Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 46
Filtrar
1.
Pacing Clin Electrophysiol ; 46(2): 198-200, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-36436209

RESUMO

The superior vena cava (SVC) is well described as one of the most common non-pulmonary vein (PV)-triggers for atrial tachyarrhythmias (ATA). In our study we evaluated a standardized approach for electrical isolation of the SVC from the right atrium using a horseshoe-shaped lesion set with optimized and contiguous ostial RF lesions. The results are promising, demonstrating a very high rate of acute SVC isolation in a safe and time efficient manner (mostly less than 10 min).


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Humanos , Veia Cava Superior/cirurgia , Fibrilação Atrial/cirurgia , Veias Pulmonares/cirurgia , Ablação por Cateter/métodos , Átrios do Coração
2.
J Cardiovasc Electrophysiol ; 33(2): 299-307, 2022 02.
Artigo em Inglês | MEDLINE | ID: mdl-34845776

RESUMO

INTRODUCTION: During left bundle branch area pacing (LBBAP) lead implantation, intermittent monitoring of unipolar pacing characteristics confirms LBB capture and can detect septal perforation. We aimed to demonstrate that continuous uninterrupted unipolar pacing from an inserted lead stylet (LS) is feasible and facilitates LBBAP implantation. METHODS: Thirty patients (mean age 76 ± 14 years) were implanted with a stylet-driven pacing lead (Biotronik Solia S60). In 10 patients (comparison-group) conventional implantation with interrupted unipolar pacing was performed, with comparison of unipolar pacing characteristics between LS and connector-pin (CP)-pacing after each rotation step. In 20 patients (uninterrupted-group) performance and safety of uninterrupted implantation during continuous pacing from the LS were evaluated. RESULTS: In the comparison group, LS and CP-pacing impedances were highly correlated (R2 = 0.95, p < .0001, bias 12 ± 37 Ω) with comparable sensed electrograms and paced QRS morphologies. In the uninterrupted group, continuous LS-pacing allowed beat-to-beat monitoring of impedance and QRS morphology to guide implantation. This resulted in successful LBBAP in all patients, after a mean of 1 ± 0 attempts, with mean threshold 0.81 ± 0.4 V, median sensing 6.5 mV [IQR 4.4-9.5], and mean impedance 624 ± 101 Ω. Positive LBBAP-criteria were seen in all patients with median paced QRS duration of 120 ms [IQR 112-152 ms] and median pLVAT 73 ms [IQR 68-80.5 ms]. No septal perforation occurred. CONCLUSION: Unipolar pacing from the LS allows accurate determination of pacing impedance and generates similar paced QRS morphologies and sensed electrograms to CP pacing. Continuous LS pacing allows real-time monitoring of impedance and paced QRS morphology, which facilitates safe and successful LBBAP lead implantation.


Assuntos
Estimulação Cardíaca Artificial , Septo Interventricular , Idoso , Idoso de 80 Anos ou mais , Fascículo Atrioventricular , Estimulação Cardíaca Artificial/efeitos adversos , Estimulação Cardíaca Artificial/métodos , Eletrocardiografia/métodos , Sistema de Condução Cardíaco , Humanos , Pessoa de Meia-Idade , Resultado do Tratamento
3.
J Cardiovasc Electrophysiol ; 30(9): 1416-1427, 2019 09.
Artigo em Inglês | MEDLINE | ID: mdl-31111557

RESUMO

BACKGROUND: The multiple wavelets and functional re-entry hypotheses are mechanistic theories to explain atrial fibrillation (AF). If valid, a chamber's ability to support AF should depend upon the left atrial size, conduction velocity (CV), and refractoriness. Measurement of these parameters could provide a new therapeutic target for AF. We investigated the relationship between left atrial effective conducting size (LAECS ), a function of area, CV and refractoriness, and AF vulnerability in patients undergoing AF ablation. METHODS AND RESULTS: Activation mapping was performed in patients with paroxysmal (n = 21) and persistent AF (n = 18) undergoing pulmonary vein isolation. Parameters used for calculating LAECS were: (a) left atrial body area (A); (b) effective refractory period (ERP); and (c) total activation time (T). Global CV was estimated as √A/T . Effective atrial conducting size was calculated as LAECS=A/(CV×ERP) . Post ablation, AF inducibility testing was performed. The critical LAECS required for multiple wavelet termination was determined from computational modeling. LAECS was greater in patients with persistent vs paroxysmal AF (4.4 ± 2.0 cm vs 3.2 ± 1.4 cm; P = .049). AF was inducible in 14/39 patients. LAECS was greater in AF-inducible patients (4.4 ± 1.8 cm vs 3.3 ± 1.7 cm; P = .035, respectively). The difference in LAECS between inducible and noninducible patients was significant in patients with persistent (P = .0046) but not paroxysmal AF (P = .6359). Computational modeling confirmed that LAECS > 4 cm was required for continuation of AF. CONCLUSIONS: LAECS measured post ablation was associated with AF inducibility in patients with persistent, but not paroxysmal AF. These data support a role for this method in electrical substrate assessment in AF patients.


Assuntos
Fibrilação Atrial/cirurgia , Função do Átrio Esquerdo , Ablação por Cateter , Modelos Cardiovasculares , Veias Pulmonares/cirurgia , Análise de Ondaletas , Potenciais de Ação , Adulto , Idoso , Idoso de 80 Anos ou mais , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/fisiopatologia , Remodelamento Atrial , Ablação por Cateter/efeitos adversos , Simulação por Computador , Feminino , Frequência Cardíaca , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Veias Pulmonares/fisiopatologia , Recidiva , Período Refratário Eletrofisiológico , Fatores de Tempo , Resultado do Tratamento
4.
J Cardiovasc Magn Reson ; 21(1): 62, 2019 10 10.
Artigo em Inglês | MEDLINE | ID: mdl-31597563

RESUMO

BACKGROUND: Ex-vivo cardiovascular magnetic resonance (CMR) imaging has played an important role in the validation of in-vivo CMR characterization of pathological processes. However, comparison between in-vivo and ex-vivo imaging remains challenging due to shape changes occurring between the two states, which may be non-uniform across the diseased heart. A novel two-step process to facilitate registration between ex-vivo and in-vivo CMR was developed and evaluated in a porcine model of chronic myocardial infarction (MI). METHODS: Seven weeks after ischemia-reperfusion MI, 12 swine underwent in-vivo CMR imaging with late gadolinium enhancement followed by ex-vivo CMR 1 week later. Five animals comprised the control group, in which ex-vivo imaging was undertaken without any support in the LV cavity, 7 animals comprised the experimental group, in which a two-step registration optimization process was undertaken. The first step involved a heart specific flexible 3D printed scaffold generated from in-vivo CMR, which was used to maintain left ventricular (LV) shape during ex-vivo imaging. In the second step, a non-rigid co-registration algorithm was applied to align in-vivo and ex-vivo data. Tissue dimension changes between in-vivo and ex-vivo imaging were compared between the experimental and control group. In the experimental group, tissue compartment volumes and thickness were compared between in-vivo and ex-vivo data before and after non-rigid registration. The effectiveness of the alignment was assessed quantitatively using the DICE similarity coefficient. RESULTS: LV cavity volume changed more in the control group (ratio of cavity volume between ex-vivo and in-vivo imaging in control and experimental group 0.14 vs 0.56, p < 0.0001) and there was a significantly greater change in the short axis dimensions in the control group (ratio of short axis dimensions in control and experimental group 0.38 vs 0.79, p < 0.001). In the experimental group, prior to non-rigid co-registration the LV cavity contracted isotropically in the ex-vivo condition by less than 20% in each dimension. There was a significant proportional change in tissue thickness in the healthy myocardium (change = 29 ± 21%), but not in dense scar (change = - 2 ± 2%, p = 0.034). Following the non-rigid co-registration step of the process, the DICE similarity coefficients for the myocardium, LV cavity and scar were 0.93 (±0.02), 0.89 (±0.01) and 0.77 (±0.07) respectively and the myocardial tissue and LV cavity volumes had a ratio of 1.03 and 1.00 respectively. CONCLUSIONS: The pattern of the morphological changes seen between the in-vivo and the ex-vivo LV differs between scar and healthy myocardium. A 3D printed flexible scaffold based on the in-vivo shape of the LV cavity is an effective strategy to minimize morphological changes in the ex-vivo LV. The subsequent non-rigid registration step further improved the co-registration and local comparison between in-vivo and ex-vivo data.


Assuntos
Imageamento por Ressonância Magnética , Modelos Anatômicos , Modelos Cardiovasculares , Infarto do Miocárdio/diagnóstico por imagem , Traumatismo por Reperfusão Miocárdica/diagnóstico por imagem , Impressão Tridimensional , Animais , Doença Crônica , Modelos Animais de Doenças , Infarto do Miocárdio/patologia , Infarto do Miocárdio/fisiopatologia , Traumatismo por Reperfusão Miocárdica/patologia , Traumatismo por Reperfusão Miocárdica/fisiopatologia , Miocárdio/patologia , Maleabilidade , Valor Preditivo dos Testes , Reprodutibilidade dos Testes , Sus scrofa , Função Ventricular Esquerda , Remodelação Ventricular
5.
Europace ; 21(12): 1817-1823, 2019 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-31793653

RESUMO

AIMS: A point-by-point workflow for pulmonary vein isolation (PVI) targeting pre-defined Ablation Index values (a composite of contact force, time, and power) and minimizing interlesion distance may optimize the creation of contiguous ablation lesions whilst minimizing scar formation. We aimed to compare ablation scar formation in patients undergoing PVI using this workflow to patients undergoing a continuous catheter drag workflow. METHODS AND RESULTS: Post-ablation cardiovascular magnetic resonance imaging was performed in patients undergoing 1st-time PVI using a parameter-guided point-by-point workflow (n = 26). Total left atrial scar burden and the width and continuity of the pulmonary vein encirclement were determined on analysis of atrial late gadolinium enhancement sequences. Comparison was made with a cohort of patients (n = 20) undergoing PVI using continuous drag lesions. Mean post-ablation scar burden and scar width were significantly lower in the point-by-point group than in the control group (6.6 ± 6.8% vs. 9.6 ± 5.0%, P = 0.03 and 7.9 ± 3.6 mm vs. 10.7 ± 2.3 mm, P = 0.003). More complete bilateral pulmonary vein encirclements were seen in the point-by-point group (P = 0.038). All patients achieved acute PVI. CONCLUSION: Pulmonary vein isolation using a point-by-point workflow is feasible and results in a lower scar burden and scar width with more complete pulmonary vein encirclements than a conventional drag lesion approach.


Assuntos
Fibrilação Atrial/cirurgia , Ablação por Cateter , Cicatriz/diagnóstico por imagem , Angiografia por Ressonância Magnética/métodos , Veias Pulmonares/diagnóstico por imagem , Veias Pulmonares/cirurgia , Técnicas de Imagem de Sincronização Cardíaca , Meios de Contraste , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Compostos Organometálicos , Fluxo de Trabalho
6.
Europace ; 21(9): 1432-1441, 2019 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-31219547

RESUMO

AIMS: Potential advantages of real-time magnetic resonance imaging (MRI)-guided electrophysiology (MR-EP) include contemporaneous three-dimensional substrate assessment at the time of intervention, improved procedural guidance, and ablation lesion assessment. We evaluated a novel real-time MR-EP system to perform endocardial voltage mapping and assessment of delayed conduction in a porcine ischaemia-reperfusion model. METHODS AND RESULTS: Sites of low voltage and slow conduction identified using the system were registered and compared to regions of late gadolinium enhancement (LGE) on MRI. The Sorensen-Dice similarity coefficient (DSC) between LGE scar maps and voltage maps was computed on a nodal basis. A total of 445 electrograms were recorded in sinus rhythm (range: 30-186) using the MR-EP system including 138 electrograms from LGE regions. Pacing captured at 103 sites; 47 (45.6%) sites had a stimulus-to-QRS (S-QRS) delay of ≥40 ms. Using conventional (0.5-1.5 mV) bipolar voltage thresholds, the sensitivity and specificity of voltage mapping using the MR-EP system to identify MR-derived LGE was 57% and 96%, respectively. Voltage mapping had a better predictive ability in detecting LGE compared to S-QRS measurements using this system (area under curve: 0.907 vs. 0.840). Using an electrical threshold of 1.5 mV to define abnormal myocardium, the total DSC, scar DSC, and normal myocardium DSC between voltage maps and LGE scar maps was 79.0 ± 6.0%, 35.0 ± 10.1%, and 90.4 ± 8.6%, respectively. CONCLUSION: Low-voltage zones and regions of delayed conduction determined using a real-time MR-EP system are moderately associated with LGE areas identified on MRI.


Assuntos
Doença do Sistema de Condução Cardíaco/diagnóstico por imagem , Doença do Sistema de Condução Cardíaco/fisiopatologia , Técnicas Eletrofisiológicas Cardíacas/métodos , Imagem por Ressonância Magnética Intervencionista/métodos , Traumatismo por Reperfusão Miocárdica/fisiopatologia , Taquicardia Ventricular/diagnóstico por imagem , Taquicardia Ventricular/fisiopatologia , Animais , Doença do Sistema de Condução Cardíaco/etiologia , Doença do Sistema de Condução Cardíaco/cirurgia , Ablação por Cateter , Modelos Animais de Doenças , Imageamento por Ressonância Magnética/métodos , Masculino , Traumatismo por Reperfusão Miocárdica/complicações , Traumatismo por Reperfusão Miocárdica/diagnóstico por imagem , Cirurgia Assistida por Computador , Sus scrofa , Suínos , Taquicardia Ventricular/etiologia , Taquicardia Ventricular/cirurgia
7.
Europace ; 20(suppl_3): iii55-iii68, 2018 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-30476055

RESUMO

AIMS: Treatments for persistent atrial fibrillation (AF) offer limited efficacy. One potential strategy aims to return the right atrium (RA) to sinus rhythm (SR) by ablating interatrial connections (IAC) to isolate the atria, but there is limited clinical data to evaluate this ablation approach. We aimed to use simulation to evaluate and predict patient-specific suitability for ablation of IAC to treat AF. METHODS AND RESULTS: Persistent AF was simulated in 12 patient-specific geometries, incorporating electrophysiological heterogeneity and fibres, with IAC at Bachmann's bundle, the coronary sinus, and fossa ovalis. Simulations were performed to test the effect of left atrial (LA)-to-RA frequency gradient and fibrotic remodelling on IAC ablation efficacy. During AF, we simulated ablation of one, two, or all three IAC, with or without pulmonary vein isolation and determined if this altered or terminated the arrhythmia. For models without structural remodelling, ablating all IAC terminated RA arrhythmia in 83% of cases. Models with the LA-to-RA frequency gradient removed had an increased success rate (100% success). Ablation of IACs is less effective in cases with fibrotic remodelling (interstitial fibrosis 50% success rate; combination remodelling 67%). Mean number of phase singularities in the RA was higher pre-ablation for IAC failure (success 0.6 ± 0.8 vs. failure 3.2 ± 2.5, P < 0.001). CONCLUSION: This simulation study predicts that IAC ablation is effective in returning the RA to SR for many cases. Patient-specific modelling approaches have the potential to stratify patients prior to ablation by predicting if drivers are located in the LA or RA. We present a platform for predicting efficacy and informing patient selection for speculative treatments.


Assuntos
Potenciais de Ação , Fibrilação Atrial/cirurgia , Função do Átrio Esquerdo , Função do Átrio Direito , Ablação por Cateter , Átrios do Coração/cirurgia , Frequência Cardíaca , Modelos Cardiovasculares , Modelagem Computacional Específica para o Paciente , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/fisiopatologia , Remodelamento Atrial , Ablação por Cateter/efeitos adversos , Tomada de Decisão Clínica , Fibrose , Átrios do Coração/diagnóstico por imagem , Átrios do Coração/fisiopatologia , Humanos , Imageamento por Ressonância Magnética , Seleção de Pacientes , Valor Preditivo dos Testes , Fatores de Tempo , Resultado do Tratamento
8.
Europace ; 20(FI2): f254-f262, 2018 09 01.
Artigo em Inglês | MEDLINE | ID: mdl-29294008

RESUMO

Aims: Magnetic resonance imaging (MRI) is the gold standard for defining myocardial substrate in 3D and can be used to guide ventricular tachycardia ablation. We describe the feasibility of using a prototype magnetic resonance-guided electrophysiology (MR-EP) system in a pre-clinical model to perform real-time MRI-guided epicardial mapping, ablation, and lesion imaging with active catheter tracking. Methods and results: Experiments were performed in vivo in pigs (n = 6) using an MR-EP guidance system research prototype (Siemens Healthcare) with an irrigated ablation catheter (Vision-MR, Imricor) and a dedicated electrophysiology recording system (Advantage-MR, Imricor). Following epicardial access, local activation and voltage maps were acquired, and targeted radiofrequency (RF) ablation lesions were delivered. Ablation lesions were visualized in real time during RF delivery using MR-thermometry and dosimetry. Hyper-acute and acute assessment of ablation lesions was also performed using native T1 mapping and late-gadolinium enhancement (LGE), respectively. High-quality epicardial bipolar electrograms were recorded with a signal-to-noise ratio of greater than 10:1 for a signal of 1.5 mV. During epicardial ablation, localized temperature elevation could be visualized with a maximum temperature rise of 35 °C within 2 mm of the catheter tip relative to remote myocardium. Decreased native T1 times were observed (882 ± 107 ms) in the lesion core 3-5 min after lesion delivery and relative location of lesions matched well to LGE. There was a good correlation between ablation lesion site on the iCMR platform and autopsy. Conclusion: The MR-EP system was able to successfully acquire epicardial voltage and activation maps in swine, deliver, and visualize ablation lesions, demonstrating feasibility for intraprocedural guidance and real-time assessment of ablation injury.


Assuntos
Ablação por Cateter/métodos , Técnicas Eletrofisiológicas Cardíacas/métodos , Ventrículos do Coração/cirurgia , Imagem por Ressonância Magnética Intervencionista , Potenciais de Ação , Animais , Cateteres Cardíacos , Ablação por Cateter/instrumentação , Meios de Contraste/administração & dosagem , Técnicas Eletrofisiológicas Cardíacas/instrumentação , Estudos de Viabilidade , Feminino , Gadolínio DTPA/administração & dosagem , Frequência Cardíaca , Ventrículos do Coração/diagnóstico por imagem , Ventrículos do Coração/patologia , Ventrículos do Coração/fisiopatologia , Modelos Animais , Valor Preditivo dos Testes , Sus scrofa , Fatores de Tempo
9.
Europace ; 20(12): 2028-2035, 2018 12 01.
Artigo em Inglês | MEDLINE | ID: mdl-29701778

RESUMO

Aims: Conducting gaps in lesion sets are a major reason for failure of ablation procedures. Voltage mapping and pace-capture have been proposed for intra-procedural identification of gaps. We aimed to compare gap size measured acutely and chronically post-ablation to macroscopic gap size in a porcine model. Methods and results: Intercaval linear ablation was performed in eight Göttingen minipigs with a deliberate gap of ∼5 mm left in the ablation line. Gap size was measured by interpolating ablation contact force values between ablation tags and thresholding at a low force cut-off of 5 g. Bipolar voltage mapping and pace-capture mapping along the length of the line were performed immediately, and at 2 months, post-ablation. Animals were euthanized and gap sizes were measured macroscopically. Voltage thresholds to define scar were determined by receiver operating characteristic analysis as <0.56 mV (acutely) and <0.62 mV (chronically). Taking the macroscopic gap size as gold standard, error in gap measurements were determined for voltage, pace-capture, and ablation contact force maps. All modalities overestimated chronic gap size, by 1.4 ± 2.0 mm (ablation contact force map), 5.1 ± 3.4 mm (pace-capture), and 9.5 ± 3.8 mm (voltage mapping). Error on ablation contact force map gap measurements were significantly less than for voltage mapping (P = 0.003, Tukey's multiple comparisons test). Chronically, voltage mapping and pace-capture mapping overestimated macroscopic gap size by 11.9 ± 3.7 and 9.8 ± 3.5 mm, respectively. Conclusion: Bipolar voltage and pace-capture mapping overestimate the size of chronic gap formation in linear ablation lesions. The most accurate estimation of chronic gap size was achieved by analysis of catheter-myocardium contact force during ablation.


Assuntos
Potenciais de Ação , Ablação por Cateter/efeitos adversos , Técnicas Eletrofisiológicas Cardíacas , Átrios do Coração/cirurgia , Frequência Cardíaca , Animais , Átrios do Coração/patologia , Átrios do Coração/fisiopatologia , Modelos Animais , Valor Preditivo dos Testes , Reprodutibilidade dos Testes , Suínos , Porco Miniatura , Falha de Tratamento
10.
J Cardiovasc Electrophysiol ; 28(9): 1028-1036, 2017 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-28639747

RESUMO

INTRODUCTION: Bipolar voltage is used during electroanatomic mapping to define abnormal myocardium, but the effect of activation rate on bipolar voltage is not known. We hypothesized that bipolar voltage may change in response to activation rate. By examining corresponding unipolar signals we sought to determine the mechanisms of such changes. METHODS AND RESULTS: LA extrastimulus mapping was performed during CS pacing in 10 patients undergoing first time paroxysmal atrial fibrillation ablation. Bipolar and unipolar electrograms were recorded using a PentaRay catheter (4-4-4 spacing) and indifferent IVC electrode, respectively. An S1S2 pacing protocol was delivered with extrastimulus coupling interval reducing from 350 to 200 milliseconds. At each recording site (119 ± 37 per LA), bipolar peak-to-peak voltage, unipolar peak to peak voltage and activation delay between unipole pairs was measured. Four patterns of bipolar voltage/extrastimulus coupling interval curves were seen: voltage attenuation with plateau voltage >1 mV (48 ± 15%) or <1 mV (22 ± 15%), and voltage unaffected by coupling interval with plateau voltage >1 mV (17 ± 10%) or <1 mV (13 ± 8%). Electrograms showing bipolar voltage attenuation were associated with significantly greater unipolar voltage attenuation at low (25 ± 28 mV/s vs. 9 ± 11 mV/s) and high (23 ± 29 mV/s vs. 6 ± 12 mV/s) plateau voltage sites (P < 0.001). There was a small but significant increase in conduction delay between unipole pairs at sites showing bipolar voltage attenuation (P = 0.026). CONCLUSIONS: Bipolar electrogram voltage is dependent on activation rate at a significant proportion of sites. Changes in unipolar voltage and timing underlie these effects. These observations have important implications for use of voltage mapping to delineate abnormal atrial substrate.


Assuntos
Fibrilação Atrial/cirurgia , Mapeamento Potencial de Superfície Corporal/métodos , Ablação por Cateter/métodos , Átrios do Coração/fisiopatologia , Sistema de Condução Cardíaco/fisiopatologia , Fibrilação Atrial/fisiopatologia , Feminino , Seguimentos , Sistema de Condução Cardíaco/cirurgia , Humanos , Masculino , Pessoa de Meia-Idade
13.
J Clin Med ; 13(8)2024 Apr 22.
Artigo em Inglês | MEDLINE | ID: mdl-38673710

RESUMO

The outcomes of persistent atrial fibrillation (AF) ablation are modest with various adjunctive strategies beyond pulmonary vein isolation (PVI) yielding largely disappointing results in randomised controlled trials. Linear ablation is a commonly employed adjunct strategy but is limited by difficulty in achieving durable bidirectional block, particularly at the mitral isthmus. Epicardial connections play a role in AF initiation and perpetuation. The ligament of Marshall has been implicated as a source of AF triggers and is known to harbour sympathetic and parasympathetic nerve fibres that contribute to AF perpetuation. Ethanol infusion into the Vein of Marshall, a remnant of the superior vena cava and key component of the ligament of Marshall, may eliminate these AF triggers and can facilitate the ease of obtaining durable mitral isthmus block. While early trials have demonstrated the potential of Vein of Marshall 'ethanolisation' to reduce arrhythmia recurrence after persistent AF ablation, further randomised trials are needed to fully determine the potential long-term outcome benefits afforded by this technique.

14.
Eur Heart J Case Rep ; 7(8): ytad382, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-37637094

RESUMO

Background: Patients with congenitally corrected transposition of the great arteries (ccTGA) are at risk of developing conduction disease and complete atrio-ventricular block and this risk increases after corrective cardiac surgery. However, the optimum pacing modality remains controversial. Case summary: Twelve years after a double-switch surgery with ventricular septal defect correction, a 16-year-old ccTGA female was referred with an indication for cardiac resynchronization therapy. In the absence of coronary sinus (CS) or direct access to the conduction system, several therapeutic options were considered. Finally, using a three-dimensional navigation system and customized sheaths, a left bundle branch area pacing (LBBAP) lead was successfully implanted. The implantation resulted in stable pacing parameters and positive haemodynamic changes. At 9-month follow-up, pacing parameters were stable and the patient reported a significant improvement in quality of life. Discussion: Cardiac resynchronization therapy in adults with repaired congenital heart disease remains challenging, especially in the absence of CS or direct access to the conduction system. In such a situation, LBBAP appears as an attractive alternative pacing modality. However, pre-operative management is critical to the success of the implantation.

15.
JACC Clin Electrophysiol ; 9(10): 2071-2081, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-37542487

RESUMO

BACKGROUND: Persistent shock-resistant atrial fibrillation (AF) is a challenging entity, with modest results from catheter ablation according to conventional survival analysis. OBJECTIVES: The aim of this study was to determine the effect of catheter ablation on atrial tachyarrhythmia (ATA) burden in persistent AF patients undergoing first-time ablation with the use of an implantable cardiac monitor (ICM). METHODS: Patients with drug-resistant ongoing persistent AF and at least 1 previous failed cardioversion were implanted with an ICM 2 months before the procedure. All patients underwent pulmonary vein isolation with or without additional substrate ablation depending on the presence of self-terminating AF on ICM and left atrium size. Median AF burden before and after ablation, off antiarrhythmic medication, was determined from ICM recordings after review by 2 independent investigators. RESULTS: Sixty patients were recruited (mean age 66 ± 9 years, 70% male). Mean left atrial diameter was 48 ± 6 mm and median CHA2DS2VASc score was 2. Ten patients (17%) unexpectedly demonstrated self-terminating AF before ablation. The median burden of ATA before ablation was 100% (95% CI: 19.6%-100%), decreasing to 0% (95% CI: 0%-95.8%) after ablation during the post-blanking follow-up period (median reduction 100%; 95% CI: 4%-100%; P < 0.001). Twenty-seven patients (45%) experienced recurrent ATA during 12-month follow-up. In these patients, median burden before ablation was 100% (95% CI: 26.9%-100%), decreasing to 11.4% (95% CI: 0.35%-99.7%) after ablation (P < 0.001). Quality of life improved significantly from baseline, driven by lack of recurrence. CONCLUSIONS: Patient-tailored catheter ablation results in a significant reduction in ATA burden (off antiarrhythmic medication) in shock-resistant persistent AF patients using ICMs implanted 2-months pre-procedure. These data suggest that conventional arrhythmia-free survival analysis does not capture the true impact of catheter ablation in this challenging cohort.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Humanos , Masculino , Pessoa de Meia-Idade , Idoso , Feminino , Qualidade de Vida , Resultado do Tratamento , Antiarrítmicos/uso terapêutico , Ablação por Cateter/métodos
16.
JACC Clin Electrophysiol ; 9(4): 511-522, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-36752467

RESUMO

BACKGROUND: Very high-power, short-duration (90-W/4-second) ablation for pulmonary vein isolation (PVI) may reduce procedural times. However, shorter applications with higher power may impact lesion quality. OBJECTIVES: In this multicenter, randomized controlled trial, the authors compared procedural efficiency, efficacy, and safety of PVI using 90-W/4-second ablation to 35/50-W ablation. METHODS: Patients with paroxysmal or persistent atrial fibrillation undergoing first-time PVI were randomized to pulmonary vein encirclement with contiguous applications using very high-power, short-duration applications (90 W over 4 seconds) or 35/50-W applications (titrated up to ablation index >550 anteriorly and >400 posteriorly). Prospective endpoints were procedural efficiency (procedure time and first-pass isolation), safety (including esophageal endoscopic evaluation), and 6-month effectiveness using repetitive Holter monitoring. RESULTS: A total of 180 patients were randomized, 90 to the 90-W group (mean age: 64.2 ± 8.9 years) and 90 to the 35/50-W group (mean age: 62.3 ± 10.8 years). Procedural time was shorter in the 90-W group vs the 35/50-W group (70 [IQR: 60-80] minutes vs 75 [IQR: 65-88.3] minutes; P = 0.009). A nonsignificant trend towards lower rates of first-pass isolation was seen in the 90-W group (83.9% vs 90%; P = 0.0852). No major complications were observed in both groups with esophageal injury occurring in 1 patient per group. At 6 months, 17% of patients in the 90-W group vs 15% in the 35/50-W group experienced recurrent arrhythmia (P = 0.681). CONCLUSIONS: Contiguous ablation using very high-power, short-duration applications results in a significant but modest reduction in procedure time with similar safety and 6-month efficacy vs a conventional approach. A hybrid approach combining both ablation modalities might be the most optimal strategy. (POWER PLUS [Very High Power Ablation in Patients With Atrial Fibrillation Schedule for a First Pulmonary Vein Isolation]; NCT04784013).


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Humanos , Pessoa de Meia-Idade , Idoso , Veias Pulmonares/cirurgia , Estudos Prospectivos , Resultado do Tratamento , Fibrilação Atrial/cirurgia , Esôfago/lesões , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos
17.
Circ Arrhythm Electrophysiol ; 16(11): e012043, 2023 11.
Artigo em Inglês | MEDLINE | ID: mdl-37921006

RESUMO

BACKGROUND: In patients with persistent atrial fibrillation (PersAF), catheter ablation aiming for pulmonary vein isolation (PVI) is associated with moderate clinical effectiveness. We investigated the benefit of continuing previously ineffective class 1C or 3 antiarrhythmic drug therapy (ADT) in the setting of a standardized PVI-only ablation strategy. METHODS: In this multicenter, randomized controlled study, patients with PersAF (≥7 days and <12 months) despite ADT were prospectively randomized 1:1 to PVI with ADT continued versus discontinued beyond the blanking period (ADT ON versus ADT OFF). Standardized catheter ablation was performed aiming for durable isolation with stable, contiguous, and optimized radio frequency applications encircling the pulmonary veins (CLOSE protocol). Clinical visits and 1-to-7-day Holter were performed at 3, 6, and 12 months. The primary end point was any documented atrial tachyarrhythmia lasting >30 seconds beyond 3 months. Prospectively defined secondary end points included repeat ablations, unscheduled arrhythmia-related visits, and quality of life among groups. RESULTS: Of 200 PersAF patients, 98 were assigned to ADT OFF and 102 to ADT ON. The longest atrial fibrillation episode qualifying for PersAF was 28 (10-90) versus 30 (11-90) days. Clinical characteristics and procedural characteristics were similar. Recurrence of atrial tachyarrhythmia was comparable in both groups (20% OFF versus 21.2% ON). No differences were observed in repeat ablations and unscheduled arrhythmia-related visits. Marked improvement in quality of life was observed in both groups. CONCLUSIONS: In patients with PersAF, there is no benefit in continuing previously ineffective ADT beyond the blanking period after catheter ablation. The high success rate of PVI-only might be explained by the high rate of durable isolation after optimized PVI and the early stage of PersAF (POWDER-AF2). REGISTRATION: URL: https://www.clinicaltrials.gov; Unique identifier: NCT03437356.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Humanos , Antiarrítmicos/efeitos adversos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/tratamento farmacológico , Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Furilfuramida , Pós/uso terapêutico , Veias Pulmonares/cirurgia , Qualidade de Vida , Recidiva , Taquicardia , Resultado do Tratamento , Estudos Prospectivos
18.
Front Cardiovasc Med ; 9: 1073239, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36568552

RESUMO

Recurrent atrial tachycardia (AT) is a common phenomenon after catheter ablation for AF, particularly in the setting of additional substrate ablation, with many studies demonstrating gap-related macro re-entrant AT (predominantly mitral and roof dependent) to be the dominant mechanism. Although multiple inducible ATs after ablation of the clinical AT are commonly described at repeat procedures, the optimal ablation strategy, and procedural endpoints are unclear in this setting. A recent randomized study addressing the question of non-inducibility as a procedural endpoint demonstrated no additional benefits to the ablation of all induced, non-clinical ATs, but it was limited by small numbers and high rates of non-inducibility. Nevertheless, once ablation of the clinical AT has been successfully performed, ensuring durable linear block and PV isolation may be sufficient for the prevention of further AT. Durable linear block, particularly at the mitral isthmus, is difficult to achieve but may be facilitated by the real-time evaluation of lesion quality and contiguity and the novel technique of vein of Marshall ethanol infusion. Large-scale, randomized trials are needed, nonetheless, to fully assess the optimal ablation strategy in the setting of recurrent AT post-AF ablation.

19.
J Interv Card Electrophysiol ; 65(1): 227-237, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-35737208

RESUMO

BACKGROUND: Atrial fibrillation (AF) is associated with atrial septal defects (ASDs), but the mechanism of arrhythmia in these patients is poorly understood. We hypothesised that right-sided atrial ectopy may predominate in this cohort. Here, we aimed to localise the origin of spontaneous and provoked atrial ectopy in ASD patients. METHODS: Following invasive calibration of P-wave axes, 24-h Holter monitoring was used to determine the chamber of origin of spontaneous atrial ectopy. Simultaneous electrogram recording from multiple intra-cardiac catheters was used to determine the chamber of origin of isoprenaline-provoked ectopy. Comparison was made to a group of non-congenital heart disease AF patients. RESULTS: Amongst ASD patients, a right-sided origin for spontaneous atrial ectopy was significantly more prevalent than a left-sided origin (24/30 patients with right-sided ectopy vs. 14/30 with left-sided ectopy, P = 0.015). Amongst AF patients, there was no difference in the prevalence of spontaneous right vs. left-sided ectopy. For isoprenaline-provoked ectopy, there was no significant difference in the proportions of patients with right-sided or left-sided ectopy in either group. CONCLUSIONS: When spontaneous atrial ectopy occurs in ASD patients, it is significantly more prevalent from a right-sided than left-sided origin. Isoprenaline infusion did not reveal the predilection for right-sided ectopy during electrophysiology study.


Assuntos
Fibrilação Atrial , Comunicação Interatrial , Estudos de Coortes , Eletrocardiografia Ambulatorial , Comunicação Interatrial/complicações , Comunicação Interatrial/diagnóstico por imagem , Humanos , Isoproterenol
20.
JACC Clin Electrophysiol ; 8(3): 367-376, 2022 03.
Artigo em Inglês | MEDLINE | ID: mdl-35331432

RESUMO

OBJECTIVES: In this study, the authors sought to investigate the added value of vein of Marshall ethanol infusion (VOMEt) as first step in facilitating radiofrequency (RF)-guided mitral isthmus (MI) block. BACKGROUND: Achieving MI block with the use of RF ablation is challenging. METHODS: Seventy patients planned for MI ablation were randomized 1:1 to VOMEt as a first step preceding RF (endocardial and epicardial, VOMFIRST group) vs RF ablation as a first step preceding VOMEt (RFFIRST group). The study end point was incidence of MI block after RF ablation and after the 2 steps. RESULTS: In VOMFIRST, VOMEt was successful in 30/35 patients (86%) resulting in a low-voltage area of 12 ± 7.4 cm2 and MI block in 2/35 patients (6%). VOMFIRST, compared with RFFIRST, was associated with higher incidence of MI block after endocardial (46% vs 11%; P < 0.001) and epicardial ablation (94% vs 43%; P < 0.001), with fewer endocardial applications (4 vs 11 vs 4; P < 0.001) and similar epicardial applications (7 vs 8; P = 0.68). Incidence of MI block after the 2 steps was 94% vs 63% (P = 0.001) in VOMFIRST vs RFFIRST, respectively. Additional touch-up RF ablation in both groups resulted in final MI block in all but 1 patient (99%). CONCLUSIONS: VOMEt as a first step in RF-guided MI line ablation significantly reduced the number of RF applications needed to achieve MI block, even if the sequence of the ablation steps did not affect the final incidence of block. (Evaluation of Vein of Marshall Ethanol Infusion During Left Atrial Linear Ablation in Patients With Persistent Atrial Fibrillation [MARSHALINE]; NCT04124328).


Assuntos
Fibrilação Atrial , Ablação por Cateter , Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Endocárdio , Etanol/uso terapêutico , Átrios do Coração , Humanos
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa