Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 91
Filtrar
1.
Strahlenther Onkol ; 200(1): 39-48, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37591978

RESUMO

PURPOSE: The geometric distortion related to magnetic resonance (MR) imaging in a diagnostic radiology (MRDR) and radiotherapy (MRRT) setup is evaluated, and the dosimetric impact of MR distortion on fractionated stereotactic radiotherapy (FSRT) in patients with brain metastases is simulated. MATERIALS AND METHODS: An anthropomorphic skull phantom was scanned using a 1.5­T MR scanner, and the magnitude of MR distortion was calculated with (MRDR-DC and MRRT-DC) and without (MRDR-nDC and MRRT-nDC) distortion-correction algorithms. Automated noncoplanar volumetric modulated arc therapy (HyperArc, HA; Varian Medical Systems, Palo Alto, CA, USA) plans were generated for 53 patients with 186 brain metastases. The MR distortion at each gross tumor volume (GTV) was calculated using the distance between the center of the GTV and the MR image isocenter (MIC) and the quadratic regression curve derived from the phantom study (MRRT-DC and MRRT-nDC). Subsequently, the radiation isocenter of the HA plans was shifted according to the MR distortion at each GTV (HADC and HAnDC). RESULTS: The median MR distortions were approximately 0.1 mm when the distance from the MIC was < 30 mm, whereas the median distortion varied widely when the distance was > 60 mm (0.23, 0.47, 0.37, and 0.57 mm in MRDR-DC, MRDR-nDC, MRRT-DC, and MRRT-nDC, respectively). The dose to the 98% of the GTV volume (D98%) decreased as the distance from the MIC increased. In the HADC plans, the relative dose difference of D98% was less than 5% when the GTV was located within 70 mm from the MIC, whereas the underdose of GTV exceeded 5% when it was 48 mm (-26.5% at maximum) away from the MIC in the HAnDC plans. CONCLUSION: Use of a distortion-correction algorithm in the studied MR diagnoses is essential, and the dosimetric impact of MR distortion is not negligible, particularly for tumors located far away from the MIC.


Assuntos
Neoplasias Encefálicas , Radiocirurgia , Humanos , Planejamento da Radioterapia Assistida por Computador/métodos , Radiocirurgia/métodos , Algoritmos , Neoplasias Encefálicas/diagnóstico por imagem , Neoplasias Encefálicas/radioterapia , Neoplasias Encefálicas/secundário , Imageamento por Ressonância Magnética/métodos , Dosagem Radioterapêutica
2.
Support Care Cancer ; 32(6): 391, 2024 May 29.
Artigo em Inglês | MEDLINE | ID: mdl-38806815

RESUMO

PURPOSE: This study focused on identifying the factors influencing the decision-making process in patients with localized prostate and cervical cancer in Japan and specifically examining the choice between surgery and radiotherapy. METHODS: Patients with specific cancer stages registered with a healthcare research company for whom radical surgery or radiotherapy was equally effective and recommended participated in this cross-sectional online survey. RESULTS: The responses of 206 and 231 patients with prostate and cervical cancer, respectively, revealed that both groups relied heavily on the physicians' recommendations (prostate: odds ratio (OR) = 40.3, p < 0.001; cervical: OR = 5.59, p < 0.001) and their impression of radiotherapy (prostate: OR = 9.22, p < 0.001; cervical: OR = 2.31, p < 0.001). Factors such as hypertension (OR = 6.48, p < 0.05), diabetes mellitus (OR = 9.68, p < 0.05), employment status (OR = 0.08, p < 0.01), and impressions of surgery (OR = 0.14, p < 0.01) also played a significant role in patients with prostate cancer. In contrast, the specialty of the physician (OR = 4.55, p < 0.05) proposing the treatment influenced the decision-making process of patients with cervical cancer. Information sources varied between the two groups: patients with prostate cancer were more inclined towards printed materials, whereas patients with cervical cancer were more inclined towards interpersonal relationships. CONCLUSION: Although several limitations, such as the sample and recall bias, were noted, this study emphasizes the role of psychosocial factors in the decision-making process and the requirement for tailored information sources.


Assuntos
Tomada de Decisões , Neoplasias da Próstata , Neoplasias do Colo do Útero , Humanos , Masculino , Neoplasias da Próstata/radioterapia , Neoplasias da Próstata/cirurgia , Estudos Transversais , Pessoa de Meia-Idade , Feminino , Neoplasias do Colo do Útero/radioterapia , Neoplasias do Colo do Útero/cirurgia , Idoso , Japão , Adulto , Inquéritos e Questionários
3.
J Appl Clin Med Phys ; : e14408, 2024 Jun 11.
Artigo em Inglês | MEDLINE | ID: mdl-38863310

RESUMO

PURPOSE: The study aimed to investigate the optimal isodose line (IDL) in linear accelerator-based stereotactic radiotherapy for single brain metastasis, using HyperArc. We compared the dosimetric parameters for target and normal brain tissue among six plans with different IDLs. METHODS: This study included 30 patients with single brain metastasis. We retrospectively generated six plans for each tumor with different IDLs (80%, 70%, 60%, 50%, 40%, and 33%) using HyperArc. All treatment plans were normalized to the prescription dose of 35 Gy in five fractions which was covered by 95% of the planning target volume (PTV), defined by adding a 1.0 mm margin to the gross tumor volume (GTV). The dosimetric parameters were compared among the six plans. RESULTS: For GTV > 0.1 cm3, the ratio of brain-GTV volumes receiving 25 Gy to PTV (V25Gy/PTV) was significantly lower at IDL 40%-70% than at IDL 80% and 33% (p < 0.01, retrospectively). For GTV < 0.1 cm3, V25Gy/PTV decreased continuously as IDL decreased. The values of D99% and D80% for GTV increased with decreasing IDL. An IDL of 50% or less was required to achieve D99% of greater than 43 Gy and D80% of greater than 50 Gy. The mean values of D99% and D80% for IDL 50% were 44.3 and 51.9 Gy. CONCLUSION: The optimal IDL is 40%-50% for GTV > 0.1 cm3. These lower IDLs could increase D99% and D80% of GTV while lowering V25Gy of normal brain tissue, which may help reduce the risk of radiation necrosis and improve local control.

4.
J Appl Clin Med Phys ; 25(6): e14294, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38319652

RESUMO

PURPOSE: To explore the potential of quantitative parameters of the hydrogel spacer distribution as predictors for separating the rectum from the planning target volume (PTV) in linear-accelerator-based stereotactic body radiotherapy (SBRT) for prostate cancer. METHODS: Fifty-five patients underwent insertion of a hydrogel spacer and were divided into groups 1 and 2 of the PTV separated from and overlapping with the rectum, respectively. Prescribed doses of 36.25-45 Gy in five fractions were delivered to the PTV. The spacer cover ratio (SCR) and hydrogel-implant quality score (HIQS) were calculated. RESULTS: Dosimetric and quantitative parameters of the hydrogel spacer distribution were compared between the two groups. For PTV, D99% in group 1 (n = 29) was significantly higher than that in group 2 (n = 26), and Dmax, D0.03cc, D1cc, and D10% for the rectum were significantly lower in group 1 than in group 2. The SCR for prostate (89.5 ± 12.2%) in group 1 was significantly higher (p < 0.05) than that in group 2 (74.7 ± 10.3%). In contrast, the HIQS values did not show a significant difference between the groups. An area under the curve of 0.822 (95% confidence interval, 0.708-0.936) for the SCR was obtained with a cutoff of 93.6%, sensitivity of 62.1%, and specificity of 100%. CONCLUSIONS: The SCR seems promising to predict the separation of the rectum from the PTV in linear-accelerator-based SBRT for prostate cancer.


Assuntos
Órgãos em Risco , Neoplasias da Próstata , Radiocirurgia , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador , Radioterapia de Intensidade Modulada , Humanos , Neoplasias da Próstata/radioterapia , Neoplasias da Próstata/cirurgia , Masculino , Radiocirurgia/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia de Intensidade Modulada/métodos , Órgãos em Risco/efeitos da radiação , Idoso , Aceleradores de Partículas/instrumentação , Hidrogéis/química , Pessoa de Meia-Idade , Prognóstico , Radiometria/métodos , Idoso de 80 Anos ou mais
5.
J Cancer Educ ; 2024 May 29.
Artigo em Inglês | MEDLINE | ID: mdl-38809493

RESUMO

Health literacy (HL) plays a vital role in an individual's ability to make informed health decisions. Japan faces several challenges in cervical cancer control, including low human papillomavirus (HPV) vaccination and screening rates, underutilization of radiotherapy, and limited HL. This study explored the association between HL and knowledge of cervical cancer and radiotherapy, particularly among young Japanese women. We conducted a web-based survey among users of LunaLuna, a popular women's healthcare application, to assess their HL and knowledge about cervical cancer and radiotherapy through a 46-question survey. We compared three groups in terms of HL (inadequate, problematic, and sufficient & excellent). Multiple regression analysis was used to identify factors associated with knowledge. In total, 1468 respondents were included in this study. HL was positively correlated with knowledge scores (inadequate: 51.8%; problematic: 56.3%; sufficient & excellent: 60%). Participants displayed relatively low accuracy for treatment-related questions. Higher HL (ß = 0.15, p < 0.01), education (ß = - 0.11, p < 0.01), cervical cancer screening (ß = - 0.11, p < 0.01), income (ß = 0.09, p < 0.01), and employment (ß = - 0.06, p = 0.04) were significant factors affecting knowledge of cervical cancer and radiotherapy. Our findings underscore the pivotal role of HL in promoting cervical cancer prevention and providing a better understanding of radiotherapy. Despite factors such as age, education, and history of cervical cancer screening, HL showed the strongest association with knowledge of cervical cancer and radiotherapy. The enhancement of HL and knowledge dissemination may be critical for promoting cervical cancer prevention and radiotherapy in Japan.

6.
J Appl Clin Med Phys ; 24(2): e13836, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-36333969

RESUMO

OBJECTIVE: Dosimetric potential of knowledge-based RapidPlan planning model trained with HyperArc plans (Model-HA) for brain metastases has not been reported. We developed a Model-HA and compared its performance with that of clinical volumetric modulated arc therapy (VMAT) plans. METHODS: From 67 clinical stereotactic radiosurgery (SRS) HyperArc plans for brain metastases, 47 plans were used to build and train a Model-HA. The other 20 clinical HyperArc plans were recalculated in RapidPlan system with Model-HA. The model performance was validated with the 20 plans by comparing dosimetric parameters for normal brain tissue between clinical plans and model-generated plans. The 20 clinical conventional VMAT-based SRS or stereotactic radiotherapy plans (CL-VMAT) were reoptimized with Model-HA (RP) and HyperArc system (HA), respectively. The dosimetric parameters were compared among three plans (CL-VMAT vs. RP vs. HA) in terms of planning target volume (PTV), normal brain excluding PTVs (Brain - PTV), brainstem, chiasm, and both optic nerves. RESULTS: In model validation, the optimization performance of Model-HA was comparable to that of HyperArc system. In comparison to CL-VMAT, there were no significant differences among three plans with respect to PTV coverage (p > 0.17) and maximum dose for brainstem, chiasm, and optic nerves (p > 0.40). RP provided significantly lower V20 Gy , V12 Gy , and V4 Gy for Brain - PTV than CL-VMAT (p < 0.01). CONCLUSION: The Model-HA has the potential to significantly reduce the normal brain dose of the original VMAT plans for brain metastases.


Assuntos
Neoplasias Encefálicas , Radiocirurgia , Radioterapia de Intensidade Modulada , Humanos , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador/métodos , Neoplasias Encefálicas/radioterapia , Neoplasias Encefálicas/cirurgia , Neoplasias Encefálicas/secundário , Encéfalo , Radiocirurgia/métodos , Radioterapia de Intensidade Modulada/métodos
7.
J Appl Clin Med Phys ; 23(4): e13536, 2022 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-35049125

RESUMO

PURPOSE: To compare the intrafractional motion error (IME) during stereotactic irradiation (STI) in patients with brain metastases immobilized using open- (Encompass) and full-face (DSPS) clamshell-style immobilization devices. METHODS: Encompass (38 patients) and DSPS (38 patients) were used for patient immobilization, and HyperArc plans with three to four non-coplanar beams were generated to deliver 25 to 35 Gy in three to five fractions. Cone-beam computed tomography (CBCT) was performed on patients before and after the treatment. Moreover, the difference in patient position between the two CBCT images was considered as the IME. The margins to compensate for IME were calculated using the van Herk margin formula. RESULTS: For Encompass, the mean values of IME in the translational setup were 0.1, 0.2, and 0.0 mm in the anterior-posterior, superior-inferior, and left-right directions, respectively, and the mean values of IME about rotational axes were -0.1, 0.0, and 0.0° for the Pitch, Roll, and Yaw rotations, respectively. For DSPS, the mean values of IME in the translational setup were 0.2, 0.2, and 0.0 mm in the anterior-posterior, superior-inferior, and left-right directions, respectively, and the mean values of IME about rotational axes were -0.1, -0.1, and 0.0° for the Pitch, Roll, and Yaw rotations, respectively. No statistically significant difference was observed between the IME of the two immobilization systems except in the anterior-posterior direction (p = 0.02). Moreover, no statistically significant correlation was observed between three-dimensional IME and treatment time. The margin compensation for IME was less than 1 mm for both immobilization devices. CONCLUSIONS: The IME during STI using open- and full-face clamshell-style immobilization devices is approximately equal considering the adequate accuracy in patient positioning.


Assuntos
Neoplasias Encefálicas , Radiocirurgia , Neoplasias Encefálicas/cirurgia , Tomografia Computadorizada de Feixe Cônico/métodos , Humanos , Imobilização , Posicionamento do Paciente , Radiocirurgia/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Erros de Configuração em Radioterapia/prevenção & controle
8.
J Appl Clin Med Phys ; 23(4): e13546, 2022 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-35112479

RESUMO

PURPOSE: This study introduced an A-mode portable ultrasound bladder scanner, the Lilium® α-200 (here after Lilium; Lilium Otsuka, Kanagawa, Japan), for the treatment of prostate cancer patients with hypofractionated volumetric modulated arc therapy to improve the reproducibility of bladder volume (BV). MATERIALS AND METHODS: Thirty patients were advised to maintain full BV prior to computed tomography (CT) simulation and daily treatment. Among these, the BV of 15 patients was measured using Lilium until a BV of 80% in the simulation was achieved (with the Lilium group). Daily cone-beam CT (CBCT) was performed for treatment. The correlation between BV measured by CBCT and Lilium was assessed. The differences in the BV and dosimetric parameters of the bladder in the CBCT versus planning CT were compared between the groups with and without Lilium. RESULTS: There was a significantly strong relationship (r = 0.796, p < 0.05) between the BVs measured using CBCT and Lilium. The relative BV ratios to simulation CT < 0.5 and > 2 were observed in 10.3% and 12.7%, respectively, of treatment sessions without Lilium group, while these ratios were 1% and 2.8%, respectively, in the Lilium group. The mean absolute difference in the range of V30Gy to V40Gy without Lilium sessions was significantly larger (p < 0.05) than that in the Lilium group. CONCLUSION: The use of the A-mode portable ultrasound bladder scanner significantly improved the reproducibility of the BV, resulting in few variations in the dosimetric parameters for the bladder.


Assuntos
Neoplasias da Próstata , Radioterapia de Intensidade Modulada , Tomografia Computadorizada de Feixe Cônico/métodos , Humanos , Masculino , Neoplasias da Próstata/diagnóstico por imagem , Neoplasias da Próstata/radioterapia , Planejamento da Radioterapia Assistida por Computador , Radioterapia de Intensidade Modulada/métodos , Reprodutibilidade dos Testes , Ultrassonografia , Bexiga Urinária/diagnóstico por imagem
9.
Rep Pract Oncol Radiother ; 27(5): 809-820, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36523803

RESUMO

Background: We evaluated the setup error and dose absorption of an immobilization system with a shell and wooden baseplate (SW) for lung stereotactic body radiotherapy (SBRT). Materials and methods: Setup errors in 109 patients immobilized with an SW or BodyFix system (BF) were compared. Dose attenuation rates of materials for baseplates were measured with an ion-chamber. Ionization measurements were performed from 90° to 180° gantry angle in 10° increments, with the ball water equivalent phantom placed at the center of the wood and carbon baseplates whose effects on dose distribution were compared using an electron portal imaging device. Results: The ratio for the anterior-posterior, cranial-caudal, and right-left of the cases within 3-mm registered shifts in interfractional setup error were 90.9%, 89.2%, and 97.4% for the SW, and 93.2%, 91.6%, and 98.0% for the BF, respectively. For intrafractional setup error, 98.3%, 97.4%, and 99.1% for the SW and 96.6%, 95.8%, and 98.7% for the BF were within 3-mm registered shifts, respectively. In the center position, the average (minimum/maximum) dose attenuation rates from 90° to 180° for the wooden and carbon baseplates were 0.5 (0.1/2.8)% and 1.0 (-0.1/10.1)% with 6 MV, respectively. The gamma passing rates of 2%/2 mm for the wooden and carbon baseplates were 99.7% and 98.3% (p < 0.01). Conclusions: The immobilization system with an SW is effective for lung SBRT since it is comparable to the BF in setup accuracy. Moreover, the wooden baseplate had lower radiation attenuation rates and affected the dose distribution less than the carbon baseplate.

10.
J Comput Assist Tomogr ; 45(1): 18-23, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-31738200

RESUMO

OBJECTIVES: The objective of this study was to assess the objective and subjective qualities of the contrast-enhanced 4-dimensional dual-energy computed tomography using adaptive statistical iterative reconstruction (ASiR) and ASiR-V. METHODS: The virtual monochromatic images at 60 keV were reconstructed using filtered back projection, ASiR, and ASiR-V (10%-100%) for 14 patients with pancreatic cancer. The contrast-to-noise ratio (CNR) was calculated, and the subjective measurements were compared based on a 5-point score scale. RESULTS: The ASiR-V yielded a significantly higher CNR than ASiR (P < 0.05). The subjective image quality (peak) was significantly improved (P < 0.01) with ASiR (50%) (3.8, 3.5, and 4.0; overall image quality, tumor delineation, and noise, respectively) and with ASiR-V (50%) (3.9, 3.5, and 4.2, respectively) compared with the filtered back projection (3.2, 3.2, and 3.0, respectively). CONCLUSIONS: The ASiR-V yielded higher CNR than ASiR and provided the highest subjective scores regarding the overall image quality.


Assuntos
Neoplasias Pancreáticas/diagnóstico por imagem , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Imagem Radiográfica a Partir de Emissão de Duplo Fóton/métodos , Idoso , Idoso de 80 Anos ou mais , Meios de Contraste , Feminino , Tomografia Computadorizada Quadridimensional , Humanos , Masculino , Pessoa de Meia-Idade
11.
J Appl Clin Med Phys ; 22(3): 254-260, 2021 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-33656261

RESUMO

PURPOSE: This study investigated the intra-fractional motion (IM) of patients immobilized using the QFix Encompass Immobilization System during HyperArc (HA) treatment. METHOD: HA treatment was performed on 89 patients immobilized using the Encompass. The IM during treatment (including megavoltage (MV) registration) was analyzed for six degrees of freedom including three axes of translation (anterior-posterior, superior-inferior (SI) and left-right (LR)) and three axes of rotation (pitch, roll, and yaw). Then, the no corrected IM (IMNC ) was retrospectively simulated (excluding MV registration) in three directions (SI, LR, and yaw). Finally, the correlation between the treatment time and the IM of the 3D vector was assessed. RESULTS: The average IM in terms of the absolute displacement were 0.3 mm (SI), 0.3 mm (LR) and 0.2° (yaw) for Stereotactic radiosurgery (SRS), and 0.3 mm (SI), 0.2 mm (LR), and 0.2° (yaw) for stereotactic radiotherapy (SRT). The absolute maximum values of IM were <1 mm along the SI and LR axes and <1° along the yaw axis. The absolute maximum displacements for IMNC were >1 mm along the SI and LR axes and >1° along the yaw axis. In the correlation between the treatment time and the IM, the r-values were -0.025 and 0.027 for SRS and SRT respectively, along the axes of translation. For the axes of rotation, the r-values were 0.012 and 0.206 for SRS and SRT, respectively. CONCLUSION: Encompass provided patient immobilization with adequate accuracy during HA treatment. The absolute maximum displacement IM was less than IMNC along the translational/rotational axes, and no statistically significant relationship between the treatment time and the IM was observed.


Assuntos
Neoplasias Encefálicas , Radiocirurgia , Neoplasias Encefálicas/radioterapia , Humanos , Imobilização , Posicionamento do Paciente , Planejamento da Radioterapia Assistida por Computador , Estudos Retrospectivos
12.
Rep Pract Oncol Radiother ; 26(2): 281-290, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34211779

RESUMO

BACKGROUND: The aim of the study was to evaluate analysis criteria for the identification of the presence of rectal gas during volumetric modulated arc therapy (VMAT) for prostate cancer patients by using electronic portal imaging device (EPID)-based in vivo dosimetry (IVD). MATERIALS AND METHODS: All measurements were performed by determining the cumulative EPID images in an integrated acquisition mode and analyzed using PerFRACTION commercial software. Systematic setup errors were simulated by moving the anthropomorphic phantom in each translational and rotational direction. The inhomogeneity regions were also simulated by the I'mRT phantom attached to the Quasar phantom. The presence of small and large air cavities (12 and 48 cm3) was controlled by moving the Quasar phantom in several timings during VMAT. Sixteen prostate cancer patients received EPID-based IVD during VMAT. RESULTS: In the phantom study, no systematic setup error was detected in the range that can happen in clinical (< 5-mm and < 3 degree). The pass rate of 2% dose difference (DD2%) in small and large air cavities was 98.74% and 79.05%, respectively, in the appearance of the air cavity after irradiation three quarter times. In the clinical study, some fractions caused a sharp decline in the DD2% pass rate. The proportion for DD2% < 90% was 13.4% of all fractions. Rectal gas was confirmed in 11.0% of fractions by acquiring kilo-voltage X-ray images after the treatment. CONCLUSIONS: Our results suggest that analysis criteria of 2% dose difference in EPID-based IVD was a suitable method for identification of rectal gas during VMAT for prostate cancer patients.

13.
Acta Oncol ; 59(3): 274-283, 2020 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-31755332

RESUMO

Background: This study aimed to evaluate knowledge-based volume modulated arc therapy (VMAT) plans for oesophageal cancers using a model trained with plans optimised with a different treatment planning system (TPS) and to compare lung dose sparing in two TPSs, Eclipse and RayStation.Materials and methods: A total of 64 patients with stage I-III oesophageal cancers were treated using hybrid VMAT (H-VMAT) plans optimised using RayStation. Among them, 40 plans were used for training the model for knowledge-based planning (KBP) in RapidPlan. The remaining 24 plans were recalculated using RapidPlan to validate the KBP model. H-VMAT plans calculated using RapidPlan were compared with H-VMAT plans optimised using RayStation with respect to planning target volume doses, lung doses, and modulation complexity.Results: In the lung, there were significant differences between the volume ratios receiving doses in excess of 5, 10, and 20 Gy (V5, V10, and V20). The V5 for the lung with H-VMAT plans optimised using RapidPlan was significantly higher than that of H-VMAT plans optimised using RayStation (p < .01), with a mean difference of 10%. Compared to H-VMAT plans optimised using RayStation, the V10 and V20 for the lung were significantly lower with H-VMAT plans optimised using RapidPlan (p = .04 and p = .02), with differences exceeding 1.0%. In terms of modulation complexity, the change in beam output at each control point was more constant with H-VMAT plans optimised using RapidPlan than with H-VMAT plans optimised using RayStation. The range of the change with H-VMAT plans optimised using RapidPlan was one third that of H-VMAT plans optimised using RayStation.Conclusion: Two optimisers in Eclipse and RayStation had different dosimetric performance in lung sparing and modulation complexity. RapidPlan could not improve low lung doses, however, it provided an appreciate intermediated doses compared to plans optimised with RayStation.


Assuntos
Neoplasias Esofágicas/radioterapia , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia de Intensidade Modulada/métodos , Humanos , Radiometria , Dosagem Radioterapêutica
14.
J Appl Clin Med Phys ; 21(11): 153-162, 2020 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-33058408

RESUMO

PURPOSE: To investigate the detectability of fiducial markers' positions for real-time target tracking system equipping with a standard linac. The hypothesis is that the detectability depends on the type of fiducial marker and the gantry angle of acquired triggered images. METHODS: Three types of ball fiducials and four slim fiducials with lengths of 3 and 5 mm were prepared for this study. Triggered images with three similar fiducials were acquired at every 10° during the conformal arc irradiation to detect the target position. Although only one type of arrangement was prepared for the ball fiducials, a three-type arrangement was prepared for the slim fiducials, such as parallel, orthogonal, and oblique with 45° to the gantry-couch direction. To measure the detectability of the real-time target tracking system for each fiducial and arrangement, detected marker positions were compared with expected marker positions at every angle of acquired triggered images. RESULTS: For the ball-type fiducial, the maximum difference between the detected marker positions and expected marker positions was 0.3 mm in all directions. For the slim fiducial arranged parallel and oblique with 45°, the maximum difference was 0.4 mm in all directions. When each slim fiducial was arranged orthogonal to the gantry-couch direction, the maximum difference was 1.5 mm for the length of 3 mm, and 3.2 mm for the length of 5 mm. CONCLUSIONS: The detectability of fiducial markers' positions for the real-time target tracking system equipping with a standard linac depends on the form and insertion angles of the fiducials.


Assuntos
Marcadores Fiduciais , Radioterapia Conformacional , Sistemas Computacionais , Humanos
15.
Rep Pract Oncol Radiother ; 25(5): 703-708, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32684857

RESUMO

BACKGROUND: We investigated the change of dose distributions in volumetric modulated arc therapy (VMAT) under baseline drift (BD) during breath holding. MATERIALS AND METHODS: Ten VMAT plans recalculated to a static field at a gantry angle of 0° were prepared for measurement with a 2D array device and five original VMAT plans were prepared for measurement with gafchromic films. These measurement approaches were driven by a waveform reproducing breath holding with BD. We considered breath holding times of 15 and 10 s, and BD at four speeds; specifically, BD0 (0 mm/s), BD0.2 (0.2 mm/s), BD0.3 (0.3 mm/s), and BD0.4 (0.4 mm/s). The BD was periodically reproduced from the isocenter along the craniocaudal direction and the shift during breath holding (ShiftBH) ranged 0-6 mm.The dose distribution of BD0.2, BD0.3 and BD0.4 were compared to that of BD0 using gamma analysis with the criterion of 2%/2 mm. RESULTS: The mean pass rates of each ShiftBH were 99.8% and 98.9% at 0 mm, 96.8% and 99.4% at 2 mm, 94.9% and 98.6% at 3 mm, 91.5% and 98.4% at 4 mm, 70.8% and 94.1% at 4.5 mm, and 55.0% and 83.6% at 6 mm for the array and film measurements, respectively. CONCLUSION: We found significant differences in ShiftBH above 4 mm (ρ < 0.05). Hence, it is recommended that breath holding time should be shortened for patients to preserve the reproducibility of dose distributions.

16.
Rep Pract Oncol Radiother ; 25(6): 1023-1028, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-33390859

RESUMO

BACKGROUND: The aim of this study was to clarify factors predicting the performance of knowledge-based planning (KBP) models in volume modulated arc therapy for prostate cancer in terms of sparing the organ at risk (OAR). MATERIALS AND METHODS: In three institutions, each KBP model was trained by more than 20 library plans (LP) per model. To validate the characterization of each KBP model, 45 validation plans (VP) were calculated by the KBP system. The ratios of overlap between the OAR volume and the planning target volume (PTV) to the whole organ volume (Voverlap/Vwhole) were analyzed for each LP and VP. Regression lines between dose-volume parameters (V90, V75, and V50) and Voverlap/Vwhole were evaluated. The mean OAR dose, V90, V75, and V50 of LP did not necessarily match those of VP. RESULTS: In both the rectum and bladder, the dose-volume parameters for VP were strongly correlated with Voverlap/Vwhole at institutes A, B, and C (R > 0.74, 0.85, and 0.56, respectively). Except in the rectum at institute B, the slopes of the regression lines for LP corresponded to those for VP. For dose-volume parameters for the rectum, the ratios of slopes of the regression lines in VP to those in LP ranged 0.51-1.26. In the bladder, most ratios were less than 1.0 (mean: 0.77). CONCLUSION: For each OAR, each model made distinct dosimetric characterizations in terms of Voverlap/Vwhole. The relationship between dose-volume parameters and Voverlap/Vwhole of OARs in LP predicts the KBP models' performance sparing OARs.

17.
J Appl Clin Med Phys ; 20(10): 84-91, 2019 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-31507075

RESUMO

PURPOSE: In stereotactic radiosurgery (SRS) with single-isocentric treatments for brain metastases, rotational setup errors may cause considerable dosimetric effects. We assessed the dosimetric effects on HyperArc plans for single and multiple metastases. METHODS: For 29 patients (1-8 brain metastases), HyperArc plans with a prescription dose of 20-24 Gy for a dose that covers 95% (D95% ) of the planning target volume (PTV) were retrospectively generated (Ref-plan). Subsequently, the computed tomography (CT) used for the Ref-plan and cone-beam CT acquired during treatments (Rot-CT) were registered. The HyperArc plans involving rotational setup errors (Rot-plan) were generated by re-calculating doses based on the Rot-CT. The dosimetric parameters between the two plans were compared. RESULTS: The dosimetric parameters [D99% , D95% , D1% , homogeneity index, and conformity index (CI)] for the single-metastasis cases were comparable (P > 0.05), whereas the D95% for each PTV of the Rot-plan decreased 10.8% on average, and the CI of the Rot-plan was also significantly lower than that of the Ref-plan (Ref-plan vs Rot-plan, 0.93 ± 0.02 vs 0.75 ± 0.14, P < 0.01) for the multiple-metastases cases. In addition, for the multiple-metastases cases, the Rot-plan resulted in significantly higher V10Gy (P = 0.01), V12Gy (P = 0.02), V14Gy (P = 0.02), and V16Gy (P < 0.01) than those in the Ref-plan. CONCLUSION: The rotational setup errors for multiple brain metastases cases caused non-negligible underdosage for PTV and significant increases of V10Gy to V16Gy in SRS with HyperArc.


Assuntos
Neoplasias Encefálicas/secundário , Neoplasias Encefálicas/cirurgia , Radiocirurgia/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Erros de Configuração em Radioterapia/prevenção & controle , Radioterapia de Intensidade Modulada/métodos , Humanos , Órgãos em Risco/efeitos da radiação , Dosagem Radioterapêutica , Estudos Retrospectivos
18.
J Appl Clin Med Phys ; 20(11): 144-152, 2019 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-31633869

RESUMO

Virtual monochromatic images (VMIs) at a lower energy level can improve image quality but the computed tomography (CT) number of iodine contained in the contrast-enhanced agent is dramatically increased. We assessed the effect of the use of contrast-enhanced agent on the dose distributions in volumetric modulated arc therapy (VMAT) planning for head and neck cancer (HNC). Based on the VMIs at 40 keV (VMI40keV ), 60 keV(VMI60keV ), and 77 keV (VMI77keV ) of a tissue characterization phantom, lookup tables (LUTs) were created. VMAT plans were generated for 15 HNC patients based on contrast-enhanced- (CE-) VMIs at 40-, 60-, and 77 keV using the corresponding LUTs, and the doses were recalculated based on the noncontrast-enhanced- (nCE-) VMIs. For all structures, the difference in CT numbers owing to the contrast-enhanced agent was prominent as the energy level of the VMI decreased, and the mean differences in CT number between CE- and nCE-VMI was the largest for the clinical target volume (CTV) (125.3, 55.9, and 33.1 HU for VMI40keV , VMI60keV , and VMI77keV, respectively). The mean difference of the dosimetric parameters (D99% , D50% , D1% , Dmean , and D0.1cc ) for CTV and OARs was <1% in the treatment plans based on all VMIs. The maximum difference was observed for CTV in VMI40keV (2.4%), VMI60keV (1.9%), and VMI77keV (1.5%) plans. The effect of the contrast-enhanced agent was larger in the VMAT plans based on the VMI at a lower energy level for HNC patients. This effect is not desirable in a treatment planning procedure.


Assuntos
Meios de Contraste , Neoplasias de Cabeça e Pescoço/radioterapia , Imagens de Fantasmas , Garantia da Qualidade dos Cuidados de Saúde/normas , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia de Intensidade Modulada/métodos , Humanos , Processamento de Imagem Assistida por Computador/métodos , Órgãos em Risco/efeitos da radiação , Dosagem Radioterapêutica , Tomografia Computadorizada por Raios X/métodos
19.
J Comput Assist Tomogr ; 42(6): 965-971, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30252833

RESUMO

OBJECTIVE: The aim of the study was to compare the accuracy of quantification of iodine and Hounsfield unit (HU) values on virtual monochromatic imaging (VMI) using dual-layer computed tomography (DLCT) and fast kilovolt-switching computed tomography (FKSCT). MATERIALS AND METHODS: This study was performed in 2 phantoms (large and small) using 16 rods representing different materials (iodine, calcium, blood, and adipose tissue) with different dimensions and concentrations. The absolute percentage errors (absolute ratio of measurement error to true iodine concentration) for iodine concentration and HU value on VMI at 50, 70, and 100 keV were compared between DLCT and FKSCT. The Mann-Whitney U test was used to assess statistical significance. RESULTS: Overall, the absolute percentage errors for iodine concentration and HU value on VMI were smaller for DLCT than for FKSCT. CONCLUSIONS: Overall, the accuracy of iodine and HU values was higher for DLCT than for FKSCT.


Assuntos
Meios de Contraste/química , Iodo/química , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Imagem Radiográfica a Partir de Emissão de Duplo Fóton/métodos , Tomografia Computadorizada por Raios X/métodos , Imagens de Fantasmas
20.
J Comput Assist Tomogr ; 42(4): 655-660, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29613989

RESUMO

OBJECTIVE: The objective of this study was to assess the accuracy of the quantitative measurements obtained using dual-energy computed tomography with metal artifact reduction software (MARS). METHODS: Dual-energy computed tomography scans (fast kV-switching) are performed on a phantom, by varying the number of metal rods (Ti and Pb) and reference iodine materials. Objective and subjective image analyses are performed on retroreconstructed virtual monochromatic images (VMIs) (VMI at 70 keV). RESULTS: The maximum artifact indices for VMI-Ti and VMI-Pb (5 metal rods) with MARS (without MARS) were 17.4 (166.7) and 34.6 (810.6), respectively; MARS significantly improved the mean subjective 5-point score (P < 0.05). The maximum differences between the measured Hounsfield unit and theoretical values for 5 mg/mL iodine and 2-mm core rods were -42.2% and -68.5%, for VMI-Ti and VMI-Pb (5 metal rods), respectively, and the corresponding differences in the iodine concentration were -64.7% and -73.0%, respectively. CONCLUSIONS: Metal artifact reduction software improved the objective and subjective image quality; however, the quantitative values were underestimated.


Assuntos
Artefatos , Processamento de Imagem Assistida por Computador/métodos , Iodo/farmacocinética , Imagens de Fantasmas , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/métodos , Metais , Imagem Radiográfica a Partir de Emissão de Duplo Fóton/métodos , Reprodutibilidade dos Testes
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa