Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 12 de 12
Filtrar
1.
Catheter Cardiovasc Interv ; 96(4): 940-946, 2020 10 01.
Artigo em Inglês | MEDLINE | ID: mdl-31797524

RESUMO

OBJECTIVES: We aimed to evaluate early clinical and procedural outcomes with the 34-mm Evolut R transcatheter aortic valve replacement (TAVR) prosthesis. BACKGROUND: The 34-mm Evolut R (Medtronic, Minneapolis, MN) self-expanding TAVR prosthesis was designed to treat patients with larger annuli. METHODS: Clinical, demographic, procedural, and echocardiographic data on consecutive patients who underwent TAVR with a 34-mm Evolut R prosthesis at our institution were collected and analyzed. RESULTS: One hundred ninety-six patients underwent TAVR with this prosthesis from November 2016 to July 2018, a majority (n = 188, 96%) through transfemoral access and with conscious sedation (n = 182, 93%). Mean age, Society of Thoracic Surgery risk score, and follow-up were 82 ± 8 years, 5.4 ± 5%, and 8.2 ± 5.3 months, respectively. Mean aortic valve (AV) peak velocity was 4.0 ± 0.6 m/s, mean AV gradient was 38 ± 13 mmHg, AV area was 0.79 ± 0.23 cm2 ; calcium score was 3,503 ± 1,970 Agatston units, and perimeter was 85 ± 4.3 mm. Device implantation was successful in all but one patient. Postprocedure mean AV peak velocity, AV mean gradient, and AV area were 1.9 ± 0.4 m/s, 7 ± 3 mmHg, and 2.6 ± 0.7 cm2 , respectively. New pacemaker requirement rate was 16%, and moderate paravalvular leak was present in six patients (3%), which improved to mild in three patients at 6-month follow-up. In-hospital, 30-day, 6-month, and 12-month survival rates were 98%, 96% (hospital discharge), 96% (30-day), 89% (6-month), and 83% (12-month). CONCLUSION: These data demonstrate high success and good procedural, echocardiographic, and clinical outcomes of 34-mm Evolut R in patients with large annuli.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter/instrumentação , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/mortalidade , Estenose da Valva Aórtica/fisiopatologia , Feminino , Mortalidade Hospitalar , Humanos , Masculino , Complicações Pós-Operatórias/mortalidade , Complicações Pós-Operatórias/terapia , Desenho de Prótese , Recuperação de Função Fisiológica , Estudos Retrospectivos , Fatores de Risco , Índice de Gravidade de Doença , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/mortalidade , Resultado do Tratamento
2.
Catheter Cardiovasc Interv ; 93(4): 740-748, 2019 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-30341970

RESUMO

OBJECTIVES: To assess the treatment effect of TAVR versus SAVR on clinical outcomes to 3 years in patients stratified by chronic kidney disease (CKD) by retrospectively studying patients randomized to TAVR or SAVR. BACKGROUND: The impact of CKD on mid-term outcomes of patients undergoing TAVR versus SAVR is unclear. METHODS: Patients randomized to TAVR or SAVR in the CoreValve US Pivotal High Risk Trial were retrospectively stratified by eGFR: none/mild or moderate/severe CKD. To evaluate the impact of baseline CKD in TAVR patients only, all patients undergoing an attempted TAVR implant in the US Pivotal Trial and CAS were stratified by baseline eGFR into none/mild, moderate, and severe CKD. The primary endpoint was major adverse cardiovascular and renal events (MACRE), a composite of all-cause mortality, myocardial infarction, stroke/TIA, and new requirement of dialysis. RESULTS: Moderate/severe CKD was present in 62.7% and 60.7% of high-risk patients randomized to TAVR or SAVR, respectively. Baseline characteristics were similar between TAVR and SAVR patients in both CKD subgroups, except for higher rates of diabetes and higher serum creatinine in SAVR patients. Among high-risk patients with moderate/severe CKD, TAVR provided a lower 3-year MACRE rate compared with SAVR: 42.1% vs. 51.0, P = .04. Of 3,733 extreme- and high-risk TAVR patients, 39.9% had none/mild, 53.8% moderate, and 6.4% severe CKD. Worsening baseline CKD was associated with increased 3-year MACRE rates [none/mild 51.5%, moderate 54.5%, severe 63.1%, P = .001]. CONCLUSIONS: TAVR results in lower 3-year MACRE versus SAVR in high-risk patients with moderate/severe CKD. In patients undergoing TAVR, worsening CKD increases mid-term mortality and MACRE. Randomized trials of TAVR vs. SAVR in patients with moderate-severe CKD would help elucidate the best treatment for these complex patients. TRIAL REGISTRATION: CoreValve US Pivotal Trial: NCT01240902. CoreValve Continued Access Study: NCT01531374.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Taxa de Filtração Glomerular , Implante de Prótese de Valva Cardíaca , Rim/fisiopatologia , Insuficiência Renal Crônica/fisiopatologia , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/mortalidade , Estenose da Valva Aórtica/fisiopatologia , Feminino , Próteses Valvulares Cardíacas , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/instrumentação , Implante de Prótese de Valva Cardíaca/mortalidade , Humanos , Masculino , Ensaios Clínicos Controlados Aleatórios como Assunto , Diálise Renal , Insuficiência Renal Crônica/diagnóstico , Insuficiência Renal Crônica/mortalidade , Insuficiência Renal Crônica/terapia , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/instrumentação , Substituição da Valva Aórtica Transcateter/mortalidade , Resultado do Tratamento , Estados Unidos
3.
Struct Heart ; 8(3): 100278, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38799807

RESUMO

Background: The current clinical practice standard is 10% to 20% oversizing of self-expanding valves in transcatheter aortic valve replacement. We aimed to determine whether >20% oversizing of self-expanding valves (Medtronic Evolut) would lead to better valve performance with similar or better outcomes. Methods: From October 2011 to December 2016, we approached all transcatheter aortic valve replacement patients with a conscious attempt at large oversizing (>20%). The most common valve used, excluding those used in valve-in-valve patients, was the 29-mm Evolut R (29%). We used a retrospective chart review to compare moderate oversizing (group 1; 10% to 20%) with large oversizing (group 2; >20%). Results: Of 556 patients, 45% were male; the overall mean Society of Thoracic Surgeons risk score was 5.8 ± 3.8. Eighty-five (15%) patients needed a pacemaker, and 21 (3.8%) developed significant paravalvular leak. Mean oversizing was 20.3% ± 6.0%, with 41.4% of patients included in group 1 and 54.5% in group 2. Incidences of complications in group 2 vs. group 1 were as follows: a) paravalvular leak (2.0 vs. 6.1%; odds ratio = 0.31, p = 0.01), b) pacemaker (15 vs. 14%), c) gastrointestinal bleed (n = 4 vs. 0; 1.3 vs. 0.0%; p = 0.03), d) annular dissection (n = 1 vs. 0; 0.3 vs. 0%; p = 0.29), e) mortality (n = 5 vs. 4; 1.6 vs. 1.7%). Incidence of paravalvular leak was higher in those who died than survivors (13 vs. 1.3%; p ≤ 0.0001). Conclusions: These data suggest that, in current self-expanding valves, >20% oversizing delivers a significantly lower prevalence of paravalvular leak without an increase in other complications. Since paravalvular leak is associated with increased mortality, >20% oversizing may represent a superior prosthesis choice.

4.
Ann Thorac Surg ; 113(5): 1499-1504, 2022 05.
Artigo em Inglês | MEDLINE | ID: mdl-34139187

RESUMO

BACKGROUND: Undertreatment of heart valve disease creates unnecessary patient risk. Poorly integrated healthcare data systems are unequipped to solve this problem. A software program using a rules-based algorithm to search the electronic health record for heart valve disease among patients treated by healthcare systems in the United States may provide a solution. METHODS: A software interface allowed concurrent access to picture archiving communication systems, the electronic health record, and other sources. The software platform was created to programmatically run a rules engine to search structured and unstructured data for identification of moderate or severe heart valve disease using guideline-reported values. Incidence and progression of disease as well as compliance with a care pathway were assessed. RESULTS: In 2 health institutions in the United States 60,145 patients had 77,215 echocardiograms. Moderate or severe aortic stenosis (AS) was identified at a rate of 9.1% of patients (5474 and 6910 echocardiograms) in this population. The precision and accuracy of the algorithm for the detection of moderate or severe AS was 92.9% and 98.6%, respectively. Thirty-five percent of patients (441/1265) with moderate stenosis and a subsequent echocardiogram progressed to severe stenosis (mean interval, 358 days). In 1 sample 70.3% of moderate AS patients lacked a 6-month echocardiogram or appointment. The platform enabled 100% accountability for all patients with severe AS. CONCLUSIONS: A rules-based software program enhances detection of heart valve disease and can be used to measures disease progression and care pathway compliance.


Assuntos
Estenose da Valva Aórtica , Doenças das Valvas Cardíacas , Implante de Prótese de Valva Cardíaca , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Inteligência Artificial , Constrição Patológica , Ecocardiografia , Doenças das Valvas Cardíacas/diagnóstico por imagem , Humanos , Índice de Gravidade de Doença , Resultado do Tratamento , Estados Unidos/epidemiologia
5.
Circ Cardiovasc Interv ; 12(10): e008155, 2019 10.
Artigo em Inglês | MEDLINE | ID: mdl-31607151

RESUMO

BACKGROUND: Valve-in-valve transcatheter aortic valve replacement (TAVR) is an option when a surgical valve demonstrates deterioration and dysfunction. This study reports 3-year results following valve-in-valve with self-expanding TAVR. METHODS: The CoreValve US Expanded Use Study is a prospective, nonrandomized, single-arm study that evaluates safety and effectiveness of TAVR in extreme risk patients with symptomatic failed surgical biologic aortic valves. Study end points include all-cause mortality, need for valve reintervention, hemodynamic changes over time, and quality of life through 3 years. Patients were stratified by presence of preexisting surgical valve prosthesis-patient mismatch. RESULTS: From March 2013 to May 2015, 226 patients deemed extreme risk (STS-PROM [Society of Thoracic Surgeons Predicted Risk of Mortality] 9.0±7%) had attempted valve-in-valve TAVR. Preexisting surgical valve prosthesis-patient mismatch was present in 47.2% of the cohort. At 3 years, all-cause mortality or major stroke was 28.6%, and 93% of patients were in New York Heart Association I or II heart failure. Valve performance was maintained over 3 years with low valve reintervention rates (4.4%), an improvement in effective orifice area over time and a 2.7% rate of severe structural valve deterioration. Preexisting severe prosthesis-patient mismatch was not associated with 3-year mortality but was associated with significantly less improvement in quality of life at 3-year follow-up (P=0.01). CONCLUSIONS: Self-expanding TAVR in patients with failed surgical bioprostheses at extreme risk for surgery was associated with durable hemodynamics and excellent clinical outcomes. Preexisting surgical valve prosthesis-patient mismatch was not associated with mortality but did limit patient improvement in quality of life over 3-year follow-up. CLINICAL TRIAL REGISTRATION: URL: http://www.clinicaltrials.gov. Unique identifier: NCT01675440.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Implante de Prótese de Valva Cardíaca/instrumentação , Próteses Valvulares Cardíacas , Falha de Prótese , Substituição da Valva Aórtica Transcateter/instrumentação , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/mortalidade , Estenose da Valva Aórtica/fisiopatologia , Bioprótese , Feminino , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/mortalidade , Hemodinâmica , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Desenho de Prótese , Qualidade de Vida , Recuperação de Função Fisiológica , Fatores de Risco , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/mortalidade , Resultado do Tratamento
6.
J Mech Behav Biomed Mater ; 86: 131-142, 2018 10.
Artigo em Inglês | MEDLINE | ID: mdl-29986288

RESUMO

CoreValve is widely used in transcatheter aortic valve replacement, but the impact of its deployment location on hemodynamics is unexplored despite a potential role in subsequent aortic and coronary artery pathologies. The objectives of this investigation were to perform fluid-structure interaction (FSI) simulations for a 29 mm CoreValve deployed in annular vs supra-annular locations, and characterize resulting hemodynamics including velocity and wall shear stress (WSS). Patient-specific geometry was reconstructed from computed tomography scans and CoreValve was deployed using a finite element approach. FSI simulations were then performed using a boundary conforming method and realistic boundary conditions. Results showed that CoreValve deployment location impacts hemodynamics in the ascending aorta and flow patterns in the coronary arteries. During peak-systole, annularly deployed CoreValve produced a jet-like flow structure impinging on the outer-curvature of the ascending aorta. Supra-annularly deployed CoreValve having a lateral tilt of 10° led to a more centered jet impinging further downstream. At mid-systole, valve leaflets of the annularly deployed CoreValve closed asymmetrically leading to disorganized flow patterns in the ascending aorta vs those from the supra-annular position. Supra-annularly deployed CoreValve also led to high-velocity para-valvular flow supplying the coronary arteries. CoreValve in the supra-annular position significantly (P < 0.05) elevated WSS within the first few diameters of both coronary arteries as compared to the annular position for many time points quantified. These results afforded by the advanced simulation methods may have important clinical implications given the role of aortic hemodynamics in dilation and the pro-atherogenic nature of WSS alterations in the coronary arteries.


Assuntos
Aorta/fisiologia , Vasos Coronários/fisiologia , Próteses Valvulares Cardíacas , Hemodinâmica , Análise de Elementos Finitos , Humanos , Modelagem Computacional Específica para o Paciente
7.
Ann Thorac Surg ; 105(2): 484-490, 2018 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-29174390

RESUMO

BACKGROUND: Transcatheter aortic valve replacement (TAVR) using a self-expanding valve has been shown to be superior to an open operation in high-risk patients. Extensive iliofemoral peripheral vascular disease can prohibit femoral access. In these cases, direct aortic (DA) implantation may be a suitable option. METHODS: The current analysis compared outcomes in patients undergoing TAVR with the self-expanding CoreValve prosthesis (Medtronic, Minneapolis, MN) by direct aortic (DA) access vs iliofemoral (IF) access. Patients treated in the CoreValve US High Risk and Extreme Risk Pivotal Trials and Continued Access Study were included. Propensity score matching was used to account for differences in baseline characteristics between groups. Clinical outcomes were compared at 30 days and 1 year. RESULTS: We identified 394 matched pairs of IF and DA patients. The all-cause mortality rate was significantly higher in the DA group than in the IF group at 30 days (10.9% vs 4.1%, p < 0.001), but this difference was reduced at 1 year (28.1% vs 23.2%, p = 0.063). All-cause mortality or major stroke was significantly higher for DA vs IF access at 30 days (13.5% vs 5.3%, p < 0.001) and at 1 year (30.4% vs 24.2%, p = 0.025). Major/life-threatening bleeding and acute kidney injury were significantly greater in the DA group at 30 days (66.7% vs 35.4% and 19.7% vs 10.0%, respectively, both p < 0.001). CONCLUSIONS: When femoral access is not feasible, DA access allows effective delivery of the valve but incurs an increased risk of death and adverse events, potentially the result of procedural differences.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Próteses Valvulares Cardíacas , Pontuação de Propensão , Substituição da Valva Aórtica Transcateter/métodos , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/diagnóstico , Ecocardiografia , Feminino , Humanos , Masculino , Desenho de Prótese , Fatores de Tempo , Resultado do Tratamento
9.
Echo Res Pract ; 4(4): 63-72, 2017 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-29101108

RESUMO

BACKGROUND: While transcatheter aortic valve implantation (TAVI) has traditionally been supported intraprocedurally by transoesophageal echocardiography (TOE), transthoracic echocardiography (TTE) is increasingly being used. We evaluated echocardiographic imaging characteristics and clinical outcomes in patients who underwent TTE during TAVI (TTE-TAVI). METHODS AND RESULTS: A select team of dedicated sonographers and interventional echocardiographers performed TTE-TAVI in 278 patients, all of whom underwent TAVI through transfemoral access. We implanted the Medtronic EVOLUT R valve in 258 patients (92.8%). TTE images were acquired immediately pre-procedure by a dedicated sonographer in the cardiac catheterization laboratory with the patient in the supine position. TTE was then performed post deployment of TAVI. In the procedure, TTE image quality was fair or better in 249 (89.6%) cases. Color-flow Doppler was adequate or better in 275 (98.9%) cases. In 2 cases, paravalvular regurgitation (PVL) could not be assessed confidently by echocardiography due to poor image quality; in those cases, PVL was assessed by fluoroscopy, aortic root injection and invasive hemodynamics. Both TTE and invasive hemodynamics were used in the assessment of need for post-deployment stent ballooning (n = 23, 8.3%). TTE adequately recognized new pericardial effusion in 3 cases. No case required TOE conversion for image quality. There was only 1 case of intraprocedural TTE failing to recognize moderate PVL, without clinical implication. In 99% of patients, TTE-TAVI adequately assessed PVL compared with 24-h and 1-month follow-up TTE. CONCLUSIONS: With the current generation of TAVI, TTE-TAVI is adequate intraprocedurally when performed by specialized sonographers and dedicated cardiologists in a highly experienced TAVI center.

10.
Ann Thorac Surg ; 103(5): 1392-1398, 2017 May.
Artigo em Inglês | MEDLINE | ID: mdl-28242075

RESUMO

BACKGROUND: End-stage renal disease (ESRD) poses unique challenges in the treatment of patients with severe aortic stenosis. Although surgical valve replacement in ESRD patients has been associated with increased mortality, the outcomes from transcatheter aortic valve replacement (TAVR) are not clearly defined. METHODS: The CoreValve US Expanded Use Study is a prospective, nonrandomized study of TAVR in extreme-risk patients with comorbidities excluding them from the Pivotal Trial. We report on patients with ESRD. The primary endpoint was a composite of all-cause mortality or major stroke at 1 year. RESULTS: Ninety-six patients with ESRD underwent TAVR with the CoreValve (Medtronic, Minneapolis, MN) and have reached 1-year follow-up. Mean Society of Thoracic Surgeons Predicted Risk of Mortality score was 16.2% ± 8.4%. The rate of all-cause mortality or major stroke at 1 year was 30.3%. The all-cause mortality rate was 5.3% at 30 days and 30.3% at 1 year. The rate at 1 year of any stroke or transient ischemic attack was 2.1%; major vascular injury was 5.2%; and new permanent pacemaker was 26.8%. Valve performance improved postprocedure and remained improved at 1 year (effective orifice area 1.71 cm2, mean gradient 9.33 mm Hg) CONCLUSIONS: Early mortality in patients with ESRD is comparable to previously published data on extreme-risk patients without ESRD, but our data suggest a higher mortality rate at 1 year for ESRD patients, likely due to comorbid conditions. Stroke and major vascular injury are infrequent, and improved valve hemodynamics are maintained at 1 year.


Assuntos
Estenose da Valva Aórtica/mortalidade , Estenose da Valva Aórtica/cirurgia , Falência Renal Crônica/complicações , Complicações Pós-Operatórias/mortalidade , Substituição da Valva Aórtica Transcateter/mortalidade , Substituição da Valva Aórtica Transcateter/métodos , Idoso , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/diagnóstico por imagem , Causas de Morte , Comorbidade , Ecocardiografia , Feminino , Seguimentos , Humanos , Estimativa de Kaplan-Meier , Falência Renal Crônica/diagnóstico por imagem , Masculino , Complicações Pós-Operatórias/diagnóstico por imagem , Estudos Prospectivos , Terapia de Substituição Renal , Fatores de Risco , Taxa de Sobrevida
11.
JACC Cardiovasc Interv ; 10(10): 1034-1044, 2017 05 22.
Artigo em Inglês | MEDLINE | ID: mdl-28521921

RESUMO

OBJECTIVES: This study evaluated the safety and effectiveness of self-expanding transcatheter aortic valve replacement (TAVR) in patients with surgical valve failure (SVF). BACKGROUND: Self-expanding TAVR is superior to medical therapy for patients with severe native aortic valve stenosis at increased surgical risk. METHODS: The CoreValve U.S. Expanded Use Study was a prospective, nonrandomized study that enrolled 233 patients with symptomatic SVF who were deemed unsuitable for reoperation. Patients were treated with self-expanding TAVR and evaluated for 30-day and 1-year outcomes after the procedure. An independent core laboratory was used to evaluate serial echocardiograms for valve hemodynamics and aortic regurgitation. RESULTS: SVF occurred through stenosis (56.4%), regurgitation (22.0%), or a combination (21.6%). A total of 227 patients underwent attempted TAVR and successful TAVR was achieved in 225 (99.1%) patients. Patients were elderly (76.7 ± 10.8 years), had a Society of Thoracic Surgeons Predicted Risk of Mortality score of 9.0 ± 6.7%, and were severely symptomatic (86.8% New York Heart Association functional class III or IV). The all-cause mortality rate was 2.2% at 30 days and 14.6% at 1 year; major stroke rate was 0.4% at 30 days and 1.8% at 1 year. Moderate aortic regurgitation occurred in 3.5% of patients at 30 days and 7.4% of patients at 1 year, with no severe aortic regurgitation. The rate of new permanent pacemaker implantation was 8.1% at 30 days and 11.0% at 1 year. The mean valve gradient was 17.0 ± 8.8 mm Hg at 30 days and 16.6 ± 8.9 mm Hg at 1 year. Factors significantly associated with higher discharge mean aortic gradients were surgical valve size, stenosis as modality of SVF, and presence of surgical valve prosthesis patient mismatch (all p < 0.001). CONCLUSIONS: Self-expanding TAVR in patients with SVF at increased risk for surgery was associated with a low 1-year mortality and major stroke rate, significantly improved aortic valve hemodynamics, and low rates of moderate and no severe residual aortic regurgitation, with improved quality of life.


Assuntos
Insuficiência da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Implante de Prótese de Valva Cardíaca/instrumentação , Próteses Valvulares Cardíacas , Falha de Prótese , Substituição da Valva Aórtica Transcateter/instrumentação , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Insuficiência da Valva Aórtica/diagnóstico por imagem , Insuficiência da Valva Aórtica/mortalidade , Insuficiência da Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/mortalidade , Estenose da Valva Aórtica/fisiopatologia , Ecocardiografia , Feminino , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/mortalidade , Hemodinâmica , Humanos , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Qualidade de Vida , Recuperação de Função Fisiológica , Recidiva , Reoperação , Fatores de Risco , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/mortalidade , Resultado do Tratamento
12.
Ann Thorac Surg ; 101(3): e75-7, 2016 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-26897235

RESUMO

Surgical treatment of mitral stenosis with extreme calcification remains a challenge. Recently, the balloon-expandable valve prosthesis, anchored by radial force, offers a new option for these patients. We present 2 cases of transcatheter mitral valve replacement in patients with severe native mitral valve stenosis and annular calcification deemed too extensive for conventional surgical techniques.


Assuntos
Cateterismo Cardíaco/métodos , Implante de Prótese de Valva Cardíaca/métodos , Estenose da Valva Mitral/cirurgia , Idoso , Ecocardiografia Tridimensional , Ecocardiografia Transesofagiana , Feminino , Humanos , Estenose da Valva Mitral/diagnóstico por imagem , Desenho de Prótese
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa