

Tau-mediated neurodegeneration is a hallmark of Alzheimer's disease. Primary tauopathies are characterized by pathological tau accumulation and neuronal and synaptic loss. Apolipoprotein E (ApoE)-mediated neuroinflammation is involved in the progression of tau-mediated neurodegeneration, and emerging evidence suggests that the gut microbiota regulates neuroinflammation in an APOE genotype-dependent manner. However, evidence of a causal link between the microbiota and tau-mediated neurodegeneration is lacking. In this study, we characterized a genetically engineered mouse model of tauopathy expressing human ApoE isoforms reared under germ-free conditions or after perturbation of their gut microbiota with antibiotics. Both of these manipulations reduced gliosis, tau pathology, and neurodegeneration in a sex- and ApoE isoform-dependent manner. The findings reveal mechanistic and translationally relevant interrelationships between the microbiota, neuroinflammation, and tau-mediated neurodegeneration.


Assuntos
Apolipoproteínas E , Microbioma Gastrointestinal , Doenças Neuroinflamatórias , Tauopatias , Animais , Humanos , Camundongos , Antibacterianos/farmacologia , Apolipoproteínas E/genética , Apolipoproteínas E/metabolismo , Modelos Animais de Doenças , Microbioma Gastrointestinal/efeitos dos fármacos , Microbioma Gastrointestinal/fisiologia , Camundongos Transgênicos , Doenças Neuroinflamatórias/genética , Doenças Neuroinflamatórias/metabolismo , Doenças Neuroinflamatórias/microbiologia , Proteínas tau/genética , Proteínas tau/metabolismo , Tauopatias/genética , Tauopatias/metabolismo , Tauopatias/microbiologia , Fatores Sexuais
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa