Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
ACS Biomater Sci Eng ; 6(3): 1476-1486, 2020 03 09.
Artigo em Inglês | MEDLINE | ID: mdl-33455399

RESUMO

Functional integration of implanted biomaterials and bioengineered tissues in vivo requires effective and timely vascular ingrowth. While many vascularization strategies rely on delivery of angiogenic growth factors or endothelial cells to promote vascular ingrowth, the effect of physical and architectural features of biomaterials on the vascularization process is less well understood. Microchannels are a simple, accessible architectural feature frequently engineered into 3D biomaterials to promote mass transfer. In this study, the effect of microchannels on the integration and vascularization of 3D porous silk scaffolds was explored over a 14 week period. An array of 508 µm diameter microchannels spanning the length of critically sized, porous silk scaffolds significantly improved tissue ingrowth into the constructs. At week 6, all silk scaffolds (n = 8) with microchannels showed complete tissue infiltration throughout the construct, while only one of eight (12.5%) did so in the absence of microchannels. The presence of microchannels improved silk scaffold vascularization with significantly more vessels per unit area in the presence of microchannels. The vessel size distribution was similar in both scaffold types, but a shift in distribution toward smaller vessels was observed in the presence of microchannels. The blood vessels in silk scaffolds were perfused, functional and connected to the animal's cardiovascular system, as demonstrated by the presence of red blood cells in the vessel lumens, and effective delivery of a contrast agent the vessels inside the scaffold. This study demonstrates the utility of microchannels as a simple architectural feature that significantly improves vascularization and integration of implanted biomaterials.


Assuntos
Materiais Biocompatíveis , Seda , Animais , Sinais (Psicologia) , Células Endoteliais , Alicerces Teciduais
2.
Biomaterials ; 28(6): 947-55, 2007 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-17084445

RESUMO

Biocompatible, degradable hydrogel systems that can cure in situ following injection as a liquid are useful as a base for tissue engineering and drug delivery. In this study, poly (vinyl alcohol) (PVA) polymers were modified with degradable crosslinkers and formulated for either ultraviolet (UV) light initiation or chemical initiation using an oxidation/reduction (redox) curing method. A major objective was to compare the properties of degradable PVA hydrogels formed via two routes of curing. The effect of macromer concentration, degree of hydrolysis and functional group density on the degradation profiles was investigated. Also, since the hydrogels have been designed to be injected as a liquid for in situ curing, the effect of modified macromer solutions and degradation products on cell growth was investigated. Total degradation times ranged from approximately 20 days up to 120 days and increased in direct proportion with percent macromer. Initiation method (UV or redox) did not significantly impact on time for total degradation. While aqueous solutions of the modified macromer induced some cell growth inhibition, mainly associated with oxidative solutions, degradation products showed relatively low cell growth inhibition. Degradable PVA hydrogels tailored to produce networks with various degradation profiles can be cured by redox initiation and have potential as injectable polymers for soft-tissue engineering and drug delivery.


Assuntos
Materiais Biocompatíveis/administração & dosagem , Materiais Biocompatíveis/química , Fibroblastos/efeitos dos fármacos , Hidrogéis/administração & dosagem , Hidrogéis/química , Álcool de Polivinil/administração & dosagem , Álcool de Polivinil/química , Animais , Linhagem Celular , Proliferação de Células/efeitos dos fármacos , Sobrevivência Celular/efeitos dos fármacos , Reagentes de Ligações Cruzadas/química , Fibroblastos/citologia , Teste de Materiais , Camundongos , Oxirredução , Polímeros/química
3.
Biomaterials ; 25(20): 4887-900, 2004 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-15109849

RESUMO

The long-term biostability of a novel thermoplastic polyurethane elastomer (Elast-Eon 2 80A) synthesized using poly(hexamethylene oxide) (PHMO) and poly(dimethylsiloxane) (PDMS) macrodiols has been studied using an in vivo ovine model. The material's biostability was compared with that of three commercially available control materials, Pellethane 2363-80A, Pellethane 2363-55D and Bionate 55D, after subcutaneous implantation of strained compression moulded flat sheet dumbbells in sheep for periods ranging from 3 to 24 months. Scanning electron microscopy, attenuated total reflectance-Fourier transform infrared spectroscopy, and X-ray photoelectron spectroscopy were used to assess changes in the surface chemical structure and morphology of the materials. Gel permeation chromatography, differential scanning calorimetry and tensile testing were used to examine changes in bulk characteristics of the materials. The results showed that the biostability of the soft flexible PDMS-based test polyurethane was significantly better than the control material of similar softness, Pellethane 80A, and as good as or better than both of the harder commercially available negative control polyurethanes, Pellethane 55D and Bionate 55D. Changes observed in the surface of the Pellethane materials were consistent with oxidation of the aliphatic polyether soft segment and hydrolysis of the urethane bonds joining hard to soft segment with degradation in Pellethane 80A significantly more severe than that observed in Pellethane 55D. Very minor changes were seen on the surfaces of the Elast-Eon 2 80A and Bionate 55D materials. There was a general trend of molecular weight decreasing with time across all polymers and the molecular weights of all materials decreased at a similar relative rate. The polydispersity ratio, Mw/Mn, increased with time for all materials. Tensile tests indicated that UTS increased in Elast-Eon 2 80A and Bionate 55D following implantation under strained conditions. However, ultimate strain decreased and elastic modulus increased in the explanted specimens of all three materials when compared with their unimplanted unstrained counterparts. The results indicate that a soft, flexible PDMS-based polyurethane synthesized using 20% PHMO and 80% PDMS macrodiols has excellent long-term biostability compared with commercially available polyurethanes.


Assuntos
Materiais Biocompatíveis , Dimetilpolisiloxanos/química , Elastômeros/química , Polímeros , Poliuretanos/química , Silicones/química , Absorciometria de Fóton , Animais , Varredura Diferencial de Calorimetria , Cromatografia em Gel , Microscopia Eletrônica de Varredura , Peso Molecular , Ovinos , Espectroscopia de Infravermelho com Transformada de Fourier , Estresse Mecânico , Temperatura , Fatores de Tempo
4.
ASAIO J ; 56(6): 550-6, 2010.
Artigo em Inglês | MEDLINE | ID: mdl-21245802

RESUMO

Recent years have witnessed a rapid increase in the use of zirconium (Zr)-containing compounds in artificial internal organs. Examples include dental implants and other restorative practices, total knee and hip replacement, and middle-ear ossicular chain reconstruction. In nephrological practice, Zr-containing sorbents have been used in hemofiltration, hemodialysis, peritoneal dialysis, and in the design and construction of wearable artificial kidneys. Zr compounds continue to be widely and extensively used in deodorant and antiperspirant preparations. In the public health arena, Zr compounds have been studied or used in controlling phosphorus pollution and in the reclamation of poison and bacteria-contaminated water. Experimental and clinical studies support the general consensus that Zr compounds are biocompatible and exhibit low toxicity. Reports on possible Zr-associated adverse reactions are rare and, in general, have not rigorously established a cause-and-effect relationship. Although publications on the use of Zr compounds have continued to increase in recent years, reports on Zr toxicity have virtually disappeared from the medical literature. Nevertheless, familiarity with, and continued vigilant monitoring of, the use of these compounds are warranted. This article provides an updated review on the biomedical use of Zr compounds.


Assuntos
Materiais Biocompatíveis , Zircônio , Adsorção , Animais , Materiais Biocompatíveis/efeitos adversos , Materiais Biocompatíveis/farmacocinética , Materiais Biocompatíveis/uso terapêutico , Humanos , Osteomalacia/etiologia , Próteses e Implantes , Insuficiência Renal/terapia , Terapia de Substituição Renal/efeitos adversos , Terapia de Substituição Renal/métodos , Distribuição Tecidual , Purificação da Água/métodos , Zircônio/efeitos adversos , Zircônio/farmacocinética , Zircônio/uso terapêutico
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa