Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 27
Filtrar
1.
Echocardiography ; 39(11): 1420-1425, 2022 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-36258636

RESUMO

INTRODUCTION: Effect of transcatheter edge-to-edge repair (TEER) using MitraClip in patients with mitral regurgitation (MR) on left atrial (LA) kinetic energy (LAKE), an index of LA work, and LA strain, a measure of LA performance, have not been well defined. METHODS: Patients with chronic primary or secondary 3+ or 4+ MR were analyzed pre- and post-TEER using MitraClip. LAKE was determined by echocardiography using LA stroke volume and A-wave velocity. Peak atrial longitudinal strain (PALS), peak atrial strain in early diastole, and peak atrial contraction strain (PACS) were obtained by speckle tracking echocardiography. RESULTS: Thirty-nine patients undergoing TEER with MitraClip were screened, 12 met criteria for analysis (9 primary and 3 secondary MR). Compared to pre-TEER, there was a significant increase post-TEER in LAKE (71.0 ± 64.1 vs. 177.5 ± 167.9 dyne·cm·103 , respectively; p = .008) and Doppler transmitral A-wave velocity (87.8 ± 41.4 vs. 138.5 ± 43.7 cm/s, respectively; p < .001); LA stroke volume did not change significantly. Mitral valve mean gradient significantly increased post-TEER compared to pre-TEER (5.7 ± 2.1 vs. 3.3 ± 2.1 mmHg, respectively; p = .01). There was a trend toward decrease in PALS post-TEER compared to pre-TEER (16.2 ± 4.8 vs. 20.7 ± 9.9%, respectively; p = .05). Peak atrial strain in early diastole significantly decreased post-TEER compared to pre-TEER (7.2 ± 3.0 vs. 14.1 ± 7.2%; respectively, p < .001), while PACS did not significantly change (9.1 ± 3.5 vs. 6.7 ± 5.2%, respectively; p = .07). CONCLUSION: In patients with chronic MR, LAKE increases after TEER with MitraClip driven by an increase in LA emptying velocities. Changes were also seen in LA strain with MitraClip. These procedurally induced changes due to mild mitral stenosis may have clinical implications.


Assuntos
Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Mitral , Humanos , Insuficiência da Valva Mitral/complicações , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/cirurgia , Valva Mitral/diagnóstico por imagem , Função do Átrio Esquerdo , Átrios do Coração/diagnóstico por imagem , Ecocardiografia , Resultado do Tratamento
2.
Heart Fail Clin ; 15(2): 305-320, 2019 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-30832820

RESUMO

Treatment of patients with heart failure with reduced ejection fraction has evolved. Recently, a fully implantable remote hemodynamic monitoring sensor in the pulmonary artery was approved in the treatment of patients at risk of heart failure readmissions. Several novel devices designed to offload the left atrium by creating a small interatrial shunt are being investigated. Cardiac imaging plays a vital role in the selection process, implantation, and monitoring of individuals with such devices. This article discusses in detail various imaging techniques and key clinical points relating to several cardiac devices used in the treatment of patients with heart failure.


Assuntos
Técnicas de Imagem Cardíaca/métodos , Insuficiência Cardíaca/cirurgia , Ventrículos do Coração/diagnóstico por imagem , Coração Auxiliar/efeitos adversos , Cateterismo Cardíaco/métodos , Oxigenação por Membrana Extracorpórea/efeitos adversos , Insuficiência Cardíaca/diagnóstico por imagem , Humanos
3.
Echocardiography ; 35(1): 4-8, 2018 01.
Artigo em Inglês | MEDLINE | ID: mdl-28942598

RESUMO

BACKGROUND AND AIM: Exposure to workplace radiation among cardiac sonographers has been felt to be low, and patient-related sources have been considered negligible. Sonographers may be exposed to radiation from patient emitted sources as well as external sources in interventional laboratories. This study quantified radiation exposure to cardiac sonographers. METHODS: Cardiac sonographers, vascular imaging technologists, exercise physiologists, noninvasive nursing staff, and CT/MRI technologists were provided body dosimeter badges. Sonographers were provided dosimeter rings for their scanning hands. Radiation exposure was quantified from the dosimeter data, reported in millirems (mrem) for deep, eye, and shallow exposure, as well as shallow exposure data from the rings. Data were prospectively collected for 63 employees over a 12-month period and retrospectively analyzed. RESULTS: The mean annual deep body exposure in sonographers was 8.2 mrem/year, shallow exposure 9.8 mrem/year, eye exposure 8.5 mrem/year, and ring exposure 207 mrem/year. There was a significant difference between body and ring exposure (P = .0002). When comparing exposure data between the vascular imaging technologists, CT/MRI technologists, noninvasive nursing staff, and the cardiac sonographers, there were no statistical differences (P > .23). Exercise physiologists had significantly higher exposure compared to sonographers (P < .03). CONCLUSION: This single-center experience demonstrates that, while exposure is low, cardiac sonographers are exposed to workplace radiation, most likely from patient emitted radiation. The finding that radiation exposure from rings exceeded body exposure supports this conclusion. Continued education and assessment of work flow practices should be employed to minimize staff radiation exposure.


Assuntos
Centros Médicos Acadêmicos , Ecocardiografia , Pessoal de Laboratório Médico/estatística & dados numéricos , Exposição Ocupacional/estatística & dados numéricos , Doses de Radiação , Exposição à Radiação/estatística & dados numéricos , Coração/diagnóstico por imagem , Humanos , Laboratórios , Ohio , Estudos Prospectivos , Dosímetros de Radiação/estatística & dados numéricos , Estudos Retrospectivos , Medição de Risco
4.
J Ultrasound Med ; 37(2): 397-402, 2018 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-28786137

RESUMO

OBJECTIVES: Accreditation of echocardiographic testing facilities by the Intersocietal Accreditation Commission (IAC) is supported by the American College of Cardiology and American Society of Echocardiography. However, limited information exists on the accreditation status and geographic distribution of echocardiographic facilities in the United States. Our study aimed to identify (1) the proportion of outpatient echocardiography facilities used by Medicare beneficiaries that are IAC accredited, (2) their geographic distribution, and (3) variations in procedure type and volume by accreditation status. METHODS: As part of the VALUE-ECHO (Value of Accreditation, Location, and Utilization Evaluation-Echocardiography) study, we examined the proportion of IAC-accredited echocardiographic facilities performing outpatient echocardiography in the 2013 Centers for Medicare and Medicaid Services outpatient limited data set (100% sample) and their geographic distribution using geocoding in ArcGIS (ESRI, Redlands, CA). RESULTS: Among 4573 outpatient facilities billing Medicare for echocardiographic testing in 2013, 99.6% (n = 4554) were IAC accredited (99.7% in the 50 US states and 86.2% in Puerto Rico). The proportion IAC-accredited echocardiographic facilities varied by region, with 98.7%, 99.9%, 99.9%, 99.5%, and 86.2% of facilities accredited in the Northeast, South, Midwest, West, and Puerto Rico, respectively (P < .01, Fisher exact test). Of all echocardiographic outpatient procedures conducted (n = 1,890,156), 99.8% (n = 1,885,382) were performed in IAC-accredited echocardiographic facilities. Most procedures (90.9%) were transthoracic echocardiograms, of which 99.7% were conducted in IAC-accredited echocardiographic facilities. CONCLUSIONS: Almost all outpatient echocardiographic facilities billed by Medicare are IAC accredited. This accreditation rate is substantially higher than previously reported for US outpatient vascular testing facilities (13% IAC accredited). The uniformity of imaging and interpretation protocols from a single accrediting body is important to facilitate optimal cardiovascular care.


Assuntos
Acreditação/estatística & dados numéricos , Ecocardiografia , Acessibilidade aos Serviços de Saúde/estatística & dados numéricos , Medicare , Pacientes Ambulatoriais , Geografia , Humanos , Estados Unidos
5.
Echocardiography ; 30(10): E304-6, 2013 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-23937587

RESUMO

Aneurysms of the coronary arteries are rare and are usually associated with atherosclerosis in adults. Mycotic coronary artery aneurysms are exceedingly uncommon and are typically associated with systemic bacteremia, endocarditis, or septic emboli. Literature and data describing the management of mycotic coronary artery aneurysms are limited. This case describes the successful diagnosis of a large right coronary artery aneurysm by transesophageal echocardiogram as well as the successful management of the aneurysm.


Assuntos
Aneurisma Infectado/diagnóstico , Aneurisma Roto/diagnóstico , Aneurisma Coronário/diagnóstico , Endocardite/diagnóstico , Adulto , Alcinos/uso terapêutico , Aneurisma Infectado/cirurgia , Aneurisma Roto/cirurgia , Bacteriemia/complicações , Cateterismo Cardíaco , Aneurisma Coronário/cirurgia , Vasos Coronários/diagnóstico por imagem , Ecocardiografia Transesofagiana , Endocardite/tratamento farmacológico , Átrios do Coração/diagnóstico por imagem , Cardiopatias/complicações , Cardiopatias/diagnóstico por imagem , Ventrículos do Coração/diagnóstico por imagem , Humanos , Falência Renal Crônica/complicações , Masculino , Pericardite/etiologia , Peritonite/complicações , Doenças Raras , Infecções Estreptocócicas/complicações , Infecções Estreptocócicas/microbiologia , Trombose/complicações , Trombose/diagnóstico por imagem
6.
J Invasive Cardiol ; 34(6): E442-E447, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-35652707

RESUMO

OBJECTIVES: In patients with transcatheter aortic valve implantation (TAVI), accurate assessment of gradients is important to assess valve function and durability, which drives clinical decision-making. We sought to evaluate discrepancies in aortic valve mean gradients with balloon-expandable and self-expanding TAVI. METHODS: We retrospectively reviewed 507 patients that underwent TAVI and compared mean gradients by catheterization to transthoracic Doppler echocardiography. RESULTS: Mean gradients by Doppler in balloon-expandable (11.0 ± 5.8 mm Hg) and self-expanding devices (8.7 ± 4.5 mm Hg) were significantly higher than catheterization (3.2 ± 4.0 mm Hg vs 3.5 ± 4.1 mm Hg, respectively; P<.001). In a subgroup analysis of skirted valves, Doppler gradients in balloon-expandable (9.8 ± 4.4 mm Hg) and self-expanding devices (8.6 ± 5.1 mm Hg) were significantly higher than catheterization (3.5 ± 4.1 mm Hg vs 4.2 ± 4.8 mm Hg, respectively; P<.001). When the effect of valve size on gradients was analyzed, Doppler gradients were significantly higher than catheterization for all comparisons. When indexed for valve size, patients with large aortas who received a balloon-expandable TAVI had greater pressure differential than those who received a self-expanding TAVI (8.24 ± 0.46 mm Hg vs 5.16 ± 0.66 mm Hg; P<.001). This trend was not seen in patients with a small aorta-to-valve index. CONCLUSION: Following TAVI, aortic valve mean gradients acquired by Doppler were higher than catheterization and the discrepancy was more pronounced in balloon-expandable than self-expanding prostheses. These differences persist in skirted valves and across valve sizes. These observations may reflect periprocedural hemodynamic changes, differences between prosthetic flow acceleration, and/or pressure recovery.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/cirurgia , Cateterismo , Ecocardiografia , Humanos , Desenho de Prótese , Estudos Retrospectivos , Resultado do Tratamento
7.
Int J Stroke ; 16(5): 519-525, 2021 07.
Artigo em Inglês | MEDLINE | ID: mdl-33040698

RESUMO

We report on the natural history of a cohort of patients presenting with transient ischemic attack or stroke and nonbacterial thrombotic endocarditis treated with warfarin.Patients with valvular vegetations on echocardiography, stroke, or transient ischemic attack presenting to a single neurologist were included. All patients were treated with warfarin until the vegetation resolved or for two years, then were switched to aspirin and had at least one clinical and echocardiographic follow-up.Twenty-nine patients were included and followed for a median of 27 months. Average age was 42 years and 72% were female. Two patients had vegetations on two valves. Five patients (17%) had recurrent strokes, three had systemic lupus erythematosus and antiphospholipid antibodies, one had antiphospholipid antibodies alone and one had neither condition. Three of the five patients did not have resolution of the vegetation at the time of the event. The valvular vegetations resolved in 23 of the 31 affected valves (74%) after a median of 11 months (range 4.5-157.5). Eleven patients had at least one follow-up echocardiogram after resolution of the vegetation and none had recurrent vegetations after warfarin was stopped.This study should serve to provide general recommendations regarding treatment of patients with TIA/stroke with nonbacterial thrombotic endocarditis. Valvular vegetations resolve in most patients and the risk of recurrent stroke is low. Warfarin can safely be switched to aspirin in most patients when the vegetation resolves or after two years if it does not resolve. Prolonged warfarin may be warranted in patients with systemic lupus erythematosus, positive antiphospholipid antibodies, and a persistent vegetation.


Assuntos
Endocardite , Lúpus Eritematoso Sistêmico , Acidente Vascular Cerebral , Adulto , Ecocardiografia , Endocardite/tratamento farmacológico , Feminino , Humanos , Acidente Vascular Cerebral/tratamento farmacológico , Varfarina/uso terapêutico
8.
Echocardiography ; 27(2): E27-9, 2010 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-20380674

RESUMO

A 47-year-old man presented with chest pain and was found to have an ascending aortic dissection. He underwent aortic arch resection and replacement with a hemishield tube graft with a valve conduit, better known as the Bentall technique. Five months later he presented with shortness of breath. A transesophageal echocardiogram revealed near-complete dehiscence of the mechanical valve conduit and a periaortic root abscess. He underwent removal of the conduit and placement of a homograft aortic root and valve. One month later he developed rigors. A transthoracic echocardiogram showed worsening systolic function and a periaortic hematoma or abscess. Serial transthoracic echocardiograms revealed increasing size in the periaortic echogenic free space and subsequent evidence of flow from the left ventricle into the periaortic space. He was determined not to be a surgical candidate and discharged to hospice in fair condition. He subsequently expired.


Assuntos
Aneurisma Aórtico/complicações , Aneurisma Aórtico/cirurgia , Dissecção Aórtica/complicações , Dissecção Aórtica/cirurgia , Aortite/etiologia , Aortite/cirurgia , Prótese Vascular/efeitos adversos , Remoção de Dispositivo , Humanos , Masculino , Pessoa de Meia-Idade , Resultado do Tratamento
9.
Cardiovasc Revasc Med ; 21(12): 1606-1612, 2020 12.
Artigo em Inglês | MEDLINE | ID: mdl-32461047

RESUMO

Secondary (also known as functional) mitral regurgitation (MR) has increased substantially over the last several decades due to an increase in the prevalence of dilated cardiomyopathy (ischemic and non-ischemic). Mortality and morbidity in patients with dilated cardiomyopathy is much greater when associated with MR as compared to without MR. MR will result in further left ventricular (LV) volume overload, LV dilation, and pupillary muscle displacement resulting in deterioration of the severity of MR leading to a vicious cycle. Optimization of heart failure medical therapy, and cardiac resynchronization therapy for those that qualify, can improve severity of MR; however, significant MR will persist in certain patients. Transcatheter mitral valve repair to treat significant MR using the MitraClip (Abbott, Menlo Park, California), which grasps and coapts the posterior and anterior mitral valve leaflets, in appropriately selected patients with dilated cardiomyopathy and secondary MR has been shown to improve quality of life and prolong survival.


Assuntos
Insuficiência Cardíaca , Insuficiência da Valva Mitral , Implante de Prótese de Valva Cardíaca , Humanos , Valva Mitral/cirurgia , Insuficiência da Valva Mitral/cirurgia , Qualidade de Vida , Resultado do Tratamento
10.
Mayo Clin Proc ; 95(1): 69-76, 2020 01.
Artigo em Inglês | MEDLINE | ID: mdl-31902431

RESUMO

OBJECTIVE: To assess the impact of stroke volume index (SVI) and left ventricular ejection fraction (LVEF) on prognosis in patients with severe aortic stenosis, comparing those undergoing transcatheter aortic valve replacement (TAVR) and those with surgical AVR (SAVR). PATIENTS AND METHODS: A total of 742 patients from the CoreValve US Pivotal High-Risk Trial randomized to TAVR (n=389) or SAVR (n=353) from February 2011 to September 2012 were stratified by an SVI of 35 mL/m2 and LVEF of 50% for comparing all-cause mortality at 1 year. RESULTS: The prevalence of an SVI of less than 35 mL/m2 in patients who underwent TAVR and SAVR was 35.8% (125 of 349) and 31.3% (96 of 307), respectively; LVEF of less than 50% was present in 18.1% (63 of 348) and 19.6% (60 of 306), respectively. Among patients with an SVI of less than 35 mL/m2, 1-year mortality was similar between patients with TAVR and SAVR (16.3% vs 22.2%; P=.25). However, in those with an SVI of 35 mL/m2 or greater, 1-year mortality was lower in those with TAVR than SAVR (10.3% vs 17.3%; P=.03). In patients with an LVEF of less than 50%, mortality was not affected by AVR approach (P>.05). In patients with an LVEF of 50% or higher, TAVR was associated with lower mortality than SAVR when SVI was preserved (9.8% vs 18.6%; P=.01). Mortality was not affected by SVI within the same AVR approach when LVEF was 50% or higher. CONCLUSION: In patients with severe aortic stenosis at high risk, there is a significant interaction between AVR approach and the status of SVI and LVEF. When LVEF or SVI was reduced, prognosis was similar regardless of AVR approach. In those with preserved LVEF or SVI, TAVR was associated with a better prognosis than SAVR. TRIAL REGISTRATION: clinicaltrials.gov Identifier: NCT01240902.


Assuntos
Estenose da Valva Aórtica , Implante de Prótese de Valva Cardíaca , Volume Sistólico , Substituição da Valva Aórtica Transcateter , Função Ventricular Esquerda , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/mortalidade , Estenose da Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/cirurgia , Correlação de Dados , Feminino , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/métodos , Implante de Prótese de Valva Cardíaca/estatística & dados numéricos , Humanos , Masculino , Prognóstico , Estudos Retrospectivos , Medição de Risco/métodos , Fatores de Risco , Índice de Gravidade de Doença , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/métodos , Substituição da Valva Aórtica Transcateter/estatística & dados numéricos , Resultado do Tratamento
11.
Aorta (Stamford) ; 6(3): 75-80, 2018 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-30208492

RESUMO

BACKGROUND: Floppy mitral valve/mitral valve prolapse (FMV/MVP), a heritable disorder of connective tissue, often leads to mitral regurgitation (MR) and is the most common cause for mitral valve surgery in developed countries. Connective tissue disorders may affect aortic function, and a stiff aorta may increase the severity of MR. Aortic function, however, has not been studied in FMV/MVP with MR. METHODS: A total of 17 patients (11 men, 6 women) with FMV/MVP and significant MR were compared with 20 controls matched for age and gender. Aortic diameters (AoD) were measured from left ventriculograms at 2 and 4 cm above the aortic valve. Aortic pressures were measured directly using fluid-filled catheters. Aortic distensibility was calculated using the formula: 2(systolic AoD-diastolic AoD)/(diastolic AoD x pulse pressure). RESULTS: Aortic distensibility was significantly lower in FMV/MVP compared with control at 2 cm above the aortic valve (1.00 ± 0.19 versus 3.78 ± 1.10 10-3 mm Hg-1, respectively; p = 0.027) and 4 cm above the aortic valve (0.89 ± 0.16 versus 3.22 ± 0.19 10-3 mm Hg-1, respectively; p = 0.007). FMV/MVP patients had greater left ventricular (LV) end-systolic (88 ± 72 mL versus 35 ± 15 mL, p = 0.002) and end-diastolic (165 ± 89 mL versus 100 ± 41 mL, p = 0.005) volumes, and lower LV ejection fraction, compared with control (50 ± 12% versus 57 ± 6%, p = 0.034). CONCLUSION: Aortic distensibility is decreased (consistent with a stiff aorta) in patients with FMV/MVP and MR. A stiff aorta may increase the severity of MR. Thus, abnormal aortic function, which also deteriorates with age, may play an important role in the natural history of MR due to FMV/MVP.

12.
Am J Cardiol ; 121(7): 867-873, 2018 04 01.
Artigo em Inglês | MEDLINE | ID: mdl-29454478

RESUMO

The prediction of cancer therapeutics-related cardiac dysfunction (CTRCD) is an essential aspect of care for individuals who receive potentially cardiotoxic oncologic treatments. Certain clinical risk factors have been described for incident CTRCD, and measurement of left ventricular (LV) longitudinal strain by speckle tracking 2-dimensional echocardiography (2DE) is the best-validated myocardial mechanical imaging assessment to detect subtle changes in LV function during cancer treatment. However, the direct integration of clinical and imaging risk factors to predict CTRCD has not yet been extensively examined. This was a retrospective study of 183 women with breast cancer aged 50.9 ± 10.8 years who received treatment with anthracyclines (doxorubicin dose of 422 ± 69 mg/m2, with 41.2% of subjects also receiving trastuzumab) and underwent 2DE at clinically determined intervals. CTRCD was diagnosed when LV ejection fraction dropped ≥10% to a subnormal (<53%) value by 2DE. Left ventricular global longitudinal strain (LV-GLS) was assessed offline. The risk prediction tool based only on clinical factors previously described by Ezaz et al was applied to our cohort and accurately stratified these subjects into low-, intermediate-, and high-risk groups, with incident CTRCD in 7.4%, 26.9%, and 54.6%, respectively (chi-square = 20.7, p <0.0001). We developed novel multivariate models to predict CTRCD using (1) demographic variables only (c = 0.8674), (2) echocardiographic (peak LV-GLS) variables only (c = 0.8440), or (3) a combination of demographic and echocardiographic variables, with the combined model exhibiting superior receiver-operating characteristics (c = 0.9629). In conclusion, estimation of CTRCD risk should integrate all available data, including both clinical variables and an imaging assessment.


Assuntos
Antibióticos Antineoplásicos/efeitos adversos , Neoplasias da Mama/tratamento farmacológico , Doxorrubicina/efeitos adversos , Insuficiência Cardíaca/epidemiologia , Disfunção Ventricular/epidemiologia , Adulto , Antraciclinas/efeitos adversos , Antineoplásicos Imunológicos/uso terapêutico , Fibrilação Atrial/epidemiologia , Flutter Atrial/epidemiologia , Doença da Artéria Coronariana/epidemiologia , Diabetes Mellitus/epidemiologia , Ecocardiografia , Feminino , Humanos , Hipertensão/epidemiologia , Modelos Logísticos , Pessoa de Meia-Idade , Insuficiência Renal/epidemiologia , Reprodutibilidade dos Testes , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Volume Sistólico , Trastuzumab/uso terapêutico , Disfunção Ventricular/induzido quimicamente
13.
J Card Fail ; 13(4): 304-11, 2007 May.
Artigo em Inglês | MEDLINE | ID: mdl-17517351

RESUMO

BACKGROUND: Cardiac resynchronization therapy (CRT) improves echocardiographic measures of ventricular structure and function in the failing heart. To determine whether or not these changes are representative of true biologic reverse ventricular remodeling or simply an artifact of an improved contraction pattern, we evaluated changes in myocardial gene expression typical of reverse remodeling before and after chronic CRT. METHODS AND RESULTS: Optimally medically treated patients with nonischemic heart failure meeting standard clinical criteria for CRT were enrolled. Before implantation of a CRT device, baseline echocardiogram and endomyocardial biopsies were obtained. These studies were repeated after 6 months of CRT. Using quantitative reverse-transcriptase polymerase chain reaction, the amount of messenger RNA for selected genes regulating contractile function (sarcoplasmic reticulum Ca2+ ATPase, alpha- and beta-myosin heavy chain [MHC] isoforms, phospholamban [PLB]), and pathologic hypertrophy (beta-MHC and atrial natriuretic peptide [ANP]) was determined from biopsy samples. Changes in gene expression (baseline to 6 months) were determined and correlated to changes in echocardiographic remodeling parameters. Ten patients were enrolled in the study, with 7 completing both baseline and follow-up biopsies and echocardiograms. On average, a significant increase was observed in alpha-MHC and PLB gene expression from baseline to 6 months (P = .016 for both). Beta-MHC levels tended to decrease with CRT (P = .078). Increased alpha-MHC levels correlated best with decreases in left ventricular end-diastolic dimension (P = .073, r = -0.71) and reductions in mitral regurgitation. No significant correlation between ejection fraction and gene expression was found. CONCLUSIONS: These changes in myocardial gene expression support the occurrence of reverse remodeling during chronic CRT. The changes are similar to those reported previously with beta-blockade, but were seen on top of standard drug therapies for heart failure.


Assuntos
Estimulação Cardíaca Artificial , Cardiomiopatia Dilatada/genética , Cardiomiopatia Dilatada/terapia , Expressão Gênica , Miocárdio/metabolismo , Adulto , Idoso , Cardiomiopatia Dilatada/diagnóstico , Cardiomiopatia Dilatada/metabolismo , Feminino , Perfilação da Expressão Gênica/métodos , Humanos , Masculino , Pessoa de Meia-Idade , Miocárdio/patologia , Remodelação Ventricular/genética
15.
Am Heart J ; 151(2): 380-9, 2006 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-16442904

RESUMO

BACKGROUND: Electrical cardioversion in patients with atrial fibrillation (AF) is associated with an increased risk of stroke. We compared a transesophageal echocardiography (TEE)-guided strategy with a conventional strategy in patients with AF > 2 days' duration undergoing electrical cardioversion over a 6-month follow-up. METHODS: The ACUTE study was a multicenter, randomized, clinical trial, with 1222 patients. Six-month follow-up was available in 1034 patients (85%), 525 in the TEE group and 509 in the conventional group. The primary composite end points were cerebrovascular accident, transient ischemic attack, and peripheral embolism at 6 months, which was a prespecified time point. Secondary end points were hemorrhage, mortality, and sinus rhythm. RESULTS: At 6 months, there was no difference in composite embolic events between the TEE group and the conventional group (10 [2%] vs 4 [0.8%]; risk ratio (RR) 2.47, 95% CI 0.78-7.88; P = .11). However, the hemorrhagic rate was significantly lower in the TEE group (23 [4.4%] vs 38 [7.5%]; RR 0.58, 96% CI 0.35-0.97; P = .04). There was no difference between the 2 treatment groups in all-cause mortality (21 [4%] vs 14 [2.8%]; RR 1.48, 95% CI 0.76-2.92; P = .25) and in the occurrence of normal sinus rhythm between the 2 groups (305 [62.2%] vs 280 [58.1%]; P = .51). Sinus rhythm at 6 months was more common in the TEE-guided group, in those patients who had direct current cardioversion (238 [62.5%] vs 151 [53.9%]; P = .03). CONCLUSION: The TEE-guided strategy may be considered a clinically effective alternative to a conventional anticoagulation strategy for patients with AF of > 2 days' duration undergoing electrical cardioversion over a 6-month period.


Assuntos
Anticoagulantes/uso terapêutico , Fibrilação Atrial/terapia , Ecocardiografia Transesofagiana , Cardioversão Elétrica/métodos , Embolia/etiologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Fibrilação Atrial/mortalidade , Embolia/mortalidade , Feminino , Hemorragia/etiologia , Humanos , Ataque Isquêmico Transitório/etiologia , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Acidente Vascular Cerebral/etiologia , Resultado do Tratamento , Ultrassonografia de Intervenção/métodos
16.
Artigo em Inglês | MEDLINE | ID: mdl-27313280

RESUMO

BACKGROUND: The CoreValve US High-Risk Clinical Study compared clinical outcomes and serial echocardiographic findings in patients with severe aortic valve stenosis after transcatheter aortic valve replacement (TAVR) with a self-expanding bioprosthesis or surgical aortic valve replacement (SAVR). METHODS AND RESULTS: Eligible patients were randomly assigned 1:1 to TAVR with a self-expanding bioprosthesis or SAVR (N=747). Echocardiograms were obtained at baseline, discharge, 30 days, 6 months, and 1 year after the procedure and were analyzed at a central core laboratory. Compared with SAVR patients (N=357), TAVR patients (N=390) had a lower mean aortic valve gradient, larger valve area, and less patient-prosthesis mismatch (all P<0.001), but more paravalvular regurgitation at discharge, which decreased at 1 year. SAVR patients experienced significant right ventricular systolic dysfunction at discharge and 1 month with normal right ventricular function at 1 year. One-year all-cause mortality was 14.2% for TAVR and 19.1% for SAVR patients. Preimplantation aortic regurgitation ≥mild was associated with reduced mortality hazard for both the TAVR (hazard ratio 0.48, 95% confidence interval 0.27-0.85; P=0.01) and the SAVR groups (hazard ratio 0.53, 95% confidence interval 0.32-0.87; P=0.01). Aortic regurgitation ≥mild after TAVR was associated with increased risk for all-cause mortality (hazard ratio 1.95, 95% confidence interval 1.08-3.53; P=0.03). CONCLUSIONS: In patients with severe aortic stenosis at increased surgical risk, TAVR was associated with better systolic valve performance, similar left ventricular remodeling, more paravalvular regurgitation, and less right ventricular systolic dysfunction compared with SAVR. Despite an overall mortality reduction for the TAVR group, ≥mild aortic valve regurgitation after TAVR was associated with an increased mortality hazard. CLINICAL TRIAL REGISTRATION: URL: http://www.clinicaltrials.gov. Unique identifier: NCT01240902.


Assuntos
Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Ecocardiografia Doppler , Implante de Prótese de Valva Cardíaca/instrumentação , Próteses Valvulares Cardíacas , Desenho de Prótese , Substituição da Valva Aórtica Transcateter/instrumentação , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Insuficiência da Valva Aórtica/diagnóstico por imagem , Insuficiência da Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/mortalidade , Estenose da Valva Aórtica/fisiopatologia , Feminino , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/mortalidade , Hemodinâmica , Humanos , Masculino , Valor Preditivo dos Testes , Medição de Risco , Fatores de Risco , Índice de Gravidade de Doença , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/mortalidade , Resultado do Tratamento , Estados Unidos , Função Ventricular Esquerda , Função Ventricular Direita , Remodelação Ventricular
17.
Am J Cardiol ; 94(9): 1192-6, 2004 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-15518621

RESUMO

Systolic and diastolic time intervals were measured in 11 patients with heart failure before and 1 and 3 months after the placement of atrial biventricular pacemakers for cardiac resynchronization therapy (CRT). CRT shortened the preejection period, principally by reducing left ventricular (LV) electromechanical delay with lesser reduction of isovolumic contraction time, and shortened the duration of LV systole, with a consequent trend of lengthening diastolic time.


Assuntos
Insuficiência Cardíaca/terapia , Marca-Passo Artificial , Idoso , Bloqueio de Ramo/etiologia , Estimulação Cardíaca Artificial , Eletrocardiografia , Feminino , Seguimentos , Sistema de Condução Cardíaco/fisiopatologia , Sistema de Condução Cardíaco/cirurgia , Insuficiência Cardíaca/fisiopatologia , Frequência Cardíaca/fisiologia , Humanos , Masculino , Pessoa de Meia-Idade , Contração Miocárdica/fisiologia , Complicações Pós-Operatórias/etiologia , Volume Sistólico/fisiologia , Fatores de Tempo , Resultado do Tratamento , Disfunção Ventricular Esquerda/fisiopatologia , Disfunção Ventricular Esquerda/terapia
18.
J Am Soc Echocardiogr ; 17(11): 1204-6, 2004 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-15502799

RESUMO

We report the case of a 30-year-old man with acute pericarditis in whom effusive-constrictive physiology developed rapidly in less than 2 weeks. Serial echocardiography demonstrated a dramatic change in the appearance of the pericardial effusion and the pericardial space. The patient underwent pericardiectomy with symptom relief. The findings at operation included a markedly thickened and inflamed pericardium. The case highlights the role of echocardiography in the evaluation of patients with pericardial disease and the echocardiographic features that prompted early surgical intervention.


Assuntos
Ecocardiografia/métodos , Derrame Pericárdico/diagnóstico por imagem , Pericardite Constritiva/diagnóstico por imagem , Adulto , Terapia Combinada , Diagnóstico Diferencial , Humanos , Masculino , Derrame Pericárdico/terapia , Pericardite Constritiva/terapia
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa