Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
1.
Anal Chem ; 85(9): 4770-6, 2013 May 07.
Artigo em Inglês | MEDLINE | ID: mdl-23534536

RESUMO

We report here on a new potentiometric biosensing principle for the detection of antibody-antigen interactions at the sensing membrane surface without the need to add a label or a reporter ion to the sample solution. This is accomplished by establishing a steady-state outward flux of a marker ion from the membrane into the contacting solution. The immunobinding event at the sensing surface retards the marker ion, which results in its accumulation at the membrane surface and hence in a potential response. The ion-selective membranes were surface-modified with an antibody against respiratory syncytial virus using click chemistry between biotin molecules functionalized with a triple bond and an azide group on the modified poly (vinyl chloride) group of the membrane. The bioassay sensor was then built up with streptavidin and subsequent biotinylated antibody. A quaternary ammonium ion served as the marker ion. The observed potential was found to be modulated by the presence of respiratory syncytial virus bound on the membrane surface. The sensing architecture was confirmed with quartz crystal microbalance studies, and stir effects confirmed the kinetic nature of the marker release from the membrane. The sensitivity of the model sensor was compared to that of a commercially available point-of-care test, with promising results.


Assuntos
Anticorpos/química , Técnicas Biossensoriais/métodos , Vírus Sinciciais Respiratórios/química , Reações Antígeno-Anticorpo , Técnicas Biossensoriais/instrumentação , Eletrodos , Potenciometria/instrumentação , Propriedades de Superfície
2.
J Magn Reson ; 190(2): 189-99, 2008 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-18023218

RESUMO

Diffusion weighted magnetic resonance imaging enables the visualization of fibrous tissues such as brain white matter. The validation of this non-invasive technique requires phantoms with a well-known structure and diffusion behavior. This paper presents anisotropic diffusion phantoms consisting of parallel fibers. The diffusion properties of the fiber phantoms are measured using diffusion weighted magnetic resonance imaging and bulk NMR measurements. To enable quantitative evaluation of the measurements, the diffusion in the interstitial space between fibers is modeled using Monte Carlo simulations of random walkers. The time-dependent apparent diffusion coefficient and kurtosis, quantifying the deviation from a Gaussian diffusion profile, are simulated in 3D geometries of parallel fibers with varying packing geometries and packing densities. The simulated diffusion coefficients are compared to the theory of diffusion in porous media, showing a good agreement. Based on the correspondence between simulations and experimental measurements, the fiber phantoms are shown to be useful for the quantitative validation of diffusion imaging on clinical MRI-scanners.


Assuntos
Mapeamento Encefálico/métodos , Imagem de Difusão por Ressonância Magnética/métodos , Imagens de Fantasmas , Algoritmos , Anisotropia , Água Corporal/metabolismo , Simulação por Computador , Processamento de Imagem Assistida por Computador , Imageamento Tridimensional , Método de Monte Carlo , Fibras Nervosas
3.
Phys Med Biol ; 53(19): 5405-19, 2008 Oct 07.
Artigo em Inglês | MEDLINE | ID: mdl-18765890

RESUMO

Diffusion weighted magnetic resonance imaging offers a non-invasive tool to explore the three-dimensional structure of brain white matter in clinical practice. Anisotropic diffusion hardware phantoms are useful for the quantitative validation of this technique. This study provides guidelines on how to manufacture anisotropic fibre phantoms in a reproducible way and which fibre material to choose to obtain a good quality of the diffusion weighted images. Several fibre materials are compared regarding their effect on the diffusion MR measurements of the water molecules inside the phantoms. The diffusion anisotropy influencing material properties are the fibre density and diameter, while the fibre surface relaxivity and magnetic susceptibility determine the signal-to-noise ratio. The effect on the T(2)-relaxation time of water in the phantoms has been modelled and the diffusion behaviour inside the fibre phantoms has been quantitatively evaluated using Monte Carlo random walk simulations.


Assuntos
Imagem de Difusão por Ressonância Magnética/métodos , Difusão , Imagens de Fantasmas , Anisotropia , Imagem de Difusão por Ressonância Magnética/instrumentação , Magnetismo , Reprodutibilidade dos Testes , Propriedades de Superfície , Fatores de Tempo , Água/química
4.
J Appl Physiol (1985) ; 103(5): 1736-43, 2007 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-17690198

RESUMO

Carnosine (beta-alanyl-l-histidine) is present in high concentrations in human skeletal muscle. The ingestion of beta-alanine, the rate-limiting precursor of carnosine, has been shown to elevate the muscle carnosine content. We aimed to investigate, using proton magnetic resonance spectroscopy (proton MRS), whether oral supplementation with beta-alanine during 4 wk would elevate the calf muscle carnosine content and affect exercise performance in 400-m sprint-trained competitive athletes. Fifteen male athletes participated in a placebo-controlled, double-blind study and were supplemented orally for 4 wk with either 4.8 g/day beta-alanine or placebo. Muscle carnosine concentration was quantified in soleus and gastrocnemius by proton MRS. Performance was evaluated by isokinetic testing during five bouts of 30 maximal voluntary knee extensions, by endurance during isometric contraction at 45% maximal voluntary contraction, and by the indoor 400-m running time. beta-Alanine supplementation significantly increased the carnosine content in both the soleus (+47%) and gastrocnemius (+37%). In placebo, carnosine remained stable in soleus, while a small and significant increase of +16% occurred in gastrocnemius. Dynamic knee extension torque during the fourth and fifth bout was significantly improved with beta-alanine but not with placebo. Isometric endurance and 400-m race time were not affected by treatment. In conclusion, 1) proton MRS can be used to noninvasively quantify human muscle carnosine content; 2) muscle carnosine is increased by oral beta-alanine supplementation in sprint-trained athletes; 3) carnosine loading slightly but significantly attenuated fatigue in repeated bouts of exhaustive dynamic contractions; and 4) the increase in muscle carnosine did not improve isometric endurance or 400-m race time.


Assuntos
Carnosina/metabolismo , Suplementos Nutricionais , Exercício Físico/fisiologia , Contração Muscular/efeitos dos fármacos , Fadiga Muscular/efeitos dos fármacos , Músculo Esquelético/efeitos dos fármacos , Resistência Física/efeitos dos fármacos , beta-Alanina/farmacologia , Administração Oral , Bélgica , Método Duplo-Cego , Humanos , Contração Isométrica/efeitos dos fármacos , Espectroscopia de Ressonância Magnética , Masculino , Músculo Esquelético/metabolismo , Corrida , Análise e Desempenho de Tarefas , Fatores de Tempo , beta-Alanina/administração & dosagem
5.
Phys Med Biol ; 52(23): 6781-94, 2007 Dec 07.
Artigo em Inglês | MEDLINE | ID: mdl-18029975

RESUMO

Carnosine has been shown to be present in the skeletal muscle and in the brain of a variety of animals and humans. Despite the various physiological functions assigned to this metabolite, its exact role remains unclear. It has been suggested that carnosine plays a role in buffering in the intracellular physiological pHi range in skeletal muscle as a result of accepting hydrogen ions released in the development of fatigue during intensive exercise. It is thus postulated that the concentration of carnosine is an indicator for the extent of the buffering capacity. However, the determination of the concentration of this metabolite has only been performed by means of muscle biopsy, which is an invasive procedure. In this paper, we utilized proton magnetic resonance spectroscopy (1H MRS) in order to perform absolute quantification of carnosine in vivo non-invasively. The method was verified by phantom experiments and in vivo measurements in the calf muscles of athletes and untrained volunteers. The measured mean concentrations in the soleus and the gastrocnemius muscles were found to be 2.81 +/- 0.57/4.8 +/- 1.59 mM (mean +/- SD) for athletes and 2.58 +/- 0.65/3.3 +/- 0.32 mM for untrained volunteers, respectively. These values are in agreement with previously reported biopsy-based results. Our results suggest that 1H MRS can provide an alternative method for non-invasively determining carnosine concentration in human calf muscle in vivo.


Assuntos
Algoritmos , Carnosina/análise , Espectroscopia de Ressonância Magnética/métodos , Músculo Esquelético/metabolismo , Humanos , Prótons , Coxa da Perna , Distribuição Tecidual
6.
Phys Med Biol ; 49(20): 4765-83, 2004 Oct 21.
Artigo em Inglês | MEDLINE | ID: mdl-15566174

RESUMO

In this study, a direct, fast image reconstruction algorithm, based on the fact that equipotential lines are perpendicular to current lines in a volume conductor, is proposed for magnetic resonance electrical impedance tomography (MR-EIT). The proposed technique is evaluated both on simulated and measured data for conductor and insulator objects.


Assuntos
Algoritmos , Impedância Elétrica , Interpretação de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Imageamento por Ressonância Magnética/instrumentação , Imagens de Fantasmas , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Tomografia
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa