Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Endocrine ; 85(1): 321-330, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38460071

RESUMO

PURPOSE: Measurement of cortisol concentrations is method dependent. The study aimed to establish assay-specific cut-off limits for cortisol after adrenocorticotropic hormone (ACTH) stimulation, comparing Roche Elecsys Cortisol II immunoassay to liquid chromatography-mass spectrometry (LC-MS/MS), and to assess the impact of patient characteristics, estrogen containing oral contraceptives as well as relation to other adrenocortical steroid hormone dynamics. METHODS: One hundred healthy participants underwent a 250 µg ACTH-test, with plasma samples analyzed using ElecsysCortI, ElecsysCortII, and LC-MS/MS. Cortisone, corticosterone, 17-OH-progesterone, dehydroepiandrosterone sulfate (DHEAS), androstenedione, and testosterone were additionally analyzed with LC-MS/MS. Cut-off limit for a normal cortisol response to the ACTH-test was defined as: 2.5th percentile-1.96 × SE. RESULTS: ElecsysCort II measured cortisol concentrations 21% (95% CI: 19-22%) lower than ElecsysCort I. Cut-off limits for cortisol 30 and 60 min after ACTH were 426 and 485 nmol/L (ElecsysCort II) and 411 and 470 nmol/L (LC-MS/MS). Cut-offs were unaffected by gender, or body-composition. The ACTH-test resulted in significantly increased adrenocortical steroid hormones, except for decreased cortisone concentrations (both sexes), and decreased testosterone in men (1.9 nmol/L, 95% CI: 1.3-2.5). Testosterone was increased in women (0.07 nmol/L, 95% CI: 0.02-0.13). CONCLUSION: ElecsysCort II has high analytical performance and yields significantly lower cortisol concentrations than prior polyclonal immunoassays. This clinically relevant difference underscores the necessity for revised cut-off limits for improved diagnostic precision. Suggested 30-minute cortisol cutoff limits are 411 nmol/L (LC-MS/MS) and 426 nmol/L (ElecsysCort II). Adrenocortical steroids increased upon ACTH stimulation, except for cortisone in both sexes and testosterone in men, both of which decreased.


Assuntos
Hormônio Adrenocorticotrópico , Hidrocortisona , Espectrometria de Massas em Tandem , Humanos , Hidrocortisona/sangue , Hormônio Adrenocorticotrópico/sangue , Feminino , Masculino , Adulto , Espectrometria de Massas em Tandem/métodos , Imunoensaio/métodos , Cromatografia Líquida/métodos , Pessoa de Meia-Idade , Testosterona/sangue , Adulto Jovem , Cortisona/sangue , Valores de Referência , Sulfato de Desidroepiandrosterona/sangue , Espectrometria de Massa com Cromatografia Líquida
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa