Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 163
Filtrar
1.
Graefes Arch Clin Exp Ophthalmol ; 262(1): 179-190, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37615697

RESUMO

PURPOSE   : To compare the efficacy and safety of the fixed-dose combination (FDC) of netarsudil 0.02%/latanoprost 0.005% ophthalmic solution (NET/LAT; Roclanda®) with bimatoprost 0.03%/timolol maleate 0.5% (BIM/TIM; Ganfort®) ophthalmic solution in the treatment of open-angle glaucoma (OAG) and ocular hypertension (OHT). METHODS: MERCURY-3 was a 6-month prospective, double-masked, randomized, multicenter, active-controlled, parallel-group, non-inferiority study. Patients (≥ 18 years) with a diagnosis of OAG or OHT in both eyes that was insufficiently controlled with topical medication (IOP ≥ 17 mmHg in ≥ 1 eye and < 28 mmHg in both eyes) were included. Following washout, patients were randomized to once-daily NET/LAT or BIM/TIM for up to 6 months; efficacy was assessed at Week 2, Week 4, and Month 3; safety was evaluated for 6 months. Comparison of NET/LAT relative to BIM/TIM for mean IOP at 08:00, 10:00, and 16:00 h was assessed at Week 2, Week 6, and Month 3. Non-inferiority of NET/LAT to BIM/TIM was defined as a difference of ≤ 1.5 mmHg at all nine time points through Month 3 and ≤ 1.0 mmHg at five or more of nine time points through Month 3. RESULTS: Overall, 430 patients were randomized (NET/LAT, n = 218; BIM/TIM, n = 212), and all received at least one dose of study medication. Efficacy analyses were performed at Month 3 on 388 patients (NET/LAT, n = 184; BIM/TIM, n = 204). NET/LAT demonstrated non-inferiority to BIM/TIM, with a between-treatment difference in IOP of ≤ 1.5 mmHg achieved at all time points and ≤ 1.0 mmHg at the majority of time points (six of nine) through Month 3. Mean diurnal IOP during the study ranged from 15.4 to 15.6 mmHg and 15.2 to 15.6 mmHg in the NET/LAT and BIM/TIM groups respectively, with no between-group statistically significant difference. No significant differences were observed in key secondary endpoints. No serious, treatment-related adverse events (AEs) were observed, and AEs were typically mild/moderate in severity. The most common treatment-related AEs were conjunctival hyperemia (NET/LAT, 30.7%; BIM/TIM, 9.0%) and cornea verticillata (NET/LAT, 11.0%; BIM/TIM, 0%). CONCLUSIONS: Once-daily NET/LAT was non-inferior to BIM/TIM in IOP reduction in OAG and OHT, with AEs consistent with previous findings. NET/LAT offers a compelling alternative FDC treatment option for OAG and OHT.


Assuntos
Benzoatos , Glaucoma de Ângulo Aberto , Hipertensão Ocular , beta-Alanina/análogos & derivados , Humanos , Glaucoma de Ângulo Aberto/diagnóstico , Glaucoma de Ângulo Aberto/tratamento farmacológico , Timolol/efeitos adversos , Bimatoprost/uso terapêutico , Latanoprosta/efeitos adversos , Estudos Prospectivos , Pressão Intraocular , Anti-Hipertensivos/efeitos adversos , Tonometria Ocular , Hipertensão Ocular/diagnóstico , Hipertensão Ocular/tratamento farmacológico , Soluções Oftálmicas , Resultado do Tratamento , Método Duplo-Cego
2.
Graefes Arch Clin Exp Ophthalmol ; 262(1): 149-160, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37530849

RESUMO

PURPOSE: To distinguish functioning from failed filtration blebs (FBs) implementing a deep learning (DL) model on slit-lamp images. METHODS: Retrospective, cross-sectional, multicenter study for development and validation of an artificial intelligence classification algorithm. The dataset consisted of 119 post-trabeculectomy FB images of whom we were aware of the surgical outcome. The ground truth labels were annotated and images splitted into three outcome classes: complete (C) or qualified success (Q), and failure (F). Images were prepared implementing various data cleaning and data transformations techniques. A set of DL models were trained using different ResNet architectures as the backbone. Transfer and ensemble learning were then applied to obtain a final combined model. Accuracy, sensitivity, specificity, area under the ROC curve, and area under the precision-recall curve were calculated to evaluate the final model. Kappa coefficient and P value on the accuracy measure were used to prove the statistical significance level. RESULTS: The DL approach reached good results in unraveling FB functionality. Overall, the model accuracy reached a score of 74%, with a sensitivity of 74% and a specificity of 87%. The area under the ROC curve was 0.8, whereas the area under the precision-recall curve was 0.74. The P value was equal to 0.00307, and the Kappa coefficient was 0.58. CONCLUSIONS: All considered metrics supported that the final DL model was able to discriminate functioning from failed FBs, with good accuracy. This approach could support clinicians in the patients' management after glaucoma surgery in absence of adjunctive clinical data.


Assuntos
Aprendizado Profundo , Glaucoma , Trabeculectomia , Humanos , Pressão Intraocular , Estudos Retrospectivos , Inteligência Artificial , Estudos Transversais , Trabeculectomia/métodos , Glaucoma/diagnóstico , Glaucoma/cirurgia
3.
Int J Mol Sci ; 25(11)2024 May 29.
Artigo em Inglês | MEDLINE | ID: mdl-38892100

RESUMO

To analyze in vivo scleral changes induced by MicroPulse transscleral laser therapy (MP-TLT) in refractory glaucoma using anterior segment-optical coherence tomography (AS-OCT). Forty-two candidate patients for MP-TLT were consecutively enrolled and underwent AS-OCT at baseline and after six months. MP-TLT success was defined as an intraocular pressure (IOP) reduction by one-third. The main outcome measures were the mean superior (S-), inferior (I-), and total (T-) intra-scleral hypo-reflective space area (MISHA: mm2) and scleral reflectivity (S-SR, I-SR, T-SR; arbitrary scale) as in vivo biomarkers of uveoscleral aqueous humor (AH) outflow. The IOP was the secondary outcome. The relations between the baseline-to-six months differences (D) of DS-MISHA, DI-MISHA, and DT-MISHA and DS-SR, DI-SR, DT-SR, and DIOP, were investigated. At 6 months, the median IOP reduction was 21% in the failures and 38% in the successes. The baseline S-MISHA, I-MISHA, and T-MISHA did not differ between the groups, while S-SR and T-SR were higher in the successes (p < 0.05). At six months, successful and failed MP-TLTs showed a 50% increase in S-MISHA (p < 0.001; p = 0.037), whereas I-SR and T-SR reduced only in the successes (p = 0.002; p = 0.001). When comparing DS-MISHA, DI-MISHA, and DT-MISHA and DS-SR, DI-SR, and DT-SR, there were no significant differences between the groups. In the successful procedures, DIOP was positively correlated with DT-MISHA and DI-MISHA (ρ = 0.438 and ρ = 0.490; p < 0.05). MP-TLT produced potentially advantageous modifications of the sclera in refractory glaucoma. Given the partial correlation between these modifications and post-treatment IOP reduction, our study confirmed that the activation of the uveoscleral AH outflow route could significantly contribute to the IOP lowering after MP-TLT.


Assuntos
Humor Aquoso , Glaucoma , Pressão Intraocular , Terapia a Laser , Esclera , Tomografia de Coerência Óptica , Humanos , Tomografia de Coerência Óptica/métodos , Esclera/cirurgia , Esclera/diagnóstico por imagem , Masculino , Feminino , Glaucoma/cirurgia , Glaucoma/diagnóstico por imagem , Pessoa de Meia-Idade , Terapia a Laser/métodos , Idoso , Humor Aquoso/metabolismo , Úvea/diagnóstico por imagem , Úvea/cirurgia , Adulto , Resultado do Tratamento
4.
Artigo em Inglês | MEDLINE | ID: mdl-38091058

RESUMO

BACKGROUND: Ocular surface (OS) disorders before glaucoma filtration surgery (GFS) have been considered to play a crucial role influencing the surgical outcome. Conversely, the impact of surgery itself on the OS is almost completely overlooked, though evidence suggest that ocular surface disease (OSD) may be induced in patients by GFS. This review analyzes the determinants involved in the OSD development after GFS, the clinical features and related consequences, the main diagnostic hallmarks, as well as the therapeutic strategies for its management. METHODS: The PubMed database was utilized for the literature examination. Keywords that were searched included ocular surface disease, glaucoma filtration surgery, filtration bleb, post-surgical management, and quality of life. RESULTS: After GFS, OSD is promoted by peri- and post-operative factors, such as the filtration bleb (FB) development, combined surgical approach with phacoemulsification, the use of antifibrotic agents and the reintroduction of antiglaucoma medications. This particular form of OSD that present similar clinical features to mild to moderate dry eye, can be named as post-glaucoma surgery-OSD (PGS-OSD). PGS-OSD may negatively affect the FB functionality, thus potentially hindering the disease control, and significantly worsen the patient quality of life (QOL). CONCLUSIONS: Clinicians are encouraged to routinely include the OS evaluation after GFS and to consider proper management when the occurrence of PGS-OSD worsen the patient's QOL or exert negative effects to the FB functionality. An outline summarizing the main risk factors and the most appropriate therapeutic options to mitigate the PGS-OSD was proposed to support the routine practice.

5.
Microsc Microanal ; : 1-8, 2022 Jan 07.
Artigo em Inglês | MEDLINE | ID: mdl-34991750

RESUMO

The present study investigated the corneal sub-basal nerve plexus (SNP) modifications in glaucoma. Ninety-five glaucomatous patients were enrolled and divided into Group 1 and 2, preserved and preservative-free mono-therapy (30 and 28 patients), and Group 3, multi-therapy (37). Thirty patients with dry eye disease (DED) and 32 healthy subjects (HC) served as controls. In vivo confocal microscopy evaluated the nerve fibers density (CNFD), length (CNFL), thickness (CNFT), branching density (CNBD), and dendritic cell density (DCD). CNFD, CNFL, and CNBD were reduced in Group 3 and DED compared to HC (p < 0.05). CNFL was reduced in Group 3 compared to Group 2 (p < 0.05), and in Group 1 compared to HC (p < 0.001). CNFD, CNBD, and CNFT did not differ between glaucomatous groups. DCD was higher in Group 3 and DED compared to HC and Group 2 (p < 0.01). Group 3 showed worse ocular surface disease index (OSDI) scores compared to Group 1, 2, and HC (p < 0.05). CNFL and DCD correlated with OSDI score in Group 3 (r = −0.658, p < 0.001; r = 0.699, p = 0.002). Medical therapy for glaucoma harms the corneal nerves, especially in multi-therapy regimens. Given the relations with the OSDI score, SNP changes seem features of glaucoma therapy-related OSD and negatively affects the patient's quality of life.

6.
Int J Mol Sci ; 23(19)2022 Sep 27.
Artigo em Inglês | MEDLINE | ID: mdl-36232676

RESUMO

Intraocular pressure (IOP) is considered an important modifiable risk factor for glaucoma, which is known as the second leading cause of blindness worldwide. However, lowering the IOP is not always sufficient to preserve vision due to other non-IOP-dependent mechanisms being involved. To improve outcomes, adjunctive therapies with IOP-independent targets are required. To date, no studies have shown the effect of citicoline on the trabecular meshwork (TM), even though it is known to possess neuroprotective/enhancement properties and multifactorial mechanisms of action. Given that reactive oxygen species seem to be involved in glaucomatous cascade, in this present study, an advanced millifluidic in vitro model was used to evaluate if citicoline could exert a valid TM protection against oxidative stress. To this end, the cellular behavior, in terms of viability, apoptosis, mitochondrial state, senescence and pro-inflammatory cytokines, on 3D human TM cells, treated either with H2O2 alone or cotreated with citicoline, was analyzed. Our preliminary in vitro results suggest a counteracting effect of citicoline eye drops against oxidative stress on TM cells, though further studies are necessary to explore citicoline's potential as a TM-target therapy.


Assuntos
Glaucoma , Malha Trabecular , Citidina Difosfato Colina/farmacologia , Citocinas/farmacologia , Glaucoma/tratamento farmacológico , Humanos , Peróxido de Hidrogênio/farmacologia , Pressão Intraocular , Soluções Oftálmicas/farmacologia , Estresse Oxidativo , Espécies Reativas de Oxigênio/farmacologia
7.
Ophthalmology ; 128(12): 1722-1735, 2021 12.
Artigo em Inglês | MEDLINE | ID: mdl-34153384

RESUMO

PURPOSE: To evaluate the ability of additional central testing locations to improve detection of macular visual field (VF) defects in glaucoma. DESIGN: Prospective cross-sectional study. PARTICIPANTS: Four hundred forty healthy people and 499 patients with glaucomatous optic neuropathy (GON) were tested with a fundus tracked perimeter (CMP; CenterVue) using a 24-2 grid with 12 additional macular locations (24-2+). METHODS: Glaucomatous optic neuropathy was identified based on expert evaluation of optic nerve head photographs and OCT scans, independently of the VF. We defined macular defects as locations with measurements outside the 5% and 2% normative limits on total deviation (TD) and pattern deviation (PD) maps within the VF central 10°. Classification was based on the total number of affected macular locations (overall detection) or the largest number of affected macular locations connected in a contiguous cluster (cluster detection). Criteria based on the number of locations and cluster size were used to obtain equivalent specificity between the 24-2 grid and the 24-2+ grids, calculated using false detections in the healthy cohort. Partial areas under the receiver operating characteristic curve (pAUCs) were also compared at specificities of 95% or more. MAIN OUTCOME MEASURES: Matched specificity comparison of the ability to detect glaucomatous macular defects between the 24-2 and 24-2+ grids. RESULTS: At matched specificity, cluster detection identified more macular defects with the 24-2+ grid compared with the 24-2 grid. For example, the mean increase in percentage of detection was 8% (95% confidence interval [CI], 5%-11%) and 10% (95% CI, 7%-13%) for 5% TD and PD maps, respectively, and 5% (95% CI, 2%-7%) and 6% (95% CI, 4%-8%) for the 2% TD and PD maps, respectively. Good agreement was found between the 2 grids. The improvement measured by pAUCs was also significant but generally small. The percentage of eyes with macular defects ranged from about 30% to 50%. Test time for the 24-2+ grid was longer (21% increase) for both cohorts. Between 74% and 98% of defects missed by the 24-2 grid had at least 1 location with sensitivity of < 20 dB. CONCLUSIONS: Visual field examinations with additional macular locations can improve the detection of macular defects in GON modestly without loss of specificity when appropriate criteria are selected.


Assuntos
Glaucoma de Ângulo Aberto/diagnóstico , Macula Lutea/patologia , Doenças do Nervo Óptico/diagnóstico , Testes de Campo Visual/métodos , Campos Visuais/fisiologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Área Sob a Curva , Estudos de Casos e Controles , Estudos Transversais , Feminino , Glaucoma de Ângulo Aberto/fisiopatologia , Humanos , Pressão Intraocular/fisiologia , Masculino , Pessoa de Meia-Idade , Disco Óptico/fisiopatologia , Doenças do Nervo Óptico/fisiopatologia , Estudos Prospectivos , Curva ROC
8.
Int J Mol Sci ; 22(11)2021 May 31.
Artigo em Inglês | MEDLINE | ID: mdl-34072647

RESUMO

Steroid-induced glaucoma is a severe pathological condition, sustained by a rapidly progressive increase in intraocular pressure (IOP), which is diagnosed in a subset of subjects who adhere to a glucocorticoid (GC)-based therapy. Molecular and clinical studies suggest that either natural or synthetic GCs induce a severe metabolic dysregulation of Trabecular Meshwork Cells (TMCs), an endothelial-derived histotype with phagocytic and secretive functions which lay at the iridocorneal angle in the anterior segment of the eye. Since TMCs physiologically regulate the composition and architecture of trabecular meshwork (TM), which is the main outflow pathway of aqueous humor, a fluid which shapes the eye globe and nourishes the lining cell types, GCs are supposed to trigger a pathological remodeling of the TM, inducing an IOP increase and retina mechanical compression. The metabolic dysregulation of TMCs induced by GCs exposure has never been characterized at the molecular detail. Herein, we report that, upon dexamethasone exposure, a TMCs strain develops a marked inhibition of the autophagosome biogenesis pathway through an enhanced turnover of two members of the Ulk-1 complex, the main platform for autophagy induction, through the Ubiquitin Proteasome System (UPS).


Assuntos
Proteína Homóloga à Proteína-1 Relacionada à Autofagia/metabolismo , Autofagia/efeitos dos fármacos , Dexametasona/farmacologia , Peptídeos e Proteínas de Sinalização Intracelular/metabolismo , Complexos Multiproteicos/metabolismo , Malha Trabecular/efeitos dos fármacos , Malha Trabecular/metabolismo , Apoptose/efeitos dos fármacos , Autofagia/genética , Proteína Homóloga à Proteína-1 Relacionada à Autofagia/genética , Proliferação de Células/efeitos dos fármacos , Dexametasona/efeitos adversos , Suscetibilidade a Doenças , Glaucoma/etiologia , Glaucoma/metabolismo , Glaucoma/fisiopatologia , Humanos , Peptídeos e Proteínas de Sinalização Intracelular/genética , Complexo de Endopeptidases do Proteassoma/metabolismo
9.
Int J Mol Sci ; 22(15)2021 Jul 27.
Artigo em Inglês | MEDLINE | ID: mdl-34360760

RESUMO

Retinal ganglion cells (RGCs) are a population of neurons of the central nervous system (CNS) extending with their soma to the inner retina and with their axons to the optic nerve. Glaucoma represents a group of neurodegenerative diseases where the slow progressive death of RGCs results in a permanent loss of vision. To date, although Intra Ocular Pressure (IOP) is considered the main therapeutic target, the precise mechanisms by which RGCs die in glaucoma have not yet been clarified. In fact, Primary Open Angle Glaucoma (POAG), which is the most common glaucoma form, also occurs without elevated IOP. This present review provides a summary of some pathological conditions, i.e., axonal transport blockade, glutamate excitotoxicity and changes in pro-inflammatory cytokines along the RGC projection, all involved in the glaucoma cascade. Moreover, neuro-protective therapeutic approaches, which aim to improve RGC degeneration, have also been taken into consideration.


Assuntos
Glaucoma , Neuroproteção , Células Ganglionares da Retina , Animais , Transporte Axonal , Axônios/metabolismo , Axônios/patologia , Modelos Animais de Doenças , Glaucoma/metabolismo , Glaucoma/patologia , Glaucoma/terapia , Humanos , Nervo Óptico/metabolismo , Nervo Óptico/patologia , Células Ganglionares da Retina/metabolismo , Células Ganglionares da Retina/patologia
10.
Int J Mol Sci ; 22(22)2021 Nov 09.
Artigo em Inglês | MEDLINE | ID: mdl-34830007

RESUMO

Primary Open-Angle Glaucoma (POAG) is a neurodegenerative disease, and its clinical outcomes lead to visual field constriction and blindness. POAG's etiology is very complex and its pathogenesis is mainly explained through both mechanical and vascular theories. The trabecular meshwork (TM), the most sensitive tissue of the eye anterior segment to oxidative stress (OS), is the main tissue involved in early-stage POAG, characterized by an increase in pressure. Preclinical assessments of neuroprotective drugs on animal models have not always shown correspondence with human clinical studies. In addition, intra-ocular pressure management after a glaucoma diagnosis does not always prevent blindness. Recently, we have been developing an innovative in vitro 3Dadvanced human trabecular cell model on a millifluidicplatform as a tool to improve glaucoma studies. Herein, we analyze the effects of prolonged increased pressure alone and, in association with OS, on such in vitro platform. Moreover, we verify whethersuch damaged TM triggers apoptosis on neuron-like cells. The preliminary results show that TM cells are less sensitive to pressure elevation than OS, and OS-damaging effects were worsened by the pressure increase. The stressed TM releases harmful signals, which increase apoptosis stimuli on neuron-like cells, suggesting its pivotal role in the glaucoma cascade.


Assuntos
Glaucoma de Ângulo Aberto/tratamento farmacológico , Fármacos Neuroprotetores/farmacologia , Estresse Oxidativo/efeitos dos fármacos , Malha Trabecular/efeitos dos fármacos , Apoptose/efeitos dos fármacos , Linhagem Celular , Olho/metabolismo , Olho/patologia , Glaucoma de Ângulo Aberto/genética , Glaucoma de Ângulo Aberto/metabolismo , Glaucoma de Ângulo Aberto/patologia , Humanos , Pressão Intraocular/efeitos dos fármacos , Malha Trabecular/metabolismo , Malha Trabecular/patologia
11.
Graefes Arch Clin Exp Ophthalmol ; 258(8): 1763-1770, 2020 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-32415535

RESUMO

PURPOSE: To describe and compare the conjunctival filtering bleb features after XEN gel implantation and trabeculectomy using anterior segment optical coherence tomography (AS-OCT) and in vivo confocal microscopy (IVCM). METHODS: Fifty-two patients who underwent completely successful trabeculectomy (24 eyes) or completely successful XEN gel implantation (28 eyes) were consecutively enrolled. At the sixth-month follow-up, filtering blebs were analyzed with AS-OCT and IVCM. The main outcomes were the following: (i) bleb-wall epithelium cyst-like structure density and area (BECSD, BSCSA), (ii) bleb-wall sub-epithelium cyst-like structure density and area (BSCSD, BSCSA,), (iii) bleb-wall thickness (BT), (iv) bleb-wall epithelial thickness (BET), (v) bleb-wall reflectivity (BR), and (vi) bleb height (BH), for AS-OCT. Mean microcyst density (MMD) and area (MMA) and stromal meshwork reflectivity (SMR) were the IVCM outcomes. RESULTS: Six-month intraocular pressure was 11.46 ± 3.09 and 10.06 ± 3.39 mmHg in the XEN gel implantation and trabeculectomy, respectively (p > 0.05). At AS-OCT, XEN gel blebs showed lower BH, BT, BET, BR, (p < 0.001), and BECSA values (p < 0.005), and a higher BECSD (p < 0.05) compared with trabeculectomy blebs. At IVCM, MMA and SMR values were lower in the XEN gel implantation, compared with trabeculectomy (p < 0.05). BECSD and BSCSD negatively correlated with BR (p < 0.01; r = - 0.110; p < 0.01; r = - 0.249), whereas BR strongly correlated with SMR (p < 0.001; r = 0.819). CONCLUSION: Successful filtering blebs after XEN gel implantation appeared flatter and thinner, with a higher number of epithelial cysts and a hypo-reflective bleb wall compared with trabeculectomy. These aspects may depend on the different intra-operative tissue manipulation and/or on different aqueous humor dynamics in the sub-conjunctiva between surgeries.


Assuntos
Segmento Anterior do Olho/patologia , Túnica Conjuntiva/patologia , Glaucoma/cirurgia , Imageamento Tridimensional/métodos , Implantação de Prótese/métodos , Tomografia de Coerência Óptica/métodos , Trabeculectomia/métodos , Idoso , Estudos Transversais , Feminino , Seguimentos , Glaucoma/diagnóstico , Glaucoma/fisiopatologia , Humanos , Pressão Intraocular/fisiologia , Masculino , Microscopia Confocal , Pessoa de Meia-Idade , Desenho de Prótese , Estudos Retrospectivos
12.
Graefes Arch Clin Exp Ophthalmol ; 258(6): 1237-1251, 2020 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-32221692

RESUMO

BACKGROUND/AIMS: To evaluate diurnal variations in optic nerve head (ONH) vessel density assessed by optical coherence tomography angiography (OCT-A) in healthy subjects, ocular hypertension (OHT), and open-angle glaucoma (OAG) patients. METHODS: Forty subjects (OAG, 21; OHT, 6; healthy, 13) were assessed for vessel density percentage (VD%) and flow index in the ONH (NH VD%, NH index), and in the radial peripapillary capillary layer (RPC VD%, RPC index) at 9:00, 11:00, 14:00, 16:00, and 18:00 on a single day. Repeated measures ANOVAs were used to test for changes in the parameters measured at multiple time points. RESULTS: All OCT-A parameters analyzed at the different time points were statistically lower in the OAG patients compared to both the OHT and healthy groups (p < 0.05). In the OAG group, the NH index, RPC index, NH VD%, and RPC VD% were statistically lower at 18:00 compared to 14:00, and the RPC VD% was statistically lower at 9:00 than 14:00. In the OHT group, the RPC index was statistically lower at 9:00 than 11:00. In the healthy group, the NH VD% and RPC VD% were statistically lower at 16:00 than 18:00, and the RPC index was statistically lower at 9:00 than 11:00. No other statistically significant difference was found in none of the three groups comparing any other time point (p > 0.05). CONCLUSION: In healthy subjects, OHT and OAG patients, the variations in the OCT-A derived parameters were relatively small. These results suggest that in the clinical practice the OCT-A assessment can be performed independently of the time of the day, contrasting IOP evaluation.


Assuntos
Ritmo Circadiano/fisiologia , Glaucoma de Ângulo Aberto/fisiopatologia , Disco Óptico/irrigação sanguínea , Vasos Retinianos/fisiopatologia , Adulto , Idoso , Feminino , Angiofluoresceinografia , Glaucoma de Ângulo Aberto/diagnóstico , Humanos , Pressão Intraocular/fisiologia , Masculino , Pessoa de Meia-Idade , Fibras Nervosas/patologia , Hipertensão Ocular/diagnóstico , Hipertensão Ocular/fisiopatologia , Células Ganglionares da Retina/patologia , Tomografia de Coerência Óptica , Tonometria Ocular , Campos Visuais
13.
Clin Exp Ophthalmol ; 48(9): 1192-1200, 2020 12.
Artigo em Inglês | MEDLINE | ID: mdl-32918375

RESUMO

IMPORTANCE: To analyse the preoperative conjunctival thickness in glaucomatous patients undergoing filtration surgery (FS), using optical coherence tomography (OCT). BACKGROUND: The conjunctival status represents one of the most critical determinants of the FS outcome. DESIGN: Retrospective study. PARTICIPANTS: Sixty-seven patients candidate to FS for uncontrolled glaucoma were enrolled. METHODS: OCT was performed at the superior bulbar conjunctiva before FS, and at bleb site at the last follow-up (LF-up) after surgery. MAIN OUTCOME MEASURES: Preoperative full, epithelial, and stromal conjunctival thickness (FCT, CET, CST) and reflectivity (CR), and LF-up bleb-wall thickness (BT), reflectivity (BR) and intraocular pressure (IOP), were the major outcomes. The relations between preoperative parameters and LF-up-IOP, BT and BR were calculated. RESULTS: FS was completely successful in 23 patients (group 1), successful with medications in 22 (group 2), and failed in 22 (group 3). FCT, CET and CST were lower, whereas CR higher, in group 3 compared to groups 1 and 2 (P < .05); BT was lower (P < .001), whereas BR higher (P < .05) in group 3 compared to group 1. FCT and CST were predictors of FS outcome with lower thickness associated with increased odds of failure (odds ratio 0.922, P = .08; 0.941, P = .025). LF-up-IOP inversely correlated with FCT and CST (r = -0.447, P = .003; r = -0.408, P = .007), whereas positively correlated with CR (r = 0.789, P < .001). CONCLUSIONS AND RELEVANCE: Preoperative conjunctival thickness and reflectivity show significant correlations with the FS outcome, both in terms of IOP and bleb-wall features. Therefore, they may be proposed as predictive imaging biomarkers to estimate the risk of filtration failure.


Assuntos
Cirurgia Filtrante , Glaucoma , Trabeculectomia , Segmento Anterior do Olho/diagnóstico por imagem , Biomarcadores , Túnica Conjuntiva/diagnóstico por imagem , Glaucoma/diagnóstico , Glaucoma/cirurgia , Humanos , Estudos Retrospectivos , Tomografia de Coerência Óptica
14.
Ophthalmology ; 126(2): 242-251, 2019 02.
Artigo em Inglês | MEDLINE | ID: mdl-30114416

RESUMO

PURPOSE: To evaluate relative diagnostic precision and test-retest variability of 2 devices, the Compass (CMP, CenterVue, Padova, Italy) fundus perimeter and the Humphrey Field Analyzer (HFA, Zeiss, Dublin, CA), in detecting glaucomatous optic neuropathy (GON). DESIGN: Multicenter, cross-sectional, case-control study. PARTICIPANTS: We sequentially enrolled 499 patients with glaucoma and 444 normal subjects to analyze relative precision. A separate group of 44 patients with glaucoma and 54 normal subjects was analyzed to assess test-retest variability. METHODS: One eye of recruited subjects was tested with the index tests: HFA (Swedish interactive thresholding algorithm [SITA] standard strategy) and CMP (Zippy Estimation by Sequential Testing [ZEST] strategy), 24-2 grid. The reference test for GON was specialist evaluation of fundus photographs or OCT, independent of the visual field (VF). For both devices, linear regression was used to calculate the sensitivity decrease with age in the normal group to compute pointwise total deviation (TD) values and mean deviation (MD). We derived 5% and 1% pointwise normative limits. The MD and the total number of TD values below 5% (TD 5%) or 1% (TD 1%) limits per field were used as classifiers. MAIN OUTCOME MEASURES: We used partial receiver operating characteristic (pROC) curves and partial area under the curve (pAUC) to compare the diagnostic precision of the devices. Pointwise mean absolute deviation and Bland-Altman plots for the mean sensitivity (MS) were computed to assess test-retest variability. RESULTS: Retinal sensitivity was generally lower with CMP, with an average mean difference of 1.85±0.06 decibels (dB) (mean ± standard error, P < 0.001) in healthy subjects and 1.46±0.05 dB (mean ± standard error, P < 0.001) in patients with glaucoma. Both devices showed similar discriminative power. The MD metric had marginally better discrimination with CMP (pAUC difference ± standard error, 0.019±0.009, P = 0.035). The 95% limits of agreement for the MS were reduced by 13% in CMP compared with HFA in participants with glaucoma and by 49% in normal participants. Mean absolute deviation was similar, with no significant differences. CONCLUSIONS: Relative diagnostic precision of the 2 devices is equivalent. Test-retest variability of MS for CMP was better than for HFA.


Assuntos
Glaucoma de Ângulo Aberto/diagnóstico , Doenças do Nervo Óptico/diagnóstico , Transtornos da Visão/diagnóstico , Testes de Campo Visual/instrumentação , Campos Visuais , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Algoritmos , Área Sob a Curva , Estudos de Casos e Controles , Estudos Transversais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Fibras Nervosas/patologia , Curva ROC , Reprodutibilidade dos Testes , Retina/fisiologia , Células Ganglionares da Retina/patologia , Sensibilidade e Especificidade , Adulto Jovem
16.
Ophthalmology ; 123(5): 939-49, 2016 May.
Artigo em Inglês | MEDLINE | ID: mdl-26891880

RESUMO

TOPIC: Macular parameters have been proposed as an alternative to retinal nerve fiber layer (RNFL) parameters to diagnose glaucoma. Comparing the diagnostic accuracy of macular parameters, specifically the ganglion cell complex (GCC) and ganglion cell inner plexiform layer (GCIPL), with the accuracy of RNFL parameters for detecting manifest glaucoma is important to guide clinical practice and future research. METHODS: Studies using spectral domain optical coherence tomography (SD OCT) and reporting macular parameters were included if they allowed the extraction of accuracy data for diagnosing manifest glaucoma, as confirmed with automated perimetry or a clinician's optic nerve head (ONH) assessment. Cross-sectional cohort studies and case-control studies were included. The QUADAS 2 tool was used to assess methodological quality. Only direct comparisons of macular versus RNFL parameters (i.e., in the same study) were conducted. Summary sensitivity and specificity of each macular or RNFL parameter were reported, and the relative diagnostic odds ratio (DOR) was calculated in hierarchical summary receiver operating characteristic (HSROC) models to compare them. RESULTS: Thirty-four studies investigated macular parameters using RTVue OCT (Optovue Inc., Fremont, CA) (19 studies, 3094 subjects), Cirrus OCT (Carl Zeiss Meditec Inc., Dublin, CA) (14 studies, 2164 subjects), or 3D Topcon OCT (Topcon, Inc., Tokyo, Japan) (4 studies, 522 subjects). Thirty-two of these studies allowed comparisons between macular and RNFL parameters. Studies generally reported sensitivities at fixed specificities, more commonly 0.90 or 0.95, with sensitivities of most best-performing parameters between 0.65 and 0.75. For all OCT devices, compared with RNFL parameters, macular parameters were similarly or slightly less accurate for detecting glaucoma at the highest reported specificity, which was confirmed in analyses at the lowest specificity. Included studies suffered from limitations, especially the case-control study design, which is known to overestimate accuracy. However, this flaw is less relevant as a source of bias in direct comparisons conducted within studies. CONCLUSIONS: With the use of OCT, RNFL parameters are still preferable to macular parameters for diagnosing manifest glaucoma, but the differences are small. Because of high heterogeneity, direct comparative or randomized studies of OCT devices or OCT parameters and diagnostic strategies are essential.


Assuntos
Glaucoma/diagnóstico , Macula Lutea/patologia , Fibras Nervosas/patologia , Disco Óptico/patologia , Células Ganglionares da Retina/patologia , Humanos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Tomografia de Coerência Óptica
17.
Graefes Arch Clin Exp Ophthalmol ; 254(6): 1151-8, 2016 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-26907933

RESUMO

PURPOSE: The aim of this study was to investigate the efficacy and safety of Bimatoprost Unit Dose Preservative Free (BUDPF) and Latanoprost Unit Dose Preservative Free (LUDPF). METHODS: A prospective, randomized, investigator-masked, cross-over comparison was used. Inclusion criteria were ocular hypertension (OHT) or open-angle glaucoma (OAG) with a maximum intraocular pressure (IOP) of 21 mmHg on a preserved prostaglandin monotherapy. After 6 weeks washout, patients were randomized to BUDPF or LUDPF for 3 months and then switched to the other treatment for 3 months. IOP curves were performed at baseline and after each treatment period. Statistical analysis was performed in a R programming environment. Linear mixed modeling was used to account for repeated measures on the same subject and clustering of observations from the same center. Safety outcomes included visual acuity, adverse events, slit-lamp biomicroscopy, ocular tolerability, and optic nerve assessment. RESULTS: Analysis at 6 months (primary outcome) showed a 1.6 ± 0.5-mmHg difference in IOP values between LUDPF and BUDPF (p < 0.01). A mean intra-subject IOP difference of 0.9 ± 0.2 mmHg (LUDPF - BUDPF) was observed (p < 0.01).. Significant differences in IOP were observed for both drugs at 3 and at 6 months compared to baseline: -4,0 ± 0.5 mmHg for both BUDPF and LUDPF at 3 months (p < 0.01 for both drugs; p = 0.32 between the two drugs); -5.2 ± 0.5 and -3.4 ± 0.5 mmHg for BUDPF and LUDPF, respectively (both p < 0.01), at 6 months. Both drugs were tolerated well, the only statistically significant difference being lower hyperemia scores for LUDPF (albeit low for both drugs). CONCLUSIONS: This study demonstrates a superior efficacy of BUDPF over LUDPF in lowering IOP. The results are consistent both in the parallel comparison between the two treatment groups at 6 months as well as in the intra-subject pressure comparison.


Assuntos
Anti-Hipertensivos/uso terapêutico , Bimatoprost/uso terapêutico , Glaucoma de Ângulo Aberto/tratamento farmacológico , Prostaglandinas F Sintéticas/uso terapêutico , Estudos Cross-Over , Método Duplo-Cego , Glaucoma de Ângulo Aberto/fisiopatologia , Humanos , Pressão Intraocular/efeitos dos fármacos , Pressão Intraocular/fisiologia , Latanoprosta , Hipertensão Ocular/tratamento farmacológico , Hipertensão Ocular/fisiopatologia , Soluções Oftálmicas , Conservantes Farmacêuticos , Estudos Prospectivos , Lâmpada de Fenda , Tonometria Ocular , Resultado do Tratamento , Acuidade Visual/fisiologia
18.
Cochrane Database Syst Rev ; (11): CD008803, 2015 Nov 30.
Artigo em Inglês | MEDLINE | ID: mdl-26618332

RESUMO

BACKGROUND: The diagnosis of glaucoma is traditionally based on the finding of optic nerve head (ONH) damage assessed subjectively by ophthalmoscopy or photography or by corresponding damage to the visual field assessed by automated perimetry, or both. Diagnostic assessments are usually required when ophthalmologists or primary eye care professionals find elevated intraocular pressure (IOP) or a suspect appearance of the ONH. Imaging tests such as confocal scanning laser ophthalmoscopy (HRT), optical coherence tomography (OCT) and scanning laser polarimetry (SLP, as used by the GDx instrument), provide an objective measure of the structural changes of retinal nerve fibre layer (RNFL) thickness and ONH parameters occurring in glaucoma. OBJECTIVES: To determine the diagnostic accuracy of HRT, OCT and GDx for diagnosing manifest glaucoma by detecting ONH and RNFL damage. SEARCH METHODS: We searched several databases for this review. The most recent searches were on 19 February 2015. SELECTION CRITERIA: We included prospective and retrospective cohort studies and case-control studies that evaluated the accuracy of OCT, HRT or the GDx for diagnosing glaucoma. We excluded population-based screening studies, since we planned to consider studies on self-referred people or participants in whom a risk factor for glaucoma had already been identified in primary care, such as elevated IOP or a family history of glaucoma. We only considered recent commercial versions of the tests: spectral domain OCT, HRT III and GDx VCC or ECC. DATA COLLECTION AND ANALYSIS: We adopted standard Cochrane methods. We fitted a hierarchical summary ROC (HSROC) model using the METADAS macro in SAS software. After studies were selected, we decided to use 2 x 2 data at 0.95 specificity or closer in meta-analyses, since this was the most commonly-reported level. MAIN RESULTS: We included 106 studies in this review, which analysed 16,260 eyes (8353 cases, 7907 controls) in total. Forty studies (5574 participants) assessed GDx, 18 studies (3550 participants) HRT, and 63 (9390 participants) OCT, with 12 of these studies comparing two or three tests. Regarding study quality, a case-control design in 103 studies raised concerns as it can overestimate accuracy and reduce the applicability of the results to daily practice. Twenty-four studies were sponsored by the manufacturer, and in 15 the potential conflict of interest was unclear.Comparisons made within each test were more reliable than those between tests, as they were mostly based on direct comparisons within each study.The Nerve Fibre Indicator yielded the highest accuracy (estimate, 95% confidence interval (CI)) among GDx parameters (sensitivity: 0.67, 0.55 to 0.77; specificity: 0.94, 0.92 to 0.95). For HRT measures, the Vertical Cup/Disc (C/D) ratio (sensitivity: 0.72, 0.60 to 0.68; specificity: 0.94, 0.92 to 0.95) was no different from other parameters. With OCT, the accuracy of average RNFL retinal thickness was similar to the inferior sector (0.72, 0.65 to 0.77; specificity: 0.93, 0.92 to 0.95) and, in different studies, to the vertical C/D ratio.Comparing the parameters with the highest diagnostic odds ratio (DOR) for each device in a single HSROC model, the performance of GDx, HRT and OCT was remarkably similar. At a sensitivity of 0.70 and a high specificity close to 0.95 as in most of these studies, in 1000 people referred by primary eye care, of whom 200 have manifest glaucoma, such as in those who have already undergone some functional or anatomic testing by optometrists, the best measures of GDx, HRT and OCT would miss about 60 cases out of the 200 patients with glaucoma, and would incorrectly refer 50 out of 800 patients without glaucoma. If prevalence were 5%, e.g. such as in people referred only because of family history of glaucoma, the corresponding figures would be 15 patients missed out of 50 with manifest glaucoma, avoiding referral of about 890 out of 950 non-glaucomatous people.Heterogeneity investigations found that sensitivity estimate was higher for studies with more severe glaucoma, expressed as worse average mean deviation (MD): 0.79 (0.74 to 0.83) for MD < -6 db versus 0.64 (0.60 to 0.69) for MD ≥ -6 db, at a similar summary specificity (0.93, 95% CI 0.92 to 0.94 and, respectively, 0.94; 95% CI 0.93 to 0.95; P < 0.0001 for the difference in relative DOR). AUTHORS' CONCLUSIONS: The accuracy of imaging tests for detecting manifest glaucoma was variable across studies, but overall similar for different devices. Accuracy may have been overestimated due to the case-control design, which is a serious limitation of the current evidence base.We recommend that further diagnostic accuracy studies are carried out on patients selected consecutively at a defined step of the clinical pathway, providing a description of risk factors leading to referral and bearing in mind the consequences of false positives and false negatives in the setting in which the diagnostic question is made. Future research should report accuracy for each threshold of these continuous measures, or publish raw data.


Assuntos
Glaucoma/diagnóstico , Fibras Nervosas/patologia , Oftalmoscopia/normas , Disco Óptico/patologia , Polarimetria de Varredura a Laser/normas , Tomografia de Coerência Óptica/normas , Erros de Diagnóstico/estatística & dados numéricos , Humanos , Razão de Chances , Estudos Prospectivos , Estudos Retrospectivos , Sensibilidade e Especificidade , Testes de Campo Visual
19.
BMC Ophthalmol ; 15: 175, 2015 Dec 11.
Artigo em Inglês | MEDLINE | ID: mdl-26654127

RESUMO

BACKGROUND: Spectral-domain optical coherence tomography (SD-OCT) provides fast scan speed and high scan resolution improving its diagnostic accuracy. The purpose of this study was to evaluate if SD-OCT measurements and their quality score are influenced by pupil dilation. METHODS: Retinal nerve fiber layer thickness (RNFL), ganglion cell complex (GCC) and optic nerve head (ONH) were measured in one eye of 57 glaucoma patients and 36 healthy subjects using spectral domain optical coherence tomography (SD-OCT) before and after pupil dilation. Comparisons were made between measurements and their quality score pre- and post dilation (Signal Strength Index, SSI). Overall RNFL, average GCC and ONH rim volume were considered in the analysis. RESULTS: No statistically significant differences were found between pre- and post-dilation measurements in both groups (glaucoma: RNFL 80 ± 15 µm vs 80 ± 16 µm, p = 0.87; GCC 81.35 ± 13.4 µm vs 81.10 ± 13.14 µm, p = 0.92; ONH 0.05 ± 0.11 mm(3) vs 0.04 ± 0.07 mm(3), p = 0.74; controls RNFL 99 ± 12 µm vs 98 ± 14 µm, p = 0.70; GCC 92.12 ± 6.7 µm vs 91.54 ± 7.05 µm, p = 0.72; ONH 0.11 ± 0.1 mm(3) vs 0.04 ± 0.07 mm(3), p = 0.36) nor between pre- and post-dilation quality score (glaucoma SSI RNFL 54.3 ± 10.3 vs 51.7 ± 18.1, p = 0.12; SSI GCC 58 ± 9.5 vs 57 ± 8.09, p = 0.55; SSI ONH 48.5 ± 7.6 vs 46.6 ± 7.2, p = 0.16; controls SSI RNFL 57 ± 10.3 vs 54 ± 9.31, p = 0.2; SSI GCC 60.9 ± 8.1 vs 58.8 ± 7.3, p = 0.3; SSI ONH 51.5 ± 8.9 vs 50.4 ± 8.3, p = 0.59). CONCLUSION: Pupil dilation doesn't affect SD-OCT measurements and their quality score.


Assuntos
Glaucoma/diagnóstico , Midriáticos/administração & dosagem , Fibras Nervosas/patologia , Disco Óptico/patologia , Pupila/efeitos dos fármacos , Células Ganglionares da Retina/patologia , Tomografia de Coerência Óptica/normas , Idoso , Feminino , Humanos , Pressão Intraocular , Masculino , Pessoa de Meia-Idade , Doenças do Nervo Óptico/diagnóstico , Tropicamida/administração & dosagem
20.
Int J Mol Sci ; 16(12): 28401-17, 2015 Nov 30.
Artigo em Inglês | MEDLINE | ID: mdl-26633368

RESUMO

Cytidine 5'-diphosphocholine or citicoline is an endogenous compound that acts in the biosynthetic pathway of phospholipids of cell membranes, particularly phosphatidylcholine, and it is able to increase neurotrasmitters levels in the central nervous system. Citicoline has shown positive effects in Parkinson's disease and Alzheimer's disease, as well as in amblyopia. Glaucoma is a neurodegenerative disease currently considered a disease involving ocular and visual brain structures. Neuroprotection has been proposed as a valid therapeutic option for those patients progressing despite a well-controlled intraocular pressure, the main risk factor for the progression of the disease. The aim of this review is to critically summarize the current evidence about the effect of citicoline in glaucoma.


Assuntos
Citidina Difosfato Colina/farmacologia , Citidina Difosfato Colina/uso terapêutico , Glaucoma/tratamento farmacológico , Animais , Sistema Nervoso Central/efeitos dos fármacos , Doenças do Sistema Nervoso Central/tratamento farmacológico , Doenças do Sistema Nervoso Central/etiologia , Citidina Difosfato Colina/química , Olho/efeitos dos fármacos , Glaucoma/etiologia , Glaucoma/metabolismo , Humanos , Pressão Intraocular/efeitos dos fármacos , Fármacos Neuroprotetores/farmacologia , Fármacos Neuroprotetores/uso terapêutico , Soluções Oftálmicas/farmacologia , Soluções Oftálmicas/uso terapêutico , Células Ganglionares da Retina/efeitos dos fármacos , Células Ganglionares da Retina/metabolismo
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa